Heaters & Accessories Effective 7-1-13 ** May be used on the LS and LD Series. UPS packages are charged dimensional, not physical weight. New item or price, from prior accessory guide, or heater price sheet. An item that has further technical information available, ex.: spec sheet, instructions, etc. Part No. in BOLD Underlined Item Items in [****] DRP product coding. For internal use only. Tube Heater Packing List Replacement parts information is available online at www.detroitradiant.com/parts and in the product manual. TABLE OF CONTENTS Pricing Guide ........................................................... 2 Low Intensity Tube Heaters ..................................... 3 Available Models ...................................................... 3 Add-On/Upgrade Items .........................................4-5 Extensions, Hardware & Air Items ........................... 6 Misc. Hardware & Other Accessories ...................... 7 Stainless Steel Accys., Add-ons & Upgrades ............. 8 Elec. Components and Misc. Controls ..................... 9 Copyright 2013, Detroit Radiant Products Company LPKTH-1M-9/13 (CDS) The key symbols below and found within designate the following: All orders are subject to acceptance by Detroit Radiant Products Company, Warren, Michigan at prices in effect at date of shipment. All prices are F.O.B. Warren, Michigan. All State, Federal, or Municipal taxes in effect at the time of shipment or imposed at any future time on our products shall be the responsibility of the customer. We reserve the right to change specifications on our products without prior notice to the customer. Shipping Weight Notation: Shipping weight is shown for each item. The per item weight will typically be less when packaging multiple items on one order. Note: Add-ons must be ordered as a separate line item and tagged to the appropriate heater. NOTE: All items shown in this booklet are part of our “TBAC” price code category. SYMBOL DESCRIPTION 21400 Hoover Road, Warren, Michigan 48089 Phone: 586-756-0950 • Fax: 586-756-2626 www.detroitradiant.com • [email protected] Gas-Fired, Low Intensity, Infrared Tube Heaters Single Stage Controls ............................................ 10 Two-Stage Controls ............................................... 11 Advanced Control Options ..................................... 12 MP Series Control Options .................................... 12 3” Venting Accessories ........................................... 13 4” Venting Accessories ........................................... 14 6” & 8” Common Vent Material ............................... 15 Burner Box & Tube Packages ................................ 16

Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

  • Upload
    lydiep

  • View
    221

  • Download
    3

Embed Size (px)

Citation preview

Page 1: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

Heaters & AccessoriesEffective 7-1-13

** May be used on the LS and LD Series.

UPS packages are charged dimensional, not physical weight.

New item or price, from prior accessory guide, or heater price sheet.

An item that has further technical information available, ex.: spec sheet, instructions, etc.Part No. in BOLD

Underlined Item

Items in [****] DRP product coding. For internal use only.

Tube HeaterPacking List

Replacement parts information is available online at www.detroitradiant.com/parts and in the product manual.

TABLE OF CONTENTS

Pricing Guide ...........................................................2

Low Intensity Tube Heaters .....................................3

Available Models ......................................................3

Add-On/Upgrade Items .........................................4-5

Extensions, Hardware & Air Items ...........................6

Misc. Hardware & Other Accessories ......................7

Stainless Steel Accys., Add-ons & Upgrades .............8

Elec. Components and Misc. Controls .....................9

Copyright 2013, Detroit Radiant Products Company LPKTH-1M-9/13 (CDS)

The key symbols below and found within designate the following:

All orders are subject to acceptance by Detroit Radiant Products Company, Warren, Michigan at prices in effect at date of shipment. All prices are F.O.B. Warren, Michigan. All State, Federal, or Municipal taxes in effect at the time of shipment or imposed at any future time on our products shall be the responsibility of the customer. We reserve the right to change specifications on our products without prior notice to the customer.

Shipping Weight Notation: Shipping weight is shown for each item.The per item weight will typically be less when packaging multiple items on one order.Note: Add-ons must be ordered as a separate line item and tagged to the appropriate heater.

NOTE: All items shown in this booklet are part of our “TBAC” price code category.

SYMBOL DESCRIPTION

21400 Hoover Road, Warren, Michigan 48089Phone: 586-756-0950 • Fax: 586-756-2626

www.detroitradiant.com • [email protected]

Gas-Fired, Low Intensity, Infrared Tube Heaters

Single Stage Controls ............................................10

Two-Stage Controls ...............................................11

Advanced Control Options .....................................12

MP Series Control Options ....................................12

3” Venting Accessories ...........................................13

4” Venting Accessories ...........................................14

6” & 8” Common Vent Material ...............................15

Burner Box & Tube Packages ................................16

Page 2: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

HELPFuL STEPS WHEN SELECTING LOW INTENSITY TuBE HEATERS

Step 1: Heater Selection (Pages 3-5)Refer to the chart on Page 3 for available model heaters based on series, tube length, BTU and gas type. Gas type MUST be indicated on all orders. The Available Models chart denotes each heater model column with a letter (A) or (T) which indicates the combustion chamber tube material for that model. (A) indicates an aluminized combustion tube and (T) indicates a titanium stabilized combustion tube. NOTE: This does not apply for stainless steel model heaters. Be sure to use the correct tube heater price based on this (A) and (T) notation.

Step 2: Accessory Selection (Pages 6-8)Chain sets (P/N: THCS) or gripple cables (P/N: THGH10) are typically necessary for hanging each heater (refer to page 7 for required quantities). Additional accessories such as 90° elbows, “U” fittings, protective guards, side shields and decorative grills may be used. There are also options to upgrade certain features to stainless steel. Refer to the descriptions of each accessory for further details.

Step 3: Controls Selection (Pages 9-12)Single-stage, two-stage, advanced controls and modulating controls are available. When heaters are common vented or common intake, they MUST be controlled by the same thermostat.

Single-stage heaters are built standard for 120V controls but have options for 24V controls. The most common option is the use of one relay transformer (P/N: R8285B) per 24V thermostat as there are no heater modifications necessary with this option. Another option is to specify the 24-volt add-on (P/N: 24VAO) per heater at time of ordering. An external transformer (P/N: 4000-01V) is also needed per thermostat with this option.

Two-stage heaters are built standard for 24V controls. When using a single heater to a single thermostat on the HL3 Series and the LD Series models, there is no need for additional components because the internal 24V of the heater can power the thermostat. When installing more than one heater onto the same thermostat, one HLRP(B) relay add-on is necessary per heater. NOTE: DET3 Series models come standard with this relay on all units. Scenarios that have the relays installed will also need one external transformer (P/N: 4000-01V) per thermostat. If the relay add-ons are forgotten or not known at the time of order, there are external panels (refer to page 11) that can be purchased that will allow for multiple heaters to be controlled by the same 24V thermostat.

Modulating heaters have control options for specific needs. Refer to the MP controls section and consult the factory if further support is needed.

Step 4: Venting Selection (Pages 13-15)Sidewall or rooftop venting accessories include 3”, 4”, 6” or 8” options. Basic applications should include a sidewall vent kit or a rooftop vent kit. When common venting two or more heaters together refer to the dual vent material options.

Step 5: Extended Warranties (Page 16)All limited warranties are defined in the product insert manual for the particular series of heaters. We have additional extended warranties available on page 16. Please note, extended warranties cover manufacture defects. If you have special circumstances when bidding a job, please contact the factory for pricing support.

Refer to the chart on Pages 4 for the available add-on/upgrade items and what comes standard with the series heater. The main components that are included with each tube heater contain items such as flex connector, burner box, tubes, reflectors, clamps, end caps, hangers, center supports*, and baffles.

*Only one (1) reflector center support is supplied with economy models.

Reflector(s)

Reflector Center Support*Combustion Chamber(s)

Baffle(s)

Reflector End Caps w/ Clips

Tube Clamp

Burner Control Box

Flexible Gas Connector

Radiant Tube(s)

16” Burner Tube

Tube Hanger

Page 3: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

3

LOW INTENSITY TuBE HEATER QuANTITIES

AVAILABLE MODELS

MO

DE

L

FT-

BT

u-G

AS

10-2

5 N

or

P*

10-3

0 N

or

P*

15-4

0 N

or

P*

15-5

0 N

or

P20

-40

N o

r P

*20

-50

N o

r P

20-6

0 N

or

P20

-65

N o

r P

20-7

5 N

or

P25

-80

N o

r P

30-5

0 N

or

P*

30-6

0 N

or

P30

-65

N o

r P

30-7

5 N

or

P30

-80

N o

r P

30-1

00 N

or

P30

-115

N o

r P

30-1

25 N

or

P40

-50

N o

r P

40-6

0 N

or

P40

-65

N o

r P

40-7

5 N

or

P40

-80

N o

r P

40-1

00 N

or

P40

-115

N o

r P

40-1

25 N

or

P40

-150

N o

r P

40-1

75 N

or

P50

-75

N o

r P

50-8

0 N

or

P50

-100

N o

r P

50-1

15 N

or

P50

-125

N o

r P

50-1

50 N

or

P50

-175

N o

r P

50-2

00 N

or

P60

-125

N o

r P

60-1

50 N

or

P60

-175

N o

r P

60-2

00 N

or

P70

-175

N o

r P

70-2

00 N

or

P80

-200

N o

r P

Comb. Tube A A A A A A A A A A A A A A A A A A A A A A A A A A T T A A A A A T T T A T T T T T T

MP • • • • • • • • • • • •HL3 • • O • • • O • • • • • • • • • • • • • •DX3 • • • O O • • • O O • • • • • • • • • • • • • • • • •DET3 • • • • • • • • • • • • • • • • •DES3 • • • • • • • • • • • • • • • • • • • • • •HL-SS^ • • • • • • • • • •DX-SS^ • • • • • • • • • • • •LD • • • • •LS • • • • • • •SV • • • O O • • • O O • • • • • • • • • • • • • • • •

SERIES 20 FT. 30 FT. 40 FT. 50 FT. 60 FT.

HL-SS

DX-SS

Stainless Steel Commercial & Industrial Heaters

SERIES 20 FT. 25 FT. 30 FT. 40 FT. (A) 40 FT. (T) 50 FT. (A) 50 FT. (T) 60 FT. 70 FT. 80 FT.

MP N/A N/A

HL3 N/A N/A

DX3 N/A

DET3^ N/A N/A N/A

DES3 N/A N/A N/A

Commercial & Industrial Heaters - Series 3

SERIES 10 FT. 15 FT. 20 FT. 30 FT.

LD

LS

Low BTu/Select Residential Heaters

SERIES 20 FT. 30 FT. 40 FT. (A) 40 FT. (T) 50 FT. (A) 50 FT. (T) 60 FT. 70 FT. 80 FT.

SV

unitary Vacuum Heaters

^ Model requires a 24V external transformer.NOTE: See Available Models chart below for combustion chamber tube construction. (A) Aluminized or (T) Titanium.

LENGTH 10 FT. 15 FT. 20 FT. 25 FT. 30 FT. 40 FT. 50 FT. 60 FT. 70 FT. 80 FT.SHIP WT. 85# 100# 120# 145# 160# 190# 235# 265# 300# 330#

SS WT. N/A N/A 145# 180# 195# 235# 290# 330# N/A N/A

BOXING B, S B, S B, S B, L B, L B, L B, L, S B, L, S B, L, L B, L, L

Weights and Boxing Information

* Denotes CSA Residentially Certified LD and LS Series heaters.

O Denotes models with available special use performance test data. Contact factory.^ Denotes Series 2 design only.

Page 4: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

4

TECHNICAL NOTES: For DX-SS or HL-SS models, the minimum BTU’s is 75,000; maximum is 150,000.

Consult charts for all available lengths, BTU’s and options.

SSTAO, SSTRAO and -SS options are not available on 30-125 or 40-175 models.

IMPORTANT: Specify add-on item at time of order. Be sure to tag appropriate heater for add-on.

NOTE: Add-ons will change stocking availability.

OPTIONS KEY

O Option Available.

N Option Not Available.

S Standard Feature.

X Available in BTU Range of 75,000-150,000 Only.

1 Available for Exhauster Pump Only.

BOXING KEY

B1 V2 Burner (45# - 36”L x 24”W x 9”H)

B2 V3 Burner (47# - 37.5”L x 23”W x 12”H)

L Large Tube (122”L x 17.5”W x 15”H)

S Small Tube (122”L x 17.5”W x 10”H)

The SV Series includes an additional box for the exhauster assembly.

AVAILABLE ADD-ON/uPGRADE OPTIONS

MODEL SERIES S

ILS

EA

L

OD

-KIT

IND

-LT

PC

-60

24VA

O

HLR

B/H

LRP

5EA

-Su

B

ALu

M-A

O

L u-A

O

SS

CB

AO

SS

TAO

SS

TAO

-5

SS

RA

O

SS

RA

O-5

SS

TRA

O

SS

TRA

O-5

SS

FWA

O

SS

C-#

#

SS

B-#

#

SS

E-S

S

CW

O/M

PC

WO

EW

O

VP

WO

FC-2

4 “F

lex”

FC-2

4PV

C-A

O

“Fle

x”FC

-36-

AO

“F

lex”

GC

-50

“Val

ve”

MP O O S S N N O S N N X X O O X X O O O O O O N N N S N

HL3 O O S S N O O S N N X X O O X X O O O O O O N S O O O

DX3 O O S S O N O S N N X X O O X X O O O O O O N S O O O

DET3 O N S S N S O O N N N N O O N N N O O O O O N S O O O

DES3 O N O S N N O O N N N N O O N N N O O O O O N S O O O

HL-SS S O S S N O O N N S S S S S S S S S S O O N N S O N S

DX-SS S O S S O N O N N S S S S S S S S S S O O N N S O N S

LD O O S S N O O S O O N N O O N N O N N O O O N S O N S

LS O O S S O N O S O O N N O O N N N N N O O O N S O N S

HLV O N S S N S N N N N X X O O X X N O O O O O O S O O S

SV O N S O1 N N O S N N X X O O X X N N N O O O N S O O S

Page 5: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

5

LS & LD SERIES SPECIFIC ADD-ON/ uPGRADE ITEMS

COMMON ADD-ON / uPGRADE ITEMS

PART NO. DESCRIPTION QTY.

[ACTB]

**SILSEAL

Silicone seal the inside of a control box of any low intensity tube heater. Done at the time of production, this seal will protect the internal components against contaminants that might otherwise penetrate the box. SILSEAL is ideal for high moisture areas such as a car wash. It is standard on all stainless steel heaters.

[ACTB]

PC-60

Three prong, 60 inch power cord set. Can be added to the SV, HL2, or DX2 . Allows heaters to be plugged into a 120V grounded outlet. This is an add-on option only.

[ACTB]

OD-KIT

Outdoor approval kit for HL3, DX3, LS and LD Series. For use when applying heaters outdoor. Includes: PC-60 and 24V control cord (when applicable), SILSEAL, 90° air inlet collar and with outdoor rating label.

[ACTB]

FC-24PVC-AO

Upgrades standard FC-24 (24”) flexible gas connector to a 24” PVC coated flexible gas connector.

[ACTB]

FC-36-AOUpgrades FC-24 (24”) flex connector to a FC-36 (36”) flexible gas connector.

[ACTB]

IND-LT

Indicator lights for DES3 Series heaters. First light indicates burner and differential switch operation. Second light indicates valve operation. Maximum one IND-LT set per heater.

[ACTB]

HLRB

Optional internal relay for LD Series heaters. See page 11 for details. (TP-825) - for replacement parts ordering.

[ACTB]

HLRP

Optional internal dual relays for HL3 Series heaters. See page 11 for details. (TP-1325) - for replacement parts ordering.

PART NO. DESCRIPTION QTY.

For 3” Models [ACTB]

DB-5EA-SUB

Upgrades (1) 10’ piece of radiant tubing & reflector with (2) 5’ pieces. (1) clamp and (1) hanger included. This is ideal for making “U” heaters from 30’, 50’ & 70’ models. Maximum one 5EA-SUB per heater. Add-on option only. Call for availability for 10’ models.

For 4” Models [ACTB]

5EA-SUB

[ACTB]

ALUM-AO

Upgrade hot rolled steel radiant tubes to black coated 16ga. aluminized steel for maximum efficiency and longevity. Highly recommended in any contaminated or moisture laden environment. See below for quantities. 4” diameter only.

Required ALUM-AO per Heater*

MODEL 10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’

STRAIGHT N/A 1 2 3* 4* 5* N/A N/A

[ACTB]

24VAO

24V controls for DX3 and LS Series. Field supply 24V to control heater operation (one 24VAO req. per heater). Allows wiring onto separate circuits. Includes internal relay, power cord, indicator lights and terminal block. External transformer (40VA) required.

[ACTB]

SHAO

Substitute one standard tube hanger with one seismic hanger when seismic suspension is required. See min. quantities below. *Additional TP-19F hangers may be required based on the installation. Refer to Seismic Bracing Installation Instructions (LSH105) for further details.

Required SHAO per Heater

MODEL 10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’

STRAIGHT 2 3 4 5 6 7 8 9

w/ TF1B or E6 1 1 1 1 1 1 1 1

Add’l TP-19F* 0 1 2 3 4 5 6 7

NOTE: Refer to chart on page 4 for add-on & upgrade option availability. availability. See page 8 for stainless steel accessories.

*150,000-200,000 Btu/h models require one less ALUM-AO.

PART NO. DESCRIPTION QTY.

[ACTB]

**LU10-AO

U-bend conversion kit for 10-ft LD/LS Series straight tube heater. Includes DB-5EASUB, DB-RUP and related accessories.

NOTE: For 25,000 and 30,000 BTU ONLY. Overall assembly dimension of 8-ft. 1-in. 10 lbs.

per add-on

[ACTB]

**LU15-AO

U-bend conversion kit for 15-ft LD/LS Series straight tube heater. Includes DB-5EASUB (@7.5-ft. each), DB-RUP and related accessories.

NOTE: For 40,000 BTU ONLY. Overall assembly dimension of 10-ft. 7-in. 10 lbs.

per add-on

PART NO. DESCRIPTION QTY.

[ACTB]

**LU20-AO

U-bend conversion kit for 20-ft LD/LS Series straight tube heater. Includes DB-RUP and related accessories.

NOTE: For all 20-ft models. Overall assembly dimension of 13-ft. 1-in. 10 lbs.

per add-on

[ACTB]

**LU30-AO

U-bend conversion kit for 30-ft LD/LS Series straight tube heater. Includes DB-5EASUB, DB-RUP and related accessories.

NOTE: For all 30-ft models. Overall assembly dimension of 17-ft. 9-in. 10 lbs.

per add-on

LU15-AO and LU30-AO packages are add-on only options at time of production. Note approved BTU’s only. Note heater dimensions with added kit. Note packaging changes (3 cartons total and 10 added pounds) will apply. Follow instruction sheet for assembly requirements.

Page 6: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

6

EXTENSION ACCESSORIES

MISCELLANEOuS HARDWARE ACCESSORIES

AIR COMPONENTS

PART NO. DESCRIPTION QTY.Box ID [AA]

[ACTP]

10EA

Ten foot heater extension assembly includes ten foot, 4” diameter, 16 gauge, aluminized steel tube with high temperature black coating, ten foot reflector, 4” reflector center support, 4” tube clamp and one 4” hanger. This extension must be shipped via truck line. 35 lbs.

Box ID [AB][ACTP]

20EA2) 10EAs in one small box.

70 lbs.Box ID [AC]

[ACTP]

30EA3) 10EAs in one large box.

110 lbs.Box ID [AD]

[ACTP]

40EA

4) 10EAs in one large box.§LPQ Discount of 10%, min. qty. 5

145 lbs.Box ID [AM]

[ACTP]

TR60

Five foot heater extension assembly. See 10 EA for contents and specs. Item can be shipped via UPS. 20 lbs.

PART NO. DESCRIPTION QTY.Box ID [AE]

[ACTP]

10HRE

Ten foot heater extension assembly includes ten foot, 4” diameter, 16 gauge, hot rolled steel tube with blackened appearance, ten foot reflector, 4” tube clamp and one 4” hanger. No RCS center support is included. This extension must be shipped via truck line. 35 lbs.

Box ID [AF][ACTP]

20HRE2) 10HREs in one small box.

70 lbs.Box ID [AG]

[ACTP]

30HRE3) 10HREs in one large box.

110 lbs.Box ID [AH]

[ACTP]

40HRE

4) 10HREs in one large box.§LPQ Discount of 10%, min. qty. 5

145 lbs.Box ID [BD]

[ACTP]

HRE-60

Five foot heater extension assembly. See 10 HRE for contents and specs. Item can be shipped via UPS. 20 lbs.

[ACTB]

E6

Elbow - 6” radius, 90° bend, 4” diameter 16 gauge aluminized steel with black coating, one tube clamp, one hanger, and two reflector end caps with 8 clips. Consult IOM for minimum distance from burner. Sq. dimension 15” x 15.”

8 lbs.

[ACTB]†,**RE

Reflector Elbow - 90° bend, with polished, one side bright reflector elbow. Designed to fit atop one elbow (not included). Sq. dimension 27” x 27.” Field assembly required.

5 lbs.

[ACTB]† REP

Reflector and elbow package - One RE and one E6. Consult IOM for minimum distance to burner. No end caps or clips included. 10 lbs.

[ACCM]†,**PHS

Protective Heat Shield. For use on 0° mounted reflectors only. 30” x 12” 304 grade stainless steel. For attachment below reflector in heat sensitive areas. Includes 2 stainless steel endcaps, 8 clips, 4) 5” bolts and 4 wing nuts. 6 lbs.

[ACTB]

**SSE

62” long x 10-1/2” wide. Side shield extension polished one side bright, used to direct infrared rays downward - away from sidewalls and combustibles with two 0° mounting brackets, 8 screws and 1 RCS. NOTE: DET3 and DES3 models require the purchase of one extra 4” R.C.S (TP-82). NOTE: Two (2) SSE required to span each 10-ft reflector section. Maintain published clearances when using this accessory.

8 lbs.

[ACTB]

TF1B

180° bend (U) shaped fitting, used to make a U shaped configuration. 16 gauge aluminized steel, 4” dia. fitting, with high temperature black coating. Also included: 1 tube clamp, 1 wire hanger, 2 reflector endcaps, and 8 clips. Adds 14” to overall unit length, center to center 16”. Consult IOM for minimum distance from burner. 13 lbs.

[ACTB]

**Ru

Reflector “U” to cover a TF1B “U” fitting (not included). 180° bend “U” reflector for attachment to standard reflectors covering the end of a “U” configuration. Polished, one side bright aluminum. Reflectors cannot be rotated after installation of this accessory. Field assembly required. 5 lbs.

[ACTB]† RUP

Reflector and “U” bend package - One TF1B and one RU. Consult IOM for minimum distance to burner. 14 lbs.

[ACTB]

45E

45° elbow assembly 4-1/2” radius, 16 gauge aluminized steel with high temperature black coating. 4” diameter, one tube clamp, one hanger, 2 end caps with 8 clips. Consult IOM for minimum distance from burner. 7 lbs.

[ACTB]

**SMB

Single mount bracket for use on U-shaped configured heaters. Bracket allows installation from one suspension point, as opposed to two. Bracket also assures uniform spacing between opposing tubes. See chart below for quantity needed. Included: (1) THCS chain set and (5) S-Hooks. NOTE: Two (2) THCS required to mount burner control box. 2 lbs.

REQuIRED SINGLE MOuNT BRACKET (SMB) PER HEATERModel Length 10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’w/TF1B N/A 2 3* 3 4* 4 5* 5* Model requires 5EA-SUB accessory package when installing in a U-shaped configuration.

[ACTB]

**WIV-4

Wall inlet cap, 4” O.D. with bird screen. For use with outside air option. Bird screen insures open air flow to unit. Used for 0-20’ of 4” intake. 3 lbs.

[ACTB]

**WIV-55” version of WIV-4. For use with air intake lengths of 20-30 ft. 3 lbs.

[ACTB]

**WIV-66” version of WIV-4. For use with air intake lengths of 30-40 ft. 3 lbs.

[ACTB]

**RTV-106

Tube of high temperature sealant. Capable of withstanding temperatures up to 500°F. Commonly used for sealing venting, combustion air inlet, and burner boxes. Meets NFPA - 54 requirements. 1 lbs.

[ACTB]

**TEE-4

4” DWV (Drain Waste Vent) tee with screened intakes. Mates to field supplied 4” DWV pipe for use in providing outside combustion air to heater. Air openings provide dual sources of combustion intake air. 2 lbs.

[ACTB]

**AIRH

4” flexible air inlet rubber hose with DWV adapter affixed. Mates to 4” DWV pipe. Clear color for visibility. Includes 4” DWV adapter and worm clamp. 18” in length. 2 lbs.

[ACTB]

**AK-T4

Agricultural air intake kit consisting of AIRH and TEE-4. Field supply 4” DWV pipe (18 in.-20 ft.) to complete assembly.

3 lbs.

Page 7: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

7

PART NO. DESCRIPTION QTY.

[ACTB]

**THGH10

Gripple tube heater hanging cables. 10 foot length of looped cable with a locking fastener per assembly. Working load limit of 100 lbs with a 5:1 load safety ratio.

1 lb.

[ACTB]

**THGH20

Gripple tube heater hanging cables. 20 foot length of looped cable with a locking fastener per assembly. Working load limit of 100 lbs with a 5:1 load safety ratio. 2 lbs.

[ACTB]

**THCS

Five foot chain set with 2 “S” hooks used for hanging heater. Bulldog coil chain, trade size #1, wire gauge 12, and a working load limit of 155 lbs. each.

[ACTB]

**RVA-CS

8” Chain mounting set with 2 – “S” hooks, 1 – chain, and 1 – 3” open eye screw to secure to structure. 12” structure spacing. 1 lb.

REQuIRED CHAIN OR CABLE SETS PER HEATER (FOR 10’ CENTERS) Model Length 10’ 15-20’ 25-30’ 35-40’ 45-50’ 55-60’ 65-70’ 80’

STRAIGHT* 4 5 6 7 8 9 10 11

w/TF1B N/A 6 8 8 10 10 12 12[ACCM]

**S-HOOK*Straight refers to models in a straight configuration (10’ centers). THCS for HLV series: Three (3) per burner box; one (1) for each 10ft. tube section.

[ACTB]

**BK

“Brass Knuckles.” Reflector mounting bracket that allows for mounting the reflector on specified angles. Attaches to TP-19B wire hanger. Preset bends allow for a 15, 30, or 45 degree mounting angle. See chart below for quantity needed. BK attaches to standard hangers. 1 lb.

REQuIRED BK FITTINGS PER HEATER Model Length 10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’STRAIGHT* 2 3 4 5 6 7 8 9

w/TF1B 3 4 5 6 7 8 9 10

[ACTB]

**BRDG

Decorative Grill designed to encase radiant tubes. Attaches to reflector - use side clearance data. Mounts at 0-45 degrees. Finished in a highly polished aluminum casing and eggcrate bottom surface. 60” x 18” x 4.5”. Field assembly required. Use DCSP chart for quantity required. Not for ‘U’ tubes. 8 lbs.

MISCELLANEOuS HARDWARE ACCESSORIES

PART NO. DESCRIPTION QTY.

[ACTB]

**PG

Protective guard. Designed to attach to standard reflector. 5’ long x 13-1/4” wide with 1-1/4” slots. Galvanized wire with slip-on style mounting channels. 2 restraining cables and 1 reflector center support included.

Typically used to prevent debris or objects from becoming lodged between radiant tube and reflector. Must be used when mounting heaters below 8 ft.

7 lbs.REQuIRED GuARDS PER HEATER

Model Length 10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’

STRAIGHT* 2 4 6 8 10 12 14 16

w/TF1B N/A 4 6 8 10 12 14 16

*Straight refers to models in a straight configuration. PG for HLV series: Two (2) for each 10 ft. tube section.

[ACTB]†,**DCSP

Drop ceiling side panels. Polished one side bright. Used to direct infrared rays away from ceiling tiles. 62” in length, mounts with 2 zip screws to the heaters reflector. Shipped in sets of 2 pieces.

6 lbs.REQuIRED DCSP PER HEATER (SETS)

Model Length 10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’STRAIGHT 2 4 6 8 10 12 14 16

[ACTB]†,**EC

Aluminum Egg Crate - 24” x 48”. Designed to fit into a standard 2’ x 4’ ceiling tile opening. Crate has 1/2” x 1/2” openings and is 1/2” thick. Mounts 1-1/2” below the bottom of the tube. See chart below for quantity needed. Used in conjunction with DCSP (see above).

8 lbs.REQuIRED ALuMINuM EGG CRATES PER HEATER

Model Length 10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’

STRAIGHT 3 6 9 12 15 18 21 24

[ACCM]

**FC-24

24 in. (1/2” I.D.) stainless steel flex connector with brass fittings. Not for use with gas pressure in excess of 1/2 PSI. Both fittings are 1/2 in. pipe thread by 1/2 in. flare thread. In most parts of the country, the use of flexible connectors requires units to be rigidly mounted. Consult local codes for compliance. a.k.a. TP-83. 2 lbs.

[ACCM]

**FC-24PVC

See FC-24. Coated with P.V.C. a.k.a. TP-83A.

2 lbs.

[ACCM]

**FC-36

36 in. stainless steel flexible (3/4” I.D.) connector with brass fittings. Not for use with gas pressures in excess of 1/2 PSI. Both fittings are 3/4” pipe thread by 1/2” flare thread. NOTE: 1/2” x 3/4” reducer required to connect to heater (field supplied). For use with all MP Series heaters and recommended for use with other 175,000 & 200,000 BTU/H model tube heaters. Consult local codes for compliance. 1 lb.

[ACCM]

HKAP-33

Aluminum cleaner, brightener and conditioner. Concentrated solution penetrates deep into the pores of the aluminum and lifts or dissolves oxidation, soils and other surface contaminants. 32 ounces.

1 lb.

OTHER ACCESSORIES

[ACCM]

**325-3

Maxitrol high pressure regulator, 2 PSI maximum inlet pressure on natural and propane gas. 12” W.C.P. outlet pressure setting, 1/2” x 1/2” NPT, 150,000 BTU/H flow capacity. CSA Design Certified and meets NFPA-54 requirements for vent limiting devices. 2 lbs.

[ACCM]

**325-5

Maxitrol regulator (see 325-3 above) with 300,000 BTU/H flow capacity. 3/4” x 3/4” NPT. CSA Design Certified and meets NFPA-54 requirements for vent limiting devices. 2 lbs.

[ACCM]

**325-3 OPD

Maxitrol regulator 1/2” x 1/2” NPT with vent limiting device. 2-5 PSI maximum inlet pressure on natural gas only. Meets ANSI Z21.80 Standard for line regulators. 3 lbs.

[ACCM]

**GC-50

CSA Design Certified ball valve, 2 PSI maximum pressure, 1/2” x 1/2” FPT, with 1/8” NPT side pressure tap. 1 lb.

[ACCM]

**PLQ

Clearance Safety Limit Sign. 24 gauge aluminum 10” x 7”. Sign is designed to be hung or adhered at clearance to combustibles limit. Repeats clearance warnings. 1 lb.

[ACTB]

**TSP-S

Small spray can (3 ounces) of black touch-up, high temperature paint. For use on black coated tubes. 1 lb.

[ACTB]

**TSP-LLarge spray can (12 ounces) of black touch-up, high temperature paint. 1 lb.

Page 8: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

8

STAINLESS STEEL ACCESSORIES

PART NO. DESCRIPTION QTY.

[PTTB]

TP-26D

304 grade stainless steel radiant tube. 16 gauge, 4 in. x 10 ft., high temperature black coated. 37 lbs.

[PTTB]

TP-26E

409 grade stainless steel combustion tube. 16 gauge, 4 in. x 10 ft., high temperature black coated. 37 lbs.

[ACTB]

SSR

120 in. 304 grade, polished stainless steel reflector. Includes (2) stainless steel end caps with (8) clips. 22 lbs.

[ACTP]

SST-60

60 in. 304 grade stainless steel tube. 16 gauge, stainless steel. High temperature black coated. Includes (1) hanger with (1) stainless steel butt clamp.

24 lbs.

[ACTB]

TF1B-SS

4 in. 304 grade stainless steel 180° U-shaped fitting. See TF1B on page 6. Includes (1) stainless steel clamp, (1) TP-19B hanger, and (2) stainless steel reflector end caps with clips.

13 lbs.

[ACTB]

THCS-SS

30 in. stainless steel chain set with two “S” hooks. Suitable for hanging heater in tight applications such as car washes. See THCS on page 7 for quantity required per heater. 1 lb.

PART NO. DESCRIPTION QTY.

[ACTB]

RE-SS

304 grade stainless steel reflector elbow 90° bend to cover an elbow (E6) fitting (not included). Field assembly required. 27 in. x 27 in. square. 9 lbs.

[ACTB]

Ru-SS

304 grade stainless steel reflector “U” to cover a TF1B “U” fitting (not included). Field assembly required. 27 in. x 27 in. square. 12 lbs.

[ACTB]

SSR-60

60 in. 304 grade, polished stainless steel reflector. Includes (2) stainless steel end caps with (8) clips. 12 lbs.

[ACTB]

E6-SS

304 grade stainless steel elbow. 6” radius, 90° bend, 4” diameter, 16 gauge stainless steel with black coating. Includes (1) stainless steel tube clamp, (1) stainless steel hanger and (2) stainless steel reflector end caps with 8 clips. 8 lbs.

[ACTB]

SSE-SS

304 grade stainless steel side shield extension. Used to direct infrared rays downward away from sidewalls and combustibles with (2) 0° mounting brackets, (8) screws and (1) RCS. 62 in. long x 10.5 in. wide. NOTE: DES3 models require an additional RCS (TP-82) not included. 14 lbs.

[ACTB]

BK-SS

Stainless steel “Brass Knuckles.” Reflector mounting bracket attaches to wire hanger allowing the reflector to be mounted on a 15, 30 or 45 angle. See BK on page 7 for quantity required per heater. 1 lb.

STAINLESS STEEL ADD-ON OPTIONS & uPGRADES

PART NO. DESCRIPTION QTY.

[ACTB]

SSTAO

Stainless steel tube add-on upgrades existing tube exchangers from titanium/aluminized to 304 grade stainless steel tubes. Tube clamp is stainless steel. NOTE: Combustion chamber is 409 grade stainless. MP, HL3, DX3 only. One needed per 10 ft. of tube. Sold as an add-on to an order.

2 lbs. per add-on

[ACTB]

SSTAO-409

Stainless steel tube add-on upgrades existing tube exchangers from titanium/aluminized to 409 grade stainless steel tubes. Tube clamp is stainless steel. MP, HL3, DX3 only. One needed per 10 ft. of tube. Sold as an add-on to an order. 2 lbs.

per add-on

[ACTB]

SSRAO

Specifying the stainless steel reflector add-on to your order upgrades the existing .025”, aluminum reflectors to highly polished, 304 grade stainless steel reflectors. Only sold as an add-on to an order. One SSRAO is needed per 10 ft. of reflector. For use on all models.

7 lbs. per add-on

[ACTB]

SSRAO-5Upgrade a 5 ft. aluminized reflector to 304 grade stainless steel.

[ACTB]

SSTRAO

Stainless steel tube & reflector add-on upgrades existing 10 ft. tube and reflector to stainless steel. Clamp is upgraded to stainless steel. One needed per 10 ft. of tube. Sold as an add-on and must be specified at the time of order. MP, HL3 and DX3 only.

9 lbs. per add-on

[ACTB]

SSTRAO-5

Upgrade a 5 ft. aluminized tube & reflector to 304 grade stainless steel. Clamp is upgraded to stainless steel.

PART NO. DESCRIPTION QTY.

[ACTB]

SSCBAO

Upgrade control housing box to second grade 304 grade stainless steel. Control box is silicone sealed and all electrical attachments are water-tight. NOTE: 16 in. tube is not upgraded to stainless without purchase of tube add-ons. Standard FC-24 is upgraded to FC-24PVC (pg. 7). For HL2, DX2, LD, LS models only.

[ACTB]

SSFWAO

Stainless steel fan wheel. Upgrade standard galvanized steel squirrel cage to stainless steel.

[ACTB]

SSC-##

Stainless steel tube clamps. Upgrade standard 4 in. galvanized steel tube clamps to 304 grade stainless steel.

See below

-10 -20 -30 -40 -50 -60 -70 -80

[ACTB]

SSB-##

Stainless steel mounting brackets. Upgrade standard galvanized steel 4 in. wire hanger (TP-19B) and 4 in. RCS (TP-82) to stainless steel. Prices shown below are per heater.

See below

-10 -20 -30 -40 -50 -60 -70 -80

REQuIRED STAINLESS STEEL ADD-ONS PER HEATER

MODEL 10 Ft. 20 Ft. 30 Ft. 40 Ft. 50 Ft. 60 Ft. 70 Ft. 80 Ft.

STRAIGHT 1 2 3 4 5 6 7 8

IMPORTANT NOTES• When ordering DX2 or HL2 models in 100% stainless steel, consult price

sheet for full heaters (-SS Series).• SSCBAO is only available for the HL2, DX2, LD and LS Series.• Upgrading tubes (SSTAO or SSTRAO) is available for MP, HL3 and DX3

Series only. Only available on 75,000 -150,000 BTu/hmodels, with the exception of 30-125 and 40-175 models.

• Upgrading reflectors (SSRAO) is available for all models.

When placing orders, please specify which heaters are to be upgraded.LD-LS Series: SSCBAO and SSRAO only. Tube and hanging accessories are not available in stainless steel.

Page 9: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

9

ELECTRICAL COMPONENTS AND MISCELLANEOuS CONTROL DEVICES

PART NO. DESCRIPTION QTY.

[ACCM]

4000-01V

40 VA transformer 120-24V. AC primary & secondary. Mounted on 4 x 4 base plate. Can be used for all 24V heaters or controls manufactured or provided by Detroit Radiant Products.

3 lbs.

[ACCM]

R8285B

Combination relay transformer, dual pole 15 resistive amps each pole. For controlling 120V units with 24V thermostats. 120V power in, 24V power out. U.L. Listed.

3 lbs.

[ACCP]

MTGRD

White Rodgers thermostat metal guard. Beige metal material with locking key. 3.8125”H x 6”W x 3.125”D. Mounts (vertical or horizontal) to exposed “J” box. Includes hardware.

3 lbs.

[ACCP]

F29GRD

White Rodgers thermostat guard. Clear plastic material with locking key. 5.375”H x 8.25”W x 3.5”D. Mounts (vertical or horizontal) to exposed “J” box. Includes hardware.

2 lbs.

[ACCP]

WCE-24

Weatherproof control enclosure capable of housing two switches of various types such as timer or on-off. Adapter plates included. Must be mounted to a suitable double gang box.

1 lb.

[ACCP]

WEP-TS

Weatherproof enclosure package with 4-hour timer and on-off control. Ideal for use in outdoor heating applications where timer control is desired. Package for two-stage scenarios. Can operate up to 120V-20 amp. Can also be used for 24V switching. Field assembly and wiring required.

2 lbs.

PART NO. DESCRIPTION QTY.

[ACCP]

SWPD60

Paragon Timer. Manually activated time control with white wall plate and knob. 60 minute twist timer with 5 minute increments. 120V - 20 amp (control up to 4 tube heaters) or 240 / 277 Volts -10 amps. Also compatible with 24V systems.

1 lb.

[ACCP]

SWPD-4H

Paragon Timer. Manually activated time control with white wall plate and knob. 4 hour twist timer. 120V - 20 amp (control up to 4 tube heaters) or 240 / 277 Volts -10 amps. Also compatible with 24V systems.

1 lb.

[ACCP]

LCD-3H

Energy saving snow switch allows heaters to operate only when required during snowfall (precipitation) and also when temperatures are below 38°F. The 3 amp device relay remains closed for a 1-hour hold-on time after the precipitation has stopped. 24VAC required for operation and switches a 24VAC signal. Multiple units can be operated from one device. 1 lb.

[ACCP]

TCP

Single or two-stage timer control panel for heaters without relays. 60-minute timer with manual switching between low and high fire as desired. Includes NEMA 4X enclosure (6”x6”x4”). Up to 4 - 120V or 24V.

8 lbs.

[ACCP]

TCP-B

Single or two-stage timer control panel for heaters with relays. 60-minute timer with manual switching between low and high fire as desired. Includes NEMA 4X enclosure (6”x6”x4”). Up to 8 - 24V with 40VA transformer.

8 lbs.

[ACCP]

BBS-AO

Black bulb sensor add-on. Upgrade remote sensor to be enclosed in a black bulb for jobs that require radiant temperature sensing inside a black bulb. This is compatible with controls that have temperature probes that can fit inside of the bulb casing. Contact factory for guidance.

8 lbs.

Page 10: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

10

SINGLE STAGE CONTROLS

PART NO. DESCRIPTION QTY.

[ACCP]

TH-PSD

LuxPro 24V non-programmable thermostat. 45°-90°F range. Single stage operation. 1.5 amp @ 24V AC (controls up to 10 heaters w/ 24VAO option and 40 VA transformer or 6 with R8285B). Features include °C/°F display and large illuminated display.

2 lbs.

[ACCP]

TH-1F78

24V Advanced programmable heat /cool digital T-Stat. 5-2 (4-Period) operation. 45°-90°F Range. Single stage operations. White color & LCD display. Covers wall marks left by most mechanical thermostats without the need for an extra wall plate.

2 lbs.

[ACCP]

TH-PSPLV

LuxPro 120V programmable line voltage thermostat. No relay transformer required. 5/2-day(4-period) operation. 45°-90°F range. Single stage operation,16 amp@ 120V, single pull. Features include °C/°F display, easy programming, timers, wall plate included and more. 120V only.

2 lbs.

[ACCP]

TH-1F80

24V or millivolt advanced programmable heat/cool digital T-Stat with batteries. 5+1+1 (4 Period) operation. 45°-90° F range. Single stage operation. White color, swing door and backlit LCD display. 24V - 1.5 amp (5 heaters w/24VAO & 40VA transformer). Features include °C or °F display, easy programming, 12/24 clock and temperature hold. 2 lbs.

[ACCP]

TH-ET5

Columbus Electric thermostat. 35° to 75°F range. White plastic cover, 125-277 VAC, 22.0 amps. May be used to switch either 24V, 120V or 220V. Consult amp rating of unit for proper sizing.

1 lb.

PART NO. DESCRIPTION QTY.

[ACCP]

TH-115

Thermostat with rain tight enclosure and 40° to 100°F range. Rugged weatherproof control for use in agricultural, industrial and commercial environments with heavy moisture atmospheres. 16.0 FLA, 25.0 amps resistive at 120V. NEMA 4X rated. Can be used with 24-277 VAC. Consult amp rating of unit for proper sizing. 2 lbs.

[ACCP]

TH-115-60B

Thermostat with rain tight enclosure and 0° to 120°F range. A 60” stainless steel sensing bulb for remote sensing is attached. Ideal for rugged, weatherproof control in outdoor or freeze protection applications. 16.0 FLA, 25.0 amps resistive at 120V. NEMA 4X rated. Can be used with 24-277 VAC. Consult amp rating of unit for proper sizing. 2 lbs.

[ACCP]

TH-T87

Honeywell 24V, single stage, heat/cool round manual thermostat. 40° to 90°F range, taupe color, temperature set and room temperature display. 1.0 amp with heat anticipator (controls up to 5 heaters w/ 24VAO and 40 VA transformer). Quick response, positive off, mercury free.

1 lb.

[ACCP]

WCP-A

WCP-B

WCP-C

Wal-Mart Control Packages

“A” Package: Includes T87, 4000-01V, SWPD60 and F29GRD.

“B” Package: Includes T-87, 4000-01V, and F29GRD.

“C” Package: Includes T87, 4000-01V, SWPD60 and MTGRD.

A

B

C

7 lbs.

HEATOFF

COOL

FAN

AUTOON

Compatible

Compatible

Compatible

Page 11: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

11

HLRB in burner box

HLRP in burner box

2 boards inside NEMA

(1) box

4 boards inside NEMA

(1) box

6 boards inside NEMA

(1) box

10 boards inside NEMA

(1) box

2 lbs. [ACTB]

HLRB

2 lbs. [ACTB]

HLRP

5 lbs. [ACCP]

HLPNL-2

7 lbs. [ACCP]

HLPNL-4

11 lbs. [ACCP]

HLPNL-6

12 lbs. [ACCP]

HLPNL-10

NOTE: When placing an order, be sure to specify which models will receive the HLRB/P. Replacement parts order TP-825/1325.

TWO-STAGE CONTROLS

PART NO. DESCRIPTION QTY.

[ACCP]

TH-BRTS

Braeburn non-programmable 24V two-stage heat/1 cool thermostat. 1 amp per terminal (3 amp max. load) allows operation of up to 8 two-stage heaters w/ HLRB/HLRP boards and transformer. 45° to 90°F (7°-32°C) heat/cool range. Operates on either constant 24VAC or two (2) AA alkaline batteries. Digital display, adjustable differential.

2 lbs.

[ACCP]

PSP-722

Lux Pro Millivolt or 24V programmable thermostat with batteries. 7-day (4-Period) operation. 40°-90°F range. 2 amps at 24V AC. (20 heaters w/HLRB and 4000-01V). Single or dual stage operation. Adjustable temperature differential (.25-2.25). Features include °C/°F display, easy programming, vacation, timers and “Energy Star” compliant.

2 lbs.

[ACCP]

TH-BR52

Braeburn two-stage or single-stage thermostat with flexible programming for residential and commercial applications. 7 Day, 5-2 Day or Non-Programmable. 45°-90°F control range. Indoor or outdoor remote sensing capable. Multi-Level keypad lockout. Bright blue backlight. Hardwire or battery powered. Meets California Title 24 guidelines. 2 lbs.

[ACCP]

RS-BR53

Indoor sensor for use with TH-BR52 thermostat. Mounts up to 200 ft. away. Sense Range of 40°-99°F depending on thermostat. Contemporary design for any decor.

2 lbs.

[ACCP]

RS-BR54

Outdoor sensor for use with TH-BR52 thermostat. Mounts outdoors up to 200 ft. away. Sense range capability of -40°-99°F depending on thermostat. Contemporary design for any decor

2 lbs.

0Hi-Low Relay Panels / BoardsRelay panels or boards must be used anytime two or more HL3 or LD heaters are operating on the same thermostat (or common vented). Relay panels are prewired and mounted inside one NEMA(1) enclosure. Available with 2 relays, 6 relays, or 10 relays per NEMA(1) box. Each relay can accommodate one heater. Each panel has one 40 VA transformer internally mounted. Relay boards (HLRB/HLRP) are (at the time of production) internally mounted into the burner box. This must be specified at the time of order. One board is needed per heater. An external transformer (eg. 4000-01V) is needed to power the control. Relay boards (HLRB/HLRP) are preferred over panels. NOTE: HLRB’s are not necessary on DET3 Series. Specify the HLRP for HL3 models only.

PART NO. DESCRIPTION QTY.

[ACCP]

ETD-5M

Columbus Electric two-stage, double throw, low or line voltage thermostat. 35°F to 75°F range (24, 120 or 220V). Non-adjustable, preset 2° high/low fire differential. UL Listed and CSA Certified.

2 lbs.

[ACCP]

TH-1F81

Programmable 24V single or two-stage thermostat with batteries. 4-period 5/2 programming. 24-1.0 amp (20 heaters w/HLRB/P & 40VA transformer). 45-90°F operation with preset 3 degree high-low differential. °C or °F display, vacation hold, easy programming and “Energy Star” compliant.

2 lbs.

[ACCP]

TH-109

Two-stage thermostat with rain tight, NEMA 4X enclosure. 40° to 100°F range. Rugged weatherproof control for use in agricultural, industrial, and commercial environments with heavy moisture atmospheres. Consult amp rating of unit for proper sizing. Can be used with 24-277 VAC.

2 lbs.

EMER

Page 12: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

12

PART NO. DESCRIPTION QTY.

[ACCP]

TH-1F95-TS

White Rogers Programmable MV-30V, single or two stage, touch-screen display thermostat with remote sensing. Adjustable temperature differential (0.6-1.2). 4 and 2 period; 7 or 5+1+1 day programming options. 1.5 amps per terminal allows operation of up to 30 two-stage heaters w/ HLRB boards and transformer. Used with one (1) remote sensor (RS-F145). 2 lbs.

[ACCP]

RS-F145

Remote sensor for use with TH-1F95-TS. For indoor use only. Sensor can be placed up to 200 feet away.

1 lb.

[ACCP]

RS-F145-OD

Remote sensor for use with TH-1F95-TS. For outdoor use. Sensor can be placed up to 200 feet away.

1 lb.

[ACCP]

TH-HWC2

Electronic temperature controller with 2 temperature inputs, 4 SPDT relays, single or two stage. 1 RS-SIS sensor included. 24,120 240V°F, max 2 sensors, heaters require 24VAO or HLRP.

2 lbs.

[ACCP]

RS-ODS

Remote 1097 ohm outdoor air temperature sensor for use with TH-HWC2 (probe mounted in weather-proof case).

2 lbs.

[ACCP]

RS-SIS

Remote 1097 ohm indoor air temperature sensor (probe only). For use with TH-HWC2.

1 lb.

[ACCP]

RS-WRS

Wall mount remote 1097 OHM air sensor for use with TH-HWC2 (probe mounted in case).

1 lb.

ADVANCED CONTROL OPTIONS

PART NO. DESCRIPTION QTY.

State-of-the-art pre-programed building management controller panel. Use as a stand-alone unit or part of an overall building management system. Features include a password protected LCD user interface with keypad, 4 daily set-points, runtime tracking, ability to label each zone, expandable, housed in a stylish and durable enclosure.

See 32, 74 & 116

interfaces below

[ACCP]

PCOXS-32

Designed to handle small applications. Accommodates up to 3 single stage / 2 dual stage heater zones. Maximum of 20 single stage / 10 dual stage heaters per zone.

[ACCP]

PCOXS-74

Designed to handle mid-sized applications. Accommodates up to 7 single stage / 4 dual stage heater zones. Maximum of 20 single stage / 10 dual stage heaters per zone.

[ACCP]

PCOXS-116

Designed to handle large applications. Accommodates up to 11 single stage/6 dual stage heater zones. Maximum of 20 single stage/10 dual stage heaters per zone.

[ACCP]

PCOXS-OP

Optional wall mounted display enables users to communicate with the PCOXS Controller up to 1600ft. away. Operator panel offers a graphic display providing management of each zone. User-friendly keypad allows zone parameters to be accessed and modified.

[ACCP]

PCOXS-RS

Deluxe wall mount 24V remote temperature sensor. 14°F to 158°F temperature range. Delivers a 4-20mA signal to controller up to 300 ft. 10Kohm.

1 lb.

[ACCP]

PCOXS-ODRS

Outdoor deluxe wall mount 24V remote temperature sensor. 14°F to 158°F temperature range. Delivers a 4-20mA signal to controller up to 300 ft. 10Kohm.

MP SERIES CONTROL OPTIONS

PART NO. DESCRIPTION QTY.

[ACCP]

TH-PUI

This advanced microprocessor based controller, loaded with powerful and custom features, is a smart logic controller that offers optimal performance out of your MP Series heater. Allows heater(s) to modulate will full PID controller that considers various inputs and outputs, utilizes the current set temperature (based on an on-board thermistor or an externally connected zone sensor), mode selected, and other variables to determine the rate of modulation. Optional integration with remote sensors (sold separately).

2 lbs.

PART NO. DESCRIPTION QTY.

[ACCP]

MP-P

Potentiometer. Used to control MP Series heater(s) in outdoor or spot heating environments to allow the user to manually control the heater’s firing rate based on the dial position.

1 lb.

[ACCP]

MP-T

Remote temperature sensor, 10kohm for use with the MP Series heater. Indoor use only.

1 lb.

[ACCP]

MP-T-OD

Remote temperature sensor, 10kohm for use with the MP Series heater. Indoor or outdoor use.

1 lb.

Page 13: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

13

ACCESSORIES uSED ONLY ON 3-INCH TuBE MODELS

PART NO. DESCRIPTION QTY.

[ACTB]

DB-TR60

Five foot heater extension assembly includes 5 ft., 16 ga., 3 in. diameter, aluminized steel tube with high temperature black coating, five foot reflector, 3 in. tube clamp and 3 in. hanger. Item can be shipped via UPS.

18 lbs.

[ACTP]

DB-10EA

Ten foot heater extension assembly includes ten foot, 16 gauge, 3 in. diameter, aluminized steel tube with high temperature black coating, ten foot reflector, 3 in. reflector center support, 3 in. tube clamp and one 3 in. hanger. This extension must be shipped via truck line. 1-4 can be packaged in one box. 37 lbs.

[ACTB]

DB-TF1B

180° bend (U) shaped fitting, used to make the heater into a U shaped configuration. 16 gauge aluminized steel, 3 in. diameter fitting, with high temperature black coating. Also included: 1 tube clamp, 1 wire hanger, 2 reflector endcaps, and clips. For use on a 3 in.-20 ft. model. Also see P/N: RU on page 6. 11 lbs.

[ACTB]

WVE-3

3 in. O.D. galvanized steel vent outlet cap with flapper. Flapper insures proper static pressure for proper unit operation. Must be used in unvented applications. Not for use in residential applications (all residential heaters must be externally vented). Also known as DB-WVE. 1 lb.

[ACTB]

DB-208

3 in. Duravent vent cap. Used for sidewall venting of the 3 in. Series models. Diameter is 7-3/4 in.

4 lbs.18 in. [ACTB]

DB-2093 in. x 18 in. doublewall B-vent. Used for penetrations through combustible walls or roofs while venting 3 in. models.

3 lbs.

60 in. [ACTB]

DB-BVP 8 lbs.

[ACTB]

DB-210

3 in. wall thimble. Used in conjunction with B-vent for penetrations through combustible walls and/or roofs.

3 lbs.

[ACTB]

DB-211

3 in. Duravent B to C adapter. This union is used to join C-vent with B-vent.

2 lbs.

[ACTB]

DB-213

3 in. x 3 ft. single wall C-vent. 22 gauge galvanized steel. Commonly referred to as “smoke pipe”. Not to be used for penetrations through a combustible wall or roof.

7 lbs.

[ACTB]

DB-DSK

3 in. vent package. Complete sidewall venting kit for lengths up to 12 feet. Includes: 1)DB-208, 1)DB-209, 1)DB-210, 1)DB-211, 3)DB-213 and 1)RTV-106 sealant. 30 in. assembled length.

10 lbs.

PART NO. DESCRIPTION QTY.

[ACTB]

DB-E6

Elbow package - 90° bend, 3 in. diameter, 16 gauge aluminized steel elbow with high temperature black coating. Includes 1) 3” tube clamp, 1) 3” hanger, 2) end caps w/clips.

7 lbs.

[ACTB]

DB-REP

Reflector and elbow package - 90° bend, 3 in., 16 gauge aluminized steel elbow with high temperature black coating and polished, one side bright reflector elbow, 8 mounting clips, one 3 in. tube clamp, and one hanger.

9 lbs.

[ACTB]

DB-RUP

Reflector and 3” O.D. 180° U-bend package. One DB-TF1B and one RU reflector cover. Polished one side bright. Reflectors cannot be rotated after installation of this accessory. Field assembly required.

11 lbs.

[ACTB]

DB-RVC

3 in. rooftop vent cap. All aluminum construction. For use on vertical rooftop vent applications only. Diameter is 7-1/4 in.

2 lbs.

[ACTB]

DB-FS

3 in. rooftop firestop spacer. For use with 3 in. venting through the ceiling. 8 in.x 8 in. square. Galvanized steel construction.

1 lb.

[ACTB]

DB-ARF

3 in. adjustable rooftop flashing. For use with 3 in. venting through the roof. Adjustable angle of flat to 6/12 pitch. Galvanized steel construction.

3 lbs.

[ACTB]

DB-SC

3 in. storm collar. For use with 3 in. venting through the roof. Prevents rain from entering flashing. Galvanized steel construction.

1 lb.

[ACTB]

DB-YSM

Dual exhaust assembly, “Y” shaped, 26 gauge galvanized steel, 3 in. O.D. x 4 in. O.D. x 3 in. O.D. Units connect at a 90° angle to the 3 in. leg. 4 in. vent connection is crimped for ease of vent hook-up. Adjustable elbows are not included. Heaters must share a common thermostat. 5 lbs.

[ACTB]

DB-VE

3 in., 90° vent elbow. 26 gauge galvanized steel, 3 in. O.D. allows for connection of vent pipe to roof vent packages. One end is crimped. DB-VE may not be substituted for DB-E6.

2 lbs.

[ACTB]

DB-RTVP

3 in. rooftop vent/intake package. Complete kit for vertical venting through roof. Includes: DB-211, DB-RVC, DB-FS, DB-ARF, DB-SC, DB-VE and RTV-106 sealant.

NOTE: B or C vent pipe material is not included.

7 lbs.

Note: An approved vent cap must be used when sidewall venting.Consult local codes when venting.

Page 14: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

14

4 INCH VENT MATERIALS

PART NO. DESCRIPTION QTY.

[ACTB]

WVE-GALV

Galvanized steel vent outlet cap 4 in. O.D. with flapper. Flapper insures proper static pressure for proper unit operation. Must be used with unvented units. Known as WVE-4.

2 lbs.

[ACTB]

SWD-4

Duravent sidewall vent cap. All aluminum construction. For use on all V3 models. Diameter is 8-3/4 in.

2 lbs.

[ACTB]

WT-4

4 in. wall thimble. Protection for venting through a sidewall application. Measures 8.5 in. outer diameter, 6.5 in. inner diameter. Adjustible 4 in. to 6 in. depth.

3 lbs.

[ACTB]

SK-4

Field Controls 4 in. vent terminal with internal screen. For use when sidewall venting. V2 200,000 Btu/h models only. Diameter is 10.25 in.

3 lbs.

[ACTB]

18BV-4

4 in. Doublewall B-vent. Used for penetrating through combustible wall and/or roofs. 18 in. long.

4 lbs.

[ACTB]

BVP-4

4 in. Doublewall “B” type vent. Used for penetrating through combustible wall and/or roofs. 60 in. long.

10 lbs.

[ACTB]

TF-9

4 in. side wall vent terminal with screen. 16 gauge aluminized steel construction, 18 in. long, one 4 in. clamp, with high temperature black coating. Bird screen on exhaust end. Not approved on V2 200,000 BTU/h models.

5 lbs.

[ACTB]

RRF

Rubber roof flashing for contoured or deck style roofs. Can be used with pipe diameters from 4.25 in. to 7.5 in.

3 lbs.

[ACTB]

RTVP-4

4 in. rooftop vent/intake package. Complete kit for vertical venting through the roof. Includes: RVC-4, DHC-4, FS-4, ARF-4, and SC-4, VE-4, RTV-106 sealant VT-4.

NOTE: Vent and B-vent must be ordered separately.

8 lbs.

PART NO. DESCRIPTION QTY.

[ACTB]

RVC-4

4 in. Simpson Duravent rooftop vent cap. All aluminum construction. For use on vertical rooftop vent applications only. For use on air intake or vent exhaust. Diameter is 8 in.

2 lbs.

[ACTB]

DHC-4

4 in. drafthood connector. B-C adapter for connecting vent pieces.

1 lb.

[ACTB]

FS-4

4 in. rooftop firestop spacer. For use with 4 in. venting through the ceiling. 8 in. x 8 in. square, galvanized steel construction.

2 lbs.

[ACTB]

ARF-4

4 in. adjustable rooftop flashing. For use with 4 in. venting through the roof. Galvanized steel. Adjustable angle of flat to 6/12 pitch.

4 lbs.

[ACTB]

SC-4

4 in. storm collar. For use with 4 in. venting through the roof. Galvanized steel. Prevents rain from entering flashing.

1 lb.

[ACTB]

VE-4

4 in. 90° vent elbow. 26 gauge galvanized steel, 4 in. O.D. allows for connection of vent pipe to roof unit packages. One end is crimped. VE-4 may not be substituted for E-6.

2 lbs.

[ACTB]

4GV60F

Duravent 4 in. Dura-connect flexible exhaust duct. Construction features: 60 in. long, .012 aluminum flex. Can be used with 4-DSK.

5 lbs.

[ACTB]

VT-4

4 in. vent tee with 4 in. clean out. 26 gauge galvanized steel vent pipe construction. For venting with cleanout requirements.

4 lbs.

[ACTB]

4-DSK

4 in. Duravent sidewall vent kit with all items for sidewall venting. Includes: SWD-4, WT-4, 18BV-4, DHC-4. No vent pipe material is included. 29 in. long when fully assembled.

NOT APPROVED FOR V2 200,000 Btu/h MODELS.

6 lbs.

Note: An approved vent cap must be used when sidewall venting.Consult local codes when venting.

Page 15: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

15

6 & 8 INCH VENT MATERIALS - DuAL VENT MATERIALS

PART NO. DESCRIPTION QTY.

[ACTB]

SWD-6

Duravent sidewall vent cap. All aluminum construction. For use on all V3 models. Diameter is 10.5 in.

3 lbs.

[ACTB]

SK-6

Field Controls 6 in. vent terminal with internal screen. Can only be used for dual side wall venting of V2 200,000 Btu/h models only. Diameter is 12.5 in.

3 lbs.

[ACTB]

WT-6

6 in. wall thimble. Protection for venting through a sidewall application.

4 lbs.[ACTB]

18BV-66 in. double wall B-vent. Used for penetrating through combustible wall/ roofs. 18 in. long. 6 lbs.

[ACTB]

BVP-6

6 in. double wall B-vent. Used for penetrating through combustible wall and/or roofs. 60 in. long. 12 lbs.

[ACTB]

VE-6

6 in. 90° vent elbow. 26 gauge galvanized steel, 6 in. O.D. allows for connection of vent pipe to roof unit packages. One end is crimped.

2 lbs.

[ACTB]

VT-6

6 in. Vent Tee with a 6 in. clean out. 26 gauge galvanized steel vent pipe construction. For venting with cleanout requirements.

4 lbs.

[ACTB]

RTVP-6

6 in. rooftop vent package. Complete kit for vertical venting through the roof. Includes: RVC-6, DHC-6, FS-6, ARF-6, and SC-6, VE-6 RTV-106 sealant VT-6. No vent pipe or B-vent material is included.

12 lbs.

PART NO. DESCRIPTION QTY.

[ACTB]

RVC-6

6 in. rooftop vent cap. All aluminum construction. For use on vertical rooftop vent applications only. Diameter is 11.5 in.

3 lbs.

[ACTB]

DHC-6

6 in. drafthood connector. B-C adapter for connecting vent pieces.

2 lbs.

[ACTB]

FS-6

6 in. rooftop firestop spacer. For use with 6 in. venting through the ceiling. 8 in. x 8 in. square. Galvanized steel construction.

2 lbs.

[ACTB]

ARF-6

6 in. adjustable rooftop flashing. For use with 6 in. venting through the roof. Adjustable angle of flat to 6/12 pitch. Galvanized steel construction.

5 lbs.

[ACTB]

SC-6

6 in. storm collar. For use with 6 in. venting through the roof. Prevents rain from entering flashing. Galvanized steel construction.

2 lbs.

[ACTB]

6-DSK

6 in. Duravent sidewall vent kit with all items for sidewall venting. Includes: SWD-6, WT-6, 18BV-6, DHC-6. No vent pipe material is included. 30 in. long when fully assembled.

NOT APPROVED FOR V2 200,000 Btu/h Models. 8 lbs.

[ACTB]

RTVP-8

8 in. rooftop vent package. Complete kit for vertical venting through the roof. Includes 8GVC drafthood connector, ARF-8 adjustable rooftop flashing, 8GVDC vent cap, 8GVFS firestop, 8GVSC storm collar, two YSM’s, two 6x6x8 sheet metal Y’s and two tubes of silicone sealant. B-vent must be ordered separately (60 in. BVP-8 ______). 20 lbs.

6 INCH VENT MATERIALS - COMMON VENT MATERIALS

PART NO. DESCRIPTION QTY.

[ACTB]

Y

Dual exhaust assembly, Y-shaped, 16 gauge aluminized steel. 4 in. O.D. x 6 in. O.D. x 4 in. O.D. Two tube clamps included. For use when common venting two heaters. Heaters must share a common thermostat. Dimensions - 21.5 in. left-right, 13 in. high.

11 lbs.

[ACTB]

RT

Dual exhaust assembly, r-shaped, 16 gauge aluminized steel with high temperature black coating 4 in. O.D. x 6 in. O.D. x 4 in. O.D. Two tube clamps included. For use when common venting two heaters that meet at a 90° angle. Heaters must share a common thermostat.

11 lbs.

PART NO. DESCRIPTION QTY.

[ACTB]

YSM

Dual exhaust assembly, Y-shaped, 26 gauge galvanized steel with baffle. 4 in. O.D. x 6 in. O.D. x 4 in. O.D. Two adjustable elbows included to ease installation. For use when common venting two heaters. Heaters must share a common thermostat. Dimensions - 14 in. left-right, 13 in. high. 8 lbs.

[ACTB]

RTSM

Dual exhaust assembly, 26 gauge galvanized steel, 4 in. O.D. x 6 in. O.D. x 4 in. O.D. One 4 in. unit connection at 45° angle to vertical stack, other 4 in. unit connection straight to 6 in. common/vertical stack. 6 in. vent connection is crimped for ease of vent hook-up. Two adjustable elbows included to ease installation. Heaters must share a common thermostat. 7 lbs.

Note: An approved vent cap must be used when sidewall venting.Consult local codes when venting.

Page 16: Tube Heater Packing List - Amazon Web Servicesreverberray.com.s3.amazonaws.com/.../2013/11/...Packing-List_7-13.pdfPacking List Replacement parts ... SERIES 20 FT. 30 FT. 40 FT. 50

16

BuRNER PRICING1 [TBAC]PART NO. DESCRIPTION QTY.

BRN-FT-BTu-GAS-MP MP Series Burner & Baffle

BRN-FT-BTu-GAS-HL2 HL2 Series Burner & Baffle

BRN-FT-BTu-GAS-HL3 HL3 Series Burner & Baffle

BRN-FT-BTu-GAS-DX2 DX2 Series Burner & Baffle

BRN-FT-BTu-GAS-DX3 DX3 Series Burner & Baffle

BRN-FT-BTu-GAS-XTS3 XTS3 Series Burner & Baffle

BRN-FT-BTu-GAS-DET3 DET3 Series Burner & Baffle

BRN-FT-BTu-GAS-DES3 DES3 Series Burner & Baffle

BRN-FT-BTu-GAS-LD LD Series Burner & Baffle

BRN-FT-BTu-GAS-LS LS Series Burner & Baffle

BRN-FT-BTu-GAS-RVA2 RVA2 Series Burner & Baffle

BRN-FT-BTu-GAS-SV SV Series Burner & Baffle

TuBE & REFLECTOR PACKAGES2 [ACTP]

ADDITIONAL KIT PRICING [ACTB]

PART NO. DESCRIPTIONSTANDARD

QTY.SSKAO

QTY.

DB-10Kit 10 Ft. Full 3” Mounting Kit N/A

DB-20Kit 20 Ft. Full 3” Mounting Kit N/A

DB-30Kit 30 Ft. Full 3” Mounting Kit N/A

10-Kit 10 Ft. Full 4” Mounting Kit

20-Kit 20 Ft. Full 4” Mounting Kit

30-Kit 30 Ft. Full 4” Mounting Kit

40-Kit 40 Ft. Full 4” Mounting Kit

50-Kit 50 Ft. Full 4” Mounting Kit

60-Kit 60 Ft. Full 4” Mounting Kit

70-Kit 70 Ft. Full 4” Mounting Kit

80-Kit 80 Ft. Full 4” Mounting Kit

MPKAOMP Series Kit Add-On. Substitutes (1) FC-24 with (1) FC-36.

N/A

Specify SSKAO when upgrading to Stainless Steel Kits.Additional Mounting Kit includes applicable hangers, clamps and center supports. Also included is (1) FC-24^, (2) reflector end caps, and (8) clips.

NOTE: Kits for 150-200 MBH models receive one stainless steel tube clamp.

^ FC-36 replaces FC-24 when MPKAO is specified.

1 Component burners do not include any mounting accessories.

PART NO. DESCRIPTION QTY.

TPK-A Type-10-HRT 35 lbs.

TPK-B Type-20-ALUM-HRT 70 lbs.

TPK-C Type-20-HRT 70 lbs.

TPK-D Type-30-ALUM-HRT 110 lbs.

TPK-E Type-40-ALUM-HRT 145 lbs.

TPK-F Type-40-TITAN-ALUM-HRT 145 lbs.

TPK-G Type-10-ALUM 35 lbs.

TPK-H Type-20-ALUM 70 lbs.

TPK-I Type-30-ALUM 110 lbs.

TPK-J Type-40-ALUM 145 lbs.

TPK-K Type-40-TITAN-ALUM 145 lbs.

TPK-BC Type-40-4-RVA 150 lbs.

TPK-BJ Type-40-4-ALUM-HRT-UCC 145 lbs.

TPK-BK Type-40-4-TITAN-ALUM-HRT-UCC 145 lbs.

TPK-BS Type-720-4-ALUM (no reflector) 185 lbs.

TPK-BT Type-720-4-HRT (no reflector) 185 lbs.

TPK-Bu Type-720-4-TITAN (no reflector) 185 lbs.

TPK-CR Type-10-3-TITAN 30 lbs.

TPK-CS Type-20-3-TITAN 65 lbs.

2 TPK Packages do not include any mounting accessories. Use caution to assure that the proper combustion chamber is utilized. In most cases - aluminized (50,000 to 125,000 BTU/h) or titanium (150,000 to 200,000 BTU/h) steel.

FACTORY CONVERSIONS

# CONV.

Net conversion fee to change BTU or gas type on new (less than 18 months), stock (never sold or used) heaters. Includes all labels, baffle changes and changes to burner. Does not include defective parts or new shipping cartons, if necessary. DRP does not pay any shipping fees. No switching between Series of heater (ex. DES3 to HL3) and no changes between low or high BTU models (50-100 = low, 125-200 = high). Do not return kit unless Detroit Radiant Products is to drop ship back to customer. Net pricing applies.

T1-CONV - BTU or Gas change only. Qty.____T2-CONV - High/Low Burner change. Qty.____

See T1 or T2-CONV

prices.

+ carton feeif necessary

LIMITED WARRANTY GuIDELINES AND OPTIONS4

STANDARD WARRANTY

BuRNER BOX COMPONENTS

TuBES/EXCHANGERS BuRNER

MP, HL3, DX3, 1 YEAR 5 YEARS 10 YEARS

LD, LS, SV 1 YEAR 3 YEARS 5 YEARS

HLV3 1 YEAR 5 YEARS 10 YEARS

DET3, DES3 1 YEAR 2 YEARS 3 YEARS

EXTENDED WARRANTY OPTIONS4

CWOControl Extended Warranty Option. (Max. 4 year extension) per year, per heater. QTY:__________

MPCWOMP Series Control Extended Warranty Option. (Max. 4 year extension) per year, per heater. QTY:__________

EWOExchanger Extended Warranty Option. (Max. 10 year total or 5 year extension) per year, per tube. QTY:__________

VPWO:HLV Vacuum Pump Extended Warranty Option (Max. 5 year total or 4 year extension) per year, per pump. QTY:_______

4 Prior approval from the factory is required when quoting extended warranties.

All limited warranties, are defined in the product insert manual for the particular series of heaters. Please contact the factory for further information on the terms and conditions.

3 Vacuum pump - 1 year.