10
GRUNDFOS DATA BOOKLET TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D In-line circulator pumps 50 Hz Lenntech

TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D · TP Series 300 pumps 28 TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D 7. TP Series 300 pumps Fig. 12 TP Series 300 Technical data

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

  • GRUNDFOS DATA BOOKLET

    TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D

    In-line circulator pumps50 Hz

    Lenntech

  • TP Series 300 pumps

    28

    TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D

    7. TP Series 300 pumps

    Fig. 12 TP Series 300

    Technical data

    * At 120 to 150 °C, the maximum operating pressure is less than 23 bar.

    ConstructionGrundfos TP, TPD Series 300 pumps are single-stage, close-coupled pumps with in-line inlet and outlet ports of identical diameter. The pumps are fitted with a fan-cooled asynchronous motor. Motor and pump shafts are connected via a rigid sleeve coupling.Most TP Series 300 pumps are available as single-head, TP, and twin-head, TPD pumps.TP Series 300 pumps have PN 16 flanges or PN 25 flanges. The largest pumps have DN 500, PN 40 inlet flanges and DN 400, PN 40 outlet flanges and a maximum operating pressure of 25 bar.The pumps are fitted with an unbalanced or a balanced mechanical shaft seal.The pumps are of the top-pull-out design, that is you can remove the power head (motor, pump head and/or motor stool and impeller) for maintenance or service while the pump housing remains in the pipes. The pump housing is provided with a replaceable wear ring to ensure high pump efficiency for life.The twin-head pumps are designed with two parallel power heads. A non-return flap valve in the common outlet port is opened by the flow of the pumped liquid and prevents backflow of liquid into the idle pump head.As radial and axial forces are absorbed by the fixed bearing in the motor drive-end, the pump requires no bearing.The impeller is hydraulically balanced to minimise axial forces.TP, TPD Series 300 pumps are fitted with high-efficiency motors.TP Series 300 pumps with bronze impeller are suitable for pumping brine.

    Gr8

    259

    PN 16 version PN 25 version

    Flow rate [m3/h] Up to 2000 Up to 4500

    Head [m] Up to 93 Up to 140

    Liquid temperature [°C] -25 to +140 -40 to +150*

    Maximum operating pressure [bar] 16 25

    Direction of rotation Clockwise

  • TP S

    erie

    s 30

    0 pu

    mps

    TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D

    Materials

    Fig. 13 Sectional drawing of TP Series 300

    Material specification

    TP Series 300, PN 16

    TP Series 300, PN 25

    TP Series 300, DN 400, PN 25

    Mechanical shaft sealFor 16-bar versions, these types of unbalanced mechanical shaft seals are available as standard:• BAQE

    The BAQE shaft seal is a rubber bellows seal with carbon/silicon carbide seal faces and secondary seals of EPDM.

    • BQQEThe BQQE shaft seal is a rubber bellows seal with silicon carbide/silicon carbide seal faces and secondary seals of EPDM.

    For 25-bar versions, these types of balanced mechanical shaft seals are available as standard:• DAQF

    The DAQF shaft seal is a balanced O-ring seal with carbon/silicon carbide seal faces and secondary seals of FXM.

    • DQQEThe DQQE shaft seal is a balanced O-ring seal with silicon carbide/silicon carbide seal faces and secondary seals of EPDM.

    • DBUEThe DBUE shaft seal is a balanced O-ring seal with carbon/tungsten carbide seal faces and secondary seals of EPDM.

    For further information about common pumped liquids with recommended shaft seals, .Special shaft seals are available for partly conditioned water or other liquids containing abrasive or crystallising particles. .

    ConnectionsTP Series 300 pumps have PN 16 or PN 25 flanges. All dimensions are according to ISO 7005-2 or EN 1092-2.

    TM04

    958

    6 21

    15

    Pos. Component Material EN/DIN

    1 Pump housing Cast iron EN-GJL-250 EN-JL 1040

    2 Impeller Cast iron EN-GJL-200, bronze CuSn10EN-JL 10302.1093

    3 Stub shaftTwo-part stub shaftStainless steelStainless steel/steel

    1.43011.4301/1.0301

    4 Pump head/motor stool Cast iron EN-GJL-250 EN-JL 1040

    Secondary seals EPDM

    Rotating seal faceMetal-impregnated carbonSilicon carbide

    Stationary seat Silicon carbide

    5 Wear ring Bronze CuSn10/brass CuZn34Mn3Al2Fe1-C 2.1093

    Pos. Component Material EN/DIN

    1 Pump housing Ductile cast iron EN-GJS-400-18-LT EN-JS 1025

    2 Impeller Cast iron EN-GJL-200, bronze CuSn10EN-JL 10302.1093

    3 Stub shaftTwo-part stub shaftStainless steelStainless steel/steel

    1.43011.4301/1.0301

    4 Motor stool Cast iron EN-GJL-250 EN-JL 1040

    Secondary seals EPDMFXM

    Rotating seal faceMetal-impregnated carbonSilicon carbide

    Stationary seat Silicon carbide

    5 Wear ring Bronze CuSn10/brass CuZn34Mn3Al2Fe1-C 2.1093

    1

    2

    3

    4

    5

    Pos. Component Material EN/DIN

    1 Pump housing Ductile cast iron EN-GJS-400-18 (A-LT) EN-JS1020

    2 ImpellerDuctile cast iron EN-GJS-400 EN-JS1030Bronze CuSn10 2.1093

    3 Pump shaft Stainless steel 1.44364 Coupling Cast iron EN-GJL-250 EN-JL10405 Motor stool Cast iron EN-GJL-250 EN-JL1040

    Secondary seals EPDM rubberRotating seal face Resin-impregnated carbonStationary seat Tungsten carbide

  • TP Series 300 pumps

    30

    TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D

    Features and benefitsTP Series 300 pumps have these features and benefits:

    Optimised hydraulics for high efficiency– Reduced power consumption.

    High-efficiency motors– TP pumps are fitted with high-efficiency motors.

    High-efficiency motors offer reduced energy consumption. TP pumps are primarily fitted with motors that meet the legislative requirements of the EuP IE3 grade. TP pumps are also available with motors from 2.2 to 132 kW that meet the legislative requirements of the EuP IE4 grade. For further information, .

    Top-pull-out design– Easy dismantling in case of service.

    In-line design– Contrary to end-suction pumps, in-line pumps

    allow straight pipes and thus often reduced installation costs.

    Motor-pump shaft with sleeve coupling– Stable and quiet operation.– Easy dismantling in case of service.

    Hydraulically and mechanically balanced impeller– The impeller is hydraulically and mechanically

    balanced to increase the life of motor bearings and shaft seal.

    Surface treatmentTP Series 300 pumps are given the following surface treatment:

    Electrocoating includes:1. Alkaline cleaning.2. Pretreatment with zinc phosphate coating.3. Cathodic electrocoating, epoxy.4. Curing of paint film at 200-250 °C.For low-temperature applications at a high humidity, Grundfos offers TP pumps with extra surface treatment to avoid corrosion. These pumps are available on request.

    Pump type Electrocoating Spray paintingTP Series 300 from DN 32 to DN 350 x

    TP Series 300, DN 400 2x

  • Perf

    orm

    ance

    ran

    ge

    TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D

    Performance range, 2-pole, PN 6, 10, 16

    TM02

    755

    0 46

    17

    11.

    52

    34

    56

    81010

    1520

    3040

    5060

    8010

    010

    015

    020

    030

    040

    0

    Q [m

    ³/h]

    2345681015203040506080[m]

    H

    112

    34

    56

    78

    91010

    2030

    4050

    6070

    Q [l

    /s]

    2030405060708090100

    100

    200

    300

    400

    500

    600

    700

    800

    [kP

    a]p

    TP

    (D),

    TP

    E(D

    )P

    N 6

    /10/

    16, 2

    -pol

    e, 5

    0 H

    z

    32-8

    0

    32-5

    0

    25-9

    0

    25-5

    0

    25-8

    0

    125-

    310

    125-

    360

    65-

    170

    65-2

    10

    65-2

    5050-4

    20

    50-5

    40

    50-6

    30

    40-4

    3040

    -530

    40-6

    30

    100-

    25010

    0-31

    010

    0-36

    0

    100-

    390

    65-3

    40

    65-4

    10

    65-4

    60

    65-5

    5065-

    660

    65-7

    20

    65-9

    30

    50-1

    60

    50-1

    90

    50-2

    40

    50-2

    9050

    -360

    50-4

    30

    50-7

    10

    50-8

    30

    50-9

    00

    40-2

    40

    40-3

    0040-3

    60

    32-2

    00

    32-2

    50

    32-3

    20

    32-3

    80

    32-4

    60

    32-5

    80

    100-

    120

    80-1

    20

    65-1

    80

    65-1

    20

    65-6

    0

    50-1

    80

    50-1

    20

    50-6

    0

    40-2

    70

    40-2

    30

    40-1

    90

    40-1

    80

    40-1

    20 40-6

    0

    32-2

    30

    32-1

    80

    32-1

    50

    32-1

    20 32-6

    0

    40-5

    0

    40-9

    0

    80-1

    40

    80-1

    8080-2

    10

    80-2

    40

    80-2

    5080

    -3308

    0-40

    0

    80-5

    20

    80-5

    70

    80-7

    00

    100-

    16010

    0-20

    0

    100-

    240

    100-

    480

    32-9

    0

    12

  • Performance range

    TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D

    Performance range, 2-pole, PN 25

    TM06

    653

    3 42

    17

    2030

    4050

    6070

    8010

    015

    020

    030

    040

    050

    0

    Q [m

    ³/h]

    30405060708090100

    120

    140

    [m]

    H

    67

    89

    101020

    3040

    5060

    7080

    9010

    010

    0Q

    [l/s

    ]

    300

    400

    500

    600

    700

    800

    900

    1000

    1000

    [kP

    a]p

    TP

    PN

    25,

    2-p

    ole,

    50

    Hz

    100-

    530

    100-

    650

    100-

    800

    100-

    950

    100-

    1040

    100-

    1200

    100-

    1410

  • Perf

    orm

    ance

    ran

    ge

    TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D

    Performance range, 4-pole, PN 6, 10, 16

    TM02

    755

    1 42

    17

    23

    45

    68

    1012

    1520

    3040

    5060

    8010

    015

    020

    030

    040

    060

    010

    0015

    0020

    00

    Q [m

    ³/h]

    12345681010152030405060[m]

    H

    112

    34

    56

    78

    101020

    3040

    5060

    8010

    010

    020

    030

    0Q

    [l/s

    ]

    101020304050607080100

    100

    200

    300

    400

    500

    600

    700

    [kP

    a]p

    TP

    (D),

    TP

    E(D

    )P

    N 6

    /10/

    16, 4

    -pol

    e, 5

    0 H

    z

    350-

    280

    350-3

    20

    350-

    360

    350-

    420

    350-

    480

    350-

    530

    350-

    650

    350-

    780

    300-

    190

    300-

    220

    300-2

    5030

    0-290

    300-

    390

    300-

    420

    300-

    430

    300-

    500

    300-

    550

    150-

    150-

    155

    150-

    110

    150-

    70

    125-

    95

    125-8

    0

    125-

    125-

    400

    125-

    340

    125-

    300

    125-

    230

    125-

    190

    50-1

    40

    50-1

    2050

    -80

    40-1

    40

    40-1

    10

    200-

    160

    200-

    190

    200-

    200

    200-

    240

    200-

    290

    200-

    50

    200-

    70200

    -9020

    0-13

    0

    200-

    150

    150-

    450

    150-

    520

    150-

    660

    100-

    70

    100-

    90

    100-

    110

    200-

    660

    200-

    530

    200-

    590

    150-

    260

    150-

    280

    150-

    340

    150-

    390

    100-

    410

    100-

    370

    100-

    330

    100-

    250

    100-

    200

    100-

    170

    100-

    130

    80-3

    40

    80-2

    70

    80-2

    40

    80-1

    70 80-

    150

    80-1

    10

    80-9

    0

    80-7

    0

    65-1

    10

    65-1

    30

    65-1

    50

    65-1

    70

    65-2

    40

    65-9

    0

    50-1

    90

    50-2

    30

    50-9

    0

    40-1

    00

    32-1

    00

    32-1

    20

    32-8

    0

    100-

    60

    100-

    30

    80-6

    0

    80-3

    0

    65-6

    0

    65-3

    0

    50-6

    0

    50-3

    0

    40-9

    040

    -60 40

    -30

    32-6

    0

    32-4

    0

    32-3

    0

    125-

    130

    125-

    160

    150-

    130

    150-

    160

    150-

    220

    150-

    200

    150-

    250

    200-

    410

    200-

    320

    200-

    270

    200-

    470

    200-

    400

    200-

    360

    200-3

    30

    60

    170

    210

    0010

    00160 1060

  • Performance range

    TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D

    Performance range, 4-pole, PN 25

    TM02

    686

    9 42

    17

    2030

    4050

    6080

    100

    150

    200

    300

    400

    500

    600

    800

    1000

    1500

    2000

    3000

    5000

    Q [m

    ³/h]

    8101520304050607080[m]

    H

    67

    89

    101020

    3040

    5060

    7080

    100

    100

    200

    300

    400

    500

    600

    800

    Q [l

    /s]

    8090100

    100

    200

    300

    400

    500

    600

    700

    800

    [kP

    a]p

    TP

    PN

    25,

    4-p

    ole,

    50

    Hz

    200-

    410

    200-

    320

    200-

    660

    200-

    590

    200-

    530

    200-

    470

    200-

    400

    200-

    360

    200-

    270

    200-

    290

    200-

    240

    200-

    200

    200-

    160

    150-

    660

    150-

    520

    150-

    450

    150-

    390

    150-

    280

    150-

    260

    150-

    250

    150-

    220

    150-

    150-

    160

    150-

    130

    125-

    400

    125-

    340

    125-

    300

    125-

    230

    125-

    190

    125-

    150

    100-

    140

    100-

    200

    100-

    250

    100-

    330

    100-

    370

    100-

    410

    350-

    280

    350-3

    20

    350-

    360

    350-

    420

    350-

    480

    350-

    530

    350-

    650

    350-

    780

    300-

    190

    300-

    220

    300-

    250

    300-

    290

    300-

    390

    300-4

    20

    300-

    430

    300-

    500

    300-

    550

    400-

    720

    400-

    760

    400-

    670

    400-

    540

    400-

    510

    400-

    470

    200

  • Perf

    orm

    ance

    ran

    ge

    TP, TPD, TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D

    Performance range, 6-pole, PN 16

    Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 138.

    TM02

    876

    8 38

    14

    ����

    ���

    ����

    ���

    ���

    ���

    ���

    ��

    ����

    ��������������

    ��

    ��

    ������

    ���

    ��

    ������

    ����������������

    ���

    ���

    �����

    �����

    �!���"��� #�$"�����%

    �������

    �������

    �������

    ������

    ���������

    ��������

    ��������

    ��������

    ��������

    ��������

  • V7124417 1117ECM: 1222592 Th

    e na

    me

    Gru

    ndfo

    s, th

    e G

    rund

    fos

    logo

    , and

    be

    thin

    k in

    nova

    te a

    re re

    gist

    ered

    trad

    emar

    ks o

    wne

    d by

    Gru

    ndfo

    s H

    oldi

    ng A

    /S o

    r Gru

    ndfo

    s A

    /S, D

    enm

    ark.

    All

    right

    s re

    serv

    ed w

    orld

    wid

    e.©

    Cop

    yrig

    ht G

    rund

    fos

    Hol

    ding

    A/S

    [email protected] Tel. +31-152-610-900www.lenntech.com Fax. [email protected] Tel. +31-152-610-900www.lenntech.com Fax. +31-152-616-289

    Lenntech

    2. Performance rangePerformance range, TPE2, TPE3, PN 6, 10, 16Performance range, TPE2 D, TPE3 D, twin-head operation, PN 6, 10, 16Performance range, 2-pole, PN 6, 10, 16Performance range, 2-pole, PN 25Performance range, 4-pole, PN 6, 10, 16Performance range, 4-pole, PN 25Performance range, 6-pole, PN 16

    3. Product rangeProduct range, TPE2, TPE2 D, TPE3, TPE3 DProduct range, 2-pole, PN 6, 10, 16, 25Product range, 4-pole, PN 6, 10, 16, 25Product range, 6-pole, PN 16

    4. Operating conditionsSystem and test pressuresSound pressure levelAmbient temperatureInstallation altitude

    5. Pumped liquidsPumped liquidsLiquid temperatureList of pumped liquidsRecommended shaft seal for water- glycol mixture

    6. TP Series 100 and 200 pumpsTechnical dataConstructionMaterialsMechanical shaft sealConnectionsFeatures and benefits

    7. TP Series 300 pumpsTechnical dataConstructionMaterialsMechanical shaft sealConnectionsFeatures and benefits

    8. TPE Series 1000 pumpsTechnical dataConstructionApplicationsTPE, TPED pumps with extended performance rangeOperating modes of twin-head pumpsControl options

    9. TPE Series 2000 pumpsTechnical dataConstructionApplicationsTPE, TPED pumps with extended performance rangeOperating modes of twin-head pumpsControl options

    10. TPE2Technical dataConstructionMaterialsApplicationsMultipump systemControl options

    11. TPE3Technical dataConstructionMaterialsApplicationsMultipump systemControl options

    12. Overview of functions13. User interfaces for TPE pumpsControl panel for TPE2 and TPE Series 1000 pumps, 0.12 - 11 kW, 2- pole and 0.12 - 7.5 kW, 4-poleSetpoint setting

    Control panel for TPE Series 1000 pumps, 15-22 kW, 2-pole and 11 - 18.5 kW, 4-poleSetpoint settingSetting to maximum curve dutySetting to minimum curve dutyStart-stop of pump

    Control panel for TPE Series 2000 pumps, 15-22 kW, 2-pole and 11 - 18.5 kW, 4-poleAdvanced control panel for TPE3 and TPE Series 2000 pumps, 0.12 - 11 kW, 2-pole and 0.12 - 7.5 kW, 4- pole"Home" displayMenu overview for advanced control panel

    Grundfos GOCommunicationMenu overview for Grundfos GO

    Description of selected functions"Heat energy monitor""Setpoint""Operating mode""Set manual speed""Set user-defined speed""Control mode""Proportional-pressure setup""FLOWLIMIT""Automatic night setback""Sensor type""Analog inputs""Built-in Grundfos sensor""Pt100/1000 inputs""Digital inputs""Digital inputs/outputs""Signal relays 1 and 2" ("Relay outputs")"Analog output""Controller" ("Controller settings")"Operating range""External setpoint influence""Predefined setpoints""Temperature influence""Limit-exceeded function"Special functions"Service"CommunicationGeneral settings"Assist"

    Priority of settingsGrundfos EyeIndicator lights and signal relays

    14. Factory settings of E-pumps15. CommunicationCommunication with TPE2, TPE2 D, TPE3, TPE3 D, TPE, TPED pumps

    16. Speed regulation of TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D pumpsAffinity equations

    17. Control of pumps in parallelAlternation/standby functionPumps connected to Control MPCPumps connected to Control MPC Series 2000

    18. Grundfos CUETP pumps connected to Grundfos CUE, external frequency convertersFunctionsExternal communication

    19. Motor dataMotorsElectrical data, mains-operated motorsElectrical data, speed-controlled motors

    20. InstallationMechanical installationElectrical installationMains-operated motors

    21. MGE motorsMotors for TPE, TPE2 and TPE3 pumps fitted with 2-pole motors from 0.12 - 11 kW and 4-pole motors from 0.12 - 7.5 kWSingle-phase supply voltageThree-phase supply voltageInputs and outputsEMC, electromagnetic compatibilityEnclosure classInsulation classAmbient temperatureStandby power consumptionCable entriesSound pressure levelMotor protectionAdditional protectionMaximum number of starts and stopsWiring diagramsConnection terminals

    MGE motors, 11 to 18.5 kW, 4-pole, and 15 to 22 kW, 2-poleSupply voltageInput and outputEMC, electromagnetic compatibility to EN 61800-3Enclosure classInsulation classAmbient temperatureRelative humiditySound pressure levelMotor protectionAdditional protectionMaximum number of starts and stopsWiring diagram, 11-22 kWOther connections

    Identification of functional module

    22. Electromagnetic compatibility, EMCElectromagnetic compatibility and proper installationGeneral informationWhat is electromagnetic compatibility?EmissionImmunityE-pumps and electromagnetic compatibilityWhere to install E-pumps?What is meant by the first and the second environment?Electromagnetic compatibility and proper installationConnection of mains supply in MGE

    23. Flanges for TP pumpsFlange dimensions

    24. Curve chartsHow to read the curve chartsCurve conditions

    25. Performance curves and technical dataTPE2, TPE2 D, TPE3, TPE3 D, PN 6, 10, 16TP, TPD, TPE, TPED, 2-pole, PN 6, 10, 16, 25TP, TPD, TPE, TPED, 4-pole, PN 6, 10, 16, 25TP, TPD, TPE, TPED, 6-pole, PN 16

    26. Weights and shipping volumeTPE2, TPE2 D, TPE3, TPE3 D, PN 6, 10, 16TP, TPD, TPE, TPED, 2-pole, PN 6, 10, 16, 25TP, TPD, TPE, TPED, 4-pole, PN 6, 10, 16, 25TP, TPD, 6-pole, PN 6, 10, 16

    27. Minimum efficiency indexTPE2, TPE2 D, TPE3, TPE3 DTP, TPD, TPE, TPED, 2-pole, PN 6, 10, 16TP, TPD, TPE, TPED, 4-pole, PN 6, 10, 16TP, TPD, 6-pole, PN 16TP, PN 25

    28. AccessoriesUnions and valves, TP Series 100CounterflangesAdapter flanges for various port-to-port lengths

    Base platesBlanking flangesInsulating kitsKits for TPE2, TPE3 pumps

    SensorsFlow sensorsTemperature sensorsPressure sensors

    External Grundfos sensorsMP 204, advanced motor protectionControl MP 204PotentiometerGrundfos GOCIU communication interface unitsCIM communication interface modulesEMC filter

    29. Minimum inlet pressure - NPSHTPE2, TPE2 D, TPE3, TPE3 DTP, TPE, TPD, TPED, 2-pole, PN 6, 10, 16, 25TP, TPE, TPD, TPED, 4-pole, PN 6, 10, 16, 25TP, TPD, 6-pole, PN 16

    30. Key application dataOperating conditions

    31. Grundfos Product CenterBookmarks from TP-Performance.pdf2. Performance rangePerformance range, TPE2, TPE3, PN 6, 10, 16Performance range, TPE2 D, TPE3 D, twin-head operation, PN 6, 10, 16Performance range, 2-pole, PN 6, 10, 16Performance range, 2-pole, PN 25Performance range, 4-pole, PN 6, 10, 16Performance range, 4-pole, PN 25Performance range, 6-pole, PN 16

    3. Product rangeProduct range, TPE2, TPE2 D, TPE3, TPE3 DProduct range, 2-pole, PN 6, 10, 16, 25Product range, 4-pole, PN 6, 10, 16, 25Product range, 6-pole, PN 16

    4. Operating conditionsSystem and test pressuresSound pressure levelAmbient temperatureInstallation altitude

    5. Pumped liquidsPumped liquidsLiquid temperatureList of pumped liquidsRecommended shaft seal for water- glycol mixture

    6. TP Series 100 and 200 pumpsTechnical dataConstructionMaterialsMechanical shaft sealConnectionsFeatures and benefits

    7. TP Series 300 pumpsTechnical dataConstructionMaterialsMechanical shaft sealConnectionsFeatures and benefits

    8. TPE Series 1000 pumpsTechnical dataConstructionApplicationsTPE, TPED pumps with extended performance rangeOperating modes of twin-head pumpsControl options

    9. TPE Series 2000 pumpsTechnical dataConstructionApplicationsTPE, TPED pumps with extended performance rangeOperating modes of twin-head pumpsControl options

    10. TPE2Technical dataConstructionMaterialsApplicationsMultipump systemControl options

    11. TPE3Technical dataConstructionMaterialsApplicationsMultipump systemControl options

    12. Overview of functions13. User interfaces for TPE pumpsControl panel for TPE2 and TPE Series 1000 pumps, 0.12 - 11 kW, 2- pole and 0.12 - 7.5 kW, 4-poleSetpoint setting

    Control panel for TPE Series 1000 pumps, 15-22 kW, 2-pole and 11 - 18.5 kW, 4-poleSetpoint settingSetting to maximum curve dutySetting to minimum curve dutyStart-stop of pump

    Control panel for TPE Series 2000 pumps, 15-22 kW, 2-pole and 11 - 18.5 kW, 4-poleAdvanced control panel for TPE3 and TPE Series 2000 pumps, 0.12 - 11 kW, 2-pole and 0.12 - 7.5 kW, 4- pole"Home" displayMenu overview for advanced control panel

    Grundfos GOCommunicationMenu overview for Grundfos GO

    Description of selected functions"Heat energy monitor""Setpoint""Operating mode""Set manual speed""Set user-defined speed""Control mode""Proportional-pressure setup""FLOWLIMIT""Automatic night setback""Sensor type""Analog inputs""Built-in Grundfos sensor""Pt100/1000 inputs""Digital inputs""Digital inputs/outputs""Signal relays 1 and 2" ("Relay outputs")"Analog output""Controller" ("Controller settings")"Operating range""External setpoint influence""Predefined setpoints""Temperature influence""Limit-exceeded function"Special functions"Service"CommunicationGeneral settings"Assist"

    Priority of settingsGrundfos EyeIndicator lights and signal relays

    14. Factory settings of E-pumps15. CommunicationCommunication with TPE2, TPE2 D, TPE3, TPE3 D, TPE, TPED pumps

    16. Speed regulation of TPE, TPED, TPE2, TPE2 D, TPE3, TPE3 D pumpsAffinity equations

    17. Control of pumps in parallelAlternation/standby functionPumps connected to Control MPCPumps connected to Control MPC Series 2000

    18. Grundfos CUETP pumps connected to Grundfos CUE, external frequency convertersFunctionsExternal communication

    19. Motor dataMotorsElectrical data, mains-operated motorsElectrical data, speed-controlled motors

    20. InstallationMechanical installationElectrical installationMains-operated motors

    21. MGE motorsMotors for TPE, TPE2 and TPE3 pumps fitted with 2-pole motors from 0.12 - 11 kW and 4-pole motors from 0.12 - 7.5 kWSingle-phase supply voltageThree-phase supply voltageInputs and outputsEMC, electromagnetic compatibilityEnclosure classInsulation classAmbient temperatureStandby power consumptionCable entriesSound pressure levelMotor protectionAdditional protectionMaximum number of starts and stopsWiring diagramsConnection terminals

    MGE motors, 11 to 18.5 kW, 4-pole, and 15 to 22 kW, 2-poleSupply voltageInput and outputEMC, electromagnetic compatibility to EN 61800-3Enclosure classInsulation classAmbient temperatureRelative humiditySound pressure levelMotor protectionAdditional protectionMaximum number of starts and stopsWiring diagram, 11-22 kWOther connections

    Identification of functional module

    22. Electromagnetic compatibility, EMCElectromagnetic compatibility and proper installationGeneral informationWhat is electromagnetic compatibility?EmissionImmunityE-pumps and electromagnetic compatibilityWhere to install E-pumps?What is meant by the first and the second environment?Electromagnetic compatibility and proper installationConnection of mains supply in MGE

    23. Flanges for TP pumpsFlange dimensions

    24. Curve chartsHow to read the curve chartsCurve conditions

    25. Performance curves and technical dataTPE2, TPE2 D, TPE3, TPE3 D, PN 6, 10, 16TP, TPD, TPE, TPED, 2-pole, PN 6, 10, 16, 25TP, TPD, TPE, TPED, 4-pole, PN 6, 10, 16, 25TP, TPD, TPE, TPED, 6-pole, PN 16

    26. Weights and shipping volumeTPE2, TPE2 D, TPE3, TPE3 D, PN 6, 10, 16TP, TPD, TPE, TPED, 2-pole, PN 6, 10, 16, 25TP, TPD, TPE, TPED, 4-pole, PN 6, 10, 16, 25TP, TPD, 6-pole, PN 6, 10, 16

    27. Minimum efficiency indexTPE2, TPE2 D, TPE3, TPE3 DTP, TPD, TPE, TPED, 2-pole, PN 6, 10, 16TP, TPD, TPE, TPED, 4-pole, PN 6, 10, 16TP, TPD, 6-pole, PN 16TP, PN 25

    28. AccessoriesUnions and valves, TP Series 100CounterflangesAdapter flanges for various port-to-port lengths

    Base platesBlanking flangesInsulating kitsKits for TPE2, TPE3 pumps

    SensorsFlow sensorsTemperature sensorsPressure sensors

    External Grundfos sensorsMP 204, advanced motor protectionControl MP 204PotentiometerGrundfos GOCIU communication interface unitsCIM communication interface modulesEMC filter

    29. Minimum inlet pressure - NPSHTPE2, TPE2 D, TPE3, TPE3 DTP, TPE, TPD, TPED, 2-pole, PN 6, 10, 16, 25TP, TPE, TPD, TPED, 4-pole, PN 6, 10, 16, 25TP, TPD, 6-pole, PN 16

    30. Key application dataOperating conditions

    31. Grundfos Product Center