Form No. S3515-516 Supersedes S3515-1015 Page 1 of 12 Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin Blowers: Move air quietly. Most models feature multispeed blower motors providing airflow adjustment for high and low static operation. Motor overload protection is standard on all models. Air Conditioner Compressor: Scroll Compressors eliminate need for crankcase heater. Standard on all models, except 5-Ton. R-410A Refrigerant: Designed with R-410A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 2010 EPA requirements. Phase Rotation Monitor: Standard on all 3-phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Galvanized 20 Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 1000 hours of salt spray tests per ASTM B117-03. Foil Faced Insulation: Standard on all units. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Electrical Components: Are easily accessible for routine inspection and maintenance through a right side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or toggle disconnect switch. Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. Filter Service Door: Separate service door provides easy access for filter change. Two Inch, MERV 8 Pleated Air Filters: Are standard equipment. Factory or field installed. Condenser Fan and Motor Shroud Assembly: Slides out for easy access. Barometric Fresh Air Damper: Standard on all units. Allows up to 25% outside fresh air. Optional ventilation packages available. Optional Circuit Breakers: Standard on all electric heat versions of single (230/208 volt) and three phase (230/208 volt) equipment. Toggle disconnects are standard on all electric heat versions of three phase (460 volt) equipment. Slope Top: Standard feature for water run-off. Top Rain Flashing: Standard feature on all models. Freezestat: Standard on W72 models. Optional field installed CMC-29 can be used on all other models. The Solair Wall-Mount Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Factory or field installed accessories are available to meet specific job requirements. THE WALL-MOUNT™ AIR CONDITIONERS 10.0 EER, (60HZ) Liquid Line Filter Drier: Standard on all units. Protects system against moisture. Compressor Control Module: Standard on all units. Built-in off- delay timer adjustable from 30 seconds to 5 minutes. 2-minute on-delay if power interrupt. 120-second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. High & Low Pressure Switches are Auto- Reset: Standard on all units. Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Models J18AA to J72AA Right-Side Control Panel Models J18LA to J72LA Left-Side Control Panel 1.5 to 6 Ton (17,000 to 71,000 Btuh) Engineered Features Complies with efficiency requirements of ASHRAE/IESNA 90.1-2013. Certified to ANSI/ARI Standard 390-2003 for SPVU (Single Package Vertical Units). Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL 1995/CSA 22.2 No. 236-05, Fourth Edition. Commercial Product - Not intended for Residential application. GREEN REFRIGERANT R-410A

THE WALL-MOUNT™ AIR CONDITIONERS 10.0 EER, (60HZ)solairhvac.com/assets/PDFs/J18A--J72L.pdf · 10.0 EER, (60HZ) Liquid Line Filter Drier: Standard on all units. Protects system against

Embed Size (px)

Citation preview

Form No. S3515-516Supersedes S3515-1015Page 1 of 12

Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency.

Twin Blowers: Move air quietly. Most models feature multispeed blower motors providing airflow adjustment for high and low static operation. Motor overload protection is standard on all models.

Air Conditioner Compressor: Scroll Compressors eliminate need for crankcase heater. Standard on all models, except 5-Ton.

R-410A Refrigerant: Designed with R-410A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 2010 EPA requirements.

Phase Rotation Monitor: Standard on all 3-phase scroll compressors. Protects against reverse rotation if power supply is not properly connected.

Galvanized 20 Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 1000 hours of salt spray tests per ASTM B117-03.

Foil Faced Insulation: Standard on all units.

Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation.

Electrical Components: Are easily accessible for routine inspection and maintenance through a right side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or toggle disconnect switch.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Filter Service Door: Separate service door provides easy access for filter change.

Two Inch, MERV 8 Pleated Air Filters: Are standard equipment. Factory or field installed.

Condenser Fan and Motor Shroud Assembly: Slides out for easy access.

Barometric Fresh Air Damper: Standard on all units. Allows up to 25% outside fresh air. Optional ventilation packages available.

Optional Circuit Breakers: Standard on all electric heat versions of single (230/208 volt) and three phase (230/208 volt) equipment. Toggle disconnects are standard on all electric heat versions of three phase (460 volt) equipment.

Slope Top: Standard feature for water run-off.

Top Rain Flashing: Standard feature on all models.

Freezestat: Standard on W72 models. Optional field installed CMC-29 can be used on all other models.

The Solair Wall-Mount Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Factory or field installed accessories are available to meet specific job requirements.

THE WALL-MOUNT™ AIR CONDITIONERS 10.0 EER, (60HZ)

Liquid Line Filter Drier: Standard on all units. Protects system against moisture.

Compressor Control Module: Standard on all units. Built-in off-delay timer adjustable from 30 seconds to 5 minutes. 2-minute on-delay if power interrupt. 120-second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay.

High & Low Pressure Switches are Auto-Reset: Standard on all units. Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor.

Models J18AA to J72AA Right-Side Control PanelModels J18LA to J72LA Left-Side Control Panel1.5 to 6 Ton (17,000 to 71,000 Btuh)

Engineered Features

• Complies with efficiency requirements of ASHRAE/IESNA 90.1-2013.• Certified to ANSI/ARI Standard 390-2003 for SPVU (Single Package Vertical Units).• Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL 1995/CSA 22.2 No. 236-05, Fourth Edition.• Commercial Product - Not intended for Residential application.

Green refriGerant

r-410a

Form No. S3515-516Supersedes S3515-1015Page 2 of 12

Capacity is certified in accordance with ANSI/ARI Standard 390-2003. EER = Energy Efficiency Ratio and is certified in accordance with ANSI/ARI Standard 390-2003. All ratings based on fresh air intake being 100% closed (no outside air introduction).

Capacity and Efficiency Ratings

Specifications 1-1/2 Ton through 3 Ton

Specifications 3-1/2 Ton through 6 Ton

Models J18AAJ18LA

J24AAJ24LA

J30AAJ30LA

J36AAJ36LA

J42AAJ42LA

J48AAJ48LA

J60AAJ60LA

J72AAJ72LA

Cooling Capacity BTUH 17,000 24,600 30,000 36,400 41,500 48,000 59,000 71,000

EER 10.00 10.20 10.30 10.00 10.00 10.00 10.00 10.00

MODELS J18AA-AJ18LA-A

J24AA-AJ24LA-A

J24AA-BJ24LA-B

J24AA-CJ24LA-C

J30AA-AJ30LA-A

J30AA-BJ30LA-B

J30AA-CJ30LA-C

J36AA-AJ36LA-A

J36AA-BJ36LA-B

J36AA-CJ36LA-C

Electrical Rating – 60 Hz 230/208 - 1 230/208 - 1 230/208 - 3 460 - 3 230/208 - 1 230/208 - 3 460 - 3 230/208 - 1 230/208 - 3 460 - 3

Operating Voltage Range 197-253 197-253 197-253 414-506 197-253 197-253 414-506 197-253 197-253 414-506

Compressor--Circuit A

Voltage 230/208 230/208 230/208 460 230/208 230/208 460 230/208 230/208 460 Rated Load Amps 6.0/6.8 9.2/10.6 6.0/6.9 4.3 10.5/12.0 6.6/7.5 3.6 13.4/15 9.9/11.1 5.1 Branch Circuit Selection Current

9.0 12.8 8.3 5.1 16.0 10.0 4.7 17.9 13.2 6.0

Lock Rotor Amps 48/48 64/64 58/58 28 77/77 71/71 38 112/112 88/88 44 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll

Fan Motor & Condenser

Fan Motor--HP--RPM 1/5 - 1075 1/5 - 1075 1/5 - 1075 1/5 - 1075 1/5 - 1075 1/5 - 1075 1/5 - 1075 1/5 - 1075 1/5 - 1075 1/5 - 1075 Fan Motor--Amps 1.2 1.2 1.2 0.8 1.5 1.5 0.8 1.5 1.5 0.8 Fan--DIA/CFM 18" - 1800 18" - 1800 18" - 1800 18" - 1800 20" - 2400 20" - 2400 20" - 2400 20" - 2200 20" - 2200 20" - 2200

Blower Motor & Evap.

Blower Motor--HP-RPM-SPD 1/6-1100-2 1/6-1100-1 1/6-1100-1 1/6-1100-1 1/3-1100-2 1/3-1100-2 1/3-1100-2 1/3-1100-2 1/3-1100-2 1/3-1100-2 Blower Motor--Amps 0.8 1.1 1.1 .45 2.0 2.0 1.0 2.0 2.0 1.0 CFM Cooling & E.S.P. w/Filter (Rated-Wet Coil)

600 - .35 800 - .30 800 - .30 800 - .30 1000 - .45 1000 - .45 1000 - .45 1100 - .30 1100 - .30 1100 - .30

Filter Sizes (inches) STD. 16x25x1 16x25x1 16x25x1 16x25x1 16x30x1 16x30x1 16x30x1 16x30x1 16x30x1 16x30x1

Shipping Weight --LBS. 330 320 320 320 360 360 360 385 385 385

+Barometric Fresh Air Damper-Lbs 3.5 3.5 3.5 3.5 4.0 4.0 4.0 4.0 4.0 4.0

+Economizer-Lbs 69.0 69.0 69.0 69.0 75.0 75.0 75.0 75.0 75.0 75.0

MODELS J42AA-AJ42LA-A

J42AA-BJ42LA-B

J42AA-CJ42LA-C

J48AA-AJ48LA-A

J48AA-BJ48LA-B

J48AA-CJ48LA-C

J60AA-AJ60LA-A

J60AA-BJ60LA-B

J60AA-CJ60LA-C

J72AA-AJ72LA-A

J72AA-BJ72LA-B

J72AA-CJ72LA-C

Electrical Rating – 60 Hz 230/208-1 230/208-3 460-3 230/208-1 230/208-3 460-3 230/208-1 230/208-3 460-3 230/208-1 230/208-3 460-3

Operating Voltage Range 197-253 197-253 414-506 197-253 197-253 414-506 197-253 197-253 414-506 197-253 197-253 414-506

Compressor--Circuit A

Voltage 230/208 230/208 460 230/208 230/208 460 230/208 230/208 460 230/208 230/208 460 Rated Load Amps 15.1/16.9 10.4/11.6 5.2 17.3/19.6 11.8/13.3 5.8 21.8/23.2 13.9/14.8 7.4 27.7/30.4 16.9/18.5 8.8 Branch Circuit Selection Current

19.9 13.6 6.1 21.4 14.5 6.3 23.2 14.8 7.4 36.9 22.4 10.6

Lock Rotor Amps 109/109 83.1/83.1 41 135/135 98/98 55 130/130 110/110 55 185/185 149/149 75 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll

Fan Motor & Condenser

Fan Motor--HP--RPM-SPD 1/3-825-2 1/3-825-2 1/3-825-1 1/3-825-2 1/3-825-2 1/3-825-1 1/3-825-2 1/3-825-2 1/3-825-1 1/2-1075-1 1/2-1075-1 3/4-1075-1 Fan Motor--Amps 2.6 2.6 1.3 2.6 2.6 1.3 2.5 2.5 1.3 4.0 4.0 1.7 Fan--DIA/CFM 24" - 2900 24" - 2900 24" - 2900 24" - 3000 24" - 3000 24" - 3000 24" - 3100 24" - 3100 24" - 3100 24" - 4000 24" - 4000 24" - 4000

Blower Motor & Evap.

Blower Motor--HP-RPM-SPD 1/3-985-2 1/3-985-2 1/3-985-2 1/3-985-2 1/3-985-2 1/3-985-2 1/2-1070-2 1/2-1070-2 1/2-1070-2 3/4-1035-2 3/4-1035-2 3/4-1035-2 Blower Motor--Amps 2.3 2.3 1.2 2.3 2.3 1.2 3.5 3.5 2.1 6.3 6.3 1.7 CFM Cooling & E.S.P. w/Filter (Rated-Wet Coil)

1350 - .40 1350 - .40 1350 - .40 1550 - .35 1550 - .35 1550 - .35 1800 - .30 1800 - .30 1800 - .30 2000 - .25 2000 - .25 2000 - .25

Filter Sizes (inches) STD. 20x30x1 20x30x1 20x30x1 20x30x1 20x30x1 20x30x1 20x30x1 20x30x1 20x30x1 20x30x1 20x30x1 20x30x1

Shipping Weight --LBS. 475 475 475 485 485 485 550 550 550 550 550 550

+Barometric Fresh Air Damper-Lbs 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5

+Economizer-Lbs 91.5 91.5 91.5 91.5 91.5 91.5 91.5 91.5 91.5 91.5 91.5 91.5

Form No. S3515-516Supersedes S3515-1015Page 3 of 12

Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages can be built-in at the factory or field-installed at a later date.

Barometric Fresh Air Damper

BAROMETRIC FRESH AIR DAMPER - BFAD STANDARD The barometric fresh air damper is a standard feature on all models. It is installed on the inside of the service door and allows outside ventilation air, up to 25% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes when the blower is off. Adjustable blade stops allow different amounts of outside air to be introduced into the building and can be easily locked closed if required.

ECONOMIZER – WECO Series OPTIONAL The built-in economizer system is internally mounted behind the service door and allows outside ventilation air, up to 100% of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper. The economizer is designed to provide “free cooling” when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor.

Standard Features:• Fully modulating• Honeywell Hi-Torque Actuator• 7" intake hood with filter• Simple single blade design• Positive shut-off with non-stick gaskets• Electronic DB and/or Enthalpy sensors depending upon version• Honeywell JADE electronic economizer module with precision settings and diagnostics• DB or Enthalpy economizer versions available

Ventilation System Packages

MIS-3754

MIS-3757

Economizer

Form No. S3515-516Supersedes S3515-1015Page 4 of 12

Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 75C copper wire. All wiring must conform to the National Electrical Code and all local codes. These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of Table 310 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway.IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized over-current protection and conductor wires in accordance with the National Electrical Code and all local codes.

MODELRated Volts & Phase

No. Field Power

Circuits

Single Circuit Multiple Circuit

Minimum Circuit

Ampacity

Maximum

External Fuse or Ckt. Brkr.

Field Power

Wire Size

Ground

Wire

MinimumCircuit

Ampacity

MaximumExternal Fuse or Ckt. Breaker

Field Power Wire Size

Ground

Wire SizeCkt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C

J18AA-A00,A0ZA05A08A10

230/208-1

1111

16304656

20305060

121086

12101010

J24AA-A00, A0ZA04A05A08A10

230/208-1

11111

2125304656

3030305060

10101086

1010101010

J24AA-B00, B0ZB06

230/208-311

1522

2025

1210

1210

J24AA-C00, C0ZC06

460-311

911

1515

1414

1414

J30AA-A00, A0ZA05A08A10A15

230/208-1

1111

1 or 2

2632475884

3535506090

88864

101010108 58 26 60 30 6 10 10 10

J30AA-B00, B0ZB06B09B15

230/208-3

1111

19243351

20253560

121086

12101010

J30AA-C00, C0ZC06C09C12C15

460-3

11111

912172126

1515202530

1414121010

1414121010

J36AA-A00, A0ZA05A08A10A15

230/208-1

1111

1 or 2

2932475884

3535506090

88864

101010108 58 26 60 30 6 10 10 10

J36AA-B00, B0ZB06B09B15

230/208-3

1111

23243351

30303560

101086

10101010

J36AA-C00, C0ZC06C09C12C15

460-3

1111

1112172126

1515202530

1414121010

1414121010

J42AA-A00, A0ZA05A10A15A20

230/208-1

111

1 or 21 or 2

32325884

110

50506090

125

88642

10101086

5858

2652

6060

3060

66

106

1010

1010

J42AA-B00, B0ZB09B15B18

230/208-3

1111

25335160

35356060

8866

10101010

J42AA-C00, C0ZC09C15

460-3111

121726

152030

141210

141210

J48AA-A00, A0ZA05A10A15A20

230/208-1

111

1 or 21 or 2

34345884

110

50506090

125

88642

10101086

5858

2652

6060

3060

66

106

1010

1010

J48AA-B00, B0ZB09B15B18

230/208-3

1111

26335160

35356060

8866

10101010

J48AA-C00, C0ZC09C15

460-3111

121726

152030

141210

141210

J60AA-A00, A0ZA05A10A15A20

230/208-1

111

1 or 21 or 2

38386086

112

60606090

125

88632

10101086

6060

2652

6060

3060

66

106

1010

1010

J60AA-B00, B0ZB09B15B18

230/208-3

1112

273553N/A

404060N/A

886

N/A

101010N/A 35 28 40 30 8 10 10 10

J60AA-C00, C0ZC09C15

460-3111

141827

202030

121210

121210

J72AA-A00, A0ZA05A10A15A20

230/208-1

11

1 or 21 or 21 or 3

58586288

114

60607090

125

66632

1010886

585858

265252 52

606060

306060 60

666

1066 6

101010

101010 10

J72AA-B00, B0ZB09B15B18

230/208-3

1112

404055N/A

606060N/A

886

N/A

101010N/A 40 28 60 30 8 10 10 10

J72AA-C00, C0ZC09C15

460-3111

181827

252530

101010

101010

Electrical Specifications — J**AA Series (Field Installed Elec. Heat Only)

Form No. S3515-516Supersedes S3515-1015Page 5 of 12

MODELRated Volts & Phase

No. Field Power

Circuits

Single Circuit Dual Circuit

Minimum Circuit

Ampacity

Maximum

External Fuse or Ckt. Brkr.

Field Power

Wire Size

Ground

Wire

MinimumCircuit

Ampacity

MaximumExternal Fuse or Ckt. Breaker

Field Power Wire Size

Ground

Wire SizeCkt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B

J18LA-A00,A0ZA05A08A10

230/208-1

1111

16304656

20305060

121086

12101010

J24LA-A00, A0ZA05A08A10

230/208-1

1111

21304656

30305060

101086

10101010

J24LA-B00, B0ZB06

230/208-311

1522

2025

1210

1210

J24LA-C00, C0ZC06

460-311

911

1515

1414

1414

J30LA-A00, A0ZA05A08A10A15

230/208-1

1111

1 or 2

2632475884

3535506090

88864

101010108 58 26 60 30 6 10 10 10

J30LA-B00, B0ZB09B15

230/208-3111

193351

203560

1286

121010

J30LA-C00, C0ZC09C15

460-3111

91726

152030

141210

141210

J36LA-A00, A0ZA05A10A15

230/208-1

111

1 or 2

29325884

35356090

8864

1010108 58 26 60 30 6 10 10 10

J36LA-B00, B0ZB09B15

230/208-3111

233351

303560

1086

101010

J36LA-C00, C0ZC09C15

460-3111

111726

152030

141210

141210

J42LA-A00, A0ZA05A10A15

230/208-1

111

1 or 2

32325884

50506090

8864

1010108 58 26 60 30 6 10 10 10

J42LA-B00, B0ZB09B15

230/208-3111

253351

353560

886

101010

J42LA-C00, C0ZC09C15

460-3111

121726

152030

141210

141210

J48LA-A00, A0ZA05A10A15

230/208-1

111

1 or 2

34345884

50506090

8864

1010108 58 26 60 30 6 10 10 10

J48LA-B00, B0ZB09B15

230/208-3111

263351

353560

886

101010

J48LA-C00, C0ZC09C15

460-3111

121726

152030

141210

141210

J60LA-A00, A0ZA05A10A15

230/208-1

111

1 or 2

38386086

60606090

8863

1010108 60 26 60 30 6 10 10 10

J60LA-B00, B0ZB09B15

230/208-3111

273553

404060

886

101010

J60LA-C00, C0ZC09C15

460-3111

141827

202030

121210

121210

J72LA-A00, A0ZA05A10A15

230/208-1

11

1 or 21 or 2

58586288

60607090

6663

101088

5858

2652

6060

3060

66

106

1010

1010

J72LA-B00, B0ZB09B15

230/208-3111

404055

606060

886

101010

J72LA-C00, C0ZC09C15

460-3111

181827

252530

101010

101010

Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 75C copper wire. All wiring must conform to the National Electrical Code and all local codes. These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of Table 310 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway.IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized over-current protection and conductor wires in accordance with the National Electrical Code and all local codes.

Electrical Specifications — J**LA Series (Field Installed Elec. Heat Only)

Form No. S3515-516Supersedes S3515-1015Page 6 of 12

Abo

ve d

ata

is w

ith

1"

stan

dard

thr

owaw

ay fi

lter

and

1"

was

habl

e fil

ter.

For

opti

onal

2"

plea

ted

filte

r -

redu

ce E

SP

by

.15

in.

See

ins

talla

tion

ins

truc

tion

s fo

r m

axim

um E

SP

inf

orm

atio

n on

var

ious

KW

app

licat

ion.

Spe

edJ1

8J2

4J3

0J3

6J4

2J4

8J6

0J7

2

Hig

hLo

w

Sin

gle

Hig

h

Low

Hig

h

Low

Hig

hLo

w

Hig

h

Low

Hig

h

Low

Hig

h

Low

ES

P(I

nch

H2

0)

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

Dry

Coi

lW

etC

oil

0.0

10

00

98

57

20

72

01

01

09

75

14

45

13

80

94

09

30

14

00

13

10

96

59

55

19

80

19

40

18

00

17

05

20

00

19

40

17

50

17

00

21

05

20

10

15

40

14

60

22

55

21

55

0.1

96

59

50

70

06

90

96

09

25

13

85

13

20

93

09

20

13

40

12

60

94

09

30

19

05

18

80

17

00

16

40

19

10

18

65

16

75

16

15

20

45

19

60

14

80

13

95

21

85

20

95

0.2

93

59

00

66

56

60

90

58

70

13

05

12

40

92

09

10

12

65

11

85

90

58

90

18

20

17

60

16

15

15

65

18

20

17

70

16

00

15

40

19

70

18

85

14

00

13

15

21

15

20

35

0.3

88

08

45

63

56

25

83

58

00

12

20

11

50

89

58

80

11

80

11

00

86

08

50

17

35

16

65

15

30

14

50

17

20

16

05

15

00

14

25

18

95

18

00

13

00

12

20

20

50

19

70

0.4

79

57

60

59

05

75

75

07

20

11

25

10

55

85

08

30

10

80

10

10

80

07

85

16

15

15

65

14

25

13

50

15

75

15

00

13

75

13

20

18

00

17

00

12

20

11

50

19

85

19

20

0.5

68

06

45

52

05

10

64

06

10

10

20

95

07

85

75

09

70

89

57

05

68

01

51

01

38

01

10

09

80

14

20

11

90

10

75

10

30

17

05

16

05

11

10

10

70

19

25

18

55

Nom

inal

KW

At

24

0V

(1)

At

20

8V

(1)

At

48

0V

(2)

At

46

0V

(2)

Kw

1-P

h A

mps

3-P

h A

mps

Btu

hK

w1

-Ph

Am

ps3

-Ph

Am

psB

tuh

Kw

3-P

h A

mps

Btu

hK

w3

-Ph

Am

psB

tuh

4.0

4.0

16

.71

3,6

52

3.0

01

4.4

10

,23

9

5.0

5.0

20

.81

7,0

65

3.7

51

8.0

12

,79

9

6.0

6.0

14

.42

0,4

78

4.5

01

2.5

15

,35

96

.07

.22

0,4

78

5.5

26

.91

8,8

40

8.0

8.0

33

.32

7,3

04

6.0

02

8.8

20

,47

8

9.0

9.0

21

.73

0,7

17

6.7

51

8.7

23

,03

89

.01

0.8

30

,71

78

.28

10

.42

8,2

60

10

.01

0.0

41

.73

4,1

30

7.5

03

6.1

25

,59

8

15

.01

5.0

62

.53

6.1

51

,19

51

1.2

55

4.1

31

.23

8,3

96

15

.01

8.0

51

,19

51

3.8

01

7.3

47

,09

9

18

.01

8.0

43

.36

1,4

34

13

.50

37

.54

6,0

76

18

.02

1.7

61

,43

41

6.5

62

0.8

56

,51

9

20

.02

0.0

83

.36

8,2

60

15

.00

72

.15

1,1

95

(1)

Thes

e el

ectr

ic h

eate

rs a

re a

vaila

ble

in 2

30

/20

8V

unit

s on

ly.

(2)

Thes

e el

ectr

ic h

eate

rs a

re a

vaila

ble

in 4

80

V un

its

only

.

In

do

or

Blo

wer

Per

form

an

ce (

60 H

z) -

CF

M a

t R

ate

d V

olt

ag

e

Ele

ctri

c H

eat

Ta

ble

- R

efer

to

Ele

ctri

cal

Sp

ecif

ica

tio

ns

for

Av

ail

ab

ilit

y b

y U

nit

Mo

del

F

acto

ry C

onne

cted

Spe

ed.

Form No. S3515-516Supersedes S3515-1015Page 7 of 12

NOTE: Field installed Heater Packages are not approved for use with top supply opening models.

These heater packages approved for use in dehumidification versions with hot gas reheat.

Heater Packages - Field Installed "A" Series Right-Hand Units• Designed for adding Electric Heat to 0 KW Units • ETL US & Canada Listed• Circuit Breaker Standard on 230/208V Models • Toggle Disconnect Standard on 460V Models

AirConditioner

Models

-A00 Models230/208-1

-B00 Models230/208-3

-C00 Models460-3

Heater Model # KW Heater Model # KW Heater Model # KW

J18AAEHWA02-A05BEHW02A-A08BEHWA02A-A10B

58

10N/A N/A

J24AA

EHWA24A-A04BEHWA02-A05BEHW02A-A08BEHWA02A-A10B

458

10

EHWA24-B06B 6 EHWH24B-C06 6

J30AA

EHWA03-A05BEHWA03-A08BEHWA03-A10BEHWA03-A15B

58

1015

EHWA03-B06BEHWA03-B09BEHWA37-B15B

69

15

EHWC03A-C06EHWC03A-C09EHWA03A-C12EHWA03A-C15

69

1215

J36AA

EHWA03-A05BEHWA03-A08BEHWA03-A10BEHWA03-A15B

58

1015

EHW36A-B06BEHWA03-B09BEHWA37-B15B

69

15

EHWC03A-C06EHWC03A-C09EHWA03A-C12EHWA03A-C15

69

1215

J42AAJ48AA

EHW4TA-A05 EHWA05-A10B

EHWA05-A15BEHWA05-A20B

5101520

EHWA05-B09B EHWA05-B15B

EHW4TA-B18

91518

EHW4TA-C09 EHW4TA-C15

915

J60AA

EHW5TA-A05 EHWA05-A10B

EHWA05-A15BEHWA05-A20B

5101520

EHW60A-B09B EHWA05-B15B EHW5TA-B18

91518

EHW4TA-C09 EHW4TA-C15

915

J72AA

EHW5TA-A05EHWA05-A10EHWA05-A15EHWA05-A20

5101520

EHW70A-B09BEHWA05-B15BEHW6TA-B18

91518

EHWA05A-C09EHW4TA-C15

915

AirConditioner

Models

-A00 Models230/208-1

-B00 Models230/208-3

-C00 Models460-3

Heater Model # KW Heater Model # KW Heater Model # KW

J18LAEHWA02A-A05LBEHW02A-A08LBEHWA02-A10LB

58

10N/A N/A

J24LAEHWA02A-A05LBEHW02A-A08LBEHWA02-A10LB

58

10EHWA24-B06LB 6 N/A

J30LA

EHWA03-A05LBEHWA03-A08LBEHWA03-A10LBEHWA03-A15LB

58

1015

EHWA03-B09LBEHWA37-B15LB

915

EHWC03-C09LEHWA03-C15L

915

J36LAEHWA03-A05LBEHWA03-A10LBEHWA03-A15LB

51015

EHWA03-B09LBEHWA37-B15LB

915

EHWC03-C09LEHWA03-C15L

915

J42LAJ48LA

EHW4TA-A05LEHWA05-A10LBEHWA05-A15LB

51015

EHWA05-B09LBEHWA05-B15LB

915

EHW4TA-C09LEHW4TA-C15L

915

J60LAEHW4TA-A05L

EHWA05-A10LBEHWA05-A15LB

51015

EHWA60-B09LBEHWA05-B15LB

91518

EHW4TA-C09LEHW4TA-C15L

915

J72LAEHW6TA-A05LEHWA05-A10LEHWA05-A15L

51015

EHW70A-B09LEHWA05-B15L

915

EHW4TA-C09LEHW4TA-C15L

915

Heater Packages - Field Installed "L" Series Left-Hand Units

Form No. S3515-516Supersedes S3515-1015Page 8 of 12

3"

Side View

High Voltage

Cond.

Electrical

Drain

InletAir

PanelAccessHeater

4° PitchRain Hood

Built In

(Lockable)Access Panel

Disconnect

EntranceElectrical

Low Voltage

Entrance

C. Breaker/

Hood for CRV andECON modelsonly

1.250

H

D

J

C

2.13

A

I

K7.00

MIS-3796

ElectricHeat

Ventilation Air

Front View

Air OutletCondenser

Filter Access Panel

Standardflush ventdoor for non-ERV/CRVEcon.models

1

F

G

W

5.88

Supply Air Opening

ShippingLocation

Return Air OpeningEntrancesElectricalOptional

(Built In)BracketsMountingSide Wall

Top RainFlashing

Bottom InstallationBracketBack View

T

OE

R

S

S

S

S

SM

.44

NQ

B

P

L

Dimensions of J18-72AA Basic Unit for Architectural & Installation Requirements (Nominal)

MODELWIDTH

(W)DEPTH

(D)HEIGHT

(H)SUPPLY RETURN

A B C B E F G I J K L M N O P Q R S T

J18AAJ24AA 33.300 17.125 74.563 7.88 19.88 11.88 19.88 35.00 10.88 29.75 20.56 30.75 32.06 33.25 31.00 2.63 34.13 26.06 10.55 4.19 12.00 9.00

J30AAJ36AA 38.200 17.125 74.563 7.88 27.88 13.88 27.88 40.00 10.88 29.75 17.93 30.75 32.75 33.25 31.00 2.75 39.13 26.75 9.14 4.19 12.00 9.00

J42AAJ48AA 42.075 22.432 84.875 9.88 29.88 15.88 29.88 43.88 13.56 31.66 30.00 32.68 26.94 34.69 32.43 3.37 43.00 23.88 10.00 1.44 16.00 1.88

J60AAJ72AA 42.075 22.432 93.000 9.88 29.88 15.88 29.88 43.88 13.56 37.00 30.00 40.81 35.06 42.81 40.56 3.37 43.00 31.00 10.00 1.44 16.00 10.00

Clearances Required for Service Accessand Adequate Condenser Inlet AirflowMODELS LEFT SIDE RIGHT SIDE

J18AA, J24AA, J30AA, J36AA 15" 20"

J42AA, J48AA, J60AA, J72AA 20" 20"

NOTE: For side-by-side installation of two (2) JA models, there must be 20" between units. This can be reduced to 15" by using a JL model (left side compressor and controls) for the left unit and JA (right side compressor and controls) for right unit.

Minimum Clearances Required to Combustible Materials

MODELS SUPPLY AIR DUCT FIRST THREE FEET CABINET

J18AA, J24AA 0" 0"

J30AA, J36AA 1/4" 0"

J42AA, J48AA, J60AA, J72AA 1/4" 0"

Refer to the Installation Manual for more detailed information.

Not used when WECO Economizers installed. Filter access is through the WECO hood.

Form No. S3515-516Supersedes S3515-1015Page 9 of 12

1.250I

A

C

K

2.13

H

J

NQ

PM

L

OE

.44 W

3"F

G

R

S

S

S

S

S

T

D

B

5.88

Hood for CRV andECON modelsonly

7.000

1

BottomInstallation

(Built In)

Supply Air Opening

MIS-3737

Air Air Outlet

Bracket

Front ViewDrainElectricalEntrance

Entrances

Inlet

Side ViewHigh Voltage

Cond.

Low VoltageElectrical

Back View

Condenser

OptionalElectrical

Entrance

BracketsMountingSide Wall

LocationShippingFlashing

Return Air Opening

Standard flush

Disconnect

ElectricHeat

Top Rain

HeaterAccess

Filter Access Panel

vent door for

Panel

Econ. modelsnon-ERV/CRV

(Lockable)Access Panel

Ventilation Air

C. Breaker/

Built InRain Hood4° Pitch

Dimensions of J18-72LA Basic Unit for Architectural & Installation Requirements (Nominal)

MODELWIDTH

(W)DEPTH

(D)HEIGHT

(H)SUPPLY RETURN

A B C B E F G I J K L M N O P Q R S T

J18LAJ24LA 33.300 17.125 74.563 7.88 19.88 11.88 19.88 35.00 10.88 29.75 20.56 30.75 32.06 33.25 31.00 2.63 34.13 26.06 10.55 4.19 12.00 9.00

J30LAJ36LA 38.200 17.125 74.563 7.88 27.88 13.88 27.88 40.00 10.88 29.75 17.93 30.75 32.75 33.25 31.00 2.75 39.13 26.75 9.14 4.19 12.00 9.00

J42LAJ48LA 42.075 22.432 84.875 9.88 29.88 15.88 29.88 43.88 13.56 31.66 30.00 32.68 26.94 34.69 32.43 3.37 43.00 23.88 10.00 1.44 16.00 1.88

J60LAJ72LA 42.075 22.432 93.000 9.88 29.88 15.88 29.88 43.88 13.56 37.00 30.00 40.81 35.06 42.81 40.56 3.37 43.00 31.00 10.00 1.44 16.00 10.00

Clearances Required for Service Accessand Adequate Condenser Inlet AirflowMODELS LEFT SIDE RIGHT SIDE

J18LA, J24LA, J30LA, J36LA 15" 20"

J42LA, J48LA, J60LA, J70LA 20" 20"

NOTE: For side-by-side installation of two (2) JL models, there must be 20" between units. This can be reduced to 15" by using a JL model (left side compressor and controls) for the left unit and JA (right side compressor and controls) for right unit.

Minimum Clearances Required to Combustible Materials

MODELS SUPPLY AIR DUCT FIRST THREE FEET CABINET

J18LA, J24LA 0" 0"

J30LA, J36LA 1/4" 0"

J42LA, J48LA, J60LA, J70LA 1/4" 0"

Refer to the Installation Manual for more detailed information.

Not used when WECO Economizers installed. Filter access is through the WECO hood.

Form No. S3515-516Supersedes S3515-1015Page 10 of 12

ModelReturn Air(DB/WB)

Cooling Capacity 75°F 80°F 85°F 90°F 95°F 100°F 105°F 110°F 115°F 120°F 125°F

J18

75/62Total Cooling

Sensible Cooling1740013900

1670013700

1620013600

1550013400

1480013200

1430013000

1360012800

1290012500

1230012100

1170011600

1100011000

80/67Total Cooling

Sensible Cooling1850013400

1820013400

1790013400

1750013400

1700013300

1660013200

1600013100

1540012900

1480012600

1410012400

1330012000

85/72Total Cooling

Sensible Cooling2210013800

2130013600

2060013500

1980013300

1890013100

1820012800

1730012500

1640012100

1560011600

1470011200

1370010700

J24

75/62Total Cooling

Sensible Cooling2810022100

2600020600

2410019400

2240018400

2090017600

1980016900

1880016500

1800016200

1730016000

1690016000

1660015900

80/67Total Cooling

Sensible Cooling3000021400

2830020200

2670019200

2530018400

2460017700

2300017200

2210016900

2140016700

2080016600

2040016700

2020017000

85/72Total Cooling

Sensible Cooling3580021900

3310020500

3070019300

2860018300

2670017400

2520016700

2390016100

2280015700

2190015300

2120015100

2080015100

J30

75/62Total Cooling

Sensible Cooling3250024500

3080023600

2910022800

2760022100

2610021400

2490020900

2370020400

2260019900

2150019500

2060019200

1960018900

80/67Total Cooling

Sensible Cooling3470023700

3350023100

3230022600

3120022100

3000021600

2900021200

2790020900

2690020500

2580020300

2490020100

2390019900

85/72Total Cooling

Sensible Cooling4140024300

3920023500

3710022700

3530022000

3340021200

3170020500

3010019900

2860019200

2710018700

2590018200

2460017600

J36

75/62Total Cooling

Sensible Cooling3950029100

3730028100

3520027200

3350026300

3180025600

3040025000

2910024400

2790023900

2690023600

2600023200

2520022900

80/67Total Cooling

Sensible Cooling4210028200

4060027500

3910026900

3780026300

3640025800

3540025400

3430025000

3330024700

3230024500

3150024300

3070024100

85/72Total Cooling

Sensible Cooling5020028900

4750027900

4490027000

4270026100

4060025300

3870024600

3700023900

3550023200

3400022600

3280022000

3160021300

J42

75/62Total Cooling

Sensible Cooling4360034000

4160033200

3970032200

3800031400

3620030600

3450029900

3290029200

3130028600

2980027900

2830027300

2690026700

80/67Total Cooling

Sensible Cooling4650033000

4530032500

4410031900

4290031400

4150030900

4020030400

3880029900

3730029500

3580029000

3430028600

3270028100

85/72Total Cooling

Sensible Cooling5540033800

5300033000

5070032100

4850031200

4610030300

4400029400

4190028500

3970027700

3760026700

3570025900

3370024900

J48

75/62Total Cooling

Sensible Cooling5050038700

4820037800

4600036900

4390035900

4180035100

3990034200

3800033400

3610032500

3440031700

3270031000

3100030100

80/67Total Cooling

Sensible Cooling5390037500

5250037000

5110036500

4960035900

4800035400

4650034800

4480034200

4310033600

4140033000

3960032400

3780031700

85/72Total Cooling

Sensible Cooling6420038400

6140037600

5870036700

5600035700

5330034700

5090033700

4830032600

4590031500

4350030400

4120029300

3890028100

J60

75/62Total Cooling

Sensible Cooling6550049600

6190048200

5840046800

5500045300

5180043900

4880042500

4590041000

4310039600

4050038300

3790036800

3530035300

80/67Total Cooling

Sensible Cooling6990048100

6740047200

6480046300

6220045300

5900044300

5690043200

5420042100

5140040900

4870039800

4590038500

4300037300

85/72Total Cooling

Sensible Cooling8330049300

7880047900

7440046500

7020045000

6610043500

6220041800

5840040100

5470038400

5120036700

4770034800

4420033000

J72

75/62Total Cooling

Sensible Cooling7380055500

7080054000

6780052400

6480051000

6180049500

5900048200

5610046900

5320045600

5040044400

4760043200

4480042000

80/67Total Cooling

Sensible Cooling7880053800

7710052900

7530051900

7320051000

7100050000

6870049100

6620048100

6350047100

6070046200

5770045200

5460044200

85/72Total Cooling

Sensible Cooling9390055100

9010053700

8650052100

8260050700

7890049000

7510047500

7140045800

6760044200

6380042600

6000040800

5620039100

Capacity Multiplier Factors% of Rated Airflow -10 Rated +10

Total BTUHSensible BTUH

0.9750.950

1.01.0

1.021.05

Below 65°F (18.3C), unit requires a factory or field installed low ambient control. Return air temperature.

Cooling Application Data - Outdoor Temperature

Form No. S3515-516Supersedes S3515-1015Page 11 of 12

Ventilation OptionsModels J18AA, J24AA

J18LA, J24LAJ30AA, J36AAJ30LA, J36LA

J42AA, J48AA, J60AA, J72AAJ42LA, J48LA, J60LA, J72LA

DescriptionFactory Installed

Code No.Field Installed

Part No.Factory Installed

Code No.Field Installed

Part No.Factory Installed

Code No.Field Installed

Part No.Barometric Fresh Air Damper - Standard X BFAD-2 X BFAD-3 X BFAD-5Economizer w/Plug, Temp Only (7" Hood) Y WECOPT2-X Y WECOPT3-X Y WECOPT5-XEconomizer w/Plug, Enthalpy (7" Hood) Z WECOPE2-X Z WECOPE3-X Z WECOPE5-X

Air Conditioning Control Modules All Models Except As Noted

HPC LPC CCM LAC ALR SK SK Factory Installed Code Field Installed Part

STD STD STD • • J Factory Only

STD STD STD • Field Installed Only CMC-15

STD STD STD • Field Installed OnlySK111 Except J60 & J72

SK121 J72 OnlySK122 J60 Only

SERIES | | CONTROL MODULES (See Chart Below)

REVISION

VOLTS & PHASE A - 230/208/60/1 B - 230/208/60/3 C - 460/60/3

KW

COLOR OPTIONS X - Beige (Standard)

FILTER OPTIONS P - 2-inch Pleated (MERV 8)

| COIL OPTIONS X - Standard

| SUPPLY AIR OUTLET X - Front (Standard)

NOMINALCAPACITY | 18 - 1½ Ton 24 - 2 Ton 30 - 2½ Ton 36 - 3 Ton 42 - 3½ Ton 48 - 4 Ton 60 - 5 Ton 72 - 6 Ton

J 36 A A A 00 X P X X X J

VENTILATION OPTIONS (See Table Below)

Air Conditioning Wall-Mount Model Nomenclature

For 0KW and circuit breakers (230/208 Volt) or toggle disconnects (460 Volt) applications, insert 0Z in the KW field of the model number. See Pages 4 & 5 for available Factory Installed KW options and Page 7 for Field Installed Heater Packages.

A = Compressor & Controls - Right Side

L = Compressor & Controls - Left Side

STD = Standard equipment for these specified models. HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note . LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note . CCM. Compressor control module has adjustable 30-second to 5-minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be 2-minutes plus 10% of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with 1 retry) for high and/or low pressure controls, and a 2-minute timed bypass for low-pressure control. LAC. Low ambient control permits cooling operation down to 0°F. LAC is fan-cycling control for outdoor fan motor on all models. ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls. SK. PTCR start kit can be used with all -A single phase models. Increases starting torque 2-3x. Not used for -B or -C three phase models. Do not use if SK111 or SK121 is used. SK. Start capacitor & potential relay start kit can be used with all -A single phase models. Increases starting torque 9x. Not used for -B or -C three phase models. Do not use if CMC-15 is used.

Form No. S3515-516Supersedes S3515-1015Page 12 of 12

NOTES

Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.