TEST REPORT APPLICANT : Insung Chemical Corp. Co., Ltd. ADDRESS : #1722, Keumkang Penterium IT Tower, 282, Hagui-ro, Dongan-gu, Anyang-si, Gyeonggi-do, Korea PAGE: 1 of 9 REPORT NO. RT21R-S1306-E DATE: Mar. 03, 2021 SAMPLE DESCRIPTION : The following submitted sample(s) said to be:- NAME/TYPE OF PRODUCT : DOW CORNING™ EA-6900 NAME OF MATERIAL : Silicone SAMPLE ID NO. : RT21R-S1306 MANUFACTURER/VENDOR : Insung Chemical Corp. Co., Ltd. NAME OF BUYER : Amkor technology SAMPLE RECEIVED : Feb. 24, 2021 TESTING DATE : Feb. 24, 2021 ~ Mar. 03, 2021 TEST METHOD(S) : Please see the following page(s). TEST RESULT(S) : Please see the following page(s). * Note 1 : The test results presented in this report refer only to the object tested. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory. Approved by, Authorized by, Authenticity check Jade Jang / Lab. Technical Manager Bo Park / Lab. General Manager Intertek Testing Services Korea Ltd. Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0025 Web Site : intertek.co.kr Seoul Lab. Address : 7, Achasan-ro 5-gil, Seongdong-gu, Seoul, 04793 Korea Ulsan Lab. Address : 34, Yongam-gil, Chongryang-myeon, Ulju-gun, Ulsan 44989 Korea

TEST REPORT - nxp.com

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TEST REPORT - nxp.com

TEST REPORT

APPLICANT : Insung Chemical Corp. Co., Ltd.

ADDRESS : #1722, Keumkang Penterium IT Tower, 282, Hagui-ro, Dongan-gu,

Anyang-si, Gyeonggi-do, Korea

PAGE: 1 of 9

REPORT NO. RT21R-S1306-E DATE: Mar. 03, 2021

SAMPLE DESCRIPTION : The following submitted sample(s) said to be:-

NAME/TYPE OF PRODUCT : DOW CORNING™ EA-6900

NAME OF MATERIAL : Silicone

SAMPLE ID NO. : RT21R-S1306

MANUFACTURER/VENDOR : Insung Chemical Corp. Co., Ltd.

NAME OF BUYER : Amkor technology

SAMPLE RECEIVED : Feb. 24, 2021

TESTING DATE : Feb. 24, 2021 ~ Mar. 03, 2021

TEST METHOD(S) : Please see the following page(s).

TEST RESULT(S) : Please see the following page(s).

* Note 1 : The test results presented in this report refer only to the object tested.

* Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

Approved by, Authorized by,

Authenticity check

Jade Jang / Lab. Technical Manager Bo Park / Lab. General Manager

Intertek Testing Services Korea Ltd. Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0025 Web Site : intertek.co.kr

Seoul Lab. Address : 7, Achasan-ro 5-gil, Seongdong-gu, Seoul, 04793 Korea Ulsan Lab. Address : 34, Yongam-gil, Chongryang-myeon, Ulju-gun, Ulsan 44989 Korea

※ You can verify the forgery and authenticity by the barcode at the end of this document.

Page 2: TEST REPORT - nxp.com

TEST REPORT PAGE: 2 of 9

REPORT NO. RT21R-S1306-E DATE: Mar. 03, 2021

SAMPLE ID NO. : RT21R-S1306

SAMPLE DESCRIPTION : DOW CORNING™ EA-6900

TEST ITEM UNIT TEST METHOD MDL RESULT

Cadmium (Cd) ㎎/㎏ With reference to

IEC 62321-5 Edition 1.0 : 2013, by acid digestion and

determined by ICP-OES

0.5 N.D.

Lead (Pb) ㎎/㎏ 5 N.D.

Mercury (Hg) ㎎/㎏

With reference to IEC 62321-4 : 2013/AMD1 : 2017, by acid digestion and

determined by ICP-OES

2 N.D.

Hexavalent Chromium (Cr 6+) ㎎/㎏

With reference to IEC 62321-7-2

Edition 1.0 : 2017, by alkaline/toluene digestion

and determined by UV-VIS Spectrophotometer

8 N.D.

Polybrominated Biphenyl (PBBs)

Monobromobiphenyl ㎎/㎏

With reference to IEC 62321-6 Edition 1.0 : 2015,

by solvent extraction and determined by GC/MS

5 N.D.

Dibromobiphenyl ㎎/㎏ 5 N.D.

Tribromobiphenyl ㎎/㎏ 5 N.D.

Tetrabromobiphenyl ㎎/㎏ 5 N.D.

Pentabromobiphenyl ㎎/㎏ 5 N.D.

Hexabromobiphenyl ㎎/㎏ 5 N.D.

Heptabromobiphenyl ㎎/㎏ 5 N.D.

Octabromobiphenyl ㎎/㎏ 5 N.D.

Nonabromobiphenyl ㎎/㎏ 5 N.D.

Decabromobiphenyl ㎎/㎏ 5 N.D.

Polybrominated Diphenyl Ether (PBDEs)

Monobromodiphenyl ether ㎎/㎏

With reference to IEC 62321-6 Edition 1.0 : 2015,

by solvent extraction and determined by GC/MS

5 N.D. Dibromodiphenyl ether ㎎/㎏ 5 N.D. Tribromodiphenyl ether ㎎/㎏ 5 N.D. Tetrabromodiphenyl ether ㎎/㎏ 5 N.D. Pentabromodiphenyl ether ㎎/㎏ 5 N.D.

Hexabromodiphenyl ether ㎎/㎏ 5 N.D. Heptabromodiphenyl ether ㎎/㎏ 5 N.D. Octabromodiphenyl ether ㎎/㎏ 5 N.D. Nonabromodiphenyl ether ㎎/㎏ 5 N.D. Decabromodiphenyl ether ㎎/㎏ 5 N.D.

Tested by : Jooyeon Lee, Chano Kim, Hayan Park

Notes : ㎎/㎏ = ppm = parts per million

< = Less than

N.D. = Not detected ( <MDL )

MDL = Method detection limit

Intertek Testing Services Korea Ltd. Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0025 Web Site : intertek.co.kr

Seoul Lab. Address : 7, Achasan-ro 5-gil, Seongdong-gu, Seoul, 04793 Korea Ulsan Lab. Address : 34, Yongam-gil, Chongryang-myeon, Ulju-gun, Ulsan 44989 Korea

※ You can verify the forgery and authenticity by the barcode at the end of this document.

Page 3: TEST REPORT - nxp.com

TEST REPORT PAGE: 3 of 9

REPORT NO. RT21R-S1306-E DATE: Mar. 03, 2021

SAMPLE ID NO. : RT21R-S1306

SAMPLE DESCRIPTION : DOW CORNING™ EA-6900

TEST ITEM UNIT TEST METHOD MDL RESULT

Bromine (Br) ㎎/㎏ With reference to EN 14582, by oxygen combustion with bomb and determined by IC

30 N.D.

Chlorine (Cl) ㎎/㎏ With reference to EN 14582, by oxygen combustion with bomb and determined by IC

30 N.D.

Fluorine (F) ㎎/㎏ With reference to EN 14582, by oxygen combustion with bomb and determined by IC

30 N.D.

Iodine (I) ㎎/㎏ With reference to EN 14582, by oxygen combustion with bomb and determined by IC

30 N.D.

Antimony (Sb) ㎎/㎏ With reference to US EPA

3052, by acid digestion and determined by ICP-OES

2 N.D.

Tested by : Hyojoo Kim, Jooyeon Lee

Notes : ㎎/㎏ = ppm = parts per million

< = Less than

N.D. = Not detected ( <MDL )

MDL = Method detection limit

Intertek Testing Services Korea Ltd. Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0025 Web Site : intertek.co.kr

Seoul Lab. Address : 7, Achasan-ro 5-gil, Seongdong-gu, Seoul, 04793 Korea Ulsan Lab. Address : 34, Yongam-gil, Chongryang-myeon, Ulju-gun, Ulsan 44989 Korea

※ You can verify the forgery and authenticity by the barcode at the end of this document.

Page 4: TEST REPORT - nxp.com

TEST REPORT PAGE: 4 of 9

REPORT NO. RT21R-S1306-E DATE: Mar. 03, 2021

SAMPLE ID NO. : RT21R-S1306

SAMPLE DESCRIPTION : DOW CORNING™ EA-6900

TEST ITEM CAS NO. UNIT TEST METHOD MDL RESULT

Dibutyl phthalate (DBP)

84-74-2 ㎎/㎏

With reference to IEC 62321-8

Edition 1.0 : 2017, by solvent extraction and determined by

GC/MS

50 N.D.

Di(2-ethylhexyl) phthalate (DEHP)

117-81-7 ㎎/㎏ 50 N.D.

Diisononyl phthalate (DINP)

28553-12-0 68515-48-0

㎎/㎏ 100 N.D.

Diisodecyl phthalate (DIDP)

26761-40-0 68515-49-1

㎎/㎏ 100 N.D.

Benzyl butyl phthalate (BBP)

85-68-7 ㎎/㎏ 50 N.D.

Diisobutyl phthalate (DIBP)

84-69-5 ㎎/㎏ 50 N.D.

Tested by : Hayan Park

Notes : ㎎/㎏ = ppm = parts per million

< = Less than

N.D. = Not detected ( <MDL )

MDL = Method detection limit

Intertek Testing Services Korea Ltd. Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0025 Web Site : intertek.co.kr

Seoul Lab. Address : 7, Achasan-ro 5-gil, Seongdong-gu, Seoul, 04793 Korea Ulsan Lab. Address : 34, Yongam-gil, Chongryang-myeon, Ulju-gun, Ulsan 44989 Korea

※ You can verify the forgery and authenticity by the barcode at the end of this document.

Page 5: TEST REPORT - nxp.com

TEST REPORT PAGE: 5 of 9

REPORT NO. RT21R-S1306-E DATE: Mar. 03, 2021

SAMPLE ID NO. : RT21R-S1306

SAMPLE DESCRIPTION : DOW CORNING™ EA-6900

* View of sample as received;-

Intertek Testing Services Korea Ltd. Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0025 Web Site : intertek.co.kr

Seoul Lab. Address : 7, Achasan-ro 5-gil, Seongdong-gu, Seoul, 04793 Korea Ulsan Lab. Address : 34, Yongam-gil, Chongryang-myeon, Ulju-gun, Ulsan 44989 Korea

※ You can verify the forgery and authenticity by the barcode at the end of this document.

Page 6: TEST REPORT - nxp.com

TEST REPORT PAGE: 6 of 9

REPORT NO. RT21R-S1306-E DATE: Mar. 03, 2021

SAMPLE ID NO. : RT21R-S1306

SAMPLE DESCRIPTION : DOW CORNING™ EA-6900

Flow Chart (IEC62321 Edition 1.0)

Receipt

Sampling/Grinding or Cutting

For different material, digest the sample with

appropriate acid*1

Pb, Cd, Hg Cr6+

Confirm the tested samples are

totally dissolved*2

Make up with deionized water

Analyzed by ICP-OES

Get 50cm2 sample

Boiling waterextraction

Make up with deionized waterand add diphenyl-carbazide solution

Analyzed by UV-VIS

Metal

Data

Report

Weigh sample

Polymers / Electronics

PBBs /PBDEs

Weigh sampleand add organic

solvent

Soxhlet extraction or solvent extraction

Concentrate the extract and make up with organic solvent

Analyzed by GC-MS

Add alkaline/toluene solution

Heating

Cool and filterthe extract

Soluble by NMP

No

YES

Completely dissolved and then add alkaline solution

Remarks : *1 : List of appropriate acid : Material Acid added for digestion Polymers HNO3, HCl, HF, H2O2, H3BO3 Metals HNO3, HCl, HF Electronics HNO3, HCl, H2O2, HBF4 *2 : The samples were dissolved totally by pre-conditioning method according to above flow chart.

Intertek Testing Services Korea Ltd. Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0025 Web Site : intertek.co.kr

Seoul Lab. Address : 7, Achasan-ro 5-gil, Seongdong-gu, Seoul, 04793 Korea Ulsan Lab. Address : 34, Yongam-gil, Chongryang-myeon, Ulju-gun, Ulsan 44989 Korea

※ You can verify the forgery and authenticity by the barcode at the end of this document.

Page 7: TEST REPORT - nxp.com

TEST REPORT PAGE: 7 of 9

REPORT NO. RT21R-S1306-E DATE: Mar. 03, 2021

SAMPLE ID NO. : RT21R-S1306

SAMPLE DESCRIPTION : DOW CORNING™ EA-6900

Flow Chart (EN14582)

Receipt

Sample preparation

Sample weighing

Bomb preparation

Analyzed by IC

Data

Report

Oxygen bomb combustion

Absorption solvent preparation of absorption solution

Collection of halidesmake up Vol. 100mL

Cooling, for 1hr

Intertek Testing Services Korea Ltd. Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0025 Web Site : intertek.co.kr

Seoul Lab. Address : 7, Achasan-ro 5-gil, Seongdong-gu, Seoul, 04793 Korea Ulsan Lab. Address : 34, Yongam-gil, Chongryang-myeon, Ulju-gun, Ulsan 44989 Korea

※ You can verify the forgery and authenticity by the barcode at the end of this document.

Page 8: TEST REPORT - nxp.com

TEST REPORT PAGE: 8 of 9

REPORT NO. RT21R-S1306-E DATE: Mar. 03, 2021

SAMPLE ID NO. : RT21R-S1306

SAMPLE DESCRIPTION : DOW CORNING™ EA-6900

Flow Chart (Metal Testing)

Receipt

Sample preparation

Sample measurement

Microwave digestion with HNO3 / HCl / HF

Analyzed by ICP-OES

Total digestion

Data

Report

NO

YES

** Remarks : The samples were dissolved totally by pre-conditioning method according to above flow chart.

Intertek Testing Services Korea Ltd. Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0025 Web Site : intertek.co.kr

Seoul Lab. Address : 7, Achasan-ro 5-gil, Seongdong-gu, Seoul, 04793 Korea Ulsan Lab. Address : 34, Yongam-gil, Chongryang-myeon, Ulju-gun, Ulsan 44989 Korea

※ You can verify the forgery and authenticity by the barcode at the end of this document.

Page 9: TEST REPORT - nxp.com

TEST REPORT PAGE: 9 of 9

REPORT NO. RT21R-S1306-E DATE: Mar. 03, 2021

SAMPLE ID NO. : RT21R-S1306

SAMPLE DESCRIPTION : DOW CORNING™ EA-6900

Flow Chart (Phthalates)

Extraction

Concentration

Clean-up

Concentration

Analyzed by GC-MS

Sample preparation

Data

Report

Receipt

***** End of Report ***** Except where explicitly agreed in writing, all work and services performed by Intertek is subject to our standard Terms and Conditions which can be obtained at our website: http://www.intertek.com/terms/. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. This report is made solely on the basis of your instructions and / or information and materials supplied by you and provide no warranty on the tested sample(s) be truly representative of the sample source. The report is not intended to be a recommendation for any particular course of action, you are responsible for acting as you see fit on the basis of the report results. Intertek is under no obligation to refer to or report upon any facts or circumstances which are outside the specific instructions received and accepts no responsibility to any parties whatsoever, following the issue of the report, for any matters arising outside the agreed scope of the works. This report does not discharge or release you from your legal obligations and duties to any other person. You are the only one authorized to permit copying or distribution of this report (and then only in its entirety). Any such third parties to whom this report may be circulated rely on the content of the report solely at their own risk. This report shall not be reproduced, except in full. This report is not related to the scope of Korea Laboratory Accreditation Scheme.

Intertek Testing Services Korea Ltd. Seoul Office: Tel : 02-6090-9500 Fax : 02-3409-0025 Web Site : intertek.co.kr

Seoul Lab. Address : 7, Achasan-ro 5-gil, Seongdong-gu, Seoul, 04793 Korea Ulsan Lab. Address : 34, Yongam-gil, Chongryang-myeon, Ulju-gun, Ulsan 44989 Korea

※ You can verify the forgery and authenticity by the barcode at the end of this document.