Occupancy Indicator Light Installation Cutout template (shown to scale) Ø .375" (10 mm) 2.375" (60 mm) 3.5625" (91 mm) 1. Tools required: Wire strippers, drill, tape measure, screwdriver, and drywall saw. 2. Wireless receiver and indicator light location: Locate switch inside restroom. Measure height to top of outlet box. 3. On opposite side of wall (outside of restroom), measure 3" (76 mm) above height of switch and make cutout for indicator light as shown in "Cutout Template" shown below. H H+3" (76 mm) Inside restroom Outside restroom 4. Receiver mounting: Wireless receiver mounts to electrical box using threaded connector as shown. External sensor in 12V DC out 0-10V- (Gray) 0-10V+ (Purple) Relay load (Red) Hot, 120-277 VAC (Black) Neutral (White) Orange, Gray, and Purple wires: Connect to indicator light connector Yellow wire capped, not used Red wire capped, not used 5. AC voltage wiring: Connect line voltage to BLACK wire and neutral to WHITE wire. RED and YELLOW wires are not used. Touchless Occupancy Indicator System Installation Guide for 601146, 601147, 601148, and 601153 PAGE 1 OF 3

Touchless Occupancy Indicator ystem - SloanLED

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Touchless Occupancy Indicator ystem - SloanLED

Occupancy Indicator Light Installation

Cutout template (shown to scale)

Ø .375" (10 mm)

2.375" (60 mm)

3.5625" (91 mm)

1. Tools required: Wire strippers, drill, tape measure, screwdriver, and drywall saw.

2. Wireless receiver and indicator light location: Locate switch inside restroom. Measure height to top of outlet box.

3. On opposite side of wall (outside of restroom), measure 3" (76 mm) above height of switch and make cutout for indicator light as shown in "Cutout Template" shown below.

HH+3"

(76 mm)

Inside restroom Outside restroom

4. Receiver mounting: Wireless receiver mounts to electrical box using threaded connector as shown.

External sensor in12V DC out0-10V- (Gray)0-10V+ (Purple)Relay load (Red)

Hot, 1

20-2

77 V

AC (B

lack)

Neut

ral (W

hite)

Orange, Gray, and Purple wires:

Connect to indicator light connector

Yellow wire capped, not used

Red wire capped, not used

5. AC voltage wiring: Connect line voltage to BLACK wire and neutral to WHITE wire. RED and YELLOW wires are not used.

Touchless Occupancy Indicator SystemInstallation Guide for 601146, 601147, 601148, and 601153

PAGE 1 OF 3

Page 2: Touchless Occupancy Indicator ystem - SloanLED

6. Indicator light installation: Feed cable of indicator light through cutout and into switch outlet box. Secure cable using included strain relief connector. Ensure drywall anchors are retracted far enough that wings will be able to pop open by turning screws counter-clockwise until anchor is at end of bolt. Insert light into cutout and turn bolts clockwise until anchors are securely held against back of drywall. Connect indicator light to wireless receiver via connectors.

1. Mount sensor in main area of restroom that will experience most traffic. Sensor should be mounted 6 - 8 ft (1.8 - 2.4 m) from ground.

2. Remove mounting plate from sensor by pressing release tab located on top of sensor. Hold mounting plate against wall and mark two (2) mounting points. Drill two holes with a 0.1875" (4.8 mm) bit and insert wall anchors. Insert first screw loosely and level mounting plate. Insert second screw and hand-tighten both screws.

3. System operation and setup: System has been programmed and sensors have been linked to the corresponding receivers. No setup is required. When sensor detects motion, indicator light will be illuminated RED. If no motion is detected for 45 seconds, light will change to GREEN.

Wireless sensor Installation – Wall mount

1. Remove mounting plate from sensor. Hold mounting plate in place on ceiling and use a pencil to lightly mark two (2) small dots for screw drill points. Drill two (2) holes with a 0.1875" (4.8 mm) drill bit and insert wall anchors. Insert first screw loosely and level mounting plate. Insert second screw and hand-tighten both screws.

2. Remove ceiling tile from desired installation location. Place mounting plate squarely on ceiling tile and insert wire bracket through two (2) holes in mounting plate. Feed wires through holes in ceiling tile. On front of ceiling tile, flatten wire bracket so it is snug against mounting plate. On back of ceiling tile, twist wires together to hold mounting plate securely.

3. Attach sensor to mounting plate, sliding sensor onto mounting plate until it snaps into place.

Wireless sensor Installation – Ceiling mount

Touchless Occupancy Indicator SystemInstallation Guide for 601146, 601147, 601148, and 601153

PAGE 2 OF 3

Page 3: Touchless Occupancy Indicator ystem - SloanLED

SloanLED Headquarters5725 Olivas Park Drive, Ventura, CA, USA888.747.4LED (888.747.4533) • [email protected]

SloanLED.com

SloanLED Europe b.v.Argonstraat 110, 2718 SN Zoetermeer, NL+31 88 12 44 900 • [email protected]

P/N 400403 Rev B 2020-10-21

Customer service and technical support

1. Set receiver into "Learn" mode by pressing LRN button for one (1) second. LRN LED begins toggling RED/GREEN indicating linking/unlinking mode is active.

2. Press "Menu" button on sensor once. LRN LED on receiver will display solid GREEN for four (4) seconds and indicator light will remain RED for four (4) seconds. Once indicator light begins to flash RED/GREEN again, wait 30 seconds or press LRN button for one (1) second to exit linking mode.

Multi-sensor Installations

LRN button

Menu button

601147 601153

Menu button

Set button

Set button

Touchless Occupancy Indicator SystemInstallation Guide for 601146, 601147, 601148, and 601153

PAGE 3 OF 3