Upload
haxuyen
View
217
Download
0
Embed Size (px)
Citation preview
Accelerated Vaporization Rate
The New Most Powerful Solution for Accelerated Vaporization
120W High Power
SupremeEnergy Utilization
The Lumenis Pulse™ 120H holmium laser system and the innovative Xpeeda™ D/S/L fiber, form an amazing combination of power & efficiency for minimized vaporization procedure time.
56% 56%
37%
19%
9%
3% 1% 1%
0.75 1 1.5 2 2.5 3 3.5 4 mm
Ener
gy (%
)
Percent of Energy Delivered to Target Tissue vs. Fiber Distance from Tissue (mm)
Lumenis Pulse 120H Superior Laser Urology Platform
Improved vaporization rate: Delivers 120W - the highest holmium power on the market. Superior power generates accelerated vaporization rate.
Improved safety: Pulse reshaping technology, powered by a dedicated footswitch offers enhanced hemostasis.
Improved vision: Delivers 80Hz - the highest holmium repetition rate on the market. Designed for improved vision and smoother ablated area during a procedure.
Minimized fiber-tissue distance allows better energy utilization
Xpeeda Fiber Supreme Energy Utilization
“For Vaporization of the prostate, the Lumenis Pulse™ 120H stands apart from other available technologies and is clearly superior to KTP (GreenLight®* Laser) or TURP’s. Bleeding is minimal, tissue is easier to remove and, as we have experienced, patients can have their catheter removed almost immediately and go home the same day.”Mr. Christof Kastner, M.D., Consultant Urologist, Cambridge University NHS Trust, UK
Better energy utilization: The new Xpeeda side-firing fiber revolutionizes utilization of the holmium power by delivering more energy directly to the tissue, due to the ability to use it in contact with the tissue during the entire procedure.
Easier to use: Vaporization rate can be adjusted through the ability to control the distance of the fiber from the tissue, without having to change the system’s settings.
More durability: The improved durability and innovative design allow the fiber to withstand the high power laser emission of the Lumenis Pulse120H and last the entire procedure.
* GreenLight is a registered trademark of Laserscope Corporation© 2014 All Rights Reserved. The Lumenis Group of Companies. PB-1005553 Rev AS U R G I CA L . lu m eni s .c o m
AMERICAS
San Jose, CA, USAT +1 408 764 3000 +1 877 586 3647F +1 408 764 3999
EMEA
Dreieich Dreieichenhain, GermanyT +49 6103 8335 0 F +49 6103 8335 300Roma (RM), ItalyT +39 06 90 75 230 F +39 06 90 75 269Hertfordshire, UKT +44 20 8736 4110 F +44 20 8736 4119
JAPAN
Tokyo, JapanT +81 3 4431 8300F +81 3 4431 8301
ASIA / PACIFIC
Beijing, ChinaT + 86 10 5737 6677Gurgaon, IndiaT + 91 124 422 07 95Kowloon, Hong KongT + 852 217 428 00 F + 852 272 251 51
Xpeeda Fiber Specifications
Delivery Device Ho:YAG Nd:YAGCompatible wavelength
Total length 310 cm (Fiber length tolerance: ± 20 cm)
Maximum output power 120W 100W
Maximum output energy 2 Joules
Fiber core diameter 550 μm
Maximum output diameter 2.5mm
Minimum working channel diameter 7.5fr
Number of uses Single-use
Sterilization Supplied EtO-sterilized
Components Laser connector, glass fiber, metal cap with line guides, adjustable handle and rigid tubing.
Laser systems compatibility Lumenis Pulse 120H, VersaPulse® PowerSuite™, VesaPulse PowerSuite Dual Wavelength, VersaPulse P20
The Xpeeda D/S/L fiber is intended for use with compatible lasers in surgical procedures involving open, laparoscopic, endoscopic ablation, vaporization, excision, incision and coagulation of soft tissue.
Lumenis Pulse 120H Specifications
Parameter Value Wavelength 2.1 um
Max Optical Power 120 W
Repetition Rate 5-80 Hz
Pulse Energy 0.2-6 J
Aiming Beam Green. 3 intensity settings and blinking mode
Pulse Width Adjustable
Smart Identification System (SIS) YES
Voice confirmation indicating system’s operational status YES
Dual Pedal Footswitch YES
Fiber & Suction Tube Support Arm YES
Integrated Suction Pump YES
Dimensions [W / L / H] 47 x 116 x 105 cm / 18.5’’ x 45.6’’ x 41.3’’
Weight 245 kg / 539 lbs for single phase
Electrical 200-240 VAC, <46 Amp*, 50/60 Hz
Delivery systems Lumenis SIS reusable and single use delivery systems
Warranty One year parts and labor
LASER CLASS 4 / IVHolmium:YAG Laser: 2.1μm, 6J max, 1300μs pulse max
LASER CLASS 3R / IllaDPSS Laser: 532nm, 5mW max, CW
VISIBLE AND INVISIBLE LASER RADIATIONAVOID EYE OR SKIN EXPOSURE TO DIRECTOR SCATTERED RADIATIONCLASS 4 LASER PRODUCT per IEC 60825-1: 2007CLASS IV LASER PRODUCT per 21 CFR 1040.10 AND 1040.11
LB -
1003
2650
_B
except for deviations pursuant to laser Notice No.50dated June 24, 2007