client
project
drawing
scale
original size
passed
checked
drawn
date
status
job no. drawing no. revision
1. Do not scale this drawing - if in doubt ask.2. All sizes to be checked on site prior to construction.3. This drawing is the copyright of the author.
A1
s m i t h d e s i g n a s s o c i a t e s
01387 250579www.smithdesign.co.uk
30 Castle Street, Dumfries DG1 [email protected]
Dumfries Leatherhead Glasgow
New Luce Community Trust
Kenmuir ArmsProposed Refurbishment
ProposedGround Floor Plan
1:50 JB
-
-
04.06.2020
WARRANT
D2786 AL(0)025 A
N o r t h
Electrical
All electrical work will be carried out by a competent electrical contractor.
The installation, i.e.the design, construction, inspection and testing
will be completed in strict accordance with BS7671:2008 (2015)
incorporating any amendments (IEE Wiring Regulations, 17th Edition)
and in compliance with other Building Regulations, in particular,
will not compromise fire-stopping, structural integrity, sound insulation,
thermal insulation and other related matters.
The contractor will provide the relevant certification at the completion
of this part of the work.
Outlets and controls of electrical fixtures and systems
should be positioned at least 350 mm from any internal corner,
projecting wall or similar obstruction and,
unless the need for a higher location can be demonstrated, not more
than 1.2 m above floor level.
This would include fixtures such as sockets, switches,
fire alarm call points and timer controls or programmers.
Within this height range:
Light switches should be positioned at a height of between 900 mm
and 1.1 m above floor level.
Standard switched or unswitched socket outlets and outlets for
other services such as telephone or television should be positioned
at least 400 mm above floor level.
Above an obstruction, such as a worktop, fixtures should be at least
150 mm above the projecting surface.
Where socket outlets are concealed, such as to the rear of white goods
in a kitchen, separate switching should be provided in an accessible
position, to allow appliances to be isolated.
LEGEND
All layouts are suggestions only.
Electrical layout, Emergency Lighting to BS 5266 Part 1 &
Fire Alarm to BS 5839 Part 1
designed and installed by suitably qualified persons.
Fire Exit Signage (New / Existing)
External Emergency Lighting
Radiator (R) TRV.
Towel Rail (TR) TRV.
Thermostat 24/7
LED recessed downlights fixed & adj' /
Wall lights - White / Chrome
E = Emergency light Small LED
External lights controlled with dusk + timer
Fans / Inlet & Outlets + Humidistat + Trickle Ventilation to 3.14.3
30l/s Hob Hood - SS
All ducted to wall vent /roof slate vent outlet Ubbink UB11
+ 3 Pole Isolator to regulations
3ph Mains & Fusebox - Existing & Relocated
Light Switch - Wall mounted
Light Switch - Pull Cord
Razor Socket 115/230V (Bathroom)
Socket for lights controlled by light switch
Double Socket Low (400mm above floor)
Some sockets to have inbuilt USB power outlets
Double Socket High (Above Counter Top)
SD - Ionisation / Multi & Manual Break Glass
Opti SD - Optical
HD - Heat Detectors
CO - Carbon Monoxide
CO2 - Carbon Dioxide (Air Quality Monitor)
Fire Alarm Panel & Repeater
Category L2 Alarm System to BS 5839 Part 1:2017
Category D Alarm System to BS 5839 Part 6:2019
to be designed & installed by competent person.
All to 2.11 Mains & battery back up & Interlinked
SD
Opti SD
HD
CO
CO2
SD
Opti SD
HD
CO
R
5
R
T
Fire
E
xit
FAP
E
BG
Rev A - BC Updates 31.07.2020
Concrete slab
Oil Tank
M
A
I N
S
T
R
E
E
T
R
/
W
W
a
ll
Bar
Store
Kitchen
Snug
Hall
WC
F WC
AWC M WC
Cl.
Flat
Entrance
WCs
Bar / Restaurant
S
c
r
e
e
n
1
S
l
i
d
i
n
g
d
o
u
b
l
e
g
l
a
z
e
d
p
a
n
e
l
s
R
o
o
f
o
v
e
r
h
a
n
g
Low & High Sections to Bar
to 4.2.10 @ 750 & 1100mm
Sitting Out Area
Office
Cellar
Boilers
Extension 38m2
Brick pillar
R
/
W
1
0
5
0
0
Brick wall removed.
Ground levels adjusted and
graded
Block Paving Area
c. 240m2
Brick wall removed.
Ground levels adjusted and
graded
Brick wall & gate removed.
New stone dyke infills gap.
Ground levels adjusted and
graded
Garden
Entrance
Main
Entrance
Room 4
Utility
WC
En-suite
Room 4
Entrance
bollard
bollard
4
0
0
0
B
gently graded path
D01
2 x 475
D04
D05
D06
2 x 650mm
D25
c.950mm
GW01
GW02
GW03
GW04
GW10
GW15
GW11
GW12
GW13
GW14
new door & window
S
c
r
e
e
n
2
17m2
55m2
Block Paving Area for
refuse bins etc
Bins to D&GC latest
requirements
1.8m
hig
h hit and m
iss vertic
al fence
1
.8
m
h
ig
h
h
it a
n
d
m
iss ve
rtica
l fe
n
ce
Car Parking 1
SVP
Rodding Point
AVV
Rodding Point
Rodding Point
New bottom outlet IC
New IC
New IC
New IC
Under stair void inspection panel at low level in WC
Vent Grills at high and low levels within WC
Stair underside protected to 30minFR
Deep seal easy clean
Shower drain
RWP
Roddable gulley
RWP
Roddable gulley
D10 60S FRVP
926mm
D11 60S FRVP
926mm
D16
826mm
D17
926mm
D18
826mm
D19
826mm
D21
800mm
D22
926mm
D23 VP
926mm
D24
c.950mm
D26 VP
926mm
D27 VP
826mm
D28
826mm
D29
926mm
D13 60S FRVP
Screen 60FR
925mm
D12 60S FRVP
826mm
D15 60S FRVP
925mm
D20 60S FR
826mm
C
h
a
n
n
e
l
d
r
a
i
n
C
h
a
n
n
e
l
d
r
a
i
n
S
c
r
e
e
n
4
6
0
F
R
+
s
t
a
i
n
e
d
g
l
a
s
s
S
c
r
e
e
n
5
6
0
F
R
+
s
t
a
i
n
e
d
g
l
a
s
s
H
D
H
D
H
D
H
D
H
D
H
D
1
S
c
r
e
e
n
6
a
(
&
6
b
)
6
0
F
R
AVV
1
New IC
1
9
7
0
Large internal wall removed
f
o
r
m
a
t
i
o
n
1
1
0
0
c
.
2
0
0
0
c
.
4
7
0
0
6
0
4
c
.
5
1
0
0
c
.
1
2
0
0
AVV
SVP
New IC
c.4
0
0
0
c.3500
1
2
0
0
N
o
n
co
m
b
u
sta
b
le
F
ire
S
to
p
D
P
C
6
0
F
R
R
o
ckw
o
o
l H
o
rizo
n
ta
l F
ire
S
to
p
a
t
G
F
C
e
ilin
g
le
ve
l a
ll a
ro
u
n
d
b
u
ild
in
g
N
o
n
co
m
b
u
sta
b
le
F
ire
S
to
p
D
P
C
6
0
F
R
R
o
ckw
o
o
l H
o
rizo
n
ta
l F
ire
S
to
p
a
t
G
F
C
e
ilin
g
le
ve
l a
ll a
ro
u
n
d
b
u
ild
in
g
N
o
n
co
m
b
u
sta
b
le
F
ire
S
to
p
D
P
C
6
0
F
R
R
o
ckw
o
o
l H
o
rizo
n
ta
l F
ire
S
to
p
a
t
G
F
C
e
ilin
g
le
ve
l a
ll a
ro
u
n
d
b
u
ild
in
g
N
o
n
c
o
m
b
u
s
t
a
b
l
e
F
i
r
e
S
t
o
p
D
P
C
6
0
F
R
R
o
c
k
w
o
o
l
H
o
r
i
z
o
n
t
a
l
F
i
r
e
S
t
o
p
a
t
G
F
C
e
i
l
i
n
g
l
e
v
e
l
a
l
l
a
r
o
u
n
d
b
u
i
l
d
i
n
g
Non combustable Fire Stop DPC 60FR
Rockwool Vertical Fire Stop
Non combustable Fire Stop DPC 60FR
Rockwool Vertical Fire Stop
Non combustable Fire Stops DPC 60FR
Rockwool Vertical Fire Stops
Non combustable Fire Stop DPC 60FR
Rockwool Vertical Fire Stop
Non combustable Fire Stop DPC 60FR
Rockwool Vertical Fire Stop
Non combustable Fire Stop DPC 60FR
Rockwool Vertical Fire Stop
SVP
SVP pipework and
boxing at high level
8
5
0
8
5
0
F
i
r
e
E
x
i
t
FAP
Rub Off Mat
Rub Off Mat
F
i
r
e
E
x
i
t
F
i
r
e
E
x
i
t
F
i
r
e
E
x
i
t
F
i
r
e
E
x
i
t
F
i
r
e
E
x
i
t
F
ire
E
xit
F
ire
E
xit
F
ire
E
xit
F
ire
E
xit
Beer & Soft Drinks
Python route & Duct
8
0
0
c
l
e
a
r
E
PIR
PIR
PIR
PIR
PIR
5
5
5
5
E
E
E
E
E
E
PIR
PIR
E
E
E
E
E
E
1
4
0
0
shower tray
former at FFL
Whole floor gently
graded towards
shower tray & drain
Low profile raised
water bar at door
Internal walls removed only
after checking by engineer!
Existing 3Ph Mains & Fusebox
Relocated
Cook Range
Electric / Gas
Prep'
Servery
Dishwash
E
E
Proposed new position of 3Ph
Mains, Meter & Fuse boxes
N
e
w
s
t
e
e
l
b
e
a
m
s
1
H
R
F
R
N
e
w
s
t
e
e
l
b
e
a
m
s
1
H
R
F
R
PIR
PIR
H
D
TD
WM
D
P
T
D
D
P
W
M
Extract Vent
Extract Vent
Extract Vent
Extract Vent
Input Vent
Ventilation Fans,
(Option Heat Exchanger)
& ducts at high level
Extract Vent
Extract Vent
Extract Vent Roof AIR OUT
Roof AIR IN
H
ig
h
le
ve
l b
o
xin
g
fo
r
re
cta
n
g
u
la
r ve
n
t' d
u
ct
H
ig
h
le
ve
l b
o
xin
g
fo
r
re
cta
n
g
u
la
r ve
n
t' d
u
ct
PIR
PIR
PIR
PIR
Extract Fan
Cowled
Extract Fan Grill
Aluminium Grill over
A
p
p
r
o
x
i
m
a
t
e
n
e
w
r
o
u
t
e
S
P
C
a
b
l
e
&
D
u
c
t
r
o
u
t
e
t
o
n
e
w
s
w
i
t
c
h
&
m
e
t
e
r
A
p
p
ro
xim
a
te
n
e
w
ro
u
te
S
P
C
a
b
le
&
D
u
ct ro
u
te
to
n
e
w
sw
itch
&
m
e
te
r
Internal walls removed only
after checking by engineer!
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
5
SD
SD
SD
SD
SD
BG
SD
SD
SD
SD
HD
HD
HD
SD
R
R
TR
R
R
R
R
R
R
R
R
R
R
R
Windows blocked up
AVVR
5
BG
BG
BG
BG
R
SVP pipework and
boxing at high level
SVP
New IC
Services (small power etc) Layout by kitchen designer
Gas related design by qualified gas engineer.
If gas then gas interlock* with ventilation
*or as required by gas regulations
FAP (Repeater)
SVP
SVP pipework and
boxing at high level
Landline
Telephone Point
T
New IC
New drainage to existing
Septic Tank & Outlet
Existing LPG boiler(s)
checked & replaced
accordingly
SD
Non combustable Fire Stop DPC 60FR
Rockwool Vertical Fire Stop
Non combustable Fire Stop DPC 60FR
Rockwool Vertical Fire Stops
Non combustable Fire Stop DPC 60FR
Rockwool Vertical Fire Stops
B
e
a
m
&
b
l
o
c
k
f
l
o
o
r
t
o
s
t
a
i
r
e
n
c
l
o
s
u
r
e
CO
CO
1
5
2
5
1000
M
u
l
t
i
p
l
e
H
o
u
s
e
L
i
g
h
t
C
o
n
t
r
o
l
s
M
u
l
t
i
p
l
e
H
o
u
s
e
L
i
g
h
t
C
o
n
t
r
o
l
s
250
250mm going
170mm rise
1000mm between handrails
2
5
0
All walls within Kitchen & Store
have whiterock or equal wall cladding floor to ceiling.
Stainless Steel sheet behind cooking area.
Sinks
Wash hand
Sink
Rodding Point
D26a
926mm
8
5
0
Input Vent
Sink
E
E
E
E
E
E
E
E
E
E
Canopy over 60l/s
3
5
8
SD
S
t
a
i
r
B
o
x
i
n
g
a
b
o
v
e
Multi fuel stove
and hearth
Multi fuel stove
and hearth
D01 left open during
operational hours
Fire Alarm
linked to Hotel
EVCS BS 5839: Part 9: 2011
EVCS
Extract Fan
Extract Fan
Extract Fan
A
W
C
x
2
A
l
a
r
m
r
e
p
e
a
t
e
r
A
W
C
x
2
A
l
a
r
m
r
e
p
e
a
t
e
r
AWC Alarm Indicator
WC Alarm indicator
Rub Off Mat
Doc M Shower additional grab
handles, floor drain & deep seal trap
Emergency Pull
Pull down seat all to 3.12.10 Fig 3.32
Reinorce walls with plywood and studs
m
in
2
3
0
0
m
i
n
f
i
n
i
s
h
e
d
2
3
0
0
Roof AIR IN
Extract Vent
Extract Vent
Roof AIR OUT
L
i
n
t
e
l
s
3
0
0
m
m
a
b
o
v
e
D
2
2
d
o
o
r
h
e
a
d
t
o
a
l
l
o
w
f
o
r
v
e
n
t
i
l
a
t
i
o
n
d
u
c
t
s
/
g
r
i
l
l
s
1
4
0
m
m
7
N
/
m
m
2
b
l
o
c
k
w
o
r
k
1
4
0
m
m
7
N
/
m
m
2
b
l
o
c
k
w
o
r
k
1
4
0
m
m
7
N
/
m
m
2
b
l
o
c
k
w
o
r
k
1
4
0
m
m
7
N
/
m
m
2
b
l
o
c
k
w
o
r
k
1
4
0
m
m
7
N
/
m
m
2
b
l
o
c
k
w
o
r
k
1
4
0
m
m
7
N
/
m
m
2
b
l
o
c
k
w
o
r
k
c
.
2
0
0
c
.
2
0
0
c
.
2
0
0
R
a
ckin
g
w
a
ll o
f 9
5
x 4
5
C
1
6
@
6
0
0
m
m
c/c
NOTE: Refer to Structural Engineers
Information for Steel Beams & Columns,
lintels and padstones etc