1
www.hydrosense-legionella.com Email: [email protected] Telephone UK: +44 (0)131 560 1340 Telephone USA (Toll Free): (855) 894 0404 HYDROSENSE® High Legionella pneumophila Antigen 80– 90Yes Low Yes 25 minutes Yes PCR High Legionella pneumophila DNA 80– 90Yes High No 1 – 3 days (depending on transport) No CULTURE Moderate to High Legionella pneumophila Colony Forming Units – CFUs 10– 60No High No 10 – 14 days No Sensitivity to dangerous strains of Legionella What is being measured? Reliability (Recovery Rate) Detects dangerous form of Legionella pneumophila Level of expertise required On-site result Speed of result Results certificate immediately available ALB-tcs-14-01 Reliable self testing for Legionella Comparison of Legionella testing techniques: Hydrosense® , PCR and Culture

Test Method Comparison - Amazon Web Services

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Test Method Comparison - Amazon Web Services

www.hydrosense-legionella.com Email: [email protected] Telephone UK: +44 (0)131 560 1340 Telephone USA (Toll Free): (855) 894 0404

Direct Legionella Field Test Kit™

Tests water from any source directly

Good sensitivity: 100,000 CFU/litre

Lowest cost test

Simplest, fastest test

Frequent sampling at lower sensitivity

10 tests per kit

Result in 25 minutes

Part no: 100104

RRP (1 kit): £425.00

HYDROSENSE®

High

Legionella pneumophila Antigen

80� – 90�

Yes

Low

Yes

25 minutes

Yes

PCR

High

Legionella pneumophila DNA

80� – 90�

Yes

High

No

1 – 3 days (depending on transport)

No

CULTURE

Moderate to High

Legionella pneumophila Colony Forming Units – CFUs

10� – 60�

No

High

No

10 – 14 days

No

Sensitivity to dangerous strains of Legionella

What is being measured?

Reliability (Recovery Rate)

Detects dangerous form of Legionella pneumophila

Level of expertise required

On-site result

Speed of result

Results certificate immediately available

ALB-tcs-14-01

Reliable self testingfor Legionella

Comparison of Legionella testing techniques:Hydrosense®, PCR and Culture