PC5950

Universal VOX Audio Verification Module

Installation Manual

WARNING: This document contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. Read the entire manually carefully.

FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by Digi-tal Security Controls Ltd. could void your authority to use this equip-ment.This equipment has been tested and found to comply with the limits fora Class B digital device, pursuant to Part 15 of the FCC Rules. Theselimits are designed to provide reasonable protection against harmfulinterference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and, if not installed andused in accordance with the instructions, may cause harmful interfer-ence to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipmentdoes cause harmful interference to radio or television reception, whichcan be determined by turning the equipment off and on, the user isencouraged to try to correct the interference by one or more of the fol-lowing measures:

Re-orient the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from

that to which the receiver is connected.Consult the dealer or an experienced radio/television technician for

help.The user may find the following booklet prepared by the FCC useful:"How to Identify and Resolve Radio/Television Interference Prob-lems". This booklet is available from the U.S. Government PrintingOffice, Washington D.C. 20402, Stock # 004-000-00345-4.IMPORTANT INFORMATIONThis equipment complies with Part 68 of the FCC Rules and therequirements adopted by the ACTA. On the side of this equipment is alabel that contains, among other information, a product identifier in theformat US:AAAEQ##TXXXX. If requested, this number must be pro-vided to the Telephone Company.Product identifier: US:F53KX01BPC5950USOC Jack: RJ-31XTelephone Connection Requirements A plug and jack used to connect this equipment to the premises wiringand telephone network must comply with the applicable FCC Part 68rules and requirements adopted by the ACTA. A compliant telephonecord and modular plug is provided with this product. It is designed tobe connected to a compatible modular jack that is also compliant. Seeinstallation instructions for details.Ringer Equivalence Number (REN)The REN is used to determine the number of devices that may be con-nected to a telephone line. Excessive RENs on a telephone line mayresult in the devices not ringing in response to an incoming call. Inmost but not all areas, the sum of RENs should not exceed five (5.0).To be certain of the number of devices that may be connected to a line,as determined by the total RENs, contact the local Telephone Com-pany. For products approved after July 23, 2001, the REN for thisproduct is part of the product identifier that has the format US: AAAEQ##TXXXX. The digits represented by ## are the RENwithout a decimal point (e.g., 03 is a REN of 0.3). For earlier products,the REN is separately shown on the label.

Incidence of HarmIf this equipment PC5950 causes harm to the telephone network, thetelephone company will notify you in advance that temporary discon-tinuance of service may be required. But if advance notice is not practi-cal, the Telephone Company will notify the customer as soon aspossible. Also, you will be advised of your right to file a complaintwith the FCC if you believe it is necessary.Changes in Telephone Company Equipment or FacilitiesThe Telephone Company may make changes in its facilities, equip-ment, operations or procedures that could affect the operation of theequipment. If this happens the Telephone Company will provideadvance notice in order for you to make necessary modifications tomaintain uninterrupted service.Equipment Maintenance FacilityIf trouble is experienced with this equipment PC59500, for repair orwarranty information, please contact the facility indicated below. If theequipment is causing harm to the telephone network, the TelephoneCompany may request that you disconnect the equipment until theproblem is solved. This equipment is of a type that is not intended to berepaired by the end user.DSC c/o APL Logistics, 757 Douglas Hill Rd., Lithia Springs, GA- 30122 USA Additional InformationConnection to party line service is subject to state tariffs. Contact thestate public utility commission, public service commission or corpora-tion commission for information.Alarm dialing equipment must be able to seize the telephone line andplace a call in an emergency situation. It must be able to do this even ifother equipment (telephone, answering system, computer modem, etc.)already has the telephone line in use. To do so, alarm dialing equip-ment must be connected to a properly installed RJ-31X jack that iselectrically in series with and ahead of all other equipment attached tothe same telephone line. Proper installation is depicted in the figurebelow. If you have any questions concerning these instructions, youshould consult your telephone company or a qualified installer aboutinstalling the RJ-31X jack and alarm dialing equipment for you.

Telephone

Computer

Telephone

Telephone

Fax Machine

Alarm DialingEquipment

RJ-31XJack

UnusedRJ-11 Jack

TelephoneLine

NetworkService

Provider'sFacilities

Customer Premises Equipment and Wiring

UnusedRJ-11 Jack

NetworkDemarcation

PointAnswering

System

IC: 160A -PC5950NOTICE: This equipment meets the applicable Industry CanadaTerminal Equipment Technical Specifications. This is confirmedby the registration number. The abbreviation, IC, before theregistration number signifies that registration was performedbased on a Declaration of Conformity indicating that IndustryCanada technical specifications were met. It does not implythat Industry Canada approved the equipment.

NOTICE: The Ringer Equivalence Number (REN) for this termi-nal equipment is 0.1. The REN assigned to each terminalequipment provides an indication of the maximum number ofterminals allowed to be connected to a telephone interface.The termination on an interface may consist of any combina-tion of devices subject only to the requirement that the sumof the Ringer Equivalence Numbers of all the devices does notexceed 5.

AVIS: Le présent matériel est conforme aux spécifications tech-niques d’Industrie Canada applicables au matériel terminal.Cette conformité est confirmée par le numéro d'enregistre-ment. Le sigle IC, placé devant le numéro d'enregistrement, sig-nifie que l’enregistrement s’est effectué conformément à unedéclaration de conformité et indique que les spécifications tech-niques d'Industrie Canada ont été respectées. Il n’implique pasqu’Industrie Canada a approuvé le matériel.

AVIS : L'indice d'équivalence de la sonnerie (IES) du présentmatériel est de 0.1. L'IES assigné à chaque dispositif terminalindique le nombre maximal de terminaux qui peuvent être rac-cordés à une interface téléphonique. La terminaison d'uneinterface peut consister en une combinaison quelconque dedispositifs, à la seule condition que la somme d'indices d'équiv-alence de la sonnerie de tous les dispositifs n'excède pas 5.

Table of Contents

Sect Description Page

11.11.2

Introduction ................................................................................................. 1Specifications.................................................................................................. 1Out-of-the-Box ............................................................................................... 2

22.12.2

Installation ................................................................................................... 3PC5950 Installation......................................................................................... 3Audio Station Wiring ...................................................................................... 3

33.13.23.33.3.13.3.23.4

Operation ..................................................................................................... 6Configurations................................................................................................ 6KEYBUS Configuration.................................................................................... 6Universal Configuration .................................................................................. 6Auto-sense Mode ........................................................................................... 6Triggered Mode .............................................................................................. 6Audio Control Telephone Key Functions........................................................ 7

44.14.24.3

Programming ............................................................................................... 8Programming - Keybus Mode.......................................................................... 8Programming - Universal Mode..................................................................... 13Programming - User...................................................................................... 14

1

1 IntroductionThe PC5950 series Universal VOX Audio Verification Modules provide "Talk / Listen-in" capability for audio verification of alarms. The module permits the central station to monitor microphones and commu-nicate to the occupants through speakers. The central station can control volume etc. with telephone key presses in accordance with SIA Audio Verification protocol.

The user can also remotely initiate audio monitoring of the premises.

The PC5950 series modules connects directly to PowerSeries control panels via the KEYBUS. Third party alarm panels can be connected using the Bell output and a programmable output (PGM). A Telco connection is provided for telephone line connections (required for Audio Verification). The PC5950 Talk/Listen-in options are selectable by the central station operator using telephone keys (1-9) and (*). See “Audio Control Telephone Key Functions” on page 7.

The module mounts in the main control panel cabinet (PC5003C) using existing mounting holes (see Fig-ure 3, Installation). In Keybus Mode, all programming can be performed at the system keypad or remotely using DLS software (DSC Panels only), In Universal mode the unit is programmed via key presses from a remote telephone.

1.1 Specifications

Figure 1: PC5950 Audio Verification Module

Operating Temperature range:.........................................................32°-122°F (0°-50°C)

Humidity..................................................................................0-to-93% non-condensing

Operating voltage (RED, BLK)...................................................... 11.0 - 13.8 VDC (max)

Current Draw (Board Only) .......................................................................... 54mA (max)

Current Draw (Max) ................................................................................... 150mA (max)

AUX Output:............................................................................................ 11.5 - 12.5 VDC

PC5904 .................................................................................... 175 mA (max)PC5921 ...................................................................................... 50 mA (max)PC5961, PC5962 ....................................................................... 60 mA (max)PC5964 .................................................................................... 200 mA (max)

Wiring Distance (All Audio Stations)............................................................500ft (152m)

Audio Range:PC5961, PC5962 ...........................................................................25ft.(7.6m)PC5964 .......................................................................................50ft. (15.2m)

Compatible Control Panels ...... PC5010, PC5020, PC1864, PC1832, PC1808, PC1616

Associated Modules:PC5921 .........................................Audio Station with Page and DND buttonsPC5904 ............................................................................2-way Audio stationPC5961 ........................................................................... 2-way Audio StationPC5962 ..........................................................Contoured 2-way Audio StationPC5964 ........................................................................... 2-way Audio Station

UA538

2

1.2 Out of the Box: The PC5950 Kit includes the following:

Figure 2: Installation

• 1 PC5950 Audio Verification Module• 4 Standoffs

• 1 Installation Manual• 1 User Guide

UA538

Standoff

Cabinet

PC Board

MountingHoles

Not used

Not used

Insert 4Standoffs

Here

CautionDo NOT route wiring over the PC5950 moduleMaintain at least 1”, (25.4 mm) separationMinimum 1/4” (6.44 mm) must be maintained at all pointsbetween power limited and non power limited wiring

3

2 Installation2.1 PC5950 InstallationThe PC5950 module must be installed by SERVICE PERSONNEL ONLY. It must be installed in ametallic cabinet properly grounded. It is the installer’s responsibility to ensure such degree ofprotection for the equipment that NO ACCESS to the TNV circuit is given to the end user. Themetallic cabinet must be secured to the building structure before operation. A proper groundconnection must be provided for the metal cabinet. Internal wiring must be routed in a man-ner that prevents:

• excessive strain on wire and on terminal connections• loosening of terminal connections• damage to conductor insulation

Follow these steps to install the PC5950 audio interface module and audio stations. Reviewthis section to get an overall understanding of the order of installation. Once this is done, care-fully work through each step.

1. Insert the 4 standoffs provided in the position indicated in figure 3. The standoffs will make an audible “click” when positioned correctly.

2. Position the module over the standoffs and press firmly to ensure that the module locks in place.

3. Wire module to the Control Panel, microphones, speakers or Escort as required. Refer to figure 4.

4. Program Module as required (see Section 3 Programming).5. Verify operation.

2.2 Audio Station WiringUp to 4 audio stations (4 microphones and 2 speakers) can be connected to the PC5950 audiointerface module. Each Audio Station must be home-run to the interface module via 22gauge, 4-conductor cable. Each Audio Station can be up to 500ft (152m) from the PC5950.

Connect each station to the audio connections on the PC5950 module as indicated in figure 3.

Figure 2 Terminal Connections.

Note:

Do NOT use shielded wire on KEYBUS wire runs. The distributed capacitance of shielded wire can significantly reduce signal quality and range. Wire all other connections with 22AWG shielded wire

UA538

4

Figure 2: Wiring Details‘

Pow

erS

erie

sC

ontr

ol P

ane

lTo

out

side

ph

one

line

To h

ouse

phon

e lin

e

Esc

ort

(Opt

iona

l)

*Uni

vers

alC

ontr

ol P

anel

PC

5950

PC

5950

A P

ow

erS

erie

s W

irin

g D

iag

ram

B U

niv

ersa

l Co

nfi

gu

rati

on

Wir

ing

Dia

gra

m

To o

utsi

de

phon

e lin

e

To B

ell

To h

ouse

phon

e lin

e

*Not

e:

Con

nect

ions

may

var

yde

pend

ing

on c

onfig

urat

ion

Bel

l inp

ut is

5

Figure 3, PC5950 Terminal Connections

Keybus REDBLKYEL

GRN

KEYBUS Power (Aux+ from Universal Panel)KEYBUS Ground (Com from Universal Panel) KEYBUS Clock Input (Trigger Mode: TRG- Kissoff, Auto-sense Mode: Enable input from 3rd party PGM)KEYBUS Data Input / Output (Enable input from 3rd party PGM)

Bell Bell +

Bell -

OFF

Bell (Bell input from Universal Panel Bell

Note: If the Bell Output from the alarm panel is negative it can be connected directly to the PC5950 Bell+ Terminal. Positive triggered outputs require a relay to shunt the Bell+ terminal to the COM terminal.

Bell (Bell Output)

For Future Use

Aux Power AUX

COM

Auxiliary Power Output AUX (PTC protected locally).

Note: Output current is limited by the available current at panel the AUX/ RED output (refer to the control panel Installation Manual)

Common Ground

Tamper TMP Speaker Tamper (Triggered by zone activation from Universal Panel)

Speaker/Mic M1M2M3M4

Microphone #1 Input ChannelMicrophone #2 Input ChannelMicrophone #3 Input ChannelMicrophone #4 Input Channel

Speakers SPK1SPK2

Speaker Level Output (supports two DSC Audio Stations)Speaker Level Output (supports two DSC Audio Stations)

Note: SPK1 and SPK2 are parallel wired from a single audio output. Any combination of Audio Stations can be used as long as maximum the current draw is not exceeded: - 4 Small Stations (PC5961/62) - 2 Large Stations (PC5964) - 1 Large & 2 small Stations

Phone Line RNGTIPR-1T-1

TELCO Ring connection from panelTELCO Tip connection from panelTELCO Ring connection to in-house phonesTELCO Tip connection to in-house phone

Ground EGND Earth Ground

UA538

6

3 Operation3.1 Configurations

The PC5950 operates in two different configurations KEYBUS and UNIVERSAL. The KEYBUS configu-ration is intended for use with DSC Alarm Panels that have a KEYBUS. this configuration provides addi-tional features (see figure 3a). The Universal Configuration is intended for use with third party Alarm systems (see figure 3b). PC5950 searches for a KEYBUS on startup. If a KEYBUS is not found within 20 seconds, the system automatically configures itself in the UNIVERSAL configuration.

3.2 KEYBUS ConfigurationThis wiring configuration applies to DSC Panels only. The PC5950 connects directly to the PowerSeries panel keybus in this wiring configuration. The module can be directly programmed from the system Key-pad by entering [*][8][Installer Code][802] followed by the associated section numbers in Section 3 of this manual.

3.3 Universal Configuration

This wiring configuration applies to alarm systems that do not support Audio Verification or do not have a KEYBUS. The UNIVERSAL configuration can operate in the Auto-sense Mode or in the Trigger Mode

3.3.1 Auto-sense Mode:

In this mode the PC5950 is activated by an output from the alarm panel that indicates that an event has been transmitted that requires a 2-way audio session (e.g., System Event). The module senses when the the panel has finished communicating and then seizes the line and initiates a 2-way audio session based on the criteria listed in the table below.

3.3.2 Trigger Mode:

In this mode the PC5950 is activated by an output from the alarm panel that indicates that an event has been transmitted that requires that a 2-way Audio session to be initiated immediately (e.g., Kissoff). The module immediately seizes the line and initiates a 2-way audio session based on the criteria listed in the table below.

Table 2.1, Auto-sense Mode & Trigger Mode Criteria

EnableRequiredOption

Trig/PGM Enable/BellAuto/Sense

Mode Triggered

Mode

ON Inactive Inactive None None

ON Active Inactive None None

ON Inactive Active Talk/Listen None

ON Active Active Talk/Listen Talk/Listen

OFF Inactive Inactive None None

OFF Active Inactive Listen Listen

OFF Inactive Active Talk/Listen Talk/Listen

OFF Active Active Talk/Listen Talk/Listen

7

3.4 Audio Control Telephone Key Functions

The PC5950 functions are controlled using [*] key during a telephone session as per the SIA Audio Veri-fication Standard. Enter [*] followed by [0] or [1] to select the level followed by the 1 or 2-digit key number of the desired action. Alarm and Talk/Listen options can occur from any partition on the system.

Note:

When an audio verification session has been initiated, the module is in “line hold mode” and waits for the operator to press a touch tone digit.

Note:

Use Disconnect key [99] or [88] to terminate a session before hanging up.

Entering [*][0] followed by [0] - [99] selects the following options:

[0] Future Use

[1] High Gain Talk-to-allConnects the Central Monitoring Station to all Speakers at Hi volume level

[2] Two-way VOXConnects the Central Monitoring Station to all Speakers and all active microphones. An internal voice switch automatically switches between “Listen” and “Talk” modes

[3] Hi-gain Listen to all active MicrophonesConnects the Central Monitoring Station to all active microphones at Hi gain level

[4] Lo-gain Talk-to-allConnects the Central Monitoring Station to all Speakers at Lo volume level

[5] Future Use

[6] Lo-gain Listen to all active MicrophonesConnects the Central Monitoring Station to all active microphones at Lo gain level

[7] Extend TimeRestarts the session timer to prevent time-out.

[88] Disconnect with Call-back WindowDisconnects the session then starts the Call-back Window (if programmed) to allow the Central Monitoring Station to resume the session later.Note: The second “8” must be pressed within 1 second of pressing the first “8”

[99] DisconnectTerminates the session.Note: The second “9” must be pressed within 1 second of pressing the first “9”

Entering [*][1] followed by [0] - [9] selects the following options:

[0]-[1] Future Use

[2] Microphone SelectEnter 0 - 5 to toggle (enable or disable depending on the previous state) the associated microphone. This allows the Central Station Operator to deselect undesirable microphone inputs. Selecting 0 turns all inputs OFF. Selecting 5 turns all inputs ON. Selecting 1 - 4 tog-gles the corresponding microphone.

[3] Zone Select 01 - 64 (Keybus mode only)Enter a 2-digit zone number (01-64) after entering this key to activate a microphone input associated with the zone for a listen-in session. If the selected zone does NOT have micro-phone input, the function is cancelled and the module reverts to the previous state.

[4] Increment Selected MicrophoneSelects the next enabled microphone in the sequence.

[5] Decrement Selected MicrophoneSelects the previous enabled microphone in the sequence.

[6]-[9] Future Use

8

4. Programming4.1 Programming - KEYBUS ModeNOTE: If Programming The PC5950 via DLS (Keybus configuration), select PC5936 for the correct pro-gramming options

Enter [�][8][Installer Code][802] on the system keypad followed by the desired subsection (listed below) to program options.

NOTE: Numbering of this section corresponds with the numbering of the Programming Worksheets.

[04] Call Back/Recovery Window DurationValid Entries 01-09 minutes, 00 to disable

[05] Call Back Acknowledge CodeValid Entries are 0000-9999

[06] Answering Machine BypassNumber of Rings (Valid Entries 01-09, 00 to disable)

NOTE: Program this section with a value greater than 2 for DLS Double-call support.[07] Answering Machine Bypass Double-call Timer

Number of Rings (Valid Entries 00-99 seconds)

[08] Number of Rings to Answer OnNumber of Rings (Valid Entries 01-09, 00 to disable)

[10] Audio OptionsThe Alarm and Talk / Listen option (option 2) will occur for events from all zones and partitions. If option 2 is not selected the Talk/Listen option will only be initiated for zones in alarm.

[12] Audio DurationThis section allows programming of the length of time that the Audio Module will remain on-line with the receiver in Talk / Listen-In. The on-line time can be manually extended by the operator. Valid entries are 00-99 seconds, the default is 90 seconds.

[14] Audio Station Tamper OptionsEnables or disables audio tampers for 4 speakers/microphones. Default is disabled

[30]-[37] Audio Control OptionsThese sections enable / disable specific Zone Alarms that will initiate an audio verification session.

[38] Ninth Audio Control Options (Listen-In Options)These options enable/disable system events that cause the panel to initiate Talk / Listen-In upon com-pletion of the communication handshake. The following system events can be programmed to initiate Talk/ Listen-In.

Tampers NOpenings/Closing N[A] Alarm N[P] Alarm NDuress Alarm NZone Exp. Sup. Alarm NOpen After Alarm N

NOTE: The Alarm and Talk / Listen-in options will occur for events from any partition (entire system).

9

[40]-[47] Microphone Input Assignments (Microphone Inputs)Each zone on the system can be assigned to the nearest Microphone Input for Central Station Talk/Lis-ten. Enter 01-04 for each zone on the system to assign it to the nearest microphone input available.

NOTE: If Section [10] Option 2 is enabled all microphones will be active.

[998] Factory Default ProgrammingWhen this section is successfully entered on the PowerSeries panel, all programming in the PC5950 Audio Verification Module will be returned to the factory defaults. Enter [998][Installer Code][998] at the system keypad. Hardware Default: A hardware default can be performed if the installer code is lost by powering up the system with the GRN terminal shorted to the Bell In terminal.

PC5950 v1.0 Programming Worksheets - KEYBUS Mode

[04] Call Back Recovery Window Duration

Valid entries are 01-09 minutes, 00 to disable I___I___I Default 05

[05] Call Back Acknowledge Code

Valid entries are 0000-9999 I___I___I___I___I Default 9999

[06] Answering Machine Bypass

# of Rings (Valid entries are 01-09, 00 to disable) I___I___I Default 00

NOTE: Program this section with a value greater than 2 for DLS Double-call support

[07] Answering Machine Bypass Double-call Timer

Valid entries are 01-99 seconds I___I___I Default 30

[08] Number of Rings to Answer On

# of Rings (Valid entries are 01-09, 00 to disable) I___I___I Default 00

[10] Audio Options (� Denotes Option Default)

Opt Option ON Option OFF

1 � Future Use ��

2 �� Listen to all zones when on-line � Listen to zones in alarm only

3 � Bell Follower Enabled �� Bell Follower Disabled

4 � Tamper Output Active Hi �� Tamper Output Active Lo

5 �� Hang-up Auto-detect Enabled � Hang-up Auto-detect Disabled

6 � User Call-in Enabled �� User Call-in Disabled

[12] Audio Duration

Valid entries are 01-99 seconds I___I___I Default 90

[14] Audio Station Tamper Options

Opt Option ON Option OFF

1 � Audio Station #1 tamper Enabled �� Disabled

2 � Audio Station #2 tamper Enabled �� Disabled

3 � Audio Station #3 tamper Enabled �� Disabled

4 � Audio Station #4 tamper Enabled �� Disabled

5-8 � Future Use ��

10

[30] 1st Audio Control Options (� Denotes Option Default)

Opt Option ON Option OFF

1 � Zone 1 Alarm Enabled �� Disabled

2 � Zone 2 Alarm Enabled �� Disabled

3 � Zone 3 Alarm Enabled �� Disabled

4 � Zone 4 Alarm Enabled �� Disabled

5 � Zone 5 Alarm Enabled �� Disabled

6 � Zone 6 Alarm Enabled �� Disabled

7 � Zone 7 Alarm Enabled �� Disabled

8 � Zone 8 Alarm Enabled �� Disabled

[31] 2nd Audio Control Options (� Denotes Option Default)

Opt Option ON Option OFF

1 � Zone 9 Alarm Enabled �� Disabled

2 � Zone 10 Alarm Enabled �� Disabled

3 � Zone 11 Alarm Enabled �� Disabled

4 � Zone 12 Alarm Enabled �� Disabled

5 � Zone 13 Alarm Enabled �� Disabled

6 � Zone 14 Alarm Enabled �� Disabled

7 � Zone 15 Alarm Enabled �� Disabled

8 � Zone 16 Alarm Enabled �� Disabled

[32] 3rd Audio Control Options (� Denotes Option Default)

Opt Option ON Option OFF

1 � Zone 17 Alarm Enabled �� Disabled

2 � Zone 18 Alarm Enabled �� Disabled

3 � Zone 19 Alarm Enabled �� Disabled

4 � Zone 20 Alarm Enabled �� Disabled

5 � Zone 21 Alarm Enabled �� Disabled

6 � Zone 22Alarm Enabled �� Disabled

7 � Zone 23 Alarm Enabled �� Disabled

8 � Zone 24 Alarm Enabled �� Disabled

[33] 4th Audio Control Options (� Denotes Option Default)

Opt Option ON Option OFF

1 � Zone 25 Alarm Enabled �� Disabled

2 � Zone 26 Alarm Enabled �� Disabled

3 � Zone 27 Alarm Enabled �� Disabled

4 � Zone 28 Alarm Enabled �� Disabled

5 � Zone 29 Alarm Enabled �� Disabled

6 � Zone 30 Alarm Enabled �� Disabled

7 � Zone 31 Alarm Enabled �� Disabled

8 � Zone 32 Alarm Enabled �� Disabled

11

[34] 5th Audio Control Options (� Denotes Option Default)

Opt Option ON Option OFF

1 � Zone 33 Alarm Enabled �� Disabled

2 � Zone 34 Alarm Enabled �� Disabled

3 � Zone 35 Alarm Enabled �� Disabled

4 � Zone 36 Alarm Enabled �� Disabled

5 � Zone 37 Alarm Enabled �� Disabled

6 � Zone 38 Alarm Enabled �� Disabled

7 � Zone 39 Alarm Enabled �� Disabled

8 � Zone 40 Alarm Enabled �� Disabled

[35] 6th Audio Control Options (� Denotes Option Default)

Opt Option ON Option OFF

1 � Zone 41 Alarm Enabled �� Disabled

2 � Zone 42 Alarm Enabled �� Disabled

3 � Zone 43 Alarm Enabled �� Disabled

4 � Zone 44 Alarm Enabled �� Disabled

5 � Zone 45 Alarm Enabled �� Disabled

6 � Zone 46 Alarm Enabled �� Disabled

7 � Zone 47 Alarm Enabled �� Disabled

8 � Zone 48 Alarm Enabled �� Disabled

[36] 7th Audio Control Options (� Denotes Option Default)

Opt Option ON Option OFF

1 � Zone 49 Alarm Enabled �� Disabled

2 � Zone 50 Alarm Enabled �� Disabled

3 � Zone 51 Alarm Enabled �� Disabled

4 � Zone 52 Alarm Enabled �� Disabled

5 � Zone 53 Alarm Enabled �� Disabled

6 � Zone 54 Alarm Enabled �� Disabled

7 � Zone 55 Alarm Enabled �� Disabled

8 � Zone 56 Alarm Enabled �� Disabled

[37] 8th Audio Control Options (� Denotes Option Default)

Opt Option ON Option OFF

1 � Zone 57 Alarm Enabled �� Disabled

2 � Zone 58 Alarm Enabled �� Disabled

3 � Zone 59 Alarm Enabled �� Disabled

4 � Zone 60 Alarm Enabled �� Disabled

5 � Zone 61 Alarm Enabled �� Disabled

6 � Zone 62 Alarm Enabled �� Disabled

7 � Zone 63 Alarm Enabled �� Disabled

8 � Zone 64 Alarm Enabled �� Disabled

[38] 9th Audio Control Options (� Denotes Option Default)

Opt Option ON Option OFF

1 � Tampers Enabled �� Disabled

2 � Openings & Closings Enabled �� Disabled

12

3 � A Key Alarm Enabled �� Disabled

4 � P Key Alarm Enabled �� Disabled

5 � Duress Alarm Enabled �� Disabled

6 � Zone Expander Superv Alarm �� Disabled

7 � Opening After Alarm Enabled �� Disabled

8 � Future Use �� Disabled

[40] Microphone Input Assignments, Zones 1-8

(Enter nearest microphone input number (01-04, 00=Not Used) Default

Zone 1 Microphone Input Assignment I___I___I 00

Zone 2 Microphone Input Assignment I___I___I 00

Zone 3 Microphone Input Assignment I___I___I 00

Zone 4 Microphone Input Assignment I___I___I 00

Zone 5 Microphone Input Assignment I___I___I 00

Zone 6 Microphone Input Assignment I___I___I 00

Zone 7 Microphone Input Assignment I___I___I 00

Zone 8 Microphone Input Assignment I___I___I 00

[41] Microphone Input Assignments, Zones 9-16

(Enter nearest microphone input number (01-04, 00=Not Used) Default

Zone 9 Microphone Input Assignment I___I___I 00

Zone 10 Microphone Input Assignment I___I___I 00

Zone 11 Microphone Input Assignment I___I___I 00

Zone 12 Microphone Input Assignment I___I___I 00

Zone 13 Microphone Input Assignment I___I___I 00

Zone 14 Microphone Input Assignment I___I___I 00

Zone 15 Microphone Input Assignment I___I___I 00

Zone 16 Microphone Input Assignment I___I___I 00

[42] Microphone Input Assignments, Zones 17-24

(Enter nearest microphone input number (01-04, 00=Not Used) Default

Zone 17 Microphone Input Assignment I___I___I 00

Zone 18 Microphone Input Assignment I___I___I 00

Zone 19 Microphone Input Assignment I___I___I 00

Zone 20 Microphone Input Assignment I___I___I 00

Zone 21 Microphone Input Assignment I___I___I 00

Zone 22 Microphone Input Assignment I___I___I 00

Zone 23 Microphone Input Assignment I___I___I 00

Zone 24 Microphone Input Assignment I___I___I 00

[43] Microphone Input Assignments, Zones 25-32

(Enter nearest microphone input number (01-04, 00=Not Used) Default

Zone 25 Microphone Input Assignment I___I___I 00

Zone 26 Microphone Input Assignment I___I___I 00

Zone 27 Microphone Input Assignment I___I___I 00

Zone 28 Microphone Input Assignment I___I___I 00

Zone 29 Microphone Input Assignment I___I___I 00

Zone 30 Microphone Input Assignment I___I___I 00

Zone 31 Microphone Input Assignment I___I___I 00

Zone 32 Microphone Input Assignment I___I___I 00

13

[44] Microphone Input Assignments, Zones 33-40

(Enter nearest microphone input number (01-04, 00=Not Used) Default

Zone 33 Microphone Input Assignment I___I___I 00

Zone 34 Microphone Input Assignment I___I___I 00

Zone 35 Microphone Input Assignment I___I___I 00

Zone 36 Microphone Input Assignment I___I___I 00

Zone 37 Microphone Input Assignment I___I___I 00

Zone 38 Microphone Input Assignment I___I___I 00

Zone 39 Microphone Input Assignment I___I___I 00

Zone 40 Microphone Input Assignment I___I___I 00

[45] Microphone Input Assignments, Zones 41-48

(Enter nearest microphone input number (01-04, 00=Not Used) Default

Zone 41 Microphone Input Assignment I___I___I 00

Zone 42 Microphone Input Assignment I___I___I 00

Zone 43 Microphone Input Assignment I___I___I 00

Zone 44 Microphone Input Assignment I___I___I 00

Zone 45 Microphone Input Assignment I___I___I 00

Zone 46 Microphone Input Assignment I___I___I 00

Zone 47 Microphone Input Assignment I___I___I 00

Zone 48 Microphone Input Assignment I___I___I 00

[46] Microphone Input Assignments, Zones 49-56

(Enter nearest microphone input number (01-04, 00=Not Used) Default

Zone 49 Microphone Input Assignment I___I___I 00

Zone 50 Microphone Input Assignment I___I___I 00

Zone 51 Microphone Input Assignment I___I___I 00

Zone 52 Microphone Input Assignment I___I___I 00

Zone 53 Microphone Input Assignment I___I___I 00

Zone 54 Microphone Input Assignment I___I___I 00

Zone 55 Microphone Input Assignment I___I___I 00

Zone 56 Microphone Input Assignment I___I___I 00

[47] Microphone Input Assignments, Zones 57-64

(Enter nearest microphone input number (01-04, 00=Not Used) Default

Zone 57 Microphone Input Assignment I___I___I 00

Zone 58 Microphone Input Assignment I___I___I 00

Zone 59 Microphone Input Assignment I___I___I 00

Zone 60 Microphone Input Assignment I___I___I 00

Zone 61 Microphone Input Assignment I___I___I 00

Zone 62 Microphone Input Assignment I___I___I 00

Zone 63 Microphone Input Assignment I___I___I 00

Zone 64 Microphone Input Assignment I___I___I 00

[998] Factory Default Programming

[998][Installer Code][998] Restores all programming to the defaults indi-cated above

14

4.2 Programming - Universal ModeProgramming of the PC5950 in Universal mode is performed using the telephone. The Installer can access programming by entering the Installer Code (Default 5555) when the module answers a call.

After correctly entering the Installer Code the module will sound 3 high pitched beeps. An incorrect entry will result in a 1 long low pitched beep. Enter the 2-digit code of the corresponding option indicated in the table below.

Programming Options - Universal Mode

Option Description

� Indicates the default setting

011

� 2

Hard-wire/Auto-trip Hard Trip: Use this setting if the control panel provides a kissoff (2-way activation)Auto-trip: Use this setting if the control panel does NOT provides a kissoff

02� 1

2

Activate immediately/1-Ring Call Back modeTrigger Input (hard-wired or auto-trip), module seizes phone line immediately Trigger Input (hard-wired or auto-trip), module enables 1-ring call back

Note: To enable first time programming the unit is defaulted to full time call back(number of rings) to one ring (Option 16). Disable this feature during programming if not required.

Central Monitoring Station (CMS) Modes

Notes: The user can call-in when the CMS or CMS window is not active.The CMS call-in window is activated after an alarm.The CMS call-in recovery window is activated when a CMS session is terminated abnormally (i.e., not ended by the CMS by pressing the end key (99) or time-out (forgot to Extend).The two call-in windows use the same programmable timer.

03 � 90 Audio Session DurationSelects the number of seconds (01-99) the listen-in session lastsThe Extend Time function resets to this value

04 � 5 Call-back Recovery Window DurationSelects the number of minutes (1-9) the recovery window remains open(See Option 2)0 = disabled

05 � 9999 Call-back Acknowledge Code4-digit programmable code (0000-9999) that allows access in Call-back modeDSC recommends that this code is different from the User and Installer codes

06� 1

2

Hang-up Auto-detectSystem Hangs up if disconnected.System remains on-line until time-out

071

� 2

Trigger Input Active LevelTrigger enabled when trigger input HI (open)Trigger enabled when trigger input Lo (switched to ground)

SettingWindow

(See Opt 4)Activity

1 0 Activate CMS Immediately, No CMS call-in window, no CMS call-in recovery window

2 1-9 Does Not activate CMS immediately, No CMS call-in win-dow, no CMS call-in recovery window (no CMS mode)

1 0 Activate CMS immediately, no CMS-call-in window, CMS call-in recovery window (typical method)

2 1-9 Does Not activate CMS immediately, CMS call-in window after alarm, CMS call-in recovery window.

15

4.3 User Code ProgrammingUser code programming is accessed during by entering [*][5] during a User Call-in sessionRefer to the Audio Verification Feature Guide for details

081

� 2

Enable Input Active LevelTrigger enabled when Enable input HI (open)Trigger enabled when Enable input Lo (switched to ground)

09� 1

2

Bell Input Active LevelTrigger enabled when Bell input HI (open)Trigger enabled when Bell input Lo (switched to ground)

10� 1

2

Trigger Enable RequiredAuto-trip: enable required. Hard Trip: trigger enabled by Bell AND GRNAuto-trip: enable NOT required. Hard Trip: trigger enabled by Bell OR GRN

14 � 0 Answering Machine BypassSelects the number of rings (1-9) required on first call for hang up and callback.Unit always answers on first ring of second call 0 = disabled

15 � 30 Answering Machine Bypass Double-call TimerSelects the maximum delay (01-99 seconds) between calls on double-call (from last ring of first call).

16 � 1 Full-time Call-back Number of RingsSelects the number of rings (1-9) to receive before answering User or InstallerCMS Call-back and Recovery always answer on first ring.

Note: If Option 14 and option 16 are set to 0, module will answer on first ring

0 = Disabled

17� 1

2

User Call-inAllows User code to initiate an audio session from a call-in.Does NOT allow User code to initiate an audio session from a call-in.

20 � 5555 Installer Code4-digit programmable code (0000-9999) that allows access by Installer or Central Station.DSC recommends that this code is different from the User and Call-back acknowledge codes. If set to the same value as the User Code, only User access will be granted.

211

� 2

Audio Station 1 Tamper OptionAudio Station 1 tamper enabled.Audio Station 1 tamper disabled.

221

� 2

Audio Station 2 Tamper OptionAudio Station 2 tamper enabled.Audio Station 2 tamper disabled.

231

� 2

Audio Station 3 Tamper OptionAudio Station 3 tamper enabled.Audio Station 3 tamper disabled.

241

� 2

Audio Station 4 Tamper OptionAudio Station 4 tamper enabled.Audio Station 4 tamper disabled.

251

� 2

Tamper Out Terminal Active LevelTamper on any microphone will switch TMP terminal from GND to Open.Tamper on any microphone will switch TMP terminal from Open to GND.

261

� 2

Bell FollowerSpeaker sounds alarm in the cadence detected on the Bell Input.Speaker does NOT sound alarm.

99 [Installer Code][99]Entering [99][Installer Code][99] will reset the unit to factory default programming.

Limited WarrantyDSC warrants that for a period of one year from the date of purchase, the product shall be free of defects in material and workmanship under normal use and that in fulfillment of any breach of such warranty, DSC shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot. This warranty applies only to defects in materials and workmanship and not to damage incurred in shipping or handling, or damage due to causes beyond the control of DSC, such as lightning, excessive voltage, mechanical shock, water damage or damage arising out of abuse, alteration or improper application of the product.

The foregoing warranty shall apply only to the original buyer, and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of DSC. This warranty contains the entire warranty. DSC neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf, to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product.

In no event shall DSC be liable for any direct, indirect or consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation or failure of this product.

IMPORTANT!DSC recommends that the entire system be completely tested on a regular basis. However, despite frequent testing, and due to but not limited to criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected.

©2007 Digital Security Controls.Toronto, Canada • www.dsc.comTechnical Support: 1-800-387-3630 (Canada & U.S.) or 905-760-3036 29007315R002