Upload
ramiz-rzaoglu
View
220
Download
0
Embed Size (px)
Citation preview
8/11/2019 Trouble Shooting - Case Analysis
1/26
2008, ZTE Corporation. All rights reserved. 1
Trouble Shooting - Case Analysis
Sun Changyu 1 537 7
8/11/2019 Trouble Shooting - Case Analysis
2/26
8/11/2019 Trouble Shooting - Case Analysis
3/26
8/11/2019 Trouble Shooting - Case Analysis
4/26
2006, ZTE Corporation. All rights reserved.
ZTE Proprietary & Con fidential
Presentation for WiMAX Network
4
OMC alarms as No WTRX detected and No WDPA detected
Reason:
1. OMC data configuration is well done.2. The cable connecting RRU and BBU is not qualified or destroyed.
3. The optical fiber connecting RRU and BBU is not well connected with the optical
connection ports at both ends.
4. The type of optical fiber is not matched to the type of optical connectional ports.
5. RRU software version is not matched to the software versions of BBU and OMC.
6. TX and RX ports of optical fiber are not correctly assembled at the factory (that is that
TX port is assembled at the fiber end where RX port should have been assembled).
7. RRU is not powered on.8. RRU hardware is problematic.
Measurement:
1. Make sure connection relationship between Segment and TRX is configured or not.
2. Check power supply of RRU and measure power feeder cable voltage to make sure it is
within the requested range. ( the voltage should be about -53V without load)
3. Make sure optical fiber and optical connection ports are qualified(refer to for the quality
checking process)
4. Update RRU software version to make it catered to the software versions of BBU and
OMC.
5. Power off ,and then power on all equipment at BS side to reset the system.
6. Take off RRU and test RRU hardware.
8/11/2019 Trouble Shooting - Case Analysis
5/26
2006, ZTE Corporation. All rights reserved.
ZTE Proprietary & Con fidential
Presentation for WiMAX Network
5
Abnormal WDPA VSWR
8/11/2019 Trouble Shooting - Case Analysis
6/26
2006, ZTE Corporation. All rights reserved.
ZTE Proprietary & Con fidential
Presentation for WiMAX Network
6
OMC Alarm-Abnormal WDPA VSWR and Closed WDPA Channel
8/11/2019 Trouble Shooting - Case Analysis
7/26 2006, ZTE Corporation. All rights reserved.
ZTE Proprietary & Con fidential
Presentation for WiMAX Network
7
Reason:
1. The antenna feeder cable of PA channel 0 is not well connected.(feeder cable broken, water soaking in)
2. Frequency range of RRU DL signal is out of RFE frequency
range.
Measurement:1. Make sure RRU central frequency is correctly configured
according to the requested frequency range written on RRU
equipment label.
2 Change feeder cable or redo the feeder cable waterproof disposal.
3 Reset RRU and the alarm would be disappeared, if notdisappeared, changed RRU
8/11/2019 Trouble Shooting - Case Analysis
8/26 2006, ZTE Corporation. All rights reserved.ZTE Proprietary & Con fidential
Presentation for WiMAX Network
8
Closed WDPA Channel 0/1
8/11/2019 Trouble Shooting - Case Analysis
9/26 2006, ZTE Corporation. All rights reserved.ZTE Proprietary & Con fidential
Presentation for WiMAX Network
9
OMC Alarm-Closed WDPA Channels at the same time
8/11/2019 Trouble Shooting - Case Analysis
10/26
8/11/2019 Trouble Shooting - Case Analysis
11/26 2006, ZTE Corporation. All rights reserved.ZTE Proprietary & Con fidential
Presentation for WiMAX Network
11
RRU Tx0/Tx1 auto calibration failure
8/11/2019 Trouble Shooting - Case Analysis
12/26 2006, ZTE Corporation. All rights reserved.ZTE Proprietary & Con fidential
Presentation for WiMAX Network
12
RRU Tx0/Tx1 auto calibration failure
Reason 1:WDPA is power-off with power amplifier disabled, auto calibration will fail.
8/11/2019 Trouble Shooting - Case Analysis
13/26 2006, ZTE Corporation. All rights reserved.ZTE Proprietary & Con fidential
Presentation for WiMAX Network
13
RRU Tx0/Tx1 auto calibration failure
Reason 2:
forward link is abnormal, RRU auto calibration will fail
8/11/2019 Trouble Shooting - Case Analysis
14/26 2006, ZTE Corporation. All rights reserved.ZTE Proprietary & Con fidential
Presentation for WiMAX Network
14
RRU Tx0/Tx1 auto calibration failure
Reason 3:
RRU auto calibration failure can also be caused by abnormal calibrationprocessing internally in RRU - a
8/11/2019 Trouble Shooting - Case Analysis
15/26 2006, ZTE Corporation. All rights reserved.ZTE Proprietary & Con fidential
Presentation for WiMAX Network
15
RRU Tx0/Tx1 auto calibration failure
Reason 4:
Caused by abnormal calibration processing internally in RRU-b
8/11/2019 Trouble Shooting - Case Analysis
16/26 2006, ZTE Corporation. All rights reserved.ZTE Proprietary & Con fidential
Presentation for WiMAX Network
16
Some RRU configurations Error
8/11/2019 Trouble Shooting - Case Analysis
17/26 2006, ZTE Corporation. All rights reserved.
ZTE Proprietary & Con fidential
Presentation for WiMAX Network
17
RRU Board Type Configuration Error
RRU can not detected from omc ,but can find one alarm The board type
is not consistent with that configured on OMC
R9100(2x4) R911048
WPTR TRWC_B
8/11/2019 Trouble Shooting - Case Analysis
18/26 2006, ZTE Corporation. All rights reserved.
ZTE Proprietary & Con fidential
Presentation for WiMAX Network
18
RRU Antenna Ability Parameter Checking Error
RRU antenna mode configured at OMC is beyond the actial antenna-supporting ability of the type of RRU in the system
R9100
WPTRR911048
WPTR TRWC_B
24 or 22 24 or 48
8/11/2019 Trouble Shooting - Case Analysis
19/26 2006, ZTE Corporation. All rights reserved.
ZTE Proprietary & Con fidential
Presentation for WiMAX Network
19
RRU Parameter Configuration Failure
RRU Radio Frequency Configuration is out of Range
8/11/2019 Trouble Shooting - Case Analysis
20/26
8/11/2019 Trouble Shooting - Case Analysis
21/26 2006, ZTE Corporation. All rights reserved.
ZTE Proprietary & Con fidential
Presentation for WiMAX Network
21
Case1: How to check the RRU working normal if no any alarm on OMC?
Spetrum scan 1: normal with some users on-line
8/11/2019 Trouble Shooting - Case Analysis
22/26 2006, ZTE Corporation. All rights reserved.
ZTE Proprietary & Con fidential
Presentation for WiMAX Network
22
Case1: How to check the RRU working normal if no any alarm on OMC?
Spetrum scan 2: abnormal with some outsides interference
8/11/2019 Trouble Shooting - Case Analysis
23/26
8/11/2019 Trouble Shooting - Case Analysis
24/26
8/11/2019 Trouble Shooting - Case Analysis
25/26
8/11/2019 Trouble Shooting - Case Analysis
26/26