8
Heat Exchanger Technology by Tubular Heat Exchangers Heat Transfer Technology from Bowman BOWMAN ® 100 YEARS OF HEAT TRANSFER TECHNOLOGY

Tubular - EJ Bowman · 2020. 12. 4. · Bowman tubular heat exchangers are intended to be used with a separate header tank (not supplied), which can be positioned remotely from the

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Tubular - EJ Bowman · 2020. 12. 4. · Bowman tubular heat exchangers are intended to be used with a separate header tank (not supplied), which can be positioned remotely from the

Heat Exchanger Technology by

TubularHeat Exchangers

Heat Transfer Technology from Bowman

Fire Protection Systems

BOWMAN®1 0 0 Y E A R S O F H E AT T R A N S F E R T E C H N O L O G Y

Page 2: Tubular - EJ Bowman · 2020. 12. 4. · Bowman tubular heat exchangers are intended to be used with a separate header tank (not supplied), which can be positioned remotely from the

Bowman tubular heat exchangers are designed for cooling engines in applications where air cooling is either unavailable or inappropriate.

For over 50 years, they have been used to cool engine jacket water in applications as diverse as marine propulsion, power generation systems, automotive engine testing and emergency fire protection systems.

Efficient cooling is vital to the performance of an engine and by installing Bowman heat exchangers, the correct operating temperature can be maintained.

Bowman tubular heat exchangers also offer a more compact cooling solution to traditional air blast radiators, aiding engine packaging when space is at a premium.

Staying cool under pressureBowman Tubular Heat ExchangersFor cooling marine and stationary land based engines

2 2

Fully floating tubestackThe ‘fully floating’ design allows for expansion and contraction of the tubestack within the cast body of the heat exchanger, minimising thermal stress, enhancing reliability and longevity. Simple to maintainThe removable end covers enable the tubestack to be easily withdrawn making cleaning and routine maintenance simple. Marine and land based versionsWhether the cooling medium is salt water, fresh water, or mineral rich/contaminated water, Bowman has the most comprehensive range of heat exchangers to suit any marine or land based application. Titanium tube stacksTitanium is the ultimate ‘fit and forget’ material for applications where aggressive water conditions exist. Bowman also offer titanium tube stacks as an option on many of our tubular heat exchangers.

Remote header tankBowman tubular heat exchangers are intended to be used with a separate header tank (not supplied), which can be positioned remotely from the unit in the most convenient location. Easy product selectionAt Bowman, we have developed a computer programme to select the correct heat exchanger for your application. Simply by supplying us with the following information we can advise the correct unit for your requirements;

1: Heat to be dissipated in kW2: Engine coolant flow in l/min3: Max. engine coolant temperature in °C4: Raw water temperature in °C5: Type of raw water to be used (sea, fresh or contaminated)

Page 3: Tubular - EJ Bowman · 2020. 12. 4. · Bowman tubular heat exchangers are intended to be used with a separate header tank (not supplied), which can be positioned remotely from the

Type Typical Engine Suitability

Max Raw Water Flow Raw Water Volume Engine Coolant Volume Equivalent Header Tank Heat Exchanger

kW litre/min litre litreEC80-4276-1 20 54 0.31 0.26 -

EC100-4276-2 40 54 0.44 0.49 EH100-3401-2EC120-4276-3 52 54 0.57 0.74 EH200-3401-3FC100-3891-2 82 95 0.84 1.10 FH100-3182-2FC120-3891-3 115 95 1.06 1.50 FH200-3182-2FG100-3910-2 150 125 1.56 2.40 FH300-3282-2FG120-3910-3 200 125 1.96 3.00 FH400-3282-3GL140-3167-2 240 225 3.10 3.60 GH200-3482-2GL180-3167-3 320 225 3.80 4.80 GH300-3482-3GL240-3167-4 400 225 4.60 6.30 GH400-3482-4GK190-3168-3 450 325 6.30 7.00 KH200-3071-3GK250-3168-4 600 325 7.50 9.00 KH300-3071-4GK320-3168-5 750 325 9.00 11.60 KH400-3071-5JK190-3932-3 620 460 8.80 9.70 JH200-3335-3JK250-3932-4 820 460 10.40 12.50 JH300-3335-4JK320-3932-5 1000 460 12.50 16.10 JH400-3335-5PK250-3170-4 1200 700 16.00 13.60 PH200-3073-4PK320-3170-5 1500 700 21.80 22.60 PH300-3073-5PK400-3170-6 1800 700 25.30 28.50 PH400-3073-6RK400-5883-6 2500 1000 37.90 43.40 -

Marine Tubular Heat Exchangers

This table is intended to provide a general guide to the typical performance of Bowman marine tubular heat exchangers, for engine jacket water cooling and installed in conjunction with a separate header tank.

3

Type Typical Engine Suitability

Max Raw Water Flow Raw Water Volume Engine Coolant Volume Equivalent Header Tank Heat Exchanger

kW litre/min litre litreEC80-1435-1 20 54 0.31 0.26 -

EC100-1435-2 40 54 0.44 0.49 EH100-4065-2EC120-1435-3 52 54 0.57 0.74 EH200-4065-3FC100-1436-2 82 95 0.84 1.10 FH100-4066-2FC120-1436-3 115 95 1.06 1.50 FH200-4066-2FG100-3909-2 150 125 1.56 2.40 FH300-4067-2FG120-3909-3 200 125 1.96 3.00 FH400-4067-3GL140-3166-2 240 225 3.10 3.60 GH200-4068-2GL180-3166-3 320 225 3.80 4.80 GH300-4068-3GL240-3166-4 400 225 4.60 6.30 GH400-4068-4GK190-3487-3 450 325 6.30 7.00 KH200-4069-3GK250-3487-4 600 325 7.50 9.00 KH300-4069-4GK320-3487-5 750 325 9.00 11.60 KH400-4069-5JK190-3931-3 620 460 8.80 9.70 JH200-4070-3JK250-3931-4 820 460 10.40 12.50 JH300-4070-4JK320-3931-5 1000 460 12.50 16.10 JH400-4070-5PK250-1670-4 1200 700 16.00 13.60 PH200-4071-4PK320-1670-5 1500 700 21.80 22.60 PH300-4071-5PK400-1670-6 1800 700 25.30 28.50 PH400-4071-6RK400-5884-6 2500 1000 37.90 43.40 -

Land Based Tubular Heat Exchangers

Page 4: Tubular - EJ Bowman · 2020. 12. 4. · Bowman tubular heat exchangers are intended to be used with a separate header tank (not supplied), which can be positioned remotely from the

24

1 ¼" BSP

1 ¼" BSP

1 ½" BSP 1 ½" BSPEngine CoolantOutlet

Engine CoolantInlet

Raw Water Inlet

Raw Water Outlet

Drain Plug ¼" BSP

Drain Plug ¼" BSP

'B'

mm Ø 821

76 mmM8 x 12mm Deep

'C'

FG

80 m

m70

mm

132 mm'A'

32 m

m 32 m

m

1"

1"

1¼" BSP1¼" Engine Coolant Outlet

Engine Coolant Inlet

Raw Water Inlet

Raw Water Outlet

'B'

mm Ø 801

'C'M8 x 12mm Deep

Drain Plug ¼" BSP

Drain Plug ¼" BSP

76 mm

25 m

m

FC

'A'

25 m

m

68 mm59 mm

67 m

m63

mm

'A'

'C'

55 m

m50

mm

53 mm50 mm

52 mm

3/4" BSP

3/4" BSP

M6 x 10mm Deep

Ø84 mmDrain Plug ¼" BSP

Engine Coolant Outlet

Engine CoolantInlet

Raw Water Inlet

Raw Water Outlet20

mm 20

mm

EC

'B'

'D' 'D'

EC Range

FC Range

FG Range

Maximum working pressure 16 bar. Maximum working temperature 110°C.

Type Weight A B C D

kg mm mm mm BSPEC80 2.4 174 60 60 3/4”

EC100 3.2 260 140 104 1”EC120 3.8 346 226 190 1”

Type Weight A B C

kg mm mm mmFC100 6.3 358 202 190FC120 7.3 456 300 288

Type Weight A B C

kg mm mm mmFG100 10 472 294 190FG120 12 600 422 318

Page 5: Tubular - EJ Bowman · 2020. 12. 4. · Bowman tubular heat exchangers are intended to be used with a separate header tank (not supplied), which can be positioned remotely from the

25

Type Weight A B C D

kg mm mm mm BSPEC80 2.4 174 60 60 3/4”

EC100 3.2 260 140 104 1”EC120 3.8 346 226 190 1”

Type Weight A B C

kg mm mm mmFC100 6.3 358 202 190FC120 7.3 456 300 288

Type Weight A B C

kg mm mm mmFG100 10 472 294 190FG120 12 600 422 318

1 ½" BSP

1 ½" BSP

Engine Coolant Outlet

Engine Coolant Inlet

Raw Water Inlet

Raw Water Outlet

Drain Plug ¼" BSP Drain Plug ¼" BSP

'A'

'C'

mm Ø 261

170 mm

M10 x 15mm Deep 120 mm

GL

38 m

m 38 m

m

100

mm

90 m

m

'B'

42.9

mm

101.8 mm

77.8 mm

R12 mmM12 x 22mm DeepSAE (ISO 6162-1) Nominal Flange Size DN51

Ø51

54 m

m5. 84

mm

GL Range

GK Range

Maximum working pressure 16 bar. Maximum working temperature 110°C.

Type Weight A B C

kg mm mm mmGL140 18 502 272 108GL180 21 630 400 236GL240 25 776 546 382

Type Weight A B C

kg mm mm mmGK190 34 674 370 236GK250 39 820 516 382GK320 46 998 694 560

Type Weight A B C

kg mm mm mmJK190 58 704 340 236JK250 66 850 486 382JK320 78 1028 664 560

2" BSP

2" BSP

Engine CoolantOutlet

Engine CoolantInlet

Raw Water Inlet

Raw Water Outlet

Drain Plug ¼" BSP Drain Plug ½" BSP

'B'

'A'

50 m

m

50 m

m

'C'120 mm

206 mm

SAE (ISO 6162-1) Nominal Flange Size DN64

M12 x 18mm Deep

198Ø mm

GK

120

mm

110

mm

114.9 mm

88.9 mm

50.8

mm

108

mm

R13 mm

Ø64

M12 x 24mm Deep

2 ½" BSP

2 ½" BSP

Engine CoolantOutlet

Engine CoolantInlet

Raw Water Inlet

Raw Water Outlet

Drain Plug ½" BSP

Drain Plug ½" BSP

SAE (ISO 6162-1) Nominal Flange Size DN76'B'

'A'

60 m

m

60 m

m

'C'

232Ø mm

130

mm

140

mm

150 mm

240 mm

92 m

m

92 mmM12 x 24mm DeepM16 x 25mm Deep R14 mm

JK

R20 mm

146

mm

61.9

mm

106.4 mm

146 mm

Ø76

M16 x 30mm Deep

M16 x 30mm DeepEqual-Spaced On A 150mm PCD

(PN6 Equivalent)

120

mm

JK Range

Page 6: Tubular - EJ Bowman · 2020. 12. 4. · Bowman tubular heat exchangers are intended to be used with a separate header tank (not supplied), which can be positioned remotely from the

2 6

Maximum working pressure 16 bar. Maximum working temperature 110°C.

Type Weight A B C

kg mm mm mmPK250 94 900 476 382PK320 110 1078 654 560PK400 125 1280 856 762

Type Weight A B C

kg mm mm mmRK400 186 1392 812 762

Engine CoolantOutlet

Engine CoolantInlet

Raw Water Inlet

Raw Water Outlet

Drain Plug ½" BSPDrain Plug ½" BSP

SAE (ISO 6162-1) Nominal Flange Size DN102

'A'

'B'

'C'M16 x 32mm Deep

220 mm

396 mm

4" Ø18mm Holes On A 180mm PCD

(DN100 PN16 Equivalent)

Ø102

RK

75 m

m Ø220

190 mm

130.2 mm

77.8

mm

190

mm

R20 mm

Ø102

M16 x 32mm Deep

338 mmØ

RK Range

3" BSP

3" BSP

Engine CoolantOutlet

Engine CoollantInlet

Raw Water Inlet

Raw Water Outlet

Drain Plug ½" BSP Drain Plug ½" BSP

SAE (ISO 6162-1) Nominal Flange Size DN89'B'

'C'M16 x 25mm Deep

'A'

106 mm

180 mm

170

mm

155

mm

106

mm

R20 mm

286 mm

M16 x 24mm Deep

PK

70 m

m

70 m

m

Ø278 mm

160

mm

69.9

mm

160 mm

120.7 mm

R20 mm

Ø89

M16 x 32mm Deep

M16 x 32mm DeepEqual-Spaced On A 170mm PCD

(PN6 Equivalent)

146

mm

PK Range

Page 7: Tubular - EJ Bowman · 2020. 12. 4. · Bowman tubular heat exchangers are intended to be used with a separate header tank (not supplied), which can be positioned remotely from the

27

Type Weight A B C

kg mm mm mmPK250 94 900 476 382PK320 110 1078 654 560PK400 125 1280 856 762

Type Weight A B C

kg mm mm mmRK400 186 1392 812 762

Installing the Heat ExchangerThe heat exchanger should be installed horizontally, with the engine coolant connections on top and the raw water outlet uppermost and piped up as shown below, to ensure the elimination of any entrained air.

The header tank volume should be at least 17% of the total volume and have a pressure cap of at least 50 kPa.

Bowman recommend using an ethylene glycol solution for the engine cooling circuit in the concentration advised by the engine manufacturer for the operating conditions. Should you intend using an alternative coolant, please contact our sales team.

Replacement PartsA comprehensive range of replacement parts is available for all Bowman heat exchangers. This includes end covers, ‘’O’’ seals, tube stacks, bodies and end cover fixings. Servicing the UnitBy simply unscrewing the end cover retaining screws, the tubestack can be removed from its outer ‘shell’ for routine cleaning and maintenance. On reassembly, it is recommended that the ‘’O’’ rings are renewed to ensure a reliable, water tight seal. Titanium Tube StacksBowman now offer titanium tube stacks as an option for many of our tubular heat exchangers, providing a ‘fit and forget’ solution for the most demanding applications and benefiting from a 10 year guarantee on all titanium material in contact with cooling water. Contact our technical sales team for more details.

Total Engine Cooling SolutionsBowman can provide a complete solution for cooling both marine and land based stationary engines, including:

Charge Air Coolers (Intercoolers)Suitable for engines rated from 50kW to 1200kW

Engine & Gearbox Oil CoolersSuitable for engines rated from 80kW to 8900kW

Header Tank Heat ExchangersSuitable for engines rated from 40kW to 1800kW

Fuel CoolersSuitable for engines rated up to 180kW

Engine CoolantPump

Heat Exchanger

Engine

Header Tank Vent line

ø8mm

Fill line Ø19mm (EC to FC)Ø25mm (GL to RK)

Raw Water

Engine Coolant

Page 8: Tubular - EJ Bowman · 2020. 12. 4. · Bowman tubular heat exchangers are intended to be used with a separate header tank (not supplied), which can be positioned remotely from the

A world of applications 

EJ Bowman (Birmingham) Ltd Chester Street, Birmingham B6 4AP, UKTel: +44 (0) 121 359 5401 Fax: +44 (0) 121 359 7495 Email: [email protected] www.ej-bowman.com

Bowman heat exchangers can be found cooling engines in some of the most extreme conditions in the world. Frome the searing heat of an Australian summer to the chilling depths of an Artic winter, plus just about everything in between.

Cooling the engine jacket water for irrigation pump sets to ensure the pumps engines run reliably despite high ambient air temperatures.

From sport boats and yachts, to commercial vessels, Bowman heat exchangers have been providing marine cooling solutions for over 50 years.

Bowman heat exchangers are used extensively to control engine temperatures during hot and cold testing for both OEM’s and R&D organisations.

Many ‘mission critical’ fire protection systems rely on Bowman heat exchangers to cool engine pumps in the event of an emergency.

All material contained in this brochure is the intellectual property of EJ Bowman (Birmingham) Ltd. It is protected under copyright and may not be reproduced without the prior written consent of the company. EJ Bowman (Birmingham) Ltd, reserve the right to change specifications without prior notice. A

Irrigation Systems Marine Engineering Engine Testing Fire Protection Systems

FM38224

Bowman is now established as the ‘leading brand’ for tubular heat exchangers. With tens of thousands of units operating reliably and efficiently throughout the world, you can have complete confidence when you specify Bowman tubular heat exchangers.

BOWMAN®1 0 0 Y E A R S O F H E AT T R A N S F E R T E C H N O L O G Y