2
Efficient pulse compression measurements with the R&S®FSW signal and spectrum analyzer Radar under test Reference waveform RF Radar system using digital pulse compression filter Signal generation Pulse compression filter IFA LNA Signal processing PA RX protection Ant Test & Measurement Application Card | 01.00 Time sidelobe measurements optimize radar system performance Your task Pulse compression is often used in radar applications to combine the advantages of excellent range resolution and high energy with a low peak power output. This is achieved by designing radar waveforms with a time-band- width product much greater than one, which is typically the case with pulsed frequency or phase modulated sig- nals. A corresponding matched filter in the radar’s receive channel automatically compresses the radar echo signal in time and increases the peak value by the approximate pulse compression ratio. The output of the pulse compres- sion filter is a narrow pulse with a large peak value in the time domain. The R&S®FSW signal and spectrum analyzer measures and analyzes time sidelobes to optimize compressed radar signals as well as radar hardware components and systems. Developers of radar systems can improve and immediately validate their design using automated and reproducible measurements. Time sidelobe measurements optimize radar system performance Unfortunately, this technique increases the radar’s blind range because of longer pulse transmission times, and it affects the Doppler measurement due to a reduced SNR in cases where a compression filter has mismatch (ambigu- ity function). In addition, range-Doppler coupling may oc- cur, where the Doppler shift of the echo signal affects the range measurement accuracy. The autocorrelation func- tion of the expanded pulse consists not only of the main peak, but also contains time sidelobes at the matched filter output that may mask smaller echo signals or cause false alarms. Pulse compression performance is influenced by the radar waveform as well as the system design and components. Therefore, a controllable, repeatable and time-saving test environment is the key for achieving top-level radar per- formance. This is especially true for multifunction radars aimed at superior probability of detection, high accuracy, and resolution both in the range and the Doppler domain. T & M solution The R&S®FSW signal and spectrum analyzer equipped with the R&S®FSW-K6 pulse measurement and R&S®FSW-K6S time sidelobe measurement options effectively analyzes pulse parameters and additionally pulse compression. This solution allows radar design en- gineers to verify and optimize their radar signals, signal processing and components using automated, reproduc- ible measurements. In addition, signal disturbances such as intentional echo signal distortion can also be verified in a straightforward manner. For the test setup, the radar transmitter is connected to the RF input of the R&S®FSW. An ideal waveform in digital I/Q (iq-tar) format is loaded into the analyzer, which operates as a pulse compression filter. The ideal waveform can be synthetically generated or previously recorded with the R&S®FSW.

Time sidelobe Radar system using digital pulse …...Efficient pulse compression measurements with the R&S®FSW signal and spectrum analyzer Reference waveform Radar under test RF

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Time sidelobe Radar system using digital pulse …...Efficient pulse compression measurements with the R&S®FSW signal and spectrum analyzer Reference waveform Radar under test RF

Efficient pulse compression measurements with the R&S®FSW signal and spectrum analyzer

Radar under testReference waveform

RF

Radar system using digital pulse compression filter

Signalgeneration

Pulse compressionfilter

IFA LNA

Signal processing

PA

RXprotection

Ant

Test

& M

easu

rem

ent

Appl

icat

ion

Card

| 01

.00

Tim

e si

delo

be m

easu

rem

ents

op

timize

rada

r sys

tem

per

form

ance

Your taskPulse compression is often used in radar applications to combine the advantages of excellent range resolution and high energy with a low peak power output. This is achieved by designing radar waveforms with a time-band-width product much greater than one, which is typically the case with pulsed frequency or phase modulated sig-nals. A corresponding matched filter in the radar’s receive channel automatically compresses the radar echo signal in time and increases the peak value by the approximate pulse compression ratio. The output of the pulse compres-sion filter is a narrow pulse with a large peak value in the time domain.

The R&S®FSW signal and spectrum analyzer measures and analyzes time sidelobes to optimize compressed radar signals as well as radar hardware components and systems. Developers of radar systems can improve and immediately validate their design using automated and reproducible measurements.

Time sidelobe measurements optimize radar system performance Unfortunately, this technique increases the radar’s blind

range because of longer pulse transmission times, and it affects the Doppler measurement due to a reduced SNR in cases where a compression filter has mismatch (ambigu-ity function). In addition, range-Doppler coupling may oc-cur, where the Doppler shift of the echo signal affects the range measurement accuracy. The autocorrelation func-tion of the expanded pulse consists not only of the main peak, but also contains time sidelobes at the matched filter output that may mask smaller echo signals or cause false alarms.

Pulse compression performance is influenced by the radar waveform as well as the system design and components. Therefore, a controllable, repeatable and time-saving test environment is the key for achieving top-level radar per-formance. This is especially true for multifunction radars aimed at superior probability of detection, high accuracy, and resolution both in the range and the Doppler domain.

T & M solutionThe R&S®FSW signal and spectrum analyzer equipped with the R&S®FSW-K6 pulse measurement and R&S®FSW-K6S time sidelobe measurement options effectively analyzes pulse parameters and additionally pulse compression. This solution allows radar design en-gineers to verify and optimize their radar signals, signal processing and components using automated, reproduc-ible measurements. In addition, signal disturbances such as intentional echo signal distortion can also be verified in a straightforward manner. For the test setup, the radar transmitter is connected to the RF input of the R&S®FSW. An ideal waveform in digital I/Q (iq-tar) format is loaded into the analyzer, which operates as a pulse compression filter. The ideal waveform can be synthetically generated or previously recorded with the R&S®FSW.

FSW-K6_time_sidelobe_measurements_ac_3607-2626-92.indd 1 31.07.2015 12:43:09

Page 2: Time sidelobe Radar system using digital pulse …...Efficient pulse compression measurements with the R&S®FSW signal and spectrum analyzer Reference waveform Radar under test RF

The R&S®FSW displays the correlated magnitude, frequency and phase error traces as well as pulse compression parameters for a linear frequency

modulated waveform.

Rohde & Schwarz GmbH & Co. KG

Europe, Africa, Middle East | +49 89 4129 12345

North America | 1 888 TEST RSA (1 888 837 87 72)

Latin America | +1 410 910 79 88

Asia Pacific | +65 65 13 04 88

China | +86 800 810 82 28 | +86 400 650 58 96

www.rohde-schwarz.com

[email protected]

R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG

Trade names are trademarks of the owners

PD 3607.2626.92 | Version 01.00 | July 2015 (as)

R&S®FSW-K6S; Time sidelobe measurements optimize radar system performance

Data without tolerance limits is not binding | Subject to change

© 2015 Rohde & Schwarz GmbH & Co. KG | 81671 Munich, Germany

3607

.262

6.92

01.

00 P

DP

1 e

n

3607262692

The actual measured radar pulse waveform is cross-correlated with the ideal I/Q waveform. In the case of an ideal measured pulse, the two waveforms will be identical, exhibiting the same narrow mainlobe curve. In practice, however, the waveforms will differ, e.g. due to I/Q modula-tor inaccuracies, phase noise and VSWR between stages. The more the waveforms differ, the less effective is the compression ratio, and time sidelobes may increase, caus-ing radar system performance to degrade.

The differences between measured and ideal wave-forms result in sidelobes in addition to the mainlobe. The crosscorrelation function is clearly visualized by the corre-lated magnitude graph displayed on the R&S®FSW, allow-ing efficient evaluation.

The main pulse parameters, including mainlobe width, sidelobe suppression, sidelobe delay, main and sidelobe integrated power, peak correlation and mainlobe fre-quency and phase, are also automatically measured and displayed.

The R&S®FSW with pulse and time sidelobe measurement options allows radar system designers and engineers to efficiently optimize, verify and test their pulse compression radar waveforms, components and the entire system to achieve superior radar performance.

Key features ❙ Frequency range from 2 Hz to 85 GHz; up to 500 GHz with external mixers

❙ Wide analysis bandwidth up to 2 GHz ❙ Low phase noise of –137 dBc (1 Hz) at 10 kHz offset (1 GHz carrier)

Key benefits ❙ Can be used to analyze your own proprietary waveforms ❙ Easy configuration and fast measurement results ❙ Automated detection, measurement and analysis of pulses and pulse compression

See alsowww.rohde-schwarz.com/product/FSW

FSW-K6_time_sidelobe_measurements_ac_3607-2626-92.indd 2 31.07.2015 12:43:09