2/20
Private sectorsEnergy, Private utilities,Industry, Infrastructure
and Buildings
Our Products are type tested at ERDA, NABL (NationalAccreditation Board for Testing and CalibrationLaboratories) and approved by utilities.
Approvals
2
SOL U TION FOR ELEC TRICA
L M V
DI S TRIB U TION N
E T WORK
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
3/203
Public sectorsUtility market,
Governmentcompanies
Global Customer Base
Around 250 000 oil immersed distribution transformers with hermetic technology, installedworldwide.Private sectors
IndustryOmnium General Electric (Morocco),
Transfix India (India), Siddhivinayak
Aesthetics Pvt Ltd (India), Helical Auto Technology India Pvt Ltd(India), Arun Ginning & PressingInd. Corp (India), Indus Tower(India), Cahors Latino America(Uruguay), Ashish Agri Foods(India), Axayya Alloys Pvt Ltd(India), Freudenberg Filtration
Technologies India Pvt Ltd (India),Mannara Technologies (India),Mars Aluminium & Glazing (India),Kasper Builtmate Pvt Ltd (India)
BuildingsLouvre Museum (France) ,Hospitals (France, India, Chad),
Military Basis (France, Djibouti,Morocco), Stadium (France),Kolte-Patil Developers (Pune)
Infrastructure Tunnel (France, Sweden), Ports(France, Morocco), Irrigationplants (UAE, Mali, Burkina Faso),
Area of mining (Iran)
Energy Private UtilitiesWind farm (France) ,Photovoltaic farm (France) ,Hydroelectric station (France)
Why choose Transfix India Distribution Transformers? Energy ef cient products Advance / modern assembly
line and process State of the art internal
Quality standard
Indian Manufacturing, Frenchtechnology
Hermetic technology withnon gas cushion and maintenance free
On Time Delivery
Public sectors
ELECTRICITE DE FRANCE
(France), VATTENFAL (Sweden), EON (Sweden and Germany),
ONE (Morocco), SONELGAZ(Algeria), PPC (Greece), ESKOM (South Africa), ESB (Ireland), ADWEA (UAE), PPM (Nigeria), MSEDCL (India)
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
4/20
Norms & Specifications
4
Distribution Transformers
IS2026 (Part I to V): Indian Standards,Specification Of Power Transformers
IEC 60076 (Part 1 to 11): Power transformers.
Losses:
- Conformity to the star ratings as promotedby Bureau of Energy Efficiency (BEE).
- Conformity to Indian Standards.
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
5/20
Features
General Electrical CharacteristicsFrequency 50 Hz
Primary voltage11, 22 & 33 kV
Other voltage: on request.
Secondary voltage 433 V Other voltage: on request.
Couplings Dyn11
Tap Changers OCTC and OLTC
5
Transformers range from 50 kVA to 2500 kVA,with voltage classes from 11 kV to 33 kV,Oil-filled under vacuum, with hermetictechnology, non gas cushion.
Highly Energy Efficient with very low eddycurrent and hysteresis losses.
Advance - modern assembly line and process.
State of the art internal Quality standard.
Indian manufacturing.
Free breathing and hermetic variants available.
On Time Delivery.
Conformity to Indian Standards IS 2026 part 1 to 5 and BEErecommandations for losses.
Partial Discharge free.
Extremely Low Noise making design to comply with the local requirements.
Compact design and virtually Maintenance Free.
Mechanical characteristics, considering transportation and handling conditions in India. The designof the tank has been strengthened, the fixing of the active part inside the tank has been improved inorder to avoid any damage.
Tank painting performances: > 1000 hours salt spray test for outdoor conditions.
Reduced temperature rise (IEC 60076-2) and ambient temperature at 50C
Protection: DGPT2 (protection against gas, pressure and temperature fault)
Tap changer: OCTC (Off Circuit Tap Changer) and OLTC (On Load Tap Changer)
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
6/20
Distribution transformerwith OCTC
Rated Primary Voltage: 11 kV Rated Secondary voltage: 433 V
Rating(kVA)
Tap Changer Losses DimensionsTotal Weight
(kg)Off-Circuit Tap
Changer (%)
On load Tap
Changer (%)
No Load
(Watts)Load Imp (%) L (mm) W
(mm)H (mm)
63 +5 % to -5% -
On request
4.5 1030 830 1080 570
100 +5 % to -5% - 4.5 1070 830 1130 760
200 +5 % to -5% - 4.5 1290 910 1160 950
315 +5 % to -5% - 4.5 1550 950 1370 1680
400 +5 % to -5% - 4.5 1550 950 1370 1680
630 +5 % to -5% - 4.5 1590 1050 1455 2020
1000 +5 % to -5% +5% to -15% 5 2750 1895 1910 4100
1250 +5 % to -5% +5% to -15% 5 2760 1890 2010 4200
1600 +5 % to -5% +5% to -15% 6.25 2950 1920 2010 5400
Electrical Characteristics
6
HermeticTechnology(Non gascushion type)
DistributionTransformers 11 kV
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
7/20
Distribution transformer With LV side cable box
Distribution transformer With MV and LV side cable box
Dimensional Characteristics
L
L
W
W
H
H
7
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
8/20
Distribution transformerWith OCTCDistribution transformer
With OLTC
Electrical Characteristics
Hermetic Technology(Non gas cushion type)
Rated Primary Voltage: 22 kV Rated Secondary voltage: 433 V
Rating
(kVA)
Tap Changer Losses DimensionsTotal Weight
(kg)Off-Circuit TapChanger (%) On load TapChanger (%) No Load(Watts) Load Imp (%) L (mm) W (mm) H (mm)
63 +5 % to -5% -
On request
4.5 1030 830 1080 570
100 +5 % to -5% - 4.5 1070 830 1210 760
200 +5 % to -5% - 4.5 1290 910 1235 950
315 +5 % to -5% - 4.5 1550 950 1440 1680
400 +5 % to -5% - 4.5 1550 950 1440 1680
630 +5 % to -5% - 4.5 1590 1050 1530 2020
1000 +5 % to -5% +5% to -15% 5 2650 1860 2300 4000
1250 +5 % to -5% +5% to -15% 5 2740 1880 2400 4250
1600 +5 % to -5% +5% to -15% 6.25 2840 1900 2400 4600
2000 +5 % to -5% +5% to -15% Transformers range coming soon2500 +5 % to -5% +5% to -15% Transformers range coming soon
DistributionTransformers 22 kV
8
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
9/20
Dimensional Characteristics
Distribution transformer Without medium voltage cable box - With OCTC
Distribution transformer With medium voltage cable box - With OCTC
Distribution transformer With medium voltage cable box - With OLTC
L
L
L
W
W
W
H
H
H
9
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
10/20
Dimensional characteristics
Distribution transformer with OLTC and MV cable boxL W
H
10
Hermetic Technology(Non gas cushion type)
Electrical CharacteristicsRated Primary Voltage: 33 kV Rated Secondary voltage: 433 V
Rating(kVA)
Tap Changer Losses DimensionsTotal Weight
(kg)Off-Circuit TapChanger (%)
On load TapChanger (%)
No Load(Watts) Load Imp (%) L (mm) W (mm) H (mm)
1000 +5 % to -5% +5% to -15%
On request
5 2980 2130 2300 4600
1250 +5 % to -5% +5% to -15% 5 3080 2150 2400 50001600 +5 % to -5% +5% to -15% 6.25 3200 2170 2400 5300
2000 +5 % to -5% +5% to -15% 6.25 Transformers range coming soon
2500 +5 % to -5% +5% to -15% 6.25 Transformers range coming soon
Distribution Transformers33 kV
Distribution transformer
with OLTC
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
11/2011
ENERGY EFFICIENTTRANSFORMERS
DISTRIBUTION TRANSFORMERS
WITH HERMETIC TECHNOLOGYNON GAS CUSHION
& FREE BREATHING
Electricity is essential to people: the Government of India puts a lotof efforts into developing infrastructures which are necessary forconnecting energy to people.
This is the reason why Groupe CAHORS proposes a full range ofdistribution transformers with the following specificities, in order tomeet the growing demand:
- Hermetic without gas cushion
- Free breathing
- Low losses
With its over 40 years long experience in French technologystransformers manufacturing, Groupe CAHORS is the perfect partner tomeet the needs of the most discerning clients.
Recently introduced in India, our transformers comply with IndianStandards, in accordance with energy saving defined by the guide lineof BEE (Bureau of Energy Efficiency, Government of India)
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
12/2012
Maximum Permissible Transformer LossLevels for the Indian BEE Star Classification:for three phase liquid-insulated transformers.
Rating 1 star 2 star 3 star 4 star 5 star
kVA MaxLossesat 50%(Watts)
MaxLosses
at 100%(Watts)
MaxLossesat 50%(Watts)
MaxLosses
at 100%(Watts)
MaxLossesat 50%(Watts)
MaxLosses
at 100%(Watts)
MaxLossesat 50%(Watts)
MaxLosses
at 100%(Watts)
MaxLossesat 50%(Watts)
MaxLosses
at 100%(Watts)
16 200 555 165 520 150 480 135 440 120 400
25 290 785 235 740 210 695 185 655 160 615
63 490 1415 430 1335 380 1250 330 1170 280 1100
100 700 2020 610 1910 520 1800 440 1700 360 1600160 1000 2800 880 2550 770 2200 670 1950 570 1700
200 1130 3300 1010 3000 890 2700 780 2400 670 2100
Hermetic transformers, with non gas cushion& free breathing technology have been provenworldwide for many decades.
Groupe CAHORS provides STAR 3products which give full response toreduce the losses of electricity in thebene t of Utilities and also to savethe electricity consumption of EndUsers.
Transformers with hermetic technologydo not require any oil replacement tillthe end of the life of products. This providestremendous advantages by giving both savings inmaintenance cost and helping CO2 reduction in favor of anenvironment friendly approach. These products provide thebest TOC (Total Owning Cost) to the Users giving to themunmatched Return on Investment (ROI).
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
13/2013
All accessories required in conventional design to ensure safety like gas,pressure and temperature have been clubbed into one device DGPT2.
Product Standard
Accessories & Fittings
Accessories
PressureRelease Device
Off Load Tap Changer
On load Tap changer
Rating Plate
Cable Box forHV Bushing
Cable Box forLV Bushing
Lifting LugDGPT2
Jacking Pad Valve FlangeMarshalling box Earthing terminalRoller wheels
Oil Level Gauge
Oil / Winding Temperature
Indicator
HV / LV Bushing
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
14/20
Our manu fac tur ing fac i l i t i
es are fu l l y & sem i au toma
t ic,
con tro l led b y h ig h l y s k i l le
d super v isors .
We ha ve dep lo yed in terna l Q
ua l i t y Po l ic y Managemen t fo
r our
manu fac tur ing process. We
com b ine our h ig h qua l i t y pro
duc t ion
l ine w i t h t he d i l igen t ser v ice
o f wor k ers.
T he w ind ing as sem b l y are
a is dus t free & h ig h l y
comp l ian t to C lean l iness and Qua l i t
y S tandards .
Our qua l i t y componen t & m
anu fac tur ing to lerances
ensure par t ia l d isc harge free
& lo w edd y curren t losses
in t he produc ts.
O i l f i l l ing o f tan ks is done
in con tro l led en v ironmen t
under vacuum cond i t ion so t
ha t t he c harac ter is t ics &
t he qua l i t y o f du l y f i l tered p
rem ium o i l rema in per fec t
t hroug hou t t he l i fe t ime o f tr
ans formers. Hence t he
produc ts are ma in tenance
free.
Manu fac tur ing Process
M V / L V W ind ing
O i l f i l tra t ion
14
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
15/20
Our ad vance & au toma ted t
es t ing fac i l i t ie s are we l l e
qu ipped
w i t h SCADA S ys tem to au to- genera te
t he tes t repor ts .
Our a l l h ig h end & ca l i bra ted
tes t ing equ ipmen ts l i k e H ig h Vo l tage
Tes ter, M G se t, Res is tance M
e ter, Ra t io Me ter & Megger a
re used
for Rou t ine tes ts to be per fo
rmed in - house.
Our Produc ts are qua l i f ied fo
r t ype tes t a t Ind ian La bora t
or y
NABL & In terna t iona l La bo
ra tor y. We ensure t he tes t ing
&
measuremen t as per I S 20 26
& IE C -600 76.
Trans f i x Ind ia ensures t he
ON TIME de l i ve r y in
t he s treng t h t ha t:
Cen tra l i zed & s truc tured log
is t ics depar tmen t is
ma in ta ined w i t h ERP for in v
en tor y Managemen t.
Cr i t ica l Ra w ma ter ia l is s toc k
ed we l l in ad vance
to a vo id t he gap in produc t ion.
Tes t Fac i l i t ies
De l i ver y T ime and Log is t ics
Cus tomer Ser v ices
Groupe CAHOR S h ig h l y co
mpe ten t , we l l e xper ience
d
& we l l tr a ined team o f A f te
r Sa les peop le o f fers qu ic k &
e f fec t i ve tec hn ica l suppor t o
n Ins ta l la t ion, Comm iss ion in
g
& C harg ing o f Trans formers
on t he c l ien t s s i te.
15
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
16/2016
C O N N E C T IN G E NE R G Y AN D
P E O P L E
Connecting. Linking.
For over 100 years, that has been the driving force of GroupeCAHORS. Together, the men and women of CAHORS over the
world, work to help transport energies and facilitate access toinformation. They combine their skills and contribute technicaland innovative solutions that enable us to connect individualsand companies to the resources they need, such as electricity,information, water and gas.
CAHORS offers comprehensive solutions and equipment suited
to the specificities of electricity, water and gas distributionnetworks and communication networks all around the world.
Indus tr ia l s i tes
Wor ld w ide sa les presence
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
17/2017
TRANSFIX INDIATRANSFIX INDIA is a wholly owned subsidiary of Groupe CAHORSthat manufactures & markets Distribution Transformers,MV Switchgears and Compact Substations for both public andprivate distribution networks. TRANSFIX Mother Company is located in Toulon, France, and holds 4 subsidiaries in India,South Africa, China and Morocco.
Transfix India has its plant in Maharashtra,Location Ranjangaon MIDC, Pune
Size 5 acres, built up area 1,00,000 sq ft, office10,000 sq ft, shop floor 90,000 sq ft.
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
18/2018
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
19/2019
CONTACT DETAILSSERVICE SUPPORTContact - 02138 - 612 000sales.support @groupe-cahors.inwww.groupe-cahors.com
MANUFACTURING PLANTTransfix India PVT LTDE-90, MIDC, RanjangaonVillage: KaregaonTal: Shirur
Dist: Pune - 412 208Maharashtra - INDIAContact: 02138 612 000
7/25/2019 Transformer CAHORS Transfix-India-2014 BD
20/20
SALES OFFICE Transfix India PVT LTD
Office No 102, first floorAnand Emerald, A wingPlot No: 10-14, S. No 232/1+2Sakore NagarNew Airport RoadViman Nagar, Pune 411 014Maharashtra INDIAContact: 020 - 3026 1703Fax: 020 - 3026 1712sales support @ groupe-cahors in
MANUFACTURING PLANT Transfix India PVT LTD
E-90, MIDC, Ranjangaon Village: KaregaonTal: ShirurDist: Pune - 412 208Maharashtra INDIAContact: 02138 - 612 000
1 1 / 1 4 -
N o n
b i n d i n g
d o c u m e n
t