Thermal Performance Specifications NatHERS Certificate Form 15 Stamped Plans

Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

Thermal Performance Specifications NatHERS Certificate Form 15 Stamped Plans

Page 2: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

As per the National Construction Code (NCC) Building Code of Australia (BCA)

DATE 7th December 2018 OUR REFERENCE [JOB NO.] 182587

PROPERTY DETAILS

CLIENT NAME PLATINUM AUSTRALIA

PROPERTY DESCRIPTION LOT 157 ON SP264094

SITE

ADDRESS

LOT 157 CORELLA STREET LOWOOD 4311 Lot Number and/or House Number and Street Suburb or Town and State Postcode

BUILDING CLASS 1

LGA SOMERSET REGIONAL COUNCIL

EXTERNAL WALLS

Construction Insulation R-Value Colour Detail

Lower Level

CLADDING FOIL 1.0

INTERNAL WALLS

Construction Insulation R-Value Detail

STUD NIL

PARTY WALLS BATTS 2.0MIN. AS PER PLANS

FLOORS

Construction Insulation R-Value Covering Area

SLAB ON GROUND NIL

ROOF

Construction Insulation R-Value Colour Detail

COLORBOND SISALATION 1.0 BAL

CEILINGS

Construction Insulation R-Value Detail

PLASTER BATTS 2.5

WINDOWS

Glass Frame U Value SHGC Area (M2)

CLEAR ALUMINIUM 6.70 0.70

NOTES

CEILING FANS AS PER ELECTRICAL PLAN

Page 3: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments.For more details see www.nathers.gov.au

Nationwide House Energy Rating Scheme* Certificate Certificate number: Certificate Date: êStar rating:

MJ/m2

Assessor details

Accreditation number: Name: Organisation:Email: Phone: Declaration of interest:

Key construction and insulation materials (see following pages for details)

Construction:

Insulation:

Glazing:

Plan documents

Plan ref/date: Prepared by:

Net floor area (m2)

Conditioned: Unconditioned: Garage: TOTAL:

Annual thermal performance loads (MJ/m2)

Heating: Cooling: TOTAL:

Dwelling details

Street: Suburb: State:

Type:

Lot/DP number:

Postcode:NCC Class:NatHERSclimate zone:

Ceiling penetrations (see following pages for details)

Sealed: Unsealed: TOTAL:**

**NOTE: This total is themaximum number of ceilingpenetrations allowed to aceiling (under a roof) for thiscertificate. If this number isexceded in construction thenthis certificate IS NOT VALIDand a new certificate is required.Loss of ceiling insulation for thepenetrations listed has beentaken into account with the rating.

Principle downlight type:

Window selection - default windows only

Note on allowable window values:Only a 5% tolerance to the nominatedSHGC window values shown on page 2can be used with this rating.

Note: Only a +/- 5% SHGC tolerance is allowed with this rating.

NB: This tolerance ONLY applies to SHGC, the U-value can always be lower but not higher than the values stated on page 2.

If any of windows selected are outside the 5% tolerance then this certificate is no longer valid and the dwelling will need to be rerated to confirm compliance.

Overview

Scan to access this certificate online and confirm this is valid.

Software:

AAO:

Exposure:

07 Dec 20180003437837 8.4BERS Pro v4.3.0.0 (3.13) cannot be used to model 'roof windows'. Roof windows are 'openable or fixed windows in a roof' and do not have a shaft, as distinctfrom skylights which incorporate a built-in shaft and are not ventilated. BERS Pro v4.3 can only model skylights. If a roof window is present on the floor planthen this certificate is not valid.

8.4VIC/BDAV/15/1698Marcus GazsikCyber [email protected]

BERS Pro v4.3.0.2d (3.13)

BDAV

33.8Unit 1, CORELLA STREETLOWOODQLD 4311New Dwelling 1A

9157/SP264094 Suburban

212

23Fibro Cavity Panel on BattensCorrugated IronConcrete Slab on GroundReflective wall insulationR2.5 ceiling insulationNo floor insulation

LED

ALM-002-01 A Aluminium B SG Clear

117.046.037.0

163.06.3

27.533.8

LOT 157 CORELLA STREETAUSTRALIAN FLOOR PLANS

Page 1 of 5

Page 4: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

Window type and performance valueWindow ID Window type U-value SHGCALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70

Window scheduleLocation Window ID Window no. Height (mm) Width (mm) Orientation Outdoor shadeEntry ALM-002-01 A n/a 2100 1500 SE No ShadingKitchen/Living ALM-002-01 A n/a 1200 1500 NE No ShadingKitchen/Living ALM-002-01 A n/a 2100 2400 NE No ShadingBedroom 1 ALM-002-01 A n/a 900 1500 NW No ShadingBedroom 1 ALM-002-01 A n/a 2100 2400 NE No ShadingEns ALM-002-01 A n/a 900 1500 NW No ShadingBedroom 2 ALM-002-01 A n/a 900 1500 NE No ShadingBath ALM-002-01 A n/a 1200 1500 NE No ShadingBedroom 3 ALM-002-01 A n/a 2100 1500 SE No Shading

Roof window and skylight type and performance valueID Window type U-value SHGCNone Present

Roof window and skylight scheduleLocation ID Roof

window/skylightno.

Area (m²) Orientation Outdoor shade Indoorshade/diffuser

None Present

External wall typeID Wall type Insulation Wall wrap or foilEW-1 Fibro Cavity Panel on Battens Foil, Anti-glare one side, Reflective other Yes

External wall scheduleLocation ID Width (mm) Height (mm) Orientation Fixed Shade Eaves

(mm)Garage EW-1 6095 2400 SE No 400Garage EW-1 6100 2400 SW No 500Entry EW-1 2100 2400 SE No 600Entry EW-1 600 2400 SW No 6600Entry EW-1 2095 2400 NE No 2500Kitchen/Living EW-1 7490 2400 NE No 500Bedroom 1 EW-1 4095 2400 NW No 500Bedroom 1 EW-1 4395 2400 NE No 500Ens EW-1 2095 2400 NW No 500Laundry EW-1 1490 2400 NE No 500Bedroom 2 EW-1 3195 2400 NE No 500Bedroom 2 EW-1 600 2400 SE No 8000Bath EW-1 2190 2400 NE No 500Bedroom 3 EW-1 3095 2400 NE No 500

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 2 of 5

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0003437837 Certificate Date: 07 Dec 2018 ★ Star rating: 8.4

Building features

Page 5: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

Bedroom 3 EW-1 2000 2400 SE No 2700

Internal wall typeWall type Area (m²) Insulation Wall wrap or foilIW-1 - Cavity wall, direct fixplasterboard, single gap

106.0 No insulation No

IW-2 - Shaft liner party wall withplaster

53.0 Bulk Insulation both sides of shaft liner R1.5 No

FloorsLocation Construction Area (m²) Sub floor

ventilationAddedinsulation

Covering

Garage Concrete Slab on Ground100mm

36.9 None No Insulation Ceramic Tiles8mm

Entry Concrete Slab on Ground100mm

7.1 None No Insulation Ceramic Tiles8mm

Kitchen/Living Concrete Slab on Ground100mm

63.3 None No Insulation Ceramic Tiles8mm

Bedroom 1 Concrete Slab on Ground100mm

17.7 None No Insulation Ceramic Tiles8mm

WIR Concrete Slab on Ground100mm

3.7 None No Insulation Ceramic Tiles8mm

Ens Concrete Slab on Ground100mm

5.0 None No Insulation Ceramic Tiles8mm

Laundry Concrete Slab on Ground100mm

2.6 None No Insulation Ceramic Tiles8mm

Bedroom 2 Concrete Slab on Ground100mm

11.4 None No Insulation Ceramic Tiles8mm

Bath Concrete Slab on Ground100mm

6.4 None No Insulation Ceramic Tiles8mm

Bedroom 3 Concrete Slab on Ground100mm

9.3 None No Insulation Ceramic Tiles8mm

Ceiling typeLocation Construction Added

insulationRoof spaceabove

Garage Plasterboard Bulk InsulationR2.5

Yes

Entry Plasterboard Bulk InsulationR2.5

Yes

Kitchen/Living Plasterboard Bulk InsulationR2.5

Yes

Bedroom 1 Plasterboard Bulk InsulationR2.5

Yes

WIR Plasterboard Bulk InsulationR2.5

Yes

Ens Plasterboard Bulk InsulationR2.5

Yes

Laundry Plasterboard Yes

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0003437837 Certificate Date: 07 Dec 2018 ★ Star rating: 8.4

Building features continued

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 3 of 5

Page 6: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

Bulk InsulationR2.5

Bedroom 2 Plasterboard Bulk InsulationR2.5

Yes

Bath Plasterboard Bulk InsulationR2.5

Yes

Bedroom 3 Plasterboard Bulk InsulationR2.5

Yes

Ceiling penetrationsLocation Number Type Diameter (mm) Sealed/unsealedEntry 2 Downlights - LED 150 SealedKitchen/Living 11 Downlights - LED 150 SealedBedroom 1 2 Downlights - LED 150 SealedWIR 1 Downlights - LED 150 SealedEns 1 Downlights - LED 150 SealedEns 1 Exhaust Fans 300 UnsealedLaundry 1 Downlights - LED 150 SealedBedroom 2 1 Downlights - LED 150 SealedBath 1 Downlights - LED 150 SealedBath 1 Exhaust Fans 300 UnsealedBedroom 3 1 Downlights - LED 150 Sealed

Ceiling fansLocation Number Diameter (mm)Kitchen/Living 2 1200Bedroom 1 1 1200

Roof typeConstruction Added

insulationRoof colour

Corrugated Iron Foil, Gap Above,Reflective SideDown, Anti-glareUp

Medium

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0003437837 Certificate Date: 07 Dec 2018 ★ Star rating: 8.4

Building features continued

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 4 of 5

Page 7: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments.

For more details see www.nathers.gov.au

Certificate Date:

Explanatory notes

Accredited Assessors

To ensure you get a high-quality, professional NatHERS House Energy Rating report, you should always use an

Organisation (AAO).

and continuing professional development requirements to maintain a high and consistent standard of assessments across the country. Non-accredited assessors do not have this level of quality assurance or any on-going training requirements.

concerns, please contact their AAO listed under ‘assessor

Disclaimer

The energy values quoted are for comparison purposes only; they are not a prediction of actual energy use. This rating

the rating.

Contact

For more information on the Nationwide House Energy Rating Scheme (NatHERS), visit www.nathers.gov.au

insulation visit www.yourhome.gov.au

About this report

including heating and cooling, hot water, dishwashers, ovens,

General Information

A NatHERS House Energy Rating is a comprehensive, dynamic computer modelling evaluation of the floorplans, elevations and specifications to predict an energy load of a home. Not all of us use our homes in the same way, so ratings are generated using standard assumptions. This means homes can be compared across the country.

The actual energy consumption of your home may vary significantly from the predicted energy load figures in the report depending on issues such as the size of your household and your personal preferences, e.g. in terms of heating or cooling.

While the figures are an indicative guide to energy use, they can be used as a reliable guide for comparative purposes between different house designs and for demonstrating that the design meets the required regulatory compliance.

Homes that are energy efficient use less energy, are warmer in winter, cooler in summer and cost less to run. The higher the star rating the more energy efficient.

This NatHERS House Energy Rating report was carefully prepared by your assessor on the basis of comprehensive modelling using standard procedures to rate your home using the underlying engine developed by the Australian Commonwealth Scientific and Industrial Research Organisation (CSIRO).

All information relating to energy loads presented in this report is based on a range of standard assumptions in order to allow for comparisons with reports prepared for other homes and to demonstrate minimum regulatory compliance.

The standard assumptions include figures for occupancy, indoor air temperature and are based on a unique climate file for your region.

Additional information

0003437837 07 Dec 2018 8.4

Page 5 of 5

Page 8: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments.For more details see www.nathers.gov.au

Nationwide House Energy Rating Scheme* Certificate Certificate number: Certificate Date: êStar rating:

MJ/m2

Assessor details

Accreditation number: Name: Organisation:Email: Phone: Declaration of interest:

Key construction and insulation materials (see following pages for details)

Construction:

Insulation:

Glazing:

Plan documents

Plan ref/date: Prepared by:

Net floor area (m2)

Conditioned: Unconditioned: Garage: TOTAL:

Annual thermal performance loads (MJ/m2)

Heating: Cooling: TOTAL:

Dwelling details

Street: Suburb: State:

Type:

Lot/DP number:

Postcode:NCC Class:NatHERSclimate zone:

Ceiling penetrations (see following pages for details)

Sealed: Unsealed: TOTAL:**

**NOTE: This total is themaximum number of ceilingpenetrations allowed to aceiling (under a roof) for thiscertificate. If this number isexceded in construction thenthis certificate IS NOT VALIDand a new certificate is required.Loss of ceiling insulation for thepenetrations listed has beentaken into account with the rating.

Principle downlight type:

Window selection - default windows only

Note on allowable window values:Only a 5% tolerance to the nominatedSHGC window values shown on page 2can be used with this rating.

Note: Only a +/- 5% SHGC tolerance is allowed with this rating.

NB: This tolerance ONLY applies to SHGC, the U-value can always be lower but not higher than the values stated on page 2.

If any of windows selected are outside the 5% tolerance then this certificate is no longer valid and the dwelling will need to be rerated to confirm compliance.

Overview

Scan to access this certificate online and confirm this is valid.

Software:

AAO:

Exposure:

07 Dec 20180003437845-01 8.3BERS Pro v4.3.0.0 (3.13) cannot be used to model 'roof windows'. Roof windows are 'openable or fixed windows in a roof' and do not have a shaft, as distinctfrom skylights which incorporate a built-in shaft and are not ventilated. BERS Pro v4.3 can only model skylights. If a roof window is present on the floor planthen this certificate is not valid.

8.3VIC/BDAV/15/1698Marcus GazsikCyber [email protected]

BERS Pro v4.3.0.2d (3.13)

BDAV

34.7Unit 2, CORELLA STREETLOWOODQLD 4311New Dwelling 1A

9157/SP264094 Suburban

121

13Fibro Cavity Panel on BattensCorrugated IronConcrete Slab on GroundReflective wall insulationR2.5 ceiling insulationNo floor insulation

LED

ALM-002-01 A Aluminium B SG Clear

57.07.00.0

63.012.921.834.7

LOT 157 CORELLA STREETAUSTRALIAN FLOOR PLANS

Page 1 of 5

Page 9: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

Window type and performance valueWindow ID Window type U-value SHGCALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70

Window scheduleLocation Window ID Window no. Height (mm) Width (mm) Orientation Outdoor shadeKitchen/Living ALM-002-01 A n/a 2100 1800 SW No ShadingBedroom 2 ALM-002-01 A n/a 1200 1800 SW No ShadingBath ALM-002-01 A n/a 900 1200 SW No ShadingWC ALM-002-01 A n/a 600 600 SW No Shading

Roof window and skylight type and performance valueID Window type U-value SHGCNone Present

Roof window and skylight scheduleLocation ID Roof

window/skylightno.

Area (m²) Orientation Outdoor shade Indoorshade/diffuser

None Present

External wall typeID Wall type Insulation Wall wrap or foilEW-1 Fibro Cavity Panel on Battens Foil, Anti-glare one side, Reflective other Yes

External wall scheduleLocation ID Width (mm) Height (mm) Orientation Fixed Shade Eaves

(mm)Kitchen/Living EW-1 4995 2400 SW No 500Bedroom 1 EW-1 3095 2400 SW No 500Bedroom 1 EW-1 4600 2400 NW No 500Bedroom 2 EW-1 3090 2400 SW No 500Bath EW-1 1890 2400 SW No 500WC EW-1 990 2400 SW No 500

Internal wall typeWall type Area (m²) Insulation Wall wrap or foilIW-1 - Cavity wall, direct fixplasterboard, single gap

45.0 No insulation No

IW-2 - Shaft liner party wall withplaster

45.0 Bulk Insulation both sides of shaft liner R1.5 No

FloorsLocation Construction Area (m²) Sub floor

ventilationAddedinsulation

Covering

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 2 of 5

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0003437845-01 Certificate Date: 07 Dec 2018 ★ Star rating: 8.3

Building features

Page 10: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

Kitchen/Living Concrete Slab on Ground100mm

31.8 None No Insulation Ceramic Tiles8mm

Bedroom 1 Concrete Slab on Ground100mm

14.1 None No Insulation Ceramic Tiles8mm

Bedroom 2 Concrete Slab on Ground100mm

10.7 None No Insulation Ceramic Tiles8mm

Bath Concrete Slab on Ground100mm

5.0 None No Insulation Ceramic Tiles8mm

WC Concrete Slab on Ground100mm

1.6 None No Insulation Ceramic Tiles8mm

Ceiling typeLocation Construction Added

insulationRoof spaceabove

Kitchen/Living Plasterboard Bulk InsulationR2.5

Yes

Bedroom 1 Plasterboard Bulk InsulationR2.5

Yes

Bedroom 2 Plasterboard Bulk InsulationR2.5

Yes

Bath Plasterboard Bulk InsulationR2.5

Yes

WC Plasterboard Bulk InsulationR2.5

Yes

Ceiling penetrationsLocation Number Type Diameter (mm) Sealed/unsealedKitchen/Living 7 Downlights - LED 150 SealedBedroom 1 2 Downlights - LED 150 SealedBedroom 2 1 Downlights - LED 150 SealedBath 1 Downlights - LED 150 SealedBath 1 Exhaust Fans 300 UnsealedWC 1 Downlights - LED 150 Sealed

Ceiling fansLocation Number Diameter (mm)Kitchen/Living 1 1200Bedroom 1 1 1200

Roof typeConstruction Added

insulationRoof colour

Corrugated Iron Foil, Gap Above,Reflective SideDown, Anti-glare

Medium

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0003437845-01 Certificate Date: 07 Dec 2018 ★ Star rating: 8.3

Building features continued

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 3 of 5

Page 11: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

Up

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0003437845-01 Certificate Date: 07 Dec 2018 ★ Star rating: 8.3

Building features continued

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 4 of 5

Page 12: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments.

For more details see www.nathers.gov.au

Certificate Date:

Explanatory notes

Accredited Assessors

To ensure you get a high-quality, professional NatHERS House Energy Rating report, you should always use an

Organisation (AAO).

and continuing professional development requirements to maintain a high and consistent standard of assessments across the country. Non-accredited assessors do not have this level of quality assurance or any on-going training requirements.

concerns, please contact their AAO listed under ‘assessor

Disclaimer

The energy values quoted are for comparison purposes only; they are not a prediction of actual energy use. This rating

the rating.

Contact

For more information on the Nationwide House Energy Rating Scheme (NatHERS), visit www.nathers.gov.au

insulation visit www.yourhome.gov.au

About this report

including heating and cooling, hot water, dishwashers, ovens,

General Information

A NatHERS House Energy Rating is a comprehensive, dynamic computer modelling evaluation of the floorplans, elevations and specifications to predict an energy load of a home. Not all of us use our homes in the same way, so ratings are generated using standard assumptions. This means homes can be compared across the country.

The actual energy consumption of your home may vary significantly from the predicted energy load figures in the report depending on issues such as the size of your household and your personal preferences, e.g. in terms of heating or cooling.

While the figures are an indicative guide to energy use, they can be used as a reliable guide for comparative purposes between different house designs and for demonstrating that the design meets the required regulatory compliance.

Homes that are energy efficient use less energy, are warmer in winter, cooler in summer and cost less to run. The higher the star rating the more energy efficient.

This NatHERS House Energy Rating report was carefully prepared by your assessor on the basis of comprehensive modelling using standard procedures to rate your home using the underlying engine developed by the Australian Commonwealth Scientific and Industrial Research Organisation (CSIRO).

All information relating to energy loads presented in this report is based on a range of standard assumptions in order to allow for comparisons with reports prepared for other homes and to demonstrate minimum regulatory compliance.

The standard assumptions include figures for occupancy, indoor air temperature and are based on a unique climate file for your region.

Additional information

0003437845-01 07 Dec 2018 8.3

Page 5 of 5

Page 13: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

Department of Housing and Public Works

Form 15—Compliance certificate for building design or specification

NOTE: This is to be used for the purposes of section 10 of the Building Act 1975 and/or section 46 of the Building Regulation 2006. RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether building work complies with the BCA or a provision of the Queensland Development Code (QDC). A building certifier (Class B) can not give a certificate regarding QDC boundary clearance and site cover provisions.

1. Property description This section need only be completed if details of street address and property description are applicable. E.g. in the case of (standard/generic) pool design/shell manufacture and/or patio and carport systems this section may not be applicable. The description must identify all land the subject of the application. The lot and plan details (e.g. SP/RP) are shown on title documents or a rates notice. If the plan is not registered by title, provide previous lot and plan details.

Street address (include no., street, suburb/locality and postcode) CORELLA STREET

LOWOOD Postcode 4311 Lot and plan details (attach list if necessary) LOT 157 ON SP264094

In which local government area is the land situated? SOMERSET REGIONAL COUNCIL

2. Description of component/s certified

Clearly describe the extent of work covered by this certificate, e.g. all structural aspects of the steel roof beams.

ENERGY EFFICIENCY

3. Basis of certification Detail the basis for giving the certificate and the extent to which tests, specifications, rules, standards, codes of practice and other publications, were relied upon.

BERS PRO V 4.3

4. Reference documentation Clearly identify any relevant documentation, e.g. numbered structural engineering plans.

Cyber Energy job no 182587 (plans attached from Australian Floor Plans) UNIT 1 TOTAL STAR RATING – 8.4 UNIT 2 TOTAL STAR RATING – 8.3

LOCAL GOVERNMENT USE ONLY Date received

Reference Number/s

Version 4 – July 2017

Page 14: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

5. Building certifier referencenumber

Building certifier reference number

6. Competent person detailsA competent person for building work,means a person who is assessed bythe building certifier for the work ascompetent to practice in an aspect ofthe building and specification design,of the building work because of theindividual’s skill, experience andqualifications in the aspect. Thecompetent person must also beregistered or licensed under a lawapplying in the State to practice theaspect.

If no relevant law requires theindividual to be licensed or registeredto be able to give the help, the certifiermust assess the individual as havingappropriate experience, qualificationsor skills to be able to give the help.

If the chief executive issues anyguidelines for assessing a competentperson, the building certifier must usethe guidelines when assessing theperson.

Name (in full) MARCUS GAZSIK

Company name (if applicable) Contact person

CYBER ENERGY PTY LTD MARCUS GAZSIKPhone no. (business hours) Mobile no. Fax no.07 5559 0990 0429986273

Email [email protected]

Postal addressSuite 24, 1 Mudgeeraba Road

Worongary Postcode 4213

Licence or registration number (if applicable)

BERS Licence – Cert IV in NatHERS Assessment CPP41212, BDAV Member15/1698

7. Signature of competentperson

This certificate must be signed by theindividual assessed by the buildingcertifier as competent.

Signature Date

7th December 2018

The Building Act 1975 is administered by the Department of Housing and Public Works

Page 15: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

G E N E R A L N O T E S

DENOTES LOCATION OF SMOKE DETECTORS(refer electrical layout plans), TO BE HARD WIREDWITH EMERGENCY BACK-UP AND COMPLY WITH AS 3786.

WIND SPEED AS NOMINATED ON BRACING PLAN.

PROVIDE LIFT OFF HINGES TO W.C. OR OPEN OUT DOOR OR MIN 1200mm CLEARANCEFROM DOOR TO PAN.

EXHAUST FANS FROM SANITARY COMPARTMENTSTO BE DUCTED TO THE OUTSIDE AREA OR TO A VENTED ROOF SPACE AND AS PER AS 1668.2

THESE NOTES ARE NEITHER EXHAUSTIVE NORA SUBSTITUTE FOR REGULATIONS STATUTORY REQUIREMENTS, BUILDING PRACTICE ORCONTRACUAL OBLIGATIONS.

ALL CONSTRUCTION MATERIALS SUPPLIED MUSTTAKE INTO ACCOUNT PROXIMITY TO COASTAL OR INDUSTRIAL ENVIRONMENTS, IN ACCORDANCEWITH MANUFACTURERS SPECIFICATIONS.

THESE PLANS ARE PROTECTED BY COPY RIGHTAND ARE THE PROPERTY OF THE AUTHOR.

GENERAL NOTES

DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY.

THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS LEVELS,SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING WORKS OR ORDERINGMATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKSCONFORM TO THE BUILDING CODE OF AUSTRALIA . CURRENT AUSTRALIANSTANDARDS, BUILDING REGULATIONS AND TOWN PLANNING REQUIREMENTS,REPORT ANY DISCREPANCIES TO THIS OFFICE.

ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OFAUSTRALIAN AND THE AUSTRALIAN STANDARDS.

THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL AND CIVILENGINEERING COMPUTIONS AND DRAWINGS.

SOIL CLASSIFICATION - REFER TO STRUCTURAL ENGINEERS SOIL TEST.

ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCEWITH AS 3660.1 2000 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOXINDICATING TYPE OF BARRIER AND REQUIRED PERIODICAL INSPECTIONS.

SAFETY GLAZING TO BE USED IN THE FOLLOWING CASES -i) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOORii) BATHROOMS - WITHIN 2000mm VERTICAL OF THE BATH BASEiii) FULLY GLAZED DOORSiv) SHOWER SCREENSv) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVELvi) WINDOW SIZES ARE NOMINAL ONLU, ACTUAL SIZES WILL VARY

WITH MANUFACTURER, FLASHING ALL ROUND.

STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE AS DETERMINED BY THE RELEVANT AUTHORITY

TILED DECKS OVER LIVABLE AREAS ARE TO BE, IN THE FOLLOWING ORDER OVERTHE FLOOR JOISTS: 19mm COMPRESSED FIBRE CEMENT SHEET, WITH ONE LAYER OFPARCHEM EMERPROOF 750 WITH A SECOND LAYER OF SAND SEED WITH A DFT OF1300 MICRON, INSTALLED TO MANUF.SPECIFICATIONS AND FLOOR TILES OVER ALLCORNERS TO HAVE 20mm MASTIC SEALANT UNDER THE PARCHEM EMERPROOF 750.

FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES OR EASEMENTS. IT ISRECOMMENDED THAT WHERE BUILDINGS ARE TO BE LOCATED IN CLOSE PROXIMITY OF BOUNDRIES, A CHECK SURVEY BE CONDUCTED BY A LICENSED SURVEYOR.

ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.

ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740. SPLASH BACKS SHALL BEIMPERVIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN 75mm OFTHE WALL.

PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL ANDWITHIN 300mm OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL.

SUB-FLOOR VENTILATION MINIMUM 7500mm sq FOR EXTERNAL WALLS AND 1500mm sqFOR INTERNAL WALLS BELOW BEARER.

STAIR REQUIREMENTS : MIN. TREAD 240mm, MIN. RISER 115mm, MAX. RISER 190mm,SPACE BETWEEN OPEN TREADS MAX. 125mm. TREADS TO BE NON SLIP SURFACE.BALUSTRADES: MIN. 1000mm ABOVE LANDINGS WITH MAX. OPENING OF 125mm AND INACCORDANCE WITH BCA 3.9.2.

FOR STAINLESS STEEL BALUSTRADE, REFER TO TABLE 3.9.2.1 (WIRE BALUSTRADECONSTRUCTION-REQUIRED WIRE TENSION AND NAXIMUM PERMISSIBLEDEFLECTION) OF THE BCA.

THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OFEXISTING AND NEW STRUCTURES THROUGH-OUT CONSTRUCTION.

s

LEGEND

CJ CONSTRUCTION JOINTDP DOWNPIPEFP FIRE PLACEFW FLOOR WASTEHWS HOT WATER SYSTEMAC AIR CONDITIONINGPS PLUMBING STACK / DUCTSP STEEL POSTT.B.C. TO BE CONFIRMEDRL RELATIVE LEVELAHD AUSTRALIAN HEIGHT DATUMCSD CAVITY SLIDING DOOROHC OVER HEAD CUPBOARDFG FIXED GLASSFSR FLOOR SPACE RATIOLB LOAD BEARINGNGL NATURAL GROUND LINEUBO UNDER BENCH OVENWO WALL OVENDW DISHWASHERMW MICROWAVEWM WASHING MACHINEWIR WALK-IN-ROBEASD SLIDING GLASS DOORASW ALUMINIUM SLIDING WINDOWADH ALUM. DOUBLE HUNG WINDOWAAW ALUM. AWNING WINDOWALW ALUM. LOUVRE WINDOWBCA BUILDING CODE OF AUSTRALIAAS AUSTRALIAN STANDARDS

SITE NOTES

ALL STORMWATER AND DRAINAGE TO BE IN COMPLIANCE WITHBCA PARTS 3.1.2 & 3.5.2 AS WELL AS AS/NZS 3500.

ENSURE 90mm DIAMETER AGRICULTURAL DRAINS AREPROVIDED TO THE BASE OF ALL CUTS AND RETAINING WALLSAND ARE CONNECTED TO THE STORMWATER SYSTEM VIA SILTPIT/S TO THE RBS REQUIREMENTS.

THE EXTERNAL FINISHED SURFACE SURROUNDING THEBUILDING MUST BE DRAINED TO MOVE SURFACE WATER AWAYFROM THE BUILDING AND GRADE TO PROVIDE A SLOPE NOTLESS THAN 50mm OVER THE FIRST 1000mm FROM THEBUILDING.

THE HEIGHT OF THE OVERFLOW RELIEF GULLY RELATIVE TODRAINAGE FITTINGS AND GROUND LEVEL MUST BE A MINIMUM OF 150mm BELOW THE LOWEST SANITARY FIXTURE.

CONNECT DOWNPIPES TO LEGAL POINT OF DISCHARGE VIA100mm DIAMETER UPVC STORMWATER PIPE LAID WITH AMINIMUM FALL OF 1:80, DISCHARGE TO THE SATISFACTION OFTHE RELEVANT AUTHORITY.

2 DOWNPIPES MAX. TO EACH 100mm STORMWATER PIPE,SUBSURFACE PIPES TO BE 100mm DIAMETER, ANY UNDERSLAB PIPING TO HAVE AN INSPECTION OPENING AT UPPER END, IT ISTO BE 100mm SEWER GRADE PIPING WITH NO JOINS UNDERSLAB.

2450

PITCH LINECEILING LEVEL

FLOOR LEVELGROUND LEVEL

ColourBond metal roofat 15.0º pitch

Selected 21-48 Panel Lift Door

Linea Cladding

90 X 90 Post

Pergola

Timber Screen Timber Screen

E L E V A T I O N 1SCALE: 1: 100 (A3)

AC Cladding

CLIENT :

DATE:

SITE: FloorGaragePorchPergola

DO NOT SCALE OFF. Written dimensions take precedence

SCALE: 1:100

TOTAL BUILDING :WIND SPEED: N3

General notes:

- concrete construction to comply with AS2870 AND AS3600 BCA - steel frame construction to comply with AS1684 -2006.- metal roofing to comply with AS1757 /AS2050- wet areas to comply with the provisions of Part 3.8.1of the bca.- weepholes in masonry walls at 900 ctrs.- glass installation to comply with AS1288 and AS2047.- s denotes smoke detector; smoke alarms to complywith the provisions of Part 3.7.2 of the BCA.

- manhole position approx. only, determine on site.

- provide alcor barrier between lead flashing andzincalume valley gutter as required.

- keep hws 100 clear of walls.- protection of masonry wall ties to comply with the provisions of Part 3.3.3.2 of the BCA.

- protection of lintels in masonry to comply with theprovisions of Part 3.3.3.4 of the BCA.

- mechanical ventilation to internal wc to be ventedto external air via ducting in accordance with the provisions of part 3.8.5.0 of the BCA 1996.

SCALE: 1: 100

Main 3 Bed Unit

LOT 157 CORELLA STREET, LOWOODSP 264094

5/12/18

131.8 m238.0 m24.0 m228.7 m2

Floor2nd Unit

65.5 m2

Sub -Total Sub -Total202.5 m2 110.4 m2

312.9 m2

Rear Pergola 14.0 m2Rear Pergola 30.9 m2

Platinum Australia

Richard Pepi QBCC licence No. 1071125

DRAWN: BUILDER-DESIGNER : Platinum Australia

Page 16: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

ENERGY EFFICIENCY NOTES:

24130

CLIENT :

DATE:

SITE: FloorGaragePorchPergola

DO NOT SCALE OFF. Written dimensions take precedence

SCALE: 1:100

TOTAL BUILDING :WIND SPEED: N3

General notes:

- concrete construction to comply with AS2870 AND AS3600 BCA - steel frame construction to comply with AS1684 -2006.- metal roofing to comply with AS1757 /AS2050- wet areas to comply with the provisions of Part 3.8.1of the bca.- weepholes in masonry walls at 900 ctrs.- glass installation to comply with AS1288 and AS2047.- s denotes smoke detector; smoke alarms to complywith the provisions of Part 3.7.2 of the BCA.

- manhole position approx. only, determine on site.

- provide alcor barrier between lead flashing andzincalume valley gutter as required.

- keep hws 100 clear of walls.- protection of masonry wall ties to comply with the provisions of Part 3.3.3.2 of the BCA.

- protection of lintels in masonry to comply with theprovisions of Part 3.3.3.4 of the BCA.

- mechanical ventilation to internal wc to be ventedto external air via ducting in accordance with the provisions of part 3.8.5.0 of the BCA 1996.

F L O O R P L A NSCALE: 1: 100

Main 3 Bed Unit

CONSTRUCTION NOTES

LEGEND

CJ CONSTRUCTION JOINTDP DOWNPIPEMSD MIRROR SL DOORFW FLOOR WASTEEPS EXPANDED POLYSTYRENE FOAM (EPS) Sandwiched HWS HOT WATER SYSTEMAC AIR CONDITIONINGPS PLUMBING STACK / DUCTSP STEEL POSTT.B.C. TO BE CONFIRMEDRL RELATIVE LEVELAHD AUSTRALIAN HEIGHT DATUMCSD CAVITY SLIDING DOOROHC OVER HEAD CUPBOARDFG FIXED GLASSFSR FLOOR SPACE RATIOLB LOAD BEARINGNGL NATURAL GROUND LINEUBO UNDER BENCH OVENWO WALL OVENDW DISHWASHERMW MICROWAVEWM WASHING MACHINEWIR WALK-IN-ROBEASD SLIDING GLASS DOORASW ALUMINIUM SLIDING WINDOWADH ALUM. DOUBLE HUNG WINDOWAAW ALUM. AWNING WINDOWALW ALUM. LOUVRE WINDOWBCA BUILDING CODE OF AUSTRALIAAS AUSTRALIAN STANDARDS

LOT 157 CORELLA STREET, LOWOODSP 264094

5/12/18

131.8 m238.0 m24.0 m228.7 m2

Floor2nd Unit

65.5 m2

Sub -Total Sub -Total202.5 m2 110.4 m2

312.9 m2

Window ScheduleNumber Qty Floor WidthHeight DescriptionW01 1 15002100 ALUMINIUM SLIDING WINDOW

Door ScheduleNumberD01

Qty Floor WidthHeight1 240021001 21001

ALUMINIUM SLIDING DOORDescription

D02

HINGED INTERNAL DOORD03D04

HINGED EXTERNAL DOOR9 1 8202100

D05 1 2100D06 4 1 2100

2

8202100

D07 2 1 17002100 ROBE VINYL SLIDING DOOR

2

D08 1800

W02 12002

2100 3000 2100 3000 1500 2600 4300

820

RAKED CEILING

RAKED CEILING

21-17 VINYL

21-1

5 AS

W

21-1

5 AS

W

820

12-15 ASW

820

21-17 VINYL

21-04 F

09 -15 ASW

720

820

720

21 -24 ASD

770

09 -1

5 AS

W

770

820

21 -24 ASD

09 -1

5 AS

W

820

6000 4800 950 1800 3000 3000

820

21 -18 ASD 06-06 ASW

770

770

09-12 ASW

820 820

820

21-18 VINYL

12-18 ASW 09-18 ASW

820

21 -1

8 A

SD

820

3090

4490

6370

3000

1695

0

ELEVATIONS

312

4

4400

1910

4000

1695

0

3000

6000

2070

1920

2100

900

3000

900

4400

1320

6000

3410

900

2380

530

2980

530

2310

600

1086

030

0021

0090

0

4400

4400

2310

3000

2790

530

900

280

2910

3090

1700

1810

2310

700

900

2620

1600

530

280

9090

9090

9090

9090

90

90

9028

0

2190 5280 4680 7500 4480

1910 10002100 2100 1910 1000 1500 600 1100 900

4810

2342011260

20370 3050

1800 19101000 1000 1910

909090909090

9090 280

Rear Pergola 14.0 m2Rear Pergola 30.9 m2

Platinum Australia

Richard Pepi QBCC licence No. 1071125

DRAWN: BUILDER-DESIGNER :

1. EXTERNAL WALLS = 90 mm

2. N3 WIND DESIGN SPEED

3. ALL INTERNAL DOORS 204O HT

4. WC DOOR TO HAVE EXTERNAL REMOVABLEHINGES IN ACCORDANCE WITH BCA-3.8.3.3

Platinum Australia

RH

towel rail

W01

W01

W02

15001 ALUMINIUM SLIDING WINDOW

W04

W03 2100 1 4001 FIXED GLASSW04 900 15001 ALUMINIUM SLIDING WINDOW

W03

W02

2

D01 D01

W04

3

W04

D02

1800 ALUMINIUM SLIDING DOOR

W05

W05 900 18001 ALUMINIUM SLIDING WINDOW1

W06

W06 1200 18001 ALUMINIUM SLIDING WINDOW1

W07

W07 900 12001 ALUMINIUM SLIDING WINDOW1

W08

W08 600 6001 ALUMINIUM SLIDING WINDOW1

D02

2

D03

D03

3

D04 D04 D04 D04

D04D04

D04D04

D04

D05

HINGED INTERNAL DOOR720

D05

HINGED INTERNAL DOOR770

D06 D06

D06

D06

D07 D07

ROBE VINYL SLIDING DOOR210012

D08

D0821-18 VINYL

D03

1. ALL SHOWER ROSES TO BE 'AAA' SHOWER ROSES

2. IF WATER PRESSURE T0 BUILDING EXCEEDS 500 kpa.PRESSURE LIMITING DEVICE TO BE INSTALLED.

3. MINIMW 4-STAR WELLS RATED TOILETS TO BE INSTALLED.

4. MINIMW 4-STAR WELLS RATED TAP'WARE FOR

5. KITCHEN SINKS, BATHROOM BASINS & LAUNDRY TROUGHS.

6. 250 LITRE RHEEM HOT WATER SYSTEM (OR SIMILAR)

7. MINIMUM 4-STAR MEPS RATED AIR CONDITIONERSTO BE INSTALLED (IF APPLICABLE)

8. 80% TOTAL ENCLOSED FLOOR AREA TO HAVEENERGY EFFICIENT GLOBES INSTALLED.

9. R1.5 WALL INSULATIONR5.0 CEILING INSULATION

PERGOLA

LOUNGE

KITCHENBED 1

LAUNDRYBED 3

PLAY ROOM / STUDY NOOK

BATH

BED 1BED 2

LOUNGE

KITCHENENTRY

ENTRY

GARAGE

PANTRY

PRIVATE SPACE

DINING

FRL 60/60/60

wm

BATH

WC

LINE

N W.I.R

ENSUITE

ALFRESCO

SCRE

EN

SCRE

EN

PORCH

FRL

60/6

0/60

PERGOLA

PERGOLA

ROBE900

900

shr

RH

towel rail

ROBE

BED 2

FR

12 -15 ASW

900

900

shr

21-1

5 VI

NYL

21-4

8 PA

NEL

LIFT

DO

OR

PERGOLA

FR

P

RH

900

900

shr

towe

l rai

l

wm LIN

LAUNDRY

ROBE

PRIVATE SPACE

PERGOLA

ROBE

CARPORT

MAIN UNIT 1

UNIT 2

ss

s

ss

s

ss

DPDP DP

DPDP

DP

DP TAP

TAP

TAP TAP

Page 17: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

ENERGY EFFICIENCY NOTES:

E L E V A T I O N S

CONSTRUCTION NOTES

LEGEND

CJ CONSTRUCTION JOINTDP DOWNPIPEMSD MIRROR SL DOORFW FLOOR WASTEEPS EXPANDED POLYSTYRENE FOAM (EPS) Sandwiched HWS HOT WATER SYSTEMAC AIR CONDITIONINGPS PLUMBING STACK / DUCTSP STEEL POSTT.B.C. TO BE CONFIRMEDRL RELATIVE LEVELAHD AUSTRALIAN HEIGHT DATUMCSD CAVITY SLIDING DOOROHC OVER HEAD CUPBOARDFG FIXED GLASSFSR FLOOR SPACE RATIOLB LOAD BEARINGNGL NATURAL GROUND LINEUBO UNDER BENCH OVENWO WALL OVENDW DISHWASHERMW MICROWAVEWM WASHING MACHINEWIR WALK-IN-ROBEASD SLIDING GLASS DOORASW ALUMINIUM SLIDING WINDOWADH ALUM. DOUBLE HUNG WINDOWAAW ALUM. AWNING WINDOWALW ALUM. LOUVRE WINDOWBCA BUILDING CODE OF AUSTRALIAAS AUSTRALIAN STANDARDS

1. EXTERNAL WALLS = 90 mm

2. N3 WIND DESIGN SPEED

3. ALL INTERNAL DOORS 204O HT

4. WC DOOR TO HAVE EXTERNAL REMOVABLEHINGES IN ACCORDANCE WITH BCA-3.8.3.3

2450

PITCH LINECEILING LEVEL

FLOOR LEVELGROUND LEVEL

10mm SUPERCEIL TO CEILINGS10mm PLASTERBOARD TO WALLS

COLOURBOND METAL ROOF

MANUFACTURERS SPECS TO BE DESIGNED BY ENGINEERROOF TRUSSES AT 900 CTRS FIXED TO

SLAB AND FOOTINGS TO ENGINEER'S DETAIL.POISONS TO A.S. 3660.1-2000 STANDARDS.

Anticon R5.0 Blanket insulation

Anticon R5.0 Blanket insulation

ColourBond metal roofat 15.0º pitch

aluminium framed slidingglass doors and windows

Selected 21-48 Panel Lift Door

AC Cladding

AC Cladding

Linea Cladding

90 X 90 Post

Pergola

Pergola

Pergola

90 X 90 Post90 X 90 Post

90 X 90 Post

Pergola Pergola

Timber Screen

Timber Screen Timber Screen

Timber Screen

90 X 90 Post

E L E V A T I O N 1SCALE: 1: 100 (A3)

E L E V A T I O N 2SCALE: 1: 100 (A3)

E L E V A T I O N 3SCALE: 1: 100 (A3)

E L E V A T I O N 4SCALE: 1: 100 (A3)

Pergola

AC Cladding

AC Cladding

1. ALL SHOWER ROSES TO BE 'AAA' SHOWER ROSES

2. IF WATER PRESSURE T0 BUILDING EXCEEDS 500 kpa.PRESSURE LIMITING DEVICE TO BE INSTALLED.

3. MINIMW 4-STAR WELLS RATED TOILETS TO BE INSTALLED.

4. MINIMW 4-STAR WELLS RATED TAP'WARE FOR

5. KITCHEN SINKS, BATHROOM BASINS & LAUNDRY TROUGHS.

6. 250 LITRE RHEEM HOT WATER SYSTEM (OR SIMILAR)

7. MINIMUM 4-STAR MEPS RATED AIR CONDITIONERSTO BE INSTALLED (IF APPLICABLE)

8. 80% TOTAL ENCLOSED FLOOR AREA TO HAVEENERGY EFFICIENT GLOBES INSTALLED.

9. R1.5 WALL INSULATIONR5.0 CEILING INSULATION

CLIENT :

DATE:

SITE: FloorGaragePorchPergola

DO NOT SCALE OFF. Written dimensions take precedence

SCALE: 1:100

TOTAL BUILDING :WIND SPEED: N3

General notes:

- concrete construction to comply with AS2870 AND AS3600 BCA - steel frame construction to comply with AS1684 -2006.- metal roofing to comply with AS1757 /AS2050- wet areas to comply with the provisions of Part 3.8.1of the bca.- weepholes in masonry walls at 900 ctrs.- glass installation to comply with AS1288 and AS2047.- s denotes smoke detector; smoke alarms to complywith the provisions of Part 3.7.2 of the BCA.

- manhole position approx. only, determine on site.

- provide alcor barrier between lead flashing andzincalume valley gutter as required.

- keep hws 100 clear of walls.- protection of masonry wall ties to comply with the provisions of Part 3.3.3.2 of the BCA.

- protection of lintels in masonry to comply with theprovisions of Part 3.3.3.4 of the BCA.

- mechanical ventilation to internal wc to be ventedto external air via ducting in accordance with the provisions of part 3.8.5.0 of the BCA 1996.

SCALE: 1: 100

Main 3 Bed Unit

LOT 157 CORELLA STREET, LOWOODSP 264094

5/12/18

131.8 m238.0 m24.0 m228.7 m2

Floor2nd Unit

65.5 m2

Sub -Total Sub -Total202.5 m2 110.4 m2

312.9 m2

Rear Pergola 14.0 m2Rear Pergola 30.9 m2

Platinum Australia

Richard Pepi QBCC licence No. 1071125

DRAWN: BUILDER-DESIGNER : Platinum Australia

Page 18: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

ENERGY EFFICIENCY NOTES:

CLIENT :

DATE:

SITE: FloorGaragePorchPergola

DO NOT SCALE OFF. Written dimensions take precedence

SCALE: 1:100

TOTAL BUILDING :WIND SPEED: N3

General notes:

- concrete construction to comply with AS2870 AND AS3600 BCA - steel frame construction to comply with AS1684 -2006.- metal roofing to comply with AS1757 /AS2050- wet areas to comply with the provisions of Part 3.8.1of the bca.- weepholes in masonry walls at 900 ctrs.- glass installation to comply with AS1288 and AS2047.- s denotes smoke detector; smoke alarms to complywith the provisions of Part 3.7.2 of the BCA.

- manhole position approx. only, determine on site.

- provide alcor barrier between lead flashing andzincalume valley gutter as required.

- keep hws 100 clear of walls.- protection of masonry wall ties to comply with the provisions of Part 3.3.3.2 of the BCA.

- protection of lintels in masonry to comply with theprovisions of Part 3.3.3.4 of the BCA.

- mechanical ventilation to internal wc to be ventedto external air via ducting in accordance with the provisions of part 3.8.5.0 of the BCA 1996.

E L E C T R I C A L SCALE: 1: 100

Main 3 Bed Unit

dble g.p.o. 300 above floor levelsingle g.p.o. 300 above floor level

fluorescent light - 1200 single

light switch 1350 above floor levelfeature ceiling lightwall mounted lightdownlight

meter box

ceiling fanexhaust fan

telephone outlet 1650 above floor

rangehood g.p.o. 1650 a.f.l. if req'dmicrowave g.p.o. 1650 a.f.l. if req'd

telephone outlet 300 above floortelevision outlet

single g.p.o. 1050 above floor level

refridg. g.p.o. 1650 above floor

dble g.p.o. 1050 above floor level

garage d.g.p.o. 1350 above floor vanity d.g.p.o. 1100 above floor

RG

M

PP

H

TV

hot water servicesmoke detector

ceiling fan light

Ethernet datasplit air-conditioning g.p.o.

hws

s

15

CONSTRUCTION NOTES

LEGEND

CJ CONSTRUCTION JOINTDP DOWNPIPEMSD MIRROR SL DOORFW FLOOR WASTEEPS EXPANDED POLYSTYRENE FOAM (EPS) Sandwiched HWS HOT WATER SYSTEMAC AIR CONDITIONINGPS PLUMBING STACK / DUCTSP STEEL POSTT.B.C. TO BE CONFIRMEDRL RELATIVE LEVELAHD AUSTRALIAN HEIGHT DATUMCSD CAVITY SLIDING DOOROHC OVER HEAD CUPBOARDFG FIXED GLASSFSR FLOOR SPACE RATIOLB LOAD BEARINGNGL NATURAL GROUND LINEUBO UNDER BENCH OVENWO WALL OVENDW DISHWASHERMW MICROWAVEWM WASHING MACHINEWIR WALK-IN-ROBEASD SLIDING GLASS DOORASW ALUMINIUM SLIDING WINDOWADH ALUM. DOUBLE HUNG WINDOWAAW ALUM. AWNING WINDOWALW ALUM. LOUVRE WINDOWBCA BUILDING CODE OF AUSTRALIAAS AUSTRALIAN STANDARDS

LOT 157 CORELLA STREET, LOWOODSP 264094

5/12/18

131.8 m238.0 m24.0 m228.7 m2

Floor2nd Unit

65.5 m2

Sub -Total Sub -Total202.5 m2 110.4 m2

312.9 m2

RAKED CEILING

RAKED CEILING

Rear Pergola 14.0 m2Rear Pergola 30.9 m2

Platinum Australia

Richard Pepi QBCC licence No. 1071125

DRAWN: BUILDER-DESIGNER :

1. EXTERNAL WALLS = 90 mm

2. N3 WIND DESIGN SPEED

3. ALL INTERNAL DOORS 204O HT

4. WC DOOR TO HAVE EXTERNAL REMOVABLEHINGES IN ACCORDANCE WITH BCA-3.8.3.3

Platinum Australia

G

R

R

M

H

TV

TV

TVTV

TVP

Phws

hws

1. ALL SHOWER ROSES TO BE 'AAA' SHOWER ROSES

2. IF WATER PRESSURE T0 BUILDING EXCEEDS 500 kpa.PRESSURE LIMITING DEVICE TO BE INSTALLED.

3. MINIMW 4-STAR WELLS RATED TOILETS TO BE INSTALLED.

4. MINIMW 4-STAR WELLS RATED TAP'WARE FOR

5. KITCHEN SINKS, BATHROOM BASINS & LAUNDRY TROUGHS.

6. 250 LITRE RHEEM HOT WATER SYSTEM (OR SIMILAR)

7. MINIMUM 4-STAR MEPS RATED AIR CONDITIONERSTO BE INSTALLED (IF APPLICABLE)

8. 80% TOTAL ENCLOSED FLOOR AREA TO HAVEENERGY EFFICIENT GLOBES INSTALLED.

9. R1.5 WALL INSULATIONR5.0 CEILING INSULATION

PERGOLA

LOUNGE

KITCHENBED 1

LAUNDRYBED 3

PLAY ROOM / STUDY NOOK

BATH

BED 1BED 2

LOUNGE

KITCHENENTRY

ENTRY

GARAGE

PANTRY

PRIVATE SPACE

DINING

FRL 60/60/60

wm

BATH

WC

LINE

N W.I.R

ENSUITE

ALFRESCO

SCRE

EN

SCRE

EN

PORCH

FRL

60/6

0/60

PERGOLA

PERGOLA

ROBE900

900

shr

RH

towel rail

ROBE

BED 2

FR

12 -15 ASW

900

900

shr

21-1

5 VI

NYL

21-4

8 PA

NEL

LIFT

DO

OR

PERGOLA

FR

P

RH

900

900

shr

towe

l rai

l

wm LIN

LAUNDRY

ROBE

PRIVATE SPACE

PERGOLA

ROBE

CARPORT

MAIN UNIT 1

UNIT 2

ss

s

ss

s

ss

DPDP DP

DPDP

DP

DP TAP

TAP

TAP TAP

Page 19: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

CLIENT :

DATE:

SITE: FloorGaragePorchPergola

DO NOT SCALE OFF. Written dimensions take precedence

SCALE: 1:100

TOTAL BUILDING :WIND SPEED: N3

General notes:

- concrete construction to comply with AS2870 AND AS3600 BCA - steel frame construction to comply with AS1684 -2006.- metal roofing to comply with AS1757 /AS2050- wet areas to comply with the provisions of Part 3.8.1of the bca.- weepholes in masonry walls at 900 ctrs.- glass installation to comply with AS1288 and AS2047.- s denotes smoke detector; smoke alarms to complywith the provisions of Part 3.7.2 of the BCA.

- manhole position approx. only, determine on site.

- provide alcor barrier between lead flashing andzincalume valley gutter as required.

- keep hws 100 clear of walls.- protection of masonry wall ties to comply with the provisions of Part 3.3.3.2 of the BCA.

- protection of lintels in masonry to comply with theprovisions of Part 3.3.3.4 of the BCA.

- mechanical ventilation to internal wc to be ventedto external air via ducting in accordance with the provisions of part 3.8.5.0 of the BCA 1996.

SCALE: 1: 100

Main 3 Bed Unit

LOT 157 CORELLA STREET, LOWOODSP 264094

5/12/18

131.8 m238.0 m24.0 m228.7 m2

Floor2nd Unit

65.5 m2

Sub -Total Sub -Total202.5 m2 110.4 m2

312.9 m2

PERGOLA

LOUNGE

KITCHENBED 1

LAUNDRYBED 3

PLAY ROOM / STUDY NOOK

BATH

BED 1BED 2

LOUNGE

KITCHEN

ENTRY

ENTRY

GARAGE

PANTRY

PRIVATE SPACE

DINING

FRL 60/60/60

wm

BATH

WC

LINE

N W.I.R

ENSUITE

ALFRESCO

SCRE

EN

SCRE

EN

PORCH

FRL

60/6

0/60

PERGOLA

PERGOLA

ROBE

RAKED CEILING

RAKED CEILING

900

900

shr

RH

towel rail

ROBE

BED 2

FR

12 -15 ASW

900

900

shr

21-1

5 VI

NYL

21-4

8 PA

NEL

LIFT

DO

OR

PERGOLA

FR

P

RH

900

900

shr

towe

l rai

l

wm LIN

LAUNDRY

ROBE

PRIVATE SPACE

PERGOLA

ROBE

CARPORT

Rear Pergola 14.0 m2Rear Pergola 30.9 m2

Platinum Australia

Richard Pepi QBCC licence No. 1071125

DRAWN: BUILDER-DESIGNER : Platinum Australia

MAIN UNIT 1

UNIT 2

ss

s

ss

s

ss

DPDP DP

DPDP

DP

DP TAP

TAP

TAP TAP

W I N D B R A C I N G

USE THESE DRAWINGS IN CONJUNCTION WITH STELL FRAMEMANUFACTURERS SPECIFICATIONS AND STRUCTURAL ENGINEERSDESIGNS AND DETAILS

STEEL FRAMED DWELLING

A1

0

50.6 kN

51.0 KN

51.0

resistance required

resistance gaineddire

ctio

n b

A2

10 5.10

96.9 KN

92.6 kN

sub total

96.9

total

resistance required

resistance gained

dire

ctio

n a

pane

l

B1

B2

K-Brace

no. o

ff

450 2.2 kN

19

0

wind bracing - N3

K-Brace D-Brace D-Brace

6002.6 kN

and9004.25 kN

12005.10 kN

5.10

2.6

A2-1.2D-Brace

A2-1.2D-Brace

A2-1.2D-Brace

A2-1.2D-Brace

A2-1.2D-Brace

A2-1.2D-Brace

A2-1.2D-Brace

A2-1.2D-Brace

A2-1.2D-Brace

A2-1.2D-Brace A2-1.2

D-Brace

A2-1.2D-Brace

A2-1.2D-Brace

A2-1.2D-Brace

A2-1.2D-Brace

2400

2700

BOTTOM PLATEG550 Z200 STEEL

1200

900

NOTES: STEEL BRACE AS PER STEEL MANUAL

TIE DOWN TO FLOORREFER TIE DOWN NOTES

G550 Z200 STEEL RIBBON PLATE

D BRACEG550 Z200 STEEL TOP PLATE

G550 Z200 STEELSTUDS AT 600 CRS

NOTES: STEEL BRACE AS PER STEEL MANUAL

TIE DOWN TO FLOORREFER TIE DOWN NOTES

BOTTOM PLATEG550 Z200 STEEL

G550 Z200 STEELSTUDS AT 600 CRS

2400

2700

600

450

G550 Z200 STEEL TOP PLATE

G550 Z200 STEEL RIBBON PLATE

K BRACE

A2-1.2D-Brace

A2-1.2D-Brace

A2-1.2D-Brace

A2-1.2D-Brace

D-Br

ace

B2-1

.2

D-Br

ace

B2-1

.2

D-Br

ace

B2-1

.2

D-Br

ace

B2-1

.2

D-Br

ace

B2-1

.2

D-Br

ace

B2-1

.2

D-Br

ace

B2-1

.2

D-Br

ace

B2-1

.2

D-Br

ace

B2-1

.2

D-Br

ace

B2-1

.2

45º orless

bend to side oftop plate (if nec.)fix with 2 nails toside and 3 nailsunder plate.

SPEEDBRACE DETAIL

bracing at (approx). 30º towall top plate when viewed on plan

speedbrace

battens cont.in the areawhereverpossible

SPEEDBRACESPEEDBRACE

SPEEDBRACE

SPEEDBRACE

Page 20: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

& WORKMANSHIP TO COMPLY WITH THEBUILDING CODE OF AUSTRALIA AND THE RELEVANT

ALL CONSTRUCTION METHODS, MATERIALS

STEEL SCHEDULE

AS NOTED ON ELEVATION PLANSAS NOTED ON ELEVATION PLANS

AS NOTED ON ELEVATION PLANS

METAL. SPACED AT 900 CTRSSPACED AT 600 CTRS TO MANUFACTURER'SDESIGN AND SPECIFICATION

STEEL FRAME 0.78mm THICK EXT. WALL & INT. WALLSPACED AT 600 CTRS WITH 1 ROW NOGGINGG550 Z200 75x50x0.75G550 Z200 75x50x0.75G550 Z200 0.75 STUDS AT 600CRS1 ROWG550 Z200 0.75 BOXED STUDS

STANDARD DETAILS

2401 & OVER

TIE DOWN FIXINGS N3

ALL STEEL FRAMING TO COMPLY WITH AS 3623-1999. ALLBRACING AND TIE-DOWN OF FRAMING TO COMPLY WITH AS1170.2-1999.

HD BOLTS- M12x75mm SCREWBOLTS @ MAX 1200CRS.REQ'D AT EACH SIDE OF OPENING & AT EACH END OF BRACE

TRUSSES TO BEAR WITHIN 50mm OF VERTICALS FORLINTEL TOP PLATE. TRUSSES OUTSIDE OF THIS LIMITWILL REQUIRE THE FIXING OF STIFFENING NOGGING.

NOTES: STEEL BRACE AS PER STEEL MANUAL

TIE DOWN TO FLOORREFER TIE DOWN NOTES

BOTTOM PLATEG550 Z200 STEEL

G550 Z200 STEELSTUDS AT 600 CRS

TRADAC MANUAL IN GENERAL REFER TABLE 2.5 NOMINAL FIXINGS FOR STEEL MEMBERS

D BRACE

900

4.25kN

3.30kN

2400

2700

600

450

GENERAL NOTES

G550 Z200 STEEL TOP PLATE

G550 Z200 STEEL RIBBON PLATE

K BRACE

HEIGHT

2700

2400

K BRACE

600450

2.2kN

1.6kN

2.6kN

2.0kN

SUPPORTGIRDERTRUSSES

2400

2700

BOTTOM PLATEG550 Z200 STEEL

TRADAC MANUAL

3 STUDS4 STUDS

GIRDER

CONNECTIONSTRUSSESSTUDS TO PLATES

1200

900

NOTES: STEEL BRACE AS PER STEEL MANUAL

TIE DOWN TO FLOORREFER TIE DOWN NOTES

GENERAL

ROOF PITCH:ROOF TYPE:

ROOF TYPE:

BATTENS:TRUSSES:

WALL FRAMING:

TOP PLATES:BOTTOM PLATE:STUDS:NOGGING:RIBBON PLATE:

MEMBER

TRUSSES:

LINTELS:0000-18001801-2400

PLATES G550 Z200TOPBOTTOMSTUDS G550 Z200COMMON STUD

1501-24000000-1500JAMB

STUDS

2 STUDS

G550 Z200 STEEL RIBBON PLATE

D BRACEG550 Z200 STEEL TOP PLATE

G550 Z200 STEELSTUDS AT 600 CRS

1200

5.10kN

4.00kN

55msq80msq

27msq40msq

0.75 STUD 600CRS1 ROW OF NOGGING

0.75 STUD 600CRS1 ROW OF NOGGING

4 SCREWS 2 SCREWS2 SCREWS2 SCREWS

TILE ROOFSHEET ROOF

600 / 900 600 / 900

STANDARDGUSSETED

75x50x0.7575x50x0.75

2 STUDS 2 STUDS3 STUDS 3 STUDS

TO SPECIFICATION TO SPECIFICATION40msq 20msq

SCALE: 1: 100 (A3)

S T E E LT I E - D O W N

CLIENT :

DATE:

SITE: FloorGaragePorchPergola

DO NOT SCALE OFF. Written dimensions take precedence

SCALE: 1:100

TOTAL BUILDING :WIND SPEED: N3

General notes:

- concrete construction to comply with AS2870 AND AS3600 BCA - steel frame construction to comply with AS1684 -2006.- metal roofing to comply with AS1757 /AS2050- wet areas to comply with the provisions of Part 3.8.1of the bca.- weepholes in masonry walls at 900 ctrs.- glass installation to comply with AS1288 and AS2047.- s denotes smoke detector; smoke alarms to complywith the provisions of Part 3.7.2 of the BCA.

- manhole position approx. only, determine on site.

- provide alcor barrier between lead flashing andzincalume valley gutter as required.

- keep hws 100 clear of walls.- protection of masonry wall ties to comply with the provisions of Part 3.3.3.2 of the BCA.

- protection of lintels in masonry to comply with theprovisions of Part 3.3.3.4 of the BCA.

- mechanical ventilation to internal wc to be ventedto external air via ducting in accordance with the provisions of part 3.8.5.0 of the BCA 1996.

SCALE: 1: 100

Main 3 Bed Unit

LOT 157 CORELLA STREET, LOWOODSP 264094

5/12/18

131.8 m238.0 m24.0 m228.7 m2

Floor2nd Unit

65.5 m2

Sub -Total Sub -Total202.5 m2 110.4 m2

312.9 m2

Rear Pergola 14.0 m2Rear Pergola 30.9 m2

Platinum Australia

Richard Pepi QBCC licence No. 1071125

DRAWN: BUILDER-DESIGNER : Platinum Australia

Page 21: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

CLIENT :

DATE:

SITE: FloorGaragePorchPergola

DO NOT SCALE OFF. Written dimensions take precedence

SCALE: 1:100

TOTAL BUILDING :WIND SPEED: N3

General notes:

- concrete construction to comply with AS2870 AND AS3600 BCA - steel frame construction to comply with AS1684 -2006.- metal roofing to comply with AS1757 /AS2050- wet areas to comply with the provisions of Part 3.8.1of the bca.- weepholes in masonry walls at 900 ctrs.- glass installation to comply with AS1288 and AS2047.- s denotes smoke detector; smoke alarms to complywith the provisions of Part 3.7.2 of the BCA.

- manhole position approx. only, determine on site.

- provide alcor barrier between lead flashing andzincalume valley gutter as required.

- keep hws 100 clear of walls.- protection of masonry wall ties to comply with the provisions of Part 3.3.3.2 of the BCA.

- protection of lintels in masonry to comply with theprovisions of Part 3.3.3.4 of the BCA.

- mechanical ventilation to internal wc to be ventedto external air via ducting in accordance with the provisions of part 3.8.5.0 of the BCA 1996.

SCALE: 1: 100

Main 3 Bed Unit

LOT 157 CORELLA STREET, LOWOODSP 264094

5/12/18

131.8 m238.0 m24.0 m228.7 m2

Floor2nd Unit

65.5 m2

Sub -Total Sub -Total202.5 m2 110.4 m2

312.9 m2

Rear Pergola 14.0 m2Rear Pergola 30.9 m2

Platinum Australia

Richard Pepi QBCC licence No. 1071125

DRAWN: BUILDER-DESIGNER : Platinum Australia

PORCH

GARAGE

PATIO

PATIO

F O O T I N G & S L A B P L A N

SL82 MESH

50mm bedding sand

approved vapourbarrier slab level

pad level3 N12 BARS BOTTOM

300

DIA

Bored Piers 600 Deep Min into Natural Ground

SLAB THICKENING ( S.T.1. )SCALE: 1: 50 60

0

450

EB1 DENOTES 350w x 450d Edge Beamwith 3/N12 Top & Btm

ST1 DENOTES 300w x 300d Slab Thickeningwith 3/F11TM Btm

BP1 DENOTES 450 dia Mass ConcreteBored Piers 600 Deep Min into Natural Ground

flashing

note: termite protectionto as3660.1

SL82 MESH

STEEL FRAME

50mm bedding sand

approved vapourbarrier slab level

pad level

DIA

3 N12 BARSTOP AND BTM

Bored Piers 600 Deep Min into Natural GroundEDGE BEAM 2 ( E.B.2. )

SCALE: 1: 50

600

450

450

24130

710 6090 14280 3050

24130

44807500468052802190

166607470

1386

0

1386

0

4490

6370

3000

900

2100

600

1920

2250

6090

1086

0

SLOPE 1:150 FALL

SLOPE 1:150 FALL

SLOPE 1:150 FALL

SLOPE 1:150 FALL

SLOPE 1:150 FALL

SLOPE 1:150 FALLBP1IN12 L-BARTOP & BOTTOM600 x 600 LEGS

BEAM CORNER DETAILSCALE: 1: 50

OVERLAPTRENCH MESHFULL WIDTH

2N12 L-BARTOP & BOTTOM600 x 600 LEGS

BEAM T-INTERSECTION DETAILSCALE: 1: 50

OVERLAPTRENCH MESHFULL WIDTH

PROVIDE2N12STARTERBARS FROMSF TO 1B

100 THICK GARAGE SLABSL82 MESH 30 TOP COVER

100 THICK GARAGE SLABSL82 MESH 30 TOP COVER

EB1EB1

EB1 EB1

EB1

EB1

EB1

BP1 BP1BP1

BP1BP1

BP1 BP1

BP1 BP1BP1

BP1BP1

BP1

BP1BP1

BP1

ST1

ST1

ST1

ST1

ST1

ST1

ST1

ST1

ST1

ST1

ST1

ST1

ST1

50 mm STEP DOWN

50 mm STEP DOWN

50 mm STEP DOWN

Page 22: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

1. SCRAPE AWAY VEGETATION & CUT & FILLTO PROVIDE A LEVEL BUILDING PLATFORM.

2. FLOOR SLAB TO BE IN ACCORDANCE WITHENGINEERS DRAWINGS & DETAILS.

3. TERMITE PROTECTION IS A VISUAL BARRIER SYSTEM WITH APPROVED COLLARS AT PENETRATIONS IN ACCORDANCE WITH AS.3600.1 - 2000

4. THIS SITE PLAN IS A TRANSCRIPTION OF THEORIGINAL CONTOUR SURVEY & THE BUILDER IS TO VERIFY ALL INFORMATION CONTAINEDHEREON PRIOR TO SITE START.

5. THE DRIVEWAY & PATH SHOWN ON PLAN IS THESUGGESTED LAYOUT - AREA AS SHOWN ON PLAN.

1. Services have been plotted from records of relevant authorities where available. Prior to anyexcavation or construction on site, the relevantautjority should be contacted for possible locationof further underground services.2. All household sewerage and waste to bedischarged to sewer system.3. Stormwater & roof water to be connected tolegal point of discharge in accordance with Pt3BCA Vol 2 and local authorities requirements.Approval to be obtained from local authority priorto work commencing.4. Grade soil away from perimetre of building toprevent ponding. 1:20 minimum fall. Surface waterto be chanelled to legal point of discharge i.e. yardgully grate or similar.5. Downpipes to be 12m maximum spacing andadjacent to valley intersections.

1. FINISHED SURFACE TO BE GRADED AWAY FROM HOUSE AT MIN. OF 1:20 FOR AT LEAST 1 METRE.

2. SURFACE WATER TO BE CHANNELLED TO COUNCIL STORMWATER DRAINAGE SYSTEM.

3. ROOFWATER TO BE PIPED VIA 100mm DIA.PVC PIPE TO COUNCIL S/WATER DRAINAGE SYSTEM.

4. ROOF & SURFACE WATER TO COMPLY WITH COUNCIL PLUMBING AND DRAINAGE SERVICES CONDITIONS OF APPROVAL.

Approval for legal point of discharge to beobtained from Local Authority prior to workcommencing. Discharge is proposed to:

- Kerb & Channel- Rubble pit to Council requirements- Inter allotment drainage- Stormwater service main- Canal, river- Water tank: Refer to & comply withPart 4 Section 16 of conditions attached

- To council approval ref No.- Other

DOWNPIPES TO BE MAXIMUM 12M SPACING ANDADJACENT TO ALL VALLEY INTERSECTIONS.

DRAINAGE TO BE IN ACCORDANCE WITH PART 3OF THE BCA. POINT OF DISCHARGE TO MEETLOCAL AUTHORITY REQUIREMENTS.

Owner / applicant / builder to ensure no storm water run off.

1. occurs onto adjoining properties.2. occurs back onto any structures.3. is allowed to pond under sub floor areas.

Unhindered flow across these areas must be maintained.

The title boundaries shown hereon were not marked at the time of survey and have been determined by plan dimensions only and not by field survey. Services shown hereon have been located where possible by field survey.

If not able to be so located, services have beenplotted from the records of relevant authorities where available and have been noted accordingly on the plan. Wheresuch records do not exist or are inadequate a notationhas been made hereon.

Prior to any demolition, excavation or construction on the site, the relevant authority should be contacted for possible location of further underground services and detailed locations of all services.

TITLE BOUNDARIES SERVICES DRAINAGE NOTESGENERAL NOTES

S I T E P L A N

CLIENT :

DO NOT SCALE OFF. Written dimensions take precedence

SCALE: 1:200

General notes:

- concrete construction to comply with AS2870 AND AS3600 BCA - steel frame construction to comply with AS1684 -2006.- metal roofing to comply with AS1757 /AS2050- wet areas to comply with the provisions of Part 3.8.1of the bca.- weepholes in masonry walls at 900 ctrs.- glass installation to comply with AS1288 and AS2047.- s denotes smoke detector; smoke alarms to complywith the provisions of Part 3.7.2 of the BCA.

- manhole position approx. only, determine on site.

- provide alcor barrier between lead flashing andzincalume valley gutter as required.

- keep hws 100 clear of walls.- protection of masonry wall ties to comply with the provisions of Part 3.3.3.2 of the BCA.

- protection of lintels in masonry to comply with theprovisions of Part 3.3.3.4 of the BCA.

- mechanical ventilation to internal wc to be ventedto external air via ducting in accordance with the provisions of part 3.8.5.0 of the BCA 1996.

SCALE: 1: 200

STORM WATER RUN OFF

STORMWATER REQUIREMENTS

DOWNPIPES

1. Written dimensions take precedence over scale.2. Builder to verify all boundry clearances and siteset-out dimensions prior to commencement ofconstruction.3. levels & contours are based on assumeddatum. Prior to construction the relevant authorityshould be contacted for possible minimum floorlevel requirements and flood information.4. This site plan is based on a disclosure plan.Therefore the floor level is subject to change.Additional site survey must be taken to confirmthe required bench level.5. Retaining walls greater than 1m high (cut or fill)are required to be engineer designed & certified prior to building approval. Retaining walls are closer than1500mm from boundary require a building relaxation(fill side only).6. Batters to comply appropriate soil classficationdescribed in table 3.1.1.1. BCA Vol 2.7. Engineer to provide design to address footingsif built in close proximity to sewer, stormwater oreasements.8. Vehicular cross-over to be constructed as perlocal council requirements and/or approval.9. Driveways, paths & patios to have exposedaggregate finish unless otherwise noted.

SITE NOTES

SITE:

WIND SPEED: N3

DATE:

FloorGaragePorchPergola

TOTAL BUILDING :

Main 3 Bed Unit

LOT 157 CORELLA STREET, LOWOODSP 264094

5/12/18

131.8 m238.0 m24.0 m228.7 m2

Floor2nd Unit

65.5 m2

Sub -Total Sub -Total202.5 m2 110.4 m2

312.9 m2

Rear Pergola 14.0 m2Rear Pergola 30.9 m2

Platinum Australia

Richard Pepi QBCC licence No. 1071125

DRAWN: BUILDER-DESIGNER : Platinum Australia

C O

R E

L L

A

S T

R E

E T

SITE AREA: 807.0 m2FLOOR : 312.9 m2 ( 38.77 %)

N

6000

3590

PERGOLA

LOUNGE

KITCHENBED 1

LAUNDRYBED 3

PLAY ROOM / STUDY NOOK

BATH

BED 1BED 2

LOUNGE

KITCHENENTRY

ENTRY

GARAGE

PANTRY

PRIVATE SPACE

DINING

FRL 60/60/60

wm

BATH

WC

LINE

N W.I.R

ENSUITE

ALFRESCO

SCRE

EN

SCRE

EN

PORCH

FRL

60/6

0/60

PERGOLA

PERGOLA

ROBE

RAKED CEILING

RAKED CEILING

900

900

shr

RH

towel rail

ROBE

BED 2

FR

12 -15 ASW

900

900

shr

21-1

5 VI

NYL

21-4

8 PA

NEL

LIFT

DO

OR

PERGOLA

FR

P

RH

900

900

shr

towe

l rai

l

wm LIN

LAUNDRY

ROBE

PRIVATE SPACE

PERGOLA

ROBE

CARPORT

MAIN UNIT 1

UNIT 2

ss

s

ss

s

ss

DPDP DP

DPDP

DP

DP TAP

TAP

TAP TAP

STORM WATER

STORM WATER

DRIVEWAY

EXPOSEDAGG

3000

Page 23: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

SEDIMENT FENCE DETAILSMATERIALSFABRIC: POLYPROPYLENE, POLYAMIDE,NYLON, POLYESTER, OR POLYETHYLENEWOVEN OR NON-WOVEN FABRIC, AT LEAST700mm IN WIDTH AND A MINIMUM UNIT WEIGHTOF 140GSM. ALL FABRICS TO CONTAINULTRAVIOLET INHIBITORS AND STABILISERSTO PROVIDE A MINIMUM OF 6 MONTHS OFUSEABLE CONSTRUCTION LIFE (ULTRAVIOLETSTABILITY EXCEEDING 70%)

FABRIC REINFORCEMENT: WIRE OR STEELMESH MINIMUM 14-GAUGE WITH A MAXIMUMMESH SPACING OF 200mm

SUPPORT POSTS/STAKES: 1500mm2 (MIN)HARDWOOD, 2500mm2 (MIN) SOFTWOOD, OR1.5kg/m (MIN) STEEL STAR PICKETS SUITABLEFOR ATTACHING FABRIC.

INSTALLATION

1. REFER TO APPROVED PLANS FOR LOCATION,EXTENT, AND REQUIRED TYPE OF FABRIC (IFSPECIFIED). IF THERE ARE QUESTIONS ORPROBLEMS WITH THE LOCATION, EXTENT,FABRIC TYPE, OR METHOD OF INSTALLATIONCONTACT THE ENGINEER OR RESPONSIBLEON-SITE OFFICER FOR ASSISTANCE.

2. TO THE MAXIMUM DEGREE PRACTICAL, ANDWHERE THE PLANS ALLOW, ENSURE THEFENCE IS LOCATED:(i) TOTALLY WITHIN THE PROPERTYBOUNDARIES;(ii) ALONG A LINE OF CONSTANT ELEVATIONWHEREVER PRACTICAL;(iii) AT LEAST 2m FROM THE TOE OF ANYFILLING OPERATIONS THAT MAY RESULT INSHIFTING SOIL/FILL DAMAGING THE FENCE.

3. INSTALL RETURNS WITHIN THE FENCE ATMAXIMUM 20m INTERVALS IF THE FENCE ISINSTALLED ALONG THE CONTOUR, OR 5 TO10m MAXIMUM SPACING (DEPENDING ONSLOPE) IF THE FENCE IS INSTALLED AT ANANGLE TO THE CONTOUR. THE ‘RETURNS’SHALL CONSIST OF EITHER:(i) V-SHAPED SECTION EXTENDING AT LEAST1.5m UP THE SLOPE; OR(ii) SANDBAG OR ROCK/AGGREGATE CHECK DAM A MINIMUM 1/3 AND MAXIMUM 1/2 FENCE HEIGHT, AND EXTENDING AT LEAST 1.5m UP THE SLOPE.

4. ENSURE THE EXTREME ENDS OF THEFENCE ARE TURNED UP THE SLOPE AT LEAST1.5m, OR AS NECESSARY, TO MINIMISE WATERBYPASSING AROUND THE FENCE.

5. ENSURE THE SEDIMENT FENCE ISINSTALLED IN A MANNER THAT AVOIDS THECONCENTRATION OF FLOW ALONG THEFENCE, AND THE UNDESIRABLE DISCHARGEOF WATER AROUND THE ENDS OF THE FENCE.

6. IF THE SEDIMENT FENCE IS TO BEINSTALLED ALONG THE EDGE OF EXISTINGTREES, ENSURE CARE IS TAKEN TO PROTECTTHE TREES AND THEIR ROOT SYSTEMSDURING INSTALLATION OF THE FENCE. DONOT ATTACH THE FABRIC TO THE TREES.

7. UNLESS DIRECTED BY THE SITESUPERVISOR OR THE APPROVED PLANS,EXCAVATE A 200mm WIDE BY 200mm DEEPTRENCH ALONG THE PROPOSED FENCE LINE,PLACING THE EXCAVATED MATERIAL ON THEUP-SLOPE SIDE OF THE TRENCH.

8. ALONG THE LOWER SIDE OF THE TRENCH,APPROPRIATELY SECURE THE STAKES INTOTHE GROUND SPACED NO GREATER THAN 3mIF SUPPORTED BY A TOP SUPPORT WIRE ORWEIR MESH BACKING, OTHERWISE NOGREATER THAN 2m.

9. IF SPECIFIED, SECURELY ATTACH THESUPPORT WIRE OR MESH TO THE UP-SLOPESIDE OF THE STAKES WITH THE MESHEXTENDING AT LEAST 200mm INTO THEEXCAVATED TRENCH. ENSURE THE MESH ANDFABRIC IS ATTACHED TO THE UP-SLOPE SIDEOF THE STAKES EVEN WHEN DIRECTING AFENCE AROUND A CORNER OR SHARPCHANGE OF DIRECTION.

10. WHEREVER POSSIBLE, CONSTRUCT THESEDIMENT FENCE FROM A CONTINUOUS ROLLOF FABRIC. TO JOIN FABRIC EITHER:(i) ATTACH EACH END TO TWO OVERLAPPINGSTAKES WITH THE FABRIC FOLDING AROUNDTHE ASSOCIATED STAKE ONE TURN, AND WITHTHE TWO STAKES TIED TOGETHER WITH WIRE;OR(ii) OVERLAP THE FABRIC TO THE NEXTADJACENT SUPPORT POST.

11. SECURELY ATTACH THE FABRIC TO THESUPPORT POSTS USING 25 X 12.5mm STAPLES,OR TIE WIRE AT MAXIMUM 150mm SPACING.

12. SECURELY ATTACH THE FABRIC TO THESUPPORT WIRE/MESH (IF ANY) AT A MAXIMUMSPACING OF 1m.

13. ENSURE THE COMPLETED SEDIMENTFENCE IS AT LEAST 450mm, BUT NOT MORETHAN 700mm HIGH. IF A SPILL-THOUGH WEIRIS INSTALLED, ENSURE THE CREST OF THEWEIR IS AT LEAST 300mm ABOVE GROUNDLEVEL.

14. BACKFILL THE TRENCH AND TAMP THE FILLTO FIRMLY ANCHOR THE BOTTOM OF THEFABRIC AND MESH TO PREVENT WATER FROMFLOWING UNDER THE FENCE.

ADDITIONAL REQUIREMENTS FOR THEINSTALLATION OF A SPILL-THROUGH WEIR

1. LOCATE THE SPILL-THROUGH WEIR SUCHTHAT THE WEIR CREST WILL BE LOWER THANTHE GROUND LEVEL AT EACH END OF THEFENCE.

2. ENSURE THE CREST OF THESPILL-THROUGH WEIR IS AT LEAST 300mm THEGROUND ELEVATION.

3. SECURELY TIE A HORIZONTAL CROSSMEMBER (WEIR) TO THE SUPPORT POSTS/STAKES EACH SIDE OF THE WEIR. CUT THEFABRIC DOWN THE SIDE OF EACH POST ANDFOLD THE FABRIC OVER THE CROSS MEMBERAND APPROPRIATELY SECURE THE FABRIC.

4. INSTALL A SUITABLE SPLASH PAD AND/ORCHUTE IMMEDIATELY DOWN-SLOPE OF THESPILL-THROUGH WEIR TO CONTROL SOILEROSION AND APPROPRIATELY DISCHARGETHE CONCENTRATED FLOW PASSING OVERTHE WEIR.

MAINTENANCE

1. INSPECT THE SEDIMENT FENCE AT LEASTWEEKLY AND AFTER ANY SIGNIFICANT RAIN.MAKE NECESSARY REPAIRS IMMEDIATELY.

2. REPAIR ANY TORN SECTIONS WITH ACONTINUOUS PIECE OF FABRIC FROM POSTTO POST.

3. WHEN MAKING REPAIRS, ALWAYS RESTORETHE SYSTEM TO ITS ORIGINALCONFIGURATION UNLESS AN AMENDEDLAYOUT IS REQUIRED OR SPECIFIED.

4. IF THE FENCE IS SAGGING BETWEENSTAKES, INSTALL ADDITIONAL SUPPORTPOSTS.

5. REMOVE ACCUMULATED SEDIMENT IF THESEDIMENT DEPOSIT EXCEEDS A DEPTH OF 1/3THE HEIGHT OF THE FENCE.

6. DISPOSE OF SEDIMENT IN A SUITABLEMANNER THAT WILL NOT CAUSE AN EROSIONOR POLLUTION HAZARD.

7. REPLACE THE FABRIC IF THE SERVICE LIFEOF THE EXISTING FABRIC EXCEEDS6-MONTHS.

REMOVAL

1. WHEN DISTURBED AREAS UP-SLOPE OF THESEDIMENT FENCE ARE SUFFICIENTLYSTABILISED TO RESTRAIN EROSION, THEFENCE MUST BE REMOVED.

2. REMOVE MATERIALS AND COLLECTEDSEDIMENT AND DISPOSE OF IN A SUITABLEMANNER THAT WILL NOT CAUSE AN EROSIONOR POLLUTION HAZARD.

3. REHABILITATE/REVEGETATE THEDISTURBED GROUND AS NECESSARY TOMINIMISE THE EROSION HAZARD.

SEDIMENT FENCE DETAILS

CLIENT :

DATE:

SITE: FloorGaragePorchPergola

DO NOT SCALE OFF. Written dimensions take precedence

SCALE: 1:100

TOTAL BUILDING :WIND SPEED: N3

General notes:

- concrete construction to comply with AS2870 AND AS3600 BCA - steel frame construction to comply with AS1684 -2006.- metal roofing to comply with AS1757 /AS2050- wet areas to comply with the provisions of Part 3.8.1of the bca.- weepholes in masonry walls at 900 ctrs.- glass installation to comply with AS1288 and AS2047.- s denotes smoke detector; smoke alarms to complywith the provisions of Part 3.7.2 of the BCA.

- manhole position approx. only, determine on site.

- provide alcor barrier between lead flashing andzincalume valley gutter as required.

- keep hws 100 clear of walls.- protection of masonry wall ties to comply with the provisions of Part 3.3.3.2 of the BCA.

- protection of lintels in masonry to comply with theprovisions of Part 3.3.3.4 of the BCA.

- mechanical ventilation to internal wc to be ventedto external air via ducting in accordance with the provisions of part 3.8.5.0 of the BCA 1996.

SCALE: 1: 100

Main 3 Bed Unit

LOT 157 CORELLA STREET, LOWOODSP 264094

5/12/18

131.8 m238.0 m24.0 m228.7 m2

Floor2nd Unit

65.5 m2

Sub -Total Sub -Total202.5 m2 110.4 m2

312.9 m2

Rear Pergola 14.0 m2Rear Pergola 30.9 m2

Platinum Australia

Richard Pepi QBCC licence No. 1071125

DRAWN: BUILDER-DESIGNER : Platinum Australia

Page 24: Thermal Performance Specifications NatHERS …...Window type and performance value Window ID Window type U-value SHGC ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70 Window

W O R K P L A C E N O T E S

WORKPLACE HEALTH AND SAFETY1. FALLS. SLIPS. TRIPS

3) WORKING AT HEIGHTSDURING CONSTRUCTION

Wherever possible, components for this building should be prefabricated off-site or at ground level tominimise the risk of workers falling more than two metres. However. construction of this building willrequire workers to be working at heights where a fall in excess of two metres is possible and injuryis likely to result from such a fall. The builder should provide a suitable barrier wherever a person isrequired to work in a situation where falling more than two metres is a possibility.

DURING OPERATION OR MAINTENANCE

For houses or other low-rise buildings where scaffolding is appropriate:

Cleaning and maintenance of windows. walls, root or other components of this building will requirepersons to be situated where a fall from a height in excess of two metres is possible. Where thistype of activity is required. scaffolding, ladders or trestles should be used in accordance with relevantcodes of practice, regulations or legislation.

For buildings where scaffold, ladders. trestles are not appropriate:

Cleaning and maintenance of windows, walls, roof or other components of this building will requirepersons to be situated where a fall from a height in excess of two metres is possible. Where thistype of activity is required. scaffolding. fall barriers or Personal Protective Equipment (PPE) should beused in accordance with relevant codes of practice. regulations or legislation.

b) SLIPPERY OR UNEVEN SURFACESFLOOR FINISHES Specified

If ?nishes have been specified by designer. these have been selected to minimise the risk of floors

and paved areas becoming slippery when wet or when walked on with wet shoes/feet. Any changes

to the speci?ed finish should be made in consultation with the designer or. if this is not practical.surfaces with an equivalent or better slip resistance should be chosen.

FLOOR FINISHES By Owner

If designer has not not been involved in the selection of surface finishes. the owner is responsiblefor the selection of surface ?nishes in the pedestrian trafficable areas of this building. Surfaces

should be selected in accordance with AS HB 197:1999 and AS/NZ 4586:2004.

STEPS, LOOSE OBJECTS AND UNEVEN SURFACES

Due to design restrictions for this building. steps and/or ramps are included in the building whichmay be a hazard to workers carrying objects or otherwise occupied. Steps should be clearly markedwith both visual and tactile warning during construction, maintenance. demolition and at all timeswhen the building operates as a workplace.

Building owners and occupiers should monitor the pedestrian access ways and in particular access toareas where maintenance is routinely carried out to ensure that surfaces have not moved or crackedso that they become uneven and present a trip hazard. Spills, loose material. stray objects or anyother matter that may cause a slip or trip hazard should be cleaned or removed from access ways.Contractors should be required to maintain a tidy work site during construction, maintenance ordemolition to reduce the risk of trips and falls in the workplace. Materials for construction ormaintenance should be stored in designated areas away from access ways and work areas.

2. FALLING OBJECTSLOOSE MATERIALS OR SMALL OBJECTS

Construction. maintenance or demolition work on or around this building is likely to involve personsworking above ground level or about floor levels. Where this occurs one or more of the followingmeasures should be taken to avoid objects falling from the area where the work is being carried outOnto persons below.

1. Prevent or restrict access to areas below where the work is being carried out.

2. Provide toeboards to scaffolding or work platforms.

3. Provide protective structure below the work area.

4. Ensure that all persons below the work area have Personal Protective Equipment (PPE).

BUILDING COMPONENTS

During construction, renovation or demolition of this building, parts of the structure including fabricated

steel work. heavy panels and many other components will remain standing prior to or after supportingparts are in place. Contractors should ensure that temporary bracing or other required support is in

place at all times when collapse which may injure persons in the area is a possibility.

Mechanical lifting of materials and components during construction, maintenance or demolition presentsa risk of falling objects. Contractors should ensure that appropriate lifting devices are used. that loadsare properly secured and that access to areas below the load is prevented or restricted.

3. TRAFFIC MANAGEMENT

For building on a major road. narrow road or steeply sloping road:

Parking of vehicles or loading/unloading of vehicles on this roadway may cause a traf?c hazard.During construction. maintenance or demolition of this building designated parking for workers andloading areas should be provided. Trained traf?c management personnel should be responsible for thesupervision of these areas.

For building where on-site loading/unloading is restricted:

Construction of this building will require loading and unloading of materials on the roadway. Deliveriesshould be well planned to avoid congestion of loading areas and trained traf?c management personnelshould be used to supervise loading/unloading areas.

For all buildings:

Busy construction and demolition sites present a risk of collision where deliveries and other traf?c aremoving within the site. A traffic management plan supervised by trained traffic management personnelshould be adopted for the work site.

4. SERVICES

GENERAL

Rupture of services during excavation or other activity creates a variety of risks including releaseof hazardous material. Existing services are located on or ar0und this site. Where known. theseare identi?ed on the plans but the exact location and extent of services may vary from that

indicated. Services should be located using an appropriate service (such as Dial Before You Dig).appropriate excavation practice should be used and. where necessary. specialist contractors shouldbe used.

Locations with undergrOUnd power:

Underground power lines MAY be located in or around this site. All underground power lines mustbe disconnected ar carefully located and adequate warning signs used prior to any construction.maintenance or demolition commencing.

Locations with overhead power lines:

Overhead power lines MAY be near or on this site. These pose a risk of electrocution it struck orapproached by lifting devices or other plant and persons working above ground level. Where thereis a danger of this occurring. power lines should be. where practical. disconnected or relocated.Where this is not practical adequate warning in the form of bright coloured tape 0r signageshould be used or a protectiVe barrier provided.

5. MANUAL TASKS

Components within this design with a mass in excess of 25kg should be lifted by two or moreworkers or by mechanical lifting device. Where this is not practical. suppliers or fabricators shouldbe required to limit the component mass.

All material packaging. building and maintenance components should clearly show the total massof packages and where practical all items should be stored on site in a way which minimisesbending before lifting. Advice should be provided on safe lifting methods in all areas where liftingmay occur. Construction, maintenance and demolition of this building will require the use ofportable tools and equipment.

These should be fully maintained in accordance with manufacturer’s speci?cations and not used

where faulty or (in the case of electrical equipment) not carrying a current electrical safety tag.All safety guards or devices should be regularly checked and Personal Protective Equipment should

be used in accordance with manufacturer's specification.

6. HAZARDOUS SUBSTANCESASBESTOS

For alterations to a building constructed prior to 1990:

If this existing building was constructed prior to:

1990 — it therefore may contain asbestos

1986 - it therefore is likely to contain asbestos either in cladding material or in fire retardantinsulation material. In either case, the builder should check and. if necessary, take appropriateaction before demolishing. cutting. sanding. drilling or otherwise disturbing the existing structure.

POWDERED MATERIALS

Many materials used in the construction of this building can cause harm if inhaled in powderedform. Persons working on or in the building during construction. operational maintenance ordemolition should ensure good ventilation and wear Personal Protective Equipment includingprotection against inhalation while using powdered material or when sanding. drilling. cutting orotherwise disturbing or creating powdered material.

TREATED TIMBER

The design of this building may include provision for the inclusion of treated timber within thestructure. Dust or fumes from this material can be harmful. Persons working on or in the

building during constmction, operational maintenance or demolition should ensure good ventilationand wear Personal Protective Equipment including protection against inhalation of harmful material

when sanding. drilling. cutting or using treated timber in any way that may cause harmfulmaterial to be released. 00 not burn treated timber.

7. CONFINED SPACESEXCAVATION

Construction of this building and some maintenance on the building will require excavation andinstallation of items within excavations. Where practical. installation should be carried out usingmethods which do not require workers to enter the excavation. Where this is not practical.adequate support for the excavated area should be provided to prevent collapse. Warning signsand barriers to prevent accidental or unauthorised

access to all excavations should be provided.

ENCLOSED SPACES

For buildings with small spaces where maintenance or other access may be required:

Some small spaces within this building will require access by construction or maintenanceworkers. The design documentation calls for warning signs and barriers to unauthorised access.These should bemaintained throughout the life of the building. Where workers are required toenter small spaces they should be scheduled so that access is for short periods. Manual liftingand other manual activity should be

restricted in small spaces.

SMALL PLACES

For buildings with enclosed spaces where maintenance or other access may be required:Enclosed spaces within this building may present a risk to persons entering for construction,maintenanceor any other purpose. The design documentation calls for warning signs and barriersto unauthorisedaccess. These should be maintained thmughout the life of the building. Whereworkers are required toenter enclosed spaces. air testing equipment and Personal ProtectiveEquipment should be provided.

VOLATI LE ORGANIC COMPOUNDS

Many types of glue. solvents. spray packs. paints. varnishes and some cleaning materials anddisinfectants have dangerous emissions. Areas where these are used should be kept well ventilatedwhile the material is being used and for a period after installation. Personal Protective Equipmentmayllalso be required. The manufacturer's recommendations for use must be carefully consideredat a times.

SYNTHETIC MINERAL FIBRE

Fibreglass. rockwool. ceramic and other material used for thermal or sound insulation may containsynthetic mineral fibre which may be harmful if inhaled or if it comes in contact with the skin,eyes or other sensitive parts or the body. Personal Protective Equipment including protectionagainst inhalation of harmful material should be used when installing, removing or working near

bulk insulation material.

TIMBER FLOORS

This building may contain timber flows which have an applied ?nish. Areas where finishes areapplied should be kept well ventilated during sanding and application and for a period after

installation. Personal Protective Equipment may also be required. The manufacturer'srecommendations for use must beca refully considered at all times.

8. PUBLIC ACCESS

Public access to construction and demolition sites and to areas under maintenance causes riskto workers and public. Warning signs and seems barriers to unauthorised access should beprovided. Where electrical installations. excavations. plant or loose materials are present theyshould be secured when not fully supervised.

9. OPERATIONAL USE OF BUILDING

RESIDENTIAL BUILDINGSThis building has been designed as a residential building. If it. at a later date. it is used orintended to be used as a workplace, the provisions of the Work Health and Safety Act 2011 or

subsequent replacement Act should be applied to the new use.

10. OTHER HIGH RISK ACTIVITY

All electrical work should be carried out in accordance with Code of Practice: Managing Electrical

Risks at the Warkplace, AS/NZ 3012 and all licensing requirements.

All work using Plant should be carried out in accordance with Code of Practice: Managing Risksof Plant at the Workplace. All work should be carried out in accordance with Code of Practice:Managing Noise and Preventing Hearing Loss at Work.Due to the history of serious incidents it isrecommended that particular care be exercised when undertaking work involving steelconstruction and concrete placement. All the above applies.

THESE NOTES MUST BE READ ANDUNDERSTOOD BY ALL INVOLVED IN THEPROJECT.

THIS INCLUDES (but is not excluded to)OWNER, BUILDER, SUB—CONTRACTORS,CONSULTANTS, RENOVATORS,OPERATORS, MAINTAINERS, DEMOUSHERS.

THESE NOTES MUST BE READ ANDUNDERSTOOD BY ALL INVOLVED IN THEPROJECT.

THIS INCLUDES (but is not excluded to)OWNER, BUILDER, SUB—CONTRACTORS,CONSULTANTS, RENOVATORS,OPERATORS, MAINTAINERS, DEMOUSHERS.

CLIENT :

DATE:

SITE: FloorGaragePorchPergola

DO NOT SCALE OFF. Written dimensions take precedence

SCALE: 1:100

TOTAL BUILDING :WIND SPEED: N3

General notes:

- concrete construction to comply with AS2870 AND AS3600 BCA - steel frame construction to comply with AS1684 -2006.- metal roofing to comply with AS1757 /AS2050- wet areas to comply with the provisions of Part 3.8.1of the bca.- weepholes in masonry walls at 900 ctrs.- glass installation to comply with AS1288 and AS2047.- s denotes smoke detector; smoke alarms to complywith the provisions of Part 3.7.2 of the BCA.

- manhole position approx. only, determine on site.

- provide alcor barrier between lead flashing andzincalume valley gutter as required.

- keep hws 100 clear of walls.- protection of masonry wall ties to comply with the provisions of Part 3.3.3.2 of the BCA.

- protection of lintels in masonry to comply with theprovisions of Part 3.3.3.4 of the BCA.

- mechanical ventilation to internal wc to be ventedto external air via ducting in accordance with the provisions of part 3.8.5.0 of the BCA 1996.

SCALE: 1: 100

Main 3 Bed Unit

LOT 157 CORELLA STREET, LOWOODSP 264094

5/12/18

131.8 m238.0 m24.0 m228.7 m2

Floor2nd Unit

65.5 m2

Sub -Total Sub -Total202.5 m2 110.4 m2

312.9 m2

Rear Pergola 14.0 m2Rear Pergola 30.9 m2

Platinum Australia

Richard Pepi QBCC licence No. 1071125

DRAWN: BUILDER-DESIGNER : Platinum Australia