Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
PMI MODEL P8T-100M40G-95-T-512-292FF-IND IS A HIGH SPEED, SINGLE POLE, EIGHT THROW, ABSORPTIVE SWITCH THAT OPERATES OVER THE 0.1 TO 40 GHz FREQUENCY
RANGE. THIS MODEL IS DESIGNED TO ACHIEVE OVER 80 dB OF ISOLATION AND SWITCHES IN LESS THAN 100ns ALL IN A SLIMLINE PACKAGE MEASURING ONLY
4.0” X 1.5” X 0.4”.
October 21, 2015Report By: Paul Kuhn, Michael Benjamins
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 1 of 13
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
Table of Contents
1. Product Feature: ·········································································································· Page 3
4. Input/Output Return Loss Vs. Frequency: ·································································· Page 6
2. Summary Data: ··········································································································· Page 4
3. Inserstion Loss Vs. Frequency: ··················································································· Page 5
5. Termination Return Loss Vs. Frequency: ··································································· Page 8
8. Switching Speed: ········································································································ Page 11
6. Page 9
7. Isolation and Insertion Loss at 20dBm Vs. Frequency: ·············································· Page 10
Isolation Vs. Frequency: ·····························································································
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 2 of 13
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
Product Feature
PLANAR MONOLITHICS INDUSTRIES, INC.7311-F GROVE ROAD
FREDERICK, MARYLAND 21704 USA
WEBSITE: [email protected]
ISO 9001 CERTIFIED
TEL: 301-662-5019 FAX: 301-662-1731FREDERICK, MARYLAND 21704 USA
E-MAIL: WEBSITE:
” ” ”
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 3 of 13
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
GHz GHz GHz
-5.8 dB -6.6 dB -9.5 dB (J1-J2)
-4.8 dB -5.7 dB -8.6 dB (J1-J3)
-4.7 dB -5.5 dB -7.7 dB (J1-J4)
-5.3 dB
-5.2 dB -5.6 dB -8.8 dB (J1-J7)
-4.5 dB -6.2 dB -8.7 dB
2 Isolation90 dB MIN (0.1 TO 18 GHz)80 dB MIN (18 TO 40 GHz)
0.1 to 18 18 to 40PORT
GHz GHz
-105.3 dB -101.4 dB (J1-J5)
-105.6 dB
-107.7 dB -103.0 dB (J1-J2)
-105.5 dB -102.7 dB (J1-J3)
-107.0 dB -103.5 dB (J1-J4)
-102.5 dB (J1-J6)
TEST ITEM NO
PARAMETERS SPECIFIED VALUE TEST RESULTS QA QC
Summary Data
1 Frequency Range 0.1 GHz to 40.0 GHz 0.1 GHz to 40.0 GHz
-105.7 dB -103.6 dB (J1-J7)
-108.3 dB -97.8 dB (J1-J8)
-107.7 dB -102.2 dB (J1-J9)
3 Insertion Loss
11 dB MAX6 dB TYP (0.1 TO 18 GHz)
7 dB TYP (18 TO 26.5 GHz)10 dB TYP (26.5 TO 40 GHz)
0.1-18 18-26.5 26.5-40PORT
-5.5 dB -7.9 dB (J1-J5)
-4.3 dB -5.9 dB -9.3 dB (J1-J6)
(J1-J8)
-5.2 dB -6.6 dB -7.6 dB (J1-J9)
4 VSWR 2.5:1 TYP
3.04:1 (J1-J2); 2.72:1 (J1-J3)2.63:1 (J1-J4); 2.77:1 (J1-J5)2.87:1 (J1-J6); 2.80:1 (J1-J7)3.09:1 (J1-J8); 3.09:1 (J1-J9)
5 Operating Input Power +20 dBm CW +20 dBm CW
7 Power Supply+5V @ 500 mA
-12V @ 200 mA+5 @ 202 mA-12 @71 mA
6 Switching Speed 100 ns MAX. 60 ns
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 4 of 13
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
‐6
‐5
‐4
‐3
‐2
‐1
0 2 4 6 8 10 12 14 16 18
Inse
rtio
n Lo
ss (
-dB
)
Frequency (GHz)
Inserstion Loss Vs. Frequency (0.1 to 18 GHz) J1‐J2
J1‐J3
J1‐J4
J1‐J5
J1‐J6
J1‐J7
J1‐J8
J1‐J9
‐8
‐7
‐6
‐5
‐4
‐3
18 19 20 21 22 23 24 25 26
Inse
rtio
n Lo
ss (
-dB
)
Frequency (GHz)
Inserstion Loss Vs. Frequency (18 to 26.5 GHz) J1‐J2
J1‐J3
J1‐J4
J1‐J5
J1‐J6
J1‐J7
J1‐J8
J1‐J9
‐11
‐10
‐9
‐8
‐7
‐6
‐5
‐4
26.5 28 29.5 31 32.5 34 35.5 37 38.5 40
Inse
rtio
n Lo
ss (
-dB
)
Frequency (GHz)
Inserstion Loss Vs. Frequency (26.5 to 40 GHz) J1‐J2
J1‐J3
J1‐J4
J1‐J5
J1‐J6
J1‐J7
J1‐J8
J1‐J9
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 5 of 13
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
‐40
‐35
‐30
‐25
‐20
‐15
‐10
‐5
0
0 2 4 6 8 10 12 14 16 18
Ret
urn
Loss
(-d
B)
Frequency (GHz)
Input Return Loss Vs. Frequency (0.1 to 18 GHz)
J1‐J2
J1‐J3
J1‐J4
J1‐J5
J1‐J6
J1‐J7
J1‐J8
J1‐J9
‐40
‐35
‐30
‐25
‐20
‐15
‐10
‐5
0
0 2 4 6 8 10 12 14 16 18
Ret
urn
Loss
(-d
B)
Frequency (GHz)
Output Return Loss Vs. Frequency (0.1 to 18 GHz)
J1‐J2
J1‐J3
J1‐J4
J1‐J5
J1‐J6
J1‐J7
J1‐J8
J1‐J9
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 6 of 13
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
‐40
‐35
‐30
‐25
‐20
‐15
‐10
‐5
0
18 20 22 24 26 28 30 32 34 36 38 40
Ret
urn
Loss
(-d
B)
Frequency (GHz)
Input Return Loss Vs. Frequency (18 to 40 GHz)
J1‐J2
J1‐J3
J1‐J4
J1‐J5
J1‐J6
J1‐J7
J1‐J8
J1‐J9
‐40
‐35
‐30
‐25
‐20
‐15
‐10
‐5
0
18 20 22 24 26 28 30 32 34 36 38 40
Ret
urn
Loss
(-d
B)
Frequency (GHz)
Output Return Loss Vs. Frequency (18 to 40 GHz)
J1‐J2
J1‐J3
J1‐J4
J1‐J5
J1‐J6
J1‐J7
J1‐J8
J1‐J9
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 7 of 13
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
‐40
‐35
‐30
‐25
‐20
‐15
‐10
‐5
0
18 20 22 24 26 28 30 32 34 36 38 40
Ret
urn
Loss
(-d
B)
Frequency (GHz)
Termination Return Loss Vs. Frequency (18 to 40 GHz)
J1‐J2
J1‐J3
J1‐J4
J1‐J5
J1‐J6
J1‐J7
J1‐J8
J1‐J9
‐40
‐35
‐30
‐25
‐20
‐15
‐10
‐5
0
0 2 4 6 8 10 12 14 16 18
Ret
urn
Loss
(-d
B)
Frequency (GHz)
Termination Return Loss Vs. Frequency (0.1 to 18 GHz)
J1‐J2
J1‐J3
J1‐J4
J1‐J5
J1‐J6
J1‐J7
J1‐J8
J1‐J9
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 8 of 13
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
‐140
‐130
‐120
‐110
‐100
0 2 4 6 8 10 12 14 16 18
Isol
atio
n (-
dB)
Frequency (GHz)
Isolation Vs. Frequency (0.1 to 18 GHz)
J1‐J2
J1‐J3
J1‐J4
J1‐J5
J1‐J6
J1‐J7
J1‐J8
J1‐J9
‐140
‐130
‐120
‐110
‐100
‐90
18 20 22 24 26 28 30 32 34 36 38 40
Isol
atio
n (-
dB)
Frequency (GHz)
Isolation Vs. Frequency (18 to 40 GHz)
J1‐J2
J1‐J3
J1‐J4
J1‐J5
J1‐J6
J1‐J7
J1‐J8
J1‐J9
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 9 of 13
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
‐140
‐130
‐120
‐110
‐100
100 1000
Isol
atio
n (-
dB)
Frequency (MHz Logarithmic Scale)
Isolation Vs. Frequency (0.1 to 6 GHz)
J1‐J2
J1‐J3
J1‐J4
J1‐J5
J1‐J6
J1‐J7
J1‐J8
J1‐J9
‐4
‐3
‐2
‐1
0
100 1000
Inse
rtio
n Lo
ss (
-dB
)
Frequency (MHz Logarithmic Scale)
Inserstion Loss Vs. Frequency (0.1 to 6 GHz @ 20 dBm )
J1‐J2
J1‐J3
J1‐J4
J1‐J5
J1‐J6
J1‐J7
J1‐J8
J1‐J9
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 10 of 13
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
Yellow Trace: Logic Input Pulse
Green Trace: RF Measured with a Crystal Detector
Switching Speed
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 11 of 13
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
Yellow Trace: Logic Input Pulse
Green Trace: RF Measured with a Crystal Detector
Switching Speed
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 12 of 13
Typical CharacteristicsFor
P8T-100M40G-95-T-512-292FF-IND
Yellow Trace: Logic Input Pulse
Green Trace: RF Measured with a Crystal Detector
Switching Speed
7311‐F Grove Road Frederick, MD 21704 USA
Phone: (301)662‐5019 Fax: (301)662‐1731
Website: www.pmi‐rf.com Email: sales@pmi‐rf.com Page 13 of 13