If you can't read please download the document
Upload
lyhuong
View
223
Download
4
Embed Size (px)
Citation preview
DIRECT PERFORMANCE, FLUSH MESOOPTICS LENS4000K, 2200 LM/4FT
Project:
Spec Type:
Catalog No: 39S1LAGQ
Qty
Line Notes:
TRUGROOVE STANDALONEPERFORMANCE LED
Ordering guide
Product Type
39S1
TruGrooveStandalonePerformance LED
Source
L
LL LED
Color *
A
AA 4000KBB 3500KCC 3000K
Lumens *
G
EE 3000 lm/4ftGG 2200 lm/4ftKK 1500 lm/4ft
Optics
Q
QQ Flush LensRR Regressed Lens
Housing
S
SS StandardCC Chicago Plenum
Ceiling / Trim
11 T-Grid44 Drywall Trim33 Drywall Trimless
Run Length
02022'04044'08088'
Wiring
11 1 cct33 1 cct w/ EM cct55 1 cct w/ BP77 1 cct w/ Dimming
Voltage
11 120V22 277V33 347V
Driver
EE Standard
* Nominal values Consult website for complete list of standard wiring options Driver details on following pages
Mounting Hardware
Recessed Mount TypeMount TypeConsult separate mounting spec sheet for mount type options
Endcaps - Factory Installed Integrated Controls Please indicate with check mark.
Response Daylight Single Zone (DS)
2014 Koninklijke Philips N.V. (Royal Philips). All rights reserved.Specifications are subject to change without notice.www.philips.com/luminaires
39S1LAGQ.pdf 03.14 page 1 of 4
TRUGROOVE STANDALONEPERFORMANCE LED
Direct Performance, Flush MesoOptics Lens
Photometry
180
135
90
45
0
45
90
135
0% Up / 100% Down
04590
1000 cd
Total Output 2187 lm
Efficacy 78.4 lm/W
CCT 4039K
CRI 84
R9 17
Distribution 0% Up / 100% Down
Spacing Criteria (0/90/180) 1.41/1.75/NA
Meets RP-1-04 recommendations for VDT-Normal spaces
Values per 4ft unit
Fixture photometry has beenconducted by an NVLAP accreditedtesting laboratory in accordance withIESNA LM-79:2008
Lumen maintenance of the LEDs hasbeen tested by the manufacturer inaccordance with IESNA LM-80:2008
IES files for this and otherphotometric options can bedownloaded online atwww.ledalite.com
Horizontal AngleVerticalAngle 0 22.5 45 67.5 90
ZonalLumens
0 667 667 667 667 667 05 668 664 673 678 677 6515 661 673 717 750 762 20425 648 691 792 884 917 36435 611 674 813 910 940 48845 466 500 582 637 651 43955 295 319 339 358 365 30565 180 191 198 210 216 19975 88 91 96 103 103 10385 16 16 19 20 20 2390 0 0 0 0 0 095 0 0 0 0 0 0105 0 0 0 0 0 0115 0 0 0 0 0 0125 0 0 0 0 0 0135 0 0 0 0 0 0145 0 0 0 0 0 0155 0 0 0 0 0 0165 0 0 0 0 0 0175 0 0 0 0 0 0180 0 0 0 0 0 0
Candela DistributionCeiling: 80 70 50 0
RCRWall: 70 50 30 10 70 50 30 50 30 10 0
0 119 119 119 119 116 116 116 111 111 111 1001 110 105 102 98 107 103 100 99 96 93 862 101 93 87 81 98 91 85 88 83 78 733 92 82 75 68 90 81 74 78 72 67 624 85 73 65 58 82 72 64 69 63 57 545 78 66 57 51 76 65 56 62 55 50 476 72 59 51 44 70 58 50 56 49 44 417 67 54 45 39 65 53 45 51 44 39 368 62 49 41 35 61 48 40 47 40 35 329 58 45 37 31 57 44 37 43 36 31 2910 54 41 33 28 53 41 33 40 33 28 26
Coefficients of Utilization (%)
Horizontal AngleVerticalAngle 0 45 90
55 5644 6497 699365 4671 5156 560575 3722 4088 439385 1993 2355 2537
Avg. Luminance (cd/m2)
Electrical Specifications
Input VoltageInput Voltage 120V120V 277V277V
Input PowerInput Power 27.9W 27.9W
Input CurrentInput Current 0.237A 0.115A
Power FactorPower Factor 0.983
Total Harm. DistortionTotal Harm. Distortion 16.5%
Tested values contact technical support for rated values.Off-state power zero unless certain controls are specified.
2014 Koninklijke Philips N.V. (Royal Philips). All rights reserved.Specifications are subject to change without notice.www.philips.com/luminaires
39S1LAGQ.pdf 03.14 page 2 of 4
TRUGROOVE STANDALONEPERFORMANCE LED
Modules & Runs
TruGroove Standalone LED nominal housing lengthsTruGroove Standalone LED nominal housing lengths
2ft, 4ft, 8ft
Flush lens trimless versions can be installed in either the wall or ceiling.
Refer to module size details below for actual dimensions e.g. trim. T-grid units fit within a standard 2' grid.To specify continuous runs, refer to TruGroove Continuous data sheets.
Module Dimensions
2014 Koninklijke Philips N.V. (Royal Philips). All rights reserved.Specifications are subject to change without notice.www.philips.com/luminaires
39S1LAGQ.pdf 03.14 page 3 of 4
TRUGROOVE STANDALONEPERFORMANCE LEDOptions and Details
Trim Views HousingDie-formed 20 gauge cold-rolled steel. Multiple upper wireentrances available for continuous row mounting of fixtures.
WeightMaximum 3.5lb/ft.
Optical SystemPerformance version: White light emitted from the LED sources isinternally reflected and laterally redirected by a biconvex lens. Light isthen reflected by Miro Silver panels and exits through the opticallens assembly. This assembly contains acrylic extrusion profiles toretain a layer of MesoOptics film, creating both an uninterruptedcontinuum of light and an optical batwing distribution.
Definition version: Light passes through a diffuse white acrylic lens todeliver a highly uniform luminous continuum.
Standard DriverDimming: 0-10V, 5-100%. Output is Class 2 rated.
Lumen MaintenanceAt an ambient temperature of 25C in non-insulated contactapplications, the LED lumen maintenance expectation for eachlumen package is:K: L80 (12k) 71,000 hrsG: L80 (12k) 68,000 hrsE: L80 (12k) 54,000 hrs
MountingMounting brackets on housing sides support T-Grid installation. 1/16 diameter aircraft cable with self-locking, tamper-resistant,miniature cable gripper provides vertical adjustment for drywall.Aircraft cable, crimp and gripper independently tested to meetstringent safety requirements.
JointsSelf-aligning joining system with hands-free pre-joining wire access.
ElectricalFactory pre-wired to section ends with quick-wire connectors.
ApprovalsCertified to UL, CSA and IES standards. Insulation Contact (IC)rated.
FinishExtruded aluminum trim and die-cast endplates coated withelectrostatically applied and thermally cured polyester powder coatpaint finish.
EnvironmentRated for dry or damp locations in operating ambient temperatures0-40C (32-104F).
Due to continuing product improvements, Philips Ledalite reserves the right to change the specifications without notice.
2014 Koninklijke Philips N.V. (Royal Philips). All rights reserved.Specifications are subject to change without notice.www.philips.com/luminaires
39S1LAGQ.pdf 03.14 page 4 of 4
Philips Lighting Company200 Franklin Square DriveSomerset, NJ 08873Phone: 855-486-2216
TruGroove StandalonePerformance LEDOrdering guide
TruGroove StandalonePerformance LEDPhotometryCandela DistributionCoefficients of Utilization (%)Avg. Luminance (cd/m2)
Electrical Specifications
TruGroove StandalonePerformance LEDModules & RunsTruGroove Standalone LED nominal housing lengths
Module Dimensions
TruGroove StandalonePerformance LEDOptions and DetailsTrim ViewsHousingWeightOptical SystemStandard DriverLumen MaintenanceMountingJointsElectricalApprovalsFinishEnvironment