24
Mike Seifert, P.Geol. Canadian Discovery Ltd. The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations.

The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Embed Size (px)

Citation preview

Page 1: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Mike Seifert, P.Geol. Canadian Discovery Ltd.

The Application of Digital Completions and Fracture Data for the Validation of

Microseismic Observations.

Page 2: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Well Completions & Frac Database

1) Why we built it 2) How we built it 3) What is in the database 4) Validation of Microseismic 5) Observations & Conclusions

Page 3: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Used over 18,000 ISIP and leak-off test data points to derive: • MPS • Stress Gradient Maps • Effective Stress Ratio

Maps • Passive Boundary • Estimated Over Burden

Removal

Why we built it

Stress Analysis – Central Alberta Study: Rakhit Petroleum Consulting, BJ Services

Page 4: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Well Completions & Frac Database

Page 5: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

How we built it

Source Documents from respective Regulatory Agencies: • Daily Completion

Reports • Drilling Tours

Page 6: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

How we built it

Page 7: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

How we built it

KEY DATA ANALYSIS

Page 8: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

How we built it

DETAILED ANALYSIS

Page 9: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

How we built it

DETAILED ANALYSIS

Page 10: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

How we built it

DETAILED ANALYSIS

Page 11: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Frac Analysis Data

Stage - Stage Number

Stage - Operation

Stage - Stage Top Depth

(mKB)

Stage - Stage Bottom Depth

(mKB)

Stage length Stage - Break Down Pressure

(MPa)

Stage - Proppant

Placed Total (t)

Stage - ISIP (MPa)

Stage - Total Pumped Fluid

(m3)

1.1 Mini(data) 4692.6 4693.9 1.3 56.68 27.5 1.46 1.2 Frac 4692.6 4693.9 1.3 200 28 1650 2.1 Frac 4550.0 4601.5 51.5 42.6 200 27.9 1785 3.1 Frac 4461.5 4510.0 48.5 45.2 180 55.1 2608 4.1 Frac 4371.5 4420.0 48.5 46.2 200 30.2 1942 5.1 Frac 4280.0 4331.5 51.5 42.4 200 31.3 2255 6.1 Frac 4190.0 4241.5 51.5 47.1 200 31.5 1748 7.1 Frac 4060.0 4131.5 71.5 55 200 30.9 1808 8.1 Frac 3720.0 3811.5 91.5 32.6 180 29.6 1698 9.1 Frac 3610.0 3681.5 71.5 39.2 240 29.9 2100

HORN RIVER MICROSEISMIC DATA: ConocoPhillips Canada

Page 12: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Frac Analysis Data

Stage - Stage Number

Stage - Operation

Stage - Stage Top Depth

(mKB)

Stage - Stage Bottom Depth

(mKB)

Stage length Stage - Break Down Pressure

(MPa)

Stage - Proppant

Placed Total (t)

Stage - ISIP (MPa)

Stage - Total Pumped Fluid

(m3)

1.1 Mini(data) 4692.6 4693.9 1.3 56.68 27.5 1.46 1.2 Frac 4692.6 4693.9 1.3 200 28 1650 2.1 Frac 4550.0 4601.5 51.5 42.6 200 27.9 1785 3.1 Frac 4461.5 4510.0 48.5 45.2 180 55.1 2608 4.1 Frac 4371.5 4420.0 48.5 46.2 200 30.2 1942 5.1 Frac 4280.0 4331.5 51.5 42.4 200 31.3 2255 6.1 Frac 4190.0 4241.5 51.5 47.1 200 31.5 1748 7.1 Frac 4060.0 4131.5 71.5 55 200 30.9 1808 8.1 Frac 3720.0 3811.5 91.5 32.6 180 29.6 1698 9.1 Frac 3610.0 3681.5 71.5 39.2 240 29.9 2100

HORN RIVER MICROSEISMIC DATA: ConocoPhillips Canada

Page 13: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Validating Microseismic

HORN RIVER MICROSEISMIC DATA: ConocoPhillips Canada

Observation Well

Page 14: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Validating Microseismic

Hypo-Centre Plot Plan View

STAGE 1.1 Mini Frac Break Down: 56.7 Mpa ISIP: 27.5 Mpa

Page 15: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Validating Microseismic

Hypo-Centre Plot Transverse View

STAGE 1.1 Mini Frac Break Down: 56.7 Mpa ISIP: 27.5 Mpa

Page 16: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Validating Microseismic

Hypo-Centre Plot Plan View

STAGE 2 - 6 Frac Break Down: 44.7 Mpa ISIP: 35.2 Mpa Stage Length: 50.3 m Proppant: 196 t Fluid: 2,068 m3

Page 17: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Validating Microseismic

Hypo-Centre Plot Transverse View

STAGE 2 - 6 Frac Break Down: 44.7 Mpa ISIP: 35.2 Mpa Stage Length: 50.3 m Proppant: 196 t Fluid: 2,068 m3

Page 18: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Validating Microseismic

Hypo-Centre Plot Plan View

OBS Well No Frac Length: ~250 m

Page 19: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Validating Microseismic

OBS Well No Frac Length: ~250 m

Hypo-Centre Plot Transverse View

Page 20: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Validating Microseismic

Hypo-Centre Plot Plan View

STAGE 9 Frac Break Down: 39.2 Mpa ISIP: 29.9 Mpa Stage Length: 50.3 m Proppant: 240 t Fluid: 2,100 m3

Page 21: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Validating Microseismic

Hypo-Centre Plot Transverse View

STAGE 9 Frac Break Down: 39.2 Mpa ISIP: 29.9 Mpa Stage Length: 50.3 m Proppant: 240 t Fluid: 2,100 m3

Page 22: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Observations & Conclusions

We do see a correlation of Frac Data to Microseismic Hypo-centre Plots Where there are inconsistencies, other information may be required to better understand differences Require better information on Microseismic data to identify which completions have been monitored

Page 23: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Acknowledgements

Amy Fox Aliyyah Mohamed

Andy Vogan Larry Matthews

Microseismic User Group

Page 24: The Application of Digital Completions and Fracture Data ... · The Application of Digital Completions and Fracture Data for the Validation of Microseismic Observations. ... STAGE

Well, it's sugar for sugar. And salt for salt, If you go down in the flood, It's gonna be your own fault. Bob Dylan, Down in the Flood