Telford Copper Cylinders is a family run business which began trading in 1989 from the premises it still occupies today. The original factory has been extended on a number of occasions since then to keep up with the increased demand for its products.

From the beginning Telford set out to manufacture a broad range of cylinders. Our copper division has developed from manufacturing traditional vented cylinders to now include commercial calorifiers and the award winning advanced Thermal Store units, which are available as manual fill, “Washing Machine”, solar recovery and under-floor heating variants.

In 2002, responding rapidly to changing market expectations we began to manufacture our popular Tempest and Tornado unvented cylinders in stainless steel, all of our domestic unvented cylinders are now formed from Duplex 2304 Stainless Steel, continuing our philosophy of using only the finest materials. We are so confident of the construction that we offer a lifetime guarantee* on the Tornado and Tempest models.

Our vented, unvented and thermal store cylinders have been developed to maximise the benefits of free solar energy and proven environmentally friendly alternative sources.

As the market for plumbing and water storage cylinders has changed Telford Copper Cylinders have adapted to ensure we are always at the cutting edge of technology, making new products without compromising our first principal of quality. We also have a commitment to offer a professional after care service, which includes dedicated personnel as well as nationwide support through our team of sales engineers.

*Please contact Telford Copper Cylinders for guarantee details

Welcome to Telford Copper and Stainless Cylinders

2

TCC Final.indd 2 1/6/09 15:14:35

Page 3: THE COMPLETE COLLECTION

Selecting Your Cylinder

Index Table

Dom

estic Hot W

ater Cylinders

Hot Water Demand Bedrooms Gas Oil Indirect Electric Direct

1 STANDARD BATHOR SHOWER

Bedsit / 1 bed2-3 bed3-4 bed

60/90/100125150

150170200

1 STANDARD BATH 2 - 3 bed3 - 4 bed

125125

200200

1 BATH & EN SUITE 2 - 3 bed3 - 4 bed 4 - 5 bed

150150170

200200200

2 STANDARD BATHS 2 - 3 bed3 - 4 bed 4 - 5 bed

170170200

200200250

3 BATHROOMS 3 - 4 bed4 - 5 bed5 - 6 bed

250250300

300300300

These recommendations are based on guidelines in BS 6700Guidance should be sought for unusual applications e.g. high flow rate showers.

3

Selecting your cylinders 3-4

Domestic hot water cylinders 5

Tappings charts 6

Typhoon CR 7

Standard vented specification 8

Combination tank 10

Maxistore cylinders 11

Trident 12

Calorifiers 13

Stainless steel vented 14

Thermal store 15

How a thermal store works 16

Tristor manual fill 17

Tristor and Tristar standard dimensions 18-19

Technical notes and guarantee 20

Stainless steel unvented cylinders 21

Material specification 22

Installation 23

Technical specification Tornado 24-25

Technical specification Tempest 26-27

Variants 28

Alternative energy 29

Tempest solar cylinders 30-31

Tristor renewable 32

Vented copper and stainless solar cylinder 33

The Telford complete solar system 34

Solar panel guides 35

Tristor heat pump 35

Eco air heating system 36-37

Parts 38-39

TCC Final.indd 3 1/6/09 15:14:36

Page 4: THE COMPLETE COLLECTION

Selecting your Cylinder Continued

Selecting the correct size of cylinder requires consideration of a number of variables, including the volume of water needed, the energy source and the space available. Calculating the volume needed can be achieved by adding together the individual volumes of each appliance that uses hot water and how frequently it is used. The energy source is the next variable to consider, as it will have a direct impact on the cylinder size. All indirect cylinders have coils which are designed to allow the contents to be heated up in less than 25 minutes, given an adequate boiler size. High performance products, such as TyphoonCR reduce this time dramatically and can be used to reduce the cylinder size where space is at a premium. Care should be taken in selecting the cylinder size for electrically heated cylinders, as these are slower to recover and often utilise low tariff supplies during the night. The use of the boost immersion heater during the day is expensive and should be avoided where possible. Telford Copper Cylinders, as a member of the Hot Water Association, has been working to establish a simple to use hot water volume calculator. In our research we determined that there were four principle types of user, and two levels of consumer expectation. The table below suggests recommended storage volumes for these options. Telford Copper Cylinders can provide a design service for all types of development. Please contact our Technical Helpline for assistance or to request your copy of the Hot Water Calculator.

Shower Only Shower or Bath

Shower and Bath

Two Baths

GOOD PRACTISE 80 140 180 210

BEST PRACTISE 120 140 210 250

STANDARD BATH 70 LITRESLARGE OR CORNER BATH 130 LITRESSHOWER (BASED ON 5 MINUTE DRAW OFF) 45 LITRESPOWER SHOWER OR SHOWER WITH LARGE HEAD (BASED ON 5 MINUTES) 75 LITRESWASH BASIN 7 LITRESKITCHEN SINK 12 LITRES

1. The volumes in the table are the hot water requirements at 60°C, and assume a cold water blend for showers to reach a useable temperature of 48°C.2. Dishwashers and washing machines are generally cold feed and can be ignored from this calculation.

1. The user types depend upon the bathroom designs in the house. For example a house with a single bath and over shower fits into the category of “Shower or Bath” as it is not practical for the bath and shower to be running simultaneously. At the extremes it is possible in a larger house for two baths to be run either together or in quick succession.2. The recommended volumes assume that the bath is a standard size. The cylinder size would need increasing if larger baths are used.3. Good Practice is the minimum suggested level to give consumer satisfaction. If high performance products are being used, or power showers, we would recommend that Best Practice is adopted.

4

TCC Final.indd 4 1/6/09 15:14:36

Page 5: THE COMPLETE COLLECTION

Standard Vented Cyinders

Domestic Hot Water Cylinders

Dom

estic Hot W

ater Cylinders

INDIRECT

Designed to be linked to a remote heat source, such as a gas boiler or coal fi re. The water within the central heating system is heated by the remote heat source and is passed through the coil in the cylinder. As the primary normally operates at around 80°C, the heat is exchanged into the cylinder and warms the domestic water. Manufactured and fully approved to the latest British Standard specifi cation BSI566:2002 (Part L).

DIRECT

When the only energy source available is electricity, a Direct pattern cylinder is the ideal product. The domestic water is “directly” heated by the immersion heaters which sit inside the cylinder, however, the heat-up and recovery times take longer than an Indirect cylinder. Manufactured and fully approved to the latest British Standard specifi cation BSI566:2002 (Part L).

SINGLE FEED

A single feed cylinder incorporates a multipurpose heat exchanger. As well as heating the domestic water it also acts to top up the heating circuit, i.e. radiators. As only one cold-water cistern is used to feed the cylinder (including the heating circuit) we refer to it as a single feed Indirect cylinder.

5

TCC Final.indd 5 1/6/09 15:16:20

Page 6: THE COMPLETE COLLECTION

Tappings Charts

Direct

Indirect

A1

IDA2

IDF2

IDD2

IDF3

IDE1

IDH1

IDE2

IDH2

IDF1

IDH3

A4

G1

C1

G3

C4

G4

F1

F4

6

TCC Final.indd 6 1/6/09 15:16:37

Page 7: THE COMPLETE COLLECTION

Corrosion resistant technology is at the heart of this revision to the TyphoonCR product range. Originally designed as an ultra-rapid recovery cylinder it allows plumbers to install small cylinders as a space saving option, without losing performance.

TyphoonCR includes corrosion resistant technology, this enables Telford to offer a 5 year guarantee on this product.

Heat Up Times

TF45 TF80 TF95 TF100 TF115 TF120 TF140 TF160 TF200

Min

utes

Predicted heat up times for cylinder based on test procedures defi ned in BS1566:2002 for type P ctylinders.

Whilst sacrifi cial anodes remain an option on the standard product range, they cannot be specifi ed on Typhoon CR.

Typhoon CR

Dom

estic Hot W

ater Cylinders

TF45 TF80 TF95 TF100 TF115 TF120 TF140 TF160 TF200

Diameter 350 400 450 400 400 450 450 450 450

Height 600 750 750 900 1050 900 1050 1200 1500

Capacity 45 80 95 96 114 117 140 162 206

5

YEAR

7

TCC Final.indd 7 1/6/09 15:16:44

Page 8: THE COMPLETE COLLECTION

Standard Vented Specifications

Notes: BS1566:2002 has within its scope both Indirect and Direct cylinders. Cylinders are designated as type D for Direct, G for Indirect cylinders suitable for both gravity and pumped primaries and type P for cylinders which are only suitable for pumped primary systems. Type P cylinders are new to the standard and are often high performance products offering improved performance over the G type. Within the Telford Copper Cylinder range, ref 2-11 are type G cylinders and suitable for both gravity and pumped primaries. Ref 0-1 and 12-14 are for pumped primaries only. Special cylinders are available should you require these sizes for gravity circulation primaries. Single feed, self-priming units must not be used on pumped primary systems.

1. The working head is the vertical distance from the bottom of the cylinder to the line of the cistern supplying it (1m water = 0.1 bar approximately).

2. Secondary return fitted only when ordered by the purchaser.

3. Class B external threads may be applied when ordered.

4. Storage capacity is shown for Indirect models only and does not include the water content of the primary heater.

Direct models contain a small amount of extra water.

5. P = preferred location for off-peak / electric water heating immersion heater.

The company reserves the right to change specifications without notice as part of its policy of continuous improvement.

Dimensions and Details

A

H

PP LL

B

A

230m

mB

L

140m

m

A

J

M

HB

In-direct Direct Single Feed

8

TCC Final.indd 8 1/6/09 15:16:47

Page 9: THE COMPLETE COLLECTION

Dom

estic Hot W

ater Cylinders

Type Reference

External Diameter

Minimum Height

Nominal Storage Capacity

Minimum Heating Area for Type G Cylinders

Min

imum

Nom

inal

Thi

ckne

ss o

f Cop

per

Size of Primary Heater

Pre

ferr

ed H

eigh

t of C

onne

ctio

ns A

bove

Dat

um

Preferred Size of Secondary

Connections

Preferred Size of Primary

Connections

Gra

de 1

Gra

de 2

Gra

de 3

Test

Pre

ssur

e

3.65

bar

Test

Pre

ssur

e

2.20

bar

Test

Pre

ssur

e

1.45

bar

Secondary Return

H

Primary Return

J

Cold Feet

L

Primary Flow

M

Immersion Heater Boss

P

Max

Wor

king

H

ead

25m

Max

Wor

king

H

ead

15m

Max

Wor

king

H

ead

10m

Con

cave

B

otto

mR

est o

f S

hell

Con

cave

B

otto

mR

est o

f S

hell

Con

cave

B

otto

mR

est o

f S

hell

mm

mm

Lm

2m

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

m

0 1 2 3

300

350

400

400

1600

900

900

1050

96 72 96 114

0.42

0.32

0.42

0.50

1.6

1.6

1.8

1.8

1.2

1.2

1.2

1.2

1.6

1.6

1.6

1.6

0.9

0.9

0.9

0.9

1.6

1.6

1.6

1.6

0.7

0.7

0.7

0.7

22 22 28 28

1250

700

700

800

100

100

100

100

100

100

100

100

540

400

400

470

150

150

150

150

G1

G1

G1

G1

G1B

G1B

G1B

G1B

4 5 6 7

450

450

450

450

675

750

825

900

84 95 106

117

0.37

0.48

0.53

0.61

2.0

2.0

2.0

2.0

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.0

1.0

1.0

1.0

1.6

1.6

1.6

1.6

0.7

0.7

0.7

0.7

28 28 28 28

450

550

625

700

100

100

100

100

100

100

100

100

300

340

370

400

150

150

150

150

G1

G1

G1

G1

G1B

G1B

G1B

G1B

8 9 9E 10

450

450

450

500

1050

1200

1500

1200

140

162

206

190

0.70

0.88

0.90

1.05

2.0

2.0

2.0

2.5

1.6

1.6

1.6

1.8

1.6

1.6

1.6

1.8

1.0

1.0

1.0

1.2

1.6

1.6

1.6

1.6

0.7

0.7

0.7

0.9

28 28 28 35

800

950

1200

950

100

100

100

150

100

100

100

150

470

540

620

540

150

150

150

200

G11/

4

G11/

4

G11/

4

G11/

2

G1B

G1B

G1B

G11/

4 B

11 12 13 14

500

600

600

600

1500

1200

1500

1800

245

280

360

440

0.87

1.32

1.68

2.04

2.5

2.8

2.8

2.8

1.8

2.0

2.0

2.0

1.8

2.5

2.5

2.5

1.2

1.4

1.4

1.4

1.6

2.0

2.0

2.0

0.9

1.2

1.2

1.2

35 35 35 35

1200

950

1200

1350

150

150

150

150

150

150

150

150

670

540

670

800

200

200

200

200

G11/

2

G2

G2

G2

G11/

4 B

G11/

2 B

G11/

2 B

G11/

2 B

Dim

ensi

ons

are

for u

se a

s gu

idel

ine

only

.

Dimensions and Details

9

TCC Final.indd 9 1/6/09 15:16:48

Page 10: THE COMPLETE COLLECTION

Combination Tank

Combination units have been designed to combine the cold water feed and the hot water cylinder into one unit. There are many benefi ts to installing a combination style cylinder, including reducing labour time when installing the product and freeing up valuable roof space. The incoming supply is connected directly to the top section, this in turn feeds the bottom(hot) section when water is drawn from the hot tap. Our combination cylinders are manufactured to BS3198 and can be ordered as Direct or Indirect variants.

The insulation of the division between hot and cold water sections ensures that heat transfer is minimal and easily meets the requirements of BS 3198:1981 Standard. All cylinders are factory insulated with Envirofoam - 100% C.F.C. free as standard.

Comb ref.Bs 3198 type

External diameter

External height

Nominal capacity hot

section

Nominal capacity cold

section

Heatingsurface

mm mm mm litres litres mm

DIRECTINDIRECT

450450

900900

9085

2020

-0.53

DIRECTINDIRECT

450450

10501050

120115

2020

-0.61

DIRECTINDIRECT

450450

12001200

120115

2020

-0.61

DIRECTINDIRECT

450450

14001400

144140

4040

-0.79

DIRECTINDIRECT

450450

18501850

210206

4545

-1.05

Dimensions and Details of Copper Direct and Indirect Combinations Tanks

Dimensions are for use as guideline only.

10

TCC Final.indd 10 1/6/09 15:17:45

Page 11: THE COMPLETE COLLECTION

Dimensions and Details of Copper Direct and Indirect Maxistore Combination Tanks

Dimensions and Details of Copper Direct and Indirect Maxistore Cylinders

Dia Height Cap H J L M P R

450 900 120 700 100 100 475 150 600 IND500 DIR

450 1050 144 800 100 100 545 150 650

450 1500 210 1200 100 100 695 150 1100

Dia HeightCapC/H

HtgArea A B C D E F

450 1200 115/40 0.44 705 90 100 475 160 500

450 1400 144/50 0.52 850 90 100 545 160 650

450 1850 210/45 0.79 1305 90 100 695 160 1100

Maxistore Cylinders

Dom

estic Hot W

ater Cylinders

Dimensions and Details of Copper Direct and Indirect Combinations Tanks

Maxistore was developed for use on an open-vented system in electric only applications. The cylinders carry full Economy 7 accreditation and are manufactured to BS1566:2002 (Part L).To ensure maximum efficiency the cylinder is foamed twice, which reduces the heat-loss values. Two side entry immersion heater connections are fitted as standard to maximise the use of Economy tariff electricity.

Later versions of the Maxistore range incorporated a combination-style variant, to remove the need for a feed tank in the roof space and ease installation. Telford Copper Cylinders can also supply, as a cost option, suitable immersion heaters and economy tariff timeclocks. These can be supplied either factory fitted or supplied separate for on-site installation.

Dimensions are for use as guideline only.

Dimensions are for use as guideline only.

H

P L

MR

J

A

E

DF

CB

11

TCC Final.indd 11 1/6/09 15:18:23

Page 12: THE COMPLETE COLLECTION

Trident

Conventional plumbing systems require a separate cold water storage tank in addition to feed and expansion tanks. These tanks normally take up valuable roof space. The Trident cylinder removes the need for this by incorporating them within the cylinder. The appearance is similar to a combination unit, but also includes the feed tank to supply the central heating system.The time required to fit a Trident system is approximately three hours compared to around eight to install a conventional system.The number of fittings and materials needed for the installation are reduced dramatically and the only component required is the cylinder itself.

As with all combination cylinders the rate of flow 1. from a hot water tap is dependent on the height of the tank above the tap. The water level should be 1 metre above the highest hot water tap.

A minimum clear space of 205mm should be left 2. above the unit to allow access to the ball-valve for servicing and adjustment.

22mm (G 3/4) overflow fittings are supplied fitted.3.

A 15mm (G 1/2) threaded boss for a drain cock is 4. fitted. Drain cock not supplied.

The unit should be installed in such a way that the 5. immersion heater can be withdrawn for servicing.

Capacity - Litres Nominal Dimensions (mm)

115 HOT/40 COLD

144 HOT/45 COLD

115 HOT/115 COLD

1280 x 350

1400 x 450

1470 x 500

Dimensions are for use as guideline only. Othersizes available upon request

12

(foamed as standard)

TCC Final.indd 12 1/6/09 15:18:26

Page 13: THE COMPLETE COLLECTION

Coil Heater Units

Removable U-Type Battery Units

Calorifiers

Telford Copper Cylinders have introduced a range of Calorifiers for commercial and industrial applications. Available as Direct and Indirect variants, in capacities from 280 to 4500 litres. The cylinders are constructed from copper to the requirements of BS2870/1 deoxidised.

Coil heater units or removable U-type batter units can be specified as shown. Immersion heaters can also be supplied to order. All Calorifiers are supplied with certified drawings and Test Certificates. Shells and heater units are fully tested prior to despatch to at least 11/2 times the normal working pressure.

These units conform to BS853 and can be supplied with a variety of connections. Hot water or steam can be pumped or gravity fed through the circuit.

Battery units conform to BS853/2/81, BS3274 and M&E No.3 specification. They are suitable for medium temperature water, low-pressure hot water or steam.

Dom

estic Hot W

ater Cylinders

B

B

A

A

B

B

A

A

13

TCC Final.indd 13 1/6/09 15:18:29

Page 14: THE COMPLETE COLLECTION

Stainless Steel Vented

Stainless Steel Vented Cylinders

Capacity Height Diameter

150 1050 450

170 1200 450

200 1500 450

250 1500 500

In areas where water quality is especially aggresive we have developed a vented cylinder from stainless steel. Because of the superior anti-corrosive characteristics of Duplex stainless steel the benefits over a standard copper cylinder are significant. The unit is available white cased or foam lagged.

Dimensions are for use as guideline only.The minimum volume of stainless steel vented cylinder is 90L.

14

TCC Final.indd 14 1/6/09 15:18:35

Page 15: THE COMPLETE COLLECTION

Thermal Store

For at least twelve years we have been manufacturing and supplying our range of “thermal stores” under the brand names of Tristar™ and Tristor™, we started with three different models; Combination, Open Vented, & Sealed System for both boiler application and fully electric. We now have over 100 models and can offer “Bespoke Design & Size” on all units.

All of our thermal stores can be manufactured to accept any heat source that is currently available including Solar and range cookers.

Tristar and Tristor can be manufactured to suit both “Active” and “Non-active” heating applications (see technical notes for explanation) and from fully pumped systems to zone control and underfloor systems.

Over the years research and development in partnership with others has led to the development of many variants to meet specialist requirements; including OEM models for use in the underfloor heating and solar gain markets. These can, on request, be branded with the customer’s name. Recently we have developed, in conjunction with a major house builder, a thermal store unit that has provision for a washing machine under the unit and is supplied with plumbed washing machine leak detection and failsafe water protection. This has proved popular with insurance companies and developers of multi-storey properties alike. Another very popular system we have developed requires no overflow or discharge pipe work on installations, ideal where access to a suitable discharge point is difficult or impossible.

The added advantage of thermal store mains pressure installations is that the installer does not require special qualifications, plus Telford Copper Cylinders will provide first class technical backup and customer support.

TRISTAR™

This unit is the workhorse of the Telford thermal store cylinder range. The original design is over

twelve years old and has proven itself in many applications. It remains a specifiers favourite due

to its size, replacing old systems in small airing cupboards.

TRISTOR™

Our most recent unit is a market leading thermal store which delivers hot water to meet modern living styles. Extensive research went into designing and producing this model, it has an attractive white case and is without doubt the best performing thermal store in its class.

Thermal Stores and Heat Stores

Thermal Stores

15

TCC Final.indd 15 1/6/09 15:18:39

Page 16: THE COMPLETE COLLECTION

How a Thermal Store Works

The water in the cylinder ‘the store’ is heated to and maintained at 76°C by the heat source which can be a boiler, immersion heater or solar (optional).

Cold water at mains pressure is fed through a heat exchanger in ‘the store’ (a high efficiency coil). The heated water is blended with cold mains water and supplied to the taps at a thermostatically controlled 51°C.

This system is highly efficient; heat loss is kept to minimum due to the high density CFC free foam installation.

Running costs are low because you only heat the water you use.

The key to using a thermal store in the most cost effective and efficient manner is to maintain ‘the store’ temperature at a constant 76°C by means of the chosen heat source.

This will ensure that ‘instant’ hot water, at mains pressure, is available whenever required; no waiting for the cylinder to heat up.

Minimal heat loss when the thermal store is at rest keeps ‘the store’ temperature maintenance costs low.

Thermal stores do not require G3 Building Control Notification and unlike other stored mains pressure systems no special qualifications are required to install the unit.

Mains pressure hot water to taps thermostatically controlled at 51°C

Thermostatic mixing valve

High efficiency coil for rapid heat transfer to incoming mains cold water.

Mains cold water in

HOT WATER STORED AT 76°C

FEED AND EXPANSION

16

TCC Final.indd 16 1/6/09 15:18:40

Page 17: THE COMPLETE COLLECTION

Bespoke and Special Units

Tristor Manual Fill

This thermal store has been designed for fi tting in situations where the running of an overfl ow or discharge pipe would be diffi cult or impractical. The fi lling of the unit is achieved by integral fi lling loop which is disconnected from the mains water when the correct water level is attained.

The entire system is protected from fl ooding with the unique overfi ll device fi tted as standard. At the heart of this unit is the same Tristor™ technology for proven hot water performance.

MULTI-INPUT THERMAL STORES FOR UNDERFLOOR HEATING

In conjunction with a major designer and installer of specialist thermal stores we have developed a high performance range which satisfi es the requirement to integrate condensing boiler technology with energy from renewable sources.

It solves the major problem of very low heat demands in modern well insulated buildings. This causes even the most advanced gas boiler to cycle on and off, greatly reducing effi ciency by running the boiler out of condensing mode’. This problem is even more serious with oil boilers as their output cannot be regulated.

Designed as a Thermal store it has an extremely high recovery rate enabling it to produce an almost unlimited supply of domestic hot water. Because it stores cooler water in the lower part it supplies water for underfl oor heating directly without mixing sets thus increasing the effi ciency of the whole system.

Special versions are available for heatpumps with or without the addition of a boiler. By incorporating sealed system coils input from solar panels, wood burners, kitchen ranges and wind turbines can be accommodated.

The ability to control a number of heat sources provides the unique ability to optimise energy use and greatly reduces the running costs of the whole system.

• UniqueOverfill™protectiondevice• Uniquedesign• Nooverflowordischargerequired• HighFlowRates• Thermostaticallycontrolledhotwater@51°C• Easytoinstallandcommission• Highlyefficient-lowheatloss• Easytomaintain

Thermal Stores

17

TCC Final.indd 17 1/6/09 15:18:44

Page 18: THE COMPLETE COLLECTION

Tristor and Tristar Standard Dimensions

TSC Height Overall Diameter

150200280

140017502000

510510555

TSC Height Overall Diameter

115144160210

1050140015501850

550550550550

Tristor - Cased

Tristar - Foamed

All thermal stores come complete with shock arrestor, immersion heater(s) and blend valve. This is just a selection of our standard sizes. If you require a specialised size please contact Telford Copper Cylinders

Heat Source Options

Heat Source Options

HOT WATER ONLY Heat Supplied by Boiler, with Back Up Immersion Heater

ALL ELECTRIC For use wih low tariff supplies. Supplied with 2 x 3kw immersion heaters

DUAL SOURCE INDIRECT Suitable for use with solar fuel and wood buring stoves. Can be adapted for use on direct schemes.

HEAT PUMP Eco friendly heat pump supplemented from boiler source. Supplied with back up immersion heater.

HOT WATER STORED AT 76°C

FEED AND EXPANSION

18

TCC Final.indd 18 1/6/09 15:18:44

Page 19: THE COMPLETE COLLECTION

Tristor and Tristar Standard Dimensions

TSV Height Overall Diameter

115144160210

900105012001500

550550550550

TSS Height Overall Diameter

115144160210

900105012001500

550550550550

TSV Vented

TSS Sealed System

THP Height Overall Diameter

150200

18201820

510554

Tristor HP (THP)

Thermal Stores

Tristor - Cased

Tristar - Foamed

Heat Source Options

Heat Source Options

HOT WATER ONLY Heat Supplied by Boiler, with Back Up Immersion Heater

ALL ELECTRIC For use wih low tariff supplies. Supplied with 2 x 3kw immersion heaters

DUAL SOURCE INDIRECT Suitable for use with solar fuel and wood buring stoves. Can be adapted for use on direct schemes.

HEAT PUMP Eco friendly heat pump supplemented from boiler source. Supplied with back up immersion heater.

19

TCC Final.indd 19 1/6/09 15:18:45

Page 20: THE COMPLETE COLLECTION

Technical Notes and Guarantee

TECHNICAL NOTES:

THE TERMS Active and Non Active refer to the connections and operation of the thermal store. For example a non-active store is only capable of providing a supply of mains pressure hot water through the mains coil and would be heated either by pumped heating system through a zone valve or in the case of an electric version by the immersion heaters (two immersions supplied as standard). An active thermal store is one which also provides a heating demand such as the unit favoured by the underfloor heating market. This unit provides lower temperature water for the heating system which can also be used for radiator systems. These would however require a larger sized unit to provide heating and is limited to floor area. (Further advice on request).

• AllTechnicalStoresaremadefromandtestedtoB.S.S.standardscopperproduct and carry our normal guarantee.

• ThetermsHeatStore,HeatBanksandThermalStoreallrefertosimilartechnology.

• Allunitsaredesignedtoworkatamax3barincomingcoldwatermainspressure.

• Allunitsarefittedwithafactorysetthermostaticmixingvalve@51°C.

• Thecompanyreservestherighttochangespecificationswithoutnoticeaspartof its policy of continuous improvement.

• AllelectricalinstallationsmustmeetI.E.E.Standards.

GUARANTEE

The Thermal store unit including controls is covered by a 2 year guarantee, excluding damage caused by hard water/limescale or incorrect installation (see terms and conditions). The controls of this unit require a service every 12 months to ensure correct operation. All electrical models are suitable for use with low tariff electricity and come with two immersion heaters fitted as standard.

20

TCC Final.indd 20 1/6/09 15:18:46

Page 21: THE COMPLETE COLLECTION

Linking Tornado or Tempest Together

Stainless Steel Unvented Cylinders

More people are finding that today’s requirements for plentiful hot water can only be met by storage systems. The ultimate provider of high pressure hot water is a Tornado or Tempest unvented cylinder.

All of our domestic unvented cylinders are now formed from 2304 Duplex Stainless Steel. Tornado and Tempest units are finished using a wipe-clean, white coated steel case. Continuing our philosophy of using only the finest materials, the heat loss from the cylinders is minimal, making them extremely economical to run.

We are so confident of the construction that we offer a lifetime guarantee* on our Stainless Steel Tornado and Tempest models and two years on all parts.

As we are continually responding to market requirements we have extended our Stainless Steel range to include cylinders for multiple energy sources including solar energy and horizontal models for use where space is at a premium.

*Contact Telford Copper Cylinders for full guarantee details.

Stainless Steel Unvented

There are occasions when one cylinder is just not sufficient to cope with demands placed upon it. In these circumstances it is possible to link two or more units together. If this sort of installation is required, please call our Technical Assistance line on 01952 257963.

21

TCC Final.indd 21 1/6/09 15:19:20

Page 22: THE COMPLETE COLLECTION

Material Specifications

DUPLEX 2304

There’s Stainless Steel and there’s Stainless Steel! Here at Telford we use superior duplex 2304, unlike some cylinder manufacturers who use the inferior duplex 2101. The properties of any stainless grade are defined not only by its alloy content but also by the way it is produced. Austentic stainless steel 316L is often used in water tanks. This grade offers limited strength properties, so needs to be thick enough to handle the internal pressure.

OUR CYLINDERS

Our Duplex 2304 Tempest and Tornado Stainless Cylinders offer optimised composition alloy elements that have created a stronger and corrosion resistant product that out performs not only other stainless steels but other solutions too.

CYLINDER BODY AND ENDS

Duplex 2304 Stainless Steel. Domed ends are precision manufactured and welded to the body, producing a strong and reliable vessel.

OUTER CASING

White steel with laminated coated finish and corrosion resistant base. Wipe clean surface.

THERMAL INSULATIONCFC and HCFC free rigid polyurethane foam

PRIMARY COIL22mm continuously wound rapid recovery coil, suitable for pumped primary systems only.

IMMERSION HEATERSSupplied with all the models (two on direct). Low noise high grade Incoloy elements and safety cut outs. Titanium immersion heaters are available for an additional cost.

• Easytoinstall• Easytocommission• StepbyStepInstallationGuide• StylishAppearance• LonglifeStainlessSteel• Secondaryreturnstandardon 200 - 300 litre models.

Integrated expansion vessel, (Tornado only)

HCFC + CFC free foam insulation

Wipe clean Mild Steel outer case

High grade Incoloy element

Stainless Steel 3/4” female connections

22

TCC Final.indd 22 1/6/09 15:19:22

Page 23: THE COMPLETE COLLECTION

Performance

Heat-up and re-heat times assume a cold water temperature of 15°C

If using a twin coil variant, where the second coil is linked to a solar energy recovery application, the recovery times listed will improve significantly. Depending on the energy input, the recovery times could be halved.

90 125 150 170 200 250 300

TIME TO RE-HEAT AFTER 70% DRAW-OFF 18 25 26 25 24 25 29

TIME TO RE-HEAT FROM COLD TO 65°C 26 36 37 36 33 35 40

90 125 150 170 200 250 300

TIME TO RE-HEAT AFTER 70% DRAW-OFF 27 37 45 51 63 75 136

TIME TO RE-HEAT FROM COLD TO 65°C 52 72 86 98 108 144 202

Indirect Re-Heat Performance

Direct Re-Heat Performance

Dimensions are for use as guideline only.

Dimensions are for use as guideline only.

Installation

COLD WATER SUPPLY

Telford Stainless unvented cylinders are capable of delivering up to 55 litres of hot water per minute given an adequate supply. The minimum recommended supply is 20 litres per minute at 1.5 bar.

WHAT BOILER SHOULD I USE?

To ensure peak performance and efficiency the cylinder should ideally be connected to an oil-fired or gas condensing boiler. The primary circuit must be pumped and can be open vented or sealed. Energy requirement (BTU/KWH) will vary according to cylinder volume.

LOCATION

Our stainless cylinders can be sited virtually anywhere in the home, but consideration must be given to service clearances and the weight of the cylinder when filled.

CONNECTION DIAMETERS

DOMESTIC SIDE

Cold water inlet and hot water draw-off 3/4” female.

PRIMARY SIDECoil flow and return - 3/4” female

SAFETY VALVES

Temperature and pressure relief - Inlet group 15mm x 15mm pressure relief - 15mm

TUNDISH15mm x 22mm compression

SECONDARY RETURN Standard on cylinders 200L and above.

Stainless Steel Unvented

23

TCC Final.indd 23 1/6/09 15:19:22

Page 24: THE COMPLETE COLLECTION

Technical Specification - Tornado

Capacity (LTR) Height Diameter A B C D E F

90 1220 510 150 180 325 450 - 555

125 1420 510 150 180 350 450 - 760

150 1540 510 150 180 380 480 - 885

170 1780 510 150 180 430 580 - 1030

200 1600 554 150 180 430 580 820 995

250 1920 554 150 180 510 800 980 1155

300 2080 554 150 180 510 800 1100 1305

Indirect

Dimensions are for use as guideline only.

1/2 “ F TPR valve

Secondary return

1 3/4” Immersion heater boss

22mm Cold feed

22mm Hot water draw off

22mm Stat pocket

Secondary return

1 3/4” Immersion heater boss22mm Cold feed

22mm Hot water draw off

24

TCC Final.indd 24 1/6/09 15:19:24

Page 25: THE COMPLETE COLLECTION

Technical Specification - Tornado

Capacity (LTR) Height Diameter A B C D E

90 1220 510 150 180 400 - 555

125 1420 510 150 180 400 - 760

150 1540 510 150 180 400 - 885

170 1780 510 150 180 400 - 1030

200 1600 554 150 180 400 820 995

250 1920 554 150 180 400 980 1155

300 2080 554 150 180 400 1100 1305

Indirect Direct

Stainless Steel Unvented

Dimensions are for use as guideline only.

1/2 “ F TPR valve

Secondary return

1 3/4” Immersion heater boss22mm Cold feed

22mm Hot water draw off

25

TCC Final.indd 25 1/6/09 15:19:25

Page 26: THE COMPLETE COLLECTION

Technical Specification - Tempest

Capacity (LTR) Height Diameter A B C D E F G

90 750 510 170 200 400 495 - 550 750

125 935 510 170 200 400 495 - 750 935

150 1060 510 170 200 400 495 - 880 1060

170 1200 510 170 200 450 600 - 1030 1200

200 1120 554 195 225 475 625 815 930 1120

250 1330 554 195 225 555 845 975 1140 1330

300 1650 554 195 225 555 845 1255 1435 1650

400 1590 660 240 270 640 870 1240 1340 1590

500 1835 660 240 270 640 890 1390 1590 1835

Indirect

Dimensions are for use as guideline only.

1/2 “ F TPR valve

Secondary return

1 3/4” Immersion heater boss

22mm Cold feed

22mm Hot water draw off

22mm Stat pocket

Secondary return

1 3/4” Immersion heater boss

22mm Cold feed

22mm Hot water draw off

26

TCC Final.indd 26 1/6/09 15:19:26

Page 27: THE COMPLETE COLLECTION

Technical Specification - Tempest

Capacity (LTR) Height Diameter A B C D E F

90 750 510 170 200 410 - 550 750

125 935 510 170 200 410 - 750 935

150 1060 510 170 200 620 - 880 1060

170 1200 510 170 200 620 - 1030 1200

200 1120 554 195 225 645 815 930 1120

250 1330 554 195 225 645 975 1140 1330

300 1650 554 195 225 645 1255 1435 1650

400 1590 660 240 270 690 1240 1340 1500

500 1835 660 240 270 690 1390 1590 1835

Indirect Direct

Dimensions are for use as guideline only.

1/2 “ F TPR valve

Secondary return

1 3/4” Immersion heater boss

22mm Cold feed

22mm Hot water draw off

27

Stainless Steel Unvented

TCC Final.indd 27 1/6/09 15:19:27

Page 28: THE COMPLETE COLLECTION

Variants

Tornado Easy-Fit

Twin Coil

Stainless Unvented Horizontal

Since perfecting the product, several developers have approached Telford Cylinders and asked if we would pre-plumb our successful Tornado Cylinder.

Using market leading components we are able to fabricate the Tornado to any configuration that may be required, ie S & Y-Plan. This saves valuable time on site for both the plumbing and electrical contractor and ensures a uniform installation in each plot.

Environmental issues are currently at the forefront of peoples thoughts. Developers are now looking at solar energy as a complement to gas or oil powered boilers. Solar not only benefits the environment by reducing the amount of natural resources we consume, but also makes the heating of a building far more efficient and helps to lower utility bills. Our twin coil stainless cylinder is available in all sizes throughout the Tempest range and includes all necessary safety controls.

CAP (LTR)

125

150

170

200

250

300

CAP (LTR)

170

200

250

300

500

Capacity (LTR)

Length Diameter Height

125 900 500 600

150 1050 500 600

170 1200 500 600

200 1100 550 650

250 1200 550 650

300 1400 550 650

Dimensions are for use as guideline only.(foamed as standard)

28

TCC Final.indd 28 1/6/09 15:19:35

Page 29: THE COMPLETE COLLECTION

How Solar Energy Heats Your Home

Alternative Energy

Although the UK is not renowned for hours of sunshine, due to advanced technology householders can still enjoy high energy levels from our Tempest Solar System.

Solar radiation is absorbed by the collector’s evacuated tubes and converted into heat. Pipes conduct the heat to a header through which a conductive liquid (water or water/glycol) is pumped. The liquid is circulated through a pump station to the coil in the Tempest Solar Cylinder where the liquid gives up its energy to the water in the cylinder in the form of heat.

In every part of the UK a Tempest Solar system will provide free energy to heat domestic hot water reducing household energy bills.

Alternative Energy

Tornado Easy-Fit

Twin Coil

Stainless Unvented Horizontal

Tempest Stainless Steel Solar Cylinder

The heart of the system in which water for domestic use is heated with the energy collected at the solar panel. The cylinder also has a boiler coil and immersion heater for back up.

Evacuated Tube Solar Panel

Absorbs and transfers solar energy to hot water cylinder via the pump station.

Pump Station

Monitors and circulates heated liquid from the solar panel to the Tempest Stainless Stell Solar cylinder coil to heat domestic hot water.

29

TCC Final.indd 29 1/6/09 15:19:39

Page 30: THE COMPLETE COLLECTION

Tempest Solar Cylinders

Tempest Direct Solar Cylinder Dimensions

Our Tempest Solar cylinder is produced from recyclable Duplex 2304 stainless steel; as much as 90% of post service life steel is converted into prime stainless products.

Until recently reserved for use in chemical and oil refinery processes, the corrosion resistant properties of Duplex are greater than those afforded by other grades of stainless steel used into days water tanks.

We are so confident of the construction that we have given all of our Tempest Stainless Steel Solar cylinder bodies a lifetime warranty1

So, whichever way you look at it Duplex 2304 makes the Tempest Solar far superior.

1 Contact our Sales Office for guarantee details.

Dimensions are for use as guideline only.

T&P Relief Valve

Hot Water Draw Off - I

Solar Sensor - H

Secondary Return* - G

Immersion Heater 1 ¾” - F

Immersion Heater 1 ¾” - E

Solar Boiler Flow - DAquastat Pocket - C

Solar Sensor - BCold Water

Solar/Boiler Return - A

Cap (ltr)

170 200 250 300 400 500

Height 1780 1600 1920 2080 1590 1835

Dia 510 554 554 554 680 680

A 175 200 195 200 235 235

B 165 245 245 250 285 285

C 395 395 395 400 435 435

D 505 510 505 510 620 620

E 535 615 575 575 715 715

F 395 395 395 650 1085 1085

G 865 785 890 895 1240 1390

H 1915 900 1025 1030 1340 1590

I 1780 1600 1920 2080 1590 1835

30

* - 200L and above

TCC Final.indd 30 1/6/09 15:19:40

Page 31: THE COMPLETE COLLECTION

Tempest Indirect Solar Cylinder Dimensions

• Easytoinstall• Pressuretestedto15bar• Reliefvalvesafetycontrol• 3Barworkingpressure• Flowrateupto55ltrs/min• Indirectanddirectversions• Stylishappearance• Lifetimeguarantee

Tempest Solar Cylinders

Cap (ltr) 170 200 250 300 400 500

Height 1200 1120 1330 1650 1590 1835

Dia 510 554 554 554 660 660

A 175 190 190 190 235 235

B 175 245 245 245 285 285

C 395 390 390 390 435 435

D 500 500 500 500 620 620

E 535 545 575 570 715 715

F 585 585 640 640 820 820

G 865 780 890 885 1120 1120

H 1015 890 1025 1020 1240 1260

I n/a 890 1025 1250 1240 1240

J 1040 930 1140 1430 1340 1590

Dimensions are for use as guideline only.

Hot Water Draw Off - I

Alternative Energy

T&P Relief ValveSolar Stat - H

Secondary Return* - G

Boiler Stat

Immersion Heater 1 ¾” - E

Aux Stat - C

Mains Inlet - A

Solar Stat - B

31

* - 200L and above

TCC Final.indd 31 1/6/09 15:19:42

Page 32: THE COMPLETE COLLECTION

Tristor Renewable

The position of the tappings will vary depending on the size and type of store and heat source(s) to be used in addition to solar.

Dimensions are quoted in mm for guidance only.

Telford Specialise in producing bespoke cylinders to meet any requirements for more info please call our technical department.

Hot water at mains pressure without a pressurised cylinder!

Thermal stores do not require G3 Building Control Notification and no special qualifications are required to install the cylinder.

Our popular Tristor is now available in stainless steel, suitable for use with Solar, Underfloor Heating and a conventional Boiler with an immersion heater for back up.

The Tristor renewable has been developed to utilise the benefits of solar energy. This sealed system is suitable where the provision for a feed and expansion tank is impractical.

At the heart of the unit is the same Tristor TM technology for proven hot water performance.

• Uniquedesign

• Highflowrates

• Thermostaticallyblendedhotwaterat51°c

• Highefficiency-lowheatloss

• Easytoinstallandcommission

• Stylishappearance

Capacity (ltr) Height Diameter

200 1750 510

280 2000 555

28mm Connection

1” Boiler Flow

Domestic Hot Out

Solar Sensor Blind Pocket

Boiler Stat Blind Pocket

Under Floor Flow 1”

Boiler Return 2

3Kw Immersion Heater

22mm Solar Flow

28mm Connection

Domestic Cold Mains Inlet

Solar Return

1” Return

Under Floor Return

Solar Sensor Blind Pocket

Dimensions are for use as guideline only.

32

TCC Final.indd 32 1/6/09 15:19:43

Page 33: THE COMPLETE COLLECTION

Vented Copper and Stainless Solar Cylinders

Alternative Energy

Copper Vented Solar Cylinders

Capacity Height Diameter

140 1050 450

170 1200 450

200 1500 450

250 1800 450

Stainless Vented Solar Cylinders Cased

Capacity Height Diameter

170 1200 510

200 1120 554

250 1330 554

300 1650 554

400 1590 660

500 1835 660

The minimum volume of a stainless steel vented solar cylinders is 170 litre. Our Stainless steel range has a lifetime guarantee on the cylinder body.

NB. The minimum dimensions of a copper solar cylinder is 1200mm x 400mm.

The development of solar and alternative energy sources means that we can now offer many of the vented copper and stainless cylinders from our comprehensive range for use in a solar or alternative energy system1. Now users have the opportunity to access an efficient solar or alternative energy source solution where a mains pressure cylinder or thermal store is not appropriate.

Manufactured to BS1566:2002 and compliant with Part L of the Building Regulations; direct and indirect versions are available.

• Straightforwardinstallation• Noservicingrequirement• Fullyinsulated• Complieswithcurrentregulations• Widerangeofsizes• Bespokecylinderservice2

• Stainlesssteelcylinderscased or foam lagged• Lifetimeguarantee3

1 Minimum size 1200 x 450 copper or 170 litre stainless2 Subject to size and performance conditions.3 On Stainless steel bodies only.

Dimensions are for use as guideline only.

Dimensions are for use as guideline only.

Stainless Vented Solar Cylinders Foamed

Capacity Height Diameter

170 1200 450

200 1500 450

250 1200 500

300 1800 500

Dimensions are for use as guideline only.

33

TCC Final.indd 33 1/6/09 15:19:53

Page 34: THE COMPLETE COLLECTION

The Telford Complete Solar System

The Complete Solar System Package

1X Tempest Solar Unvented Cylinder (with G3 Kit)

1X Resol Pump Station

1X 18L Expansion Vessel

10Mtr Stainless Flow and Return Flexi Pipe

Evacuated tube/flat Solar Panel with Bracket Set (quantity depends on size of cylinder)

Working in conjunction with market leaders in the solar energy field Telford can provide the perfect solar package.

An Evacuated Tube Panel converts the solar energy into useable heat for transfer into the cylinder and is far superior to other panel designs.

The Pump Station circulates the liquid heated in the panel to the cylinder where the energy is transferred to the domestic hot water via the high efficiency solar coil.

The heart of the system is the Telford Solar Tempest Stainless Steel mains pressure cylinder which with its conventional boiler coil and immersion heater back up provides hot water for domestic use.• Wholepackagefromonesource• Pumpstation

• Evacuatedtubesolarpanel(s)SolarKeyMark approved• TempestDuplex2304StainlessSteelcylinder(lifetime guarantee)1

• Allcontrols,sensorsandsafetydevicesincluded• Complieswithcurrentregulations• Easytoinstall

1 On Tempest body only

34

TCC Final.indd 34 1/6/09 15:20:00

Page 35: THE COMPLETE COLLECTION

Tristor HP

Solar Panel Guidelines

Alternative Energy

South/South West/South East Facing at 45°C

170Ltr Un-vented cylinder 2x Suntech flat panel 2Mtr - 1Mtr (ST-FP-STD)

200Ltr Un-vented cylinder 2x Suntech flat panel 2Mtr - 1Mtr (ST-FP-STD)

250Ltr Un-vented cylinder 3x Suntech flat panel 2Mtr - 1Mtr (ST-FP-STD)

300Ltr Un-vented cylinder 3x Suntech flat panel 2Mtr - 1Mtr (ST-FP-STD)

South Facing at 45°C South West Facing at 45°C South East Facing at 45°C

170Ltr Un-vented cylinder 30 Tubes 30 Tubes 22+10 Tubes

200Ltr Un-vented cylinder 22+10 Tubes 30+10 Tubes 30+10 Tubes

250Ltr Un-vented cylinder 30+10 Tubes 22+22 Tubes 30+22 Tubes

300Ltr Un-vented cylinder 22+22 Tubes 30+22 Tubes 30+30 Tubes

Our popular Tristor thermal store is now available in a heat pump version, with conventional boiler or immersion heater for back up. For use with any standard heat pump.

These charts are to be used as guidelines only.

Evacuated Tube Panel

Flat Plate Collectors

expansion vessel

source

Tristor HP (THP)

THP 150 200

Height 1820 1820

Overall Dia 510 554

35

TCC Final.indd 35 1/6/09 15:20:01

Page 36: THE COMPLETE COLLECTION

Eco Air Heating System

The eco air heating system works by extracting ambient heat from the air around us and converting it through highly effi cient heat exchangers into useable household energy that can be used to heat domestic water, radiators and underfl oor heating systems. The simple to install system comprises an external heat exchanger which can be discreetly fi tted to the side of the building and an unvented system which is located internally.

Our system is so effi cient that it can draw useable energy from air as cool as -20°C and can run without a backup heating system installed, providing water temperatures of 60-65°C all year round.

The advantages of this means that you have a signifi cant reduction in carbon emmissions, which coupled with roof mounted P. V. panels achieves almost zero running costs.

THE ECO AIR HEATING SYSTEM

No conventional boiler or additional • electric heaters required Save up to 2/3 of your energy running costs•Signifi cant CO• ² reductionRenewable energy•Payback in approximately 5 years•Up to COP 5 rating•Energy conversion achievable at lower than -5°C•Easily Installed, maintained and operated•Can be used as a combined heat and power system when coupled with PV panels•Touch screen heat exchanger control with individual zone control for heating and hot water.•

Transfer Box

External air containing recoverable ambient heat

Generated power sold back to the National Grid resulting in Net £0 charge to the building

ENERGY USED TO RE-HEAT A 250L CYLINDER FROM 20°C TO 60°C

Ambient Temperature °CGraph based on internal testing figures

Pow

er k

W

5-9 10-14 15-19 20-25

12

10

8

6

4

2

0 EC

O A

IR

ELE

CTR

IC H

EA

T

EC

O A

IR

ELE

CTR

IC H

EA

T

EC

O A

IR

ELE

CTR

IC H

EA

T

EC

O A

IR

ELE

CTR

IC H

EA

T

10.5

4.43.9 3.6 3.5

10.5 10.5 10.5

Roof Mounted PV Panels 3kW output

Eco Air Heating SystemEco Air Heating System

36

TCC Final.indd 36 1/6/09 15:20:03

Page 37: THE COMPLETE COLLECTION

Eco Air Heating System

The eco air heating system is currently the most efficient system available, achieving up to cop 5 energy efficiency at 30°C ambient temperature; for every one unit of energy you put in you get five back out. This is unique in the global energy making market.

These features make the eco air heating system ideal for the following applications; domestic dwellings, social housing, flats, hotels, leisure centres, public buildings.

Height 1595mm

Width 845mm

Depth 595mm

Heat Output 9kW

Water Connector 22mm

COP up to COP 5.0

Power Supply 230V / 1ph / 50Hz

Split Second Starting Current 20 Amps

Refrigerant R407C

Min. Ambient Temperture -20°C

Max. Ambient Temperture 60°C

Insulation 25mm Armerflex

250ltr Cylinder 300ltr Cylinder Dual 500ltr

Height 1795mm 2000mm 1900 and 690mm

Width 560mm 670mm 670 and 560mm

Outer Case White Steel White Steel White Steel

Immersion Heater 3kW 1ph 3kW 1ph 3kW 1ph

Insulation Foam Injected Foam Injected Foam Injected

G3 Building Regulation Kit Supplied Supplied Supplied

Eco Air Heater

Alternative Energy

37

TCC Final.indd 37 1/6/09 15:20:08

Page 38: THE COMPLETE COLLECTION

T & P RELIEF VALVE 3/4 7 BAR STAINLESS STEEL

CODE - ALT1/2TP 7BAR

STAINLESS IMMERSION HEATER 14” 1 3/4

CODE - SHELINK14SSUNV

THERMAL STORE IMMERSION HEATER 2 1/4

CODE - SHELINK14TRI

12L EXPANSION VESSEL

CODE - 12EXP

19L EXPANSION VESSEL

CODE - 19EXP

24L EXPANSION VESSEL

CODE - 24EXP

EXPANSION VESSEL BRACKET

CODE - EXBRACK

Parts

38

TCC Final.indd 38 1/6/09 15:20:26

Page 39: THE COMPLETE COLLECTION

Alternative Energy

TUNDISH 15MM - 22MM

CODE - 15TUND

TUNDISH 22MM - 28MM

CODE - 28TUNDISH

BLEND VALVE

CODE - INTABLEND

2 PORT HONEYWELL VALVE

CODE - HON222ONEVALV

DUAL AQUASTAT

CODE - ALTTGSTAT

SINGLE AQUASTAT

CODE - AQUA2002

INLET PACK 3 BAR

CODE - ALTINLET223BAR

Parts

39

TCC Final.indd 39 1/6/09 15:20:46

Page 40: THE COMPLETE COLLECTION

Telford Copper Cylinders LimitedFurrows Business ParkHaybridge RoadTelford TF1 2FE

Get in touch today1. Telephone: 01952 2579612. Fax: 01952 253452www.telford-group.com

Printed Date - 2009

TO H

TCC Final.indd 40 1/6/09 15:20:48