Thermo-Brace® S.I.B.™TER No. 1703-16
© 2018 Barricade® Building Products
Why use Thermo-Brace S.I.B.?
What isThermo-Brace S.I.B.?
Thermo-Brace S.I.B. has superior strength to OSB, a WRB,and insulation in one solution.
Unlike polyiso and XPS, Neopor GPS doesn’t use HFC gas agents for R-value, which can deplete over time. XPS only retains 90% of it’s initial R-value over its lifetime and the R-value of Neopor GPS is up to 30% higher than EPS (white foam).
• Neopor GPS is GREENGUARD certified for Gold Indoor Air Quality • Complies with the energy code using 2ʺx4ʺ conventional framing instead of 2ʺx6ʺ • Can be installed with the foam side facing in or out, the WRB is on both sides. • Reduces thermal bridging • Stable pricing • Lightweight
• Structural Insulative Board • Complies with the 2012, 2015, and 2018 International Energy Codes for continuous insulative sheathing • Available in R-3 or R-5 thickness • Excellent long-term thermal resistance (LTTR) • WRB on both sides • Mold resistant
Exclusively using BASF Neopor® GPS (Graphite Polystyrene) rigid foam in conjunction with Barricade® Thermo-Brace™, Thermo-Brace S.I.B. is todays energy-efficient and cost-effective insulation solution for architects, contractors, and builders.
WITH
Made of 4 Layers:
Barricade Thermo-BraceStructural Sheathing
Neopor GPS
Thermo-Brace w/ Non-Reflective Facer (WRB)
SR Facer* (WRB)
4-in-1 Solution• WRB
• Structural
• Air Barrier
• R-Value
*Safe-Reflective facer is designed and guaranteed to not overheat vinyl.
ReversibleFront: Safe-Reflective WRB
Reverse: Cool Gray WRBInstall it either way!
Cool Gray WRB
Safe-Reflective WRB
Thermo-Brace® S.I.B.™TER No. 1703-16
© 2018 Barricade® Building Products
Barricade® Building Products10351 Verdon RoadDoswell, VA 23047For more information visit www.barricadebp.comContact us at [email protected]
Contact us for Warranty Info:
4
4
6 67
7
8
5 5
332
2
1
1
Insulation requirements as defined by the 2015 IECCU.S. Department of Energy Section R402
Sizes and Packaging:
a. First value is cavity insulation, second is continuousinsulation, so “13+5” means R-13 cavity insulation plusR-5 continuous insulation.
ClimateZone
WoodFrame Wall
R-Value
1 13
2 13
3 20 or 13+5a
4 exceptMarine 20 or 13+5a
5 andMarine 4 20 or 13+5a
6 20+5 or 13+10a
7 and 8 20+5 or 13+10a
Table R402.1.2
R-Value
R3
R5
Thickness
³⁄4"
1¹⁄8"
Sheets/Pallet
70
40
Pallets/Truck
24
24
Standard Dimensions*
48" x 96"
48" x 108"
48" x 120"*Custom lengths available
Installation
For use as a WRB noted in IRC section R703.2 and IBC section 1404.2, use Barricade Extreme™ or Barricade Seam Tape on joints and seams.
Fasteners fit standard 1” wide-crown staple guns.
Thermo-Brace S.I.B. can be installed with foam inside or out, and the fastener schedule is printed on both sides.
DO NOT overdrive fasteners.
Starting at the top left of the panel, begin fastening from top to bottom, referring to the fastener schedule on the front side of the panel for proper fastener spacing.
Moving across the panel, attach fasteners at the top and bottom of the panel until you reach the next stud (it is important when using staples to fasten them in a parallel direction to the stud).
Fasten panel in numerical order repeating the procedure described in steps 1 and 2.
Continue until the Thermo-Brace S.I.B. panel is properly secured to the frame.
Fastener Sizes
Foam Outward
R3
R5
Foam Inward
R3
R5
¹⁵⁄16" Crown x 1³⁄4"Leg 16 ga. Staples
¹⁵⁄16" Crown x 2"Leg 16 ga. Staples
1³⁄4" x 11 ga. SmoothShank Roofing Nail
1³⁄4" x 11 ga. RingShank Roofing Nail
USES STANDARD, READILYAVAILABLE STAPLE GUNS!