To, Date 22.03.2018 Member Secretary Expert Appraisal Committee II Infrastructure Development, Coastal Regulation Zone, Building/Construction and Miscellaneous projects Ministry of Environment, Forest and Climate Change Indira Paryavaran Bhawan, 3rd Floor, Vayu Wing, Jor Bagh Road, Aliganj, New Delhi-110 003. Subject- Reply of queries raised towards Expansion of group housing at Khasra No. 1058m, 1726M/1, 1725M/2, 1724M, 1056M, 1058M, 1060/1 at Village Pasona Pargana, Loni, District-Ghaziabad, Uttar Pradesh by M/s Nipun Builders & Developers Pvt. Ltd, [F.No.21-130/2017-IA-III] Dear Sir, With reference to the above-referred subject and EAC Minutes of Meeting (MoM), dated November 30 th 2017, our point-wise reply of the queries are as follows:- S.No. Queries Reply 1 A certificate from the local body supplying water, specifying the total annual water availability with the local authority, the quantity of water already committed, the quantity of water allotted to the project under consideration and the balance water available. This should be specified separately for ground water and surface water sources, ensuring that there is no impact on other users. Water and sewer permission is attached as Annexure 1. 2 The Air Quality Index shall be calculated for base level air quality. The air Quality Index of the project site is 151. 3 A detailed report on compliance to ECBC norms. ECBC compliance report is attached as Annexure 2. 4 A detailed traffic management and traffic decongestion plan to ensure that the current level of service of the roads within a 05 kms radius of the project is maintained and improved upon after the implementation of the project. This plan should be based on cumulative impact of all development and increased habitation being carried out or proposed to be carried out by the project or other agencies in this 05 Kms radius of the site in different scenarios of space and time and the • Main road connecting to the project site is 75 m. • Separate entry exit will be provided Internal road width is 6 m wide. • Speed breakers proposed at the entry exit gate, at the entry/exit ramps of basements and at regular interval of the internal road. • Signage for speed limit restricted to 20 kmph will be displayed along the internal roads.

To, Date 22.03environmentclearance.nic.in/writereaddata/Online/... · 150mm RCC slab with 120mm Brick Bat Coba (U –Value = 1.65 W/m²·°C) 3. Glazing Glazing properties: Refer

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • To, Date 22.03.2018

    Member Secretary

    Expert Appraisal Committee II

    Infrastructure Development, Coastal Regulation Zone,

    Building/Construction and Miscellaneous projects

    Ministry of Environment, Forest and Climate Change

    Indira Paryavaran Bhawan,

    3rd Floor, Vayu Wing, Jor Bagh Road, Aliganj,

    New Delhi-110 003.

    Subject- Reply of queries raised towards Expansion of group housing at Khasra No. 1058m, 1726M/1,

    1725M/2, 1724M, 1056M, 1058M, 1060/1 at Village Pasona Pargana, Loni, District-Ghaziabad,

    Uttar Pradesh by M/s Nipun Builders & Developers Pvt. Ltd, [F.No.21-130/2017-IA-III]

    Dear Sir,

    With reference to the above-referred subject and EAC Minutes of Meeting (MoM), dated November 30th

    2017, our point-wise reply of the queries are as follows:-

    S.No. Queries Reply

    1 A certificate from the local body supplying

    water, specifying the total annual water

    availability with the local authority, the

    quantity of water already committed, the

    quantity of water allotted to the project under

    consideration and the balance water available.

    This should be specified separately for ground

    water and surface water sources, ensuring that

    there is no impact on other users.

    Water and sewer permission is attached as

    Annexure 1.

    2

    The Air Quality Index shall be calculated for

    base level air quality.

    The air Quality Index of the project site is

    151.

    3 A detailed report on compliance to ECBC

    norms.

    ECBC compliance report is attached as

    Annexure 2.

    4 A detailed traffic management and traffic

    decongestion plan to ensure that the current

    level of service of the roads within a 05 kms

    radius of the project is maintained and

    improved upon after the implementation of the

    project. This plan should be based on

    cumulative impact of all development and

    increased habitation being carried out or

    proposed to be carried out by the project or

    other agencies in this 05 Kms radius of the site

    in different scenarios of space and time and the

    • Main road connecting to the project site

    is 75 m.

    • Separate entry exit will be provided

    Internal road width is 6 m wide.

    • Speed breakers proposed at the entry

    exit gate, at the entry/exit ramps of

    basements and at regular interval of the

    internal road.

    • Signage for speed limit restricted to 20

    kmph will be displayed along the

    internal roads.

  • traffic management plan shall be duly validated

    and certified by the State Urban Development

    department and the P.W.D. and shall also have

    their consent to the implementation of

    components of the plan which involve the

    participation of these departments.

    • One way internal traffic movement is

    proposed.

    • Parking norm as per local regulation

    5 The permission of the CGWA for abstraction of

    ground water and for basement/excavation

    dewatering.

    This is an vertical expansion project so

    permission of CGWA for basement/

    excavation dewatering is not required.

    Without getting approval from CGWA,

    Ground water will not be extracted at any

    stage of the project.

    6 A certificate of adequacy of available power

    from the agency supplying power to the

    project along with the load allowed for the

    project.

    Power assurance letter is attached as

    Annexure 3.

    7 A certificate from the competent authority for

    discharging treated effluent/ untreated

    effluents into the Public sewer/

    disposal/drainage systems along with the final

    disposal point.

    The same is attached as Annexure 1.

    8 A certificate from the competent authority

    handling municipal solid wastes, indicating the

    existing civic capacities of handling and their

    adequacy to cater to the M.S.W. generated

    from project.

    Municipal solid waste will be handled by

    Ghaziabad Development authority

    We trust that you will find the above clarifications / replies in-line with your requirements and looking

    forward to get the environmental clearance for the project at the earliest.

  • ENERGY CONSERVATION AND BUILDING CODE

    Project : Nipun Saffron Valley, Group Housing Project

    Location : Village – Pasonda, Pargana - Loni, District- Ghaziabad, U.P

    Compliance: ECBC

    Date: 02.03.2018

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTD

    ENERGY CONSERVATION AND

    BUILDING CODE

  • Energy Simulation report has been compiled by Atmos Sustainable Solutions Pvt. Ltd. For located in

    Gurgaon, India. The scope of the project is 3 Residential Buildings.

    SOFTWARE SUMMARY

    The Energy simulation report contains results of energy analysis of the Proposed Buildings, To establish the

    building performance rating as per ECBC, energy modeling was carried out by using simulation software

    called Trane TRACE 700.

    The software is very well capable of simulating and analyzing on hourly basis.

    This Simulation study shows that the project performs better as compared to the ECBC benchmark for

    Energy Performance Index (Criteria 8). The proposed project shows 40.97% lower energy consumption than

    ECBC benchmark EPI.

    GRIHA COMPLIANCE

    MANDATORY

    - Compliance with Energy Conservation Building Code-2007 as per clause 14.1.1. (Mandatory)

    - Compliance with thermal comfort conditions as per National Building Code-2005/ASHRAE 55 – 2010.

    -Minimum 20% reduction below the benchmark for Energy Performance Index (EPI) as per ECBC. (2 Points)

    APPRAISAL

    As per ECBC Energy Performance Credit, Every 10% reduction in EPI of the building under a specified

    category shall fetch additional 2 points to a maximum of 8 points (50% reductions in EPI from the

    benchmark). (2-10 points)

    EXECUTIVE SUMMARY:

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTD

    ENERGY CONSERVATION AND

    BUILDING CODE

  • EXECUTIVE SUMMARY:ECBC compliance (8 points)

    Compliance with Energy Conservation Building Code-2007as per clause 14.1.1.

    (6 Points) Compliance with thermal comfort conditions as per National Building

    Code-2005/ASHRAE 55 – 2010. Reduction in 10% from benchmark for Energy

    Performance Index (EPI) as per clause 14.1.5 (2 Points)

    Credit points ( 2-8 Points)

    Every 10% reduction in EPI of the building shall fetch an additional 2 points to a

    maximum of 8 points.

    As per Energy Performance Index, following are the points for Energy

    Performance.

    Percentage Energy Performance Index Points

    10% reduction from benchmark (Mandatory) 2

    20% reduction from benchmark 3

    30% reduction from benchmark 5

    40% reduction from benchmark 7

    50% reduction from benchmark 10

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTD

    ENERGY CONSERVATION AND

    BUILDING CODE

  • PROJECT INFORMATION: Project IOCL Residential Colony

    Energy Simulation ECBC

    Total Simulated Area 52656 sq.m.

    Number of buildings and

    designation5(Residential)

    Type of building Residential

    Climate Composite

    Occupancy24 Hours occupancy for

    Residential

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTD

    ENERGY CONSERVATION AND

    BUILDING CODE

  • WEATHER:

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTD

    ENERGY CONSERVATION AND

    BUILDING CODE

  • ASSUMPTIONS:

    S. NO. MODEL

    INPUT

    PARAMETER

    S

    PROPOSED CASE

    1. Exterior Wall

    Construction200 mm AAC Block

    (U-Value = 0.67 W/m²·°C)

    2. Roof

    Construction

    150mm RCC slab with 120mm Brick Bat Coba

    (U – Value = 1.65 W/m²·°C)

    3. Glazing Glazing properties: Refer Material Glazing Sheet

    description.

    For Residential : U - factor: 3 W/m²·°C SHGC : 0.25

    4. Shading devices Shading Devices - As per design

    5. Wall Window

    RatioTower 1 – 28%

    Tower 1 – 30%

    Tower 1 – 27%

    6. Lighting Power

    Density

    [As per ECBC Standard]

    Living Spaces: 7.5 w/sq.m.

    Kitchen: 12.9 W/sq.m.

    Toilet : 1.5 W/sq.m.

    Corriodor : 4.32 W/sq.m. (20% Reduction in common

    spaces)

    Stairs : 5.2 W/sq.m. (20% Reduction in common spaces)

    Parking : 1.76 W/sq.m. (20% Reduction in common

    spaces)

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTD

    ENERGY CONSERVATION AND

    BUILDING CODE

  • ASSUMPTIONS: S. NO. MODEL

    INPUT

    PARAMETER

    S

    PROPOSED CASE

    7 Receptacle

    Equip

    Power Density

    Bedroom : 1.2 w/sq.ft

    Drawing Room: 2 w/sq.ft

    Kitchen : 3 w/sq.ft

    Study Room : 0.5 w/sq.ft

    8. Occupancy

    Sensors

    None

    9. Daylight

    Sensors

    None

    10. HVAC System

    TypeAir Cooled Unitary

    Packaged Terminal Air Conditioner

    11. Cooling

    EquipmentCategory: PTAC

    COP : 3.52

    12. Coil Capacity Cooling Coil Capacity : 100

    Heating Coil Capacity : 100

    13. Heating

    Equipment

    Electric Resistance

    14. Base Utility Type: Elevators

    Hourly Consumption: 60.0 kW

    15. Utility Rates 5.25 Rs/ kWH

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTD

    ENERGY CONSERVATION AND

    BUILDING CODE

  • SIMULATION RESULTS : ENERGY CONSUMPTIONS

    Towers Tower 1 Tower 2 Tower 3

    Energy Type

    Energy

    10^3

    kWh/yr

    Energy

    10^3

    kWh/yr

    Energy

    10^3

    kWh/yr

    Lighting - ConditionedElectricity 48.68 37.86 6.94

    Lighting - UnconditionedElectricity 64.96 50.53 9.26

    Space HeatingElectricity 0.00 0.00 0.00

    Space CoolingElectricity 228.73 177.91 32.59

    Heat RejectionElectricity 15.70 12.21 2.24

    Fans - ConditionedElectricity 33.32 25.92 4.75

    Total Building Consumption (Q) Electricity391.39 304.43 55.77

    Conditioned Area 4094.49 3407.09 987.14Non Conditioned Area

    5004.37 4163.24 531.54

    Total Area (A) in Sq. m. 9098.87 7571.33 1518.69

    EPI (E1) in Kwh/sq.m./yr.= Q/A Q/A Q/A

    = 57.8 111.11 111.11

    ECBC Bench marked EPI 70 70 70

    Proposed case reduction in energy consumption over benchmark consumption

    35.81% 48.% 47.54

    WEIGHTED AVARAGE IMPACTREDUCTION THROUGH THE PROJECT

    40.97%

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTD

    ENERGY CONSERVATION AND

    BUILDING CODE

  • CONCLUSIONS:

    • Criteria 8

    - 7 Points are being achieved in Criteria 8 due to achievement of benchmark

    Energy Performance Index and EPI reduction of 40.97% over the base case.

    Percentage Energy Performance Index Points

    10% reduction from benchmark (Mandatory) 2

    20% reduction from benchmark 3

    30% reduction from benchmark 5

    40% reduction from benchmark 7

    50% reduction from benchmark 10

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTD

    ENERGY CONSERVATION AND

    BUILDING CODE

  • 1) ECM’S

    2) Envelope Details

    3) Sectional Details

    4) Schedules

    5) External Lighting Calculation

    ANNEXURE:

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTD

    ENERGY CONSERVATION AND

    BUILDING CODE

  • ENERGY CONSERVATIVE METHODS (ECM’S):

    The proposed building achieves energy reduction by following

    ECM’s

    1. Efficient HVAC systems.

    Residential Area – PTAC COP 3.5

    2. Good envelope properties for wall, Roof and Glazing

    Wall - 200 mm AAC Block (U-Value = 0.67 W/m²·°C)

    Roof - 150mm RCC slab with 120mm Brick Bat

    (U – Value = 0.58 W/m²·°C)

    Glazing - U value for Residential = 1.6 W/m²·°C, VLT =

    33%

    3. Shading devices – As per Design.

    4. Solar Cells – Solar panels of 12 KWp capacity.

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTD

    ENERGY CONSERVATION AND

    BUILDING CODE

  • ENVELOPE DETAILS:

    WALLS

    ROOF

    GLASS For Residential : U - factor: 3 W/m²·°C SHGC: 0.25

    Autoclaved Aerated Concrete Blocks (AAC)

    Material DescriptionThickness

    (mm)Conductivity (w/m.c)

    Resistance (m2.C/W)

    Outside Surface Resist. 0.059

    External Plaster (Cement plaster, sand

    aggregate)16 0.72 0.027777778

    AAC Block 200 0.17 1.212

    Internal Plaster (Gypsum plaster, sand

    aggregate)12 0.22 0.063636364

    Inside Surface Resist. 0.121

    R-Value 1.48U-Value 0.674

    Roof

    Material DescriptionThickness

    (mm)Conductivity (w/m.c)

    Resistance (m2.C/W)

    Outside Surface Resist. 0.05864

    China Mosaic 50 1.5996 0.031257814

    20mm Mortar 20 0.72702 0.02750956

    40mm Screed 40 0.72 0.055555556

    40mm Screed 40 0.72 0.055555556

    Brick Bat Coba 120 0.811 0.147965475

    150mm RCC 150 1.4 0.107142857

    Inside Surface Resist. 0.12063

    R-Value 0.60U-Value 1.655

    ENERGY CONSERVATION AND

    BUILDING CODE

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTD

  • SECTIONAL DETAILS:

    Wall : 200 mm AAC Block (U-0.67 W/m²·°C)

    ROOF : 150mm RCC Slab with 50mm PUF Roof (U-1.65

    W/m²·°C)

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTDENERGY CONSERVATION AND

    BUILDING CODE

  • SCHEDULES: People

    BEDROOM Timing percentage(%)

    People

    Midnight 07:00 AM 80

    07:00 AM 10:00 PM 20

    10:00 PM Midnight 70

    LIVING ROOM Timing percentage(%)

    People

    Midnight 07:00 AM 0

    07:00 AM 10:00 AM 30

    10:00 AM 06:00 PM 50

    06:00 PM 10:00 PM 30

    10:00 PM Midnight 0

    KITCHEN Timing percentage(%)

    People

    Midnight 07:00 AM 0

    07:00 AM 09:00 AM 80

    09:00 AM 01:00 PM 0

    01:00 PM 02:00 PM 80

    02:00 PM 07:00 PM 0

    07:00 PM 09:00 PM 80

    09:00 PM Midnight 0

    CLUB HOUSE Timing percentage(%)

    People

    Midnight 06:00 AM 0

    06:00 AM 09:00 AM 70

    09:00 AM 05:00 PM 20

    05:00 PM 08:00 PM 70

    08:00 PM Midnight 0

    Multipurpose Hall Timing percentage(%)

    People

    Midnight 06:00 PM 0

    06:00 PM 10:00 PM 20

    10:00 PM Midnight 10

    Sports/Game Timing percentage(%)

    People

    Midnight 06:00 AM 0

    06:00 AM 10:00 AM 30

    10:00 AM 01:00 PM 0

    01:00 PM 02:00 PM 30

    02:00 PM 05:00 PM 0

    05:00 PM 08:00 PM 30

    08:00 PM Midnight 0

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTDENERGY CONSERVATION AND

    BUILDING CODE

  • SCHEDULES: Lighting BEDROOM Timing percentage(%)

    LIGHTINGMidnight 06:00 PM 1006:00 PM Midnight 60

    LIVING ROOM Timing percentage(%)

    LIGHTINGMidnight 06:00 PM 1006:00 PM Midnight 60

    KITCHEN Timing percentage(%)

    LIGHTING

    Midnight 07:00 AM 507:00 AM 09:00 AM 6009:00 AM 06:00 PM 006:00 PM 10:00 PM 8010:00 PM Midnight 5

    PASSAGE/LOBBY Timing percentage(%)

    LIGHTINGMidnight 06:00 AM 2006:00 AM 07:00 PM 006:00 PM Midnight 70

    SURFACE PARKING Timing percentage(%)

    LIGHTINGMidnight 07:00 AM 5007:00 AM 06:00 PM 006:00 PM Midnight 80

    BASEMENT PARKING Timing percentage(%)

    LIGHTINGMidnight 07:00 AM 6007:00 AM 06:00 PM 2006:00 PM Midnight 80

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTDENERGY CONSERVATION AND

    BUILDING CODE

  • SCHEDULES: Lighting

    Multipurpose Hall Timing percentage(%)

    LIGHTING

    Midnight 06:00 PM 0

    06:00 PM 10:00 PM 30

    10:00 PM Midnight 20

    Sports/Game Timing percentage(%)

    LIGHTING

    Midnight 06:00 AM 0

    06:00 AM 10:00 AM 40

    10:00 AM 01:00 PM 0

    01:00 PM 02:00 PM 40

    02:00 PM 05:00 PM 0

    05:00 PM 08:00 PM 70

    08:00 PM Midnight 0

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTDENERGY CONSERVATION AND

    BUILDING CODE

  • SCHEDULES: Miscellaneous / EquipmentsBEDROOM Timing percentage(%)

    Misc. / Equipments

    Midnight 07:00 AM 10

    07:00 AM 10:00 AM 20

    10:00 AM 06:00 PM 50

    06:00 PM 10:00 PM 80

    10:00 PM Midnight 20

    LIVING ROOM Timing percentage(%)

    Misc. / Equipments

    Midnight 07:00 AM 0

    07:00 AM 10:00 AM 20

    10:00 AM 06:00 PM 50

    06:00 PM 10:00 PM 70

    10:00 PM Midnight 20

    KITCHEN Timing percentage(%)

    Misc. / Equipments

    Midnight 07:00 AM 10

    07:00 AM 09:00 AM 70

    09:00 AM 01:00 PM 20

    01:00 PM 02:00 PM 40

    02:00 PM 07:00 PM 20

    07:00 PM 09:00 PM 70

    09:00 PM Midnight 10

    CLUB HOUSE Timing percentage(%)

    Misc. / Equipments

    Midnight 06:00 AM 0

    06:00 AM 09:00 AM 60

    09:00 AM 05:00 PM 20

    05:00 PM 08:00 PM 60

    08:00 PM Midnight 10

    ATMOS SUSTAINABLE SOLUTIONS PVT.

    LTDENERGY CONSERVATION AND

    BUILDING CODE