26
UNBONDED PRE- STRESSED CONNECTIONS Prof. John F. Stanton University of Washington, Seattle, Washington, USA The ROSE School, Pavia. June 2009

Unbonded PreStress Connections

  • Upload
    vungoc

  • View
    233

  • Download
    4

Embed Size (px)

Citation preview

Page 1: Unbonded PreStress Connections

UNBONDED PRE-STRESSED

CONNECTIONSProf. John F. Stanton

University of Washington,Seattle, Washington, USA

The ROSE School, Pavia.June 2009

Page 2: Unbonded PreStress Connections

REFERENCE DOCUMENT

Design Guidelines for Precast Concrete Seismic Structural

Systems

John F. Stanton & Suzanne D. NakakiPRESSS Report No. 01/03-09

Available from PCI (and on Rose School website)

Page 3: Unbonded PreStress Connections

UNBONDED PRESTRESSED CONCRETE FRAME:

GOALS• Zero residual drift (ZRD)

– Frame returns to vertical after earthquake

• Damped response

– Damping restricts peak drift

• Little damage even in a large earthquake

– Building can be re-occupied quickly

Page 4: Unbonded PreStress Connections

POSSIBLE CONFIGURATIONS:(Continuous beams)

Page 5: Unbonded PreStress Connections

POSSIBLE CONFIGURATIONS:(Continuous columns)

Page 6: Unbonded PreStress Connections

CONFIGURATIONS

• Continuous Columns– Often used by precasters

• Continuous Beams– Long Heavy Beams– Columns must be accurately placed for bars to fit

Page 7: Unbonded PreStress Connections

REINFORCEMENT CONFIGURATIONS

• Unbonded prestressing only– Simple to construct, but no hysteretic damping.– Damping could be supplied by external devices or

RC frames in parallel with UBPT frame.

• UB prestressing + rebar = “Hybrid Frame”– Internal hysteresis (damping) supplied by rebar– All-in-one package.

Page 8: Unbonded PreStress Connections

UBPT Prestressed-only Frame

Shown with post-tensioned beams, multi-storey columns.Requires post-tensioning on site. Easy fit-up.

Post‐tensioning tendon 

(unbonded) Post‐tensioning  anchorage

Page 9: Unbonded PreStress Connections

UBPT Prestressed-only Frame

Pre‐stressing tendon

Bonded region

Unbonded region

Shown with pretensioned beams, one-storey columns.Can prestress in plant. Columns must be accurately placed.

Page 10: Unbonded PreStress Connections

UBPT Prestressed-only Frame Components

Unbonded PT tendon

Grout

Page 11: Unbonded PreStress Connections

Hybrid Frame Components

Unbonded PT tendon

Bonded Rebar

Rebar locally debonded

Grout

Page 12: Unbonded PreStress Connections

Deformed Shape

Page 13: Unbonded PreStress Connections

Deformed Shape

Page 14: Unbonded PreStress Connections

Deformed Shape

Page 15: Unbonded PreStress Connections

Deformed Shape

Page 16: Unbonded PreStress Connections

Hybrid Frame Components(Courtesy Nakaki Bashaw Group)

Pre-tensioned strands

Beam rebar (not continuous)

Sleeves for column bars (grouted)

Grout bed at interface

Column bar splices

Only the pre-tensioned strands cross the interface

Page 17: Unbonded PreStress Connections

Hybrid Frame Components(Courtesy Nakaki Bashaw Group)

Mild steel (A706) (grouted)

Unbonded region

Post Tensioned Tendon (ungrouted)

Fiber Reinforced Grout

Page 18: Unbonded PreStress Connections

UBPT FRAME CONCEPT

• PT tendon provides strength

• PT provides elastic restoring force

• Damping is minimal (use 5% critical)

Page 19: Unbonded PreStress Connections

NON-LINEAR ELASTIC BEHAVIORLINEAR NONLINEAR

ELASTIC

INELASTIC

σ σ

σ

ε

εε

Elastic: Load and unload along the same pathInelastic: Load and unload along different pathsLinear: Load/unload path is a straight lineNonlinear: Load/unload paths are not straight.

Page 20: Unbonded PreStress Connections

Hybrid Frame combines both features

Force - Deflection

•Returns to vertical•Nonlinear elastic•Low damping

•Residual drift•Nonlinear inelastic•High damping

PT only

Rebar only

Page 21: Unbonded PreStress Connections

Hysteresis Loops - Combinations

100/0

25/75 0/100

50/5075/25

Page 22: Unbonded PreStress Connections

DESIGN PROCEDURE

• Rational design procedure

• Design forces same as cast-in-place concrete SMRF

• Explicit evaluation of drift capacity

• Design of other parts of frame: per code

Page 23: Unbonded PreStress Connections

ASSUMPTIONS

• All deformation occurs at the interface, not in the beam.

• PT is unbonded the entire length of the frame, except for bonded region at each end.

• cgp is at mid beam-height.

Page 24: Unbonded PreStress Connections

LIMIT STATESWe need to define limit states at which the moment

strength will be computed.

• Nominal moment strength:• Corresponds to the design moment. • Used to size the reinforcement at the interface

• Maximum probable strength• Corresponds to the Maximum Credible

earthquake• Forms the basis for Capacity Design forces for

adjacent elements.

Page 25: Unbonded PreStress Connections

NOMINAL STRENGTH LIMIT STATE

Smaller of • Onset of strain hardening in mild steel (if any).• Yield of PT steel.

Comparable to nominal strength of reinforced concrete frame

Page 26: Unbonded PreStress Connections

MAXIMUM PROBABLE STRENGTH LIMIT STATE

• Smaller of : • Strain at peak strength of mild steel.• Yield of PT steel.

System must have at least 3.5% drift capacity at MPS limit state.