2
WE WILL BLOW YOU AWAY WITH OUR FANTASTIC RANGE OF... Grayson Thermal Systems Wharfdale House, 257 Wharfdale Road, Tyseley, Birmingham, B11 2DP United Kingdom T: +44 (0)121 700 5600 F: +44 (0)121 700 5601 E: [email protected] BLOWERS AND FANS Grayson THERMAL SYSTEMS MANUFACTURERS OF ENGINE COOLING & HVAC PRODUCTS / ASSOCIATED COMPONENTS HEAD OFFICE & ALUMINIUM TECHNOLOGY CENTRE Wharfdale House 257 Wharfdale Road Tyseley, Birmingham United Kingdom B11 2DP Tel: +44 (0) 121 700 5600 Fax: +44 (0) 121 700 5601 COPPER BRASS & HVAC MANUFACTURING PLANT 1 Wharf Road Tyseley, Birmingham West Midlands United Kingdom B11 2DX Tel: +44 (0) 121 708 1830 Fax: +44 (0) 121 765 4896 AIR CONDITIONING & VEHICLE SERVICING DIVISION Unit 44 Elmdon Trading Estate Bickenhill Lane Birmingham, West Midlands United Kingdom B37 7HE Tel: +44 (0) 121 781 6660 Fax: +44 (0) 121 781 6661 SOUTHERN DISTRIBUTION CENTRE Unit 6 Rutherford Centre Daneshill Industrial Estate Basingstoke, Hampshire United Kingdom RG24 8PB NORTHERN DISTRIBUTION CENTRE Unit 2, Southlink Business Park Oldham, Lancashire United Kingdom OL4 1DE NORTH AMERICAN SALES OFFICE 1809 E Broadway Suite 177 Oviedo, Florida 32765 USA SCOTTISH DISTRIBUTION CENTRE Unit 6F Whitestone Place Whitehall Industrial Estate Bathgate, West Lothian United Kingdom EH48 2EW Grayson Reference: HP-2811-000 Supplier Reference: VA014-BP7/C34S Spal Fan Voltage: 24V Diameter: 190mm Blowing/Pushing Grayson Reference: HP-2812-000 Supplier Reference: VA32-B101-62A Spal Axial Motor Fan Voltage: 24V Diameter: 96mm Sucking/Pulling Grayson Reference: HP-2815-000 Supplier Reference: TK781294 Thermo King Condenser Fan Voltage: 24V Diameter: 305mm Sucking/Pulling Grayson Reference: HP-2810-000 Supplier Reference: VA09-BP8/C-54A Spal Condenser Fan Voltage: 24V Diameter: 280mm Sucking/Pulling Grayson Reference: HP-2813-000 Supplier Reference: VA34-BP70/LL-36S Spal Condenser Fan Voltage: 24V Diameter: 305mm Blowing/Pushing Grayson Reference: HP3HF005 Supplier Reference: VA21-B37-C-45A Spal Heater Fan Voltage: 24V Diameter: 140mm Sucking/Pulling Grayson Reference: HP-2814-000 Supplier Reference: 1E08656G01 Thermo King MRT Athenia Condenser Fan Voltage: 24V Diameter: 358.5mm Blowing/Pushing AXIAL MOTOR FANS TIP 1 Making sure you have selected the correct blower is vital to the heang performance of your vehicle. Many blowers look the same but perform completely different in terms of airflow and back pressure. You must make sure the cost of the unit does not persuade you to buy the wrong blower. TIP 2 Air side blockages also reduce the performance of your blower. When there is a blockage in your heater, the air that should be circulang through your blower is non existent. However, the blower will be performing at the same output as it would be with the airflow present, but without the air to cool the motor/bearings the unit will overheat, resulng in the failure of your blower. TIP 3 It has also been shown that poorly fied blowers reduce the overall efficiency of the system. As air leaves the vehicle via gaps between the mounng plate & the blower, this results in a loss of capacity and performance. TIP 4 Finally, if your blower has a damaged scroll or wheel, the performance of the blower will again be reduced. The airflow will be affected along with the balance of the blower. When the balance of the blower wheels is affected, it can result in the damage of the motor and therefore ruin the blower. HELP Grayson Reference: MP-1020-025 Supplier Reference: VA09-BP50/C-27A Spal Condenser Fan Voltage: 24V Diameter: 280mm Sucking/Pulling Grayson Reference: MP-1013-017 Supplier Reference: VA09-BP8-C-27/S Spal Condenser Fan Voltage: 24V Diameter: 280mm Blowing/Pushing Grayson Reference: HP-2608-000 Supplier Reference: 146230-0530 Condenser Fan Grayson Reference: HP3HF6080 OE Reference: CH71832 Heater Fan, 166mm, Rimmed (Red) D-Shape use with Motor HP3HM8100 FAN BLADES Grayson Reference: HP-2809-000 OE Reference: 4070153 Condenser Fan Grayson Reference: HP3HF332A OE Reference: SA0332A Heater Fan, 160mm, Not Rimmed Grayson Reference: HP-2498-001 OE Reference: 052.514 Heavac Plasc Fan Grayson Reference: HP-2498-002 O.E Reference: 052.515 Heavac Plasc Fan Grayson Reference: VA11-BP12/C- 29S-24V Supplier Reference: VA11-BP12/C-29S-24V Spal Condenser Fan Voltage: 24V Diameter: 280mm Blowing/Pushing Air Flow Air Flow Air Flow Air Flow Air Flow Air Flow Air Flow Air Flow Air Flow Air Flow Grayson Reference: HP3HF005/100 Supplier Reference: AD0924HB-Y71GL UVE/Whisper Fan Voltage: 24V Diameter: 92.5mm Blowing/Pushing Air Flow SPAL HEAVAC AURORA SUTRAK THERMO KING HISPACOLD OUR BRANDS

THERMAL SYSTEMS WE WILL BLOW YOU AWAY WITH OUR …WE WILL BLOW YOU AWAY WITH OUR FANTASTIC RANGE OF... Grayson Thermal Systems Wharfdale House, 257 Wharfdale Road, Tyseley, Birmingham,

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: THERMAL SYSTEMS WE WILL BLOW YOU AWAY WITH OUR …WE WILL BLOW YOU AWAY WITH OUR FANTASTIC RANGE OF... Grayson Thermal Systems Wharfdale House, 257 Wharfdale Road, Tyseley, Birmingham,

WE WILL BLOW YOU AWAY WITH OUR FANTASTIC RANGE

OF...

Grayson Thermal Systems Wharfdale House, 257 Wharfdale Road, Tyseley, Birmingham, B11 2DP United Kingdom T: +44 (0)121 700 5600 F: +44 (0)121 700 5601 E: [email protected]

BLOWERS AND FANS

GraysonTHERMAL SYSTEMS

MANUFACTURERS OF ENGINE COOLING & HVAC PRODUCTS / ASSOCIATED COMPONENTS

HEAD OFFICE & ALUMINIUMTECHNOLOGY CENTREWharfdale House257 Wharfdale RoadTyseley, BirminghamUnited Kingdom B11 2DPTel: +44 (0) 121 700 5600Fax: +44 (0) 121 700 5601

COPPER BRASS & HVACMANUFACTURING PLANT1 Wharf RoadTyseley, BirminghamWest MidlandsUnited Kingdom B11 2DX Tel: +44 (0) 121 708 1830Fax: +44 (0) 121 765 4896

AIR CONDITIONING & VEHICLE SERVICING DIVISIONUnit 44 Elmdon Trading EstateBickenhill LaneBirmingham, West Midlands United Kingdom B37 7HETel: +44 (0) 121 781 6660Fax: +44 (0) 121 781 6661

SOUTHERNDISTRIBUTION CENTREUnit 6 Rutherford CentreDaneshill Industrial EstateBasingstoke, HampshireUnited Kingdom RG24 8PB

NORTHERNDISTRIBUTION CENTREUnit 2, Southlink Business ParkOldham, LancashireUnited Kingdom OL4 1DE

NORTH AMERICAN SALES OFFICE1809 E BroadwaySuite 177Oviedo, Florida32765USA

SCOTTISH DISTRIBUTION CENTREUnit 6F Whitestone PlaceWhitehall Industrial EstateBathgate, West LothianUnited Kingdom EH48 2EW

Grayson Reference: HP-2811-000 Supplier Reference: VA014-BP7/C34SSpal FanVoltage: 24VDiameter: 190mmBlowing/Pushing

Grayson Reference: HP-2812-000 Supplier Reference: VA32-B101-62ASpal Axial Motor FanVoltage: 24VDiameter: 96mmSucking/Pulling

Grayson Reference: HP-2815-000 Supplier Reference: TK781294Thermo King Condenser FanVoltage: 24VDiameter: 305mmSucking/Pulling

Grayson Reference: HP-2810-000 Supplier Reference: VA09-BP8/C-54ASpal Condenser FanVoltage: 24VDiameter: 280mmSucking/Pulling

Grayson Reference: HP-2813-000 Supplier Reference: VA34-BP70/LL-36SSpal Condenser FanVoltage: 24VDiameter: 305mmBlowing/Pushing

Grayson Reference: HP3HF005 Supplier Reference: VA21-B37-C-45ASpal Heater FanVoltage: 24VDiameter: 140mmSucking/Pulling

Grayson Reference: HP-2814-000 Supplier Reference: 1E08656G01Thermo King MRT Athenia Condenser FanVoltage: 24VDiameter: 358.5mmBlowing/Pushing

AXIAL MOTOR FANS

TIP 1 Making sure you have selected the correct blower is vital to the heating performance of your vehicle. Many blowers look the same but perform completely different in terms of airflow and back pressure. You must make sure the cost of the unit does not persuade you to buy the wrong blower.

TIP 2 Air side blockages also reduce the performance of your blower. When there is a blockage in your heater, the air that should be circulating through your blower is non existent. However, the blower will be performing at the same output as it would be with the airflow present, but without the air to cool the motor/bearings the unit will overheat, resulting in the failure of your blower.

TIP 3 It has also been shown that poorly fitted blowers reduce the overall efficiency of the system. As air leaves the vehicle via gaps between the mounting plate & the blower, this results in a loss of capacity and performance.

TIP 4 Finally, if your blower has a damaged scroll or wheel, the performance of the blower will again be reduced. The airflow will be affected along with the balance of the blower. When the balance of the blower wheels is affected, it can result in the damage of the motor and therefore ruin the blower.

HELP

Grayson Reference: MP-1020-025 Supplier Reference: VA09-BP50/C-27ASpal Condenser FanVoltage: 24VDiameter: 280mmSucking/Pulling

Grayson Reference: MP-1013-017 Supplier Reference: VA09-BP8-C-27/SSpal Condenser FanVoltage: 24VDiameter: 280mmBlowing/Pushing

Grayson Reference: HP-2608-000 Supplier Reference: 146230-0530Condenser Fan

Grayson Reference: HP3HF6080 OE Reference: CH71832Heater Fan, 166mm, Rimmed (Red) D-Shape use with Motor HP3HM8100

FAN BLADES

Grayson Reference: HP-2809-000 OE Reference: 4070153Condenser Fan

Grayson Reference: HP3HF332A OE Reference: SA0332AHeater Fan, 160mm, Not Rimmed

Grayson Reference: HP-2498-001 OE Reference: 052.514Heavac Plastic Fan

Grayson Reference: HP-2498-002 O.E Reference: 052.515 Heavac Plastic Fan

Grayson Reference: VA11-BP12/C-29S-24V Supplier Reference: VA11-BP12/C-29S-24VSpal Condenser FanVoltage: 24VDiameter: 280mmBlowing/Pushing

Air Flow

Air Flow

Air Flow

Air Flow

Air Flow

Air Flow

Air Flow

Air Flow

Air Flow

Air Flow

Grayson Reference: HP3HF005/100 Supplier Reference: AD0924HB-Y71GLUVE/Whisper FanVoltage: 24VDiameter: 92.5mmBlowing/Pushing

Air Flow

SPAL HEAVAC AURORA SUTRAK THERMO KING HISPACOLD

OUR BRANDS

Page 2: THERMAL SYSTEMS WE WILL BLOW YOU AWAY WITH OUR …WE WILL BLOW YOU AWAY WITH OUR FANTASTIC RANGE OF... Grayson Thermal Systems Wharfdale House, 257 Wharfdale Road, Tyseley, Birmingham,

1200

Standard

SINGLE BLOWERS

TWIN BLOWERS

Use the diagram to the left as a reference to measure the dimensions of your blower. This will help you determine which blower is suitable for your vehicle.A: Length B: Width C: Height

The colour key below should assist you in identifying what range each blower belongs to:

DIMENSIONS

Grayson Reference: HP3HB0300324SSecondary Reference: 008-B100-93DSingle Blower Unit - Standard Range Voltage: 24VCFM: 300 No. of Speeds: 3Dimensions:A: 119mmB: 113mmC: 127mm

Grayson Reference: HP3HB0400324SSecondary Reference: 009-B70-74DSingle Blower Unit - Standard Range Voltage: 24VCFM: 400 No. of Speeds: 3Dimensions: A: 139mmB: 146mmC: 163.9mm

Grayson Reference: HP3HB0500324SSecondary Reference: CA 3515CTwin Blower Unit - Standard RangeVoltage: 24V CFM: 500 No. of Speeds: 3 Dimensions:A: 350mm B: 110mm C: 100mm

Grayson Reference: HP3HB0600324SSecondary Reference: 009-B40-22Twin Blower Unit - Standard Range Voltage: 24VCFM: 600 No. of Speeds: 3Dimensions:A: 335mmB: 146mmC: 163.9mm

Grayson Reference: HP3HB0601124TSecondary Reference: 009-B40IET-22Twin Blower Unit - Internal Thermal Cutout Voltage: 24VCFM: 600 No. of Speeds: 1Dimensions: A: 335mmB: 145mmC: 100mm

Grayson Reference: HP3HB0800324S Secondary Reference: 008-B40-02 3 SP Twin Blower Unit - Standard RangeVoltage: 24V CFM: 800 No. of Speeds: 3 Dimensions: A: 310mm B: 113.1mmC: 127.5mm

Grayson Reference: HP3HB0603324S Secondary Reference: 722-400-06 3 SPDTwin Blower Unit - Economy RangeVoltage: 24VCFM: 600 No. of Speeds: 3Dimensions:A: 337mm B: 151mm C: 168mm

Grayson Reference: HP3HB0730324SSecondary Reference: 131-302-0003Twin Blower Unit - Standard Range Voltage: 24V CFM: 730 No. of Speeds: 3 Dimensions: A: 350mm B: 133mm C: 156mm

Grayson Reference: HP3HB0800124SSecondary Reference: 008-B40-02/30000487Twin Blower Unit - Standard/No ResistorVoltage: 24VCFM: 800 No. of Speeds: 1 Dimensions:A: 310mmB: 113.1mmC: 127.5mm

Grayson Reference: HP3HB0602424VSecondary Reference: TK781296Twin Blower Unit - Very Long LifeVoltage: 24VCFM: 600 No. of Speeds: 1 Dimensions:A: 340mmB: 148mmC: 168mm

Economy VLL (Very Long Life) Brushless

300 400

600

600 730

800

600

500

800

Grayson Reference: HP3HB0801324S Secondary Reference: 008-B45-02 3SP Twin Blower Unit - Standard Range Voltage: 24V CFM: 800No. of Speeds: 3 Dimensions: A: 310mm B: 113.5mm C:128mm

Grayson Reference: HP3HB0802324SSecondary Reference: 008-B46-02 3SPTwin Blower Unit - Standard Range Voltage: 24VCFM: 800 No. of Speeds: 3Dimensions:A: 310mmB: 113.5mmC: 128mm

Grayson Reference: HP3HB0850324SSecondary Reference: 006-B46-22Twin Blower Unit - Standard Range Voltage: 24VCFM: 850 No of Speeds: 3 Dimensions:A: 351mm B: 139.8mmC: 167.5mm

Grayson Reference: HP3HB1001324SSecondary Reference: 006-B45-22 Twin Blower Unit - Standard RangeVoltage: 24V CFM: 1000No. of Speeds: 3 Dimensions: A: 351mm B: 139.8mm C: 167.5mm

Grayson Reference: HP3HB1050324S Secondary Reference: 006-B40-22 Twin Blower Unit - Standard RangeVoltage: 24VCFM: 1050 No. of Speeds: 3 Dimensions: A: 351mmB: 140mmC: 135mm

Grayson Reference: HP3HB1150124SSecondary Reference: 006-B39-22/30000076 Twin Blower Unit - Standard/No ResistorVoltage: 24V CFM: 1150No. of Speeds: 1 Dimensions: A: 351mm B: 139.8mmC: 167.5mm

Grayson Reference: HP3HB1200324SSecondary Reference: CA3831AR Twin Blower Unit - Sub Plate SaloonVoltage: 24V CFM: 1200 No. of Speeds: 3 Dimensions: A: 376mm B: 180mm C: 174mm

Grayson Reference: HP3HB1051424VSecondary Reference: TK781297Twin Blower Unit - Very Long LifeVoltage: 24VCFM: 1050 No. of Speeds: 4 Dimensions: A: 351mmB: 140mm C: 140mm

Grayson Reference: HP3HB1000324SSecondary Reference: 722-350-02-1050-3 SPDTwin Blower Unit - Economy RangeVoltage: 24VCFM: 1000 No. of Speeds: 3 Dimensions: A: 353mm B: 144mm C: 175mm

Grayson Reference: HP3HB0810324S Secondary Reference: 712-310-07-3 SPDTwin Blower Unit - Economy Range Voltage: 24V CFM: 800 No. of Speeds: 3 Dimensions: A: 302.5mm B: 130mm C: 128mm

Grayson Reference: HP3HB1150324SSecondary Reference: 006-B39-22 Twin Blower Unit - Standard RangeVoltage: 24V CFM: 1150 No. of Speeds: 3 Dimensions: A: 351mm B: 139.8mmC: 167.5mm

Grayson Reference: HP3HB0851424VSecondary Reference: TK781364Twin Blower Unit - Very Long LifeVoltage: 24VCFM: 850 No. of Speeds: 4 Dimensions:A: 351mmB: 140mmC: 156mm

Grayson Reference: HP3HB1050124SSecondary Reference: 006-B40-22/3000082 Twin Blower Unit - Standard/No Resistor Voltage: 24V CFM: 1050 No. of Speeds: 1Dimensions:A: 351mm B: 167.5mm C: 139.8mm

Grayson Reference: HP3HB1200124SSecondary Reference: CA3831AR Twin Blower Unit - Sub Plate DemisterVoltage: 24V CFM: 1200 No. of Speeds: 1 Dimensions: A: 376mm B: 180mm C: 174mm

Grayson Reference: HP3HB1202324V Secondary Reference: TK781258Twin Blower Unit - Very Long LifeVoltage: 24VCFM: 1200 No. of Speeds: 3 Dimensions:A: 548mm B: 170mm C: 188mm

800

800 1000

1000 1050 1050

1150 1150 1200

1200

850

1200

1050

Grayson Reference: HP3HB1250124S Secondary Reference: 012-B39-78Twin Blower Unit - Standard Range Voltage: 24V CFM: 1250 No. of Speeds: 1 Dimensions: A: 351mmB: 154.3mmC: 183.5mm

1250

850

Grayson Reference: HP3HB1401124LSecondary Reference: EV.C.020-BBL.303-95Twin Blower Unit - Brushless RangeVoltage: 24VCFM: 1400 No. of Speeds: 1 Dimensions:A: 351mmB: 141mmC: 162mm

Grayson Reference: HP3HB1400124L Secondary Reference: 053-002Twin Blower Unit - Brushless Range Voltage: 24V CFM: 1400No. of Speeds: 1 Dimensions: A: 350mm B: 140mm C: 135mm

Grayson Reference: HP3HB1402124LSecondary Reference: 28.20.01.050Twin Blower Unit - Standard RangeVoltage: 24V CFM: 1400 No. of Speeds: 1Dimensions: A: 380mm B: 133mm C: 140mm

Grayson Reference: HP3HB1300124TSecondary Reference: 006-B50IET-22Twin Blower Unit - Standard RangeVoltage: 24V CFM: 1300 No. of Speeds: 1 Dimensions: A: 350mm B: 140mm C: 135mm

1300 1400

1400

800

Grayson Reference: HP3HB057524ACSecondary Reference: 132-552-0000Single Blower Unit Anti-Clockwise StandardVoltage: 24VCFM: 575No. of Speeds: 3Dimensions:A: 131mmB: 198mmC: 205mm

Grayson Reference: HP3HB057524CSecondary Reference: 132-562-0000Single Blower Unit - Clockwise StandardVoltage: 24VCFM: 575No. of Speeds: 3Dimensions:A: 131mmB: 198mmC: 205mm

450

Grayson Reference: HP3HB0451224LSecondary Reference: 5300066Single Blower Unit - Standard Range Voltage: 24VCFM: 450 No. of Speeds: 2Dimensions: A: 215mm B: 95mm C: 195mm

Grayson Reference: HP3HB0450224LSecondary Reference: 5300065Single Blower Unit - Standard Range Voltage: 24VCFM: 450 No. of Speeds: 2Dimensions: A: 215mm B: 95mm C: 195mm

450

575 575

600

1400

600

Grayson Reference: HP3HB0610324SSecondary Reference: 131-202-0068Twin Blower Unit - Standard RangeVoltage: 24V CFM: 600 No. of Speeds: 3 Dimensions: A: 334mm B: 103mm C: 113mm

370

Grayson Reference: HP3HB0370324SSecondary Reference: 131-102-0064Twin Blower Unit - Standard RangeVoltage: 24V CFM: 370 No. of Speeds: 3 Dimensions: A: 246mm B: 102mm C: 95mm

1000

Grayson Reference: HP3HB1010324SSecondary Reference: 131-502-0003Twin Blower Unit - Standard RangeVoltage: 24V CFM: 1000 No. of Speeds: 3 Dimensions: A: 428mm B: 152mm C: 115mm

Grayson Reference: HP3HB1210324SSecondary Reference: 131-602-0111Twin Blower Unit - Standard RangeVoltage: 24V CFM: 1200 No. of Speeds: 3 Dimensions: A: 376mm B: 174mm C: 185mm

1290

Grayson Reference: HP3HB1290324SSecondary Reference: 131-102-0064+3SRTwin Blower Unit - Standard RangeVoltage: 24V CFM: 1290 No. of Speeds: 3 Dimensions: A: 351mm B: 154.3mm C: 183.5mm