TECHNICAL catalogueHeating Trench Fan coil VKN
2016_01_USA
37
The future of any heating systems is laying among solutions that work well with low temperature renewable sour-ces of heating energy, also by achieving a high level of system energy efficiency.
A solid technical background for this pro-duct – Fan Assisted Trench Heater type Turbo VKN5 has been created during a long term R&D process conducted to-gether with Warsaw Technical Univer-sity, Cracow Technical University, Lublin Technical University and Polish Scientific Academy, whereas its brand new desi-gn through innovative construction has achieved better hydraulic and heating characteristic.
During the process of optimization R&D, a high level heating emitter has been achieved, whereas it would raise an energy efficiency of the heat distribution throughout the building but also incre-asing an effectiveness of low tempera-ture heating systems since it has been working along with them.
Fan Assisted Trench Heater TURBO VKN5 has been design bearing in mind being suitable for spacious interiors having many glazed façades. Using a modern fan motor that will use low energy con-sumption feature and producing very low noise level would not distract any room occupants whilst precise and sim-plified control panel would enable easy and exact adjustment of desired tempe-
rature. Using an economical fan resulted with designing heating emitter producing more output with shorter adjustment reaction time. Additionally low thermal inertia and using advanced electronic control resulted an optional savings on running costs up to 20% in a heat season. Trench Heater Turbo VKN5 may be a per-fect solution for low supply temperature heating systems or high condensation wet installations, also is available in high supply pressure versions. Relatively low depth of trench required for such a he-ating emitter would allow to put trench heater in floor/ceiling space of any sto-rey. Evenly distributed heat in a room is one of many significant benefits of using trench heating.
TURBO VKN5
Trench Heater with 24V Fan TURBO VKN5
38
ENERGY SAVINGS
Big advantage of this type of trench heaters is their high wor-king dynamic, quick coping with any changes in room thermal conditions, even warm air distri-bution throughout a room and low running costs.
Fan assisted trench heater is a perfect match for low temperatu-re water installations and heating systems.
FUNCTIONALITY
Trench heating distributes he-ating in perfect and discrete man-ner inside spacious and elegant interiors that having usually large glass façades. The only visible ele-ment of trench heating is an ele-gant grille that is composed into the floor that covers trench and coil elements.
Easy access through taking off a grille would enable easy access for cleaning or maintenance of a trench heating.
COMFORT
Trench heating are the ones that among many types of heating emitters would react in the quic-kest way for any changes of any thermal requirements in a room. This quick adaptation capacity allows to avoid any room overhe-ating.
Trench heating that are placed along the outskirts of a building would create a natural air curtain that may separate warm and cold air and prevents ‘floating’ cold air at the low, floor base level.
Using trench heating allows to eliminate of the moisture conden-sation from the surface of glass façades.
DURABILITY
There are high quality materials being used for designing copper aluminum coil, that also warrants corrosion resistance but also pro-tection against low quality of wa-ter from the boiler.
Due to using a raw steel with hot dip zm coating our heating emit-ters are usually more corrosion resistant.
Benefits of fan assisted trench heatingTURBO VKN5
Fan Assisted Trench Heaters Tur-bo VKN5 have been equipped with noiseless and energy efficient fans. Such a solution ena-bled a design of exceptionally ef- fective heating emitter that may be suitable to use in every single room.
Low thermal inertia and using advanced electronic control re-sulted an optional savings on operating costs up to 20% in a heat season.
39
ww
w.v
eran
ocon
vect
or.co
.uk
The equipment of Verano heater
Construction of Verano heater
STANDARD equipment:• trench (casing) made of hot-dip galvanized steel sheet with zinc magnesium coating, powder painted in black RAL 9005,• copper and aluminium heat exchanger with air vent,• 24 V DC fan with EC motor,• fan cover,• connection space cover,• water connection 2xIT 3/4˝, • fixing anchors,• leveling brackets,
ADDITIONAL equipment:• trench (casing) painted in any RAL colour,• frame around the heater casing, L or F type made of natural aluminum, powder coated in RAL, anodized or can be done as wood imitation• aesthetic grille made of aluminum (natural, anodized or powder painted in any RAL color), natural wood (oak, ash, beech, merbau, jatoba) or stainless steel• installation cover to protect against damage during transport and installation
Fan coverAirflow targeting sheet
Heat exchanger (copper-aluminium)
Fixing anchorSupply and return connection for central heating
Additional hole
Holes for the connection pipes
Fan
Air ventHeat exchanger fixing element
Connection space cover
Trench (casing)
Leveling bracket
Grille
TURBO VKN5
40
DimensionsTURBO VKN5
Heaters are also available with a non standard/custom lenghts (NS)
Heaters height of 2.5 inch are only available with SS grille, other will increase heater high to 3 inch
4 .75
3.52.5
,3 (3.
3)
47.5
)35.
2.53,
3(3.
Order code VKN5-H/W/L - fin type - in mm
Trench height (H) 2-1/2 to 4-3/4 inch
Trench width (W) 9-27/32 to 13-3/4 inch
Trench lenght (L) 29-1/2 to 139-3/4 inch
10.79-27/32
14.713-3/4
10.79-27/32
10.79-27/32
14.713-3/4
14.713-3/4
41
TURBO VKN5
Any empty space in a ceiling/floor void may result louder work of fan motors of trench heating units. In order to avoid any lon-gitudinal deflection (deflection of trench casing borders) during concrete coating you should use some elements that will expand a trench casing. Inside Turbo VKN5 trench heating units there are leveling and mount brackets, that will also enable fitting trench casing into a floor.
Holders that would keep the coil tight during the transport, are secured by screws to the trench casing. Before any fitting work you should unscrew screws that hold heat exchanger frame and implicitly take off the fan from a trench. When trench casing is fitted you need to tighten screws.
In a trench casing there are four holes – two of them are put at the same height as mounting brackets of a heat exchanger, third hole is as a spare one (i.e. for any fit-ting in any connections or capillary etc.).
It is forbidden to lead any water connec-tions along the coil inside the trench ca-sing, as it may harm temperature float by limiting an air exchange inside a trench. Connections of coil have internal thread of
Installation manual
Concrete slab
Fixing anchor
Hard polystyrene
ConcreteFlooring
PE foil
Low expansion foam
GrilleDilatation e.g. cork
Frame e.g. type L
Leveling bracket
Leveling-fixing anchor
24V Fan Coil trench heating is assembled to keep coil room side and to keep fan motor on a window side. In order to avoid causing any heat loss through the floor space, trench casing should be thermo insulated from outside of the trench casing. When assembling fan assisted trench heating unit you should remember to provide proper acoustic insulation in a spa-ce created by a trench void and through all layers of a floor.
¾˝. It could be connected by straight or angled thermostatic valves. There should be free space remained (for any connections, valves etc.) for c.a. 7 inch. It is not possible to turn around the coil heat exchanger for 180° according to its instal- lation. As an alternative it is possible to manufacture, according to any demand a trench heater having right side (R) or left side (L) valve connection. The side of valve connection to the water installation sho-uld be specified once the specific trench heating is being ordered.
An example of assembly a fan assisted trench heater L≥76-3/4 inch (side view)
42
TURBO VKN5 The control options of Verano trench heater fan assisted type VKN5
Thermostatic valve must be installed on the supply pipe, and the return valve on the return pipe. The electric-thermal servo-motor is installed directly on the thermostatic valve. Servo-motor must be con-nected to the room controller via a two-wire cable. Room controller allows you to open and close the valve and control the fan speed.
matically turns on and off the fan when the room temperature drops below or goes up the set tempe-rature on the thermostat. The controller with a buil-t-in sensor measures the temperature in the room and maintains its value at the set-point by control-ling the 2-position servo-motor.
Type TURBO VKN5
VKN5-7,8/25/L-12VKN5-7,8/35/L-14VKN5-9/25/L-12VKN5-9/35/L-14
Number of fan 1 2 3 4 5 6 7 8
Number of fan motors 1 1 1 2 2 2 3 3
Fan voltage [VDC] 24 24 24 24 24 24 24 24
Maximum current [A] 0,35 0,45 0,60 0,90 1,05 1,20 1,55 1,65
Maximum power consumption of EC
fan [W]8,4 10,8 14,4 21,6 25,2 28,8 37,2 39,6
VKN5-12/25/L-12VKN5-12/35/L-14
Number of fan 1 2 3 4 5 6 7 8
Number of fan motors 1 1 1 2 2 2 3 3
Fan voltage [VDC] 24 24 24 24 24 24 24 24
Maximum current [A] 0,45 1,00 1,10 2,00 2,10 2,20 2,65 3,20
Maximum power consumption of EC
fan [W]10,8 24,0 26,4 48,0 50,4 52,8 63,6 76,8
Trench length [inch]
Adjusting the heaters is done automatically by using the room controller The system auto-
29-1/2 42-1/4 61 76-3/4 92-1/2 108-1/4 124 139-3/4
43
TURBO VKN5
29-1/2
42-1/4
61
76-3/4
92-1/2
108-1/4
124
139-3/4
44
TURBO VKN5
ON
1 2 3
Attention! Switch (from the opposite side of the controller) needs to be turned on position „1”
RDG 160 TG0
PE
G0G
G0 STP 63electro-thermal servo-motor
24V type VKN5+ red- blackwhite - stearing
M-01Fan
Fan
Room controller L
Q1
+24VGND
LNPE
L1
+24V REG GND REG GND +24V GND +24V GND+24V
L2 L3
FAN.REG.2
Z N GND +24V
Q2 Q3 Q4
Valve
24V type VKN5
VKN5 24V
M
Fan
Valve
M
M1~
GY
0-10V
G0
10A24VDC
max 1mAY50 Y10
max 1mAG
G
-
-
+
+
Electrical connection instruction
Wiring diagram for the RDG160T controller
Wiring diagram for the other controllers
Attention!
Electrical connections can be only done by appropriate licensed person and in compliance with electric standards.
Voltage can be turned on only after through checking of whole connection diagram.
It is prohibited to supply TURBO VKN5 directly from the main voltage of 120- 208V.
Name Description Net price
Room temperature controller RF10BWireless digital temperature controller 4in1, white,
Room temperature controller RF10CWireless digital temperature controller 4in1, black,
Room temperature controller RF20BWireless digital temperature controller 4in1, white,
Thermostatic head SH Diamant White Cat. No. 600100001
Schlösser thermostatic heads with connection thread
M30x1.5 cooperate with all Schlösser valves
as well as withother valves with inserts
M30x1.5 and closing dimension
11,5 mm
Thermostatic head SH Diamant Plus White-Chrome Cat. No. 600100011
Thermostatic head SH Brillant White–Chrome Cat. No. 600200001
Thermostatic head SH Brillant White Cat. No. 600200002
Thermostatic head SH Brillant Chrome Cat. No. 600200003
Thermostatic head SH Brillant Satin Cat. No. 600200004
Thermostatic head SH Brillant Steel Cat. No. 600200005
Thermostatic head SH Brillant Gold Cat. No. 600200007
Control devices for trench VK 15, wall-mounted and floor-mounted - wireless system
Thermostatic heads for VERANO Floor-mounted and LST Wall-mounted Convectors
Central strip L08 Wireless central strip to control 8 heating zones
L04 module Expansion Module for wireless central strip L08, 4 zones
Thermostatic head GM10 Wireless thermostatic head M30x1,5, MINI version
Network Repeater RE 10 ZigBee Repeater Network
Network Coordinator C010 ZigBee Network Coordinator
B30 Internet Gateway Internet Gateway
Programmable TRV GP60 Fully programmable thermostatic head
flush-mounted, 120 V
flush-mounted, 120 V
wall-mounted, 120 V
Wireless digital temperature controller 4in1, black, Room temperature controller RF20C
wall-mounted, 120 V
Name Description
Straight thermostatic valvetype Siemens VDN 215
Angular thermostatic valvetype Siemens VEN 215
Straight return valve type Siemens ADN15
Angular return valvetype Siemens AEN15
Straight thermostatic valvetype Schlösser 601200004
Angular thermostatic valvetype Schlösser 601200005
Straight return valvetype Schlösser 601300004
Angular return valvetype Schlösser 601300002
Thermal servo-motor type Siemens STA 73 or STA 73/00
Supply voltage 24 V AC/DC, 2-position control. STA73 with1 m connection cable, STA73/00 – need a separate cable
ASY23L…
Cable – type Siemens ASY23L…Connection cable for STA 73/00 control mode 0…10 V,
length of 2 m, 3 m and 5 m, 2-position control
Verano controller type VER-24B (White)The control mode 0 … 10V or ON / OFF (valve 24V).
Ability to work in heating or cooling mode.Operating modes: comfort, economical and security.
Verano controller type VER-24C (Black)The control mode 0 … 10V or ON / OFF (valve 24V).
Ability to work in heating or cooling mode.Operating modes: comfort, economical and security.
Room temperature controllertype Siemens RDG160T
Power supply 24 V AC control output 0…10 V DC, for fan with ECM (electronically commutated motor). Automatic or ma-
nual heating /cooling. Fan speed is activated
Rail Power Supply Z030-24VDC Input voltage 100-240V AC, Input frequency
50-60Hz, Output voltage 24V DC, Max output current 1,25A
Rail Power Supply Z060-24VDCInput voltage 100-240V AC, Input frequency
50-60Hz, Output voltage 24V DC, Max output current 2,5A
Rail Power Supply Z100-24VDC Input voltage 100-240V AC, Input frequency
50-60Hz, Output voltage 24V DC, Max output current 3,8A
Rail Power Supply Z120-24VDCInput voltage 100-240V AC, Input frequency
50-60Hz, Output voltage 24V DC, Max output current 5A
Rail Power Supply Z240-24VDCInput voltage 100-240V AC, Input frequency
50-60Hz, Output voltage 24V DC, Max output current 10A
Rail Power Supply Z480-24VDCInput voltage 100-240V AC, Input frequency
50-60Hz, Output voltage 24V DC, Max output current 20A
Control devices for VERANO Trench Heaters Fan Assisted type TURBO VKN5 and Climaconvectors type CVK2/CVKS and CVK4
Valve diameter 15 DN
Valve diameter 15 DN
Valve diameter 15 DN
Valve diameter 15 DN
Valve diameter 15 DN
Valve diameter 15 DN
Valve diameter 15 DN
Valve diameter 15 DN
Name Description
46
CONNECTIONS TYPE
Side connection to be choosen
Standard Right – P, optional Left – L
Fan from the window side standard
ACCESORIES TYPEroll-up/linear/modular
Aluminium frame type L or F
Assembly cover on request
VKN5-7.8/25/L-12
CONNECTIONS TYPE
Connection threads IT 3/4˝ one-sided
Side connection to be choosen
Standard Right – P, optional Left – L
Fan from the window side standard
ACCESORIES TYPEroll-up/linear/modular
Aluminium frame type L or F
Assembly cover on request
TURBO VKN5
Please remember:
Order code for heaters type TURBO VKN5:VKN5-H/W/L - fin type
where:H - Trench height [mm]W - Trench width [mm]L - Trench length [mm]
Please remember:
Order code for heaters type TURBO VKN5:VKN5-H/W/L - fin type
where:H - Trench height [mm]W - Trench width [mm]L - Trench length [mm]
Trench lenght (L)Lenght of the heat exchanger ribbed part (Lhe)
Lk
Trench lenght (L)Lenght of the heat exchanger ribbed part (Lhe)Lk
2.5 to 3 inch height
Heaters height of 2.5 inch are only available with a SS grille, other will increase heater height to 3 inch
1/2
2-1/
23 (
) 0.7
42
10.79.8
10.7
9.8
2
Grille H=3/4 inch
1/2
2-1/
23 (
) 0.7
L [inch]29-1/2 42-1/4 61 76-3/4 92-1/2 108-1/4 124 139-3/4Ts/Tr °F
The standard heat output does not include 15% for piping pick-up, according to DIN EN 442-2: 2013 for room air temperature Ti = 65°F 1° corresponds to the control voltage of 4,5V, 2° corresponds to the control volt 7V, 3° corresponds to the control voltage 10V.
The standard heat output does not include 15% for piping pick-up, according to DIN EN 442-2: 2013 for room air temperature Ti = 65°F 1° corresponds to the control voltage of 4,5V, 2° corresponds to the control volt 7V, 3° corresponds to the control voltage 10V.
CONSULT SOFTWARE AND MDL FOR OTHER CONDITIONS
1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3°180/160 2223 3427 4832 4146 6830 9002 6148 9462 13346 8293 12763 18004 10196 15686 22130 12296 18922 26693 14328 22048 31105 16241 24991 35252170/150160/140140/120110/90 719 1108 1565 1344 2066 2915 1991 3066 4324 2687 4133 5831 3301 5081 7168 3983 6128 8648 4641 7140 10076 5261 8095 11420
7-7/85-7/8
14-3/413-3/4
14-3
/413
-3/4
9
5-7/
8
Grille H=3/4 inch
L [inch]Ts/Tr °F 29-1/2 42-1/4 61 76-3/4 92-1/2 108-1/4 124 139-3/4
DIMENSIONS UNIT [inch]
Trench height (H) 2-1/2 (3)
Trench width (W) 9.8
Grille width (Wg) 10-3/4
Trench length (L) 29-1/2 ÷ 139-3/4
Fin type 12
VKN5-7.8/35/L-14 DIMENSIONS UNIT [inch]
Connection threads IT 3/4˝ one-sided
width (Wg) 13-3/4
Trench length (L) 29-1/2 ÷ 139-3/4
Fin type 12
Trench height (H) 2-1/2 (3)
Trench width (W) 14-3/4
Grille
Heaters height of 2.5 inch are only available with a SS grille, other will increase heater height to 3 inch
CONSULT SOFTWARE AND MDL FOR OTHER CONDITIONS
1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3°180/160 2905 4286 6605 5412 7986 12310 8027 11846 18253 10826 15979 24619 13305 19638 30263 16054 23689 36506 18707 27603 42542 24140 31286 48213170/150160/140140/120110/90 941 1388 2138 1753 2588 3986 2598 3836 5913 3509 5176 7976 4310 6359 9803 5200 7672 11826 6059 8941 13776 6868 10134 15617
47
CONNECTIONS TYPE
Connection threads IT 3/4˝ one-sided
Side connection to be choosen
Standard Right – P, optional Left – L
Fan from the window side standard
CONNECTIONS TYPE
Connection threads IT 3/4˝ one-sided
Side connection to be choosen
Standard Right – P, optional Left – L
Fan from the window side standard
ACCESORIES TYPE
Grille H=18 mm roll-up/linear/modular
Aluminium frame type L or F
Assembly cover on request
ACCESORIES TYPE
Grille H=18 mm roll-up/linear/modular
Aluminium frame type L or F
Assembly cover on request
VKN5-9/25/L-12
VKN5-9/35/L-14
TURBO VKN5
Trench lenght (L)Lenght of the heat exchanger ribbed part (Lhe)
Trench lenght (L)Lenght of the heat exchanger ribbed part (Lhe)Lk
Please remember:
Order code for heaters type TURBO VKN5:VKN5-H/W/L - fin type
where:H - Trench height [mm]W - Trench width [mm]L - Trench length [mm]
Please remember:
Order code for heaters type TURBO VKN5:VKN5-H/W/L - fin type
where:H - Trench height [mm]W - Trench width [mm]L - Trench length [mm]
10.79.8
3-1/2 inch height
3-1/
23/
4
1/2
42
DIMENSIONS UNIT [inch]Trench height (H) 3-1/2
Trench width (W) 9.8
Grille width (Wg) 10-3/4
Trench length (L) 29-1/2 ÷ 139-3/4
Fin type 12
Trench width (W) 14-3/4
Grille (Wg) 13-3/4
Trench length (L) 29-1/2 ÷ 139-3/4
Fin type 12
14-3/413-3/4
1/2
7-7/85-7/8
14-3
/413
-3/4
9
5-7/
8
10.7
9.8
Lk 9
2
Ts/Tr °F 29-1/2 42-1/4 61 76-3/4 92-1/2 108-1/4 124 139-3/4
Ts/Tr °F 29-1/2 42-1/4 61 76-3/4 92-1/2 108-1/4 124 139-3/4
L [inch]
L [inch]
The standard heat output does not include 15% for piping pick-up, according to DIN EN 442-2: 2013 for room air temperature Ti = 65°F 1° corresponds to the control voltage of 4,5V, 2° corresponds to the control volt 7V, 3° corresponds to the control voltage 10V.
The standard heat output does not include 15% for piping pick-up, according to DIN EN 442-2: 2013 for room air temperature Ti = 65°F 1° corresponds to the control voltage of 4,5V, 2° corresponds to the control volt 7V, 3° corresponds to the control voltage 10V.
3-1/
23/
4
Trench height (H) 3-1/2 DIMENSIONS UNIT [inch]
1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3°180/160 2424 3751 5272 4511 6987 9821 6694 10363 14560 9026 13977 19638 11096 17179 24139 13387 20725 29121 15600 24152 33935 16241 27371 38460170/150160/140140/120110/90 784 1214 1708 1463 2264 3181 2169 3355 4716 2922 4528 6359 3594 5565 7819 4337 6714 9432 5053 7822 10994 6261 8866 12456
CONSULT SOFTWARE AND MDL FOR OTHER CONDITIONS
1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3°180/160 3171 4695 7212 5909 8746 13432 8763 12971 19917 11819 17496 26860 14530 21503 33018 17523 25943 39831 20422 30232 4641623146 34263 52605170/150160/140140/120110/90 1026 1521 2336 1913 2834 4351 2837 4201 6452 3829 5667 8702 10693 6966 12900 5677 8402 15034 6615 9793 10076 7498 11099 17039
CONSULT SOFTWARE AND MDL FOR OTHER CONDITIONS
48
TURBO VKN5
CONNECTIONS TYPE
Connection threads IT 3/4˝ one-sided
Side connection to be choosen
Standard Right – P, optional Left – L
Fan from the window side standard
ACCESORIES TYPEroll-up/linear/modular
Aluminium frame type L or F
Assembly cover on request
VKN5-12/25/L-12
VKN5-12/35/L-14
CONNECTIONS TYPE
Connection threads IT 3/4˝ one-sided
Side connection to be choosen
Standard Right – P, optional Left – L
Fan from the window side standard
ACCESORIES TYPEroll-up/linear/modular
Aluminium frame type L or F
Assembly cover on request
10050
1812
0
12
Trench lenght (L)Lenght of the heat exchanger ribbed part (Lhe)Lk
Please remember:
Order code for heaters type TURBO VKN5:VKN5-H/W/L - fin type
where:H - Trench height [mm]W - Trench width [mm]L - Trench length [mm]
Please remember:
Order code for heaters type TURBO VKN5:VKN5-H/W/L - fin type
where:H - Trench height [mm]W - Trench width [mm]L - Trench length [mm]
DIMENSIONS UNIT [inch]Trench height (H) 4-3/4
Trench width (W) 9.8
Grille width (Wg) 10-3/4
Trench length (L) 29-1/2 ÷ 139-3/4
Fin type 12
4-3/4 inch height
10-3/49.8
4-3/
43/
4
1/2
Trench lenght (L)Lk Lenght of the heat exchanger ribbed part (Lhe) 9
2
Trench width (W) 14-3/4
Grille (Wg) 13-3/4
Trench length (L) 29-1/2 ÷ 139-3/4
Fin
Trench height (H) 4-3/4 DIMENSIONS UNIT [inch]
14-3/413-3/4
14-3
/4
13-3
/4
9
5-7/
8
7 - 7 / 85 - 7 / 8
L [inch]
Grille H=3/4 inch
Grille H=3/4 inch
L [inch]Ts/Tr °F 29-1/2 42-1/4 61 76-3/4 92-1/2 108-1/4 124 139-3/4
Ts/Tr °F 29-1/2 42-1/4 61 76-3/4 92-1/2 108-1/4 124 139-3/4
The standard heat output does not include 15% for piping pick-up, according to DIN EN 442-2: 2013 for room air temperature Ti = 65°F 1° corresponds to the control voltage of 4,5V, 2° corresponds to the control volt 7V, 3° corresponds to the control voltage 10V.
The standard heat output does not include 15% for piping pick-up, according to DIN EN 442-2: 2013 for room air temperature Ti = 65°F 1° corresponds to the control voltage of 4,5V, 2° corresponds to the control volt 7V, 3° corresponds to the control voltage 10V.
10.7
9.8
1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3°180/160 2660 4106 5749 4951 7652 10707 7338 11348 15880 9896 15307 21418 12167 18816 26328 14676 22700 31760 17104 26451 37008 19382 29976 41942170/150160/140140/120110/90 1773 1330 1862 3301 2479 3468 4893 3676 5146 6593 4958 6936 8109 6093 8528 9783 7352 10288 11403 8569 11986 12924 9708 13585
CONSULT SOFTWARE AND MDL FOR OTHER CONDITIONS
1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3° 1° 2° 3°180/160 3458 5146 7863 6441 9582 14649 9555 14209 21718 12886 19164 29294 15839 23559 36009 19106 28418 43442 22263 33117 50620 25233 37529 57372170/150160/140140/120110/90 1118 1667 2547 2087 3103 4743 3096 4603 7035 4174 6206 9490 5128 7631 11665 6189 9203 14073 7212 10728 16398 8174 12156 18585
51
TURBO VKN5How to choose the most efficient heater?
Correction factors for Verano heaters type TURBO VKN5 taking into account the type of grille.
GRILLE TYPE AIR FLOW CORRECTION FACTOR
Aluminium grille closed profile 61,6% 1,00
Aluminium grille I-beam profile 57,6 % 0,99
Wooden grille 52% 0,97
Modular grille 60,8% 1,00
Linear grille 58% 0,99
Stainless steel grille 61,2% 1,00
Water capacity [dm3]
H = 78, 90, 120 mm
W [mm]L [mm]
750 1150 1550 1950 2350 2750 3150 3550
250 0,14 0,26 0,38 0,51 0,63 0,74 0,88 0,99
350 0,29 0,52 0,75 1,02 1,25 1,48 1,75 1,99
52
TURBO VKN5 Pressure looses [Pa]
9
7
5
4
3
2
2
3
4
5
7
910000
1000
100
1
10
2
3
4
5
2
3
4
5
7
9
1000
100009
7
5
4
3
2
5
7
9
700200 300 400 6001008060403010 20
7
9
9
7
5
4
3
2
2
3
4
5
7
910000
1000
100
1
10
2
3
4
5
2
3
4
5
7
9
1000
100009
7
5
4
3
2
5
7
9
700200 300 400 6001008060403010 20
7
9
L=3550
L=1950L=1550
L=1150
L=750
L=3150L=2750L=2350
L=3550
L=1950L=1550
L=1150
L=750
L=3150L=2750L=2350
Water flow in kg/h
Pres
sure
dro
p in
Pa
Pres
sure
dro
p in
Pa
Water flow in kg/h
Width: 9-27/32 inch Width: 13-3/4inch
53
TURBO VKN5
Heater typeControl voltage
U[V]
Trench TURBO VKN5 lenght [mm]
VKN5-7,8/25/L-12VKN5-7,8/35/L-14VKN5-09/25/L-12VKN5-09/35/L-14
VKN5-12/25/L-12VKN5-12/35/L-14
2 - -- 22 22 22 23,8 23,8
4 25 25 25 28 28 28 29,8 29,8
6 32 31 31 34 34 34 36,1 35,8
8 38 38 38 41 41 41 42,8 42,8
10 44 44 44 47 47 47 48,8 48,8
Due to the low sound pressure levels compared to the background measurement - value <20 dB, which is out of the hearing values range, are not shown in the table.
Due to the low sound power levels compared to the background measurement - value <28dB, which is out of the he-aring values range, are not shown in the table.
Heater typeControl voltage
U[V]
Trench TURBO VKN5 lenght [mm]
VKN5-7,8/25/L-12VKN5-7,8/35/L-14VKN5-09/25/L-12VKN5-09/35/L-14
2 - - - - - - - -
4 29 - - 29 29 29 32 30,8
6 36 34 34 37 37 37 39,5 38,8
8 41 42 42 45 45 45 46,5 46,8
10 48 48 46 51 50,1 49 51,5 51,5
VKN5-12/25/L-12VKN5-12/35/L-14
2 - - - 30 30 30 31,8 31,8
4 33 33 33 36 36 36 37,8 37,8
6 40 39 39 42 42 42 44,1 43,8
8 46 46 46 49 49 49 50,8 50,8
10 52 52 52 55 55 55 56,8 56,8
Sound pressure level Lp (A) [dB]
Sound power level Lw (A) [dB]
29-1/2 42-1/4 61 76-3/4 92-1/2 108-1/4 124 139-3/4
29-1/2 42-1/4 61 76-3/4 92-1/2 108-1/4 124 139-3/4
2 - - - - - - - -
4 21 - - 21 21 21 24 22,8
6 28 26 26 29 29 29 31,5 30,88 33 34 34 37 37 37 38,5 38,8
10 40 40 38 43 42,1 41 43,5 43.5
54
TURBO VKN5
TURBO VKN5-7,8/25/L-12
0500
100015002000250030003500400045005000550060006500700075008000850090009500
100001050011000
2 3 4 5 6 7 8 9 10U [V]
Q [W]
0246810121416182022242628303234363840424446
Lp [dB]
Q dla 750 Q dla 1150 Q dla 1550 Q dla 1950 Q dla 2350 Q dla 2750 Q dla 3150 Q dla 3550Lp dla 750 Lp dla 1150 Lp dla 1550 Lp dla 1950 Lp dla 2350 Lp dla 2750 Lp dla 3150 Lp dla 3550
TURBO VKN5-7,8/35/L-14
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
10000
11000
12000
13000
14000
2 3 4 5 6 7 8 9 10U[V]
Q[W]
0246810121416182022242628303234363840424446
Lp[dB]
Q dla 750 Q dla 1150 Q dla 1550 Q dla 1950 Q dla 2350 Q dla 2750 Q dla 3150 Q dla 3550Lp dla 750 Lp dla 1150 Lp dla 1550 Lp dla 1950 Lp dla 2350 Lp dla 2750 Lp dla 3150 Lp dla 3550
Heat output and sound pressure
Heat output and sound pressure for Verano heaters type Turbo VKN5 depending on the control voltage for Ts / TR / Ti = 75/65/20°C
The charts show the changes of the heater output Q [W] and the sound pressure level Lp [dB] as a function of control voltage U [V] for the individual heaters TURBO VKN5.
Please note! Example of the calculation of the heater output and sound pressure (for TURBO VKN5 and CVK) for various values of the voltage is located on page 71
55
TURBO VKN5
TURBO VKN5-09/25/L-12
0500
100015002000250030003500400045005000550060006500700075008000850090009500
1000010500110001150012000
1 2 3 4 5 6 7 8 9U[V]
Q[W]
0
5
10
15
20
25
30
35
40
45Lp[dB]
Q dla 750 Q dla 1150 Q dla 1550 Q dla 1950 Q dla 2350 Q dla 2750 Q dla 3150 Q dla 3550
Lp dla 750 Lp dla 1150 Lp dla 1550 Lp dla 1950 Lp dla 2350 Lp dla 2750 Lp dla 3150 Lp dla 3550
TURBO VKN5-09/35/L-14
0100020003000400050006000700080009000
100001100012000130001400015000
2 3 4 5 6 7 8 9 10U[V]
Q[W]
0
5
10
15
20
25
30
35
40
45Lp[dB]
Q dla 750 Q dla 1150 Q dla 1550 Q dla 1950 Q dla 2350 Q dla 2750 Q dla 3150 Q dla 3550
Lp dla 750 Lp dla 1150 Lp dla 1550 Lp dla 1950 Lp dla 2350 Lp dla 2750 Lp dla 3150 Lp dla 3550
Heat output and sound pressure
56
TURBO VKN5 Heat output and sound pressure
TURBO VKN5-12/35/L-14
0100020003000400050006000700080009000
10000110001200013000140001500016000
2 3 4 5 6 7 8 9 10U[V]
Q[W]
0
5
10
15
20
25
30
35
40
45
50Lp[dB]
Q dla 750 Q dla 1150 Q dla 1550 Q dla 1950 Q dla 2350 Q dla 2750 Q dla 3150 Q dla 3550
Lp dla 750 Lp dla 1150 Lp dla 1550 Lp dla 1950 Lp dla 2350 Lp dla 2750 Lp dla 3150 Lp dla 3550
TURBO VKN5-12/25/L-12
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
10000
11000
12000
2 3 4 5 6 7 8 9 10U[V]
Q[W]
0
5
10
15
20
25
30
35
40
45
50Lp[dB]
Q dla 750 Q dla 1150 Q dla 1550 Q dla 1950 Q dla 2350 Q dla 2750 Q dla 3150 Q dla 3550
Lp dla 750 Lp dla 1150 Lp dla 1550 Lp dla 1950 Lp dla 2350 Lp dla 2750 Lp dla 3150 Lp dla 3550
57
Total lenght of the trench (Lt)
Lenght of the trench heater (L)
Tota
l len
ght o
f the
tren
ch (L
t)
Leng
ht o
f the
tren
ch h
eate
r (L)
Lenght of the trench heater (L)
Total lenght of the trench (Lt)Lenght of the trench heater (L)
Total lenght of the trench (Lt)Lenght of the trench heater (L)
Total lenght of the trench (Lt)Lenght of the trench heater (L)
Corner (empty trench)
Grille corner so. herringbone
Lenght of the trench heater (L)
Lenght of the trench heater (L)
The angle of 90˚
Custom angle
Curved
Bevels Indentation
ANGLED & CURVED
Internal radius (Ri)
External radius (Re)
The l
ength
of th
e exte
rnal
arc
B
H
W
VK 15 / TURBO VKN5
To heat the room of irregular shape, such as circle or semi-circle and at the same time not to disturb its aesthetics and harmony ideally product will be angled and curved heaters available with or without fan.
www.mdlsoln.com
By: MDL Solutions
2275 UPPER MIDDLE RD, EOAKVILLE, ONTARIO
CANADA L6H 203TEL: 289 799-3414;
EMAIL: [email protected]
MDL SOLUTIONSNATIONAL DISTRIBUTOR
CANADA/ USA
After completion the edition of the directory on the 21.01.2015, may have been some changes in the products listed in.The manufacturer reserves the right to make changes to the design, color and specification.
Illustrations may include optional accessories. Printing technology can affect the differences in the forward colors. Please contact MDL for the newest information of Verano products.
Technical catalogue 2016_01_USA