50
The HBE series inserts are suitable for applications with high voltages and current. The inserts can be terminated in a variety of ways: screw, crimp, or “spring” cage clamp. These inserts fit into the HBE Series housings which are now standard with fixed levers. # of Contacts: 6, 10, 16, 24, 32, 48 65

The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

The HBE series inserts are suitable for applications withhigh voltages and current. The inserts can be terminatedin a variety of ways: screw, crimp, or “spring” cageclamp.

These inserts fit into the HBE Series housings which are now standard with fixed levers.

# of Contacts: 6, 10, 16, 24, 32, 48

65

Page 2: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

66

1TECHNICAL DATA: INSERTS

6, 10, 16, 24, 32, 48 (+PE)

VDE: 500V EPIC HBE 6-48 UL: 600V EPIC HBE 6-48CSA: 600V EPIC HBE 6-48 SEV: 400V EPIC HBE 6-48

VDE: 16A EPIC HBE 6-48 UL: 16A EPIC HBE 6-48CSA: 16A EPIC HBE 6-48 SEV: 16A EPIC HBE 6-48

-40ºC to 125ºC

VDE: 500V EPIC HBE 6-48 UL: 600V EPIC HBE 6-48CSA: 600V EPIC HBE 6-48VDE: 16A EPIC HBE 6-48 UL: 16A EPIC HBE 6-48CSA: 16A EPIC HBE 6-4836 kV

Copper alloy, silver platedCopper alloy, silver plated/ gold platedCopper alloy, silver plated100 (higher mating cycles depending on the application)

<2 mOhm<2 mOhm1.5 - 4 mOhm

6, 10, 16, 24, 32, 48VDE: 380V UL: 600VCSA: 600V SEV: 380VVDE: 16A UL: 16ACSA: 16A SEV: 16A32.5 kV-40ºC to 100ºC0.5 - 2.5 mm2Copper alloy, silver plated100 (higher mating cycles depends on the application

AWG20 - 1420 - 1220 - 14

Number of Contacts:

Screw Termination & Crimp Termination:Rated Voltage:

Rated Current:

Temperature Range:

Cage Clamp:Rated Voltage:

Rated Current

Pollution Level:Dimensioning Transient:

Termination Type:Screw Termination:Crimp Termination:Cage Clamp Termination:

Contacts:Screw Termination:Crimp Termination:Cage Clamp TerminationMating Cycles:

Contact Resistance:Screw Termination:Crimp Termination:Cage Clamp termination:

Terminal Block:Number of Contacts:Rated Voltage:

Rated Current:

Pollution Level:Test Voltage:Temperature Range:Screw Termination:Contacts:Mating Cycles:

mm20.5 - 2.5 mm20.5 - 4.0 mm20.5 - 2.5 mm2

Page 3: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

67

1TECHNICAL DATA: DERATING CURVES

HBE SCREW TERMINATED:1.5 mm2 (16 AWG)

HBE SCREW TERMINATED: 2.5 mm2 (14 AWG)

HBE CRIMP TERMINATED: 1.5 mm2 (16 AWG)

HBE CRIMP TERMINATED: 2.5 mm2 (14 AWG)

HBE CAGE CLAMP:1.5 mm2 (16 AWG) HBE CAGE CLAMP: 2.5 mm2 (14 AWG)

HBE TERMINAL BLOCK: 1.5 mm2 (16 AWG)

HBE TERMINAL BLOCK: 2.5 mm2 (14 AWG)

Ambient Temperature (C) Ambient Temperature (C)

Ambient Temperature (ºC) Ambient Temperature (ºC)

Ambient Temperature (ºC) Ambient Temperature (ºC)

Ambient Temperature (ºC) Ambient Temperature (ºC)

Page 4: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

68

1TECHNICAL DATA: HOUSINGS

Specifications:Temperature Range:Protection class:Material:

HBE 6 - 48 EP: Environmentally Protected: aluminum alloy, powder coated (black), locking levers and bolts madeof stainless steel.

For industrial applications in extremely demanding environments with aggressive atmospheres.

NEMA 4X (IP 68)

DIN 43652-40ºC to +125ºCNEMA 4, IP65 HBE 6 -48: aluminum alloy, powder coated

PG NPT METRIC

HBE 6- 48: aluminum alloy, powder coated (grey), locking levers and bolts made of zinc plated steel.

For industrial applications in demanding environments.

PG NPT METRIC

STANDARD GREY COATING (NEMA 4)

BLACK COATING (NEMA 4X)

Page 5: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

69

1TECHNICAL DATA: HOUSINGS

Page 6: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

70

1 PANEL CUT-OUTS FOR PANEL MOUNT BASES

All dimensions are in mm.

HBE 6 Inserts fit into HBE 10 Inserts fit into

HBE 24 Inserts fit into HBE 32 Inserts fit into

HBE 16 Inserts fit into

HBE 48 Inserts fit into

Page 7: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

71

1HBE 6 SCREW & CRIMP TERMINATED INSERTS

SCREW TERMINATED View from Cable Side

Panel Cut-Out

Panel Cut-Out

Contacts Sold Separately

Screw Terminated with wire protectionScrew Terminated without wire protectionCrimp Terminated: Machined

Plug10.190010.190110.1800

Receptacle10.191010.191110.1810

Screwless Cage ClampPlug

10.4000Receptacle

10.4010

HBE 6 SCREWLESS SPRING CAGE CLAMP INSERTS

All dimensions are in mm.

All dimensionsare in mm.

These inserts fit inthe HBE 6 Series

Housings which areon the following

pages.

Same View from Cable Side as Screw & Crimp TerminationThese inserts fit inthe HBE 6 Series

Housings which areon the following

pages.

Crimp Contactsare on the next

page.

CRIMP TERMINATED

Page 8: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

72

1HBE 6 TERMINAL BLOCK ADAPTER INSERTS

View from Cable Side

Terminal Block: Right GroundTerminal Block: Left Ground

Plug70.300070.3010

Receptacle70.301170.3001

TOOLSWIRE GAUGE: 0.5 - 4.0 MM2

Locator11.1472

Crimp Dies11.1471

Crimp Tool11.1470

Removal Tool:11.1825

CONTACTS FOR HBE CRIMP TERMINATED INSERTSHBE MACHINED CONTACTS: DIAMETER 2.5MM

mm20.5

.75 - 1.01.52.54.0

AWG2018161412

StrippingLength (mm)

Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3

Pin11.190011.190111.190211.190311.1904

Socket11.195011.195111.195211.195311.1954

Pin11.192011.192111.1922

--

Socket11.197011.197111.1972

--

Silver GoldBags of 100

All dimensions are in mm.

One terminal block insert mates with one screw terminated insert.

These terminalblock inserts onlyfit in HBE 6 panel

mount bases

Page 9: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

73

1

Top Entry

Side Entry

PG13.516

13.516

NPT1/2”1/2”1/2”1/2”

Metric20252025

PGPart #

10.011010.021010.012010.0220

NPTPart #

10.0110NP10.0210NP10.0120NP10.0220NP

MetricPart #

19.011019.021019.012019.0220

PGPart #

70.021670.021070.023670.0230

NPTPart #

70.0216NP70.0210NP70.0236NP70.0230NP

MetricPart #

79.021679.021079.023679.0230

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.020270.020470.022270.0224

NPTPart #

70.0202NP70.0204NP70.0222NP70.0224NP

MetricPart #

79.020279.020479.022279.0224

PGPart #

70.021270.021470.023270.0234

NPTPart #

70.0212NP70.0214NP70.0232NP70.0234NP

MetricPart #

79.021279.021479.023279.0234

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

HBE 6 HIGH PROFILE HOODS WITH SINGLE LEVER BOLTS

StrainRelief

PG M

StrainRelief

PG NPT

HBE 6 HOODS WITH SINGLE LEVER BOLTS

TOP ENTRY SIDE ENTRY

Metric hoods do not come with a neck.

Metric hoods do not come with a neck.

TOP ENTRY SIDE ENTRY

M

All dimensions are in mm.

All dimensions are in mm.

NPT

Page 10: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

74

1

EMC Shielding is retrofittable.

HBE 6 PANEL MOUNT BASES WITH SINGLE LEVER

HBE 6 SURFACE MOUNT BASES WITH SINGLE LEVER

Panel Mount without Dust CoverPanel Mount with Dust Cover

Standard Grey Coating10.003010.0040

Black Coating (NEMA 4X)70.002570.0045

Description

2 Entries

1 Entry

2 Entries withdust cover1 Entry withdust cover

PG16

16

16

16

NPT1/2”

1/2”

1/2”

1/2”

Metric2025202520252025

PGPart #

10.0060

10.0050

10.0090

10.0070

NPTPart #

10.0060NP

10.0050NP

10.0090NP

10.0070NP

MetricPart #

19.006079.006619.005079.005619.009079.016619.007079.0156

PGPart #

70.0080

70.0070

70.0180

70.0170

NPTPart #

70.0080NP

70.0070NP

70.0180NP

70.0170NP

MetricPart #

79.008079.008679.007079.007679.018079.018679.017079.0176

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# of Entries

StrainRelief

PG NPT M

Panel Mount BaseSurface Mount & Cable Coupler Hood

PG/NPT70.350070.3520

Metric79.350079.3520

EMC PROTECTION

All dimensions are in mm.

All dimensions are in mm.

Page 11: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

75

1

STANDARD PROFILE HIGH PROFILE

2 Entries

1 Entry

2 Entries withdust cover1 Entry withdust cover

PG2129212921292129

NPT3/4”1”

3/4”1”

3/4”1”

3/4”1”

Metric2532253225322532

PGPart #

70.006270.006470.005270.005470.016270.016470.015270.0154

NPTPart #

70.0062NP70.0064NP70.0052NP70.0054NP70.0162NP70.0164NP70.0152NP70.0154NP

MetricPart #

79.006279.006479.005279.005479.016279.016479.015279.0154

PGPart #

70.008270.008470.007270.007470.018270.018470.017270.0174

NPTPart #

70.0082NP70.0084NP70.0072NP70.0074NP70.0182NP70.0184NP70.0172NP70.0174NP

MetricPart #

79.008279.008479.007279.007479.018279.018479.017279.0174

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# of Entries

StrainRelief

PG NPT M

StandardProfileHigh

Profile

PG13.5162129

NPT1/2”1/2”3/4”1”

Metric20252532

PGPart #

10.014010.024070.010270.0104

NPTPart #

10.0140NP10.0240NP70.0102NP70.0104NP

MetricPart #

19.014019.024079.010279.0104

PGPart #

-70.011070.011270.0114

NPTPart #

-70.0110NP70.0112NP70.0114NP

MetricPart #

79.011079.011679.011279.0114

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Profile

StrainRelief

HBE 6 CABLE COUPLER HOOD WITH SINGLE LEVER

HBE 6 HIGH PROFILE SURFACE MOUNT BASES WITH SINGLE LEVER

Metric hoods do not come with a neck.

MPG NPT

All dimensions are in mm.

Page 12: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

76

1HBE 10 SCREW & CRIMP TERMINATED INSERTS

SCREW TERMINATED View from Cable Side

Panel Cut-Out

Panel Cut-Out

Same View fromCable Side as

Screw & CrimpTermination

Contacts Sold Separately

Screw Terminated with wire protectionScrew Terminated without wire protectionCrimp Terminated: Machined

Plug10.192010.192110.1820

Receptacle10.193010.193110.1830

Screwless Cage ClampPlug

10.4001Receptacle

10.4011

HBE 10 SCREWLESS SPRING CAGE CLAMP INSERTS

All dimensions are in mm.

All dimensions are in mm.

These inserts fit inthe HBE 10 SeriesHousings which

are on the following pages.

Crimp Contactsare on the next

page.

These inserts fit inthe HBE 10 SeriesHousings which

are on the follow-ing pages.

CRIMP TERMINATED

Page 13: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

77

1HBE 10 TERMINAL BLOCK ADAPTER INSERTS

TOOLSWIRE GAUGE: 0.5 - 4.0 MM2

View from Cable Side

Terminal Block: Right GroundTerminal Block: Left Ground

Plug70.302070.3030

Receptacle70.303170.3021

Locator11.1472

Crimp Dies11.1471

Crimp Tool11.1470

Removal Tool:11.1825

CONTACTS FOR HBE CRIMP TERMINATED INSERTSHBE MACHINED CONTACTS: DIAMETER 2.5MM

All dimensions are in mm.

These terminalblock inserts onlyfit in HBE 10 panel

mount bases.

mm20.5

0.75 - 1.01.52.54.0

AWG2018161412

StrippingLength (mm)

Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3

Pin11.190011.190111.190211.190311.1904

Socket11.195011.195111.195211.195311.1954

Pin11.192011.192111.1922

--

Socket11.197011.197111.1972

--

Silver GoldBags of 100

One terminal block insert mates with one screw terminated insert.

Page 14: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

78

1 TOP ENTRY SIDE ENTRY

Top Entry

Side Entry

PG16211621

NPT1/2”3/4”1/2”3/4”

Metric20252025

PGPart #

10.040910.040710.042910.0428

NPTPart #

10.0409NP10.0407NP10.0429NP10.0428NP

MetricPart #

19.040919.040719.042919.0428

PGPart #

70.049070.049670.059070.0596

NPTPart #

70.0490NP70.0496NP70.0590NP70.0596NP

MetricPart #

79.049079.049679.059079.0596

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.044270.044470.054270.0544

NPTPart #

70.0442NP70.0444NP70.0542NP70.0544NP

MetricPart #

79.044279.044479.054279.0544

PGPart #

70.049270.049470.059270.0594

NPTPart #

70.0492NP70.0494NP70.0592NP70.0594NP

MetricPart #

79.049279.049479.059279.0594

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Metric hoods do not come with a neck.

HBE 10 HIGH PROFILE HOODS WITH SINGLE LEVER BOLTS

TOP ENTRY SIDE ENTRY

Metric hoods do not come with a neck.

All dimensions are in mm.

All dimensions are in mm.

HBE 10 HOODS WITH SINGLE LEVER BOLTS

Page 15: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

79

1HBE 10 PANEL MOUNT BASES WITH SINGLE LEVER

HBE 10 SURFACE MOUNT BASES WITH SINGLE LEVER

Panel Mount without Dust CoverPanel Mount with Dust Cover

Standard Grey Coating10.032910.0339

Black Coating (NEMA 4X)70.032770.0337

Description

2 Entries

1 Entry

2 Entries withdust cover1 Entry withdust cover

PG16

162116

16

NPT1/2”

1/2”3/4”1/2”

1/2”

Metric2025202520252025

PGPart #

10.0359-

10.034910.034710.0389

-10.0369

-

NPTPart #

10.0359NP-

10.0349NP10.0347NP10.0389NP

-10.0369NP

-

MetricPart #

19.035979.061619.034919.034719.038979.065619.036979.0646

PGPart #

70.0630-

70.0620-

70.0670-

70.0660-

NPTPart #

70.0630NP-

70.0620NP-

70.0670NP-

70.0660NP-

MetricPart #

79.063079.063679.062079.062679.067079.067679.066079.0666

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# of Entries

StrainRelief

PG NPT M

All dimensions are in mm.

All dimensions are in mm.

Page 16: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

80

1

HBE 10 CABLE COUPLER HOOD WITH SINGLE LEVER

2 Entries

1 Entry

2 Entries withdust cover1 Entry withdust cover

PG2129212921292129

NPT3/4”1”

3/4”1”

3/4”1”

3/4”1”

Metric2532253225322532

PGPart #

70.061270.061470.060270.060470.065270.065470.064270.0644

NPTPart #

70.0612NP70.0614NP70.0602NP70.0604NP70.0652NP70.0654NP70.0642NP70.0644NP

MetricPart #

79.061279.061479.060279.060479.065279.065479.064279.0644

PGPart #

70.063270.063470.062270.062470.067270.067470.066270.0664

NPTPart #

70.0632NP70.0634NP70.0622NP70.0624NP70.0672NP70.0674NP70.0662NP70.0664NP

MetricPart #

79.063279.063479.062279.062479.067279.067479.066279.0664

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# of Entries

StrainRelief

PG NPT M

StandardProfileHigh

Profile

PG16212129

NPT1/2”3/4”3/4”1”

Metric20252532

PGPart #

10.046970.042270.042470.0426

NPTPart #

10.0469NP70.0422NP70.0424NP70.0426NP

MetricPart #

19.046979.042279.042479.0426

PGPart #

70.043070.043270.043470.0436

NPTPart #

70.0430NP70.0432NP70.0434NP70.0436NP

MetricPart #

79.043079.043279.043479.0436

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Profile

StrainRelief

HBE 10 HIGH PROFILE SURFACE MOUNT BASES WITH SINGLE LEVER

Metric hoods do not come with a neck.

PG NPT M

All dimensions are in mm.

All dimensions are in mm.

STANDARD PROFILE HIGH PROFILE

Page 17: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

81

1HBE 10 HOODS WITH DOUBLE LEVER BOLTS

TOP ENTRY SIDE ENTRY

Top Entry

Side Entry

PG16211621

NPT1/2”3/4”1/2”3/4”

Metric20252025

PGPart #

10.040010.040110.042010.0421

NPTPart #

10.0400NP10.0401NP10.0420NP10.0421NP

MetricPart #

19.040019.040119.042019.0421

PGPart #

70.051070.051270.053070.0532

NPTPart #

70.0510NP70.0512NP70.0530NP70.0532NP

MetricPart #

79.051079.051279.053079.0532

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.050470.050670.052470.0526

NPTPart #

70.0504NP70.0506NP70.0524NP70.0526NP

MetricPart #

79.050479.050679.052479.0526

PGPart #

70.051470.051670.053470.0536

NPTPart #

70.0514NP70.0516NP70.0534NP70.0536NP

MetricPart #

79.051479.051679.053479.0536

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Metric hoods do not come with a neck.

Metric hoods do not come with a neck.

All dimensions are in mm.

All dimensions are in mm.

HBE 10 HIGH PROFILE HOODS WITH DOUBLE LEVER BOLTS

TOP ENTRY SIDE ENTRY

Page 18: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

82

1HBE 10 PANEL MOUNT BASES WITH DOUBLE LEVERS

HBE 10 SURFACE MOUNT BASES WITH DOUBLE LEVERS

Panel Mount without Dust CoverStandard Grey Coating

10.0320Black Coating (NEMA 4X)

70.0325

Description

2 Entries

1 Entry

PG16

16

NPT1/2”

1/2”

Metric20252025

PGPart #

10.0350-

10.0340-

NPTPart #

10.0350NP-

10.0340NP-

MetricPart #

19.035019.035119.034019.0341

PGPart #

70.0380-

70.0370-

NPTPart #

70.0380NP-

70.0370NP-

MetricPart #

79.038079.038679.037079.0376

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# of Entries

StrainRelief

PG NPT M

All dimensions are in mm.

All dimensions are in mm.

EMC Shielding is retrofittable.

Panel Mount BaseSurface Mount & Cable Coupler Hood

PG/NPT70.350170.3521

Metric79.350179.3521

EMC PROTECTION

Page 19: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

83

1

STANDARD PROFILE HIGH PROFILE

HBE 10 CABLE COUPLER HOOD WITH DOUBLE LEVER

StandardProfileHigh

Profile

PG16212129

NPT1/2”3/4”3/4”1”

Metric20252532

PGPart #

10.046070.040270.040470.0406

NPTPart #

10.0460NP70.0402NP70.0404NP70.0406NP

MetricPart #

19.046079.040279.040479.0406

PGPart #

70.041070.041270.041470.0416

NPTPart #

70.0410NP70.0412NP70.0414NP70.0416NP

MetricPart #

79.041079.041279.041479.0416

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Profile

StrainRelief

PG NPT

2 Entries

1 Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.036270.036470.035270.0354

NPTPart #

70.0362NP70.0364NP70.0352NP70.0354NP

MetricPart #

79.036279.036479.035279.0354

PGPart #

70.038270.038470.037270.0374

NPTPart #

70.0382NP70.0384NP70.0372NP70.0374NP

MetricPart #

79.038279.038479.037279.0374

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# of Entries

StrainRelief

PG NPT M

HBE 10 HIGH PROFILE SURFACE MOUNT BASESWITH DOUBLE LEVERS

Metric hoods do not come with a neck.

M

All dimensions are in mm.

All dimensionsare in mm.

Page 20: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

84

1HBE 10 HOODS WITH DOUBLE LEVERS

Top Entry

Side Entry

PG16

16

NPT1/2”

1/2”

Metric20252025

PGPart #

10.0410-

10.0450-

NPTPart #

10.0410NP-

10.0450NP-

MetricPart #

19.041079.055719.045079.0577

PGPart #

70.0560-

70.0580-

NPTPart #

70.0560NP-

70.0580NP-

MetricPart #

79.056079.056679.058079.0586

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

HBE 10 HIGH PROFILE HOODS WITH DOUBLE LEVERS

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.055270.055470.057270.0574

NPTPart #

70.0552NP70.0554NP70.0572NP70.0574NP

MetricPart #

79.055279.055479.057279.0574

PGPart #

70.056270.056470.058270.0584

NPTPart #

70.0562NP70.0564NP70.0582NP70.0584NP

MetricPart #

79.056279.056479.058279.0584

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Metric hoods do not come with a neck.

Metric hoods do not come with a neck.

TOP ENTRY SIDE ENTRY

TOP ENTRY SIDE ENTRY

All dimensions are in mm.

All dimensions are in mm.

Page 21: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

85

1HBE 10 PANEL MOUNT BASES WITH DOUBLE LEVER BOLTS

HBE 10 SURFACE MOUNT BASES WITH DOUBLE BOLTS

Panel Mount with Dust CoverStandard Grey Coating

10.0330Black Coating (NEMA 4X)

70.0335

Description

2 Entries

1 Entry

PG16

16

NPT1/2”

1/2”

Metric20252025

PGPart #

10.0380-

10.0360-

NPTPart #

10.0380NP-

10.0360NP-

MetricPart #

19.038079.046619.036019.0361

PGPart #

70.0480-

70.0470-

NPTPart #

70.0480NP-

70.0470NP-

MetricPart #

79.048079.048679.047079.0476

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# of Entries

StrainRelief

PG NPT M

STANDARD PROFILE HIGH PROFILE

2 Entries

1 Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.046270.046470.045270.0454

NPTPart #

70.0462NP70.0464NP70.0452NP70.0454NP

MetricPart #

79.046279.046479.045279.0454

PGPart #

70.048270.048470.047270.0474

NPTPart #

70.0482NP70.0484NP70.0472NP70.0474NP

MetricPart #

79.048279.048479.047279.0474

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# of Entries

StrainRelief

PG NPT M

All dimensions are in mm.

All dimensions are in mm.

HIGH PROFILE

STANDARD PROFILE

Page 22: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

86

HBE 16 SCREW & CRIMP TERMINATED INSERTSCRIMP TERMINATEDView from Cable Side

Panel Cut-Out

Panel Cut-Out

Same View fromCable Side as

Screw & CrimpTermination

Contacts Sold Separately

Screw Terminated with wire protectionScrew Terminated without wire protectionCrimp Terminated: Machined

Plug10.194010.194110.1840

Receptacle10.195010.195110.1850

HBE 16 SCREWLESS SPRING CAGE CLAMP INSERTS

Screwless Cage ClampPlug

10.4002Receptacle

10.4012

All dimensions are in mm.

All dimensions are in mm.

These inserts fit inthe HBE 16 SeriesHousings which

are on thefollowing pages.

These inserts fit inthe HBE 16 SeriesHousings which

are on the follow-ing pages.

CrimpContacts areon the next

page.

SCREW TERMINATED1

Page 23: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

87

Terminal Block: Right GroundTerminal Block: Left Ground

Plug70.304070.3050

Receptacle70.305170.3041

View from Cable Side

HBE 16 TERMINAL BLOCK ADAPTER INSERTS

TOOLSWIRE GAUGE: 0.5 - 4.0 MM2

Locator11.1472

Crimp Dies11.1471

Crimp Tool11.1470

Removal Tool:11.1825

HBE MACHINED CONTACTS: DIAMETER 2.5MM

mm20.5

.75 - 1.01.52.54.0

AWG2018161412

StrippingLength (mm)

Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3

Pin11.190011.190111.190211.190311.1904

Socket11.195011.195111.195211.195311.1954

Pin11.192011.192111.1922

--

Socket11.197011.197111.1972

--

Silver GoldBags of 100

CONTACTS FOR HBE CRIMP TERMINATED INSERTS

All dimensions are in mm.These terminal

block inserts onlyfit in HBE 16 panel

mount bases.

One terminal block insert mates with one screw terminated insert.

1

Page 24: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

88

1HBE 16 HOODS WITH SINGLE LEVER BOLTS

TOP ENTRY SIDE ENTRY

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

10.080910.090910.082910.0929

NPTPart #

10.0809NP10.0909NP10.0829NP10.0929NP

MetricPart #

19.080919.090919.082919.0929

PGPart #

70.0990-

70.1090-

NPTPart #

70.0990NP-

70.1090NP-

MetricPart #

79.0990-

79.1090-

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.094270.094470.104270.1044

NPTPart #

70.0942NP70.0944NP70.1042NP70.1044NP

MetricPart #

79.094279.094479.104279.1044

PGPart #

70.099270.099470.109270.1094

NPTPart #

70.0992NP70.0994NP70.1092NP70.1094NP

MetricPart #

79.099279.099479.109279.1094

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Metric hoods do not come with a neck.

Metric hoods do not come with a neck.

HBE 16 HIGH PROFILE HOODS WITH SINGLE LEVER BOLTSTOP ENTRY SIDE ENTRY

All dimensions are in mm.

All dimensions are in mm.

Page 25: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

89

1HBE 16 PANEL MOUNT BASES WITH SINGLE LEVER

HBE 16 SURFACE MOUNT BASES WITH SINGLE LEVER

Panel mount without dust coverPanel mount with dust cover

Standard Grey Coating10.072910.0739

Black Coating (NEMA 4X)70.082770.0837

Description

2 Entries1 Entry2 Entries withdust cover1 Entry withdust cover

PG212121

21

NPT3/4”3/4”3/4”

3/4”

Metric252525

25

PGPart #

10.075910.074910.0789

10.0769

NPTPart #

10.0759NP10.0749NP10.0789NP

10.0769NP

MetricPart #

19.075919.074919.0789

19.0769

PGPart #

70.113070.112070.1170

70.1160

NPTPart #

70.1130NP70.1120NP70.1170NP

70.1160NP

MetricPart #

79.113079.112079.1170

79.1160

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# of Entries

StrainRelief

PG NPT M

All dimensions are in mm.

All dimensions are in mm.

Page 26: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

90

1

STANDARD PROFILE HIGH PROFILE

2 Entries

1 Entry

2 Entries withdust cover1 Entry withdust cover

PG2129212921292129

NPT3/4”1”

3/4”1”

3/4”1”

3/4”1”

Metric2532253225322532

PGPart #

70.111270.111470.110270.110470.115270.115470.114270.1144

NPTPart #

70.1112NP70.1114NP70.1102NP70.1104NP70.1152NP70.1154NP70.1142NP70.1144NP

MetricPart #

79.111279.111479.110279.110479.115279.115479.114279.1144

PGPart #

70.113270.113470.112270.112470.117270.117470.116270.1164

NPTPart #

70.1132NP70.1134NP70.1122NP70.1124NP70.1172NP70.1174NP70.1162NP70.1164NP

MetricPart #

79.113279.113479.112279.112479.117279.117479.116279.1164

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# of Entries

StrainRelief

PG NPT M

Standard

High

MetricPart #

19.086919.096979.092279.0924

PGPart #

70.093070.096970.093270.0934

NPTPart #

70.0930NP70.0969NP70.0932NP70.0934NP

MetricPart #

79.093079.096979.093279.0934

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Profile

StrainRelief

HBE 16 CABLE COUPLER HOODS WITH SINGLE LEVER

HBE 16 HIGH PROFILE SURFACE MOUNT BASES WITH SINGLE LEVER

Metric hoods do not come with a neck.

PG NPT M

All dimensions are in mm.

All dimensions are in mm.

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

10.086910.096970.092270.0924

NPTPart #

10.0869NP10.0969NP70.0922NP70.0924NP

Page 27: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

91

1TOP ENTRY SIDE ENTRY

HBE 16 HOODS WITH DOUBLE LEVER BOLTS

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

10.080010.090010.082010.0920

NPTPart #

10.0800NP10.0900NP10.0820NP10.0920NP

MetricPart #

19.080019.090019.082019.0920

PGPart #

70.1010-

70.1030-

NPTPart #

70.1010NP-

70.1030NP-

MetricPart #

79.1010-

79.1030-

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.100270.100470.102270.1024

NPTPart #

70.1002NP70.1004NP70.1022NP70.1024NP

MetricPart #

79.100279.100479.102279.1024

PGPart #

70.101270.101470.103270.1034

NPTPart #

70.1012NP70.1014NP70.1032NP70.1034NP

MetricPart #

79.101279.101479.103279.1034

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Metric hoods do not come with a neck.

HBE 16 HIGH PROFILE HOODS WITH DOUBLE LEVER BOLTS

Metric hoods do not come with a neck.

TOP ENTRY SIDE ENTRY

All dimensions are in mm.

All dimensions are in mm.

Page 28: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

92

1HBE 16 PANEL MOUNT BASES WITH DOUBLE LEVERS

HBE 16 SURFACE MOUNT BASES WITH DOUBLE LEVERS

Panel Mount without Dust CoverStandard Grey Coating

10.0720Black Coating (NEMA 4X)

70.0825

Description

2 Entries1 Entry

PG2121

NPT3/4”3/4”

Metric2525

PGPart #

10.075010.0740

NPTPart #

10.0750NP10.0740NP

MetricPart #

19.075019.0740

PGPart #

70.088070.0870

NPTPart #

70.0880NP70.0870NP

MetricPart #

79.088079.0870

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Mounting Type

StrainRelief

PG NPT M

EMC Shielding is retrofittable.

Panel Mount BaseSurface Mount & Cable Coupler Hood

PG/NPT70.350270.3522

Metric79.350279.3522

EMC PROTECTION

All dimensions are in mm.

All dimensions are in mm.

Page 29: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

93

1

2 Entries

1 Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.086270.086470.085270.0854

NPTPart #

70.0862NP70.0864NP70.0852NP70.0854NP

MetricPart #

79.086279.086479.085279.0854

PGPart #

70.088270.088470.087270.0874

NPTPart #

70.0882NP70.0884NP70.0872NP70.0874NP

MetricPart #

79.088279.088479.087279.0874

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# of Entries

StrainRelief

PG NPT M

HBE 16 HIGH PROFILE BASES WITH DOUBLE LEVERS

HIGH PROFILESTANDARD PROFILE

HBE 16 CABLE COUPLER HOODS WITH DOUBLE LEVERS

Standard

High

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

10.086010.096070.090270.0904

NPTPart #

10.0860NP10.0960NP70.0902NP70.0904NP

MetricPart #

19.086019.096079.090279.0904

PGPart #

70.0910-

70.091270.0914

NPTPart #

70.0910NP-

70.0912NP70.0914NP

MetricPart #

79.0910-

79.091279.0914

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Profile

StrainRelief

Metric hoods do not come with a neck.

PG NPT M

All dimensions are in mm.

All dimensions are in mm.

Page 30: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

94

HBE 16 HOODS WITH DOUBLE LEVERS

TOP ENTRY SIDE ENTRY

TOP ENTRY SIDE ENTRY

HBE 16 HIGH PROFILE HOODS WITH DOUBLE LEVERS

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.105270.105470.107270.1074

NPTPart #

70.1052NP70.1054NP70.1072NP70.1074NP

MetricPart #

79.105279.105479.107279.1074

PGPart #

70.106270.106470.108270.1084

NPTPart #

70.1062NP70.1064NP70.1082NP70.1084NP

MetricPart #

79.106279.106479.108279.1084

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Metric hoods do not come with a neck.

Metric hoods do not come with a neck.

All dimensions are in mm.

All dimensions are in mm.

Top Entry

Side Entry

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

10.081010.091010.083010.0930

NPTPart #

10.0810NP10.0910NP10.0830NP10.0930NP

MetricPart #

19.081019.091019.083019.0930

PGPart #

70.1060-

70.1080-

NPTPart #

70.1060NP-

70.1080NP-

MetricPart #

79.1060-

79.1080-

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT MPG21292129

1

Page 31: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

95

HBE 16 PANEL MOUNT BASES WITH DOUBLE LEVER BOLTS

Panel Mount with Dust CoverPanel Mount without Dust Cover

Standard Grey Coating10.073010.0731

Black Coating (NEMA 4X)70.0835

-

Description

2 Entries1 EntryHigh Profilewith 2 EntriesHigh Profilewith 1 Entry

PG212121292129

NPT3/4”3/4”3/4”1”

3/4”1”

Metric252525322532

PGPart #

70.096010.076070.096270.096470.095270.0954

NPTPart #

70.0960NP10.0760NP70.0962NP70.0964NP70.0952NP70.0954NP

MetricPart #

79.096019.097079.096279.096479.095279.0954

PGPart #

70.098070.097070.098270.098470.097270.0974

NPTPart #

70.0980NP70.0970NP70.0982NP70.0984NP70.0972NP70.0974NP

MetricPart #

79.098079.097079.098279.098479.097279.0974

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# of Entries

StrainRelief

PG NPT M

HBE 16 SURFACE MOUNT BASES WITH DOUBLE LEVER BOLTS

Panel Mount BaseSurface Mount & Cable Coupler Hood

PG/NPT70.350270.3522

Metric79.350279.3522

EMC PROTECTION

EMC Shielding is retrofittable.

All dimensions are in mm.

All dimensions are in mm.

HIGH PROFILESTANDARD PROFILE

1

Page 32: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

96

1HBE 24 SCREW & CRIMP TERMINATED INSERTS

SCREW TERMINATED CRIMP TERMINATEDView from Cable Side

Panel Cut-Out

Panel Cut-Out

Same View fromCable Side as

Screw & CrimpTermination

Contacts Sold Separately

Screw Terminated with wire protectionScrew Terminated without wire protectionCrimp Terminated: Machined

Plug10.196010.196110.1860

Receptacle10.197010.197110.1870

HBE 24 SCREWLESS SPRING CAGE CLAMP INSERTS

Screwless Cage ClampPlug

10.4003Receptacle

10.4013

All dimensions are in mm.

All dimensions are in mm.

These inserts fit inthe HBE 24 Series

Housings which areon the following

pages.

These inserts fit inthe HBE 24 Series

Housings which areon the following

pages.

CrimpContacts areon the next

page.

Page 33: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

97

1

View from Cable Side

Terminal Block: Right GroundTerminal Block: Left Ground

Plug70.306070.3070

Receptacle70.307170.3061

HBE 24 TERMINAL BLOCK ADAPTER INSERTS

TOOLSWIRE GAUGE: 0.5 - 4.0 MM2

Locator11.1472

Crimp Dies11.1471

Crimp Tool11.1470

Removal Tool:11.1825

CONTACTS FOR HBE CRIMP TERMINATED INSERTSHBE MACHINED CONTACTS: DIAMETER 2.5MM

mm20.5

.75 - 1.01.52.54.0

AWG2018161412

StrippingLength (mm)

Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3

Pin11.190011.190111.190211.190311.1904

Socket11.195011.195111.195211.195311.1954

Pin11.192011.192111.1922

--

Socket11.197011.197111.1972

--

Silver GoldBags of 100

All dimensions are in mm.

These terminalblock inserts only

fit in HBE 24panel mount

bases. One terminal block insert mates with one screw terminated insert.

Page 34: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

98

1HBE 24 HOODS WITH SINGLE LEVER BOLTS

TOP ENTRY SIDE ENTRY

Metric hoods do not come with a neck.

Metric hoods do not come with a neck.

HBE 24 HIGH PROFILE HOODS WITH SINGLE LEVER BOLTS

SIDE ENTRYTOP ENTRY

All dimensions are in mm.

All dimensions are in mm.

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

10.121910.111910.113910.1239

NPTPart #

10.1219NP10.1119NP10.1139NP10.1239NP

MetricPart #

19.121919.111919.113919.1239

PGPart #

70.149070.149270.159070.1592

NPTPart #

70.1490NP70.1492NP70.1590NP70.1592NP

MetricPart #

79.149079.149279.159079.1592

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.144470.144670.154470.1546

NPTPart #

70.1444NP70.1446NP70.1544NP70.1546NP

MetricPart #

79.144479.144679.154479.1546

PGPart #

70.149470.149670.159470.1596

NPTPart #

70.1494NP70.1496NP70.1594NP70.1596NP

MetricPart #

79.149479.149679.159479.1596

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Page 35: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

99

1HBE 24 PANEL MOUNT BASES WITH SINGLE LEVER

HBE 24 SURFACE MOUNT BASES WITH SINGLE LEVER

EMC PROTECTION

EMC Shielding is retrofittable.

All dimensions are in mm.

All dimensions are in mm.

Panel Mount without dust coverPanel Mount with dust cover

Standard Grey Coating10.102910.1039

Black Coating (NEMA 4X)70.132770.1337

Description

2 Entries1 Entry2 with cover1 with cover

PG21212121

NPT3/4”3/4”3/4”3/4”

Metric25252525

PGPart #

10.105910.104910.109910.1079

NPTPart #

10.1059NP10.1049NP10.1099NP10.1079NP

MetricPart #

19.105919.104919.109919.1079

PGPart #

70.163070.162070.167070.1660

NPTPart #

70.1630NP70.1620NP70.1670NP70.1660NP

MetricPart #

79.163079.162079.167079.1660

Standard Grey CoatingSize of Entry# ofEntries

StrainRelief

PG NPT M

Panel Mount BaseSurface Mount & Cable Coupler Hood

PG/NPT70.350370.3523

Metric79.350379.3523

Black Coating (NEMA 4X)

Page 36: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

100

1

Metric hoods do not come with a neck.

HIGH PROFILESTANDARD PROFILE

HBE 24 CABLE COUPLER HOODS WITH SINGLE LEVER

All dimensions are in mm.

All dimensions are in mm.

HBE 24 HIGH PROFILE SURFACE MOUNT BASES WITH SINGLE LEVER

2 Entries

1 Entry

2 Entries withdust cover1 Entry withdust cover

PG2129212921292129

NPT3/4”1”

3/4”1”

3/4”1”

3/4”1”

Metric2532253225322532

PGPart #

70.161270.161470.160270.160470.165270.165470.164270.1644

NPTPart #

70.1612NP70.1614NP70.1602NP70.1604NP70.1652NP70.1654NP70.1642NP70.1644NP

MetricPart #

79.161279.161479.160279.160479.165279.165479.164279.1644

PGPart #

70.163270.163470.162270.162470.167270.167470.166270.1664

NPTPart #

70.1632NP70.1634NP70.1622NP70.1624NP70.1672NP70.1674NP70.1662NP70.1664NP

MetricPart #

79.163279.163479.162279.162479.167279.167479.166279.1664

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# ofEntries

StrainRelief

PG NPT M

Standard

High Profile

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

10.127910.117970.142470.1426

NPTPart #

10.1279NP10.1179NP70.1424NP70.1426NP

MetricPart #

19.127919.117979.142479.1426

PGPart #

70.143070.143270.143470.1436

NPTPart #

70.1430NP70.1432NP70.1434NP70.1436NP

MetricPart #

79.143079.143279.143479.1436

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Profile

StrainRelief

PG NPT M

Page 37: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

101

1TOP ENTRY SIDE ENTRY

Metric hoods do not come with a neck.

Metric hoods do not come with a neck.

All dimensions are in mm.

All dimensions are in mm.

HBE 24 HOODS WITH DOUBLE LEVER BOLTS

HBE 24 HIGH PROFILE HOODS WITH DOUBLE LEVER BOLTS

TOP ENTRY SIDE ENTRY

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

10.121010.111010.113010.1230

NPTPart #

10.1210NP10.1110NP10.1130NP10.1230NP

MetricPart #

19.121019.111019.113019.1230

PGPart #

70.151070.151270.153070.1532

NPTPart #

70.1510NP70.1512NP70.1530NP70.1532NP

MetricPart #

79.151079.151279.153079.1532

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.150470.150670.152470.1526

NPTPart #

70.1504NP70.1506NP70.1524NP70.1526NP

MetricPart #

79.150479.150679.152479.1526

PGPart #

70.151470.151670.153470.1536

NPTPart #

70.1514NP70.1516NP70.1534NP70.1536NP

MetricPart #

79.151479.151679.153479.1536

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Page 38: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

102

1HBE 24 PANEL MOUNT BASES WITH DOUBLE LEVERS

HBE 24 SURFACE MOUNT BASES WITH DOUBLE LEVERS

EMC PROTECTION

EMC Shielding is retrofittable.

All dimensions are in mm.

All dimensions are in mm.

Panel Mount without Dust CoverStandard Grey Coating

10.1020Black Coating (NEMA 4X)

70.1325

Description

2 Entries1 Entry

PG2121

NPT3/4”3/4”

Metric2525

PGPart #

10.105010.1040

NPTPart #

10.1050NP10.1040NP

MetricPart #

19.105019.1040

PGPart #

70.138070.1370

NPTPart #

70.1380NP70.1370NP

MetricPart #

79.138079.1370

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# ofEntries

StrainRelief

PG NPT M

Panel Mount BaseSurface Mount & Cable Coupler Hood

PG/NPT70.350370.3523

Metric79.350379.3523

Page 39: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

103

1

HBE 24 CABLE COUPLER HOOD WITH DOUBLE LEVERSSTANDARD PROFILE HIGH PROFILE

HBE 24 HIGH PROFILE SURFACE MOUNT BASES WITH DOUBLE LEVERS

Metric hoods do not come with a neck.

All dimensions are in mm.

All dimensions are in mm.

Standard

High Profile

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

10.127010.117070.140470.1406

NPTPart #

10.1270NP10.1170NP70.1404NP70.1406NP

MetricPart #

19.127019.117079.140479.1406

PGPart #

70.141070.141270.141470.1416

NPTPart #

70.1410NP70.1412NP70.1414NP70.1416NP

MetricPart #

79.141079.141279.141479.1416

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Profile

StrainRelief

PG NPT M

2 Entries

1 Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.136270.136470.135270.1354

NPTPart #

70.1362NP70.1364NP70.1352NP70.1354NP

MetricPart #

79.136279.136479.135279.1354

PGPart #

70.138270.138470.137270.1374

NPTPart #

70.1382NP70.1384NP70.1372NP70.1374NP

MetricPart #

79.138279.138479.137279.1374

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Page 40: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

104

1HBE 24 HOODS WITH DOUBLE LEVERS

TOP ENTRY SIDE ENTRY

HBE 24 HIGH PROFILE HOODS WITH DOUBLE LEVERS

Metric hoods do not come with a neck.

Metric hoods do not come with a neck.

TOP ENTRY SIDE ENTRY

All dimensions are in mm.

All dimensions are in mm.

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

10.122010.112010.114010.1240

NPTPart #

10.1220NP10.1120NP10.1140NP10.1240NP

MetricPart #

19.122019.112019.114019.1240

PGPart #

70.156070.156270.158070.1582

NPTPart #

70.1560NP70.1562NP70.1580NP70.1582NP

MetricPart #

79.156079.156279.158079.1582

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Top Entry

Side Entry

PG21292129

NPT3/4”1”

3/4”1”

Metric25322532

PGPart #

70.155470.155670.157470.1576

NPTPart #

70.1554NP70.1556NP70.1574NP70.1576NP

MetricPart #

79.155479.155679.157479.1576

PGPart #

70.156470.156670.158470.1586

NPTPart #

70.1564NP70.1566NP70.1584NP70.1586NP

MetricPart #

79.156479.156679.158479.1586

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)Position ofCable Entry

StrainRelief

PG NPT M

Page 41: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

105

1HBE 24 PANEL MOUNT BASES WITH DOUBLE LEVER BOLTS

HBE 24 SURFACE MOUNT BASES WITH DOUBLE LEVER BOLTS

STANDARD PROFILE HIGH PROFILE

EMC PROTECTION

EMC Shielding is retrofittable.

All dimensions are in mm.

All dimensions are in mm.

Panel Mount with Dust coverPanel Mount without cover

Standard Grey Coating10.103010.1031

Black Coating (NEMA 4X)70.1335

-

Description

2 Entries1 EntryHigh Profilewith 2 Entries High Profilewith 1 Entry

PG212121292129

NPT3/4”3/4”3/4”1”

3/4”1”

Metric252525322532

PGPart #

10.109010.107070.146270.146470.145270.1454

NPTPart #

10.1090NP10.1070NP70.1462NP70.1464NP70.1452NP70.1454NP

MetricPart #

19.109019.107079.146279.146479.145279.1454

PGPart #

70.148070.147070.148270.148470.147270.1474

NPTPart #

70.1480NP70.1470NP70.1482NP70.1484NP70.1472NP70.1474NP

MetricPart #

79.148079.147079.148279.148479.147279.1474

Standard Grey CoatingSize of Entry Black Coating (NEMA 4X)# ofEntries

StrainRelief

PG NPT

Panel Mount BaseSurface Mount & Cable Coupler Hood

PG/NPT70.350370.3523

Metric79.350379.3523

M

Page 42: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

106

1

wwwwww.contactelectronics.com.contactelectronics.com800-221-1451800-221-1451

SCREW TERMINATED CRIMP TERMINATEDView from Cable Side

Panel Cut-Out

Panel Cut-Out

HBE 32 SCREW & CRIMP TERMINATED INSERTS

Screw Terminated with wire protection (#1-16)Screw Terminated with wire protection (#17-32)Screw Terminated without wire protection (#1-16)Screw Terminated without wire protection (#17-32)Crimp Terminated: Machined (#1-16)Crimp Terminated: Machined (#17-32)

Plug10.194010.202010.194110.202110.184010.1842

Receptacle10.195010.203010.195110.203110.185010.1852

Screwless Cage Clamp (#1-16)Screwless Cage Clamp (#17-32)

Plug10.400210.4004

Receptacle10.401210.4014

Same View fromCable Side as

Screw & CrimpTermination

Contacts Sold Separately

All dimensions are in mm.

All dimensions are in mm.

These inserts fitin the HBE 32

Series Housingswhich are on thefollowing pages.

CrimpContacts areon the next

page.

These inserts fitin the HBE 32

Series Housingswhich are on thefollowing pages.

HBE 32 SCREWLESS SPRING CAGE CLAMP INSERTS

Page 43: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

wwwwww.contactelectronics.com.contactelectronics.com800-221-1451800-221-1451

107

1HBE 32 TERMINAL BLOCK ADAPTER INSERTS

TOOLSWIRE GAUGE: 0.5 - 4.0 MM2

Locator11.1472

Crimp Dies11.1471

Crimp Tool11.1470

Removal Tool:11.1825

CONTACTS FOR HBE CRIMP TERMINATED INSERTSHBE MACHINED CONTACTS: DIAMETER 2.5MM

mm20.5

.75 - 1.01.52.54.0

AWG2018161412

StrippingLength (mm)

Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3

Pin11.190011.190111.190211.190311.1904

Socket11.195011.195111.195211.195311.1954

Pin11.192011.192111.1922

--

Socket11.197011.197111.1972

--

Silver GoldBags of 100

View from Cable SideThese terminalblock inserts

only fit in HBE32 panel mount

bases.

Terminal Block: Right Ground (#1-16)Terminal Block: Left Ground (#17-32)

Plug70.304070.3042

Receptacle70.304170.3043

All dimensions are in mm.

Two terminal block inserts mate with two screw terminated inserts.

MarkingAccessories

Page 44: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

108

1

HBE 32 SURFACE MOUNT BASE WITH DOUBLE LEVERS

HBE 32 PANEL MOUNT BASES WITH DOUBLE LEVERS

TOP ENTRY SIDE ENTRY

Metric hoodsdo not comewith a neck.

All dimensionsare in mm.

All dimensions are in mm.

All dimensions are in mm.

HBE 32 HIGH PROFILE HOODS WITH DOUBLE LEVER BOLTS

Top EntrySide Entry

PG292129

NPT1”

3/4”1”

Metric322532

PGPart #

10.134010.135010.1360

NPTPart #

10.1340NP10.1350NP10.1360NP

MetricPart #

19.134019.135019.1360

Standard Grey CoatingSize of EntryPosition ofCable Entry

StrainRelief

PG NPT M

Standard Grey Coating10.1320

2 Entries1 Entry

PG2929

NPT1”1”

Metric3232

PGPart #

10.138010.1370

NPTPart #

10.1380NP10.1370NP

MetricPart #

19.138019.1370

Standard Grey CoatingSize of Entry# ofEntries

PG29

NPT1”

Metric32

PGPart #

10.1395

NPTPart #

10.1395NP

MetricPart #

19.1395

Standard Grey CoatingSize of Entry StrainRelief

PG NPT M

HBE 32 CABLE COUPLER WITH DOUBLE LEVERS

Page 45: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

109

1TOP ENTRY SIDE ENTRY

Metric hoodsdo not comewith a neck.

HBE 32 PANEL MOUNT BASES WITH DOUBLE LEVER BOLTS

HBE 32 SURFACE MOUNT BASES WITH DOUBLE LEVER BOLTS

Standard Grey Coating10.1323

All dimensionsare in mm.

HBE 32 HIGH PROFILE HOODS WITH DOUBLE LEVERS

All dimensions are in mm.

All dimensions are in mm.

Top EntrySide Entry

PG2929

NPT1”1”

Metric3232

PGPart #

70.205010.1366

NPTPart #

70.2050NP10.1366NP

MetricPart #

79.205019.1366

Standard Grey CoatingSize of EntryPosition of Entry

StrainRelief

PG NPT M

2 Entries1 Entry

PG2121

NPT3/4”3/4”

Metric2525

PGPart #

70.196110.1373

NPTPart #

70.1961NP10.1373NP

MetricPart #

79.196119.1373

Standard Grey CoatingSize of Entry# ofEntries

StrainRelief

PG NPT M

Page 46: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

110

1HBE 32 HOOD WITH SINGLE LEVER BOLTS

HBE 32 PANEL MOUNT BASE WITH SINGLE LEVER

All dimensions are in mm.

Part #10.1320-L

* Please note that these hoods and base are not EP.

Metric hoodsdo not comewith a neck.

All dimensionsare in mm.

Top EntrySide Entry

PG292129

NPT1”

3/4”1”

Metric322532

PGPart #

10.1340SB10.1350SB10.1360SB

MetricPart #

19.1340SB19.1350SB19.1360SB

Black CoatingSize of EntryPosition ofCable Entry

StrainRelief

PG NPT MNPT

Part #10.1340SBNP10.1350SBNP10.1360SBNP

TOP ENTRY SIDE ENTRY

Page 47: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

wwwwww.contactelectronics.com.contactelectronics.com800-221-1451800-221-1451

111

1View from Cable Side

Panel Cut-Out

Panel Cut-Out

Same View fromCable Side as

Screw & CrimpTermination

HBE 48 SCREW & CRIMP TERMINATED INSERTS

Screw Terminated with wire protection (#1-24)Screw Terminated with wire protection (#25-48)Screw Terminated without wire protection (#1-24)Screw Terminated without wire protection (#25-48)Crimp Terminated: Machined (#1-24)Crimp Terminated: Machined (#25-48)

Plug10.196010.204010.196110.204110.186010.1862

Receptacle10.197010.205010.197110.205110.187010.1872

Screwless Cage Clamp (#1-24)Screwless Cage Clamp (#25-48)

Plug10.400310.4005

Receptacle10.401310.4015

HBE 48 SCREWLESS SPRING CAGE CLAMP INSERTS

All dimensions are in mm.

All dimensions are in mm.

Contacts Sold Separately

These inserts fitin the HBE 48

Series Housingswhich are on thefollowing pages.

These inserts fitin the HBE 48

Series Housingswhich are on thefollowing pages.

CrimpContacts areon the next

page.

CRIMP TERMINATEDSCREW TERMINATED

Page 48: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

112

1

Terminal Block: Right Ground (#1-24)Terminal Block: Left Ground (#25-48)

Plug70.306070.3062

Receptacle70.306170.3063

HBE 48 TERMINAL BLOCK ADAPTER INSERTS

TOOLSWIRE GAUGE: 0.5 - 4.0 MM2

Locator11.1472

Crimp Dies11.1471

Crimp Tool11.1470

Removal Tool:11.1825

CONTACTS FOR HBE CRIMP TERMINATED INSERTSHBE MACHINED CONTACTS: DIAMETER 2.5MM

mm2.5

.75 - 1.01.52.54.0

AWG2018161412

StrippingLength

Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3Pin=7.4, Socket =7.3

Pin11.190011.190111.190211.190311.1904

Socket11.195011.195111.195211.195311.1954

Pin11.192011.192111.1922

--

Socket11.197011.197111.1972

--

Silver GoldBags of 100

These terminalblock inserts

only fit in HBE 48panel mount

bases.

View from Cable Side

Two terminal block inserts mate with two screw terminated inserts.

All dimensions are in mm.

Page 49: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

113

1HBE 48 HOODS WITH SINGLE LEVER BOLTS

HBE 48 PANEL MOUNT BASES WITH SINGLE LEVER

TOP ENTRY SIDE ENTRY

Metric hoodsdo not comewith a neck.

All dimensionsare in mm.

All dimensions are in mm.

Top Entry

Side Entry

PG293642293642

NPT1”

1 1/4”-1”

1 1/4”-

Metric324050324050

PGPart #

10.155010.156010.157010.158010.159010.1600

NPTPart #

10.1550NP10.1560NP

-10.1580NP10.1590NP

-

MetricPart #

19.155019.156019.157019.158019.159019.1600

Standard Grey CoatingSize of EntryPosition ofCable Entry

StrainRelief

PG NPT M

Without Dust Cover10.1610

With Dust Coverwith hold down screwsand no dust cover bolts

10.1520

With Dust Coverwith hold down screws

and dust cover bolts10.1525

Page 50: The HBE series inserts are suitable for applications with high … · 2016-02-04 · The HBE series inserts are suitable for applications with high voltages and current. The inserts

114

1HBE 48 SURFACE MOUNT BASES WITH LEVERS

All dimensions are in mm.

2 Entries

1 Entry

2 Entries withdust cover1 Entry withdust cover

PG2936293629362936

NPT1”

1 1/4”1”

1 1/4”1”

1 1/4”1”

1 1/4”

Metric3240324032403240

PGPart #

10.166010.166110.165010.165110.168010.168110.167010.1671

NPTPart #

10.1660NP10.1661NP10.1650NP10.1651NP10.1680NP10.1681NP10.1670NP10.1671NP

MetricPart #

19.166019.166119.165019.165119.168019.168119.167019.1671

Standard Grey CoatingSize of EntryPosition ofCable Entry

StrainRelief

PG NPT M