DESCRIPTION
Introducing America’s First UV Cured Fiberglass CIPP. The Best Solution for CIPP American Made, American Support. Strength. Test Results 4MM 8” StreamlinerUV ™ Liner Flexural strength: 52,000 PSI 50 year flexural strength: 33,840 PSI (65% retention) Flexural modulus: 1,700,000 PSI - PowerPoint PPT Presentation
Citation preview
The Best Solution for CIPP
American Made, American Support
Introducing America’s FirstUV Cured Fiberglass CIPP
Test Results4MM 8” StreamlinerUV™ LinerFlexural strength: 52,000 PSI50 year flexural strength: 33,840 PSI (65% retention)
Flexural modulus: 1,700,000 PSI50 year flexural modulus: 1,160,240 PSI (68% retention)
3MM 8” StreamlinerUV™ LinerFlexural strength: 47,000 PSIFlexural modulus: 1,350,000 PSI
STRENGTH
PERFORMANCE
Water Tight: 100% leak proof*No Shrinkage: 0.0% loss*
Thin Wall: From 3mmCured: Ultra Violet Light
Curing Speed: 7.5ft per minute (8” )Laterals: No seals or grouting required
Flow: Hazen-Williams C=150
*2009 IKT Liner Report, (Institute for Underground Infrastructure)
LINER CONSTRUCTION
Polyester outer containment and protection foil.
Chemical and temperature resistant 7 layer polyethylene/polyamine inner containment foil.
Multiple layers of high quality E-CR fiberglass. The fiberglass layers are saturated with polyester or vinyl ester resins during manufacturing.
Translucent UV resistant outer foil.
LINER CONSTRUCTION
Clear inner foil is removed.
Outer foil remains in the pipe after curing.
Proprietary resin “jelling” maintains consistent wall thickness during storage, shipping and installation.
Line is bypassed Upstream manhole is plugged
LINER INSTALLATION
Line is cleaned and pre-videoed Rope pulled in during pre-video
Pre-liner pulled through the pipe with rope inserted from pre-video
LINER INSTALLATION
Second rope is pulled through pipe with pre-liner.
Liner is delivered to the job site Liner is pulled in place by a winch
LINER INSTALLATION
Safety sleeves are inserted on liner End caps are installed on each end of
the liner
LINER INSTALLATION Liner is inflated and calibrated at 8psi Light Train is inserted and pressure is
restored
Light Train Camera is activated Light Train is manually pulled and
uncured liner is video inspected
LINER INSTALLATION Any installation issues are
resolved and video is archived.
Light Train UV lamps are activated Light Train is pulled via computer
control through the liner.
LINER CURING Speed, temperature and pressure
are monitored throughout the curing process.
LINER CURING
COMPARISONCURING
UVFG
FELT
ULTRA VIOLET LIGHT STEAM OR HOT WATER
Crew S
ize3
to 5
Cure
Tim
e
7ft p
er m
in.
Cool T
ime
0
Runs
per D
ay
2 to
3
Job
Site T
ime
2.5
Hours
Crew
Size
5 to 6
Cure Tim
e
2.5+ Hours
Cool Tim
e
45 to 60 min
Runs per D
ay
1 to 2Job S
ite Time
5 Hours
COMPARISONINSTALLATION
UVFG
FELT
COMPARISONSTRENGTH
•52,000 PSIFlexural Strength
•1.7M PSIFlexural Modulus
•E-CR GlassMaterial
•9,300 PSIFlexural Strength
•448,000 PSIFlexural Modulus
•Needled FeltMaterial
UVFG
FELT
UVFG
FELT
COMPARISONLONGEVITY
Year 1 Year 25 Year 500
200,000400,000600,000800,000
1,000,0001,200,0001,400,0001,600,0001,800,000
1,700,000
1,400,000
1,160,240
448,000350,000
260,000
UVFG Flex Modulus*Felt Flex Modulus**
* D2990 test results StreamLiner UV* *Insituform
*2009 IKT Liner Report, (Institute for Underground Infrastructure)
100% water tight* 63% water tight *
COMPARISONWATER TIGHTNESS
UVFG
FELT
COMPARISONSHRINKAGE
UVFG
FELT
0.0% ≤5%
UVFG
FELT
COMPARISONINNER DIAMETER
8” 3MM Liner0% Shrinkage
Loss of I.D.
5.8%
8” 6MM Liner3% Shrinkage
Loss of I.D.
15.8%
BID RESULTS
UVFG Felt Felt $-
$500,000.00
$1,000,000.00
$1,500,000.00
$2,000,000.00 $897,895.0
0
$1,217,528
.00
$1,547,106
.00
Project 2842755 -- Sanitary Sewer Rehabilita-tion Homer, AK
BID RESULTS
UVFG Felt Felt $-
$2,000,000.00 $4,000,000.00 $6,000,000.00 $8,000,000.00
$10,000,000.00 $4,580,000
.00
$6,990,000
.00
$8,640,000
.00
Brandywine Hundred 2009 CIPPL Sewer Rehabilitation New Castle, DE
BID RESULTS
UVFG Felt Felt $-
$500,000.00 $1,000,000.00 $1,500,000.00 $2,000,000.00 $2,500,000.00
$1,596,656
.00
$1,655,348
.00
$2,072,066
.00
Sewer Pipeline Rehabilitation Phase J1BCity of San Diego
Flexural Mod 448K PSIFlexural Strength of 9300 PSINo pre-cure videosThicker wall and reduced flow
Liner shown to shrinkLiner shown to leakMust seal lateral connectionsMust deal with odor and styrene
and you were being presented with…
Would you even consider felt technology?
What if today's standards were…No ShrinkageNo leakingNo Lateral Seals neededNo odor or curing by-products
Flexural Mod of 1.7M PSIFlexural Strength 52K PSIMultiple curing videosThinner liner and greater flow
NEXT STEPS
Review the Streamliner UV specification doc
Recommend UV fiberglass as an approved material