MICROMASTER 410/420/430/440 Inverters 0.12 kW to 250 kW Catalog DA 51.2 2002 micromaster

Umschlag DA 51 2 engl0/2 Siemens DA 51.2 · 2002 MICROMASTER 410/420/430/440 0 Overview Guidelines Main areas of application “The low-priced” for variable speeds with three-phase

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

  • MICROMASTER 410/420/430/440Inverters0.12 kW to 250 kW

    Ca

    talo

    g D

    A 5

    1.2

    • 2

    00

    2

    micromaster

  • MICROMASTER 410/420/430/440 Inverters

    Order No.:German: E86060-K5151-A121-A3English: E86060-K5151-A121-A3-7600

    DA 51.2

    COMBIMASTER 411/MICROMASTER 411 DA 51.3(in preparation)Order No.:German: E86060-K5151-A131-A1 English: E86060-K5151-A131-A1-7600

    MICROMASTER, MICROMASTER VectorMIDIMASTER Vector, COMBIMASTERYou can download the catalog in the Internet under the following address:http://www.siemens.com/micromaster

    DA 64

    Wechsel- und DrehstromstellerSIVOLT A/V(available only in German)Order No.:German: E20002-K4068-A101-A1

    DA 68

    Semiconductor-Protection Fuses SITOR

    Order No.:German: E20002-K4094-A111-A3English: E20002-K4094-A111-A2-7600

    DA 94.1

    Low-Voltage Motors

    Order No.:German: E86060-K1711-A101-A1English: E86060-K1711-A101-A1-7600

    M 11

    Getriebemotoren 2KG1(available only in German)

    Order No.:German: E86060-K1715-A101-A2

    M 15

    Automation & Drives

    Order No.: German: E86060-D4001-A100-B7English: E86060-D4001-A110-B7-7600

    CA 01

    Trademarks / Internet

    ® COMBIMASTER, MICROMASTER, MIDIMASTER, SIMOVIS, SITOR and SIVOLT are Siemens registered trademarks.All other products and system names in this catalog are (registered) trademarks of their respective owners and must be treated accordingly.

    Visit the Automation & Drives Group in the Internet under the following address:http://www.siemens.com/automation

    Catalogs of the Business Unit “Standard Drives”

  • MICROMASTER 410/420/430/440Inverters0.12 kW to 250 kW

    Catalog DA 51.2 × 2002Supersedes: Catalog DA 51.2 × 2001

    s

    © Siemens AG 2002

    Overview

    MICROMASTER 410

    0.12 kW to 0.75 kW

    MICROMASTER 420

    0.12 kW to 11 kW

    MICROMASTER 430

    7.5 kW to 90 kW

    1

    0

    2

    3

    4

    A

    MICROMASTER 440

    0.12 kW to 250 kW

    Appendix

    The products and systems referred to in this catalog are marketed with a DQS certified management system.The DQS certificate is recog-nized in all IQ Net countries.

    DQS certified according toDIN EN ISO 9001 Reg. No. 357-05DIN EN ISO 14001 Reg. No. 81342-01

    BSI certified according toBS EN ISO 9001 Reg. No. FM 25845

    Management system

  • Siemens DA 51.2 · 20020/2

    MICROMASTER 410/420/430/440

    0

    Overview

    ■Guidelines

    Main areas of application “The low-priced”for variable speeds with three-phase motors on single-phase networks,e.g. with pumps, fans, billboards, cabinets,gate drives and automatic machines

    “The universal”for three-phase networks and optional fieldbus interfacing,e.g. for conveyor belts, material transport,pumps, fans and machine tools

    Power ranges 0.12 kW to 0.75 kW 0.12 kW to 11 kW

    Voltage ranges 100 V to 120 V 1 AC 200 V to 240 V 1 AC

    200 V to 240 V 1 AC 200 V to 240 V 3 AC 380 V to 480 V 3 AC

    Control • V/f characteristic• Multipoint characteristic

    (programmable V/f characteristic)• FCC (flux current control)

    • V/f characteristic• Multipoint characteristic

    (programmable V/f characteristic)• FCC (flux current control)

    Process control – Internal PI controller

    Inputs 3 digital inputs1 analog Input

    3 digital inputs1 analog input

    Outputs 1 relay output 1 analog output1 relay output

    Interfacing to automation system

    The PLC partner for LOGO! andSIMATIC S7-200

    The ideal partner for your automation tasks, whether with SIMATIC S7-200, SIMATIC S7-300/400 (TIA) or SIMOTION

    Additional features • Natural ventilation (no fan unit)• Position of connections as with

    conventional switching elements (e.g. contactors)

    • BICO technology

    MICROMASTER 410MICROMASTER 410 MICROMASTER 420MICROMASTER 420

    Section 1Section 1 Section 2Section 2

  • Siemens DA 51.2 · 2002 0/3

    0“The specialist for pumps and fans”with optimized OP (manual/automatic switchover),matched software functionality and optimized power efficiency

    “The all-purpose”with advanced vector control (with and without encoder feedback)for versatile applications in sectors such as conveying systems,textiles, elevators, hoisting gear and machine construction

    7.5 kW to 90 kW 0.12 kW to 250 kW

    380 V to 480 V 3 AC 200 V to 240 V 1 AC 200 V to 240 V 3 AC 380 V to 480 V 3 AC 500 V to 600 V 3 AC

    • V/f characteristic• Multipoint characteristic

    (programmable V/f characteristic)• FCC (flux current control)

    • V/f characteristic• Multipoint characteristic

    (programmable V/f characteristic)• FCC (flux current control)• Vector control

    Internal PID controller Internal PID controller(autotuning)

    6 digital inputs2 analog inputs1 PTC/KTY input

    6 digital inputs2 analog inputs1 PTC/KTY input

    2 analog outputs3 relay outputs

    2 analog outputs3 relay outputs

    The ideal partner for your automation tasks, whether with SIMATIC S7-200, SIMATIC S7-300/400 (TIA) or SIMOTION

    The ideal partner for your automation tasks, whether with SIMATIC S7-200, SIMATIC S7-300/400 (TIA) or SIMOTION

    • Low-energy mode• Load torque monitoring

    (detects running dry of pumps)• Motor staging

    • 3 selectable drive data sets• Integrated brake chopper (up to 75 kW)• Torque control

    MICROMASTER 430MICROMASTER 430 MICROMASTER 440MICROMASTER 440

    Section 3Section 3 Section 4Section 4

    Overview

    MICROMASTER 410/420/430/440

  • Siemens DA 51.2 · 20020/4

    MICROMASTER 410/420/430/440

    0

    ■Options

    Operator panels

    Modules

    Various options are available for the MICROMASTER:■ Filters■ Chokes■ Operator panels■ PROFIBUS module■ DeviceNet module■ Pulse encoder evaluation

    module■ Gland plates■ Mounting kits, etc.

    Assignment of operator panels and modules to the converter ranges

    Accessories Order No. MICROMASTER410 420 430 440

    Operator panelsOP 6SE6400-0SP00-0AA0 %BOP 6SE6400-0BP00-0AA0 % %AOP 6SE6400-0AP00-0AA0 % %

    6SE6400-0AP00-0AA1 % %BOP-2 6SE6400-0BE00-0AA0 %

    ModulesPROFIBUS 6SE6400-1PB00-0AA0 % % %DeviceNet 6SE6400-1DN00-0AA0 % % %Pulse encoder evaluation 6SE6400-0EN00-0AA0 %

    % Possible combination

    BOP/OP AOP BOP-2

    PROFIBUS DeviceNet Pulse encoder evaluation

    Overview

  • Siemens DA 51.2 · 2002 1/1

    1

    InverterMICROMASTER 410

    1/2 Description

    1/4 Circuit Diagrams

    1/6 Technical Data

    1/7 Selection and Ordering Data

    1/8 Options

    1/10 Dimension Drawings

  • Siemens DA 51.2 · 20021/2

    MICROMASTER 410

    1

    ■ApplicationsThe MICROMASTER 410 inverter is suitable for a variety of variable-speed drive appli-cations.

    It is especially suitable for use with pumps and fans, as a drive in various sectors, e.g. food, textile and packaging industries, as well as for conveyor systems, factory gate and garage door drives, and as a universal drive for moving billboards.

    It is the ideal low-cost fre-quency inverter solution for the bottom performance range of the MICROMASTER family.

    The inverter is especially characterized by its customer-oriented performance and ease of use.

    Versions for connection to 230-V and 115-V single-phase networks enable it to be used all over the world.

    ■DesignThe MICROMASTER 410 has a compact design.

    Heat sinks provide natural cooling for the inverter. A fan unit is not used.

    The position of the connec-tions has been selected as for conventional contactors.

    The operator panel available as an option can be easily fitted without requiring any tools.

    ■Main Characteristics■ Simple selection from

    minimum range of types (only few options)

    ■ Compact design■ Natural cooling with heat

    sinks (no fan unit)■ Simple connection similar

    to conventional switching elements (e.g. contactors)

    ■ Version with internal EMC filter Class B

    ■ Fast, simple commission-ing with input of only a few parameters (fast commis-sioning mode)

    ■ Integral RS-485 communi-cations interface

    ■ Three programmable digital inputs, non-floating (the analog input can be used as a 4th digital input)

    ■ One analog input (0 V to 10 V)

    ■ One programmable relay output (30 V DC/5 A resistive; 250 V AC/2 A inductive)

    ■ Low-noise motor operation resulting from high pulse frequency

    ■ Integral protection for motor and inverter.

    ■Options (Overview)■ Line commutating chokes■ Adapter for standardized

    mounting on DIN rails■ OP operator panel for

    parameterizing an inverter■ PC connection set■ PC commissioning tool.

    ■ International Standards■ The MICROMASTER 410

    inverter complies with the requirements of the EU low-voltage guideline; filtered versions also comply with the EU EMC guideline

    ■ The MICROMASTER 410 inverter has the > marking

    ■ u and cu listed■ c-tick ●✔

    Note:

    See Appendix for standards.

    Frame size AA Frame size AB

    Description

  • Siemens DA 51.2 · 2002 1/3

    MICROMASTER 410

    1

    ■Mechanical Features ■Performance Features ■Protection Features■ Compact design ■ Heat dissipation through

    self-ventilation (convection)■ Operating temperature

    -10 °C to +50 °C■ Easy cable connection,

    mains and motor connec-tions are separated for optimum electromagnetic compatibility and clear connection

    ■ Detachable, optional operator panels

    ■ Screwless control terminals■ Side mounting possible,

    thus also usable with low cabinet depth.

    ■ Latest IGBT technology■ Digital microprocessor

    control■ Linear V/f characteristic,

    with programmable voltage boosting

    ■ Quadratic V/f characteristic■ Multipoint characteristic

    (programmable V/f charac-teristic)

    ■ Flying restart■ Automatic restart facility

    following power failure or fault

    ■ Programmable accelera-tion (0 s to 650 s) with ramp smoothing

    ■ Fast current limit (FCL) for trip free operation

    ■ Fast, repeatable digital input response time

    ■ Fine speed adjustment using a high resolution 10-bit analog input

    ■ One skip frequency■ Removable “Y” capacitor

    for use on IT mains supplies■ Serial RS-485 interface with

    USS protocol■ LED for status information■ Versions with internal EMC

    filter Class B.

    ■ Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s, then 0.85 x rated output current for 240 s, cycle time 300 s

    ■ Overvoltage/undervoltage protection

    ■ Inverter overtemperature protection

    ■ Earth fault protection■ Short circuit protection■ I2t motor thermal protection■ Stall prevention.

    Description

  • Siemens DA 51.2 · 20021/4

    MICROMASTER 410

    1

    ■General Circuit Diagram

    DA51-5034b

    7

    4

    5

    24 V

    DIN4

    +

    -

    A

    Voltage supply(external orinternal source)

    For an additional digital input (DIN 4) externalconnections should be made:

    1

    2

    3

    4

    5

    6

    7

    8

    24 V

    DIN1

    DIN2

    DIN3

    AIN+

    RL1-B

    RL1-C

    P+

    N-

    11

    12

    9

    RL1

    +10 V

    P

    I Fn

    O

    M3~

    DA51-5033b

    A

    D

    CPU

    PE

    PE

    FS1

    PE

    U, V, W

    10

    DC+

    DC-

    Jog

    +

    -

    +

    -

    Serialinter-faceRS-485

    Voltage supply(external orinternal source)

    Output relay contacts250 V AC, max. 2 A(inductive load)30 V DC, max. 5 A(resistive load)

    0 V

    L, N

    4.7 k->

    100 V to 120 V 1 AC 200 V to 240 V 1 AC

    max. 33 Vmax. 5 mA

    +24 V (max. 50 mA)

    AC

    DC

    DC

    AC

    A

    Voltage supply and analog input

    Input voltage: 0 V to + 10 V,scalable

    Operator panel (Option)

    Circuit Diagrams

  • Siemens DA 51.2 · 2002 1/5

    MICROMASTER 410

    1

    ■Terminal Connection Diagram

    1 3 42 5 6 8 97

    11 12

    RL1-B RL1-C

    0V

    10

    DA

    51

    -50

    35a

    +10V AIN+

    RS-485

    DIN2 DIN3 +24V 0V P+ DIN1 N-

    RL1

    (USS protocol)

    Output relay

    Voltagesupply 10 V

    Analog input

    Output relay contacts

    Digital inputs Voltagesupply 24 V

    A

    View A

    View A

    Motor connections

    Mains connections

    Circuit Diagrams

  • Siemens DA 51.2 · 20021/6

    MICROMASTER 410

    1

    ■MICROMASTER 410 inverter

    ■Derating DataPulse frequency

    The current data apply to an ambient temperature of 50 °C unless specified otherwise.

    Input voltage and power ranges

    200 V to 240 V 1 AC ± 10 %100 V to 120 V 1 AC ± 10 %

    0.12 to 0.75 kW0.12 to 0.55 kW

    Input frequency 47 to 63 HzOutput frequency 0 Hz to 650 HzPower factor ³ 0.95Inverter efficiency 96 % to 97 %Overload capability Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s;

    then 0.85 x rated output current for 240 s, cycle time 300 sInrush current less than rated input currentControl method linear V/f; quadratic V/f; multipoint characteristic (programmable V/f)PWM frequency 8 kHz (standard)

    2 kHz to 16 kHz (in 2 kHz steps)Fixed frequencies 3, programmableSkip frequency bands 1, programmableSetpoint resolution 10 bit analog

    0.01 Hz serialDigital inputs 3 programmable digital inputs, non-floating; PNP, SIMATIC-compatibleAnalog inputs 1, for setpoint (0 V to 10 V, scaleable or for use as 4th digital input)Relay outputs 1, configurable 30 V DC/5 A (resistive), 250 V AC/2 A (inductive)Serial interfaces RS-485, for operation with USS protocolMotor cable length max. 30 m (shielded)

    max. 50 m (unshielded)Electromagnetic compatibility Inverter available with internal EMC filter to EN 61 800-3

    (defined limits to EN 55 011, Class B)Braking DC Braking, Compound BrakingProtection level IP 20Temperature range –10 °C to +50 °CStorage temperature –40 °C to +70 °CHumidity 95 % (non-condensing) Operational altitudes up to 1000 m above sea level without deratingProtection features for • under-voltage

    • over-voltage• overload• earth faults • short circuits• stall prevention • I2t motor thermal protection• motor over-temperature

    Conformity with standards u, cu, >, c-tick ●✔> marking Conformity with EC low voltage directive 73/23/EC

    filtered versions also with electromagnetic compatibility directive 89/336/ECDimensions and weights (without options)

    Frame size (FS)AAAB

    H x W x D (mm)150 x 69 x 118150 x 69 x 138

    Weight, approx. (kg)0.81.0

    Rated output Rated output current in Afor a pulse frequency of

    kW 4 kHz 6 kHz 8 kHz 10 kHz 12 kHz 14 kHz 16 kHz0.12 0.9 0.9 0.9 0.8 0.7 0.6 0.50.25 1.7 1.7 1.7 1.5 1.3 1.1 0.90.37 2.3 2.3 2.3 2.0 1.7 1.5 1.30.55 3.2 3.2 3.2 2.9 2.6 2.3 2.00.55, 115 V (at 50 °C) 3.0 3.0 2.7 2.5 2.2 2.0 1.70.55, 115 V (at 40 °C) 3.2 3.2 3.2 2.9 2.6 2.3 2.00.75 (at 50 °C) 3.9 3.9 3.6 3.2 2.9 2.6 2.30.75 (at 40 °C) 4.2 4.2 4.2 3.8 3.4 3.0 2.7

    Technical Data

  • Siemens DA 51.2 · 2002 1/7

    MICROMASTER 410

    1

    ■Derating Data (continued)Installation height above sea level

    ■MICROMASTER 410 Inverter

    The current data apply to an ambient temperature of 50 °C unless specified otherwise.

    Rated output

    Rated input current 1)

    Rated outputcurrent

    Frame size Order No.

    kW hp A A (FS)MICROMASTER 410 without filter

    MICROMASTER 410 with internal filter Class B

    Mains operating voltage 100 V to 120 V 1 AC, output voltage 200 V to 240 V 3 AC0.12 0.16 4.6 0.9 AA 6SE6410-2UA11-2AA0 –0.25 0.33 7.5 1.7 AA 6SE6410-2UA12-5AA0 –0.37 0.50 10.1 2.3 AA 6SE6410-2UA13-7AA0 –0.55 0.75 13.4 2.7 (3.2 at 40 °C) AB 6SE6410-2UA15-5BA0 –

    Mains operating voltage 200 V to 240 V 1 AC, output voltage 200 V to 240 V 3 AC0.12 0.16 1.5 0.9 AA 6SE6410-2UB11-2AA0 6SE6410-2BB11-2AA00.25 0.33 3.0 1.7 AA 6SE6410-2UB12-5AA0 6SE6410-2BB12-5AA00.37 0.50 4.4 2.3 AA 6SE6410-2UB13-7AA0 6SE6410-2BB13-7AA00.55 0.75 5.8 3.2 AB 6SE6410-2UB15-5BA0 6SE6410-2BB15-5BA00.75 1.0 7.8 3.6 (4.2 at 40 °C) AB 6SE6410-2UB17-5BA0 6SE6410-2BB17-5BA0

    See Appendix for note on ordering.

    All MICROMASTER 410 inverters are supplied without an operator panel (OP). An OP or other options have to be ordered additionally (see page 1/9).

    ■Motors for MICROMASTER 410

    Catalog M 11 contains selec-tion and ordering data for motors which are particularly suitable for operation with the MICROMASTER 410 inverters (see Appendix for overview).

    2000

    60

    0 40000

    20

    40

    80

    DA51-5038a

    100

    1000

    %

    3000 m

    75

    Main

    s vo

    ltage

    Operational altitude

    A

    2000

    60

    0 40000

    20

    40

    80

    DA51-5039a

    100

    1000

    %

    3000 m

    90

    A

    Ra

    ted

    out

    pu

    t cu

    rren

    t

    Operational altitude

    Permissible output current in % of the rated output current

    Permissible mains voltagein % of the max. possible mains voltage

    Selection and Ordering Data

    1) The values apply to rated mains voltages of 115 V or 230 V.

    Technical Data

  • Siemens DA 51.2 · 20021/8

    MICROMASTER 410

    1

    ■Variant Dependent OptionsEMC filter, Class B

    Variants with internal EMC filter Class B are available for inverters with a mains operat-ing voltage of 230 V 1 AC.

    • The requirements are ful-filled using shielded cables with a max. length of 5 m, or 10 m with a low-capaci-tance motor cable (core/core < 75 pF/m, core/shield < 150 pF/m).The limits comply with EN 55 011 Class B.

    An inverter with internal filter can be used with a 30-mA residual current operated cir-cuit-breaker, and is only suit-able for hardwired installation.

    A non-filtered inverter together with the optional filter “Filter Class B with low leakage cur-rents” has a leakage current £ 3.5 mA (shielded motor cable up to 5 m).

    Line commutating choke

    Line commutating chokes are used to smooth voltage peaks or to bridge commutating dips.

    In addition, line commutating chokes reduce the effects of harmonics on the inverter and the power supply.

    If the ratio of inverter rated power to netwerk short-circuit power is less than 1 %, a line commutating choke must be used in order to reduce the current peaks.

    The line commutating chokes are designed as footprint chokes and are fitted between the inverter and the mounting plate.

    In line with the EN 61 000-3-2 regulations “Limits for har-monic currents with device input current £ 16 A per phase”, there are special aspects for drives with 250 W to 550 W and 230-V single-phase supplies which can be used in non-industrial applica-tions (1st environment).

    For devices with 250 W and 370 W it is necessary either to fit the recommended input chokes or to apply to the power utility company for authorization to connect the devices to the public power supply. No limits are currently defined in the EN 61 000-3-2 standard for professionally used devices with a connected load > 1 kW. This means that the inverters with an output power ³ 0.75 kW comply with the EN 61 000-3-2 standard.

    ■Variant Independent OptionsOperator Panel (OP)

    With the OP, individual param-eter settings can be made.

    Values and units are shown on a 5-digit display.

    An OP can be used for several inverters. It is directly plugged into the inverter.

    Connection set forPC to inverter

    For controlling and commis-sioning an inverter directly from a PC if the appropriate software has been installed (e.g. STARTER).

    The connection set includes an RS-485/RS-232 interface converter with a 9-pin Sub-D connector.

    Commissioning tools

    • STARTER Starter is graphic start-up software for guided commis-sioning for MICROMASTER 410/420/430/440 frequency inverters under Windows NT/2000. Parameter lists can be read out, altered, stored, entered and printed.

    • DriveMonitorDriveMonitor is start-up software for list-oriented programming of frequency inverters under Windows 95/98/NT/2000.

    Inverter with Operator Panel (OP)

    Options

  • Siemens DA 51.2 · 2002 1/9

    MICROMASTER 410

    1

    *) With these inverters, the choke cannot be mounted in the substructure; it must be mounted upright.

    ■Documentation

    ■Ordering Data for Variant Dependent OptionsThe options listed here (filters, chokes, fuses and circuit breakers) are inverter specific.

    The inverter and the associ-ated options have the same voltage ratings.

    All variant dependent options and the operator panel are certified to u, except fuses. The fuses of type 3NA3 are recom-mended for Europe.

    Use in America requires u-listed fuses such as e.g. the Class NON range from Bussmann.

    Mains operating voltage

    Rated output

    Inverter without filter

    Order No. of the options

    kW

    Filter Class B with low leakage currents

    Line commutatingchoke

    Fuse(see Catalog NS K)

    Circuit-breaker(see Catalog NS K)

    100 V to 120 V 1 AC

    0.12 6SE6410-2UA11-2AA0 – 6SE6400-3CC01-0AB0 3NA3803 3RV1021-1GA10

    0.25 6SE6410-2UA12-5AA0 – 3RV1021-1JA10

    0.37 6SE6410-2UA13-7AA0 *) – 6SE6400-3CC02-6BB0 3NA3805 3RV1021-1KA10

    0.55 6SE6410-2UA15-5BA0 *) – 3NA3807 3RV1021-4AA10

    200 V to 240 V 1 AC

    0.12 6SE6410-2UB11-2AA0 6SE6400-2FL01-0AB0 6SE6400-3CC00-4AB0 3NA3803 3RV1021-1BA10

    0.25 6SE6410-2UB12-5AA0 3RV1021-1EA10

    0.37 6SE6410-2UB13-7AA0 6SE6400-3CC01-0AB0 3RV1021-1FA10

    0.55 6SE6410-2UB15-5BA0 3RV1021-1HA10

    0.75 6SE6410-2UB17-5BA0 3NA3805 3RV1021-1JA10

    Inverter with internal filter Class B

    200 V to 240 V 1 AC

    0.12 6SE6410-2BB11-2AA0 – 6SE6400-3CC00-4AB0 3NA3803 3RV1021-1BA10

    0.25 6SE6410-2BB12-5AA0 – 3RV1021-1EA10

    0.37 6SE6410-2BB13-7AA0 – 6SE6400-3CC01-0AB0 3RV1021-1FA10

    0.55 6SE6410-2BB15-5BA0 – 3RV1021-1HA10

    0.75 6SE6410-2BB17-5BA0 – 3NA3805 3RV1021-1JA10

    ■Ordering Data for Variant Independent OptionsThe options listed here are suitable for all MICROMASTER 410 Inverters.

    Options Order No.Operator Panel (OP) 6SE6400-0SP00-0AA0Connection set for PC to inverter 6SE6400-0PL00-0AA0Adapter for mounting on DIN rail 6SE6400-0DR00-0AA0Start-up tools STARTER and DriveMonitor, as well as multilanguage documentation on CD-ROM

    6SE6400-5EA00-1AG0

    Type of documentation Language Order No.Operating instructions 1)(paper version)

    German 6SE6400-5EA00-0AP0English 6SE6400-5EA00-0BP0French 6SE6400-5EA00-0DP0Italian 6SE6400-5EA00-0CP0Spanish 6SE6400-5EA00-0EP0

    Parameter list 1) (paper version)

    German 6SE6400-5EB00-0AP0English 6SE6400-5EB00-0BP0French 6SE6400-5EB00-0DP0Italian 6SE6400-5EB00-0CP0Spanish 6SE6400-5EB00-0EP0

    Getting Started Guide 1) (paper version), included with every inverter

    Multilanguage –

    1) Available on Internet at http://www.siemens.com/micromaster.

    Options

  • Siemens DA 51.2 · 20021/10

    MICROMASTER 410

    1

    ■MICROMASTER 410 Inverter

    ■Line commutating chokes

    Inverter frame size AA6SE6410-2 . . 11-2AA06SE6410-2 . . 12-5AA06SE6410-2 . . 13-7AA0

    Inverter frame size AB6SE6410-2 . . 15-5BA06SE6410-2 . . 17-5BA0

    69(2.72)

    118

    (4.65

    )

    150

    (5.9

    )12

    (0.4

    7)16

    0 (6

    .30)

    DA

    51-5

    036a

    A

    Ø 4.5(0.18)

    DA

    51-5

    037a

    69(2.72)

    138

    (5.43

    )

    Ø 4.5(0.18) 1

    2(0

    .47)

    160

    (6.3

    0)

    150

    (5.9

    )

    A

    All dimensions in mm (values in brackets are in inches)

    Footprint chokes6SE6400-3CC00-4AB06SE6400-3CC01-0AB0

    Chokes for upright mounting6SE6400-3CC02-6BB0

    DA

    51-5

    040b

    A

    73 (2.87)

    200

    (7.8

    7)

    50(1.97)

    149(5.87)

    213

    (8.3

    9)

    70(2.76)

    AD

    A51

    -504

    1b

    All dimensions in mm (values in brackets are in inches)

    Dimension Drawings

  • Siemens DA 51.2 · 2002 2/1

    2

    InverterMICROMASTER 420

    2/2 Description

    2/4 Circuit Diagrams

    2/6 Technical Data

    2/8 Selection and Ordering Data

    2/9 Options

    2/16 Dimension Drawings

  • Siemens DA 51.2 · 20022/2

    MICROMASTER 420

    2■Applications ■Main Characteristics ■Options (Overview) ■ International Standards

    The MICROMASTER 420 inverter is suitable for a variety of variable-speed drive applications. It is especially suitable for applications for pumps, fans and conveyor systems.

    It is especially characterized by its customer-oriented performance and ease of use. Its large supply-voltage range enables it to be used all over the world.

    ■DesignThe MICROMASTER 420 has a modular design. The opera-tor panels and communica-tions modules can be easily exchanged without requiring any tools.

    ■ Simple commissioning■ Modular construction

    allows maximum configura-tion flexibility

    ■ Three fully programmable isolated digital inputs

    ■ One scalable analog input (0 V to 10 V) can also be used as a 4th digital input

    ■ One programmable analog output (0 mA to 20 mA)

    ■ One fully programmable relay output(30 V DC/5 A, resistive250 V AC/2 A, inductive)

    ■ Silent motor operation is selectable when using high switching frequencies, adjustable (observe derat-ing if necessary)

    ■ Complete inverter and motor protection.

    ■ EMC filters Class A/B■ Line commutating chokes■ Output chokes■ Gland plates ■ BOP basic operator panel

    for parameterizing an inverter

    ■ AOP advanced operator panel with plain-text and multilingual display

    ■ Communications modules– PROFIBUS– DeviceNet

    ■ PC connection kits■ Assembly kits for mounting

    the operator panels in the control cabinet doors

    ■ PC commissioning tools, running under Windows 95/98 and NT/2000.

    ■ The MICROMASTER 420 inverter complies with the requirements of the EU low-voltage guideline; filtered versions also comply with the EU EMC guideline

    ■ The MICROMASTER 420 inverter has the > marking

    ■ u and cu listed■ c-tick ●✔

    Note:

    See Appendix for standards.

    Description

  • Siemens DA 51.2 · 2002 2/3

    MICROMASTER 420

    2

    ■Mechanical Features ■Performance Features ■Protection Features■ Modular design■ Operating temperature:

    –10 °C to +50 °C■ Compact housing as a

    result of high power density■ Easy cable connection,

    mains and motor connec-tions are separated for optimum electromagnetic compatibility

    ■ Detachable operator panels

    ■ Screwless control termi-nals.

    ■ Latest IGBT technology■ Digital microprocessor

    control■ Flux current control (FCC)

    for improved dynamic response and optimized motor control

    ■ Linear V/f characteristic■ Quadratic V/f characteristic■ Multipoint characteristic

    (programmable V/f charac-teristic)

    ■ Flying restart■ Slip compensation■ Automatic restart facility

    following power failure or fault

    ■ PI feedback for simple process control.

    ■ Programmable accelera-tion/deceleration, 0 s to 650 s

    ■ Ramp smoothing■ Fast current limit (FCL) for

    trip free operation■ Fast, repeatable digital

    input response time■ Fine speed adjustment

    using a high resolution 10 bit analog input

    ■ Compound braking for rapid controlled braking

    ■ Four skip frequencies■ Removable “Y” capacitor

    for use on IT mains supplies (with non-grounded mains supplies, the “Y” capacitor must be removed, and an output choke installed).

    ■ Overload current 1.5 x rated output current(i.e. 150 % overload capa-bility) for 60 s, cycle time 300 s

    ■ Overvoltage/undervoltage protection

    ■ Inverter overtemperature protection

    ■ Motor protection using PTC via digital input (possible with supplementary circuit)

    ■ Earth fault protection■ Short circuit protection■ I2t motor thermal protection■ Locked motor protection■ Stall prevention■ Parameter interlock.

    Description

  • Siemens DA 51.2 · 20022/4

    MICROMASTER 420

    2

    ■General Circuit Diagram

    5

    6

    7

    8

    9

    1

    2

    3

    4

    24 V+

    -

    DIN1

    DIN2

    DIN3

    AIN+

    AIN-

    RL1-B

    RL1-C

    AOUT+

    AOUT-

    P+

    N-

    10

    11

    12

    13

    14

    15

    RL1

    +10 V

    0 V

    M3~

    DA51-5003h

    A

    D

    A

    D

    CPU

    PE

    PE

    FS1

    PE

    U, V, W

    P

    I Fn

    O Jog

    +

    -

    Voltage supply

    Output relay contacts250 V AC, max. 2 A(inductive load)30 V DC, max. 5 A(resistive load)

    Analog output0 mA to 20 mA

    0 V (isolated)

    Operator panel (Option)

    Voltage supply and analog input

    Input voltage: 0 V to + 10 V, scalable

    A

    Serialinter-faceRS-485

    L, N (L1, L2)orL1, L2, L3

    4.7 kΩ->

    200 V to 240 V 1/3 AC380 V to 480 V 3 AC

    max. 33 Vmax. 5 mA

    +24 V (max.100 mA)DC Link

    AC

    DC

    DC

    AC

    2

    3

    4

    DIN4

    0 V

    9

    DA51-5004e

    +

    -

    0 V (isolated)

    For an additional digital input (DIN4)external connections should be made:

    A

    24 V

    Circuit Diagram

  • Siemens DA 51.2 · 2002 2/5

    MICROMASTER 420

    2

    ■Terminal Connection Diagram

    5 7 86 9

    1 3 42

    10 11

    RL1-B RL1-C

    +10 V 0 V AIN+ AIN-

    12 14 1513

    AOUT+ AOUT- P+ N-

    DA

    51

    -50

    06d

    DIN1 DIN2 DIN3 +24 V 0 V

    Output relayRL1

    Analog output RS-485(USS protocol)

    Voltagesupply 10 V

    Analog input

    Output relay contacts

    Digital inputs Voltagesupply 24 V

    (isolated)

    A

    View A

    View A

    Mainsconnection

    Motor connection

    DC link connection

    Example frame size A

    Circuit Diagram

  • Siemens DA 51.2 · 20022/6

    MICROMASTER 420

    2

    ■MICROMASTER 420 inverter

    Input voltage and power ranges

    200 V to 240 V 1 AC ± 10% 0.12 kW to 3 kW200 V to 240 V 3 AC ± 10% 0.12 kW to 5.5 kW380 V to 480 V 3 AC ± 10% 0.37 kW to 11 kW

    Input frequency 47 Hz to 63 HzOutput frequency 0 Hz to 650 Hz Power factor ³ 0.95Inverter efficiency 96% to 97%Overload capability Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s,

    cycle time 300 sInrush current less than rated input currentControl method linear V/f; quadratic V/f; multipoint characteristic (programmable V/f); flux current control (FCC)PWM frequency 16 kHz (standard with 230 V 1/3 AC)

    4 kHz (standard with 400 V 3 AC)2 kHz to 16 kHz (in 2 kHz steps)

    Fixed frequencies 7, programmableSkip frequency bands 4, programmableSetpoint resolution 0.01 Hz digital

    0.01 Hz serial10 bit analog

    Digital inputs 3 fully programmable isolated digital inputs; switchable PNP/NPNAnalog input 1 for setpoint or PI controller (0 to 10 V, scalable or for use as 4th digital input)Relay output 1, configurable 30 V DC/5 A (resistive), 250 V AC/2 A (inductive)Analog output 1, configurable (0 mA to 20 mA)Serial interfaces RS-485, optional RS-232Motor cable length

    without output choke

    with output choke

    max. 50 m (shielded)max. 100 m (unshielded)max. 200 m (shielded)max. 300 m (unshielded)

    Electromagnetic compatibility

    Inverter available with internal EMC filter Class A;available as options are EMC filters to EN 55 011, Class A or Class B

    Braking DC Braking, Compound BrakingProtection level IP 20Temperature range –10 °C to +50 °CStorage temperature –40 °C to +70 °CHumidity 95% (non-condensing)Operational altitudes up to 1000 m above sea level without deratingProtection features for • under-voltage

    • over-voltage• overload• earth faults • short circuits• stall prevention • locked motor • motor over-temperature • inverter over-temperature• parameter PIN protection

    Conformity with standards u, cu, >, c-tick ●✔> marking Conformity with EC low voltage directive 73/23/EC;

    filtered versions also with electromagnetic compatibility directive 89/336/ECDimensions and weights(without options)

    Frame size (FS) H x W x D (mm) Weight, approx. (kg)A 173 x 73 x 149 1.0B 202 x 149 x 172 3.3C 245 x 185 x 195 5.0

    Technical Data

  • Siemens DA 51.2 · 2002 2/7

    MICROMASTER 420

    2

    ■Derating DataPulse frequency

    Operating temperature

    Installation height above sea level

    Rated output(for 400 V 3 AC)

    Rated output current in Afor a pulse frequency of

    kW 4 kHz 6 kHz 8 kHz 10 kHz 12 kHz 14 kHz 16 kHz0.37 1.2 1.2 1.2 1.2 1.2 1.2 1.10.55 1.6 1.6 1.6 1.6 1.6 1.6 1.10.75 2.1 2.1 2.1 2.1 1.6 1.6 1.11.1 3.0 3.0 2.7 2.7 1.6 1.6 1.11.5 4.0 4.0 2.7 2.7 1.6 1.6 1.12.2 5.9 5.9 5.1 5.1 3.6 3.6 2.63.0 7.7 7.7 5.1 5.1 3.6 3.6 2.64.0 10.2 10.2 6.7 6.7 4.8 4.8 3.65.5 13.2 13.2 13.2 13.2 9.6 9.6 7.57.5 18.4 18.4 13.2 13.2 9.6 9.6 7.5

    11 26.0 26.0 17.9 17.9 13.5 13.5 10.4

    30

    60

    -10 0 700

    20

    40

    20

    80

    DA51-5017d

    100

    10

    %

    605040 °C

    50

    Rat

    ed o

    utpu

    t cur

    rent

    Operating temperature

    A

    Operating temperature

    Permissible output currentin % of the rated output current

    2000

    60

    0 40000

    20

    40

    80

    DA51-5018c

    100

    1000

    %

    3000 m

    Rat

    ed o

    utpu

    t cur

    rent

    Operational altitude

    A

    2000

    60

    0 40000

    20

    40

    80

    DA51-5019b

    100

    1000

    %

    3000 m

    77

    Mai

    ns v

    olta

    ge

    Operational altitude

    A

    Permissible mains voltagein % of the max. possible mains voltage

    Technical Data

  • Siemens DA 51.2 · 20022/8

    MICROMASTER 420

    2

    ■MICROMASTER 420 Inverter

    Rated output Rated input current 1)

    Rated output current

    Frame size Order No.

    kW hp A A (FS)

    MICROMASTER 420without filter

    MICROMASTER 420with Class A filter 2)

    Mains operating voltage 200 V to 240 V 1 AC 0.12 0.16 1.4 0.9 A 6SE6420-2UC11-2AA0 6SE6420-2AB11-2AA00.25 0.33 2.7 1.7 A 6SE6420-2UC12-5AA0 6SE6420-2AB12-5AA00.37 0.50 3.7 2.3 A 6SE6420-2UC13-7AA0 6SE6420-2AB13-7AA00.55 0.75 5.0 3.0 A 6SE6420-2UC15-5AA0 6SE6420-2AB15-5AA00.75 1.0 6.6 3.9 A 6SE6420-2UC17-5AA0 6SE6420-2AB17-5AA01.1 1.5 9.6 5.5 B 6SE6420-2UC21-1BA0 6SE6420-2AB21-1BA01.5 2.0 13.0 7.4 B 6SE6420-2UC21-5BA0 6SE6420-2AB21-5BA02.2 3.0 17.6 10.4 B 6SE6420-2UC22-2BA0 6SE6420-2AB22-2BA03.0 4.0 23.7 13.6 C 6SE6420-2UC23-0CA0 6SE6420-2AB23-0CA0

    Mains operating voltage 200 V to 240 V 3 AC 0.12 0.16 0.6 0.9 A 6SE6420-2UC11-2AA0 –0.25 0.33 1.1 1.7 A 6SE6420-2UC12-5AA0 –0.37 0.50 1.6 2.3 A 6SE6420-2UC13-7AA0 –0.55 0.75 2.1 3.0 A 6SE6420-2UC15-5AA0 –0.75 1.0 2.9 3.9 A 6SE6420-2UC17-5AA0 –1.1 1.5 4.1 5.5 B 6SE6420-2UC21-1BA0 –1.5 2.0 5.6 7.4 B 6SE6420-2UC21-5BA0 –2.2 3.0 7.6 10.4 B 6SE6420-2UC22-2BA0 –3.0 4.0 10.5 13.6 C 6SE6420-2UC23-0CA0 6SE6420-2AC23-0CA04.0 5.0 13.1 17.5 C 6SE6420-2UC24-0CA0 6SE6420-2AC24-0CA05.5 7.5 17.5 22.0 C 6SE6420-2UC25-5CA0 6SE6420-2AC25-5CA0

    Mains operating voltage 380 V to 480 V 3 AC 0.37 0.50 1.1 1.2 A 6SE6420-2UD13-7AA0 –0.55 0.75 1.4 1.6 A 6SE6420-2UD15-5AA0 –0.75 1.0 1.9 2.1 A 6SE6420-2UD17-5AA0 –1.1 1.5 2.8 3.0 A 6SE6420-2UD21-1AA0 –1.5 2.0 3.9 4.0 A 6SE6420-2UD21-5AA0 –2.2 3.0 5.0 5.9 B 6SE6420-2UD22-2BA0 6SE6420-2AD22-2BA03.0 4.0 6.7 7.7 B 6SE6420-2UD23-0BA0 6SE6420-2AD23-0BA04.0 5.0 8.5 10.2 B 6SE6420-2UD24-0BA0 6SE6420-2AD24-0BA05.5 7.5 11.6 13.2 C 6SE6420-2UD25-5CA0 6SE6420-2AD25-5CA07.5 10.0 15.4 19.0 C 6SE6420-2UD27-5CA0 6SE6420-2AD27-5CA0

    11 15.0 22.5 26.0 C 6SE6420-2UD31-1CA0 6SE6420-2AD31-1CA0

    See Appendix for note on ordering.

    All MICROMASTER 420 are supplied with a Status Display Panel SDP. A Basic Operator Panel BOP, Advanced Opera-tor Panel AOP or other options have to be ordered addition-ally (see pages 2/11 to 2/15).

    ■Motors forMICROMASTER 420

    Catalog M 11 contains selec-tion and ordering data for motors which are particularly suitable for operation with the MICROMASTER 420 inverters (see Appendix for overview).

    1) The values apply to rated mains voltages of 240 V or 400 V.

    2) Use of MICROMASTER invert-ers with internal filter is not permissible on non-grounded (IT) mains supplies.

    Selection and Ordering Data

  • Siemens DA 51.2 · 2002 2/9

    MICROMASTER 420

    2

    ■Variant Dependent OptionsEMC filter, Class A

    Filter for inverters without an internal filter, for– 200 V to 240 V 3 AC,

    frame sizes A and B– 380 V to 480 V 3 AC,

    frame size A.

    All other inverters can be supplied with an internal Class A filter.

    The requirements are fulfilled using shielded cables with a max. length of 25 m.

    EMC filter, Class B

    Filter for inverters without an internal filter, for– 200 V to 240 V 3 AC,

    frame sizes A and B– 380 V to 480 V 3 AC,

    frame size A.

    With this filter, the inverter complies with the emission standard EN 55 011, Class B.

    The requirements are fulfilled using shielded cables with a max. length of 25 m.

    Additional EMC filter, Class B

    Obtainable for inverters with an internal Class A EMC filter A.

    With this filter, the inverter complies with the emission standard EN 55 011, Class B.

    The requirements are fulfilled using shielded cables with a max. length of 25 m.

    Class B filter with low leakage currents

    EMC filter for 200 V to 240 V 1 AC inverters, frame sizes A and B, without an internal (Class A) EMC filter.

    With this filter, the inverter complies with the emission standard EN 55 011, Class B. The leakage currents are reduced to < 3.5 mA.

    The requirements are fulfilled using shielded cables with a max. length of 5 m.

    Leakage currents:

    The leakage currents of the inverters with/without filter (internal/external) may exceed 30 mA. Typical values in practice are between 10 mA and 50 mA. The exact values depend on the design, envi-ronment and cable lengths. Interference-free operation with residual current operated devices with a trigger value of 30 mA cannot be guaranteed. However, operation with resid-ual current operated devices with a trigger value of 300 mA is possible. Please refer to the Instruction Manual for details.

    Line commutating choke

    Line commutating chokes are used to smooth voltage peaks or to bridge commutating dips. In addition, line commu-tating chokes reduce the effects of harmonics on the inverter and the power supply. If the line impedance is < 1%, a line commutating choke must be used in order to reduce the current peaks.

    In line with the EN 61 000-3-2 regulations “Limits for har-monic currents with device input current £ 16 A per phase”, there are special aspects for drives with 250 W to 550 W and 230-V single-phase supplies which can be used in non-industrial applica-tions (1st environment).

    For devices with 250 W and 370 W it is necessary either to fit the recommended input chokes or to apply to the power utility company for authorization to connect the devices to the public power supply. No limits are currently defined in the EN 61 000-3-2 standard for professionally used devices with a connected load > 1 kW. This means that the inverters with an output power ³ 0.75 kW comply with the EN 61 000-3-2 standard.

    Output choke

    Output chokes can be supplied for reducing the capacitive currents and dV/dt in the case of motor cables > 50 m (shielded) or > 100 m (unshielded).

    Gland plate

    The gland plate enables shielded connection of the power and control cables, ensuring optimum EMC performance. This ensures compliance with the NEMA1 directive.

    Options

  • Siemens DA 51.2 · 20022/10

    MICROMASTER 420

    2

    ■Variant Independent OptionsBasic Operator Panel (BOP)

    With the BOP, individual parameter settings can be made. Values and units are shown on a 5-digit display.

    Basic Operator Panel (BOP)

    A BOP can be used for several inverters. It can be directly mounted on the inverter or in a control-cabinet door using a mounting kit.

    Advanced Operator Panel (AOP)

    The AOP enables parameter sets to be read out of the inverter or to be written into the inverter (upload/download). Different parameter sets can be stored in the AOP. It has a plain-text display with the pos-sibility of switching between several languages.

    Advanced Operator Panel (AOP)

    Up to 30 inverters can be con-trolled from an AOP via USS protocol. It can be directly plugged into the inverter or built into the control-cabinet door using a mounting kit.

    PROFIBUS module

    For a complete PROFIBUS connection with up to 12 Mbaud. Remote control of the inverter is possible with the PROFIBUS module. Remote control and operation at the inverter can be combined using an operator panel – plugged onto the PROFIBUS module. The latter can be sup-plied by an external 24 V DC power supply and is thus also active when the inverter is dis-connected from the mains.

    Connection by means of a 9-pin SUB-D connector (available as an accessory).

    DeviceNet module

    For networking the inverters to the DeviceNet fieldbus system widely used on the American market. A max. transmission rate of 500 kbaud is possible. Remote control of the module is possible via the DeviceNet module. Remote control and operation on the inverter can be combined using an opera-tor panel connected to the DeviceNet module.

    The connection to the DeviceNet bus system is made using a 5-pin connector with terminal strip.

    Connection set forPC to inverter

    For controlling an inverter directly from a PC if the appro-priate software has been installed (e.g. STARTER) in the PC. Isolated RS-232 adapter board for reliable point-to-point connection to a PC. Includes a Sub-D connector and an RS-232 standard cable (3 m).

    Connection set forPC to AOP

    For connecting a PC to an AOP. Offline programming of inverters and archiving of parameter sets possible. Includes a desktop attach-ment kit for an AOP, an RS-232 standard cable (3 m) with Sub-D connectors and a uni-versal power supply unit.

    Operator panel door mounting kit for single inverter control

    For mounting an operator panel in a control cabinet door. Degree of protection is IP 56. Contains a cable adapter board with screwless terminals for use with the user‘s own cables.

    AOP door mounting kit for multiple inverter control (USS)

    For mounting an AOP in a control cabinet door. Degree of protection IP 56. The AOP can communicate with several inverters by means of the RS-485 USS protocol. The 4-pin connecting cable from the AOP to the RS-485 termi-nals of the inverter and to the 24 V user terminal strip is not included.

    Commissioning tools

    • STARTER Starter is start-up software for guided commissioning for MICROMASTER 410/420/430/440 frequency inverters under Windows NT/2000. Parameter lists can be read out, altered, stored, entered and printed.

    • DriveMonitorDriveMonitor is start-up software for list-oriented programming of frequency inverters under Windows 95/98/NT/2000.

    Both programs are included on the Docu CD which is pro-vided with every inverter.

    Options

  • Siemens DA 51.2 · 2002 2/11

    MICROMASTER 420

    2

    ■Ordering Data for Variant Dependent OptionsThe options listed here (filters, chokes, gland plates, fuses and circuit breakers) are inverter specific.

    The inverter and the associ-ated options have the same voltage ratings.

    All options are certified to u, except fuses. The fuses of type 3NA3 are recommended for Europe.

    Use in America requires u-listed fuses such as e.g. the Class NON range from Bussmann.

    Mains operating voltage

    Rated output

    Inverterwithout filter

    Order No. of the options

    kWEMC filterClass A

    EMC filterClass B

    Supplementary EMC filter Class B

    200 V to 240 V 1 AC 0.12 6SE6420-2UC11-2AA0 – – –0.25 6SE6420-2UC12-5AA0 – – –0.37 6SE6420-2UC13-7AA0 – – –0.55 6SE6420-2UC15-5AA0 – – –0.75 6SE6420-2UC17-5AA0 – – –1.1 6SE6420-2UC21-1BA0 – – –1.5 6SE6420-2UC21-5BA0 – – –2.2 6SE6420-2UC22-2BA0 – – –3.0 6SE6420-2UC23-0CA0 – – –

    200 V to 240 V 3 AC 0.12 6SE6420-2UC11-2AA0 6SE6400-2FA00-6AD0 6SE6400-2FB00-6AD0 –0.25 6SE6420-2UC12-5AA0 –0.37 6SE6420-2UC13-7AA0 –0.55 6SE6420-2UC15-5AA0 –0.75 6SE6420-2UC17-5AA0 –1.1 6SE6420-2UC21-1BA0 6SE6400-2FA01-4BC0 6SE6400-2FB01-4BC0 –1.5 6SE6420-2UC21-5BA0 –2.2 6SE6420-2UC22-2BA0 –3.0 6SE6420-2UC23-0CA0 – – –4.0 6SE6420-2UC24-0CA0 – – –5.5 6SE6420-2UC25-5CA0 – – –

    380 V to 480 V 3 AC 0.37 6SE6420-2UD13-7AA0 6SE6400-2FA00-6AD0 6SE6400-2FB00-6AD0 –0.55 6SE6420-2UD15-5AA0 –0.75 6SE6420-2UD17-5AA0 –1.1 6SE6420-2UD21-1AA0 –1.5 6SE6420-2UD21-5AA0 –2.2 6SE6420-2UD22-2BA0 – – –3.0 6SE6420-2UD23-0BA0 – – –4.0 6SE6420-2UD24-0BA0 – – –5.5 6SE6420-2UD25-5CA0 – – –7.5 6SE6420-2UD27-5CA0 – – –

    11 6SE6420-2UD31-1CA0 – – –Inverter with internal filter Class A

    200 V to 240 V 1 AC 0.12 6SE6420-2AB11-2AA0 – – 6SE6400-2FS01-0AB00.25 6SE6420-2AB12-5AA0 – –0.37 6SE6420-2AB13-7AA0 – –0.55 6SE6420-2AB15-5AA0 – –0.75 6SE6420-2AB17-5AA0 – –1.1 6SE6420-2AB21-1BA0 – – 6SE6400-2FS02-6BB01.5 6SE6420-2AB21-5BA0 – –2.2 6SE6420-2AB22-2BA0 – –3.0 6SE6420-2AB23-0CA0 – – 6SE6400-2FS03-5CB0

    200 V to 240 V 3 AC 3.0 6SE6420-2AC23-0CA0 – – 6SE6400-2FS03-8CD04.0 6SE6420-2AC24-0CA0 – –5.5 6SE6420-2AC25-5CA0 – –

    380 V to 480 V 3 AC 2.2 6SE6420-2AD22-2BA0 – – 6SE6400-2FS01-6BD03.0 6SE6420-2AD23-0BA0 – –4.0 6SE6420-2AD24-0BA0 – –5.5 6SE6420-2AD25-5CA0 – – 6SE6400-2FS03-8CD07.5 6SE6420-2AD27-5CA0 – –

    11 6SE6420-2AD31-1CA0 – –

    Options

  • Siemens DA 51.2 · 20022/12

    MICROMASTER 420

    2

    ■Ordering Data for Variant Dependent Options (continued)

    Mains operating voltage

    Rated output

    Inverterwithout filter

    Order No. of the options

    kWLow leakageClass B

    Line commutatingchoke

    Output choke

    200 V to 240 V 1 AC 0.12 6SE6420-2UC11-2AA0 6SE6400-2FL01-0AB0 6SE6400-3CC00-4AB0 6SE6400-3TC00-4AD00.25 6SE6420-2UC12-5AA00.37 6SE6420-2UC13-7AA0 6SE6400-3CC01-0AB00.55 6SE6420-2UC15-5AA00.75 6SE6420-2UC17-5AA01.1 6SE6420-2UC21-1BA0 6SE6400-2FL02-6BB0 6SE6400-3CC02-6BB0 6SE6400-3TC01-0BD01.5 6SE6420-2UC21-5BA02.2 6SE6420-2UC22-2BA03.0 6SE6420-2UC23-0CA0 – 6SE6400-3CC03-5CB0 6SE6400-3TC03-2CD0

    200 V to 240 V 3 AC 0.12 6SE6420-2UC11-2AA0 – 6SE6400-3CC00-3AC0 6SE6400-3TC00-4AD00.25 6SE6420-2UC12-5AA0 –0.37 6SE6420-2UC13-7AA0 – 6SE6400-3CC00-5AC00.55 6SE6420-2UC15-5AA0 –0.75 6SE6420-2UC17-5AA0 –1.1 6SE6420-2UC21-1BA0 – 6SE6400-3CC00-8BC0 6SE6400-3TC01-0BD01.5 6SE6420-2UC21-5BA0 – 6SE6400-3CC01-4BD02.2 6SE6420-2UC22-2BA0 –3.0 6SE6420-2UC23-0CA0 – 6SE6400-3CC01-7CC0 6SE6400-3TC03-2CD04.0 6SE6420-2UC24-0CA0 – 6SE6400-3CC03-5CD05.5 6SE6420-2UC25-5CA0 –

    380 V to 480 V 3 AC 0.37 6SE6420-2UD13-7AA0 – 6SE6400-3CC00-2AD0 6SE6400-3TC00-4AD00.55 6SE6420-2UD15-5AA0 –0.75 6SE6420-2UD17-5AA0 – 6SE6400-3CC00-4AD01.1 6SE6420-2UD21-1AA0 –1.5 6SE6420-2UD21-5AA0 – 6SE6400-3CC00-6AD02.2 6SE6420-2UD22-2BA0 – 6SE6400-3CC01-0BD0 6SE6400-3TC01-0BD03.0 6SE6420-2UD23-0BA0 –4.0 6SE6420-2UD24-0BA0 – 6SE6400-3CC01-4BD05.5 6SE6420-2UD25-5CA0 – 6SE6400-3CC02-2CD0 6SE6400-3TC03-2CD07.5 6SE6420-2UD27-5CA0 –

    11 6SE6420-2UD31-1CA0 – 6SE6400-3CC03-5CD0Inverter with internal filter Class A

    200 V to 240 V 1 AC 0.12 6SE6420-2AB11-2AA0 – 6SE6400-3CC00-4AB0 6SE6400-3TC00-4AD00.25 6SE6420-2AB12-5AA0 –0.37 6SE6420-2AB13-7AA0 – 6SE6400-3CC01-0AB00.55 6SE6420-2AB15-5AA0 –0.75 6SE6420-2AB17-5AA0 –1.1 6SE6420-2AB21-1BA0 – 6SE6400-3CC02-6BB0 6SE6400-3TC01-0BD01.5 6SE6420-2AB21-5BA0 –2.2 6SE6420-2AB22-2BA0 –3.0 6SE6420-2AB23-0CA0 – 6SE6400-3CC03-5CB0 6SE6400-3TC03-2CD0

    200 V to 240 V 3 AC 3.0 6SE6420-2AC23-0CA0 – 6SE6400-3CC01-7CC0 6SE6400-3TC03-2CD04.0 6SE6420-2AC24-0CA0 – 6SE6400-3CC03-5CD05.5 6SE6420-2AC25-5CA0 –

    380 V to 480 V 3 AC 2.2 6SE6420-2AD22-2BA0 – 6SE6400-3CC01-0BD0 6SE6400-3TC01-0BD03.0 6SE6420-2AD23-0BA0 –4.0 6SE6420-2AD24-0BA0 – 6SE6400-3CC01-4BD05.5 6SE6420-2AD25-5CA0 – 6SE6400-3CC02-2CD0 6SE6400-3TC03-2CD07.5 6SE6420-2AD27-5CA0 –

    11 6SE6420-2AD31-1CA0 – 6SE6400-3CC03-5CD0

    Options

  • Siemens DA 51.2 · 2002 2/13

    MICROMASTER 420

    2

    ■Ordering Data for Variant Dependent Options (continued)

    Mains operating voltage

    Rated output

    Inverterwithout filter

    Order No. of the options

    kWGland plate Fuse

    (see Catalog NS K)Circuit breaker(see Catalog NS K)

    200 V to 240 V 1 AC 0.12 6SE6420-2UC11-2AA0 6SE6400-0GP00-0AA0 3NA3803 3RV1021-1CA100.25 6SE6420-2UC12-5AA0 3RV1021-1FA100.37 6SE6420-2UC13-7AA0 3RV1021-1HA100.55 6SE6420-2UC15-5AA0 3RV1021-1JA100.75 6SE6420-2UC17-5AA0 3NA3805 3RV1021-1KA101.1 6SE6420-2UC21-1BA0 6SE6400-0GP00-0BA0 3NA3807 3RV1021-4BA101.5 6SE6420-2UC21-5BA0 3RV1021-4DA102.2 6SE6420-2UC22-2BA0 3NA3810 3RV1031-4EA103.0 6SE6420-2UC23-0CA0 6SE6400-0GP00-0CA0 3NA3812 3RV1031-4GA10

    200 V to 240 V 3 AC 0.12 6SE6420-2UC11-2AA0 6SE6400-0GP00-0AA0 3NA3803 3RV1021-0JA100.25 6SE6420-2UC12-5AA0 3RV1021-1CA100.37 6SE6420-2UC13-7AA0 3RV1021-1DA100.55 6SE6420-2UC15-5AA0 3RV1021-1FA100.75 6SE6420-2UC17-5AA0 3RV1021-1GA101.1 6SE6420-2UC21-1BA0 6SE6400-0GP00-0BA0 3NA3805 3RV1021-1HA101.5 6SE6420-2UC21-5BA0 3RV1021-1JA102.2 6SE6420-2UC22-2BA0 3NA3807 3RV1021-4AA103.0 6SE6420-2UC23-0CA0 6SE6400-0GP00-0CA0 3NA3810 3RV1021-4BA104.0 6SE6420-2UC24-0CA0 3NA3812 3RV1021-4DA105.5 6SE6420-2UC25-5CA0 3NA3814 3RV1031-4FA10

    380 V to 480 V 3 AC 0.37 6SE6420-2UD13-7AA0 6SE6400-0GP00-0AA0 3NA3803 3RV1021-1CA100.55 6SE6420-2UD15-5AA0 3RV1021-1DA100.75 6SE6420-2UD17-5AA0 3RV1021-1EA101.1 6SE6420-2UD21-1AA0 3RV1021-1GA101.5 6SE6420-2UD21-5AA0 3RV1021-1HA102.2 6SE6420-2UD22-2BA0 6SE6400-0GP00-0BA0 3NA3805 3RV1021-1JA103.0 6SE6420-2UD23-0BA0 3RV1021-1KA104.0 6SE6420-2UD24-0BA0 3NA3807 3RV1021-4AA105.5 6SE6420-2UD25-5CA0 6SE6400-0GP00-0CA0 3RV1021-4CA107.5 6SE6420-2UD27-5CA0 3NA3810 3RV1031-4EA10

    11 6SE6420-2UD31-1CA0 3NA3814 3RV1031-4FA10Inverter with internal filter Class A

    200 V to 240 V 1 AC 0.12 6SE6420-2AB11-2AA0 6SE6400-0GP00-0AA0 3NA3803 3RV1021-1CA100.25 6SE6420-2AB12-5AA0 3RV1021-1FA100.37 6SE6420-2AB13-7AA0 3RV1021-1HA100.55 6SE6420-2AB15-5AA0 3RV1021-1JA100.75 6SE6420-2AB17-5AA0 3NA3805 3RV1021-1KA101.1 6SE6420-2AB21-1BA0 6SE6400-0GP00-0BA0 3NA3807 3RV1021-4BA101.5 6SE6420-2AB21-5BA0 3RV1021-4DA102.2 6SE6420-2AB22-2BA0 3NA3810 3RV1031-4EA103.0 6SE6420-2AB23-0CA0 6SE6400-0GP00-0CA0 3NA3812 3RV1031-4GA10

    200 V to 240 V 3 AC 3.0 6SE6420-2AC23-0CA0 6SE6400-0GP00-0CA0 3NA3810 3RV1021-4BA104.0 6SE6420-2AC24-0CA0 3NA3812 3RV1021-4DA105.5 6SE6420-2AC25-5CA0 3NA3814 3RV1031-4FA10

    380 V to 480 V 3 AC 2.2 6SE6420-2AD22-2BA0 6SE6400-0GP00-0BA0 3NA3805 3RV1021-1JA103.0 6SE6420-2AD23-0BA0 3RV1021-1KA104.0 6SE6420-2AD24-0BA0 3NA3807 3RV1021-4AA105.5 6SE6420-2AD25-5CA0 6SE6400-0GP00-0CA0 3RV1021-4CA107.5 6SE6420-2AD27-5CA0 3NA3810 3RV1031-4EA10

    11 6SE6420-2AD31-1CA0 3NA3814 3RV1031-4FA10

    Options

  • Siemens DA 51.2 · 20022/14

    MICROMASTER 420

    2

    ■Ordering Data for Variant Independent Options

    Technical data of the communications modules

    The options listed here are suitable for all MICROMASTER 420 Inverters.

    Options Order No. Basic Operator Panel (BOP) 6SE6400-0BP00-0AA0Advanced Operator Panel (AOP) 6SE6400-0AP00-0AA0

    6SE6400-0AP00-0AA1 (available from mid 2002)PROFIBUS module 6SE6400-1PB00-0AA0DeviceNet module 6SE6400-1DN00-0AA0RS485/PROFIBUS bus connector 6GK1500-0FC00Connection set for PC to inverter 6SE6400-1PC00-0AA0Connection set for PC to AOP 6SE6400-0PA00-0AA0Inverter-door mounting kit for single inverter control 6SE6400-0PM00-0AA0AOP-door mounting kit for multiple inverter control (USS) 6SE6400-0MD00-0AA0

    PROFIBUS module6SE6400-1PB00-0AA0

    DeviceNet module6SE6400-1DN00-0AA0

    Size (height x width x depth) 161 mm x 73 mm x 46 mmDegree of protection IP 20Degree of pollution 2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operationMechanical strength• Stationary

    • Transport

    DeflectionAccelerationDeflectionAcceleration

    to DIN IEC 60 068-2-6 (if module installed correctly) 0.15 mm in the frequency range of 10 Hz to 58 Hz19.6 m/s2 in the frequency range of 58 Hz to 500 Hz3.5 mm in the frequency range of 5 Hz to 9 Hz9.8 m/s2 in the frequency range of 9 Hz to 500 Hz

    Climatic category (during operation) 3K3 to DIN IEC 60 721-3-3Cooling method Natural air coolingPermissible ambient or cooling agent temperature• in operation• during storage and transport

    –10 °C to +50 °C (14 °F to 122 °F)–25 °C to +70 °C (–13 °F to 158 °F)

    Relative humidity (permissible humidity rating)• in operation• during storage and transport

    £ 85% (non-condensing)£ 95%

    Electromagnetic compatibility EmissionInterference radiation

    to EN 55 011 (1991) Class Ato IEC 60 801-3 and EN 61 000-4-3

    Supply voltage 6.5 V ± 5%, max. 300 mA, internal from inverter or 24 V ± 10%, max. 350 mA, external

    6.5 V ± 5%, max. 300 mAinternal from inverter and 24 V, max. 60 mA from DeviceNet bus

    Output voltage 5 V ± 10%, max. 100 mA,galvanically isolated supply• for terminating the serial interface bus or • for supplying the OLP (Optical Link Plug)

    Data transmission rate max. 12 Mbaud 125, 250 and 500 kbaud

    Options

  • Siemens DA 51.2 · 2002 2/15

    MICROMASTER 420

    2

    ■Documentation

    Type of documentation Language Order No.Docu-Pack,supplied with each inverter, containing CD-ROM 1) and Getting-Started Guide 2) (paper version)

    Multilanguage 6SE6400-5AB00-1AP0

    Operating instructions 2) (paper version)

    German 6SE6400-5AA00-0AP0English 6SE6400-5AA00-0BP0French 6SE6400-5AA00-0DP0Italian 6SE6400-5AA00-0CP0Spanish 6SE6400-5AA00-0EP0

    Parameter list 2)(paper version)

    German 6SE6400-5BA00-0AP0English 6SE6400-5BA00-0BP0

    1) The CD-ROM contains oper-ating instructions, parameter list, commissioning tools STARTER and DriveMonitor, multilanguage.

    2) Available on Internet at http://www.siemens.com/micromaster

    Options

  • Siemens DA 51.2 · 20022/16

    MICROMASTER 420

    2

    ■MICROMASTER 420 Inverter

    With the communications module, the mounting depth increases by 23 mm (0.91 inches).

    Frame size 200 V to 240 V 1/3 AC 380 V to 480 V 3 AC A 0.12 kW to 0.75 kW 0.37 kW to 1.5 kWB 1.1 kW to 2.2 kW 2.2 kW to 4 kWC 3 kW to 5.5 kW 5.5 kW to 11 kW

    Drill and fixing pattern

    DIN Rail

    AD

    A51

    -500

    0d

    160

    (6.2

    9)

    58(2

    .28)

    173

    (6.8

    1)

    147

    (57.

    87)

    73(2.87)

    149

    (5.87

    )

    Inverter frame size A

    Fixing with2 bolts M4, 2 nuts M4,2 washers M4or snap on to the DIN railTightening torque with washers fitted: 2.5 NmVentilation clearance required at top and bottom: 100 mm

    AD

    A51

    -500

    7c

    195

    (7.6

    8)

    Inverter frame size Awith gland plate

    Drill pattern

    AD

    A51

    -500

    2d

    185 (7.28)

    245

    (9.6

    5)

    195

    (7.68

    )

    204

    (8.0

    3)

    174 (6.85)

    Fixing with4 bolts M5, 4 nuts M5,4 washers M5Tightening torque with washers fitted: 3.0 NmVentilation clearance required at top and bottom: 100 mm

    Inverter frame size C

    AD

    A51

    -500

    9b

    309

    (12.

    16)

    Inverter frame size Cwith gland plate

    Drill pattern

    AD

    A51

    -500

    1d

    174

    (6.8

    5)

    138 (5.43)

    202

    (7,9

    5)

    149 (5.87)

    172

    (6.77

    ) Fixing with4 bolts M4, 4 nuts M4,4 washers M4Tightening torque with washers fitted: 2.5 NmVentilation clearance required at top and bottom: 100 mm

    Inverter frame size BA

    DA

    51-5

    008b

    258

    (10.

    16)

    Inverter frame size Bwith gland plate

    All dimensions are in mm (values in brackets are in inches)

    Dimension Drawings

  • Siemens DA 51.2 · 2002 2/17

    MICROMASTER 420

    2

    ■Filters and Chokes

    b

    DA

    51-5

    013e

    c

    a

    Line commutating choke for frame size A for frame sizes B and C

    DA

    51-5

    014d

    b

    a

    c

    Linecommutatingchoke for

    Dim. Weight (max.)

    a b c kgframe size A 200

    (7.87)75.5(2.97)

    50(1.97)

    0.8

    frame size B 213(8.39)

    150(5.91)

    50(1.97)

    1.3

    frame size C 245(9.65)

    185(7.28)

    50(1.97)

    2.3

    AD

    A51

    -501

    0e

    2 x M4

    160

    (6.3

    )

    5673

    200

    (7.8

    7)

    174

    (6.8

    5)18

    7 (7

    .36)

    (2.2)(2.87)

    42.5 (1.67)

    23.5(0.93)

    Filter for frame size A for frame size B

    AD

    A51

    -501

    2c

    4 x M5

    204

    (8.0

    3)

    156 (6.14)185 (7.28)38

    (1.5)

    245

    (9.6

    5)

    54 (2.13)

    219

    (8.6

    2)23

    2 (9

    .13)

    174(6.85)

    AD

    A51

    -501

    1c

    4 x M417

    4 (6

    .85)

    120 (4.72)149 (5.87)

    213

    (8.3

    9)

    187

    (7.3

    6)20

    0 (7

    .87)

    138(5.43)

    49.5 (1.95)

    24(0.94)

    for frame size C

    All dimensions are in mm (values in brackets are in inches)

    b

    DA

    51-5

    049

    c

    a

    Output choke for frame size A for frame sizes B and C

    DA

    51-5

    050

    b

    a

    c

    Outputchoke for

    Dim. Weight (max.)

    a b c kgframe size A 200

    (7.87)75.5(2.97)

    50(1.97)

    0.8

    frame size B 213(8.39)

    150(5.91)

    70(2.76)

    3.4

    frame size C 245(9.65)

    185(7.28)

    80(3.15)

    5.6

    Dimension Drawings

  • Siemens DA 51.2 · 20022/18

    MICROMASTER 420

    2

    ■Assembly of inverter and options

    DA

    51-5

    016b

    Example: Assembly of inverter, choke and filterIf additional accessories are required, they must be mounted at the side.

    Dimension Drawings

  • Siemens DA 51.2 · 2002 3/1

    3

    InverterMICROMASTER 430

    3/2 Description

    3/4 Circuit Diagrams

    3/6 Technical Data

    3/8 Selection and Ordering Data

    3/9 Options

    3/14 Dimension Drawings

  • Siemens DA 51.2 · 20023/2

    MICROMASTER 430

    3■Applications ■Main Characteristics ■Options (Overview) ■ International Standards

    The MICROMASTER 430 inverter is suitable for a variety of variable-speed drive appli-cations. Its flexibility provides for a wide spectrum of appli-cations. It is especially suit-able for use with industrial pumps and fans. The inverter is especially characterized by its customer-oriented perfor-mance and ease of use. It has more inputs and outputs than the MICROMASTER 420, an optimized operator panel with manual/automatic switchover, and adapted software func-tionality.

    ■DesignThe MICROMASTER 430 inverter has a modular design.

    The operator panels and communications modules can be easily exchanged.

    ■ Simple commissioning■ Modular construction

    allows maximum configura-tion flexibility

    ■ Six programmable isolated digital inputs

    ■ Two scalable analog inputs (0 V to 10 V, 0 mA to 20 mA) can also be used as a 7th/8th digital input

    ■ Two programmable analog outputs (0 mA to 20 mA)

    ■ Three fully programmable relay outputs(30 V DC/5 A, resistive250 V AC/2 A, inductive)

    ■ Silent motor operation is selectable when using high switching frequencies (observe derating if neces-sary)

    ■ Complete inverter and motor protection

    ■ Control of up to three addi-tional drives on the basis of PID control (motor staging)

    ■ Operation of drive directly on mains (with external bypass circuit)

    ■ Energy saving mode■ Detects running-dry of

    pumps (belt failure detection).

    ■ Line commutating chokes■ Output chokes■ Gland plates ■ BOP basic operator panel 2

    (BOP-2) for parameterizing an inverter

    ■ Communications modules– PROFIBUS– DeviceNet

    ■ PC connection kits■ Assembly kits for mounting

    the operator panels in the control cabinet doors

    ■ PC commissioning tools, running under Windows 95/98 and NT/2000.

    ■ The MICROMASTER 430 inverter complies with the requirements of the EU low-voltage guideline; filtered versions also comply with the EU EMC guideline

    ■ The MICROMASTER 430 inverter has the > marking

    ■ u and cu listed■ c-tick ●✔

    Note:

    See Appendix for standards.

    Description

  • Siemens DA 51.2 · 2002 3/3

    MICROMASTER 430

    3

    ■Mechanical Features ■Performance Features ■Protection Features■ Modular design■ Operating temperature:

    –10 °C to +40 °C■ Compact housing as a

    result of high power density■ Easy cable connection,

    mains and motor connec-tions are separated for optimum electromagnetic compatibility

    ■ Detachable operator panels

    ■ Screwless control terminals on detachable I/O board.

    ■ Latest IGBT technology■ Digital microprocessor

    control■ Flux current control (FCC)

    for improved dynamic response and optimized motor control

    ■ Linear V/f characteristic■ Quadratic V/f characteristic■ Multipoint characteristic

    (programmable V/f charac-teristic)

    ■ Flying restart■ Slip compensation■ Automatic restart facility

    following power failure or fault

    ■ Energy saving mode (stopping e.g. of a pump at low speeds)

    ■ Motor staging (connection and disconnection of additional motors, use of inverter as control drive in a pump cascade)

    ■ Manual/automatic mode■ Load torque detection

    (detects running-dry of pumps)

    ■ High-grade PID controller for simple process control

    ■ Programmable accelera-tion/deceleration,0 s to 650 s

    ■ Ramp smoothing■ Fast current limit (FCL) for

    trip free operation■ Fast, repeatable digital

    input response time■ Fine speed adjustment

    using two high resolution 10-bit analog inputs

    ■ Compound braking for rapid controlled braking

    ■ Four skip frequencies■ Removable “Y” capacitor

    for use on IT mains supplies (with non-grounded mains supplies, the “Y” capacitor must be removed, and an output choke installed).

    ■ Overload capability– VT mode

    Overload current 1.4 x rated output current(i.e. 140 % overload capability) for 3 s and 1.1 x rated output current (i.e. 110 % overload capability) for 60 s, cycle time 300 s

    ■ Overvoltage/undervoltage protection

    ■ Inverter overtemperature protection

    ■ Special direct connection for PTC or KTY to protect the motor

    ■ Earth fault protection■ Short circuit protection■ I2t motor thermal protection■ Locked motor protection■ Stall prevention■ Parameter interlock.

    Description

  • Siemens DA 51.2 · 20023/4

    MICROMASTER 430

    3

    ■General Circuit Diagram

    D

    A

    D

    D

    A

    M3~

    PE

    1

    2

    3

    4

    AIN1+

    AIN1-

    +10 V

    0 V

    10

    11

    AIN2+

    AIN2-

    DIN1

    DIN2

    DIN3

    5

    6

    7DIN4

    DIN5

    DIN6

    8

    16

    17

    9

    28

    PNP

    NPN

    PTC A

    PTC B14

    15

    AOUT1+

    AOUT1-12

    13

    AOUT2+

    AOUT2-26

    27

    RL1 - C20

    19

    18

    22

    21

    25

    24

    23

    P+29

    N-30

    RS485

    CPU

    PE

    PE

    FS1

    60 Hz

    50 Hz1 2

    AIN1 AIN2

    0 - 10 V

    0 - 20 mA

    DIN 7

    1

    2

    3

    4DIN 8

    1

    2

    10

    11

    DA51-5048b

    1 2

    A

    D

    A

    RL2

    RL3

    RL1 - B

    RL1 - A

    RL2 - C

    RL2 - B

    RL3 - C

    RL3 - B

    RL3 - A

    U, V, W

    RL1

    P

    I Fn

    O

    L1, L2, L3

    Operator panel (Option)

    Opto isolation

    or

    Output +24 V (isolated)

    Output 0 V (isolated)

    Output relaycontacts250 V AC, max. 2 A(inductive load)30 V DC, max. 5 A(resistive load)

    For additional digital inputs(DIN 7, DIN 8) external connections should be made:

    Notes: When an analog input is configured as a digital input the threshold values are as follows:

    1.75 V DC = off3.7 V DC = on

    AIN1: 0 V to 10 V, 0 mA to 20 mA and -10 V to +10 V AIN2: 0 V to 10 V and 0 mA to 20 mA

    DIP Switches(on I/O Board)

    Notused

    DIP Switches(on Control Board)

    A

    4.7 kΩ->

    Motor PTC

    0 - 20 mA,max. 500 Ω

    0 - 20 mA,max. 500 Ω

    BOPSerial

    Protocol

    380 to 480 V 3 AC

    DC

    AC

    AC

    DC

    Circuit Diagrams

  • Siemens DA 51.2 · 2002 3/5

    MICROMASTER 430

    3

    ■Terminal Connection Diagram

    22 24 252318 20 2119

    27 29 302818 17 261612 14 1513

    8 10 11918 6 751 3 42

    RL1-A RL2-BRL1-B RL1-C RL2-C RL3-A RL3-B RL3-C

    AOUT1+ AOUT1- P+ N-DIN5 DIN6 AOUT2+ AOUT2-PTCA

    PTCB

    PE0 V

    +10 V 0 V AIN1+ AIN1- DIN1 DIN2 DIN3 DIN4 AIN2+ AIN2-+24 V

    S2S1

    (DIN7) (DIN8)

    DA

    51-5

    025

    AIN1 AIN2

    DIP Switches:0 mA to 20 mA or0 V to 10 V

    Output relay contacts

    Analog output 1 Digital inputs Analog output 2 RS-485(USS-protocol)

    Voltagesupply 10 V

    Digital inputsAnalog input 1 Analog input 2

    A

    *) PNP or NPN possible

    NPN *)

    PNP *)

    View A

    Example frame size C

    View A

    Mainsconnections

    Motorconnections

    Circuit Diagrams

  • Siemens DA 51.2 · 20023/6

    MICROMASTER 430

    3

    ■MICROMASTER 430 Inverter

    Input voltage and power ranges 380 V to 480 V 3 AC ± 10% 7.5 kW to 90 kW (variable torque)Input frequency 47 Hz to 63 HzOutput frequency 0 Hz to 650 Hz Power factor ³ 0.95Inverter efficiency 96 % to 97 %Overload capability Overload current 1.4 x rated output current (i.e. 140 % overload capability) for 3 s and

    1.1 x rated output current (i.e. 110 % overload capability) for 60 s, cycle time 300 s Inrush current less than rated input currentControl method linear V/f; quadratic V/f; multipoint characteristic (programmable V/f);

    flux current control (FCC), energy saving modePWM frequency 4 kHz (standard)

    2 kHz to 16 kHz (in 2 kHz steps)Fixed frequencies 15, programmableSkip frequency bands 4, programmableSetpoint resolution 0.01 Hz digital

    0.01 Hz serial10 bit analog

    Digital inputs 6 fully programmable isolated digital inputs; switchable PNP/NPNAnalog inputs 2 programmable analog inputs

    • 0 V to 10 V, 0 mA to 20 mA and –10 V to +10 V (AIN1)• 0 V to 10 V and 0 mA to 20 mA (AIN2)• both can be used as 7th/8th digital input

    Relay outputs 3, configurable, 30 V DC/5 A (resistive), 250 V AC/2 A (inductive)Analog outputs 2, programmable (0/4 mA to 20 mA)Serial interfaces RS-485, Option RS-232Motor cable length

    without output choke

    with output choke

    max. 50 m (shielded)max. 100 m (unshielded)max. 200 m (shielded)max. 300 m (unshielded)

    Electromagnetic compatibility Optional EMC filters to EN 55 011, Class B (for frame size C), Inverter with internal filter Class A available

    Braking DC Braking, Compound BrakingProtection level IP 20Temperature range –10 °C to +40 °CStorage temperature –40 °C to +70 °CRelative humidity 95% (non-condensing)Installation height up to 1000 m above sea level without deratingProtection features for • under-voltage

    • over-voltage• overload• earth faults • short circuits• stall prevention • locked motor • motor over-temperature • inverter over-temperature• parameter PIN protection

    Conformity with standards u, cu, >, c-tick ●✔> marking Conformity with EC low voltage directive 73/23/EC

    filtered versions also with electromagnetic compatibility directive 89/336/ECDimensions and weights(without options)

    Frame size (FS)CDEF without filterF with filter

    H x W x D, max. (mm)245 x 185 x 195520 x 275 x 245650 x 275 x 245850 x 350 x 320

    1150 x 350 x 320

    Weight, approx. (kg)5.7

    17225675

    Technical Data

  • Siemens DA 51.2 · 2002 3/7

    MICROMASTER 430

    3

    ■Derating DataPulse frequency

    Operating temperature

    Installation height above sea level

    Rated output (for 400 V 3 AC)

    Rated output current in Afor a pulse frequency of

    kW 4 kHz 6 kHz 8 kHz 10 kHz 12 kHz 14 kHz 16 kHz7.5 19.0 17.1 15.2 13.3 11.4 9.5 7.6

    11.0 26.0 24.7 23.4 20.8 18.2 15.6 13.015.0 32.0 28.8 25.6 22.4 19.2 16.0 12.818.5 38.0 36.1 34.2 30.4 26.6 22.8 19.022 45.0 40.5 36.0 31.5 27.0 22.5 18.030 62.0 55.8 49.6 43.4 37.2 31.0 24.837 75.0 71.3 67.5 60.0 52.5 45.0 37.545 90.0 81.0 72.0 63.0 54.0 45.0 36.055 110.0 93.5 77.0 63.3 49.5 41.3 33.075 145.0 123.3 101.5 83.4 65.3 54.4 43.590 178.0 138.0 97.9 84.6 71.2 62.3 53.4

    60

    0

    20

    40

    80

    DA51-5045

    100%

    50

    300 2010 5040 °C-10

    Rat

    ed o

    utpu

    t cu

    rren

    t

    Operating temperature

    A

    Permissible output currentin % of the rated output current

    2000

    60

    0 40000

    20

    40

    80

    DA51-5018c

    100

    1000

    %

    3000 m

    Rat

    ed o

    utpu

    t cur

    rent

    Operational altitude

    A

    2000

    60

    0 40000

    20

    40

    80

    DA51-5019b

    100

    1000

    %

    3000 m

    77

    Mai

    ns v

    olta

    ge

    Operational altitude

    A

    Permissible mains voltagein % of the max. possible mains voltage

    Technical Data

  • Siemens DA 51.2 · 20023/8

    MICROMASTER 430

    3

    ■MICROMASTER 430 Inverter

    Rated output Rated input current 1)

    Rated outputcurrent

    Frame size Ordering No.

    kW hp A A (FS)

    MICROMASTER 430without filter

    MICROMASTER 430with internal filter Class A 2)

    Mains operating voltage 380 V to 480 V 3 AC 7.5 10 16.0 19 C 6SE6430-2UD27-5CA0 6SE6430-2AD27-5CA0

    11.0 15 22.5 26 C 6SE6430-2UD31-1CA0 6SE6430-2AD31-1CA015.0 20 30.5 32 C 6SE6430-2UD31-5CA0 6SE6430-2AD31-5CA018.5 25 37.2 38 D 6SE6430-2UD31-8DA0 6SE6430-2AD31-8DA022 30 43.3 45 D 6SE6430-2UD32-2DA0 6SE6430-2AD32-2DA030 40 59.3 62 D 6SE6430-2UD33-0DA0 6SE6430-2AD33-0DA037 50 71.7 75 E 6SE6430-2UD33-7EA0 6SE6430-2AD33-7EA045 60 86.6 90 E 6SE6430-2UD34-5EA0 6SE6430-2AD34-5EA055 75 103.6 110 F 6SE6430-2UD35-5FA0 6SE6430-2AD35-5FA075 100 138.5 145 F 6SE6430-2UD37-5FA0 6SE6430-2AD37-5FA090 120 168.5 178 F 6SE6430-2UD38-8FA0 6SE6430-2AD38-8FA0

    See Appendix for note on ordering.

    All MICROMASTER 430 inverters are supplied with a Status Display Panel SDP. A BOP-2 or other options have to be ordered additionally (see pages 3/11 to 3/13).

    ■Motors forMICROMASTER 430

    Catalog M 11 contains selec-tion and ordering data for motors which are particularly suitable for operation with the MICROMASTER 430 inverters (see Appendix for overview).

    1) Additional conditions:input current at nominal working point, applies to short-circuit voltage of mains supply Vk ³ 1 % referred to rated inverter power and rated mains voltage of 400 V.

    2) Use of MICROMASTER invert-ers with internal filter is not permissible on non-grounded mains supplies.

    Selection and Ordering Data

  • Siemens DA 51.2 · 2002 3/9

    MICROMASTER 430

    3

    ■Variant Dependent OptionsEMC filter, Class A

    All other inverters can be supplied with an internal filter Class A.

    The requirements are fulfilled using shielded cables with a max. length of 25 m.

    Additional EMC filter, Class B

    Obtainable for inverters with an internal EMC filter Class A, frame size C.

    With this filter, the inverter complies with the emission standard EN 55 011, Class B.

    The requirements are fulfilled using shielded cables with a max. length of 25 m.

    Leakage currents:

    The leakage currents of the inverters with/without filter (internal/external) may exceed 30 mA. Typical values in practice are between 10 mA and 50 mA. The exact values depend on the design, envi-ronment and cable lengths. Interference-free operation with residual current operated devices with a trigger value of 30 mA cannot be guaranteed. However, operation with resid-ual current operated devices with a trigger value of 300 mA is possible. Please refer to the Instruction Manual for details.

    Line commutating choke

    Line commutating chokes are used to smooth voltage peaks or to bridge commutating dips. In addition, line commu-tating chokes reduce the effects of harmonics on the inverter and the power supply. If the line impedance is < 1%, a line commutating choke must be used in order to reduce the current peaks.

    No limits are currently defined in the EN 61 000-3-2 standard for professionally used devices with a connected load > 1 kW. This means that the inverters with an output power ³ 0.75 kW comply with the EN 61 000-3-2 standard.

    Output choke

    Output chokes can be supplied for reducing the capacitive currents and dV/dt in the case of motor cables > 50 m (shielded) or > 100 m (unshielded).

    Gland plate

    Gland plates are available for inverters with frame size C. In frame sizes D, E and F, the gland plates are integrated.

    The gland plate enables shielded connection of the power and control cables, ensuring optimum EMC performance. This action ensures compliance with the NEMA1 directive.

    ■Variant Independent OptionsBasic Operator Panel 2 (BOP-2)

    With the BOP-2, individual parameter settings can be made. Values and units are shown on a 5-digit display.

    Basic Operator Panel (BOP-2)

    A BOP-2 can be used for several inverters. It can be directly mounted on the inverter or in a control-cabinet door using a mounting kit.

    PROFIBUS module

    For a complete PROFIBUS connection with up to 12 Mbaud. Remote control of the inverter is possible with the PROFIBUS module. Remote control and operation at the inverter can be combined using an operator panel – plugged onto the PROFIBUS module. The latter can be sup-plied by an external 24 V DC power supply and is thus also active when the inverter is dis-connected from the mains.

    Connection by means of a 9-pin SUB-D connector (available as an accessory).

    DeviceNet module

    For networking the inverters to the DeviceNet fieldbus system widely used on the American market. A max. transmission rate of 500 kbaud is possible. Remote control of the module is possible via the DeviceNet module.

    Remote control and operation on the inverter can be com-bined using an operator panel connected to the DeviceNet module.

    The connection to the DeviceNet bus system is made using a 5-pin connector with terminal strip.

    Connection set forPC to inverter

    For controlling an inverter directly from a PC if the appropriate software has been installed (e.g. STARTER) in the PC. Isolated RS-232 adapter board for reliable point-to-point connection to a PC. Includes a Sub-D connec-tor and an RS-232 standard cable (3 m).

    Operator panel door mounting kit for single inverter control

    For mounting an operator panel in a control cabinet door. Degree of protection is IP 56. Contains a cable adapter board with screwless terminals for use with the user‘s own cables.

    Commissioning tools

    • STARTER Starter is start-up software for guided commissioning for MICROMASTER 410/420/430/440 frequency inverters under Windows NT/2000. Parameter lists can be read out, altered, stored, entered and printed.

    • DriveMonitorDriveMonitor is start-up software for list-oriented programming of frequency inverters under Windows 95/98/NT/2000.

    Both programs are included on the Docu CD which is provided with every inverter.

    Options

  • Siemens DA 51.2 · 20023/10

    MICROMASTER 430

    3

    ■Ordering Data for Variant Dependent OptionsThe options listed here (filters, chokes, gland plates, fuses and circuit breakers) are inverter specific.

    The inverter and the associ-ated options have the same voltage ratings.

    All options are certifiedto u, except fuses. The fuses 3NE1 comply with u (corresponds to U).

    Mains operating voltage

    Rated output

    Inverterwithout filter

    Order No. of the options

    kWLine commutating choke

    Output choke Gland plates

    380 V to 480 V 3 AC 7.5 6SE6430-2UD27-5CA0 6SE6400-3CC02-2CD0 6SE6400-3TC03-2CD0 6SE6400-0GP00-0CA011.0 6SE6430-2UD31-1CA015.0 6SE6430-2UD31-5CA0 6SE6400-3CC03-5CD018.5 6SE6430-2UD31-8DA0 6SE6400-3CC04-4DD0 6SE6400-3TC05-4DD0 Integrated as standard22 6SE6430-2UD32-2DA0 6SE6400-3TC03-8DD030 6SE6430-2UD33-0DA0 6SE6400-3CC05-2DD0 6SE6400-3TC05-4DD037 6SE6430-2UD33-7EA0 6SE6400-3CC08-3ED0 6SE6400-3TC08-0ED045 6SE6430-2UD34-5EA0 6SE6400-3TC07-5ED055 6SE6430-2UD35-5FA0 6SE6400-3CC11-2FD0 6SE6400-3TC14-5FD075 6SE6430-2UD37-5FA0 6SE6400-3TC15-4FD090 6SE6430-2UD38-8FA0 6SE6400-3CC11-7FD0 6SE6400-3TC14-5FD0

    Mains operating voltage

    Rated output

    Inverterwithout filter

    Order No. of the options

    Fuse (see Catalog NS K) Circuit breaker(see Catalog NS K)kW 3NA3 3NE1 (U)

    380 V to 480 V 3 AC 7.5 6SE6430-2UD27-5CA0 3NA3007 l 3RV1031-4EA1011.0 6SE6430-2UD31-1CA0 3NA3012 3RV1031-4FA1015.0 6SE6430-2UD31-5CA0 3NA3014 3RV1031-4HA1018.5 6SE6430-2UD31-8DA0 3NA3020 3NE1817-0 3RV1042-4KA1022 6SE6430-2UD32-2DA0 3NA3022 3NE1818-030 6SE6430-2UD33-0DA0 3NA3024 3NE1820-0 3RV1042-4MA1037 6SE6430-2UD33-7EA0 3NA3030 3NE1021-0 3VL1712- . DD33- . . . . 45 6SE6430-2UD34-5EA0 3NA3032 3NE1022-0 3VL1716- . DD33- . . . . 55 6SE6430-2UD35-5FA0 3NA3036 3NE1224-0 3VL3720- . DC36- . . . . 75 6SE6430-2UD37-5FA0 3NE1225-0 3VL3725- . DC36- . . . . 90 6SE6430-2UD38-8FA0 3NA3140 3VL4731- . DC36- . . . .

    l Use in America requires u-listed fuses such as e.g. the Class NON range from Bussmann.

    Options

  • Siemens DA 51.2 · 2002 3/11

    MICROMASTER 430

    3

    ■Ordering Data for Variant Dependent Options (continued)

    Mains operating voltage

    Rated output

    Inverterwith internal filter Class A

    Order No. of the options

    kWLine commutating choke

    Output choke

    380 V to 480 V 3 AC 7.5 6SE6430-2AD27-5CA0 6SE6400-3CC02-2CD0 6SE6400-3TC03-2CD011.0 6SE6430-2AD31-1CA015.0 6SE6430-2AD31-5CA0 6SE6400-3CC03-5CD018.5 6SE6430-2AD31-8DA0 6SE6400-3CC04-4DD0 6SE6400-3TC05-4DD022 6SE6430-2AD32-2DA0 6SE6400-3TC03-8DD030 6SE6430-2AD33-0DA0 6SE6400-3CC05-2DD0 6SE6400-3TC05-4DD037 6SE6430-2AD33-7EA0 6SE6400-3CC08-3ED0 6SE6400-3TC08-0ED045 6SE6430-2AD34-5EA0 6SE6400-3TC07-5ED055 6SE6430-2AD35-5FA0 6SE6400-3CC11-2FD0 6SE6400-3TC14-5FD075 6SE6430-2AD37-5FA0 6SE6400-3TC15-4FD090 6SE6430-2AD38-8FA0 6SE6400-3CC11-7FD0 6SE6400-3TC14-5FD0

    Mains operating voltage

    Rated output

    Inverterwith internal filter Class A

    Order No. of the options

    Supplementary EMC filter, Class B

    Gland platekW

    380 V to 480 V 3 AC 7.5 6SE6430-2AD27-5CA0 6SE6400-2FS03-8CD0 6SE6400-0GP00-0CA011.0 6SE6430-2AD31-1CA015.0 6SE6430-2AD31-5CA018.5 6SE6430-2AD31-8DA0 – Integrated as standard22 6SE6430-2AD32-2DA0 –30 6SE6430-2AD33-0DA0 –37 6SE6430-2AD33-7EA0 –45 6SE6430-2AD34-5EA0 –55 6SE6430-2AD35-5FA0 –75 6SE6430-2AD37-5FA0 –90 6SE6430-2AD38-8FA0 –

    Mains operating voltage

    Rated output

    Inverterwith internal filter Class A

    Order No. of the options

    Fuse (see Catalog NS K) Circuit breaker(see Catalog NS K)kW 3NA3 3NE1 (U)

    380 V to 480 V 3 AC 7.5 6SE6430-2AD27-5CA0 3NA3007 l 3RV1031-4EA1011.0 6SE6430-2AD31-1CA0 3NA3012 3RV1031-4FA1015.0 6SE6430-2AD31-5CA0 3NA3014 3RV1031-4HA1018.5 6SE6430-2AD31-8DA0 3NA3020 3NE1817-0 3RV1042-4KA1022 6SE6430-2AD32-2DA0 3NA3022 3NE1818-030 6SE6430-2AD33-0DA0 3NA3024 3NE1820-0 3RV1042-4MA1037 6SE6430-2AD33-7EA0 3NA3030 3NE1021-0 3VL1712- . DD33- . . . . 45 6SE6430-2AD34-5EA0 3NA3032 3NE1022-0 3VL1716- . DD33- . . . . 55 6SE6430-2AD35-5FA0 3NA3036 3NE1224-0 3VL3720- . DC36- . . . . 75 6SE6430-2AD37-5FA0 3NE1225-0 3VL3725- . DC36- . . . . 90 6SE6430-2AD38-8FA0 3NA3140 3VL4731- . DC36- . . . .

    l Use in America requires u-listed fuses such as e.g. the Class NON range from Bussmann.

    Options

  • Siemens DA 51.2 · 20023/12

    MICROMASTER 430

    3

    ■Ordering Data for Variant Independent Options

    Technical data of the communications modules

    The options listed here are suitable for all MICROMASTER 430.

    Option Order No. Basic Operator Panel 2 (BOP-2) 6SE6400-0BE00-0AA0PROFIBUS module 6SE6400-1PB00-0AA0DeviceNet module 6SE6400-1DN00-0AA0RS485/PROFIBUS bus connector 6GK1500-0FC00Connection set for PC to inverter 6SE6400-1PC00-0AA0Operator panel door mounting kit for single inverter 6SE6400-0PM00-0AA0

    PROFIBUS module6SE6400-1PB00-0AA0

    DeviceNet module6SE6400-1DN00-0AA0

    Size (height x width x depth) 161 mm x 73 mm x 46 mmDegree of protection IP 20Degree of pollution 2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operationMechanical strength• Stationary

    • Transport

    DeflectionAccelerationDeflectionAcceleration

    to DIN IEC 60 068-2-6 (if module installed correctly) 0.15 mm in the frequency range of 10 Hz to 58 Hz19.6 m/s2 in the frequency range of 58 Hz to 500 Hz3.5 mm in the frequency range of 5 Hz to 9 Hz9.8 m/s2 in the frequency range of 9 Hz to 500 Hz

    Climatic category (during operation) 3K3 to DIN IEC 60 721-3-3Cooling method Natural air coolingPermissible ambient or cooling agent temperature• in operation• during storage and transport

    –10 °C to +50 °C (14 °F to 122 °F)–25 °C to +70 °C (–13 °F to 158 °F)

    Relative humidity (permissible humidity rating)• in operation• during storage and transport

    £ 85% (non-condensing)£ 95%

    Electromagnetic compatibility EmissionInterference radiation

    to EN 55 011 (1991) Class Ato IEC 60 801-3 and EN 61 000-4-3

    Supply voltage 6.5 V ± 5%, max. 300 mA, internal from inverter or 24 V ± 10%, max. 350 mA, external

    6.5 V ± 5%, max. 300 mAinternal from inverter and 24 V, max. 60 mA from DeviceNet bus

    Output voltage 5 V ± 10%, max. 100 mA,galvanically isolated supply• for terminating the serial interface bus or • for supplying the OLP (Optical Link Plug)

    Data transmission rate max. 12 Mbaud 125, 250 and 500 kbaud

    Options

  • Siemens DA 51.2 · 2002 3/13

    MICROMASTER 430

    3

    ■Documentation (available from 05/2002)

    Type of documentation Language Order No.Docu-Pack,supplied with each inverter, containing CD-ROM 1) and Getting Started Guide 2) (paper version)

    Multilanguage 6SE6400-5AE00-1AP0

    Operating instructions 2) (paper version)

    German 6SE6400-5AE00-0AP0English 6SE6400-5AE00-0BP0French 6SE6400-5AE00-0DP0Italian 6SE6400-5AE00-0CP0Spanish 6SE6400-5AE00-0EP0

    Parameter list 2)(paper version)

    German 6SE6400-5AF00-0AP0English 6SE6400-5AF00-0BP0French 6SE6400-5AF00-0DP0Italian 6SE6400-5AF00-0CP0Spanish 6SE6400-5AF00-0EP0

    1) The CD-ROM contains oper-ating instructions, parameter list, commissioning tools STARTER and DriveMonitor, multilanguage.

    2) Available on Internet at http://www.siemens.com/micromaster

    Options

  • Siemens DA 51.2 · 20023/14

    MICROMASTER 430

    3

    ■MICROMASTER 430 Inverter

    With the communications module the mounting depth increases with frame size C by 23 mm (0.91 inches).

    Frame size 380 V to 480 V 3 ACC 7.5 kW to 15 kWD 18.5 kW to 30 kWE 37 kW to 45 kWF 55 kW to 90 kW

    Drill pattern

    AD

    A51

    -500

    2d

    185 (7.28)

    245

    (9.6

    5)

    195

    (7.68

    )20

    4 (8

    .03)

    174 (6.85)

    Fixing with4 bolts M54 nuts M54 washers M5Tightening torque with washers fitted: 3.0 NmVentilation clearance required at top and bottom: 100 mm

    Inverter frame size C

    AD

    A51

    -500

    9b

    309

    (12.

    16)

    Inverter frame size Cwith gland plates

    All dimensions are in mm (values in brackets are in inches)

    Inverter frame size D Inverter frame size E

    520

    (20.

    47)

    275 (10.82)

    245

    (9.6

    5)

    486

    (19.

    13)

    Drill pattern

    AD

    A51

    -502

    0b

    235 (9.25)

    Drill pattern

    275 (10.82)

    650

    (25.

    59)

    245

    (9.6

    5)

    AD

    A51

    -502

    1b

    616.

    4 (2

    4.27

    )

    235 (9.25)

    Fixing with4 bolts M84 nuts M84 washers M8Tightening torque with washers fitted: 3.0 NmVentilation clearance required at top and bottom: 300 mm

    Fixing with4 bolts M84 nuts M84 washers M8Tightening torque with washers fitted: 3.0 NmVentilation clearance required at top and bottom: 300 mm

    Dimension Drawings

  • Siemens DA 51.2 · 2002 3/15

    MICROMASTER 430

    3

    All dimensions are in mm (values in brackets are in inches)

    Inverter frame size F without filter Inverter frame size F with filter

    AD

    A51

    -502

    2b

    850

    (33.

    46)

    350 (13.78)

    320

    (12.

    6)

    810

    (31.

    89)

    300 (11.81)

    Drill pattern

    AD

    A51

    -502

    3b

    350 (13.78)

    320

    (12.

    6)

    300 (11.81)

    Drill pattern

    1050

    (45

    .28)

    1110

    (43

    .70)

    Fixing with4 bolts M84 nuts M84 washers M8Tightening torque with washers fitted: 3.0 NmVentilation clearance required at top and bottom: 350 mm

    Fixing with4 bolts M84 nuts M84 washers M8Tightening torque with washers fitted: 3.0 NmVentilation clearance required at top and bottom: 350 mm

    Dimension Drawings

  • Siemens DA 51.2 · 20023/16

    MICROMASTER 430

    3

    ■Filters and Chokes

    AD

    A51

    -501

    2c4 x M5

    204

    (8.0

    3)

    156 (6.14)185 (7.28)38

    (1.5)

    245

    (9.6

    5)

    54 (2.13)

    219

    (8.6

    2)23

    2 (9

    .13)

    174(6.85)

    Filter for frame size C

    All dimensions are in mm (values in brackets are in inches)

    DA

    51-5

    051

    b

    a

    c

    Line commutating choke for frame sizes D and E

    Line commutatingchoke for

    Dim. Weight (max.)

    a b c kgframe size D 520

    (20.47)275(10