Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
Timber Frame Systems Building for a Better Future
80mm PIR Rigid InsulationFull Height Between Joists
Airtight Membrane wrappedaround junction of floor joist
VCL / Foil ReflectiveAirtight Membrane
Plasterboard Supplied & Fitted by others
38mm Service Cavity Batten
Passive Standard Foundation U-ValueFrom U-Value 0.105W/m2K - 0.13W/m2K
25x50mm Counter Battens
Breathable Roofing Membrane
Cellulose Insulation
Engineered Rafter
Eaves Closer
Vaulted / Cut RoofU-Value 0.14W/m2K
Vapour Control Layer& Airtight Membrane
22mm Ceiling Service Cavity Batten
38mm Wall Service Cavity Batten
140mm Wall System Suitable for allExternal Leaf Options ie: block work,
stone, cement board, timber cladding etc…
140mm Stud WallU-Value 0.14W/m2K
300mm High DensityMineral Wool Insulation
140mm x 38mm Timber Studs
140mm High DensityMineral Wool Insulation
9mm OSB ExternalSheathing
TF200 Thermo Reflective Breather Membrane
22mm ChipboardFlooring Deck
Engineered Open MetalWeb Floor Joist
Ceiling PlasterboardSupplied & Fitted by Others
40mm PIR Rigid Insulation
Internal Service Duct
300mm EPS Insulation
150mm Power FloatedReinforced Concrete Slab
Reinforced Concrete Ringbeam
Compacted Hardcore Stone
50mm Sand Blinding
Radon Barrier/DPM
Perimeter Ringbeam Footing Installed for Masonry
External Leaf (if required)
Perimeter landscaping, footpath,paving & backfilling by others
Service Ducts Fitted & broughtout 1 meter from edge of EPS
Closed Panel SystemThe MBC closed panel system offers a variety of insulation options based around a 140mm stud timber frame. The section below details a 0.14 W/m2K U-Value wall with a 0.14 W/m2K U-Value roof.
Vapour Control Layer /Ceiling Airtight Membrane
25x50mm Counter Battens
Breathable Roofing Membrane
Cellulose Insulation
Engineered Rafter
Eaves Closer
Airtight Membrane wrappedaround junction of floor joist
300mm Twin Studs – 38mm x 89mm x 2 timber studs set122mm apart with 300mmCellulose Insulation Pressure Pumped Between Studs
Passive Standard Twin Wall SystemSuitable for all External Leaf Options ie: block work, stone, cement board, timberCladding etc…
300mm Cellulose Insulation
12.5mm BreathableMedite Vent BoardTF200 Thermo ReflectiveBreather Membrane
Perimeter Ringbeam Footing Installed for Masonry External Leaf (if required)
EPS formwork removed as required (by others) in line with perimeter landscaping needs
Service Ducts Fitted & brought out 1 meter from edge of EPS
Perimeter landscaping,paving & backfilling by others
25mm Ceiling ServiceCavity Batten
89mm InternalTimber Stud Wall
22mm Chipboard Flooring Deck
Engineered Open MetalWeb Floor Joist
12.5mm Smart Ply‘VAP’ Airtight Board
38mm Service Cavity Batten
PlasterboardSupplied & Fitted by others
150mm Power FloatedReinforced Concrete Slab
Reinforced Concrete Ringbeam
300mm EPS Insulation
Radon Barrier / DPM
50mm Sand Blinding
Compacted Hardcore Stone
Internal Service Duct
Passive Standard RoofU-Value 0.10W/m2K
Passive Standard Twin Wall U-Value 0.12W/m2K
Passive Standard Foundation U-ValueFrom 0.105W/m2K – 0.13W/m2K
Passive House Technical SectionPassive Twin Wall• Delivers a U-Value of 0.12 W/m2K• Continuous thermal layer envelopes the structure completely• Suitable for all external finishes ie: Brick, render, Cladding
Passive Foundation• Delivers a U-Value from 0.105W/m2K – 0.13W/m2K• Engineered to thermally encase concrete slab in high
performance insulation• Eliminates cold bridge typically found at wall/floor junctions
Breathable wall protects thermal envelope
Roof optionsTo provide roofing solutions for Cut / Vaulted Roofs and Flat Roofs, MBC utilise open metal web Posi Joists which see parallel timber flanges plated together with an engineered steel web component. The steel webs are plated in a ‘V’ formation, providing
a lightweight structural roof joist, or flat roof joist, that can span greater distances in comparison to standard solid joists. Insulation is fitted by MBC within the roof structures, with the insulation located in between the Posi Joists.
Cellulose Insulation
Cellulose Insulation
Breathable Roofing
Membrane
Breathable Roofing
Membrane
Engineered Posi Rafter
Engineered Posi Rafter
25mm Ceiling Service Cavity Batten
25mm Ceiling Service Cavity Batten
*Plasterboard Supplied and Fitted by Others
*Plasterboard Supplied and Fitted by Others
*Plasterboard Supplied and Fitted by Others
*Plasterboard Supplied and Fitted by Others
VCL / Ceiling Airtight
Membrane
VCL / Ceiling Airtight
Membrane
25mm x 50mm
Counter Batten
Cellulose Insulation Cellulose
InsulationCeiling VCL /
Airtight Membrane
Ceiling VCL / Airtight
Membrane
25mm Ceiling Service Cavity
Batten
25mm Ceiling Service Cavity
BattenEngineered Posi Joist
Engineered Posi Joist
PIR Insulation
PIR Insulation
9mm OSB & Breather Membrane
9mm OSB & Breather Membrane
50mm minimum
firring pieceTo create fall & full ventilation
50mm minimum
firring pieceTo create fall & full ventilation
OSB DeckOSB Deck
25mm x 50mm
Counter Batten
Cut / Vaulted Roof System U-Value 0.10W/m2K
Posi Joist Flat Roof System U-Value 0.10W/m2K
Cut / Vaulted Roof System U-Value 0.14W/m2K
Posi Joist Flat Roof System U-Value 0.13W/m2K
0.18WW/m²K U-Value 0.14W/m²K U-Value 0.11W/m²K U-Value
Wall optionsThe MBC closed panel system incorporates many of the philosophies used in the Passive system. All systems offer excellent air tightness and are significantly greater than building regulation requirements.
FoundationsThe passive foundation delivers a U-Value of 0.105 – 0.13 W/m2K and is designed to complete the continuously insulated envelope of our Passive system, this is achieved as the insulation in the wall sits on the insulation in the foundation, removing what is usually a very difficult junction to overcome thermally. Many of our customers
also incorporate the MBC foundation system into their standard timber frame projects, our experience shows that there is huge value in one company taking responsibility for the entire structural thermal envelope of foundations, walls and roof.
TF200 Thermo Reflective Breather
Membrane
TF200 Thermo Reflective Breather
Membrane
TF200 Thermo Reflective Breather
Membrane
140mm x 38mm Timber Studs
140mm x 38mm Timber Studs
140mm x 38mm Timber Studs
140mm High Density Mineral Wool Insulation
140mm High Density Mineral Wool Insulation
110mm PIR Insulation
80mm PIR Rigid Insulation
40mm PIR Rigid Insulation
VCL / Foil Reflective
Membrane
VCL / Foil Reflective
Membrane
VCL / Foil Reflective
Membrane
38mm Service Cavity Battens
35mm Service Cavity Battens
35mm Service Cavity Battens
9mm OSB External
Sheathing
9mm OSB External
Sheathing
9mm OSB External
Sheathing
IL/01/0318/01
Superb energy efficient passive homes - reduced energy costsMBC also offer high performance windows & doors
Tel: 01452 346499 [email protected] mbctimberframe.co.uk
UK Office: Quedgeley Court, Shepherd Road, Gloucester, GL2 5EL.
twitter.com/MBCTimberFrame facebook.com/mbctimberframe
Metal Web Joists
Windows
TrussesMBC Timber Frame design and manufacture metal web joists inhouse, these are used within all of our timber frame systems and are also available on a supply only basis for traditional build projects.
Metal web joists make running services much quicker and easier, they are also able to span great lengths without the need for additional steel work.
MBC are able to offer a wide range of timber and alu-clad windows, these range from 0.6 W/m2K to 1.2 W/m2K U-Values. Once the windows are installed by MBC, they are sealed in preparation for an air test that is guaranteed as part of the MBC package.
With our inhouse roof designer and truss press, MBC are able to utilise a wide range of trusses within our projects, these are also available on a supply only basis.
From fink trusses, to attic and raised tie trusses these are manufactured to the highest quality.