Testing Protocols for Performance

Evaluation of Masonry Panels

Dr. Vaibhav Singhal

Department of Civil and Environmental Engineering

Indian Institute of Technology Patna

22nd July 2017

Workshop on

Performance Evaluation of Housing Units

Page 2: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

2

Performance Evaluation of Masonry

Material Characterization

Laboratory Tests

Field Tests

Masonry Wall

Laboratory Tests

Testing Protocols

Page 3: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Characterization of Brick Units

3

Material Properties

• Field Tests

• Water Absorption (WA)

• Initial Rate of Absorption (IRA)

Mortar bond strength

Important to assist in mortar selection and

material handling

• Compressive strength (fb)

• Tensile strength

Flat Position

On edge

Page 4: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Characterization of Brick Units…

4

Water Absorption and Initial Rate of Absorption

Gives information about quality of bricks

IRA: Suction of water from mortar due to capillary action in bricks (per minute, per unit area, brick immersed in about 3 mm deep water) – ASTM C67

IRA test is not mandatory as per IS:3495 (1992)!!!

fbWA IRA

Page 5: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Characterization of Brick Units…

5

Compressive Strength

IS 3495 – Part 1: Solid, Perforated Clay Bricks, Fly-ash Bricks

IS 2185 – Part 1: Hollow and Solid Concrete Blocks

IS 6441 – Part 5: Autoclaved Cellular Concrete Products

ASTM C67-13: Testing Brick and Structural Clay Tile

Source: Basha and Kaushik (2015)

Page 6: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Characterization of Brick Units…

6

Tensile Strength

Source: Singhal and Rai (2014)

Page 7: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Characterization of Masonry

In any masonry structure, during a seismic event its various

elements/components are under the influence of a variety of

actions.

For instance, a masonry wall could at any point be under a

vertical compressive load, in-plane and/or out-of-plane lateral

loads, etc.

Important to characterize the fundamental behaviour

Compression

Tension

Flexure

Shear

7

Page 8: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Characterization of Masonry in Compression

IS 1905 – recommend to determine compressive strength of

masonry by prism test.

Masonry prisms should be atleast 40 cm high and shall have a

height to thickness ratio (h/t) of atleast 2 and not more than 5.

Prisms shall be tested after 28 days

8

5-brick stack bonded prism

Page 9: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

ASTM C1314

Used for determining the compressive strength of prisms obtained from field-removed masonry specimens.

9

Construction of different types of masonry prisms

Characterization of Masonry in Compression

Page 10: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Characterization of Masonry in Tension

10

Tension Bond Strength: required for masonry wallssubjected to wind, eccentric gravity loads, and so on.

Indian code remains silent.

Tests include the bond wrench test, direct tension test, andcrossed couplet test, and all the test procedures has their owndrawbacks and problems (Khalaf 2005).

A new Z-shaped specimen proposed by Khalaf (2005).

Source: Singhal and Rai (2014)

Page 11: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Characterization of Masonry in Flexure

11

Flexure Bond Strength

Flexural bond strength is crucial in normal as well as

parallel directions to the bed-joint.

Current masonry design codes [MSJC (2011)] duly consider

the flexural tensile strength in the design of masonry in

both directions.

BS EN 1052-2 describes the test method.

Source: Singhal and Rai (2014)

Page 12: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Contd.-Flexure test

12

Plane of failure parallel to bed

joints

Plane of failure perpendicular to

bed joints

Page 13: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

13

Characterization of Masonry in Shear

BS EN 1052-2 describes the test method

Shear Strength and Friction Factor

Without pre-compression –initial shear strength

With pre-compression at 0.2, 0.4, 0.6 and 0.8 MPa – friction factor

Test setup

Page 14: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

To determine the level of stresses in the masonry

Various mechanical parameter

Elastic Modulus

Compressive Strength

Joint Shear Strength

14

In-Situ Strength Measurement

Page 15: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

ASTM C 1197

Deformability properties in compression and compressive

strength (double flat-jack test)

Shear strength parameters (shear flat jack test)

15

Flat-Jack Test

Source: NCREP

Page 16: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

ASTM C 1197

Deformability properties in compression and compressive

strength (double flat-jack test)

16

Flat-Jack Test

Source: expin.it

Page 17: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

ASTM C 1197

Shear strength parameters (shear flat jack test)

17

Flat-Jack Test

Source: Simoes et al. (2012)

Page 18: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

ASTM C1531

Used to determine the in-situ the shear strength of the masonry.

18

Shove Test

Source: giancarlomaselli.it

Page 19: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

ASTM C1531

Method A : with Flat jacks Controlling Normal Compressive Stress

Method B : without Flat jacks Controlling Normal Compressive Stress

19

Shove Test

Page 20: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Diagonal Compression Test

ASTM E519/E519M

Determine the shear strength of masonry panel by loading them in compression along one diagonal

Size of panel > 1.2 m by 1.2 m [4 by 4 ft.]

20

Test on Masonry Wall Panels

Page 21: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

ASTM C1717

Determine the strength and load-deflection characteristics of masonry wall elements.

Simplest loading protocol is monotonic loading to failure.

Complex loading protocol is cycles of loading (possibly reversed) to monotonically increasing maximum amplitudes.

21

Test on Masonry Wall Panels…

Page 22: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

22

Test Setup for Axial Compressive Loading

User can measure axial load, axial deformation, out-of-plane deflection using a reference line or a fixed line.

Axial Compression Test

Page 23: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

23

Apparatus for Uniformly Distributed Transverse Load (Bag Method)

Apply transverse load to the specimen by increasing the air pressure in the bag.

Measure the pressure by means of a manometer.

Out-of-plane Load Test

Page 24: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

24

Out-of-plane Load Test…

Source: Myers (2008)

Page 25: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Apparatus

Steel Channel with Roller Supports

Loading Assembly

Hydraulic Ram.

Load-measurement Devices.

Out-of-plane Deflection Gauges

Axes of the rollers shall be parallel to the faces of the specimen.

Apply the loads horizontally by a hydraulic ram

Measure load using a load cell between the hydraulic ram and the specimen, or using two load cells, one between the specimen and each end of the loading beam.

25

Out-of-plane Load Test…

Page 26: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

26

Test Setup for Concentrated Load Test

Concentrated Load Test

Page 27: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

In-Plane Shear Load

Apparatus

Base

Loading Beam

Hydraulic Rams

Load-measurement Devices

Out-of-plane Restraint

In-plane Deflection Gauges

Subject the specimen to the desired protocol of shear and axial loading.

27

Contd.-Tests of Masonry Wall Panels

Page 28: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

28

Test Setup for In-plane Load

In-plane Load Test

Setup

Base

Loading Beam

Hydraulic Rams

Load-measurement Devices

Out-of-plane Restraint

In-plane Deflection Gauges

Page 29: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

29

In-plane Load Test…

Source: Billington et al. (2009)

Page 30: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

ASTM E2126

Stiffness and strength parameters

Deformation/Ductility capacity

Hysteretic response

Energy Dissipation capacity

Degradation and Recovery parameter

30

Cyclic Load Test

Page 31: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Elastic shear stiffness, shear strength and ductility of specimens are determined by subjecting a specimen to full reversal cyclic racking shear loads.

31

Observed Hysteresis Curve and Envelope Curves for Test Method A

Observed Hysteresis Curve and Envelope Curves for Test Method B

Cyclic Load Test…

Page 32: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

32

Test Setup for Shear Wall Specimen

Cyclic Load Test…

Page 33: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Racking load is applied horizontally along the plane of the

specimen using a double-acting hydraulic actuator.

A minimum of two specimens is required for the testing.

Method A (Sequential-Phased Displacement Procedure)

Method B (ISO 16670 Protocol)

Method C (CUREE Basic Loading Protocol)

33

Contd.- Cyclic Load Test for Masonry Wall

Page 34: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Method A: Sequential Phased Displacement (SPD)

Loading Protocol

34

Cyclic Displacement Schedule (Test Method A)

Single Phase of Pattern 2 (Test Method A)

Displacement-controlled loading procedure that involves displacement cycles grouped in phases at incrementally increasing displacement levels.

The cycles shall form either a sinusoidal wave or a triangular wave.

Page 35: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

SPD loading consists of two displacement patterns

First pattern consists of three phases, each containing three fully-reversing cycles of equal amplitude, at displacements representing 25 %, 50 %, and 75 % of anticipated FME.

In second pattern, each phase is associated with a respective displacement level and contains one initial cycle, three decay cycles, and a number of stabilization cycles.

35

Performance Parameters of

Specimen

Contd.- Method A

Page 36: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Test Method B (ISO 16670 Protocol):

Procedure involves displacement cycles grouped in phases at incrementally increasing displacement levels.

consists of two displacement patterns

First pattern consists of five single fully reversed cycles at displacements of 1.25 %, 2.5 %, 5 %, 7.5 %, and 10 % of the ultimate displacement Δm.

Second pattern consists of three fully reversed cycles of equal amplitude, at displacements of 20%, 40 , 60%, 80%, 100%, and 120% of the ultimate displacement Δ m.

36

Cyclic Displacement Schedule (Test

Method B)

Page 37: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Test Method C (CUREE Basic Loading Protocol):

• Procedure involves displacement cycles grouped in phases at incrementally increasing displacement levels.

• The value of Δ shall not exceed 0.025 times the wall height.

37

Cyclic Displacement Pattern (Test Method C)

Amplitude of Primary Cycles

Page 38: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

38

Choice of a testing program and

associated loading history depends on

purpose of the experiment,

type of test specimen and

type of anticipated failure mode

Masonry walls tested independently in

in-plane and out-of-plane direction

using the various standard loading

protocol developed for planar

structures and sub-assemblages:

ATC-24, SPD-TCCMAR, CUREE, ACI

374 and FEMA 461 protocols

A

Pushed in the plane of the wall

Strong Direction

Weak Direction

Pushed perpendicular to the plane of

the wall

Loading Protocol for Biaxial Loading

Page 39: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

39

Masonry walls were tested via several loading protocols to assess the interaction of in-plane damage over the out-of-plane behavior and vice-versa

Ou

t-o

f-P

lan

e L

oad

In-Plane Load

Simultaneous Loading

Each have certain merits

Difficult to isolate reqd. information to describe the interaction behavior

Ou

t-o

f-P

lan

e L

oad

In-Plane Load

Sequential Loading

IP followed by OOP

OOP followed by IP

IP followed by OOP

OOP followed by IP

Sequential Simultaneous

Static Dynamic

1 23 4

Various Loading Protocols

Page 40: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

40

Masonry panel is subjected simultaneously to bidirectional loading either statically or dynamically

Simultaneous dynamic loading using biaxial shake table (Gülkan et al., 1990; Žarnić et al., 2001)

Simultaneously varying static loading is relatively difficult.

Simultaneous static loading by holding the in-plane deformation and applying the out-of-plane pressure using air bag (Angel et al., 1994; Flanagan and Bennett, 1999)

Simultaneous Loading

Ou

t-o

f-P

lan

e L

oad

In-Plane Load

Ou

t-o

f-P

lan

e L

oad

In-Plane Load

Dynamic Static

Holding in-plane deformation (not truly simultaneous)

Simultaneous loading

Page 41: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

41

In-plane Damage followed by Out-of-plane Load

Significant reduction in out-of-plane capacity with in-plane damage (Angel et al. 1994, Komaraneni et al. 2011)

Sequential loading…

0

0.2

0.4

0.6

0.8

1

1.2

0 0.05 0.1 0.15 0.2 0.25 0.3 0.35

Norm

aliz

ed O

OP

Cap

acity

In-plane Drift (%)

(a)

IP

(b)

(c)

IP

IP

Interaction Curve

PIP POOP

ΔIP

ΔOOP

Agnihotri, P., Singhal, V., and Rai, D. C., “Effect of In-Plane Damage on Out-of-Plane Strength of Unreinforced Masonry

Walls,” Engineering Structures, 57, 1-11.

Page 42: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

42

Several experimental studies were conducted to study such interaction:

apply known in-plane damage to wall specimens before exposing it to out-of-plane loading

Interpretation on Interaction curve: Test results of Angel et al. 1994; Calvi and Bolognini 2001

In-plane Damage followed by Out-of-plane Loads

0

0.2

0.4

0.6

0.8

1

1.2

0 0.2 0.4 0.6 0.8 1

Norm

aliz

ed O

OP

pre

ssure

Normalised IP damage

Significant effect of prior in-plane damage on out-of-plane capacity

Page 43: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

43

Unique loading protocol

involves successive applications of dynamic out-of-plane and static cyclic in-plane loads

Proposed Loading Protocol

White Noise

Level-1 White Noise

Level-II . .

Level-V White Noise

White Noise Level-V White Noise

Out-

of-

pla

ne

loadin

g

In-p

lane

loadin

g

0.10% (DL1) 0.20% (DL2) 0.25% (DL3) 0.35% (DL4) 0.50% (DL5)

DS

1

0.75% (DL6)

1.00% (DL7)

1.40% (DL8)

1.75% (DL9)

DS

2

DS

3

DS

4

DS

5

2.20% (DL10)

DS

6

Test sequence

Page 44: Testing Protocols for Performance Evaluation of Masonry Panels · Characterization of Masonry in Tension 10 Tension Bond Strength: required for masonry walls subjected to wind, eccentric

Thank You !

@ Blondet 2005

Questions and Suggestions…