Portable Smart TSTLP ® ESE Tester INTRODUCTION: Portable Smart TSTLP ® ESE tester is designed to check that the main functions of the upgraded TSTLP ® ESE lightning rods are working properly and that none of the vital components is damaged (Results are given by both Green/Red light and ringing WARNING signal). INTERFACE ILLUSTRATION & SIZE Product Photo (FRONT) Product Photo (SIDE) Product Size: 130 mm*95 mm*53 mm FRONT Interface SIDE Interface TEST Test Button P Power Indication Lamp SWITCH Power Switch Button T Test Indication Lamp CHARGE Power Recharge Terminal UP-OK Upper Electrode Indication Lamp Output + +5VDC Power Output OK Indication Lamp Output - -5VDC Power Output LOW-OK Lower Electrode Indication Lamp OK Indication Lamp DEF Faulty Indication Lamp HOW TO TEST Below test, make sure making correct connection: 1: Connecting the tester with Power by the Power adapter (110V/220V/230V - 9V) or with 9V Portable Power Source( No need connection to the power if after charging (full)---Portable). 2: Insert the alligator clips into OUTPUT terminals (+/- could be exchanged) 3: Clamp the one alligator to the central rod of the TSTLP ® ESE terminal LOW ELECTRODES TEST: After above 1,2,3 connection, clamp THE OTHER ALLIGATOR to one of the lower electrodes of the TSTLP ® ESE terminal, press button SWITCH, Power Indication Lamp’s on, press T, it’s working OK if T& LOW-OK indication lamps’ on,which makes long-voice. It’s faulty if DEF indication lamp’s on,which makes several short-noise. Repeat same operation steps to rest lower electrodes till finished. UPPER ELECTRODES TEST: After above 1,2,3 connection, clamp THE OTHER ALLIGATOR to one of the upper electrodes of the TSTLP ® ESE terminal, press T, it’s working OK if T & UP-OK indication lamps’ on,which makes long-voice. It’s faulty if DEF indication lamp’s on,which makes several short-noise. Repeat same operation steps to rest upper electrodes till finished. TEST PHOTOS FOR REFERENCE: LOWER ELECTRODE TEST UPPER ELECTRODE TEST Start Future From Safety Professional Manufacturer TSTLP @ www.tslpro.com

TESTjapanese.ese-lightningrod.com/photo/ese-lightningrod/document/14… · TSTLP®ESEterminal,pressT,it’sworkingOKifT&UP-OKindicationlamps’on,whichmakeslong-voice. It’sfaultyifDEFindicationlamp’son,whichmakesseveralshort-noise.Repeatsameoperationstepstorest

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TESTjapanese.ese-lightningrod.com/photo/ese-lightningrod/document/14… · TSTLP®ESEterminal,pressT,it’sworkingOKifT&UP-OKindicationlamps’on,whichmakeslong-voice. It’sfaultyifDEFindicationlamp’son,whichmakesseveralshort-noise.Repeatsameoperationstepstorest

Portable Smart TSTLP® ESE Tester INTRODUCTION: Portable Smart TSTLP® ESE tester is designed to check that the main functions of

the upgraded TSTLP® ESE lightning rods are working properly and that none of the vital components isdamaged (Results are given by both Green/Red light and ringing WARNING signal).

INTERFACE ILLUSTRATION & SIZE

Product Photo (FRONT) Product Photo (SIDE)Product Size: 130 mm*95 mm*53 mm

FRONT Interface SIDE InterfaceTEST Test Button P Power Indication Lamp SWITCH Power Switch Button

T Test Indication Lamp CHARGE Power Recharge Terminal

UP-OKUpper Electrode Indication Lamp Output + +5VDC Power OutputOK Indication Lamp Output - -5VDC Power Output

LOW-OKLower Electrode Indication LampOK Indication Lamp

DEF Faulty Indication Lamp

HOWTO TESTBelow test, make sure making correct connection:1: Connecting the tester with Power by the Power adapter (110V/220V/230V - 9V) or with 9V Portable PowerSource( No need connection to the power if after charging (full)---Portable).2: Insert the alligator clips into OUTPUT terminals (+/- could be exchanged)3: Clamp the one alligator to the central rod of the TSTLP® ESE terminal

LOW ELECTRODES TEST:After above 1,2,3 connection, clamp THE OTHER ALLIGATOR to one of the lower electrodes of theTSTLP® ESE terminal, press button SWITCH, Power Indication Lamp’s on, press T, it’s working OK if T &LOW-OK indication lamps’ on,which makes long-voice. It’s faulty if DEF indication lamp’s on,which makesseveral short-noise. Repeat same operation steps to rest lower electrodes till finished.

UPPER ELECTRODES TEST:After above 1,2,3 connection, clamp THE OTHER ALLIGATOR to one of the upper electrodes of theTSTLP® ESE terminal, press T, it’s working OK if T & UP-OK indication lamps’ on,which makes long-voice.It’s faulty if DEF indication lamp’s on,which makes several short-noise. Repeat same operation steps to restupper electrodes till finished.

TEST PHOTOS FOR REFERENCE:

LOWER ELECTRODE

TEST

UPPER ELECTRODE

TEST