Test report No. : 12510205S Page : 1 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401 13-EM-F0429
RADIO TEST REPORT
Test Report No. : 12510205S
Applicant : TAIYO YUDEN CO., LTD. Type of Equipment : Bluetooth low energy / ANT / 802.15.4 Module Model No. : EYSKBN Test standard : EN 300 328 V2.1.1 (Except radiated emission test) Test Result : Complied
1. This test report shall not be reproduced in full or partial, without the written approval of
UL Japan, Inc. 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the above standard(s). 4. The test results in this report are traceable to the national or international standards. 5. This test report covers Radio technical requirements. It does not cover administrative issues such as
Manual or non-Radio test related Requirements. (if applicable) 6. The all test items in this test report are conducted by UL Japan, Inc. Shonan EMC Lab and Kashima
EMC Lab. 7. The opinions and the interpretations to the result of the description in this report are outside scopes
where UL Japan has been accredited.
Date of test: September 27 to October 23, 2018 Representative test engineer: Yosuke Ishikawa
Engineer Consumer Technology Division
Approved by :
Hikaru ShirasawaEngineer
Consumer Technology Division
RTL02610 The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
There is no testing item of "Non-accreditation".
Test report No. : 12510205S Page : 2 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
REVISION HISTORY
Original Test Report No.: 12510205S
Revision Test report No. Date Page revised Contents -(Original) 12510205S October 29, 2018 - -
Test report No. : 12510205S Page : 3 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
CONTENTS PAGE
SECTION 1: Customer information ................................................................................... 4
SECTION 2: Equipment under test (E.U.T.) ..................................................................... 4
SECTION 3: Test specification, procedures & results ...................................................... 6
SECTION 4: Operation of E.U.T. during testing ............................................................... 9
SECTION 5: Antenna Terminal Conducted Tests .......................................................... 12
APPENDIX 1: Test data ........................................................................................................ 13
RF Output Power ........................................................................................................................ 13 Power Spectral Density ............................................................................................................... 16 Occupied Channel Bandwidth .................................................................................................... 18 Transmitter unwanted emissions in the out-of-band domain ...................................................... 25 Receiver Blocking ....................................................................................................................... 27
APPENDIX 2: Test instruments ........................................................................................... 29
APPENDIX 3: Photographs of test setup ............................................................................. 30
Antenna terminal conducted tests other than Receiver Blocking ............................................... 30 Receiver Blocking ....................................................................................................................... 31
Test report No. : 12510205S Page : 4 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
SECTION 1: Customer information Company Name : TAIYO YUDEN CO., LTD. Address : 8-1,Sakae-cho, Takasaki-shi, Gunma 370-8522 ,Japan Telephone Number : +81-27-324-2313 Facsimile Number : +81-27-324-2314 Contact Person : Hideki Kato
SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : Bluetooth low energy / ANT / 802.15.4 Module Model No. : EYSKBN Serial No. : Refer to Clause 4.2 Rating : DC 3.0 V (DC 1.7 V - DC 5.5 V), 0.02 A Receipt Date of Sample : September 21, 2018 Country of Mass-production : Japan Condition of EUT : Engineering prototype
(Not for Sale: This sample is equivalent to mass-produced items.) Modification of EUT : No Modification by the test lab 2.2 Product Description Model: EYSKBN (referred to as the EUT in this report) is a Bluetooth low energy / ANT / 802.15.4 Module. Clock frequency(ies) in the system : 32 MHz
Test report No. : 12510205S Page : 5 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Radio Specification < Bluetooth (BT) Low Energy (LE) (1 Mbps, 2 Mbps) BLE Long range (500 kbps, 125 kbps)> Radio Type : Transceiver Frequency of Operation : 2402 MHz - 2480 MHz Modulation : GFSK Power Supply (radio part input) : DC 1.7 V - 5.5 V Antenna type : Monopole Antenna Antenna Gain : -0.6 dBi Operating Temperature : -40 deg. C to +105 deg. C < ANT (1 Mbps) > Radio Type : Transceiver Frequency of Operation : 2402 MHz - 2480 MHz Modulation : GFSK Power Supply (radio part input) : DC 1.7 V - 5.5 V Antenna type : Monopole Antenna Antenna Gain : -0.6 dBi Operating Temperature : -40 deg. C to +105 deg. C < Nordic Original (2 Mbps) > Radio Type : Transceiver Frequency of Operation : 2402 MHz - 2480 MHz Modulation : GFSK Power Supply (radio part input) : DC 1.7 V - 5.5 V Antenna type : Monopole Antenna Antenna Gain : -0.6 dBi Operating Temperature : -40 deg. C to +105 deg. C < IEEE802.15.4 > Radio Type : Transceiver Frequency of Operation : 2405 MHz - 2475 MHz Modulation : GFSK Power Supply (radio part input) : DC 1.7 V - 5.5 V Antenna type : Monopole Antenna Antenna Gain : -0.6 dBi Operating Temperature : -40 deg. C to +105 deg. C
Test report No. : 12510205S Page : 6 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
SECTION 3: Test specification, procedures & results 3.1 Test Specification Radio : EN 300 328 V2.1.1 Title : Wideband transmission systems; Data transmission equipment operating in the 2.4GHz ISM
band and using wide band modulation techniques; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
Purpose of test : Compliance with the harmonized RE directive 2014/53/EU. 3.2 Procedures and results
No. Item Test Procedure Limit Remarks Worst margin
Exclusions Results
1 RF output power Clause 5.4.2 Clause 4.3.2.2 Conducted See Data N/A Complied
2 Power Spectral Density
Clause 5.4.3 Clause 4.3.2.3 Conducted See Data N/A Complied
3 Duty cycle, Tx-sequence, Tx-gap
Clause 5.4.2 Clause 4.3.2.4 Conducted - N/A N/A *1)
4 Medium Utilisation (MU) factor
Clause 5.4.2 Clause 4.3.2.5 Conducted - N/A N/A *1)
5 Adaptivity (adaptive equipment using modulations other than FHSS)
Clause 5.4.6 Clause 4.3.2.6 Conducted - N/A N/A *2)
6 Occupied Channel Bandwidth
Clause 5.4.7 Clause 4.3.2.7 Conducted See Data
N/A Complied
7 Transmitter unwanted emissions in the out-of-band domain
Clause 5.4.8 Clause 4.3.2.8 Conducted See Data N/A Complied
8 Transmitter unwanted emissions in the spurious domain
Clause 5.4.9 Clause 4.3.2.9 Radiated -
N/A N/A *3)
9 Receiver Spurious emissions
Clause 5.4.10 Clause 4.3.2.10 Radiated -
N/A N/A *3)
10 Transmitter unwanted emissions in the spurious domain
Clause 5.4.9 Clause 4.3.2.9 Conducted -
N/A N/A *4)
11 Receiver Spurious emissions
Clause 5.4.10 Clause 4.3.2.10 Conducted - N/A N/A *4)
12 Receiver Blocking Clause 5.4.11 Clause 4.3.2.11 Conducted See Data N/A Complied 13 Geo-location capability - Clause 4.3.2.12 - - N/A N/A *5)
Note: UL Japan, Inc.’s EMI Work Procedure 13-EM-W0420. *1) The test is not applicable since the EUT is an adaptive equipment and does not operate in a non-adaptive mode. *2) The test is not applicable since the RF output power of the EUT is less than 10 dBm (e.i.r.p.). *3) The test has not been performed according to the customer’s request. *4) The EUT does not have antenna connector. *5) The EUT does not have Geo-location capability. Symbols: Complied The data of this test item has enough margin, more than the measurement uncertainty. Complied# The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.
3.3 Additions or deviations to standards No addition, exclusion nor deviation has been made from the standard.
Test report No. : 12510205S Page : 7 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
3.4 Uncertainty The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2. Shonan EMC Lab.
Frequency range Uncertainty (+/-)30 MHz - 200 MHz 4.8 dB200 MHz - 1000 MHz 3.6 dB1 GHz - 12.75 GHz 4.4 dB
Antenna terminal test Uncertainty (+/-)Power Measurement above 1 GHz (Average Detector)_SPM-06 0.48 dBPower Measurement above 1 GHz (Average Detector)_SPM-07 0.47 dBPower Measurement above 1 GHz (Average Detector)_SPM-08, 09, 10, 11 1.27 dBPower Measurement above 1 GHz (Average Detector)_SPM-13 0.90 dBConducted emissions Measurement (below 1 GHz) 1.8 dBConducted emissions Power Density Measurement (1 GHz-3 GHz) 1.7 dBConducted emissions Measurement (3 GHz-18 GHz) 2.5 dBConducted emissions Measurement (18 GHz-26.5 GHz) 2.5 dBFrequency Measurement (Spectrum Analyzer) 2.1 x 10^-7Bandwidth Measurement 1.01 %Duty cycle and Time Measurement 0.012 %Temperature 0.95 deg.C.Voltage 0.24 %Humidity 3.4 %Receiver Blocking (Wanted RF Level)_SWT-02 2.82 dBReceiver Blocking (Blocking Signal Level)_SWT-02 2.20 dBReceiver Blocking (Wanted RF Level)_SSG-12 2.73 dBReceiver Blocking (Blocking Signal Level)_SSG-12 2.21 dBReceiver Blocking (Wanted RF Level)_SBT-01 2.80 dBReceiver Blocking (Blocking Signal Level)_SBT-01 2.14 dBReceiver Blocking (Blocking Signal Level)_without tester 1.79 dB
Substitution measurement (EUT height: 1.5 m, Distance: 3 m)
Kashima EMC Lab.
ItemUncertainty
(+/-)1.6 %
0.74 dBConducted emissions Measurement (below 6 GHz) 2.2 dB
2.2 dB0.89 deg. C
0.42 %0.012 %
Item Frequency range Uncertainty (+/-)Radiated emission (Measurement distance: 3 m) 30 MHz - 300 MHz 4.7 dB
300 MHz - 1 GHz 3.6 dB1 GHz - 13 GHz 4.8 dB
2.3 dB
Occupied Channel Bandwidth RF output power, conducted
Time
Receiver Blocking
Conducted emissions Measurement (6 GHz - 18 GHz)Temperature Supply voltages
Test report No. : 12510205S Page : 8 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
3.5 Test Location UL Japan, Inc. Shonan EMC Lab.1-22-3, Megumigaoka, Hiratsuka-shi, Kanagawa-ken 259-1220 JAPANTelephone: +81 463 50 6400, Facsimile: +81 463 50 6401JAB Accreditation No. RTL02610
Test siteIC RegistrationNumber
Width x Depth xHeight (m)
Size of reference ground plane (m) /horizontal conducting plane
Maximummeasurementdistance
No.1 Semi-anechoicchamber
2973D-1 20.6 x 11.3 x 7.65 20.6 x 11.3 10m
No.2 Semi-anechoicchamber
2973D-2 20.6 x 11.3 x 7.65 20.6 x 11.3 10m
No.3 Semi-anechoicchamber
2973D-3 12.7 x 7.7 x 5.35 12.7 x 7.7 5m
No.4 Semi-anechoicchamber
- 8.1 x 5.1 x 3.55 8.1 x 5.1 -
No.1 Shielded room - 6.8 x 4.1 x 2.7 6.8 x 4.1 -No.2 Shielded room - 6.8 x 4.1 x 2.7 6.8 x 4.1 -No.3 Shielded room - 6.3 x 4.7 x 2.7 6.3 x 4.7 -No.4 Shielded room - 4.4 x 4.7 x 2.7 4.4 x 4.7 -No.5 Shielded room - 7.8 x 6.4 x 2.7 7.8 x 6.4 -No.6 Shielded room - 7.8 x 6.4 x 2.7 7.8 x 6.4 -No.8 shielded room - 3.45 x 5.5 x 2.4 3.45 x 5.5 -No.1 Measurementroom
- 2.55 x 4.1 x 2.5 - -
UL Japan, Inc. Kashima EMC Lab.1614 Mushihata, Katori-shi, Chiba-ken, 289-0341 JAPANTelephone: +81 478 88 6500, Facsimile: +81 478 82 3373JAB Accreditation No. : RTL02610
Test siteICRegistrationNumber
Width x Depth xHeight (m)
Size of referenceground plane (m) / horizontalconducting plane
Maximummeasurementdistance
No.1 Open site 4659A-1 6.0 x 5.5 x 2.5 20 x 40 10 m
No.2 Open site 4659A-2 4.4 x 4.4 x 2.15 18 x 20 10 m
No.5 Open site 4659A-5 8.6 x 7.1 x 2.4 18 x 23 10 m
No.1 Shielded room 4659A-1 5.4 x 4.5 x 2.3 - -
No.2 Shielded room 4659A-2 3.6 x 2.7 x 2.3 - -
No.3 Shielded room - 5.4 x 3.6 x 2.3 - -
No.4 Shielded Room - 6.1 x 6.1 x 3.1 - -
No.5 Shielded Room 4659A-5 4.2 x 3.1 x 2.5 - -
No.3 Fully Anechoic Chamber - 7.0 x 3.5 x 3.5 - -
No.6 Semi-anechoic Chamber 4659A-6 8.5 x 5.5 x 5.2 - 3 m
No.10 Semi-anechoic Chamber 4659A-10 18.4 x 9.9 x 7.7 - 10 m
No.11 Semi-anechoic Chamber 4659A-7 9.0 x 6.5 x 5.2 - 3 m
No.1 Measurement room - 5.0 x 3.7 x 2.6 - -
No.2 Measurement room - 4.3 x 4.4 x 2.7 - -
No.3 Measurement room - 4.3 x 4.4 x 2.7 - - 3.6 Test data, Test instruments, and Test set up Refer to APPENDIX.
Test report No. : 12510205S Page : 9 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
SECTION 4: Operation of E.U.T. during testing 4.1 Operating Mode(s)
Mode Remarks* Bluetooth (BT) Low Energy (LE) 1 Mbps Maximum Packet Size, PRBS9 Bluetooth (BT) Low Energy (LE) 2 Mbps Maximum Packet Size, PRBS9 Bluetooth (BT) Low Energy (LE) 125 kbps Maximum Packet Size, PRBS9 Bluetooth (BT) Low Energy (LE) 500 kbps Maximum Packet Size, PRBS9 ANT 1 Mbps 1 Mbps Nordic Original 2 Mbps 2 Mbps IEEE802.15.4 250 kbps 250 kbps *EUT has the power settings by the software as follows;- Power Setting: +8 dBm - Software: 10_BLE_TEST_tool-BT5.xls Radio_test_tool_20180918.xls BLE_DTM_PER_tool_20180712.xls This setting of software is the worst case. Any conditions under the normal use do not exceed the condition of setting. In addition, end users cannot change the settings of the output power of the product.
Details of Operating Mode(s)
Test item Operating mode Tested frequency RF output power, Power Spectral Density
Transmitting (Tx) BT LE 1 Mbps Transmitting (Tx) BT LE 2 Mbps Transmitting (Tx) BT LE 125 kbps Transmitting (Tx) BT LE 500 kbps
2402 MHz 2440 MHz 2480 MHz
Transmitting (Tx) ANT 1 Mbps Transmitting (Tx) Nordic Original 2 Mbps
2402 MHz 2441 MHz 2480 MHz
Transmitting (Tx) IEEE802.15.4 250 kbps 2405 MHz 2440 MHz 2475 MHz
Occupied channel bandwidth, Transmitter unwanted emissions in the out-of-band domain,
Transmitting (Tx) BT LE 1 Mbps Transmitting (Tx) BT LE 2 Mbps Transmitting (Tx) BT LE 125 kbps Transmitting (Tx) BT LE 500 kbps Transmitting (Tx) ANT 1 Mbps Transmitting (Tx) Nordic Original 2 Mbps
2402 MHz 2480 MHz
Transmitting (Tx) IEEE802.15.4 250 kbps 2405 MHz 2475 MHz
Receiver blocking
Communication ANT 1Mbps *1) 2402 MHz 2480 MHz
*1) Test was conducted in the mode with the lowest nominal channel bandwidth.
Extreme test condition Temperature -40 deg. C to +105 deg. C : operating temperature range of EUT Voltage Vnom : DC 3.0 V
Test report No. : 12510205S Page : 10 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
4.2 Configuration and peripherals Other than Receiver blocking test
Description of EUT and Support equipment No. Item Model number Serial number Manufacturer Remark
A Bluetooth low energy / ANT / 802.15.4 Module
EYSKBN 2 *1)6 *2)
TAIYO YUDEN EUT
B Evaluation Board TE8783-1 - TAIYO YUDEN - C Laptop PC PC-VK25TXZCE*3)
CF-T2 *4)2X017171A4CKSA46826
NEC Panasonic
-
D AC Adaptor ADP-75SB EB *3)CF-AA1625A *4)
2837264DE1625AM406Z21913F
NEC Panasonic
-
*1) Used for BT LE 1 Mbps, BT LE 2 Mbps, BT LE 125 kbps, and BT LE 500 kbps *2) Used for ANT 1 Mbps, Nordic Original 2 Mbps and IEEE802.15.4 250 kbps *3) Used for IEEE802.15.4 250 kbps *4) Used outside IEEE802.15.4 250 kbps List of cables used No. Name Length (m) Shield Remark
Cable Connector 1 USB Cable 1.8 Shielded Shielded - 2 DC Cable 0.5 Unshielded Unshielded - 3 DC Cable 1.8 *1)
1.2 *2) Unshielded Unshielded -
4 AC Cable 0.9 *1) 0.8 *2)
Unshielded Unshielded -
*1) Used for IEEE802.15.4 250 kbps *2) Used outside IEEE802.15.4 250 kbps
C
1
GND
2
DC 3 V
A
AC 100 V / 50 Hz
D
3 4
B
Test report No. : 12510205S Page : 11 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Receiver blocking test
* Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions. Description of EUT and Support equipment No. Item Model number Serial number Manufacturer Remark
A Bluetooth low energy / ANT / 802.15.4 Module
EYSKBN 1 TAIYO YUDEN EUT
B Laptop PC CF-T2 4CKSA46826 Panasonic -C AC Adaptor CF-AA1625A 1625AM406Z21913F Panasonic -D Evaluation Board TE8783-1 - TAIYO YUDEN -E Bluetooth low energy /
ANT / 802.15.4 Module EYSKBN 4 TAIYO YUDEN -
F Evaluation Board TE8783-1 - TAIYO YUDEN - List of cables used No. Name Length (m) Shield Remark
Cable Connector 1 USB Cable 1.8 Shielded Shielded - 2 DC Cable 0.5+2.0 Unshielded Unshielded - 3 DC Cable 1.2 Unshielded Unshielded - 4 AC Cable 0.8 Unshielded Unshielded - 5 USB Cable 1.5 Shielded Shielded - 6 DC Cable 0.5 Unshielded Unshielded -
B
1 2DC 3 V
AC 100 V / 50 Hz
C
3 4
D
A
F
E
5 6DC 3 V
Test report No. : 12510205S Page : 12 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
SECTION 5: Antenna Terminal Conducted Tests Test Procedure The tests were made with below setting connected to the antenna port.
The test results are rounded off to two decimals place, so some differences might be observed. The equipment and cables were not used for factor 0.0 dB of the data sheets. Test data : APPENDIX Test result : Pass
Test Instrument used RemarkRF Output Power Power Meter Normal and Extreme conditionsPower Spectral Density Spectrum Analyzer Normal conditionOccupied Channel Bandwidth
Spectrum Analyzer Normal condition
Transmitter unwanted emissions in the out-of band domain
Spectrum Analyzer Normal conditions- Detector mode: RMS - Trace: Max Hold - Band power was used on behalf of the time domain power function. - Filter mode: Gaussian Filter Since the data in this test report has enough margin
Receiver Blocking - Normal condition
Test report No. : 12510205S Page : 13 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
APPENDIX 1: Test data
RF Output Power
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room
Kashima EMC Lab. No.2 Measurement Room Date (Shonan EMC Lab.)
September 27, 2018 (Kashima EMC Lab.)October 23, 2018
Temperature / Humidity 25 deg. C / 49 % RH 22 deg. C / 48 % RH Engineer Yosuke Ishikawa Hiromitsu Tanabe Mode Tx
BT LE 1 Mbps
Freq. P/M (AV) Cable Atten. Antenna Result Limit MarginTemp. Volt. Reading Loss Loss Gain
[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -14.53 1.69 20.02 -0.60 6.58 20.00 13.422440.0 -14.44 1.70 20.02 -0.60 6.68 20.00 13.322480.0 -14.61 1.71 20.02 -0.60 6.52 20.00 13.482402.0 -14.02 1.69 20.02 -0.60 7.09 20.00 12.912440.0 -13.84 1.70 20.02 -0.60 7.28 20.00 12.722480.0 -13.99 1.71 20.02 -0.60 7.14 20.00 12.862402.0 -14.30 1.02 20.01 -0.60 6.13 20.00 13.872440.0 -14.27 1.03 20.01 -0.60 6.17 20.00 13.832480.0 -14.28 1.03 20.01 -0.60 6.16 20.00 13.84
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
Test Condition
nom nom
min
max nom
nom
BT LE 2 MbpsFreq. P/M (AV) Cable Atten. Antenna Result Limit Margin
Temp. Volt. Reading Loss Loss Gain[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -14.53 1.69 20.02 -0.60 6.58 20.00 13.422440.0 -14.42 1.70 20.02 -0.60 6.70 20.00 13.302480.0 -14.60 1.71 20.02 -0.60 6.53 20.00 13.472402.0 -14.02 1.69 20.02 -0.60 7.09 20.00 12.912440.0 -13.82 1.70 20.02 -0.60 7.30 20.00 12.702480.0 -13.98 1.71 20.02 -0.60 7.15 20.00 12.852402.0 -14.29 1.02 20.01 -0.60 6.14 20.00 13.862440.0 -14.27 1.03 20.01 -0.60 6.17 20.00 13.832480.0 -14.28 1.03 20.01 -0.60 6.16 20.00 13.84
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
Test Condition
nom nom
min
max nom
nom
BT LE 125 kbps
Freq. P/M (AV) Cable Atten. Antenna Result Limit MarginTemp. Volt. Reading Loss Loss Gain
[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -14.55 1.69 20.02 -0.60 6.56 20.00 13.442440.0 -14.44 1.70 20.02 -0.60 6.68 20.00 13.322480.0 -14.62 1.71 20.02 -0.60 6.51 20.00 13.492402.0 -14.05 1.69 20.02 -0.60 7.06 20.00 12.942440.0 -13.86 1.70 20.02 -0.60 7.26 20.00 12.742480.0 -14.00 1.71 20.02 -0.60 7.13 20.00 12.872402.0 -14.30 1.02 20.01 -0.60 6.13 20.00 13.872440.0 -14.27 1.03 20.01 -0.60 6.17 20.00 13.832480.0 -14.28 1.03 20.01 -0.60 6.16 20.00 13.84
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
nom
Test Condition
nom nom
min
max nom
Test report No. : 12510205S Page : 14 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
RF Output Power
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room
Kashima EMC Lab. No.2 Measurement Room Date (Shonan EMC Lab.)
September 27, 2018 (Shonan EMC Lab.) October 1, 2018
(Kashima EMC Lab.) October 23, 2018
Temperature / Humidity 25 deg. C / 49 % RH 25 deg. C / 59 % RH 22 deg. C / 48 % RH Engineer Yosuke Ishikawa Shiro Kobayashi Hiromitsu Tanabe Mode Tx
BT LE 500 kbps
Freq. P/M (AV) Cable Atten. Antenna Result Limit MarginTemp. Volt. Reading Loss Loss Gain
[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -14.54 1.69 20.02 -0.60 6.57 20.00 13.432440.0 -14.43 1.70 20.02 -0.60 6.69 20.00 13.312480.0 -14.62 1.71 20.02 -0.60 6.51 20.00 13.492402.0 -14.03 1.69 20.02 -0.60 7.08 20.00 12.922440.0 -13.85 1.70 20.02 -0.60 7.27 20.00 12.732480.0 -13.99 1.71 20.02 -0.60 7.14 20.00 12.862402.0 -14.31 1.02 20.01 -0.60 6.12 20.00 13.882440.0 -14.28 1.03 20.01 -0.60 6.16 20.00 13.842480.0 -14.29 1.03 20.01 -0.60 6.15 20.00 13.85
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
Test Condition
nom nom
min
max nom
nom
ANT 1 MbpsFreq. P/M (AV) Cable Atten. Antenna Result Limit Margin
Temp. Volt. Reading Loss Loss Gain[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -14.38 1.69 20.02 -0.60 6.73 20.00 13.272441.0 -14.32 1.70 20.02 -0.60 6.80 20.00 13.202480.0 -14.52 1.71 20.02 -0.60 6.61 20.00 13.392402.0 -13.84 1.69 20.02 -0.60 7.27 20.00 12.732441.0 -13.72 1.70 20.02 -0.60 7.40 20.00 12.602480.0 -13.90 1.71 20.02 -0.60 7.23 20.00 12.772402.0 -14.10 1.02 20.01 -0.60 6.33 20.00 13.672441.0 -14.11 1.03 20.01 -0.60 6.33 20.00 13.672480.0 -14.15 1.03 20.01 -0.60 6.29 20.00 13.71
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
Test Condition
nom nom
min
max nom
nom
Nordic Original 2 Mbps
Freq. P/M (AV) Cable Atten. Antenna Result Limit MarginTemp. Volt. Reading Loss Loss Gain
[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2402.0 -14.37 1.69 20.02 -0.60 6.74 20.00 13.262441.0 -14.30 1.70 20.02 -0.60 6.82 20.00 13.182480.0 -14.52 1.71 20.02 -0.60 6.61 20.00 13.392402.0 -13.84 1.69 20.02 -0.60 7.27 20.00 12.732441.0 -13.72 1.70 20.02 -0.60 7.40 20.00 12.602480.0 -13.89 1.71 20.02 -0.60 7.24 20.00 12.762402.0 -14.10 1.02 20.01 -0.60 6.33 20.00 13.672441.0 -14.10 1.03 20.01 -0.60 6.34 20.00 13.662480.0 -14.15 1.03 20.01 -0.60 6.29 20.00 13.71
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
Test Condition
nom nom
min
max nom
nom
Test report No. : 12510205S Page : 15 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
RF Output Power
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room
Kashima EMC Lab. No.2 Measurement Room Date (Shonan EMC Lab.)
October 1, 2018 (Shonan EMC Lab.) October 12, 2018
(Kashima EMC Lab.) October 23, 2018
Temperature / Humidity 25 deg. C / 59 % RH 25 deg. C / 36 % RH 22 deg. C / 48 % RH Engineer Shiro Kobayashi Kazutaka Takeyama Hiromitsu Tanabe Mode Tx
IEEE802.15.4 250 kbps
Freq. P/M (AV) Cable Atten. Antenna Result Limit MarginTemp. Volt. Reading Loss Loss Gain
[MHz] [dBm] [dB] [dB] [dBi] [dBm] [dBm] [dB]2405.0 -14.27 1.69 20.02 -0.60 6.84 20.00 13.162440.0 -14.20 1.70 20.02 -0.60 6.92 20.00 13.082475.0 -14.37 1.71 20.02 -0.60 6.76 20.00 13.242405.0 -13.87 1.69 20.02 -0.60 7.24 20.00 12.762440.0 -13.75 1.70 20.02 -0.60 7.37 20.00 12.632475.0 -13.96 1.71 20.02 -0.60 7.17 20.00 12.832405.0 -14.09 1.02 20.01 -0.60 6.34 20.00 13.662440.0 -14.10 1.03 20.01 -0.60 6.34 20.00 13.662475.0 -14.14 1.03 20.01 -0.60 6.30 20.00 13.70
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
max nom
nom
Test Condition
nom nom
min
Test report No. : 12510205S Page : 16 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Power Spectral Density
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room Date September 27, 2018 Temperature / Humidity 25 deg. C / 49 % RH Engineer Yosuke Ishikawa Mode Tx
BT LE 1Mbps
Ch S/A S/A RF Output Result Limit MarginTemp. Volt. Freq. Maximum Total Power Power
Reading Reading[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]
2402.00 -3.94 -3.87 6.58 6.51 10.00 3.492440.00 -4.18 -4.10 6.68 6.60 10.00 3.402480.00 -4.29 -4.21 6.52 6.44 10.00 3.56
Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)
(*1) Integrated value of 2400 MHz to 2483.5 MHz
(*2) Refer to RF Output Power
Test Condition
nom nom
BT LE 2 MbpsCh S/A S/A RF Output Result Limit Margin
Temp. Volt. Freq. Maximum Total Power PowerReading Reading
[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -6.73 -5.58 6.58 5.43 10.00 4.572440.00 -6.65 -5.49 6.70 5.54 10.00 4.462480.00 -6.74 -5.57 6.53 5.36 10.00 4.64
Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)
(*1) Integrated value of 2400 MHz to 2483.5 MHz
(*2) Refer to RF Output Power
Test Condition
nom nom
BT LE 125 kbpsCh S/A S/A RF Output Result Limit Margin
Temp. Volt. Freq. Maximum Total Power PowerReading Reading
[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -3.25 -3.19 6.56 6.50 10.00 3.502440.00 -3.45 -3.37 6.68 6.61 10.00 3.392480.00 -3.59 -3.52 6.51 6.44 10.00 3.56
Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)
(*1) Integrated value of 2400 MHz to 2483.5 MHz
(*2) Refer to RF Output Power
Test Condition
nom nom
BT LE 500kbpsCh S/A S/A RF Output Result Limit Margin
Temp. Volt. Freq. Maximum Total Power PowerReading Reading
[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -3.08 -3.02 6.57 6.50 10.00 3.502440.00 -3.12 -3.05 6.69 6.62 10.00 3.382480.00 -3.42 -3.35 6.51 6.44 10.00 3.56
Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)
(*1) Integrated value of 2400 MHz to 2483.5 MHz
(*2) Refer to RF Output Power
Test Condition
nom nom
Test report No. : 12510205S Page : 17 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Power Spectral Density
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room Date September 27, 2018 October 1, 2018 October 12, 2018 Temperature / Humidity 25 deg. C / 49 % RH 25 deg. C / 59 % RH 25 deg. C / 36 % RH Engineer Yosuke Ishikawa Shiro Kobayashi Kazutaka Takeyama Mode Tx
ANT 1 Mbps
Ch S/A S/A RF Output Result Limit MarginTemp. Volt. Freq. Maximum Total Power Power
Reading Reading[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]
2402.00 -3.44 -3.41 6.73 6.71 10.00 3.292441.00 -3.66 -3.63 6.80 6.77 10.00 3.232480.00 -3.91 -3.89 6.61 6.58 10.00 3.42
Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)
(*1) Integrated value of 2400 MHz to 2483.5 MHz
(*2) Refer to RF Output Power
Test Condition
nom nom
Nordic Original 2 MbpsCh S/A S/A RF Output Result Limit Margin
Temp. Volt. Freq. Maximum Total Power PowerReading Reading
[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2402.00 -4.16 -3.81 6.74 6.39 10.00 3.612441.00 -4.19 -3.83 6.82 6.46 10.00 3.542480.00 -4.43 -4.07 6.61 6.25 10.00 3.75
Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)
(*1) Integrated value of 2400 MHz to 2483.5 MHz
(*2) Refer to RF Output Power
Test Condition
nom nom
IEEE802.15.4 250 kbpsCh S/A S/A RF Output Result Limit Margin
Temp. Volt. Freq. Maximum Total Power PowerReading Reading
[MHz] [dBm/MHz] [dBm] [dBm] [dBm/MHz] [dBm/MHz] [dB]2405.00 -4.45 -2.92 -3.33 -4.86 10.00 14.862440.00 -4.32 -2.76 -3.26 -4.81 10.00 14.812475.00 -4.42 -2.88 -3.42 -4.97 10.00 14.97
Result [dBm/MHz] = S/A Maximum Reading [dBm/MHz] - S/A Total Power Reading [dBm] (*1) + RF Output Power [dBm] (*2)
(*1) Integrated value of 2400 MHz to 2483.5 MHz
(*2) Refer to RF Output Power
Test Condition
nom nom
Test report No. : 12510205S Page : 18 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Occupied Channel Bandwidth
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room Date September 27, 2018 Temperature / Humidity 25 deg. C / 49 % RH Engineer Yosuke Ishikawa Mode Tx BT LE 1Mbps
Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 1.0574 2401.4713 > 24002480 1.0618 2480.5309 < 2483.5
Tx 2402 MHz Tx 2480 MHz
Test report No. : 12510205S Page : 19 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Occupied Channel Bandwidth
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room Date September 27, 2018 Temperature / Humidity 25 deg. C / 49 % RH Engineer Yosuke Ishikawa Mode Tx BT LE 2 Mbps
Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 2.0667 2400.9667 > 24002480 2.0749 2481.0375 < 2483.5
Tx 2402 MHz Tx 2480 MHz
Test report No. : 12510205S Page : 20 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Occupied Channel Bandwidth
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room Date September 27, 2018 Temperature / Humidity 25 deg. C / 49 % RH Engineer Yosuke Ishikawa Mode Tx BT LE 125 kbps
Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 1.0468 2401.4766 > 24002480 1.0520 2480.5260 < 2483.5
Tx 2402 MHz Tx 2480 MHz
Test report No. : 12510205S Page : 21 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Occupied Channel Bandwidth
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room Date September 27, 2018 Temperature / Humidity 25 deg. C / 49 % RH Engineer Yosuke Ishikawa Mode Tx BT LE 500 kbps
Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 1.0438 2401.4781 > 24002480 1.0500 2480.5250 < 2483.5
Tx 2402 MHz Tx 2480 MHz
Test report No. : 12510205S Page : 22 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Occupied Channel Bandwidth
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room Date September 27, 2018 Temperature / Humidity 25 deg. C / 49 % RH Engineer Yosuke Ishikawa Mode Tx ANT 1 Mbps
Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 0.9100 2401.5450 > 24002480 0.9163 2480.4582 < 2483.5
Tx 2402 MHz Tx 2480 MHz
Test report No. : 12510205S Page : 23 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Occupied Channel Bandwidth
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room Date September 27, 2018 Temperature / Humidity 25 deg. C / 49 % RH Engineer Yosuke Ishikawa Mode Tx Nordic Original 2 Mbps
Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2402 1.7836 2401.1082 > 24002480 1.7946 2480.8973 < 2483.5
Tx 2402 MHz Tx 2480 MHz
Test report No. : 12510205S Page : 24 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Occupied Channel Bandwidth
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room Date October 1, 2018 October 12, 2018 Temperature / Humidity 25 deg. C / 59 % RH 25 deg. C / 36 % RH Engineer Shiro Kobayashi Kazutaka Takeyama Mode Tx IEEE802.15.4 250 kbps
Frequency Bandwidth Result Limit[MHz] [MHz] [MHz] [MHz]2405 2.2235 2403.8883 > 24002475 2.2248 2476.1124 < 2483.5
Tx 2405 MHz Tx 2475 MHz
Test report No. : 12510205S Page : 25 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Transmitter unwanted emissions in the out-of-band domain
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room Date September 27, 2018 October 1, 2018 Temperature / Humidity 25 deg. C / 49 % RH 25 deg. C / 59 % RH Engineer Yosuke Ishikawa Shiro Kobayashi Mode Tx
BT LE 1 MbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks
Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]2398.4 -56.88 1.69 9.85 -0.60 -45.94 -20.00 25.94 Lowest ch 2400 MHz - 2 BW2399.5 -52.37 1.69 9.85 -0.60 -41.43 -10.00 31.43 Lowest ch 2400 MHz - BW2484.0 -58.33 1.71 9.84 -0.60 -47.38 -10.00 37.38 Highest ch 2483.5 MHz + BW2485.1 -60.20 1.71 9.84 -0.60 -49.25 -20.00 29.25 Highest ch 2483.5 MHz + 2 BW
BT LE 2 MbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks
Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]2397.4 -56.36 1.69 9.85 -0.60 -45.42 -20.00 25.42 Lowest ch 2400 MHz - 2 BW2399.5 -40.24 1.69 9.85 -0.60 -29.30 -10.00 19.30 Lowest ch 2400 MHz - BW2484.0 -54.95 1.71 9.84 -0.60 -44.00 -10.00 34.00 Highest ch 2483.5 MHz + BW2486.1 -57.24 1.71 9.84 -0.60 -46.29 -20.00 26.29 Highest ch 2483.5 MHz + 2 BW
BT LE 125 kbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks
Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]2398.5 -56.04 1.69 9.85 -0.60 -45.10 -20.00 25.10 Lowest ch 2400 MHz - 2 BW2399.5 -49.53 1.69 9.85 -0.60 -38.59 -10.00 28.59 Lowest ch 2400 MHz - BW2484.0 -57.54 1.71 9.84 -0.60 -46.59 -10.00 36.59 Highest ch 2483.5 MHz + BW2485.1 -59.95 1.71 9.84 -0.60 -49.00 -20.00 29.00 Highest ch 2483.5 MHz + 2 BW
BT LE 500 kbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks
Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]2398.5 -55.20 1.69 9.85 -0.60 -44.26 -20.00 24.26 Lowest ch 2400 MHz - 2 BW2399.5 -50.94 1.69 9.85 -0.60 -40.00 -10.00 30.00 Lowest ch 2400 MHz - BW2484.0 -56.89 1.71 9.84 -0.60 -45.94 -10.00 35.94 Highest ch 2483.5 MHz + BW2485.1 -59.15 1.71 9.84 -0.60 -48.20 -20.00 28.20 Highest ch 2483.5 MHz + 2 BW
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
*Above test result was maximum value on each 1 BW.
Test report No. : 12510205S Page : 26 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Transmitter unwanted emissions in the out-of-band domain
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room Date September 27, 2018 October 1, 2018 October 12, 2018 Temperature / Humidity 25 deg. C / 49 % RH 25 deg. C / 59 % RH 25 deg. C / 36 % RH Engineer Yosuke Ishikawa Shiro Kobayashi Kazutaka Takeyama Mode Tx
ANT 1 MbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks
Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]2398.5 -58.14 1.69 9.85 -0.60 -47.20 -20.00 27.20 Lowest ch 2400 MHz - 2 BW2399.5 -53.22 1.69 9.85 -0.60 -42.28 -10.00 32.28 Lowest ch 2400 MHz - BW2484.0 -59.26 1.71 9.84 -0.60 -48.31 -10.00 38.31 Highest ch 2483.5 MHz + BW2485.0 -60.67 1.71 9.84 -0.60 -49.72 -20.00 29.72 Highest ch 2483.5 MHz + 2 BW
Nordic Original 2 MbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks
Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]2397.7 -56.95 1.69 9.85 -0.60 -46.01 -20.00 26.01 Lowest ch 2400 MHz - 2 BW2399.5 -44.62 1.69 9.85 -0.60 -33.68 -10.00 23.68 Lowest ch 2400 MHz - BW2484.0 -56.14 1.71 9.84 -0.60 -45.19 -10.00 35.19 Highest ch 2483.5 MHz + BW2485.8 -58.25 1.71 9.84 -0.60 -47.30 -20.00 27.30 Highest ch 2483.5 MHz + 2 BW
IEEE802.15.4 250 kbpsFrequency S/A (AV) Cable Atten. Antenna Result Limit Margin Remarks
Reading Loss Loss Gain[MHz] [dBm/MHz] [dB] [dB] [dBi] [dBm/MHz] [dBm/MHz] [dB]2396.3 -57.49 1.69 9.85 -0.60 -46.55 -20.00 26.55 Lowest ch 2400 MHz - 2 BW2399.5 -52.85 1.69 9.85 -0.60 -41.91 -10.00 31.91 Lowest ch 2400 MHz - BW2484.0 -59.12 1.71 9.84 -0.60 -48.17 -10.00 38.17 Highest ch 2483.5 MHz + BW2486.2 -59.30 1.71 9.84 -0.60 -48.35 -20.00 28.35 Highest ch 2483.5 MHz + 2 BW
Result = Reading + Cable Loss (including the cable(s) customer supplied) + Attenuator Loss + Antenna Gain
*Above test result was maximum value on each 1 BW.
Test report No. : 12510205S Page : 27 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Receiver Blocking
Report No. 12510205S Test place Shonan EMC Lab. No.5 Shielded Room Date October 3, 2018 Temperature / Humidity 26 deg. C / 47 % RH Engineer Yosuke Ishikawa Mode Communication ANT 1Mbps
Lowest Channel Highest ChannelPmin -87.87 -89.62
Pmin + 6 dB -81.87 -83.62
Receiver Category 2 equipment
2380 0.002503.5 0.012300 0.00
2583.5 0.012380 0.07
2503.5 0.052300 0.00
2583.5 0.00
*Pmin is the minimum level of wanted signal (in dBm) required to meet the minimum performance criterion a PER less than or equal to 10 % in the absence of any blocking signal.*The test was performed Blocking signal power levels corrected by the actual antenna assembly gain.
Pmin + 6 dB -47
HighestChannel
Wanted signal meanpower from
companion device(dBm)
MeasuredReceiver Sensitivity
(corrected by the actual antenna assemblygain)
OperatingChannel
Wanted signal meanpower from
companion device(dBm)
Blocking signalfrequency
(MHz)
Blocking signal power(dBm) *1)
LowestChannel Pmin + 6 dB -47
Pmin + 6 dB -57
Pmin + 6 dB -57
ResultPER(%)
LimitPER(%)
≦10
≦10
*1) Blocking signal power was adjusted by assumed antenna gain 0.0 dBi since it was more severe condition.
Test report No. : 12510205S Page : 28 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
CONDUCTED METHODS SYSTEM BLOCK DIAGRAM of Receiver Blocking
PC Competitor
Power Splitters/ Combiners
Signal Generator
EUT Step Attenuator
Test report No. : 12510205S Page : 29 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
APPENDIX 2: Test instruments
Test Instruments
Local ID Test
Name LIMS
ID Description Manufacturer Model Serial
Last Calibration
Date
Calibration Due Date
Calibration Interval (Month)
KTS-07 AT 145111 Digital Tester SANWA PC500 7019232 2017/10/11 2018/10/31 12SAT10-16 AT 160494 Attenuator Weinschel Corp. 54A-10 83406 2017/12/8 2018/12/31 12
SCC-G14 AT 145175 Coaxial Cable Suhner SUCOFLEX 102
31600/2 2018/3/19 2019/3/31 12
SCH-01 AT 145200 Temperature and Humidity Chamber
ESPEC PL-1KT 14020837 2018/4/11 2019/4/30 12
SPM-08 AT 146268 Power Meter DARE!! Instruments
RPR3006W 15I00041SNO73
2018/8/3 2019/8/31 12
SSA-01 AT 146223 Spectrum Analyzer
AGILENT N9010A-526 MY48031482
2018/4/16 2019/4/30 12
SSA-02 AT 145800 Spectrum Analyzer
AGILENT E4448A MY48250106
2018/3/5 2019/3/31 12
SOS-09 AT,RB 146318 Humidity Indicator
A&D AD-5681 4061484 2017/12/21 2018/12/31 12
CCC-W01 AT 143109 Micro Wave
Cable Suhner SUCOFLEX102 MY3662/
2 2018/05/25 2019/05/31 12
CAT20-05 AT 143042 20dB Fixed
Atten. WEINSCHEL 54A-20 42054 2018/05/21 2019/05/31 12
CTS-18 AT 144220 Digital
Multimeter Fluke Corporation
87-3 85220051 2018/10/01 2019/10/31 12
COS-05 AT 143537 Temperature
& Humidity Indicator
A&D AD-5681 6975761 2018/07/18 2019/07/31 12
CPM-16 AT 143588 Peak Power
Analyzer AGILENT 8990B MY5100
0276 2018/06/20 2019/06/30 12
CPSO-24 AT 143606 Power Sensor AGILENT N1923A MY5407
0024 2018/06/20 2019/06/30 12
CCH-04 AT 143181 Temperature
and Humidity Chamber
ESPEC PL-1J 15004059 2018/07/09 2019/07/31 12
CBM-05 AT 143128 Barometer OTA No.11 15404 2015/11/18 2018/11/30 36KTS-06 RB 145110 Digital Tester SANWA PC500 7019240 2018/3/5 2019/3/31 12
SCC-G34 RB 151611 Coaxial Cable Junkosha MWX241-01000KMSKMS/B
1612Q032
2018/1/25 2019/1/31 12
SCC-G35 RB 151612 Coaxial Cable Junkosha MWX241-01000KMSKMS/B
1612Q033
2018/1/25 2019/1/31 12
SCC-G36 RB 151613 Coaxial Cable Junkosha MWX241-01000KMSKMS/B
1612Q034
2018/1/25 2019/1/31 12
SCC-G37 RB 151614 Coaxial Cable Junkosha MWX241-01000KMSKMS/B
1612Q035
2018/1/25 2019/1/31 12
SPSC-08 RB 146277 Power Splitters/Combiners
Mini-Circuits ZFSC-2-10G+ - 2018/7/30 2019/7/31 12
SSAT-01 RB 167151 Step Attenuator
KEYSIGHT 8494B MY42157639
2018/2/7 2019/2/28 12
SSAT-02 RB 167152 Step Attenuator
KEYSIGHT 8496B MY42151198
2018/2/7 2019/2/28 12
SSG-12 RB 146257 Signal Generator
Rohde & Schwarz
SMBV100A 262152 2018/7/31 2019/7/31 12
The expiration date of the calibration is the end of the expired month. All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or international standards.
As for some calibrations performed after the tested dates, those test equipment have been controlled by means of an unbroken chains of calibrations.
Test item: AT: Antenna Terminal Conducted test RB: Receiver Blocking test
Test report No. : 12510205S Page : 30 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
APPENDIX 3: Photographs of test setup
Antenna terminal conducted tests other than Receiver Blocking
(Shonan EMC Lab.)
(Kashima EMC Lab.)
Test report No. : 12510205S Page : 31 of 31 Issued date : October 29, 2018
UL Japan, Inc. Shonan EMC Lab. 1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN Telephone : +81 463 50 6400 Facsimile : +81 463 50 6401
Receiver Blocking
End of Report