View
225
Download
0
Tags:
Embed Size (px)
Citation preview
Introduction
• Last autumn, I showed the GyakuDataBase method in meeting @ Matsumoto.
• Now, I’m developing.
• I try time stamping systematically.
• So, I’m looking for good separation parameter.
• Today, I show a part of it.
Gyaku Data Base
Emulsion track
match
no match
allowance
match
• Emulsion track extension down stream.• Look for SFT hits on the Emul track ??
Allowance : +- (1mm + 3mrad z axis)SFT plane alignment + angle measurement error
(and scattering error)
match
SFT = 10layer (x,y-projection), 2layer (u-projection)
beam
Select Scan Back tracks with GyakuDataBase
• I selected 165tracks matching with SFT trigger. I thought these are from Interaction.
• Checked again and selected good match 31tracks with SFT trigger from them.
• And, best matched tracks are 20 in 31tracks.– 13 are Rock Muon type.– 7 are Interaction type.
How decide best match ?
• Important point, there is SFT hits directory below plane of ECC target.
• If matching is real, SFT hits exist far 1~2 fibers .
• Also It’s same low momentum particle. Because no material between ECC target to directory below SFT plane.
point
Residual of Emulsion track to hits ofdirectory below plane
• This showed residual.• extension emulsion track to below SFT plane.• Select tracks matching with SFT trigger as Rock Muon type by eyes.
y x x y2 3
mm
If matching is real, its residual will be into 500m.
mm
mm
mm
31tracks scan back resultSFT trigger type
Scan back result
Penetrate stop Not yet
Rock Muon 2 0 11 13
Interaction 0 4 3 7
Unknown 0 1 4 5
Not so good 2 4 1 7
Select scan back track like BL040 and Scan back result
SFT trigger type
Follow up result
Penetrate Stop
Rock Muon 7 0 7
Interaction 0 2 2
summary
• Now looking for good separation parameter.• One is below SFT plane hits.• This selection power is very good.• Bud SFT link efficiency is effected by SFT
efficiency.• So, other selection parameter will be needed
for efficiency.