Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
The complete product range.
Edition 2009
Safety and comfort.
Versatile, convenientand energy efficient.
2 Belimo’s full product range 2009
Belimo has the world’s leading actuator
technology as well as innovative valve
solutions for heating, ventilation and air
conditioning. The complete range of
products from one source combines
highest functionality for your systems
with excellent value for money.
Better performance, more value
Belimo has set standards in the field of
HVAC actuator and valve technology
since 1975 with their consistent orien-
tation to market requirements and
pioneering innovations. Customer wis-
hes are met quickly and flexibly; perso-
nal support is ensured worldwide. Each
actuator is thoroughly tested before
delivery. Specialised know-how and
the proverbial Swiss quality make it
possible to provide a five-year warranty
on the entire product range.
The complete product range
Belimo actuators are suitable for the
motorisation of all controlling elements
in HVAC general air and water solutions.
They are available both with and with-
out emergency control function. Types
that can be parameterised and are bus-
capable can be easily integrated into
superordinate systems. Especially robust
motorisation solutions for fire and smoke
extraction dampers increase safety,
while volumetric flow control systems
provide individual room comfort. Energy
consumption in buildings can be greatly
reduced by using the intelligent Fan
Optimiser for VAV / CAV systems and
the new, tight-closing valve solutions.
We set standards.
Suitable actuators for everyapplication
Belimo’s wide range of actuatorsoffers:• Better performance with lower
energy consumption • Very compact dimensions (CM) with
supercap module connection (SKM)• Extra application options using
linear and rotary actuators• Extremely fast-running actuators
for critical applications (Q series)• Water and dust protection up to
IP67 and corrosion protection (RobustLine)
• Universal retrofit actuators
Increased comfort with greatlyreduced energy consumption
Energy-optimised control of the fans is possible over the MP-Bus® with the Belimo Fan Optimiser for VAV/CAV systems. The damper positions serve as a controlled variable (instead of pressure control). In other words:• Optimised consumption and
operating costs • Reduced flow noise thanks to
lower supply pressure in the air duct system
• Reduced wiring expenses thanks to MP-Bus® network
• Up to 50% reduction in energy consumption
System integration using the Belimo MP-Bus®
Integrating up to eight different HVAC final controlling elements via the Be-limo MP-Bus® cuts costs by:• Simultaneously integrating sensors • Reducing the number of data points • Minimising cabling requirements
Increased safety with motorised fire dampers
Motorised fire dampers with especiallyrobust Belimo fire actuators are state-of-the-art. They provide increasedsafety in buildings and help evacuate people in time. In particular, they offer the following advantages:• Permanent remote monitoring • Simple periodic function testing• Time saving as smoke detectors are
used for tripping (see diagram)
The compact KR rotary actuator has the lowest installation height in the HVAC application. Angle of rotation limiting is easy and robust, which means the valve can adjust the maximum kvs value to the actual value of a chilled beam.• Simple kvs reduction up to 25%• Actuator height < 20 mm • Modulating, 3-point 24 V or 230 V
control• Minimal noise
Very small rotary actuator with very simple angle of rotation limiting
Cost comparison, conventional vs. MP-Bus®
113 (– 90%)1166
Number of data points
Number of cables
36541 (– 88%)
36242 (– 88%)
Conventional
Low-cost solutions withcharacterised control valves
Belimo’s characterised control valves are fitted with the unique, patented characterised disc. This guarantees first-class regulating properties with an equal-percentage characteristic curve for:• Nominal widths from DN 10 to DN 80• kvs values from 0.25 to 90 m3/h• Differential pressures up to 8 bar• Medium temperatures up to 130°C
Example:Sälipark,Olten (CH)
3 Belimo’s full product range 2009
Flash- over
Smouldering fire Fullydevelopedfire
Time / min.
Smoke
Temperature
Number of terminals
4 Belimo’s full product range 2009
General air solutions Water solutions
a Air control damper with actuator g Pressure-independent characterised control valve
b Air control damper with spring-return actuator h Characterised control valve for chilled ceilings
c Fire damper with actuator i Characterised control valve
d VAV-Compact unit j Globe valve (modulating), large globe valves (modulating)
e VAV-Universal dynamic unit k Butterfly valves ON/OFF
a a
b
c
c
dd
e e
gg
h
j j
j
i
k k
i
Total solutions from a single source.
Fan Air heater Air cooler Boiler Pump Speed adjustedpump
Heat exchanger Chiller Chilled waterreservoir
Compact actuators without emergency control functionProduct range Types / rating classes Applications Specifications
CM (2 Nm)CM..G (2 Nm, IP66)
••
Motorisation of air damperswithout emergency control function up to 0,4 m2 for underfloor air conditioning units, decentralised ventilationbalustrade devices etc.
Installation in the smallest spaceMechanical angle of rotation limitation 0...287.5°Rotation without limitsMagnetic gear disengagement
••
••
Rotary actuators without emergency control functionProduct range Types / rating classes Applications Specifications
TMC (2 Nm)LM (5 Nm)NM (10 Nm)SM (20 Nm)GM (40 Nm)
•••••
Motorisation of air damperswithout emergency control function up to 8 m2
Standard mounting and operating elementsWith integrated auxiliary switch or potentiometerIdentical accessories for all types
•
•
•
Linear actuators without emergency control functionProduct range Types / rating classes Applications Specifications
LH (150 N)SH (450 N)
••
Motorisation of control elementswith linear motions up to 300 mm for swirl outlets, long range nozzles, mixing units, cabin units, VAV units etc.
Gear rod lengths 100, 200 and 300 mmMechanical stroke limitation every 20 mm
•
•
Full-rotation actuators without emergency control functionProduct range Types / rating classes Applications Specifications
LU (3 Nm)• Motorisation of control elementswith rotary movement > 90º andVAV units, substitute for KMUactuator
Mechanical angle of rotation limitation up to 330ºRotation without limits
•
•
Super fast-running actuator variants without emergency control functionProduct range Types / rating classes Applications Specifications
Rotary actuators without emergency control function:
LMQ (4 Nm)NMQ (8 Nm)SMQ (16 Nm)
•••
Motorisation of air dampers with-out emergency control function up to 3 m2 for industrial extraction systems, laboratories, painting and welding systems etc.
Standard mounting and operating elementsIdentical accessories for all typesRunning times from 2.5 s / 90°
•
•
•
Linear actuators without emergency control function:
LHQ (100 N)SHQ (200 N)
••
Motorisation of control elementsand slide valves with linear motionup to 100 mm for wood boiler,mixing units, tilt windows etc.
Gear rod length 100 mmMechanical stroke limitation every 20 mmRunning times from 3.5 s / 100 mm
••
•
Rotary actuators with emergency control functionProduct range Types / rating classes Applications Specifications
TF (2 Nm)LF (4 Nm)AF (15 Nm)
•••
Motorisation of air dampers withemergency control function up to 3 m2
Automatic closing function within < 25 s in the event of a power failure
•
Rotary actuators for extreme ambient conditions without emergency control functionProduct range Types / rating classes Applications Specifications
NM..P (8 Nm, IP66/67)SM..P (18 Nm, IP66/67)
••
Motorisation of air control damperswithout emergency control function up to 3.6 m2 in particularly exposed locations:
Protection from aggressive gases, the wet, dampness, high levels of dust and contaminationGeneral exterior applications, wood drying plants, agriculture, swimming pool installations, etc.
•
•
Standard mounting and operating elements with integrated auxiliary switch or potentiometer
Optional:Heating with hygrostatHeating with thermostat
•
••
Compact actuators and supercap module with CPO (controlled power-off) functionalityProduct range Types / rating classes Applications Specifications
CM24K..SKM230A..
••
Motorisation of air dampers with controlled power-off functionality up to 0,4 m2. Ideal in decentralised air conditioning systems or when space is limited
Integrated energy storage function; moves two CM actuators into the closed position within < 15 s in the event of a power failure
•
5 Belimo’s full product range 2009
General air solutions.
6 Belimo’sfullproductrange2009
Motorisationsolutionsforfireandsmokedampers*Product range Types / rating classes Applications Specifications
Actuators:BLF(6Nm)BF(18Nm)BFG(11Nm)
•••
Motorisationofsmallandlargefireandsmokedampers
Steelhousing,formfitManualcontrolwithpositionstopAuxiliaryswitch(1mAto6A)Halogen-freecablesLowpowerconsumptionThermoelectricaltrippingdevicewithtestbuttonandstatusLED
••••••
Communicationandpowersupplyunits:
BKN230-24BKN230-24LONBKN230-24MPBKN230-24-1MP
••••
Controlandmonitoring(variousprotocols):
Standard(2-wirecable)LonWorks®
BelimoMP-Bus®
•••
Slide-onsocketforactuatorStatusLEDConnectionforadditionalsmokedetectorcontact
•••
Communicationandcontrolunits:BKS24-1BBKS24-9A
••
Connectionof1to9dampers:Starwiringtopology2-wirecableInterfacetobuildingmanagementsystemManualoperatinglevel
•••
•
StatusLEDs–Open–Closed–FaultPluggableconnectionsSimpleoperation
•
••
Turnkeysolution:MONICO-1MMONICO-1SBKS24-1MBKS24-1S
••••
Controlandmonitoringoffiredampersinmediumsizedtosmallbuildings
LowwiringexpensesthankstoMP-Bus®technologyPermanentmonitoringAutomatic,periodicfunctiontestingwithloggingOptimalvalueformoney
•
••
•
Motorisationsolutionsforsmokeextractiondampers*Product range Types / rating classes Applications Specifications
Actuators:BLE(15Nm)BE(40Nm)BEG(24Nm)
•••
Motorisationofsmallandlargesmokeextractiondampersinmechanicalsmokeextractionsystems
Steelhousing,formfitManualoverrideAuxiliaryswitch(1mAto6A)Halogen-freecablesLowpowerconsumption1and2-wirecontrol
••••••
Communicationandpowersupplyunit:
BKNE230-24•
Controlandmonitoring:Standard(2-wirecable)•
Slide-onsocketforactuatorStatusLEDCommandmemory
•••
Communicationandcontrolunit:BKSE24-6•
Connectionofupto6dampers:Starwiringtopology2-wirecableInterfacetobuildingmanagementandfirealarmsystemsManualoperatinglevel
•••
•
StatusLEDs–Open–Closed–FaultPermanentmonitoringofvoltagesupplyanddamperpositionsPluggableconnectionsSimpleoperation
•
•
••
*Suppliedtodampermanufactureronly(withtheexceptionofcommunicationandcontrolunits).
Safetysolutions.
7 Belimo’s full product range 2009
VAV-Compact controllers*Product range Types / rating classes Applications Specifications
LMV-D2-MP (5 Nm)NMV-D2-MP (10 Nm)SMV-D2-MP (20 Nm)LHV-D2-MP (150 N)LMV-D2LON (5 Nm)NMV-D2LON (10 Nm)
••••••
Types with linear or rotary motionto control VAV and CAV units for airvolume control systems in buildings
Compact unit with sensor, controller and actuator On-site operation using ZTH-VAVSimple commissioning using PC-Tool, incl. trend functionSimple integration in MP-Bus® or LonWorks® networks
•
••
•
VAV-Universal solutions*Product range Types / rating classes Applications Specifications
VAV-Universal controller:VRD3 with integrated sensorVRP with static sensorVRP-M with static sensor
•••
Control of VAV and CAV units in buildingsVAV lab applicationsPressure or volumetric flowFast-running variant
•
•••
Simple handlingPlug-and-socket connections between sensor, controller and actuatorWide range of peripheral devices
••
•
VAV-Universal pressure sensor(static):
VFP100 / ...300 / ...600 (pressure ranges 100...600 Pa)
•
For heavily polluted air oraggressive gases:Use in conjunction withVAV-Universal controllers
Plug-and-socket connections for VRP
•
Actuators:LM, NM, SM series (5...20 Nm) Fast-running variant LMQ /NMQ (4 /8 Nm)LF and AF series spring return actuators (4 /15 Nm)
••
•
Use in conjunction withVAV-Universal
No wiring needed due to plug-and-socket connectionsWide coverage thanks to different motor variantsRunning time from 2.5 s
•
•
•
Fan controlProduct range Types Applications Specifications
COU24-A-MP• Optimiser system solution forregulating frequency converter-controlled fans in VAV/CAV systems
Energy efficientMP-Bus® connection for VAV-Compact, VRP-M0...10 V frequency converter output signal and 0...10 V control of room temperature controller or via DDC with MP-Interface
••
•
Room controller system solutionsProduct range Types / rating classes Applications Specifications
Room controllers:With operation: CR24-B..Without operation: CR24-A..
••
Single-room control systems incomfort range for:
VAV or air control dampersWater or electric reheatersChilled ceilings or recoolersCombined systems
••••
Modern design Complete solutionHigh functionalitySimple operationEnergy efficient (eu.bac certified)Minimum engineering, commis-sioning and maintenance costs
••••••
Controllers for apartments:With operation: CRA24-B3With covered setpoint adjust-ment: CRA24-B3P
••
Room controller for controlled ventilation of apartments:
VAV or air control dampersHeating valve
••
Optimised applicationApplication-specific override functionsSimple operation
••
•
Controller for 6-way valve:With operation: CRK24-B1•
Room temperature controller for chilled / heated ceilings:
in combination with the 6-way characterised control valve
•
VAV toolsType Specifications Type Specifications
Simple diagnostics of VAV units for commissioning and main-tenanceConvenient setting optionsGraphical illustration of setpoint, volumetric flow, damper setting etc.
•
••
Simple, rapid setting of VAV unit parametersEfficient handlingDiagnostics functionOne tool for all VAV devicesReverse compatible with all Belimo PP/MP devices produced since 1992
•
••••
* Supplied to damper manufacturer only (with the exception of communication and control units).
Room and system solutions.
PC-Tool MFT-P ZTH-VAV hand-operated device
Characterised control valvesProduct range Valves Applications Actuators
Internal thread:R2 (2-way)R3 (3-way)
External thread:R4 (2-way)R5 (3-way)
••
••
Cold, warm and domestic water:Nominal widths DN 10...50Permissible pressure [kPa]: 4140...2760
••
Rotary actuators: TR(D), LR(D), NR, SR seriesWith emergency control function: TRF(D), LRF, ARF seriesFast-running variants: TRC(D), LRC(D), NRC seriesSuper fast-running variants: LRQ(D), NRQ seriesNew: KR.. up to DN 20
•
•
•
•
•
Flange:R6..R (2-way / PN6)R7..R (3-way / PN6) for DN 15…50
••
Cold, warm and domestic water:Nominal widths DN 15...80 (2-way)Permissible pressure [kPa]: 600
•
•
External thread: R4..D (2-way)
District heating, domestic anddrinking water:
Nominal widths DN 10...20Permissible pressure [kPa]: 2760
••
Pressure-independent characterised control valveProduct range Valves Applications Actuators
Internal thread: R2...P (2-way)•
Shut-off, throttling and control inone valve:
Flow V· [l/s]: 0.09...5.05Nominal widths DN 15...50Permissible pressure [kPa]: 4140...2760
•••
Rotary actuators: LR, NR, SR seriesWith emergency control function: TRF, LRF, ARF seriesFast-running variants: TRC, LRC seriesSuper fast-running variants: LRQ, NRQ series
•
•
•
•
Globe valvesProduct range Valves Applications Actuators
External thread:H4..B (2-way)H5..B (3-way)
••
Cold, warm and domestic water:Nominal widths DN 15...50Permissible pressure [kPa]: 1600
••
Linear actuators: NV (20 mm), AV (40 mm)With emergency control function: NVF (20 mm)Fast-running variants: NVY (20 mm), AVY (40 mm)Actuator for large globe valve: GV (65 mm)
•
•
•
•
Flange:H6..N (2-way / PN16)H7..N (3-way / PN16)H6..S(P) (2-way / PN16) for hot water and steamH6..W..S7 (2-way / PN16), DN 200/250H7..W..S7 (3-way / PN16), DN 200/250
•••
•
•
Cold and heating water:Nominal widths DN 15...250Permissible pressure [kPa]: 1600
••
Flange:H6..R (2-way / PN6)H7..R (3-way / PN6)
••
Nominal widths DN 15...100Permissible pressure [kPa]: 600
••
Shut-off and change-over valvesProduct range Valves Applications Actuators
Internal thread:R3..BL (3-way)Shut-off ball valve R..
••
“Change over” functions:Nominal widths DN 15...50Permissible pressure [kPa]: 4140...2760
For shutting off cold, warm and domestic water:
Nominal widths DN 15...80Permissible pressure [kPa]: 4140...2760...600
••
••
Rotary actuators: TR, LR, NR, SR series With emergency control function: TRF, LRF, ARF series
•
•
Flange:D6..N (2-way, PN6 /10 /16)•
For shutting off cold, warm and domestic water:
Nominal widths DN 25...350•
Rotary actuators: SR-5, GR-5, GR-7, DGR-7, SY seriesWith emergency control function: ARF-5
•
•
RobustLine actuatorsProduct range Valves Applications Actuators
Characterised control valves R...Open-close ball valves
••
Applications in IP66 / 67 environments:
Nominal widths for R..: DN 10...80Nominal widths for D6..N: DN 25...80
•
•
Rotary actuators: SR..P series
Optional:Heating with hygrostatHeating with thermostatIntegrated auxiliary switch or potentiometer
•
•••
Butterfly valves D6..N•
* Motorisation of valves from different manufacturers.
Water solutions.
8 Belimo’s full product range 2009
9 Belimo’s full product range 2009
Retrofit actuators without emergency control functionProduct range Types / rating classes Applications Specifications
LM24A-MF-TP (5 Nm)NM24A-MF-TP (10 Nm)SM24A-MF-TP (20 Nm)SM24A-R9 (20 Nm, 0...135 Ω)SM24A-PC (20 Nm, 0...20 V phase cut)SM24A-MA (20 Nm, 4...20 mA)LH24A-MF60-TPLH24A-MF100-TPLH24A-MF200-TPLH24A-MF300-TP
•••••
•••••
Replacement actuators for airdampers without emergency control function up to 4 m2
MF types are freely program-mable and can be perfectly adapted to the applicationIdentical accessories such as auxiliary switch and potentio-meter for all rotary actuatorsIdentical accessories such as rotary support and coupling pieces for all linear actuators
•
•
•
Retrofit general air solutions.
Globe valvesProduct range Valves Applications Actuators
Globe valves from variousmanufacturers
Motorisation of globe valves withnominal widths DN 15...150
NV.. linear actuators with valve-specific UNV (bracket and valve/stem adapter)AV..R linear drives with valve-specific ZAV (valve adapter) NRDVX short-stroke actuators with Siemens or Cazzaniga adapters
•
•
•
Rotary valvesProduct range Valves Applications Actuators
Rotary valves from variousmanufacturers:
Characterised control valvesShut-off ball valvesButterfly valveMixing valves
The torque should be tested if necessary
••••
Interface ISO 5211: F03/F04/F05/F07 or F10Nominal widths from DN 350: on request
•
•
Rotary actuators with adapter (square, double, wedge): SR-R, GR-R (up to 40 Nm)With emergency control function: AF with adapter (square, double, wedge)SY rotary actuator: 35, 90, 150, 400, 500 NmMotorisation > 500 Nm: on request
•
•
•
•
Retrofit water solutions.
For MFT / MFT2 / MF / MP actuatorsType Specifications Type Specifications
Convenient adaptation of the actuator to specific applications by parameterisingSimple diagnostics for commis-sioning and maintenanceGraphical illustration of setpoint, actual value and stroke
•
•
•
MFT adjustment tool ZTH-GEN Simple handlingEfficient setting of actuator parametersDiagnostic and test functionsConnection to the actuator, CR24 room controller or control cabinet
••
••
Retrofit tools.
PC-Tool MFT-P
All-inclusive.
Belimo worldwide: www.belimo.com
EN
G –
930
01–0
1150
– 0
2.09
– 1
M –
Prin
ted
in S
witz
erla
nd –
KS
AG
– S
ubje
ct t
o te
chni
cal c
hang
es
5 year warranty
On site around the globe
A complete range of products from one source
Tested quality
Short delivery times
Comprehensive support
Headquarters
BELIMO Holding AGBrunnenbachstrasse 1CH-8340 HinwilTel. +41 (0)43 843 61 11Fax +41 (0)43 843 62 [email protected]
Subsidiaries, Representatives and Agencies
ArgentinaAustralia AustriaBahrainBelgiumBosnia-HerzegovinaBrazilBulgariaCanadaChileCroatiaCyprusCzech Republic
DenmarkEgyptEstonia FinlandFrance Great Britain Germany GreeceHong KongHungaryIcelandIndiaIndonesiaIrelandIsraelItaly JapanJordanKuwaitLatvia
LebanonLiechtensteinLithuania LuxembourgMalaysiaMexicoMoroccoNetherlandsNew Zealand NorwayOmanPakistanPeople’s Republic of ChinaPhilippinesPoland PortugalQatarRepublic of Korea (South Korea)
RumaniaRussia Saudi ArabiaSingaporeSlovakiaSloveniaSouth AfricaSpainSwedenSwitzerlandTaiwanTurkeyUkraineUnited Arab Emirates United States of America