TTJT Power Absorbtion Calculation Rev 1

Embed Size (px)

Citation preview

  • 8/19/2019 TTJT Power Absorbtion Calculation Rev 1

    1/2

    DESIGN DATA 

    Design Discharge Flow 4.00 m3/hr

    Design Pressure  6900 kPa

    Motor Service Factor 1.1

    Power @

     Design

     Pressure

     (kW)

     = 0.2777778

     x Rated

     Flow

     

    Rate(m3/hr) x Design Pressure / Pump Mechanical Efficiency / 

    1000 

    0.2777778 x 4.15 x 6900 /90%/ 1000 = 8.84

    Motor Power Required @ Design Pressure = Power @ Design 

    Pressure x Motor Service Factor  8.84 x 1.1 = 9.72

    Motor Power = 11 kW > 9.72

    RATED DATA 

    Rated Discharge Flow 4.15 m3/hr

    Rated Discharge Pressure  5000 kPa

    Rated Discharge Pressure 509.99 m

    Driver Speed  1469 rpm

    Pump Mechanical

     88%

    Volumetric 90%

    Reducer Efficiency derived from FAT  82%

    Motor Efficiency @ Load from Chart 91%

    PUMP SPECIFICATIONS 

    Pump Model BD‐28LC

    Piston Size, diameter 1.875"

    Pump Displacement  0.2749 l/rev

    RECORDED DATA 

    Crankshaft speed per pump (spm) 250

    Recorded Power Consumption  (kW) 8.8

    Actual Flow

     Rate

     (m3/hr)

     4.15

    CALCULATED DATA 

    Pump Brake Power recorded kW = Recorded Power kW  x Motor 

    Efficiency % x Gearbox Efficiency %  8.8 kW x 91% x 82% = 6.57 kW

    0.2777778 x Flow Rate(m3/hr) x Discharge Pressure / 1000 = 

    Pump Hydraulic Power (kW) 0.2777778 x 4.15 x 5000 / 1000  = 5.76 kW

    Pump Hydraulic Power /  (Pump Effi. x Reducer Effi. ) = Brake 

    Power ( Pump & Reducer Efficiency) (kW)  5.76 / (88% x 82% ) = 8.00 kW

  • 8/19/2019 TTJT Power Absorbtion Calculation Rev 1

    2/2

     

    Bemerkung

    Remark

    Motor Typ

    Motor type

    Bemessungsleistung

    rated output5,5 kW

    400 VBemessungstrom

    Rated current (CR)10,2  A  

    DrehzahlSpeed 1/minrpm Leistungsfaktor power factor   

    Frequenz

    Frequency50 HZ

    Polzahl

    Number of poles4

    Bemessungsmoment

    Rated torque (TR)36 Nm  

    Tag; Date Name; Name Nr.

    Bearb.;Designed 28.07.2015 Z001MMEY No.

    Gepr.; checked 28.07.2015 Z00225PY   B  u  c   h  s   t  a   b  e

       L  e   t   t  e  r

    Toleranzen nach/ Tolerances acc. to

    DIN IEC 38 - DIN EN 60 034-1

    Die Datenbasis ist eine Typenprüfung eines elektrisch identischen Motors

    0,87

    Leistungsfaktor-Wirkungsgrad-Leistung

    Power factor-Efficiency-Load

    The basis of the given values is a performance test of a electrical identical motor    D  a   t  u  m 

       D  a   t  e

    8931880-010

       N  a  m  e

       N  a  m  e

     ANGK-160MR-04M

    Bemessungsspannung

    rated voltage

    1465

    0,6

    0,7

    0,8

    0,9

    1

    60

    65

    70

    75

    80

    85

    90

    95

    100

    40 45 50 55 60 65 70 75 80 85 90 95 100 105 110

    P.F.EFF %

    BELASTUNG/LOAD (%)

    EFF %

    Power Factor.

     1469

     11,0

     20,5

     0,85

     72

    8932460-01003.08.2015

    03.08.2015