TS3200

  • Upload
    shamil

  • View
    215

  • Download
    0

Embed Size (px)

Citation preview

  • 7/23/2019 TS3200

    1/374

    IBM System Storage TS3100 Tape Library and TS3200Tape Library

    Setup, Operator, and Service Guide

    Machine Type 3573

    GA32-0545-12

  • 7/23/2019 TS3200

    2/374

  • 7/23/2019 TS3200

    3/374

    IBM System Storage TS3100 Tape Library and TS3200Tape Library

    Setup, Operator, and Service Guide

    Machine Type 3573

    GA32-0545-12

  • 7/23/2019 TS3200

    4/374

    Note!Before using this information and the product it supports, be sure to read the general information under "Notices" in theIBM System Storage TS3100 and TS3200 Tape Library Setup, Operator, and Service Guide.

    To ensure that you have the latest publications, visit the web at http://www.ibm.com/storage/.

    This edition applies to the IBM System Storage TS3100 Tape Library and TS3200 Tape Library Setup, Operator, andService Guide, GA32-0545-12, and to the subsequent releases and modifications until otherwise indicated in neweditions.

    Copyright IBM Corporation 2007, 2012.US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contractwith IBM Corp.

    http://www.ibm.com/storage/http://www.ibm.com/storage/http://www.ibm.com/storage/
  • 7/23/2019 TS3200

    5/374

    Read This First

    This product may not be certified in your country for connection by any meanswhatsoever to interfaces of public telecommunications networks. Further

    certification may be required by law prior to making any such connection.Please contact IBM for information.

    Minimum Firmware Levels for Common Library Features

    Table 1. Minimum Firmware Levels for common Library features

    Feature Minimum Firmware Level(s) Required

    Internet Protocol Security (IPsec) Library firmware must be greater than A.40

    Feature Codes 8049, 8148, and 8149 (LTOHH Tape Drives)

    Library firmware level must be at A.40, orgreater, to support Feature Codes 8049, 8148,and 8149 (LTO HH Tape Drives).

    LTO 6 Tape Drive Library firmware must be at B.50 or greaterto support the Ultrium 6 drives. Ensure theminimum version required to supportUltrium 6 tape drives are installed on thehost. Ensure that any host applications andsoftware using their own device drivers areat the minimum level required to supportUltrium 6 tape drives.

    LTO 5 Tape Drive Library firmware must be at 9.00, or greater,to support the Ultrium 5 drives. If using theIBM Tape Device Driver or ITDT (IBM TapeDiagnostic Tool), ensure the minimumversion required to support Ultrium 5 tapedrives are installed on the host. Ensure thatany host applications and software usingtheir own device drivers are at the minimumlevel required to support Ultrium 5 tapedrives.

    Library BCR (Bar Code Reader) Libraries manufactured after May 2010 mayhave a BCR that requires a minimum levelof library firmware. The minimum level offirmware for these libraries is 9.00. Attemptsto downlevel these libraries below 9.00 willbe blocked by the library.

    Dedicated Cleaning Slot removal Library firmware level must be greater than1.95.

    Encryption Library firmware level must be 4.0 orgreater.

    Drive firmware level must be 74H4 orgreater.

    Key Path Diagnostics Library firmware level must be greater than6.3.

    Copyright IBM Corp. 2007, 2012 iii

    |

    |

    |

    |

    |||

    |

    |

    |

    |

    |

    |

  • 7/23/2019 TS3200

    6/374

    Table 1. Minimum Firmware Levels for common Library features (continued)

    Feature Minimum Firmware Level(s) Required

    Path Failover (for one activation key forboth Control Path Failover and Data PathFailover)

    LTO 4 Tape Drives: No minimum level offirmware is required.

    LTO 3 Tape Drives: Drive firmware must begreater than 73P5.

    Library firmware levels greater than 1.95,but not greater than 8.xx support PathFailover on the TS3200 (3573-L4U) and FullHigh drives. Library firmware levels greaterthan 8.xx support Path Failover on theTS3100 and TS3200 (3573-L2U and 3573-L4U)for both Full High and Half High drives.

    Secure Socket Layer (SSL) over EncryptionKey Manager (EKM)

    Library firmware must be 6.3 or higher

    Accessing Online Technical Support

    For online Technical Support for your Library, visit:

    http://www.ibm.com/support/.

    Registering for My Notification

    My Notification registration provides email notification when firmware levels havebeen updated and are available for download and installation. To register for MyNotification:

    1. Visit the web athttp://www-01.ibm.com/software/support/einfo.html.

    2. Click My Notifications.

    Note: Library firmware and tape drive firmware are verified and releasedtogether. When updating to the latest firmware, verify that all installedcomponents such as tape drive(s), and library are at the latest levelsnoted on the Support web site. Mixing different levels of library and tapedrive firmware is not supported and may cause unpredictable results.

    Sending Us Your Comments

    Your feedback is important in helping to provide the most accurate and highestquality information. To submit any comments about this book or any otherTS3100/TS3200 documentation:

    v Send your comments by e-mail [email protected] sure to include the

    following information: Exact publication title and version

    Publication form number (for example, GA32-1234-02)

    Page, table, or illustration numbers that you are commenting on

    A detailed description of any information that should be changed

    Contacting IBM Technical Support

    In the USA: Call 1-800-IBM_SERV (1-800-426-7378).

    iv TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

    http://www.ibm.com/support/http://www.ibm.com/support/http://www-01.ibm.com/software/support/einfo.htmlhttp://www-01.ibm.com/software/support/einfo.htmlhttp://localhost/var/www/apps/conversion/tmp/scratch_1/[email protected]://localhost/var/www/apps/conversion/tmp/scratch_1/[email protected]://www-01.ibm.com/software/support/einfo.htmlhttp://www.ibm.com/support/
  • 7/23/2019 TS3200

    7/374

    Note: Before calling, complete all the steps in "Contacting IBM Technical Support"in chapter 9.

    All other Countries/Regions: Visit http://www.ibm.com.

    To open a Service Request online: Under Support & downloads, click on Open aservice request.

    Summary of Changes

    Table 2. Information added to the GA32-0545-12 edition

    v Support for LTO 6

    Specifications for Ultrium 6 drives

    Table 3. Information added to the GA32-0545-11 edition

    v Support for IPsec protocol

    IPsec configuration menu added to Web User interface

    Menu includes IPsec settings, IPsec policy, IKE settings, and ICMPv6 selectors

    Table 4. Information added to the GA32-0545-10 edition

    New Ultrium Half High drives:

    v Feature Code 8148 - Ultrium 4 HH Fibre Drive V2

    8Gb/s Fibre Channel, singe port

    v Feature Code 8149 - Ultrium 4 HH SS Drive V2

    6Gb/s SAS, dual port

    v Feature Code 8049 - Ultrium 3 HH SAS Drive V2

    6Gb/s SAS, dual port

    Read This First v

    ||

    |

    |

    |

    http://www-01.ibm.com/software/support/einfo.htmlhttp://www-01.ibm.com/software/support/einfo.htmlhttp://www-01.ibm.com/software/support/einfo.html
  • 7/23/2019 TS3200

    8/374

    Table 5. Information added to the GA32-0545-09 edition

    v Ultrium 5 Full High drives:

    8 Gb/s Fibre Channel - single port

    6 Gb/s Serial Attached SCSI (SAS) - dual port

    v Ultrium 5 Half High drives:

    8 Gb/s Fibre Channel - single port

    6 Gb/s SAS - dual port

    v Ultrium 5 media:

    1500 GB data capacity

    3000 GB data capacity with 2:1 compression

    v Path Failover feature enhancements:

    Support for Half High drives

    Support for TS3100 (3573-L2U)

    v Audit Logging

    The Configure Library SNMP web page includes the option to enable Audit Logging.

    When SNMP and Audit Logging are enabled, the library will send a trap for libraryand drive Configuration Change events.

    v Updated SNMP MIB information

    Configuration Change events

    Library Login events

    Library Logout events

    vi TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

  • 7/23/2019 TS3200

    9/374

    Contents

    Read This First . . . . . . . . . . . iiiMinimum Firmware Levels for Common Library

    Features . . . . . . . . . . . . . . . iiiAccessing Online Technical Support . . . . . . ivRegistering for My Notification . . . . . . . . ivSending Us Your Comments . . . . . . . . . ivContacting IBM Technical Support . . . . . . . ivSummary of Changes . . . . . . . . . . . v

    F i g u r e s . . . . . . . . . . . . . . . xi

    Tables . . . . . . . . . . . . . . . xv

    Safety and Environmental Notices xviiDanger Notice . . . . . . . . . . . . . xvii

    Caution Notice . . . . . . . . . . . . . xviiLaser Safety and Compliance . . . . . . . . xix

    Class I Laser Product . . . . . . . . . . xixPerforming the Safety Inspection Procedure . . . xixRack Safety . . . . . . . . . . . . . . xxProduct Recycling and Disposal . . . . . . . xxiiBattery Return Program . . . . . . . . . xxivMonitor Recycling or Disposal . . . . . . . xxvCautions and Regulatory Compliance Statementsfor NEBS . . . . . . . . . . . . . . xxvi

    P r e f a c e . . . . . . . . . . . . . . xxixRelated Publications . . . . . . . . . . . xxix

    Chapter 1. Product Description . . . . 1-1Front Panel . . . . . . . . . . . . . . 1-1Rear Panel . . . . . . . . . . . . . . 1-3Bar Code Reader . . . . . . . . . . . . 1-5Encryption . . . . . . . . . . . . . . 1-5Supported Internet Protocols . . . . . . . . 1-6SNMP Messaging . . . . . . . . . . . . 1-6

    SNMP Traps . . . . . . . . . . . . . 1-6Maximum Library Storage Capacity and DataTransfer Rate . . . . . . . . . . . . . 1-7Ultrium Tape Drives . . . . . . . . . . . 1-8

    Speed Matching . . . . . . . . . . . 1-9Channel Calibration . . . . . . . . . . 1-10Power Management . . . . . . . . . . 1-10

    Media . . . . . . . . . . . . . . . 1-10Library Specifications . . . . . . . . . . 1-11Product Environment . . . . . . . . . . 1-13Supported Servers, Operating Systems, andSoftware . . . . . . . . . . . . . . . 1-13Supported Device Drivers . . . . . . . . . 1-14

    Chapter 2. User Interfaces . . . . . . 2-1Operator Control Panel . . . . . . . . . . 2-1

    Operator Control Panel Philosophy . . . . . 2-1Power-ON Display. . . . . . . . . . . 2-2

    Note about the Front Panel LEDs . . . . . . 2-2Input Modes . . . . . . . . . . . . . 2-3

    Power ON/OFF . . . . . . . . . . . 2-4Web User Interface. . . . . . . . . . . . 2-4Login . . . . . . . . . . . . . . . 2-5System Status . . . . . . . . . . . . 2-6Web User Interface Help Pages . . . . . . 2-8Logging out of the Web User Interface . . . . 2-8

    Chapter 3. Installation Planning. . . . 3-1Determining the Number of Logical Libraries. . . 3-1

    Basic Guidelines . . . . . . . . . . . 3-1Library Sharing . . . . . . . . . . . . 3-1Using Multiple Logical Libraries for LibrarySharing . . . . . . . . . . . . . . 3-2

    Using Multiple Control Paths . . . . . . . . 3-2

    Using Multiple Control Paths for System i,iSeries, and AS/400 Attachment . . . . . . 3-2Using Multiple Control Paths for Path Failover 3-2

    Library Partitioning and Element Addressing . . . 3-3Using Persistent Binding to Ensure SCSI IDAssignment . . . . . . . . . . . . . 3-7

    Logical Unit Number (LUN) Scanning . . . . . 3-7Host Interfaces . . . . . . . . . . . . . 3-7

    SCSI Interface . . . . . . . . . . . . 3-8SAS Interface . . . . . . . . . . . . 3-10Fibre Channel Interface . . . . . . . . . 3-11

    Chapter 4. Installation and

    Configuration . . . . . . . . . . . 4-1Using the Library Configuration Form . . . . . 4-1Installing Your Library . . . . . . . . . . 4-1

    Choosing a Location . . . . . . . . . . 4-2Unpacking the Library . . . . . . . . . 4-2Verifying the Shipment . . . . . . . . . 4-3Installing the Library Foot Pads (for DesktopInstallation ONLY) . . . . . . . . . . . 4-3Removing and Storing the Shipping Lock . . . 4-4Rackmounting the Library (for Rack InstallationONLY) . . . . . . . . . . . . . . . 4-6Connecting the Host Interface Cable . . . . 4-14Connecting a Power Cord . . . . . . . . 4-17

    Configuring Your Library . . . . . . . . . 4-17

    Choosing Your Configuration Method . . . . 4-18Using Factory Defaults as Your Configuration 4-18Configuring Your Library using the Web UserInterface . . . . . . . . . . . . . . 4-18Configuring Your Library using the OperatorControl Panel . . . . . . . . . . . . 4-36

    Preparing the Host . . . . . . . . . . . 4-36Verifying the Connection . . . . . . . . . 4-36Cartridge Magazines. . . . . . . . . . . 4-37

    Populating the Library with Data Cartridges 4-41Inserting the Cleaning Cartridge. . . . . . 4-42

    Registering for My Notification . . . . . . . 4-43

    Copyright IBM Corp. 2007, 2012 vii

  • 7/23/2019 TS3200

    10/374

    Chapter 5. Operations . . . . . . . . 5-1Operator Control Panel Navigation . . . . . . 5-7Operator Control Panel Menu Tree . . . . . . 5-9

    Monitor Menu . . . . . . . . . . . . 5-10Control Menu . . . . . . . . . . . . 5-16Configure Menu . . . . . . . . . . . 5-18Service Menu . . . . . . . . . . . . 5-29

    Web User Interface Menus . . . . . . . . . 5-32Monitor Library Menu . . . . . . . . . 5-33Manage Library Menu . . . . . . . . . 5-42Configure Library Menu . . . . . . . . 5-44Service Library Menu . . . . . . . . . 5-69

    Import and Export Media during Normal LibraryOperation . . . . . . . . . . . . . . 5-77Configuring I/O Stations and Reserving Slots . . 5-78

    Chapter 6. Using Ultrium Media . . . . 6-1Data Cartridges . . . . . . . . . . . . . 6-1

    Cartridge Compatibility . . . . . . . . . 6-3Capacity Scaling . . . . . . . . . . . 6-3

    WORM (Write Once, Read Many) Cartridges . . . 6-3

    WORM Media . . . . . . . . . . . . 6-3Data Security on WORM Media . . . . . . 6-4WORM Media Errors . . . . . . . . . . 6-4Requirements for WORM Capability. . . . . 6-4

    Cleaning Cartridge. . . . . . . . . . . . 6-4Cartridge Memory Chip (LTO-CM) . . . . . . 6-5Bar Code Label . . . . . . . . . . . . . 6-5

    Guidelines for Using Bar Code Labels . . . . 6-7Write-Protect Switch . . . . . . . . . . . 6-7Handling the Cartridges . . . . . . . . . . 6-8

    Provide Training . . . . . . . . . . . 6-8Ensure Proper Packaging . . . . . . . . 6-9Provide Proper Acclimation and EnvironmentalConditions . . . . . . . . . . . . . 6-10

    Perform a Thorough Inspection . . . . . . 6-10Handle the Cartridge Carefully . . . . . . 6-11Examples of Cartridge Problems. . . . . . 6-11

    Repositioning or Reattaching a Leader Pin . . . 6-12Repositioning a Leader Pin . . . . . . . 6-12Reattaching a Leader Pin . . . . . . . . 6-14

    Environmental and Shipping Specifications forTape Cartridges . . . . . . . . . . . . 6-18Disposing of Tape Cartridges . . . . . . . . 6-19Ordering Media Supplies . . . . . . . . . 6-20

    Ordering Bar Code Labels . . . . . . . . 6-22

    Chapter 7. Troubleshooting . . . . . 7-1Installation Problems . . . . . . . . . . . 7-6Library Recovery Problem Determination . . . . 7-7Procedures for Isolating CRU Problems . . . . . 7-8

    Isolating a Power Supply Problem . . . . . 7-8Isolating Drive Sled Problems. . . . . . . 7-10Isolating a Library Controller Card vs. AccessorEnclosure Problem . . . . . . . . . . 7-11Isolating Web User Interface Problems . . . . 7-12Isolating Accessor Scanner Problems . . . . 7-13Isolating Host Attachment Interface Problems 7-13

    Identifying a Suspect Cartridge . . . . . . . 7-14

    Chapter 8. Error Codes . . . . . . . 8-1

    Chapter 9. Service Procedures . . . . 9-1Removing Cartridges from Magazine Slots. . . . 9-1Releasing the Magazines Manually . . . . . . 9-1IBM TotalStorage Tape Diagnostic Tool (ITDT) . . 9-3Contacting IBM Technical Support . . . . . . 9-4

    Chapter 10. Check, Adjust, Remove,and Replace . . . . . . . . . . . 10-1Tools Required. . . . . . . . . . . . . 10-1Electrostatic Discharge . . . . . . . . . . 10-1Relocating Your Library. . . . . . . . . . 10-1Removing/Installing/Adding a Tape Drive Sled 10-3

    Removing a Tape Drive Sled . . . . . . . 10-4Installing a Tape Drive Sled . . . . . . . 10-6Adding a Tape Drive Sled . . . . . . . . 10-9

    Removing the Slot Blocker - 2U Library . . . . 10-10Replacing a Power Supply . . . . . . . . 10-11Replacing a Library Controller Card . . . . . 10-12Replacing Cartridge Magazines. . . . . . . 10-14Replacing Magazine Fiducials . . . . . . . 10-14Replacing the Library Enclosure . . . . . . 10-15

    Preparing the Defective Library forReplacement . . . . . . . . . . . . 10-15Unpacking and Preparing the ReplacementLibrary Enclosure . . . . . . . . . . 10-16Installing Your Drive(s) in the ReplacementLibrary Enclosure . . . . . . . . . . 10-18Swapping Power Supplies . . . . . . . 10-21Swapping Library Controller Cards . . . . 10-22Swapping Cartridge Magazines. . . . . . 10-24Installing the Replacement Library Enclosure 10-27Completing the Installation of theReplacement Library Enclosure . . . . . . 10-28Returning the Defective Library Enclosure 10-29

    Chapter 11. Optional Features,Replacement Parts and Power Cords . 11-1

    Appendix A. Information for TrainedService Personnel . . . . . . . . . A-1Internal View of Library. . . . . . . . . . A-1Manual Cartridge Removal Procedure . . . . . A-2Recommended Tools . . . . . . . . . . . A-2Before You Begin . . . . . . . . . . . . A-2Beginning Procedure . . . . . . . . . . . A-3

    Removing the Drive Brick from the Sled . . . A-3Removing the Drive Cover . . . . . . . . A-6

    Full-high Drive: Tape Spooled Off Supply Reel . . A-7Half-high Drive: Tape Spooled Off Supply Reel A-8

    Full-high Drive: Tape Pulled from or Broken nearLeader Pin . . . . . . . . . . . . . . A-9

    Half-high Drive: Tape Pulled from or Brokennear Leader Pin . . . . . . . . . . . A-11

    Full-high Drive: Tape Broken in Mid-tape . . . A-13Half-high Drive: Tape Broken in Mid-tape A-14

    Full-high Drive: Tape Tangled along Tape Path A-15Half-high Drive: Tape Tangled along Tape Path A-18

    viii TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

  • 7/23/2019 TS3200

    11/374

    Full-high Drive: No Apparent Failure or Damageto Tape . . . . . . . . . . . . . . . A-19

    Half-high Drive: No Apparent Failure orDamage to Tape . . . . . . . . . . . A-22

    Ending Procedure . . . . . . . . . . . A-25Accessing the Library using Telnet . . . . . . A-25

    Appendix B. SCSI Element Types,SCSI Addresses, and PhysicalConfigurations . . . . . . . . . . . B-12U Library I/O Slot, Storage Slots and Drive SlotElement Addresses and Physical Locations . . . B-14U Library I/O Slots, Storage Slots, and Drive SlotsElement Addresses and Physical Locations . . . B-2Library Partitioning and Element Addressing. . . B-3

    Appendix C. TapeAlert Flags . . . . . C-1TapeAlert Flags Supported by the Library . . . . C-1TapeAlert Flags Supported by the Drive . . . . C-3

    Appendix D. Sense Data. . . . . . . D-1Library Sense Data . . . . . . . . . . . D-1Drive Sense Data . . . . . . . . . . . . D-7

    Appendix E. Message Retrieval at theHost . . . . . . . . . . . . . . . E-1Retrieving from an IBM System p or IBM PowerSystem with AIX . . . . . . . . . . . . E-1

    SCSI Sense Data Definition . . . . . . . . E-2SCSI Sense Data - Library Error . . . . . . E-2SCSI Sense Data - Drive Error . . . . . . . E-3

    Retrieving from a Sun System . . . . . . . . E-4Retrieving from an HP-UX System . . . . . . E-5Retrieving from an IBM System i or IBM Power

    System with IBM i OS . . . . . . . . . . E-5

    Appendix F. SNMP Status MIBVariables and Traps . . . . . . . . . F-1

    Appendix G. Library ConfigurationForm . . . . . . . . . . . . . . . G-1

    Appendix H. Accessibility . . . . . . H-1

    Notices . . . . . . . . . . . . . . I-1Trademarks . . . . . . . . . . . . . . I-3Electronic Emission Notices . . . . . . . . . I-4

    Federal Communications Commission statement I-4Industry Canada compliance statement . . . . I-4European Union Electromagnetic CompatibilityDirective . . . . . . . . . . . . . . I-4People's Republic of China Class A ElectronicEmission statement. . . . . . . . . . . I-6Taiwan Class A compliance statement . . . . I-6Taiwan contact information . . . . . . . . I-6Japan VCCI Council Class A statement . . . . I-7

    Japan Electronics and Information TechnologyIndustries Association (JEITA) Statement (lessthan or equal to 20 A per phase) . . . . . . I-7Japan Electronics and Information TechnologyIndustries Association (JEITA) Statement (greaterthan 20 A per phase) . . . . . . . . . . I-7Korean Communications Commission (KCC)Class A Statement . . . . . . . . . . . I-7Russia Electromagnetic Interference (EMI) ClassA Statement . . . . . . . . . . . . . I-8

    Glossary . . . . . . . . . . . . . J-1

    Index . . . . . . . . . . . . . . . X-1

    Contents ix

  • 7/23/2019 TS3200

    12/374

    x TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

  • 7/23/2019 TS3200

    13/374

    Figures

    1-1. Front panel of a 2U library . . . . . . 1-11-2. Front panel of a 4U library . . . . . . 1-1

    1-3. Rear panel (drive sled only) of a half highFibre Channel drive . . . . . . . . . 1-31-4. Rear panel of a 4U library with full high

    Fibre Channel drive and half high SASdrives . . . . . . . . . . . . . 1-3

    1-5. Rear panel of a 2U library with a full highdual port SAS drive . . . . . . . . . 1-3

    1-6. Library drive sled without ESD springs(SCSI sled shown) . . . . . . . . . 1-9

    1-7. Library drive sled with ESD springs [1](SAS sled shown) . . . . . . . . . 1-9

    2-1. Power-ON screens . . . . . . . . . 2-22-2. Web User Interface login page . . . . . 2-62-3. 2U library System Status screen . . . . . 2-6

    2-4. 4U library System Status screen . . . . . 2-62-5. 4U library System Status screen showing

    media attention status . . . . . . . . 2-72-6. 4U library System Status screen showing a

    power supply failure . . . . . . . . 2-73-1. Configuration of a one - partition system 3-43-2. Configuration of a two - partition system 3-53-3. Configuration of a three - partition system 3-53-4. Configuration of a four - partition system 3-63-5. Examples of SCSI element addressing 3-64-1. Installing foot pads on the bottom of the

    library enclosure . . . . . . . . . . 4-44-2. Shipping lock and label . . . . . . . 4-54-3. Library shipping lock and label storage

    location . . . . . . . . . . . . . 4-54-4. Rack Kit A mounting hardware . . . . . 4-64-5. Rack Kit B mounting hardware . . . . . 4-74-6. Examples of EIA units for round hole and

    square hole installations . . . . . . . 4-84-7. Rear view of Rack Kit A which shows the

    narrow part of the rail located at the rear ofthe rack.. . . . . . . . . . . . . 4-9

    4-8. Rear view of Rack Kit B shows a differentmounting method . . . . . . . . . 4-9

    4-9. Kit A (top picture with circles) showingrails installed. Rack Kit B is below showingthe front view of this kit installed. . . . 4-10

    4-10. 2U library rack anchors and mounting

    brackets . . . . . . . . . . . . 4-114-11. Close-up view of mounting of the anchors

    on both sides of the library . . . . . . 4-114-12. 2U library side screws to remove 4-124-13. Sliding the 2U library into the rack 4-124-14. Sliding the 4U library into the rack 4-134-15. Securing the 2U library to the rack 4-134-16. Securing the 4U library to the rack 4-144-17. Attaching a SCSI host interface cable to the

    2U library . . . . . . . . . . . . 4-154-18. Attaching host interface cables to the 4U

    library . . . . . . . . . . . . . 4-15

    4-19. Attaching a SAS interface cable to the 2Ulibrary . . . . . . . . . . . . . 4-15

    4-20. Interposer installation . . . . . . . . 4-164-21. Removing the protective label from thepower receptacle . . . . . . . . . 4-17

    4-22. Log in screen on the Web User Interface 4-214-23. The 2U library Configure Library: General

    screen . . . . . . . . . . . . . 4-234-24. Example: The 4U library Configure

    Library: General screen . . . . . . . 4-244-25. The 4U library Configure Library: Logical

    Libraries page . . . . . . . . . . 4-254-26. The Configure Library: Path Failover

    Feature Activation screen. . . . . . . 4-254-27. Feature Key verification screen. . . . . 4-254-28. Feature Activation Key screen . . . . . 4-27

    4-29. Configure Library: Encryption Activationscreen . . . . . . . . . . . . . 4-27

    4-30. The Configure Library: Drive screen 4-294-31. Configure Library: Network Page 4-304-32. Warning Screen . . . . . . . . . . 4-314-33. The Configure Library: User Access screen 4-324-34. The Configure Library: Date and Time

    screen . . . . . . . . . . . . . 4-334-35. The Configure Library: Logs and Traces

    screen . . . . . . . . . . . . . 4-334-36. The Configure Library: Email Notification

    screen . . . . . . . . . . . . . 4-344-37. Configure Library: SNMP Page 4-344-38. 2U library left magazine . . . . . . . 4-38

    4-39. 2U library right magazine . . . . . . 4-384-40. 2U library I/O Station in the left magazine 4-394-41. 4U library left magazines. . . . . . . 4-394-42. 4U library right magazines . . . . . . 4-404-43. 4U library I/O Station in the lower left

    magazine . . . . . . . . . . . . 4-404-44. Finger Holes on back side of 4U Library

    I/O Station . . . . . . . . . . . 4-415-1. 2U Library Control Keys . . . . . . . 5-85-2. 4U Library Control Keys . . . . . . . 5-85-3. Operator Control Panel Menu Tree 5-105-4. Monitor: Library menu . . . . . . . 5-115-5. Monitor: Drive menu . . . . . . . . 5-135-6. Example of a 4U Monitor: Inventory menu 5-15

    5-7. Overview of inventoried cartridges: Leftmagazines of a 4U Library . . . . . . 5-15

    5-8. Detailed information on cartridges residingin a magazine . . . . . . . . . . 5-16

    5-9. Control: I/O Station menu . . . . . . 5-165-10. Control: Move Cartridges menu 5-175-11. Control: Magazine menu . . . . . . . 5-185-12. Control: Re-Inventory menu. . . . . . 5-185-13. Configure: Logical Libraries menu 5-195-14. Configure: Library menu . . . . . . . 5-205-15. Configure: Drive menu . . . . . . . 5-235-16. Configure: Network menu . . . . . . 5-24

    Copyright IBM Corp. 2007, 2012 xi

    |

    ||

  • 7/23/2019 TS3200

    14/374

    5-17. Configure: Set Access PIN menu 5-255-18. Pound sign (#) shows accessible menus

    when access PIN is enabled but before it isentered. . . . . . . . . . . . . 5-26

    5-19. Configure: Save/Restore menu. . . . . 5-275-20. Configure: Set Date and Time menu 5-295-21. Configure: Path Failover . . . . . . . 5-295-22. Service: Library Verify menu . . . . . 5-305-23. Service: Run Tests menu . . . . . . . 5-305-24. Service: Service menu . . . . . . . . 5-315-25. Service: Display Contrast menu 5-325-26. The 4U library Monitor Library: Library

    Identity page . . . . . . . . . . . 5-345-27. The 4U library Monitor Library: Drive

    Identity page showing one V2 HH(Half-High) SAS (#1), one HH (Half-High)SCSI drive (#2), and one TD (Full-High)Fibre Channel drive (#3) . . . . . . . 5-36

    5-28. The 2U library Monitor Library: DriveIdentity page showing one Ultrium 3 HHSAS drive (#1) and one Ultrium 4 HH SASdrive (#2). Version 2 information displayedfor drive #1 identifies the drive as a V2drive (Feature Code 8049 - Ultrium 3 HHSAS Drive V2). . . . . . . . . . . 5-37

    5-29. The 4U library Monitor Library: LibraryStatus page . . . . . . . . . . . 5-38

    5-30. The 4U library Monitor Library: DriveStatus page . . . . . . . . . . . 5-40

    5-31. The 2U library Monitor Library: Inventorypage . . . . . . . . . . . . . 5-41

    5-32. The 4U library Monitor Library: Inventorypage (Right Magazines) . . . . . . . 5-42

    5-33. Manage Library: Move Media page 5-435-34. Manage Library: Perform Inventory page 5-43

    5-35. Manage Library: Release Magazine page 5-435-36. The 4U library Configure Library: Generaland Extended page. . . . . . . . . 5-45

    5-37. The 4U library Configure Library: LogicalLibraries page . . . . . . . . . . 5-46

    5-38. The 4U library Configure Library: PathFailover page . . . . . . . . . . 5-46

    5-39. Path Failover license verification page 5-475-40. Feature Activation Key screen . . . . . 5-485-41. Configure Library: Encryption Feature

    configuration screen . . . . . . . . 5-495-42. The Configure Library: Drives page for a

    2U library . . . . . . . . . . . . 5-515-43. The Configure Library: Drives page for a

    4U library . . . . . . . . . . . . 5-515-44. Configure Library: Network Page 5-525-45. Warning Screen . . . . . . . . . . 5-535-46. Configure Library: IPSec: The Policy

    setting page . . . . . . . . . . . 5-555-47. Generic IPSec settings . . . . . . . . 5-555-48. IPSec Policy Editing . . . . . . . . 5-565-49. Policy Editing . . . . . . . . . . 5-575-50. Overview of the policy configuration page 5-575-51. General Policy settings . . . . . . . 5-575-52. IKE settings . . . . . . . . . . . 5-605-53. Certificate Upload . . . . . . . . . 5-62

    5-54. Security Association settings . . . . . 5-625-55. Policy slot setup after saving one policy 5-645-56. Configure Library: User Access page 5-655-57. The Configure Library: Date & Time page 5-665-58. Configure Library: Logs & Traces page 5-665-59. Configure Library: Event Notification page 5-675-60. Configure Library: SNMP Page 5-685-61. Configure Library: Save/Restore page 5-695-62. No Cleaning Required . . . . . . . 5-695-63. No Cleaning Cartridge in Library 5-705-64. Service Library: Clean Drive page 5-705-65. Service Library: View Logs page 5-715-66. Service Library: View Drive Logs screen 5-715-67. Service: Save Drive Dump . . . . . . 5-725-68. Service Library: Perform Diagnostics page 5-735-69. Service Library: Perform Key Path

    Diagnostics page . . . . . . . . . 5-745-70. The 2U library Service Library: Upgrade

    Firmware page showing one Ultrium 3SAS Half High V2 drive and one Ultrium 4SAS Half High drive. . . . . . . . . 5-75

    5-71. The 4U library Service Library: UpgradeFirmware page . . . . . . . . . . 5-76

    5-72. The 2U library Monitor Library: DriveIdentity page showing one Ultrium 3 HHSAS drive (#1) and one Ultrium 4 HH SASdrive (#2). Version 2 information displayedfor drive #1 identifies the drive as a V2drive (Feature Code 8049 - Ultrium 3 HHSAS Drive V2). . . . . . . . . . . 5-76

    5-73. Service Library: Reboot page . . . . . 5-776-1. The IBM LTO Ultrium Data Cartridge 6-16-2. Ultrium Data and WORM Tape Cartridges 6-46-3. Sample bar code label on the LTO Ultrium 6

    Tape Cartridge . . . . . . . . . . 6-7

    6-4. Setting the write-protect switch . . . . . 6-86-5. Tape cartridges in a Turtlecase . . . . . 6-96-6. Double-boxing tape cartridges for shipping 6-106-7. Checking for gaps in the seams of a

    cartridge . . . . . . . . . . . . 6-116-8. Leader pin in the incorrect and correct

    positions . . . . . . . . . . . . 6-136-9. Placing the dislodged leader pin into the

    correct position . . . . . . . . . . 6-136-10. Rewinding the tape into the cartridge 6-146-11. Leader Pin Reattachment Kit . . . . . 6-156-12. Attaching the leader pin attach tool to the

    cartridge . . . . . . . . . . . . 6-166-13. Winding the tape out of the cartridge 6-17

    6-14. Removing the C-clip from the leader pin 6-176-15. Attaching the leader pin to the tape 6-187-1. A 250w power supply with LEDs 7-87-2. A 80w power supply without LEDs 7-99-1. Access holes for the left magazine 9-19-2. Access holes for the right magazine 9-29-3. Left magazine pulled out of the 2U library 9-39-4. Left Magazines pulled out of the 4U Library 9-310-1. ESD label . . . . . . . . . . . . 10-110-2. Shipping Lock and Label Storage Location 10-210-3. Shipping Lock and Label . . . . . . . 10-2

    xii TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

    ||

    ||

  • 7/23/2019 TS3200

    15/374

    10-4. Library drive sled without ElectroStaticDischarge (ESD) springs (SCSI sled shown) 10-3

    10-5. Library drive sled with ESD springs [1](SAS sled shown) . . . . . . . . . 10-4

    10-6. Drive sled components (full high fibredrive in top position, half high SCSI drivein middle position, half high SAS drive inbottom position) on back panel of a 4Ulibrary . . . . . . . . . . . . . 10-5

    10-7. Pulling the drive sled out of the library(drive sled without ESD springs shown) . 10-6

    10-8. Pushing the drive sled into the library(drive sled without ESD springs shown) . 10-7

    10-9. Diagrams for applying conductive tape forESD protection to the back of a drive sledinstalled in a 2U or 4U library . . . . . 10-8

    10-10. 2U Magazine with Slot Blocker 10-1010-11. Popping the Slot Blocker out of the Cell 10-1110-12. A power supply being removed from a

    2U library . . . . . . . . . . . 10-1210-13. A Library Controller Card being removed

    from the library . . . . . . . . . 10-1310-14. M agazine fiducial . . . . . . . . . 10-1410-15. Removing the two mounting bracket

    screws anchoring the library to the rack(one screw on each side of the library) . . 10-16

    10-16. Foot pads installed on the bottom of thelibrary enclosure . . . . . . . . . 10-17

    10-17. Removing the shipping label and lockfrom the top of the library and storing onthe rear panel . . . . . . . . . . 10-18

    10-18. Library shipping lock and label storagelocation on the real panel of the library . 10-18

    10-19. Removing a drive sled from the library(drive sled without ESD springs shown) . 10-19

    10-20. Drive sled taping diagrams . . . . . 10-2010-21. A power supply being removed from alibrary . . . . . . . . . . . . 10-21

    10-22. Removing a Library Controller Card fromthe library . . . . . . . . . . . 10-23

    10-23. Library front panel LEDs . . . . . . 10-2410-24. Access hole for the left magazine (facing

    rear of library) . . . . . . . . . . 10-2510-25. Access hole for the right magazine (facing

    rear of library) . . . . . . . . . . 10-2610-26. Left magazines pulled out of a 4U library

    (facing front of library) . . . . . . . 10-2710-27. Mounting brackets and anchors for

    securing the library in a rack (one bracket

    and anchor on each side of the library). . 10-28

    10-28. Front view of a rack showing the railsinstalled . . . . . . . . . . . . 10-28

    10-29. Proper placement of the RepairIdentification (RID) Tag . . . . . . . 10-29

    11-1. Types of Receptacles . . . . . . . . 11-8A-1. Internal view of the library . . . . . . A-1A-2. Drive connection card showing screws and

    plastic cover . . . . . . . . . . . A-4A-3. Half high drive with the connection card

    moved to the side showing the screws . . A-5A-4. The drive brick showing the cables to be

    unplugged. . . . . . . . . . . . A-5A-5. Removing the bezel and the cover from the

    4U internal drive . . . . . . . . . A-6A-6. Removing the bezel and the cover from the

    half high internal drive . . . . . . . A-7A-7. Using hex wrench to rewind tape into

    cartridge . . . . . . . . . . . . A-8A-8. Rewinding tape into cartridge . . . . . A-9A-9. Drive with cover removed to reveal gear

    train. . . . . . . . . . . . . . A-10A-10. Leader Block Assembly (LBA) . . . . . A-11A-11. Drive with cover removed to reveal gear

    train. . . . . . . . . . . . . . A-12A-12. Leader Block Assembly (LBA) A-13A-13. Using hex wrench to rewind tape into

    cartridge . . . . . . . . . . . . A-14A-14. Rewinding tape into cartridge A-15A-15. Using hex wrench to rewind tape into

    cartridge . . . . . . . . . . . . A-16A-16. Drive with cover removed to reveal gear

    train. . . . . . . . . . . . . . A-17A-17. Leader Block Assembly (LBA) A-18A-18. Rewinding tape into cartridge A-19A-19. Using hex wrench to rewind tape into

    cartridge . . . . . . . . . . . . A-20A-20. Drive with cover removed to reveal geartrain. . . . . . . . . . . . . . A-21

    A-21. Leader Block Assembly (LBA) A-22A-22. Rewinding tape into cartridge A-23A-23. Drive with cover removed to reveal gear

    train. . . . . . . . . . . . . . A-24A-24. Leader Block Assembly (LBA) A-24B-1. Configuration of a one - partition system B-4B-2. Configuration of a two - partition system B-5B-3. Configuration of a three - partition system B-5B-4. Configuration of a four - partition system B-6B-5. Examples of SCSI element addressing B-6E-1. AIX ERRPT Library Error Log Example E-3

    E-2. AIX ERRPT Library Error Log Example E-4

    Figures xiii

  • 7/23/2019 TS3200

    16/374

    xiv TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

  • 7/23/2019 TS3200

    17/374

    Tables

    1. Minimum Firmware Levels for commonLibrary features . . . . . . . . . . iii

    2. Information added to the GA32-0545-12edition . . . . . . . . . . . . . . v3. Information added to the GA32-0545-11

    edition . . . . . . . . . . . . . . v4. Information added to the GA32-0545-10

    edition . . . . . . . . . . . . . . v5. Information added to the GA32-0545-09

    edition . . . . . . . . . . . . . vi6. NEBS Compliance Statements . . . . . xxvi1-1. 2U library and 4U library front panel

    descriptions . . . . . . . . . . . 1-21-2. 2U library and 4U library rear panel

    descriptions . . . . . . . . . . . 1-41-3. Tape drive model and host interface type 1-7

    1-4. Library storage capacity and data transferrate . . . . . . . . . . . . . . 1-7

    1-5. Physical Specifications . . . . . . . . 1-111-6. Power Specifications . . . . . . . . 1-111-7. Operation Specifications: Ultrium 6 1-111-8. Operation Specifications: Ultrium 5 1-111-9. Operation Specifications: Ultrium 4 1-121-10. Operation Specifications: Ultrium 3 1-121-11. Environmental Specifications . . . . . 1-133-1. Host Drive Interface Support. . . . . . 3-83-2. Maximum bus length between terminators 3-93-3. Recommended maximum quantity of drives

    per SCSI bus . . . . . . . . . . . 3-94-1. Location criteria . . . . . . . . . . 4-2

    5-1. Menu navigation shortcuts . . . . . . 5-15-2. Library Control Keys . . . . . . . . 5-85-3. Detailed information on cartridges residing

    in a magazine . . . . . . . . . . 5-165-4. Factory Default Settings . . . . . . . 5-275-5. Web User Interface Menus . . . . . . 5-325-6. Library Identity page elements . . . . . 5-335-7. Drive Identity page elements . . . . . 5-345-8. Library Status page elements . . . . . 5-375-9. Drive Status page elements . . . . . . 5-385-10. Configure Library: General page elements 5-445-11. Configure Library: Specific page elements 5-445-12. Drive Identity page elements . . . . . 5-505-13. Generic IPSec settings . . . . . . . . 5-55

    5-14. General Policy settings . . . . . . . 5-585-15. IKE settings . . . . . . . . . . . 5-60

    5-16. Security Association settings . . . . . 5-626-1. Cartridge Types and Colors . . . . . . 6-1

    6-2. Cartridge Data Capacity and RecordingFormats . . . . . . . . . . . . . 6-26-3. Nominal Cartridge Life: Load/Unload

    Cycles . . . . . . . . . . . . . 6-36-4. Ultrium data cartridge compatibility with

    Ultrium tape drive . . . . . . . . . 6-36-5. Bar code label requirements for Ultrium

    tape drives and libraries . . . . . . . 6-56-6. Cartridges and VOLSERs compatible with

    the Ultrium Tape Drives . . . . . . . 6-66-7. Location of the write-protect switch 6-86-8. Environment for operating, storing, and

    shipping the LTO Ultrium Tape Cartridge . 6-196-9. Media supplies . . . . . . . . . . 6-20

    6-10. Authorized suppliers of custom bar codelabels . . . . . . . . . . . . . 6-22

    7-1. Troubleshooting table . . . . . . . . 7-17-2. Power Supply LED Meanings . . . . . 7-98-1. Main Error Codes . . . . . . . . . 8-28-2. Sub error codes . . . . . . . . . . 8-78-3. Warning Events . . . . . . . . . . 8-1110-1. Shipping Lock/Shipping Label . . . . . 10-211-1. Optional Features . . . . . . . . . 11-111-2. Replacement Parts . . . . . . . . . 11-211-3. Power Cords . . . . . . . . . . . 11-4A-1. Internal view description . . . . . . . A-1B-1. 2U library SCSI Element Types and Element

    Addresses . . . . . . . . . . . . B-1

    B-2. 4U library SCSI Element Types and ElementAddresses . . . . . . . . . . . . B-1

    B-3. 2U library SCSI element addresses forstorage slots and drive slot (one logicalpartition with one drive) . . . . . . . B-2

    B-4. 4U library SCSI element addresses forstorage slots and drive slot (one logicalpartition with drives in slot 1 and slot 2). . B-2

    C-1. TapeAlert Flags Supported by the UltriumTape Drive. . . . . . . . . . . . C-3

    D-1. Library Sense Keys, ASC and ASCQ D-1D-2. LTO Tape Drive Sense Data . . . . . . D-7E-1. AIX ERRPT Library Sense Data . . . . . E-3E-2. AIX ERRPT Drive Sense Data . . . . . E-4

    F-1. SNMP Status Events . . . . . . . . F-1

    Copyright IBM Corp. 2007, 2012 xv

    |

    ||

    ||

  • 7/23/2019 TS3200

    18/374

    xvi TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

  • 7/23/2019 TS3200

    19/374

    Safety and Environmental Notices

    When using this product, observe the danger, caution, and attention notices thatare contained in this guide. The notices are accompanied by symbols that represent

    the severity of the safety condition.

    Most danger or caution notices contain a reference number (Dxxxx or Cxxxx). Usethe reference number to check the translation in the IBM Systems Safety Information(G229-9054) publication included in your ship group.

    The sections that follow define each type of safety notice and give examples.

    Danger Notice

    A danger notice calls attention to a situation that ispotentially lethal or extremely hazardous to people. A

    lightning bolt symbol always accompanies a danger noticeto represent a dangerous electrical condition.

    Caution Notice

    A caution notice calls attention to a situation that is potentially hazardous topeople because of some existing condition. A caution notice can be accompanied

    by one of several symbols:

    If the symbol is... It means....

    A hazardous electrical condition with less severity than electricaldanger.

    A generally hazardous condition not represented by other safetysymbols.

    A hazardous condition due to the use of a laser in the product. Lasersymbols are always accompanied by the classification of the laser asdefined by the U. S. Department of Health and Human Services (forexample, Class I, Class II, and so forth).

    A hazardous condition due to mechanical movement in or around theproduct.

    svc

    00168

    32-55 kg (70.5-121.2 lbs)

    A hazardous condition due to the weight of the unit. Weight symbolsare accompanied by an approximation of the product's weight.

    Copyright IBM Corp. 2007, 2012 xvii

  • 7/23/2019 TS3200

    20/374

    If the symbol is... It means....

    A hazardous condition due to the unit's susceptibility to electrostaticdischarge.

    xviii TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

  • 7/23/2019 TS3200

    21/374

    Laser Safety and Compliance

    Before using the library, review the following laser safety information.

    Class I Laser ProductThe library may contain a laser assembly that complies with the performance

    standards set by the U.S. Food and Drug Administration for a Class I laserproduct. Class I laser products do not emit hazardous laser radiation. The libraryhas the necessary protective housing and scanning safeguards to ensure that laserradiation is inaccessible during operation or is within Class I limits. External safetyagencies have reviewed the library and have obtained approvals to the lateststandards as they apply.

    Performing the Safety Inspection Procedure

    Before you service the unit, perform the following safety inspection procedure:

    1. Stop all the activities between the host and the library's tape drives.

    2. Turn off the power to the library by pushing in on the Powerbutton (1)shown in Figure 1-1 on Page 1-1 for 4 seconds.

    3. If drives are SCSI attached, disconnect the SCSI cable and check the SCSI busterminator for damage.

    4. Unplug the library's power cord or cords from the electrical outlet and thelibrary power supply.

    5. Check the library's power cord for damage, such as a pinched, cut, or frayedcord.

    6. If drives are SCSI attached, check the tape drive's SCSI bus (signal) cable fordamage.

    7. If drives are FC/SAS attached, check the tape drive's FC/SAS cable fordamage.

    8. Check the cover of the library for sharp edges, damage, or alterations that

    expose its internal parts.

    9. Check the cover of the library for proper fit. It should be in place and secure.

    10. Check the product label at the rear of the library to make sure that it matchesthe voltage at your outlet.

    Safety and Environmental Notices xix

  • 7/23/2019 TS3200

    22/374

    Rack Safety

    The following general safety information should be used for all rack mounteddevices.

    DANGER

    v Always lower the leveling pads on the rack cabinet.v Always install stabilizer brackets on the rack cabinet.

    v To avoid hazardous conditions due to unevenmechanical loading, always install the heaviestdevices in the bottom of the rack cabinet. Alwaysinstall servers and optional devices starting from thebottom of the rack cabinet.

    v Rack mounted devices are not to be used as a shelfor work space. Do not place any object on top of rackmounted devices.

    v Each rack cabinet might have more than one powercord. Ensure that all power cords in the rack cabinetare disconnected before servicing any device in the

    rack cabinet.

    v Connect all devices installed in a rack cabinet topower devices installed in the same rack cabinet. Donot plug a power cord from a device installed in onerack cabinet into a power device installed in adifferent rack cabinet.

    v An electrical outlet that is not correctly wired couldplace hazardous voltage on the metal parts of thesystem or the devices that attach to the system. It isthe responsibility of the customer to ensure that theoutlet is correctly wired and grounded to prevent anelectrical shock.

    xx TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

  • 7/23/2019 TS3200

    23/374

    CAUTION:

    v Do not install a unit in a rack where the internal rackambient temperatures WILL exceed the manufacturer'srecommended ambient temperature for all your rackmounted devices.

    v Do not install a unit in a rack where the air flow iscompromised. Ensure that air flow is not blocked or

    reduced on any side of the unit.

    v Connect the equipment to the supply circuit such thatoverloading of the circuits does not compromise thesupply wiring or overcurrent protection. To provide thecorrect power connection to a rack, refer to the ratinglabels located on the equipment in the rack to determinethe total power requirement of the supply circuit.

    v (For sliding drawers) Do not pull out or install any draweror feature if the rack stabilizer brackets are not attachedto the rack. Do not pull out more than one drawer at atime. The rack may become unstable if you pull outmore than one drawer at a time.

    v (For fixed drawers) Do not move a fixed drawer.

    Attempting to move the drawer partially or completelyout of the rack may cause the rack to become unstableor cause the drawer to fall out of the rack.

    (R001)

    Safety and Environmental Notices xxi

  • 7/23/2019 TS3200

    24/374

    CAUTION:Removing components from the upper positions in therack cabinet improves rack stability during relocation.Follow the general guidelines as listed below wheneveryou relocate a populated rack cabinet within a room orbuilding:

    v Reduce the weight of the rack cabinet by removing

    equipment starting at the top of the rack cabinet. Whenpossible, restore the rack cabinet to the configuration ofthe rack cabinet as you received it. If this configurationis not known, you must do the following:

    Remove all devices in the 32U position and above.

    Ensure that the heaviest devices are installed in thebottom of the rack cabinet.

    Ensure that there are no empty U-levels betweendevices installed in the rack cabinet below the 32Ulevel.

    v If the rack cabinet you are relocating is part of a suite ofrack cabinets, detach the rack cabinet from the suite.

    v Inspect the route that you plan to take to eliminatepotential hazards.

    v Verify the route that you choose can hold the weight ofthe loaded rack cabinet. Refer to the documentation thatcomes with your rack cabinet for the weight of a loadedrack cabinet.

    v Verify that all door openings are at least 762 x 2032 mm(30 x 80 inches).

    v Ensure that all devices, shelves, drawers, doors, andcables are secure.

    v Ensure that the four leveling pads are raised to theirhighest position.

    v Ensure that there is no stabilizer bracket installed on the

    rack cabinet during movement.v Do not use a ramp inclined at more than ten degrees.

    v Once the rack cabinet is in the new location, do thefollowing:

    Lower the four leveling pads.

    Install stabilizer brackets on the rack cabinet.

    If you remove any of the devices from the rackcabinet, repopulate the rack cabinet from the lowestposition to the highest position.

    v If a long distance relocation is required, restore the rackcabinet to the configuration of the rack cabinet as youreceived it. Pack the rack cabinet in the originalpackaging material, or equivalent. Also lower theleveling pads to raise the casters off of the pallet andbolt the rack cabinet to the pallet.

    (R002)

    Product Recycling and Disposal

    This unit contains recyclable materials.

    xxii TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

  • 7/23/2019 TS3200

    25/374

    This unit must be recycled or discarded according to applicable local and nationalregulations. IBM encourages owners of information technology (IT) equipment toresponsibly recycle their equipment when it is no longer needed. IBM offers avariety of product return programs and services in several countries to assistequipment owners in recycling their IT products. Information on IBM productrecycling offerings can be found on IBM's Internet sites at http://www.ibm.com/ibm/recycle/us/index.shtmland http://www.ibm.com/ibm/environment/products/index.shtml

    Note: This paragraph is also translated into Spanish as follows:

    Esta unidad debe reciclarse o desecharse de acuerdo con lo establecido en lanormativa nacional o local aplicable. IBM recomienda a los propietarios deequipos de tecnologa de la informacin (TI) que reciclen responsablementesus equipos cuando stos ya no les sean tiles. IBM dispone de una serie deprogramas y servicios de devolucin de productos en varios pases, a fin deayudar a los propietarios de equipos a reciclar sus productos de TI. Sepuede encontrar informacin sobre las ofertas de reciclado de productos deIBM en el sitio web de IBM http://www.ibm.com/ibm/environment/products/index.shtml

    Notice:This mark applies only to countries within the European Union (EU) andNorway.

    Appliances are labeled in accordance with European Directive 2002/96/ECconcerning waste electrical and electronic equipment (WEEE). The Directivedetermines the framework for the return and recycling of used appliances asapplicable throughout the European Union. This label is applied to variousproducts to indicate that the product is not to be thrown away, but ratherreclaimed upon end of life per this Directive.

    Remarque : Cette marque sapplique uniquement aux pays de lUnion Europenneet la Norvge.

    Letiquette du systme respecte la Directive europenne 2002/96/EC en matire deDchets des Equipements Electriques et Electroniques (DEEE), qui dtermine lesdispositions de retour et de recyclage applicables aux systmes utiliss travers

    lUnion europenne. Conformment la directive, ladite tiquette prcise que leproduit sur lequel elle est appose ne doit pas tre jet mais tre rcupr en fin devie.

    Safety and Environmental Notices xxiii

  • 7/23/2019 TS3200

    26/374

    In accordance with the European WEEE Directive, electrical and electronicequipment (EEE) is to be collected separately and to be reused, recycled, orrecovered at end of life. Users of EEE with the WEEE marking per Annex IV of theWEEE Directive, as shown above, must not dispose of end of life EEE as unsortedmunicipal waste, but use the collection framework available to customers for thereturn, recycling and recovery of WEEE. Customer participation is important tominimize any potential effects of EEE on the environment and human health dueto the potential presence of hazardous substances in EEE. For proper collection andtreatment, contact your local IBM representative.

    Battery Return Program

    This product may contain sealed lead acid, nickel cadmium, nickel metal hydride,

    lithium, or a lithium ion battery. Consult your user manual or service manual forspecific battery information. The battery must be recycled or disposed of properly.Recycling facilities may not be available in your area. For information on disposalof batteries outside the United States, go to http://www.ibm.com/ibm/environment/

    products/index.shtmlor contact your local waste disposal facility.

    In the United States, IBM has established a return process for reuse, recycling, orproper disposal of used IBM sealed lead acid, nickel cadmium, nickel metalhydride, and other battery packs from IBM Equipment. For information on properdisposal of these batteries, contact IBM at 1-800-426-4333. Please have the IBM partnumber listed on the battery available prior to your call.

    For the European Union:

    For Taiwan:

    Please recycle batteries

    Batteries or packaging for batteries are labeled in accordance with EuropeanDirective 2006/66/EC concerning batteries and accumulators and waste batteries

    xxiv TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

  • 7/23/2019 TS3200

    27/374

    and accumulators. The Directive determines the framework for the return andrecycling of used batteries and accumulators as applicable throughout theEuropean Union. This label is applied to various batteries to indicate that the

    battery is not to be thrown away, but rather reclaimed upon end of life per thisDirective.

    Les batteries ou emballages pour batteries sont tiquets conformment aux

    directives europennes 2006/66/EC, norme relative aux batteries et accumulateursen usage et aux batteries et accumulateurs uss. Les directives dterminent lamarche suivre en vigueur dans l'Union Europenne pour le retour et le recyclagedes batteries et accumulateurs uss. Cette tiquette est applique sur diverses

    batteries pour indiquer que la batterie ne doit pas tre mise au rebut mais pluttrcupre en fin de cycle de vie selon cette norme.

    In accordance with the European Directive 2006/66/EC, batteries and accumulatorsare labeled to indicate that they are to be collected separately and recycled at endof life. The label on the battery may also include a chemical symbol for the metalconcerned in the battery (Pb for lead, Hg for mercury and Cd for cadmium). Usersof batteries and accumulators must not dispose of batteries and accumulators asunsorted municipal waste, but use the collection framework available to customersfor the return, recycling and treatment of batteries and accumulators. Customerparticipation is important to minimize any potential effects of batteries andaccumulators on the environment and human health due to the potential presenceof hazardous substances. For proper collection and treatment, contact your local

    IBM representative.

    Spain

    This notice is provided in accordance with Royal Decree 106/2008 of Spain: Theretail price of batteries, accumulators and power cells includes the cost of theenvironmental management of their waste.

    Perchlorate Material - California

    Special handling may apply. See http://www.dtsc.ca.gov/hazardouswaste/perchlorate formore information.

    The foregoing notice is provided in accordance with California Code ofRegulations Title 22, Division 4.5 Chapter 33. Best Management Practices forPerchlorate Materials. This product/part may include a lithium manganese dioxide

    battery which contains a perchlorate substance.

    Monitor Recycling or Disposal

    Flat panel display

    Safety and Environmental Notices xxv

  • 7/23/2019 TS3200

    28/374

    The fluorescent lamp or lamps in the liquid crystal display contain mercury.Dispose of it as required by local ordinances and regulations.

    Monitors and workstations

    New Jersey - For information about recycling covered electronic devices in theState of New Jersey, go to the New Jersey Department of Environmental Protection

    web site at http://www.state.nj.us/dep/dshw/recycle/Electronic_Waste/index.html

    Oregon - For information regarding recycling covered electronic devices in thestate of Oregon, go to the Oregon Department of Environmental Quality site athttp://www.deq.state.or.us/lq/electronics.htm

    Washington State - For information about recycling covered electronic devices inthe State of Washington, go to the Department of Ecology Web site athttp://www.ecy.wa.gov/programs/swfa/productrecycle or telephone the WashingtonDepartment of Ecology at 1-800Recycle.

    IBM Cryptographic Coprocessor Card return program

    This machine may contain an optional feature, the cryptographic coprocessor cardwhich includes a polyurethane material that contains mercury. Please follow LocalOrdinances or regulations for disposal of this card. IBM has established a returnprogram for certain IBM Cryptographic Coprocessor Cards. More information can

    be found at http://www.ibm.com/ibm/environment/products/recycling.shtml

    Cautions and Regulatory Compliance Statements for NEBS

    This library is NEBS certified. This section includes the cautions and regulatorycompliance statements for the Network Equipment-Building System (NEBS)certification from the Telcordia Electromagnetic Compatibility and Electrical Safety- Generic Criteria for Network Telecommunications Equipment (A Module of

    LSSGR, FR-64; TSGR, FR-440; and NEBSFR, FR-2063) Telcordia TechnologiesGeneric Requirements, GR-1089-CORE, Issue 4, June 2006.

    Table 6. NEBS Compliance Statements

    Caution:To comply with the Telcordia GR-1089-CORE standard for electromagneticcompatibility and safety, for Ethernet RJ-45 ports, use only shielded Ethernet cables that aregrounded on both ends. In a NEBS installation, all Ethernet ports are limited tointra-building wiring.

    Caution:The intra-building ports of the equipment or subassembly are only suitable forconnection to intra-building or unexposed wiring or cabling. The intra-building ports ofthe equipment or subassembly MUST NOT be metallically connected to interfaces thatconnect to the OSP or its wiring. These interfaces are designed for use only asintra-building interfaces (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 4),and require isolation from the exposed OSP cabling. The addition of primary protectors isnot sufficient protection in order to connect these interfaces metallically to OSP wiring.

    xxvi TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

  • 7/23/2019 TS3200

    29/374

    Table 6. NEBS Compliance Statements (continued)

    An external Surge Protective Device (SPD) is not required for operating this library.

    This product can be installed in a network telecommunication facility or location where theNEC applies.

    Safety and Environmental Notices xxvii

  • 7/23/2019 TS3200

    30/374

    xxviii TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

  • 7/23/2019 TS3200

    31/374

    Preface

    This manual contains information and instructions necessary for the installation,operation, and service of the IBM System Storage TS3100 Tape Library and

    TS3200 Tape Library.

    Note: The IBM System Storage TS3100 Tape Library and TS3200 Tape Library is acustomer installed unit. The customer is responsible for the setup andmaintenance of the tape library. The customer will be charged for service if aservice contract is not in place.

    Related Publications

    Refer to the following publications for additional information. To ensure that youhave the latest publications, visit the web at http://www.ibm.com/storage/.

    v IBM System Storage TS3100 Tape Library and TS3200 Tape Library Getting Started

    Guide(GA32-0546) provides installation information.v IBM System Storage TS3100 Tape Library and TS3200 Tape Library SCSI Reference

    (GA32-0547) provides supported SCSI commands and protocol governing thebehavior of SCSI interface.

    v IBM TotalStorage LTO Ultrium Tape Drive SCSI Reference (GA32-0450) providessupported SCSI commands and protocol governing the behavior of SCSIinterface for the tape drive.

    v IBM Tape Device Driver Installation and User's Guide(GC27-2130) providesinstructions for attaching IBM-supported hardware to open-systems operatingsystems. It indicates what devices and levels of operating systems are supported.It also gives requirements for adapter cards, and tells how to configure hosts touse the device driver. All of the above are with the Ultrium family of devices.

    v IBM Tape Device Driver Programming Reference(GA32-0566) supplies informationto application owners who want to integrate their open-systems applicationswith IBM-supported Ultrium hardware. The reference contains informationabout the application programming interfaces (APIs) for each of the varioussupported operating-system environments.

    v IBM Encryption Key Manager component for the Java platform Quick Start Guide(GA76-0420) gets you started with a basic configuration for encryption on LTO 4tape drives.

    v IBM Encryption Key Manager component for the Java platform Introduction, Planning,and User's Guide(GA76-0418) contains information to help you install, configure,and use the IBM Encryption Key Manager component for the Java platform.

    v IBM Tivoli Key Lifecycle Manager V1.0 (English) publications may be

    downloaded from the following Web site: http://www.ibm.com/software/tivoli/library.

    IBM Tivoli Key Lifecycle Manager Quick Start Guide (GI11-8738)

    IBM Tivoli Key Lifecycle Manager Installation and Configuration Guide(SC23-9977)

    v The IBM Publications Center:http://www.ibm.com/shop/publications/orderThePublications Center is a worldwide central repository for IBM productpublications and marketing material with a catalog of 70,000 items. Extensivesearch facilities are provided. Payment options for orders are via credit card (in

    Copyright IBM Corp. 2007, 2012 xxix

    http://www.ibm.com/storage/http://www.ibm.com/storage/http://www.ibm.com/software/tivoli/libraryhttp://www.ibm.com/software/tivoli/libraryhttp://www.ibm.com/software/tivoli/libraryhttp://www.ibm.com/shop/publications/orderhttp://www.ibm.com/shop/publications/orderhttp://www.ibm.com/software/tivoli/libraryhttp://www.ibm.com/software/tivoli/libraryhttp://www.ibm.com/storage/
  • 7/23/2019 TS3200

    32/374

    the U.S.) or customer number for 20 countries. A large number of publicationsare available online in various file formats, and they can all be downloaded byall countries, free of charge.

    xxx TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

  • 7/23/2019 TS3200

    33/374

    Chapter 1. Product Description

    The IBM System Storage TS3100 Tape Library (2U library) and the IBM SystemStorage TS3200 Tape Library (4U library) provide compact, high-capacity, low-cost

    solutions for simple, unattended data backup. The 4U library houses up to 48 tapecartridges (or 45 and an elective 3-slot I/O Station) in a compact 4U form factorwith easy access to cartridges via four removable magazines. The 2U libraryhouses up to 24 tape cartridges (or 23 and an elective 1-slot I/O Station) in acompact 2U form factor with easy access to cartridges via two removablemagazines.

    The sixth generation of the Ultrium series of products is available with interfacesto suit your needs: a Fibre Channel interface (FC), or Serial Attached SCSI interface(SAS).

    Front Panel

    Table 1-1 on page 1-2below contains front panel descriptions for both the 2Ulibrary inFigure 1-1and the 4U library inFigure 1-2.

    a77ug

    006

    3 1 2 3

    44 578 6

    Figure 1-1. Front panel of a 2U library

    a77ug

    115

    1 2 33

    4 57 68

    Figure 1-2. Front panel of a 4U library

    Copyright IBM Corp. 2007, 2012 1-1

    |

    |

    |

  • 7/23/2019 TS3200

    34/374

    Table 1-1. 2U library and 4U library front panel descriptions

    Number Item Description

    1 Power button Pressing this button powers ON the library. Pressing and holding this button for 4seconds will power OFF the unit (soft power down). No power switch or button canbe found on the back panel of the library.

    2 Front panel

    LEDs (left toright)

    v Ready/Activity(Green LED) - It is illuminated any time the unit is powered ON and

    able to function. It should blink whenever there is library or drive activity, or whenthe library is in the process of powering up.

    v Clean Drive (Amber LED) - It is illuminated when the drive needs to be cleaned.The LED will be turned OFF after the drive is cleaned successfully.

    v Attention (Amber LED) - It is illuminated when there has been a failure thatindicates a piece of media is bad, marginal, or invalid. It will be cleared when allinvalid cartridges have been exported from the library. The amber LED may also belit because a power supply or a power supply fan is failing, or a drive sled isdefective, missing, or has been replaced by a different drive type.

    v Error (Amber LED) - It is illuminated when there is an unrecoverable library ordrive failure. A message is displayed at the same time on the Operator Control Paneldisplay.

    3 Cartridgemagazines

    v

    The 2U library contains two cartridge magazines. The left magazine can hold up to 12 cartridges (or 11 data cartridges and the

    elective 1-slot I/O Station.)

    The right magazine can hold up to 12 cartridges.

    v The 4U library contains four cartridge magazines.

    The upper left magazine can hold up to 12 cartridges.

    The lower left magazine can hold up to 12 cartridges (or 9 data cartridges and theelective 3-slot I/O Station.)

    The upper right magazine can hold up to 12 cartridges.

    The lower right magazine can hold up to 12 cartridges.

    4 Air vents These vents draw cooler air into the library enclosure and allow warm air to escape,which helps keep the library at a normal operating temperature.

    5 Control keysv UP (+)- The upper left button is used to scroll upward through menu items.

    v DOWN (-)- The lower left button is used to scroll downward through menu items.

    v CANCEL (X) - The upper right button is used to cancel a user action and return tothe previous menu screen.

    v SELECT- The lower right button is used to display a sub-menu or force an accessoraction.

    6 Machine type,Model number,

    and SerialNumber label

    The machine type, model number and serial number of the library are located on thislabel. This serial number is the number that links the library to your warranty.

    7 Operator

    Control Paneldisplay

    This component is a 128 X 64 monochrome graphic display.

    8 I/O Station The Input/Output (I/O) Station is used to import and export cartridges into and outof the library.

    v The 2U library has an elective 1-slot I/O Station.

    v The 4U library has an elective 3-slot I/O Station.

    1-2 TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

  • 7/23/2019 TS3200

    35/374

    Rear Panel

    1 2 3

    a77

    ug

    300

    Figure 1-3. Rear panel (drive sled only) of a half high Fibre Channel drive

    a77

    ug

    233

    1 3 4

    12

    567810

    2

    11 9

    Figure 1-4. Rear panel of a 4U library with full high Fibre Channel drive and half high SAS drives.

    a77ug

    234

    1 3 4

    5789

    2

    1011

    12

    6

    Figure 1-5. Rear panel of a 2U library with a full high dual port SAS drive

    Chapter 1. Product Description 1-3

    |

    ||

  • 7/23/2019 TS3200

    36/374

    Table 1-2. 2U library and 4U library rear panel descriptions

    Number Item Description

    1 Power connector(s) Both libraries require a 110/220 volt AC power connection.

    v The 2U library has one power supply.

    v The 4U library has a minimum of one power supply, but has the capability ofadding a redundant power supply.

    2 Host interfaceconnectors

    The library has one or more of the following host interface connectors on the drivesled:

    v Fibre Channel connector

    v SFF-8088 mini-SAS connector

    3 Tape drive sled This library supports the Ultrium 3, 4, 5, and 6 tape drive. The tape drive in thelibrary is packaged in a container called a drive sled. Drive sleds come in full highor half high configurations. The drive sled is a customer replaceable unit (CRU),and is hot-pluggable, which is designed for easy removal and replacement.

    4 Shipping lock andlabel storage

    location

    The shipping lock, which secures the accessor during shipping, and associatedlabel are stored on the rear panel of the library for future use. SeeRemoving andStoring the Shipping Lock on page 4-4.Note: The shipping lock must be removed before powering ON the library to

    allow the accessor to function properly.5 USB port Used to save/restore library configuration information on a USB device.

    6 Library ControlBoard (LCC) LED

    An LED showing the status of the Library Control Board.

    LED flashing (1 flash per second) - normal operation

    7 Serial port This port is used to communicate serially with the library using an RJ-11 connector.For use by IBM Service Personnel.

    8 Ethernet port This port is used to connect the library to a network.

    LED

    v 10/100 Link

    Description: Green: Link Integrity

    Flashing: Network synchronization/negotiation

    Steady (On): Good connection

    Off: No connection between NIC and hub

    v Activity

    Description: Amber: Port traffic indicator

    Flashing: Network traffic present

    Steady (On): Heavy network traffic

    Off: No traffic

    9 Tape drive LED This LED indicates the current status of the drive. When the LED is green, itindicates normal drive activity.

    10 Machine type,

    Model number, andSerial Numberpull-out label

    The machine type, model number and serial number of the library are located on

    this pull-out label. This serial number is the number that links the library to yourwarranty.

    11 Fan vents These vents allow air to escape from the power supply and tape drive sled.

    12 ESD label The Electrostatic Discharge label is a reminder that some of the components of thislibrary are susceptible to electrostatic discharge. SeeElectrostatic Discharge onpage 10-1.

    1-4 TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

    |

  • 7/23/2019 TS3200

    37/374

    Bar Code Reader

    The bar code reader is an integral part of the library accessor. The bar code readerprovides inventory feedback to the host application, Operator Control Paneldisplay, and Web User Interface by reading cartridge bar code labels. The librarystores the customized inventory data in memory.

    Library firmware supports a 6 or 8 character volume serial number (VOLSER) onthe bar code label on the tape cartridge.

    Encryption

    The LTO Ultrium 4, 5, and 6 Tape Drive supports host Application ManagedEncryption (AME), Library Managed Encryption (LME), and System ManagedEncryption (SME), using T10 encryption methods, for SAS and Fibre Channeldrives only. Data encryption is supported with LTO Ultrium 4, Ultrium 5, andUltrium 6 Data Cartridges only. Encryption is also supported with library firmwareversion 4.0 or higher.

    The encryption enabled drive contains the necessary hardware and firmware toencrypt and decrypt host tape application data. Encryption policy and encryptionkeys are provided by the host application or host server. A drive digital certificateis installed at manufacturing time. Each drive receives a unique serial number andcertificate. The T10 application may validate each drive instance by checking thedrive's digital certificate.

    The LTO Ultrium 6 encryption environment is complex and requires knowledgebeyond that of product trained Service Support Representatives (SSRs). TheEncryption function on tape drives (desktop, stand alone and within libraries) isconfigured and managed by the customer. In some instances, SSRs are required toenable encryption at a hardware level when service access or service passwordcontrolled access is required. Customer setup support is by Field Technical Sales

    Support (FTSS), customer documentation, and software support for encryptionsoftware problems. Customer 'how to' support is also provided via support linecontract.

    The library firmware should always allow the user to select "None" or "ApplicationManaged Encryption" from the Web User Interface, as long as there is at least oneencryption capable drive in the logical library. If a valid Transparent Encryptionlicense key has been previously entered, "System Managed Encryption" or "LibraryManaged Encryption" can be selected. The factory default is "None."

    Note: The optional Transparent Encryption Key feature enabling System ManagedEncryption and Library Managed Encryption is not available on TS3200 andTS3100 models purchased through High Volume (HVEC) channels.

    Note: All encryption settings should be configured or re-verified in the drive afterany library or drive reset. This is because a new drive may have been addedor an existing drive may have been swapped with another drive.

    For more details, see the IBM Tape Device Drivers documentation, and the IBMLTO Ultrium Tape Drive SCSI Reference documentation. See "Related Publications"in the Preface.

    Chapter 1. Product Description 1-5

    |

    |

    |

    |

    |

    |

    |

    |

    |

    |

    |

    |

  • 7/23/2019 TS3200

    38/374

    Supported Internet Protocols

    The library supports the following Internet protocols:

    v IPv4

    v IPv6

    To learn more about Internet protocols, visit http://www.iana.org/.

    SNMP Messaging

    Occasionally, the library may encounter a situation that you want to know about,such as an open magazine or a fault that causes the library to stop. The libraryprovides a standard TCP/IP protocol called Simple Network Management Protocol(SNMP) to send alerts about conditions (such as need for operator intervention)over a TCP/IP LAN network to an SNMP monitoring station. These alerts arecalled SNMP traps. Using the information supplied in each SNMP trap, themonitoring station (together with customer-supplied software) can alert operationspersonnel of possible problems or operator interventions that occur.

    SNMP TrapsSNMP traps are alerts or status messages that can be collected, monitored andused to proactively manage attached libraries using SNMP protocol with the hostserver(s). In summary, each trap provides the following information:

    v Product Identificationsuch as product name, description, manufacturer, modelnumber, firmware level, and the URL that the trap is designated for.

    v Product Status such as the severity of the trap, status (current and previous) andthe time the trap occurred.

    v Library State (physical device status) such as identification and status of devicesthat are monitored. In the case of the library, it would include enclosure, powersupply, controller, magazine status, drive count, cartridge slot count, and I/Ostation count. Also included would be certain library statistics, and whereappropriate, the fault FSC (fault symptom code) including the severity anddescription of that fault.

    v Drive Status such as the identification of each drive in the library, firmwarelevel, serial number and other address and status information.

    v Trap Definitions such as library status change, open magazine, I/O accessed,hard fault information, drive cleaning requests, excessive retries and libraryreturning to normal operations. For additional information, refer to Appendix G."SNMP Status MIB Variables and Traps" on page G-1.

    v SNMP MIBs: The library's Management Information Base (MIB) contains unitsof information that specifically describe an aspect of the system, such as thesystem name, hardware number or communications configuration. Status anderror data is also gathered by MIBs and sent to one or more IP addressesdefined during the SNMP configuration operation. Download the SNMP MIBfile for this library from http://www.ibm.com/storage/support.

    1-6 TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

    http://www.iana.org/http://www.ibm.com/storage/supporthttp://www.ibm.com/storage/supporthttp://www.ibm.com/storage/supporthttp://www.iana.org/
  • 7/23/2019 TS3200

    39/374

    Maximum Library Storage Capacity and Data Transfer Rate

    Maximum library storage capacity and maximum data transfer rates are as follows:

    Table 1-3. Tape drive model and host interface type

    Tape Drive Model Host Interface

    Ultrium 6 Full High and Half

    High drivesv

    8 Gb/s Fibre Channel - single portv 6 Gb/s Serial Attached SCSI (SAS) - dual port

    Ultrium 5 Full High and HalfHigh drives

    v 8 Gb/s Fibre Channel - single port

    v 6 Gb/s Serial Attached SCSI (SAS) - dual port

    Ultrium 4 Full High drivesv 4 Gb/s Fibre Channel - single port

    v 3 Gb/s Serial Attached SCSI (SAS) - dual port

    Ultrium 4 Half High V2 drivesv 8Gb/s Fibre Channel - single port

    v 6GB/s Serial Attached SCSI (SAS) - dual port

    Ultrium 4 Half High drivesv 3 Gb/s SAS - single port

    Ultrium 3 Full High drivesv Ultra160 SCSI LVD (depending on drive; single-ended (SE) is not

    recommended as it will severely degrade performance)

    v 4 Gb/s Fibre Channel - single port

    Ultrium 3 Half High V2 drivesv 6GB/s Serial Attached SCSI (SAS) - dual port

    Ultrium 3 Half High drivesv Ultra 160 SCSI LVD (depending on drive; single-ended (SE) is not

    recommended as it will severely degrade performance)

    v 3 Gb/s SAS - single port

    Table 1-4. Library storage capacity and data transfer rate

    Characteristic 2U Library Specification 4U Library Specification

    Maximum storage capacity -

    Ultrium 6 Data Cartridgesv 24 data cartridges

    v Native: 60 TB

    v Compressed: 150 TB (2.5:1compression)

    v 48 data cartridges

    v Native: 120 TB

    v Compressed: 300 TB (2.5:1compression)

    Maximum storage capacity -Ultrium 5 Data Cartridges

    v 24 data cartridges

    v Native: 36 TB

    v Compressed: 72 TB (2:1 compression)

    v 48 data cartridges

    v Native: 72 TB

    v Compressed: 144 TB (2:1compression)

    Maximum storage capacity -Ultrium 4 Data Cartridges

    v 24 data cartridges

    v Native: 19.2 TB

    v Compressed: 38.4 TB (2:1compression)

    v 48 data cartridges

    v Native: 38.4 TB

    v Compressed: 75.2 TB (2:1compression)

    Maximum storage capacity -Ultrium 3 Data Cartridges

    v 24 data cartridges

    v Native: 9.6 TB

    v Compressed: 19.2 TB (2:1compression)

    v 48 data cartridges

    v Native: 19.2 TB

    v Compressed: 38.4 TB (2:1compression)

    Chapter 1. Product Description 1-7

    |

    |

    |

    |

    |

    |

    |

    |

    |

    |

    |

    |

    |

    |

  • 7/23/2019 TS3200

    40/374

    Table 1-4. Library storage capacity and data transfer rate (continued)

    Characteristic 2U Library Specification 4U Library Specification

    Sustained native data transferrate

    LTO 3 HH: 60 MBs,

    LTO 3 HH V2: 80 MBs

    LTO 3 FH: 80 MBs

    LTO 4 HH and FH: 120 MBs

    LTO 5 HH and FH: 140 MBs

    LTO 6: 160 MBs

    Ultrium Tape Drives

    This library supports the Ultrium 3, 4, 5, and 6 Tape Drives. Each tape drive in thelibrary is packaged in a container called a drive sled. The drive sled is a customerreplaceable unit (CRU), and is designed for quick removal and replacement in thelibrary.

    The Ultrium 6 Full High Tape Drives support Serial Attached SCSI (SAS) or FibreChannel interfaces. It features two SFF-8088 SAS connectors, or one LC FibreChannel connector. The Ultrium 6 Half High Tape Drive supports two SASSFF-8088 connectors, or one LC Fibre Channel connector. The SFF-8088 SASconnectors on the Ultrium 6 tape drives are compatible with SAS-1 or SAS-2cables.

    The Ultrium 5 Full High Tape Drives support Serial Attached SCSI (SAS) or FibreChannel interfaces. It features two SFF-8088 SAS connectors, or one LC FibreChannel connector. The Ultrium 5 Half High Tape Drive supports two SASSFF-8088 connectors, or one LC Fibre Channel connector. The SFF-8088 SAS

    connectors on the Ultrium 5 tape drives are compatible with SAS-1 or SAS-2cables.

    The Ultrium 4 Full High Tape Drives support LVD Ultra160, Serial Attached SCSI(SAS) , or Fibre Channel interfaces. It features two SFF-8088 SAS connectors, or oneLC Fibre Channel connector. The Ultrium 4 Half High Tape Drive (Feature Code8147) supports one SAS SFF-8088 connector. The Ultrium 4 Half High V2 TapeDrives (Feature Codes 8148 and 8149) support two SFF-8088 SAS connectors, orone LC Fibre Channel connector. The SFF-8088 SAS connectors on the Ultrium 4tape drives are compatible with SAS-1 cables.

    The Ultrium 3 Full High Tape Drive supports LVD Ultra160, or Fibre Channelinterfaces. It features two HD68 connectors or one LC Fibre Channel connector. The

    Ultrium 3 Half High Drive (Feature Codes 8046 and 8047) supports one SASSFF-8088 connector or two HD68 SCSI connectors. The Ultrium 3 Half High V2Tape Drive (Feature Code 8049) supports two SFF-8088 SAS connectors. TheSFF-8088 SAS connectors on the Ultrium 3 tape drives are compatible with SAS-1cables.

    1-8 TS3100 Tape Library and TS3200 Tape Library Setup, Operator, and Service Guide

    |

    |

    |

    |

    |

    |

    |

    |

  • 7/23/2019 TS3200

    41/374

    Note: Ultrium 3 and 4 SCSI, SAS, and Fibre Channel drives are allowed in thesame physical and logical library.

    Speed MatchingTo improve system performance, the Ultrium 3, Ultrium 4, Ultrium 5, and Ultrium6 Tape Drives use a technique called speed matching to dynamically adjust its native(uncompressed) data rate to the slower data rate of the attached server.

    a

    77ug

    008

    Figure 1-6. Library drive sled without ESD springs (SCSI sled shown)

    a77

    ug

    202

    1

    Figure 1-7. Library drive sled with ESD springs [1] (SAS sled shown)

    Chapter 1. Product Description 1-9

    |

    |

  • 7/23/2019 TS3200

    42/374

    Channel CalibrationThe channel calibration feature of the Ultrium 3, Ultrium 4, Ultrium 5, and Ultrium6 Tape Drives customizes each read/write data channel for optimum performance.The customization enables compensation for variations in the recording channeltransfer function, media characteristics, and read/write head characteristics.

    Power ManagementThe Ultrium 3, Ultrium 4, Ultrium 5, and Ultrium 6 Tape Drive's powermanagement function controls the drive's