[email protected] +44 (0)1661 830101 +44 (0)1661 897454 www.sealedtightsolutions.com Units 1b - 1d, Princess Court, Prudhoe, Northumberland. NE42 6NP. SEALED TIGHT SOLUTIONS fire & smoke :16 STS 4001 12" Fire-rated letter-plate (inc. 30mm x 2mm intumescent liner) All STS acoustic data is sourced, supplied and verified by independent, UKAS-accredited test facilities in accordance with all relevant British and European standards. fire, smoke & acoustic test data BS 9999 BS 476: 22 - 1987 BS 8214 - 2008 BS EN 1634 - 1: 2008 (t) (°C) 20 40 60 80 100 120 140 800 600 400 200 ‘B’ ‘M’ (Fire Safety) (Access To and Use of Buildings) Approved Document Approved Document BS EN 1634 - 3: 2004 BS 476: 31 - 1 BS EN 13724: 2002 BS EN 1670: CLASS 5 125 315 800 2000 5000 Frequency (Hz) 10 20 30 40 50 60 Sound Reduction Index (dB) Rw Ref. Curve Sound Reduction Index (dB) STS 4001 “FRAME / FLAP” Characteristics / features Product code Material(s) Compliant FIRE ACOUSTIC DURABILITY ROYAL MAIL SALT SPRAY Standard: Frame: ABS (UV safe) Flap: DIE-CAST ZINC Premium:Frame: Frame: DIE-CAST ZINC Flap: DIE-CAST ZINC Standard Finish - Painted Gold - Painted Silver - White - Chrome (mirrored) - Satin - Polished Gold G S W CH SAT PG BK / BK / BK / BK / BK / BK / Premium - Chrome (mirrored) - Satin - Polished Gold CH / CH SAT / SAT PG / PG IMPORTANT! See page 2 for Fitting Instructions

Untitled-1 [sealedtightsolutions.com]sealedtightsolutions.com/Datasheet/STS-4001-Letterplates.pdf · Title: Untitled-1 Author: Garry Created Date: 20180809171132Z

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Untitled-1 [sealedtightsolutions.com]sealedtightsolutions.com/Datasheet/STS-4001-Letterplates.pdf · Title: Untitled-1 Author: Garry Created Date: 20180809171132Z

[email protected]+44 (0)1661 830101 +44 (0)1661 897454 www.sealedtightsolutions.comUnits 1b - 1d, Princess Court, Prudhoe, Northumberland. NE42 6NP.

SEALED TIGHT SOLUTIONS

fire &s moke

:16STS 4001 12" Fire-rated letter-plate (inc. 30mm x 2mm intumescent liner)

All STS acoustic data is sourced, supplied and verified by independent, UKAS-accredited test facilities

in accordance with all relevant British and European standards.

fire, smoke & acoustic test data

BS 9999

BS 476: 22 - 1987

BS 8214 - 2008

BS EN 1634 - 1: 2008(t)

(°C)

20 40 60 80 100 120 140

800

600

400

200

‘B’‘M’

(Fire Safety)(Access To and Use of Buildings)

Approved DocumentApproved Document

BS EN 1634 - 3: 2004BS 476: 31 - 1

BS EN 13724: 2002

BS EN 1670: CLASS 5125 315 800 2000 5000

Frequency (Hz)

10

20

30

40

50

60

Soun

d R

educ

tion

Inde

x (d

B)

Rw Ref. Curve

Sound Reduction Index (dB)

STS 4001 “FRAME / FLAP”

Characteristics / features

Product code Material(s) Compliant

FIREACOUSTICDURABILITYROYAL MAILSALT SPRAY

Standard:Frame: ABS (UV safe)Flap: DIE-CAST ZINC

Premium:Frame:Frame: DIE-CAST ZINCFlap: DIE-CAST ZINC

Standard

Finish

- Painted Gold- Painted Silver- White- Chrome (mirrored)- Satin- Polished Gold

GSWCHSATPG

BK /BK /BK /BK /BK /BK /

Premium

- Chrome (mirrored)- Satin- Polished Gold

CH / CHSAT / SATPG / PG

IMPORTANT!

See page 2 for Fitting Instructions

Page 2: Untitled-1 [sealedtightsolutions.com]sealedtightsolutions.com/Datasheet/STS-4001-Letterplates.pdf · Title: Untitled-1 Author: Garry Created Date: 20180809171132Z

SEALED TIGHT SOLUTIONS

fire &s moke

:16STS 4001 12" Fire-rated letter-plate (inc. 30mm x 2.5mm intumescent liner)

FITTING INSTRUCTIONS

IMPORTANT!

The STS 4001 comes with a 1 metre long, 30mm wide, self-adhesive, intumescent liner.ALL of the liner MUST be used when fitting.

NOTE: The liner is positioned on the INNER SLEEVE. (SEE IMAGE)

Once the liner is securely fitted, apply a thin bead of silicone mastic around the reverse face of the inner sleeve. (SEE IMAGE)Fit the inner sleeve into the pre-prepared aperture. (from the INSIDE of the door)Apply a thin bead of silicone mastic around the weather seal fitted to the reverse face of the outer sleeve. (SEE IMAGE) Fit the outer sleeve (from the OUTSIDE of the door) so it locates into the inner sleeve.Fix the inner and outer sleeves with 4no. 30mm x 4mm screws (not supplied). (SEE IMAGE)

Secure the STS 4001 with the 2no. main fixing screws as provided.

FRONT/REAR VIEW - STS 4001 INSIDE/OUTSIDE (FLAP CLOSED) OUTER SLEEVE

TOP VIEW - OUTSIDE SLEEVE (FLAP CLOSED)

FRONT VIEW - STS 4001 INSIDE (FLAP OPEN)

30mm X 4mm SCREW

30mm X 4mm SCREW

30mm X 4mm SCREW

30mm X 4mm SCREW

FRONT VIEW - STS 4001 OUTSIDE (FLAP OPEN)

30mm X 4mm SCREW

30mm X 4mm SCREW

30mm X 4mm SCREW

30mm X 4mm SCREW

TOP VIEW - INSIDE SLEEVE (FLAP CLOSED)

INNER SLEEVE

MASTIC TO THIS SURFACE

MASTIC TO THIS SURFACE

MASTIC TO THIS SURFACE

MAIN FIXING SCREW MAIN FIXING SCREW

[email protected]+44 (0)1661 830101 +44 (0)1661 897454 www.sealedtightsolutions.comUnits 1b - 1d, Princess Court, Prudhoe, Northumberland. NE42 6NP.

30mm X 2mm INTUMESCENT LINER

30mm X 2mm INTUMESCENT LINER