Ultralow temperature freezers -86°C Platilab & Irilab Series

Ultralow temperature freezers -86°C Platilab & Irilab Seriessiteadm.angelantoni.it/Media/brc/BRC_0528.pdf · Chest and upright freezers operating at -86°C, designed for long term

  • Upload
    others

  • View
    106

  • Download
    3

Embed Size (px)

Citation preview

Page 1: Ultralow temperature freezers -86°C Platilab & Irilab Seriessiteadm.angelantoni.it/Media/brc/BRC_0528.pdf · Chest and upright freezers operating at -86°C, designed for long term

Ultr

alow

tem

pera

ture

free

zers

-86°

C P

latil

ab &

Irila

b Se

ries

Page 2: Ultralow temperature freezers -86°C Platilab & Irilab Seriessiteadm.angelantoni.it/Media/brc/BRC_0528.pdf · Chest and upright freezers operating at -86°C, designed for long term

ANGELANTONI LIFE SCIENCE propose a wide range of -86°C ultralow temperature freezers, from 110 to 800 liters, chests and uprights kind. This brochure includes all -86°C ULT freezers available at ALS for storage of general non-flammable materials, for laboratories use, pharmaceutical, hospital and for any other kind of storage when such a low temperature is required.

PLATILAB models have the classic insulation with high density injected CFC-free PU foam of minimum 140 mm thickness

IRILAB models have a mix of vacuum insulated panels (V.I.P.) and injected PU foam for total 70 mm thickness. This solution increases the internal capacity by consuming less footprint area.

NEXT versions of both PLATILAB and IRILAB have the intelligent controller Cold Brain™

Page 3: Ultralow temperature freezers -86°C Platilab & Irilab Seriessiteadm.angelantoni.it/Media/brc/BRC_0528.pdf · Chest and upright freezers operating at -86°C, designed for long term

Chest and upright freezers operating at -86°C, designed for long term storage of general non-flammable materials

Stainless steel interiors

Racks for classic fibercard boxes for vials storage are available for all models (optional)

CO2 / LN2 back systems (optional)

Remote alarms standard

Auto recharging battery backup to feed the electronics up to 36 h in case of main power off

Doors key lock or push button or by personal card opening system (see option BIOGUARD™)

Inner doors are standard in all models

Two kind of microprocessor controllers, both battery buffered: • The standard controller has two independent sections, one for the cooling system and one

for the alarms

• The ColdBrain™ controller, installed with all NEXT versions, includes a full monitoring

system of the freezer’ performance. ColdBrain™ has an internal temperature graph

recorder, alarms and touch key buttons too. Besides the Cold Brain™ is ready for Ethernet

connection and is supplied with a SD memory card for local data storage (requires

CRYOLOG software to read SD memory data: see optional accessories for computer

communication)

3

Ultralow temperature freezers -86°CPlatilab & Irilab Series

550 L

520 L 340 L 370 L 110 L800 L

Page 4: Ultralow temperature freezers -86°C Platilab & Irilab Seriessiteadm.angelantoni.it/Media/brc/BRC_0528.pdf · Chest and upright freezers operating at -86°C, designed for long term

Operating temperature range: -50°C to -86°C

4

PLATILAB : 140 mm insulation of HD Injected PU Foam IRILAB : 70 mm insulation with vacuum panels and PU foamStandard porthole with cap (diam. 23 mm) included with all models

Heavy frame with:• Exterior in galvanized steel epoxy coated powder,• Stainless steel interior with rounded corners• Inner Doors • Adjustable Shelves (upright models only)• High resistance castors

Main door:• With magnetic double tight gasket• Easy one hand opening system• PLATILAB: key lock as standard or key card opening system (see options BIOGUARD)• IRILAB: push button as standard or key card opening system (see options BIOGUARD)• NEXT versions: push button or Bioguard™ (see options BIOGUARD)• Vent valve to reduce the waiting time from a door opening to another

Cooling system:• Static with two high performance compressors (cascade system)• CFC free gases• Low noise level • Removable front filter for easy cleaning (upright models only)

Technical features

Ultralow temperature freezers -86°CPlatilab & Irilab Series

Page 5: Ultralow temperature freezers -86°C Platilab & Irilab Seriessiteadm.angelantoni.it/Media/brc/BRC_0528.pdf · Chest and upright freezers operating at -86°C, designed for long term

Standard controller for PLATILAB and IRILAB series.

Intelligent controller for PLATILAB Next and IRILAB Next

The standard controller is made of two independent parts: one for the cooling system control and another one for all local and remote alarms. It is equipped with rechargeable battery back-up which can provide energy to the electronics up to 48h even in case of power black-outs. The standard controller can be equipped with an optional Ethernet board, for connection and data handling to the CRYOLOG software (See optional accessories).

The ColdBrain™ microcontroller uses a back lighted LCD graphic display of 240 x 128 pixels with a touch keyboard and 3 independent electronics: one for power & temperature management, one for the alarms, and one for the display, communication and data logging.A self-diagnostic routine it’s full time active to double check both electronic sections and to avoid data loss.

Cooling system:

• Temperature setting• Temperature display• Cooling system ON/OFF

Power & Temperature management section:

• Temperature setting• Cooling system ON/OFF• Power diagnostic view by two Pt100 and two NTC probes

Alarms section:

• Alarms setting for Hi-Low temperature• Door ajar• Main power-off• Acoustic and visual alarms with LEDs• Free contacts for remote alarms

Alarms section:

• Hi-Low temperature• Door ajar• Main power-off or out of range• Free contacts for remote alarms• Compressors failure• Alarms diagnostic view by two Pt100 and two NTC probes• Probes failure• Battery back-up handling, and battery low• LCO2/LN2 back-up system handling

Display, communication and data logging section:

• Temperature and alarms display • Acoustic & visual alarms with LEDs• Temperature graph on display for last twelve weeks• Password protected settings• Password protected memory card (SD) for graphs, alarms and data• Ethernet port with configurable TCP/IP address• Data communication failure• Connection with CRYOLOG Data Management Software• BIOGUARD handling, recording of accesses and failure detection

(if available)

ColdBrain™

Equipment /Controllers

5

Page 6: Ultralow temperature freezers -86°C Platilab & Irilab Seriessiteadm.angelantoni.it/Media/brc/BRC_0528.pdf · Chest and upright freezers operating at -86°C, designed for long term

12086

12084

13071

12083

13070

13113

PLATILAB 110 H

PLATILAB 550 H

PLATILAB 500 V-4-STD

PLATILAB 370 H

PLATILAB 340 V-4-STD

IRILAB 800V-5-STD

230VAC50Hz 7.0FLA

230VAC50Hz 7.0FLA

230VAC50Hz 9.0FLA

230VAC50Hz 7.0FLA

230VAC50Hz 7.0FLA

230VAC50Hz 9.0FLA

Chest PU HD

Chest PU HD

UprightPU HD

Chest PU HD

UprightPU HD

Upright V.I.P.

-50° to -86°C

-50° to -86°C

-50° to -86°C

-50° to -86°C

-50° to -86°C

-50° to -86°C

1

3

4

2

4

5

none

none

3

none

3

4

6300

33000

40000

21000

24000

60000

110

550

500

370

340

800

450x560x450

1590x520x670

700x530x1350

1050x520x670

450x530x1350

906x609x1472

730x850x1080

2350x855x1140

1015x900x1985

1780x855x1140

765x900x1985

1086x890x1995

800x1020x1270

2380x970x1300

1080x1000x2120

1850x970x1300

800x950x2150

1151x990x2120

CodeModel with

standard controller

ElectricalVersion and insulation

kind

Operatingrange In

ner

door

s

Shel

ves Max vials

capacity2 ml

Volumeliters

InteriordimensionsWxDxH mm

ExteriordimensionsWxDxH mm

PackagedimensionsWxDxH mm

Net weight *with pack.

180 *205 Kg

312 *360 Kg

300 *329 Kg

260 *299 Kg

234 *262 Kg

364 *389 Kg

CodeModel withColdbrain™ controller

ElectricalVersion and insulation

kind

Operatingrange In

ner

door

s

Shel

ves Max vials

capacity2 ml

Volumeliters

InteriordimensionsWxDxH mm

ExteriordimensionsWxDxH mm

PackagedimensionsWxDxH mm

Net weight *with pack.

13343

13340

13334

13259

13338

13341

PLATILAB NEXT 500 V-4-STD

PLATILAB NEXT 550 H

IRILAB NEXT 800V-5-STD

PLATILAB NEXT 370 H

IRILAB NEXT 520V-4-STD

PLATILAB NEXT 340 V-4-STD

230VAC50Hz 9.0FLA

230VAC50Hz 7.0FLA

230VAC50Hz 9.0FLA

230VAC50Hz 7.0FLA

230VAC50Hz 9.0FLA

230VAC50Hz 7.0FLA

UprightPU HD

Chest PU HD

Upright V.I.P.

Chest PU HD

Upright V.I.P.

UprightPU HD

-50° to -86°C

-50° to -86°C

-50° to -86°C

-50° to -86°C

-50° to -86°C

-50° to -86°C

4

3

5

2

4

4

3

none

4

none

3

3

40000

33000

60000

21000

38400

24000

500

550

800

370

520

340

700x530x1350

1590x520x670

906x609x1472

1050x520x670

586x613x1470

450x530x1350

1015x900x1985

2350x855x1140

1086x890x1995

1780x855x1140

730x845x1980

765x900x1985

1080x1000x2120

2380x970x1300

1151x990x2120

1850x970x1300

800x950x2150

800x950x2150

301 *329 Kg

312 *360 Kg

364 *389 Kg

260 *299 Kg

260 *290 Kg

236 *262 Kg

Technical specifications

NOTE: All models are available upon request for 230 or 120 VAC, 60Hz

Code Description

12124

13804

Cryolog™ monitoring software for Windows computers (see details on last page too)

Ethernet connection board necessary only for STD versions (NEXT versions include as standard the Ethernet board)

Optional Accessories for computer communication

IMPORTANT NOTES:

1. To connect a freezer to the computer where Cryolog™ is installed, please provide by yourself for two Ethernet cables of proper length and one Ethernet Switch: one cable is for freezer – Switch connection and one is for Switch computer connection

2. If you have more than one freezer to put on line, please buy as many Ethernet cables of proper length as the number of freezers you have and Ethernet Switch with sufficient numbers of ports equal or greater than the number of freezers plus one (last one free to be used for computer connection).

Example of computer interfaces of CRYOLOG software - see specific section: “CRYOLOG data management software”

6

Page 7: Ultralow temperature freezers -86°C Platilab & Irilab Seriessiteadm.angelantoni.it/Media/brc/BRC_0528.pdf · Chest and upright freezers operating at -86°C, designed for long term

11930

12278

13353

12107

13354

13355

CO2 back-up system for PLATILAB 340V, 500V and IRILAB 520, 800V

CO2 back-up system for PLATILAB 110H, 370H and 550H

CO2 back-up system for PLATILAB NEXT 340V, 500V, IRILAB NEXT 520V and 800V

LN2 back-up system with hose for all models except IRILAB NEXT 520V and 800V

CO2 back-up system for PLATILAB NEXT 370H and 550H

LN2 back-up system with hose only for IRILAB NEXT 520V and 800V

Cryogenic back-up systems

Code Description

General accessories for PLATILAB and IRILAB versions

11352

12293

11976

12132

13233

13804

7-days temperature chart recorder (pen + diagrams for 1 year)

Kit for chart recorder (100 discs and 2 pens)

Additional user badge for BIOGUARD system

Additional certified PT 100 temperature probe, class A with 3 calibration points

Additional PT 100 temperature probe class A

Ethernet board (only for PLATILAB and IRILAB STD, request Cryolog™ swr for computer connection)

Code Description

LCO2 / LN2 cryogenic back-up systems to automatically supply liquid nitrogen or carbon dioxide into the freezers. In case of chamber warm up beyond - 65°C, the system automatically injects the liquid gas, to keep the internal temperature around -65°C. These back-up systems include the probes, the electronics and the cryogenic valves. The cryogenic cylinders with LN2 or LCO2 are not included and must be locally provided through a qualified supplier, as well as the connection piping. The LCO2 / LN2 are emergency devices only. In none case, they can replace the job of the cooling systems. The task of such emergency systems, it is to ensure few hours extra at a reasonably low temperature, even in case of compressors failure or mains power black-out. The few hours ensured by the back-up systems represent the time necessary to move the freezer contents into another working unit until the electric power is back. This time may differ significantly depending on several factors: kind and quantity of cryogen gas availability, freezer filling volume and external ambient temperature.

LCO2 - example of connection diagram of a LCO2 complete back-up system

-86° C FREEZER

BIOGUARD™ system uses RFID cards to open the door without key. Each unit equipped with the Bioguard™ is supplied complete with three opening cads but in addition to that, You may add some more cards (optional). The BIOGUARD option increase the safety of your valuable stored products. In case of card damaging or electronic failure, there is an emergency rescue key to open the door manually.

BIOGUARD™

12680 BIOGUARD™ - RFID card door opening system, fits any models except PLATILAB 110 H

7

Page 8: Ultralow temperature freezers -86°C Platilab & Irilab Seriessiteadm.angelantoni.it/Media/brc/BRC_0528.pdf · Chest and upright freezers operating at -86°C, designed for long term

Storage racks for chest freezers, for boxes with sizes of 129x129x 50 H mm PLATILAB HORIZONTAL

11685

11687

Code Description Dimension mm Storage capacity 110 L 370 L 550 L

Vertical without boxes

Vertical without boxes

W140xD135xH391

W138xD138xH603

Boxes per rackRaks per freezers

Boxes per rackRaks per freezers

79

n/an/a

n/an/a

1021

n/an/a

1033

Storage racks for chest freezers, for boxes with sizes of 129x129x 75 H mm PLATILAB HORIZONTAL

11686

11688

Code Description Dimension mm Storage capacity 110 L 370 L 550 L

Vertical without boxes

Vertical without boxes

W140xD135xH391

W138xD138xH603

Boxes per rackRaks per freezers

Boxes per rackRaks per freezers

59

n/an/a

n/an/a

721

n/an/a

733

Racks for vial storage

13365

13228

13231

Storage racks for upright freezers, for boxes with sizes of 129x129x 50 H mm PLATILAB VERT. IRILAB VERT.

Horizontal without boxes

Horizontal without boxes

Horizontal without boxes

W130xD544xH281

W130xD544xH266

W130xD544xH319

Boxes per rackRaks per freezers

Boxes per rackRaks per freezers

Boxes per rackRaks per freezers

2012

n/an/a

n/an/a

2020

n/an/a

n/an/a

n/an/a

n/an/a

n/an/a

2030

2416

n/an/a

Code Description Dimension mm Storage capacity 340 L 500 L 520 L 800 L

13644

13196

Storage racks for upright freezers, for boxes with sizes of 129x129x 75 H mm PLATILAB VERT. IRILAB VERT.

Horizontal without boxes

Horizontal without boxes

W130xD544xH318

W130xD544xH239

Boxes per rackRaks per freezers

Boxes per rackRaks per freezers

n/an/a

1212

n/an/a

1220

1616

n/an/a

n/an/a

1230

Code Description Dimension mm Storage capacity 340 L 500 L 520 L 800 L

Fiberboard boxes for all racks

13838

13839

10 boxes 129x129x50H mm without dividers

10 boxes 129x129x75H mm without dividers

Code Description

13840

13841

13842

Internal dividers for all boxes

25 internal dividers 49 cells, diameter each 15 mm

25 internal dividers 100 cells, diameter each 12 mm

25 internal dividers 81 cells, diameter each 13 mm

Code Description

8

Page 9: Ultralow temperature freezers -86°C Platilab & Irilab Seriessiteadm.angelantoni.it/Media/brc/BRC_0528.pdf · Chest and upright freezers operating at -86°C, designed for long term

Equipment /CRYOLOG data management software

Main features of CRYOLOG

• Acquisition and monitoring of all data parameters• Ethernet communication with programmable TCP/IP address• Creation of a complete data base on computer hard disk• Log storage and display of all events such as alarms, failures, door opening• Fully programmable temperature graphs view (curve,zoom, color, grid selection...)• Possibility of multiple view of different temperature curves by sliding cursor• Reading and decrypting to .csv file, of SD memory card data used by ColdBrain™.

Minimum computer requirements

Before installing the CRYOLOG application, please be sure that your computer includes at least the following equipment:• Intel Pentium 4 processor or higher version• 1 GB RAM• 200MB of free space on the Hard-Disk• 1280 x 720 minimum resolution, 16 million colors• One Ethernet card • Mouse & keyboard• Windows Vista / 7 / 8

To connect any device to the computer where CRYOLOG is installed, two Ethernet cables of proper length and one Ethernet Switch are necessary: one cable is for the device and another one for computer connection.If you have more than one device to connect with CRYOLOG, you need as many Ethernet cables as the number of devices you wish to connect to the computer, plus one extra cable, for the connection between the Switch and the computer.

9

FREEZER n... FREEZER 1

(Ethernet cables)

(Ethernet Switch)

(PC)

CRYOLOGSWR

FREEZER 2 FREEZER 3

Schematic connection of -86° C freezers to computer with CRYOLOG

Page 10: Ultralow temperature freezers -86°C Platilab & Irilab Seriessiteadm.angelantoni.it/Media/brc/BRC_0528.pdf · Chest and upright freezers operating at -86°C, designed for long term

Copyright © 2015 Angelantoni Life Science S.r.l. / Rev. 01 - Illustration, description and technical data may change without notice.

Biomedical refrigerators and freezers (+4°/-86°C), chambers for stability tests and LN2 robotic storage system for vials (-180°C)

Refrigeration systems for industrial processes

Angelantoni Infection Control, steam sterilizers, washers and biohazard waste treatment

Biosafety laminar flow cabinets