2
The only family of all-inside devices supported by 15 years of clinical evidence 1 MENISCUS MENDER II Repair System MENISCAL STITCHER Repair System DYONICS Curved PLATINUM Blades FAST-FIX 360 Meniscal Repair System ULTRA FAST-FIX Meniscal Repair System MENISCAL ROOT Repair System WEREWOLF FLOW 50 Wand FIRSTPASS MINI Family of Suture Passers NOVOSTITCH PRO Meniscal Repair System ** ALL TEARS ALL REPAIRS Complete solutions to save the meniscus Ordering information FAST-FIX 360 Reference # Description 72202467 FAST-FIX 360, straight 72202468 FAST-FIX 360, curved 72202469 FAST-FIX 360, reverse curved 72202674 Straight Knot Pusher/Suture Cutter and Slotted Cannula Set, single use 72202675 Curved Knot Pusher/Suture Cutter and Slotted Cannula Set, single use Instrumentation Reference # Description 015186 Meniscal Depth Probe, reusable 014549 45° Diamond Rasp, reusable 014550 90° Diamond Rasp, reusable 7210977 Slotted Cannula, reusable 7209950 Suture Threaders, sterile, box of 10 Learn more at AllTearsAllRepairs.com 1. Smith+Nephew 2019. Evidence Outcomes Reports EO/SPM/FASTFIX/002/v2 and EO/SPM/FASTFIX/003/v2. 2. Smith+Nephew 2010. Biomechanical Performance. 10600596 Rev. A. 3. Smith+Nephew 2015. User Needs Validation. 15000994 Rev:E. (compared to ULTRA FAST-FIX) 4. Briggs KK, Steadman JR, Hay CJ, Hines SL. Lysholm Score and Tegner Activity Level in Individuals With Normal Knees. AJSM.2009;37:898-901. 5. Anderson AF, Irrgang JJ, Kocher MS, et al. The International Knee Documentation Committee Subjective Knee Evaluation Form. AJSM.2006;34(1):128-135. * Based on FAST-FIX 360 sales data from January 2016 through October 2018. **NOVOSTITCH PRO Meniscal Repair System is market cleared and only available in the US and New Zealand. Sports Medicine Smith & Nephew, Inc. 150 Minuteman Road Andover, MA 01810 www.smith-nephew.com T +978 749 1000 US Customer Service: +1 800 343 5717 Trademark of Smith & Nephew. ©2019 Smith & Nephew. All rights reserved. All trademarks acknowledged. Printed in USA. 04745 V3 11/19 The leader in all-inside meniscal repair

Theadel erin all-inside meniscal repair · 2019. 11. 26. · The standard for minimally invasive, all-inside repairs. The FAST-FIX 360 System’s 360° actuation design provides improved

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Theadel erin all-inside meniscal repair · 2019. 11. 26. · The standard for minimally invasive, all-inside repairs. The FAST-FIX 360 System’s 360° actuation design provides improved

The only family of all-inside devices supported by 15 years of clinical evidence1

MENISCUS MENDER II Repair System

MENISCAL STITCHER Repair System

DYONICS◊ Curved PLATINUM Blades

FAST-FIX◊ 360 Meniscal Repair System

ULTRA FAST-FIX Meniscal Repair System

MENISCAL ROOT Repair System

WEREWOLF◊ FLOW 50◊

Wand

FIRSTPASS◊ MINI Family of Suture Passers

NOVOSTITCH◊ PRO Meniscal Repair System **

ALL TEARS ALL REPAIRS Complete solutions to save the meniscus

Ordering information FAST-FIX◊ 360

Reference # Description

72202467 FAST-FIX 360, straight

72202468 FAST-FIX 360, curved

72202469 FAST-FIX 360, reverse curved

72202674 Straight Knot Pusher/Suture Cutter and Slotted Cannula Set, single use

72202675 Curved Knot Pusher/Suture Cutter and Slotted Cannula Set, single use

Instrumentation

Reference # Description

015186 Meniscal Depth Probe, reusable

014549 45° Diamond Rasp, reusable

014550 90° Diamond Rasp, reusable

7210977 Slotted Cannula, reusable

7209950 Suture Threaders, sterile, box of 10

Learn more at AllTearsAllRepairs.com

1. Smith+Nephew 2019. Evidence Outcomes Reports EO/SPM/FASTFIX/002/v2 and EO/SPM/FASTFIX/003/v2. 2. Smith+Nephew 2010. Biomechanical Performance. 10600596 Rev. A. 3. Smith+Nephew 2015. User Needs Validation. 15000994 Rev:E. (compared to ULTRA FAST-FIX) 4. Briggs KK, Steadman JR, Hay CJ, Hines SL. Lysholm Score and Tegner Activity Level in Individuals With Normal Knees. AJSM.2009;37:898-901. 5. Anderson AF, Irrgang JJ, Kocher MS, et al. The International Knee Documentation Committee Subjective Knee Evaluation Form. AJSM.2006;34(1):128-135.

* Based on FAST-FIX 360 sales data from January 2016 through October 2018. **NOVOSTITCH PRO Meniscal Repair System is market cleared and only available in the US and New Zealand.

Sports Medicine Smith & Nephew, Inc.150 Minuteman RoadAndover, MA 01810

www.smith-nephew.comT +978 749 1000US Customer Service: +1 800 343 5717

◊ Trademark of Smith & Nephew. ©2019 Smith & Nephew. All rights reserved. All trademarks acknowledged. Printed in USA. 04745 V3 11/19

The leader in all-inside meniscal repair

Page 2: Theadel erin all-inside meniscal repair · 2019. 11. 26. · The standard for minimally invasive, all-inside repairs. The FAST-FIX 360 System’s 360° actuation design provides improved

The standard for minimally invasive, all-inside repairs.The FAST-FIX◊ 360 System’s 360° actuation design provides improved control,3

enabling you to deploy implants in any hand position – vertically or horizontally on either side of the meniscus – with a fast, smooth, advancing motion. The spring-action design facilitates the advancement of each implant into the capsule and the auditory confirmation assures that implants are deployed. It delivers the strength of a vertical mattress suture stitch without the traditional open incision.2

The FAST-FIX 360 System, available in straight, curved and reverse curved, offers:3

• Small insertion points

• Easy implant deployment

• Enhanced control due to low-profile, stiffer needle shaft

• Strong, reproducible and easy meniscal repair

All-inside FAST-FIX◊ repair is clinically proven to restore healthy knee function1

1999 T-Fix Suture

2001 FAST-FIX Meniscal Repair System

2007 ULTRA-FAST FIX Meniscal Repair System

2011 FAST-FIX 360 Meniscal Repair System

2013 MAT Procedure Indication

2017 MENISCAL ROOT Repair System

2018 FIRSTPASS◊ MINI Suture Passer

2019 NOVOSTITCH◊ PRO Meniscal Repair System**

360° active deployment delivers fast and easy implant deployment at any hand position3

Two suture colors provides greater visibility against the white meniscus

17 gauge needle minimizes disruption to the meniscus3

Low profile implants which enable repositioning

Laser-marked needle tip serves as a quick reference for needle depth penetration

Adjustable depth limiter helps to avoid the neurovascular bundles behind the meniscus

Lysholm score Tegner activity score (TAS) IKDC score

86.6 mean FAST-FIX postoperative score1

91.6 mean score in healthy adults5

0 100

6.3 mean FAST-FIX postoperative score1

5.7 mean score in healthy adults4

0 10

92.8 mean FAST-FIX postoperative score1

94 mean score in healthy adults4

0 100

Treat inferior tears with Reverse Curved The curved and reverse curved devices allow for easy access to tear sites on superior and tibial surfaces of the meniscus. The bevel and orientation of the needle on the reverse curved has been designed to make it easy to pierce the underside of the meniscus with the aim of producing a flat, more desirable repair.

More than 20 years of innovation in meniscal repair

94 6.3 91.692.8 5.7 86.6

FAST-FIX 360 Curved FAST-FIX 360 Reverse Curved

Evenly closed tear and meniscus reduced

Cur

ved

Stra

ight

Rev

erse

Cur

ved

Globally, a FAST-FIX 360 device is sold every 2 minutes*

2mins

86% mean success rate of all-inside FAST-FIX repair1