U NI V ER SA L -X R THE ONE AND ONLY CONTROLLER THAT SHOULD BE ON YOUR TRUCK Replaces most Models of Refrigeration & Heating Controllers Heating Medium Temp. Low Temp. Defrost Fan Quick installation. Replaces dozens of Controls in the Field. Select 120V, 230V or 12/24V Controllers. Fast configuration in 3 simple steps. 7 pre-programmed applications. 1 2 3 R E D U C E t h a t i o n T I M E ! (After connecting Wiring/Probes) and applying power. Press the DOWN key for 3 seconds to automatically detect and set the probe type (PTC or NTC) Press the AUX key for 3 seconds to select your type of application tC1 – tC7 Hold the SET key to adjust the SET-POINT Up / Down Auto Probe Detection The default is NTC (Black) sensors, if there are PTC (White) sensors you can Auto-detect the probes. Heating, Medium Temp., Low Temp. and Advanced. 29 mm x 71mm Panel IP65 from Front NTC/PTC Probe Inputs LOAD 1: SPST 16FLA/96LRA, 16 A RES LOAD 2: 10A (SPDT) LOAD 3: 5A (SPST) DIGITAL INPUT: 1 Door Switch RANGE: -40/230 °F (NTC) -40/302 °F (PTC) AMBIENT: 32/140 °F UL and NSF Listing Includes - 2 NTC Probes - 5 FT. (Can be extended to 300 FT) The continuous improvement of Dixell’s products can result in some variations in the information included in this bulletin even without notice. c2 1 3 4 5 • XR60CX-4N1F1-UR -120VAC • XR60CX-5N1F1-UR -230VAC • XR60CX-AN1F1-UR-12/24VAC XR110C XR10C XR10CX XR01CX XR130C XR30C XR30CX XR03CX XR140C XR40C XR40CX XR04CX XR160C XR60C XR60CX XR06CX XR50CX XR62CX XR64CX XR120C XR20C XR20CX XR20CE XR02CX HEATING WARMING 1 PROBE MEDIUM TEMP. OFF CYCLE D EFROST TIME / TIME 1 PROBE MEDIUM TEMP. OFF CYCLE DEFROST TIME / TEMP 2 PROBES MEDIUM TEMP. W / ALARM OFF CYCLE D EFROST TIME / TEMP 2 PROBES MED/LOW TEMP. W / ALARM ELECTRIC OR HOT GAS D EFROST TIME / TEMP 2 PROBES LOW TEMP. ELECTRIC OR HOT GAS D EFROST TIME / TEMP FAN CONTROL 2 PROBES HEAT / COOL 2 COM PRESSORS 2 D EFROSTS LIGHTS ALARMS 2 - 4 PROBES ADVANCED CONTROL APPLICATIONS Part No’s. Fast SET-UP in 3 Simple Steps Specifications: 7 Pre-Configured Applications UNIV-XR replaces the majority of Controls for:

UNIVERSAL-XR - Weiss Instruments

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

UNIVERSAL-XR THE ONE AND ONLY CONTROLLER THAT SHOULD BE ON YOUR TRUCK

Replaces most Models of Refrigeration & Heating Controllers

Heating Medium Temp. Low Temp. Defrost Fan

Quick installation. Replaces dozens of Controls in the Field.

Select 120V, 230V or 12/24V Controllers.

Fast confi guration in 3 simple steps. 7 pre-programmed applications.

1

2

3

RED

UCE th llation TIM

E!

(After connecting Wiring/Probes) and applying power.

Press the DOWN key for 3 seconds to automatically detect and set the probe type (PTC or NTC)

Press the AUX keyfor 3 seconds to select your type of applicationtC1 – tC7

Hold the SET keyto adjust the SET-POINTUp / Down

Auto Probe DetectionThe default is NTC (Black) sensors, if there are PTC (White) sensors you can Auto-detect the probes.

Heating, Medium Temp., Low Temp. and Advanced.

• 29 mm x 71mm Panel

• IP65 from Front

• NTC/PTC Probe Inputs• LOAD 1: SPST 16FLA/96LRA, 16 A RES

• LOAD 2: 10A (SPDT)

• LOAD 3: 5A (SPST)

• DIGITAL INPUT: 1 Door Switch

• RANGE: -40/230 °F (NTC) -40/302 °F (PTC)• AMBIENT: 32/140 °F• UL and NSF Listing• Includes - 2 NTC Probes - 5 FT.

(Can be extended to 300 FT)

The continuous improvement of Dixell’s products can result in some variationsin the information included in this bulletin even without notice.

c2

1

3

4

5

• XR60CX-4N1F1-UR -120VAC• XR60CX-5N1F1-UR -230VAC• XR60CX-AN1F1-UR-12/24VAC

XR110CXR10CXR10CXXR01CX

XR130CXR30CXR30CXXR03CX

XR140CXR40CXR40CXXR04CX

XR160CXR60CXR60CXXR06CX

XR50CXXR62CXXR64CX

XR120CXR20CXR20CX

XR20CEXR02CX

HEATINGWARMING

1 PROBE

MEDIUM TEMP.OFF CYCLE DEFROSTTIME / TIME 1 PROBE

MEDIUM TEMP.OFF CYCLE DEFROSTTIME / TEMP

2 PROBES

MEDIUM TEMP.W / ALARMOFF CYCLE DEFROSTTIME / TEMP

2 PROBES

MED/LOW TEMP.W / ALARMELECTRIC OR HOTGAS DEFROSTTIME / TEMP

2 PROBES

LOW TEMP.ELECTRIC OR HOTGAS DEFROSTTIME / TEMPFAN CONTROL 2 PROBES

• HEAT / COOL• 2 COM PRESSORS• 2 DEFROSTS• LIGHTS• ALARMS• 2 - 4 PROBES

ADVANCED CONTROL

APPLICATIONSPart No’s.

Fast SET-UPin 3 Simple Steps

Specifications:

7 Pre-Configured Applications

UNIV-XR replaces the majority of Controls for: