24
Wireless Controlled Door with Key Solution family: Interior/Exterior door solutions Solution group: Single-Steel/Wood-Self Closing-Access Control Description TESA ASSA ABLOY solution for double-control Door by Wall Reader - the reader operates on the electromechanical lock, which monitors both sides of the Door. Motorized lock for Monitoring signals and Fire signals. Typical application markets For all kinds of buildings, particularly Hospitals, Hotels, Offices, Institutional Buildings, Stations, Airports and Leisure Spots SMARTair™ wall reader, Standard: ISO 14025, EN 15804 (EPD-ASA-20150166-IBA1- EN) ABLOY EL 561 electromechanical lock, Standards: EN 179, EN 1125, EN 1634, EN 14846 Patented security cylinder, TESA's TX80, Standard: EN 1303 Handle with rose, TESA's SENA series, AISI 316 quality, Use Category: 3, Standard: EN1906 ASSA ABLOY Cam-Motion® DC 500 door closer and guide, Standard: EN1154, DDA/CEN PR 15894, EN 15804 (EPD-ASA- 20130275-IBC1-EN) Doorstop Hardware set Exterior Interior EB1-MT-F-C-ES15_EN Set ID: Version: 1 https://www.tesa.es TESA ASSA ABLOY Tel: +34 91 6785565

TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

Wireless Controlled Door with Key

Solution family: Interior/Exterior door solutionsSolution group: Single-Steel/Wood-Self Closing-Access Control

Description

TESA ASSA ABLOY solution for double-controlDoor by Wall Reader - the reader operates onthe electromechanical lock, which monitors bothsides of the Door.

Motorized lock for Monitoring signals and Firesignals.

Typical application markets

For all kinds of buildings, particularly Hospitals, Hotels, Offices, Institutional Buildings, Stations, Airports and Leisure Spots

SMARTair™ wall reader, Standard: ISO14025, EN 15804 (EPD-ASA-20150166-IBA1-EN)

ABLOY EL 561 electromechanical lock,Standards: EN 179, EN 1125, EN 1634, EN14846

Patented security cylinder, TESA's TX80,Standard: EN 1303

Handle with rose, TESA's SENA series, AISI316 quality, Use Category: 3, Standard:EN1906

ASSA ABLOY Cam-Motion® DC 500 doorcloser and guide, Standard: EN1154,DDA/CEN PR 15894, EN 15804 (EPD-ASA-20130275-IBC1-EN)

Doorstop

Hardware set

Exterior

Interior

EB1-MT-F-C-ES15_ENSet ID:Version: 1

https://www.tesa.esTESA ASSA ABLOYTel: +34 91 6785565

Page 2: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

ASSA ABLOY, the global leader in door opening solutions

SMARTair™ wired wall readers with RFID reader are suitable for automated doors, turnstiles, barriers, elevators or any access in which the locking or blocking element is an automatism. The wall reader incorporates a relay and a control unit which manages both the reader and the relay.

SMARTair™ Wall ReaderPro Wireless Online

Technical data - SMARTair™ Wall reader

Traffic volume High

Exterior usage IP55 (Wall reader)Up to 85% humidity-20°C to + 80°C (Wall reader)-10ºC to + 80ºC (Relay board)

Hardware compatibility and installation

To be combined with electromechanical devices to unlock the door (e.g. electric strike plates, electromagnetic locks or escape routes) Cabling needed

Power supply Cabled 12-24 VAC – VDC: powered through relay boardMax power consumption (reader + relay board): 500mA @ 12V / 250mA @ 24V

Multi- authentication

No

Status information

Door position (door sensor not included)Request to exitTamper

Certifications CE (EMC, R&TTE)ROHS, REACH, WEE

RFID technologies

HID iCLASS® MIFARE Classic and UltralightSKIDATADESFire

Upgradability SMARTair™ Wall readers* can be upgradeable from Standalone > Offline / Update On Card > Wireless Online by:· Adding RF module· Firmware upgrade

* R4 circuit required.

MURALMURAL R4

25

77

121

25

77

121

Page 3: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

Reader Module · Reading distance: 2-4 cm read/write distance with

standard RFID credentials.· Emergency opening: Jack connection is available

to connect the portable programmer and emergency kit.

· RFID reader with LED (green/red) and sound buzzer for different warning signals: access authorized or denied, etc.

Control Unit· Upgradeable firmware.· Non-volatile memory. The wall reader can be

programmed to operate in 2 modes: · Normal mode: 1500 users and 600 events.· High traffic door: unlimited number of users

filtered into 48 groups (permissions). Stores 1000 events.

· Real-time clock and calendar: · 14 time zones with 5 time periods (week days

and holidays selectable).· State tables: configure 20 changes of operating

modes in a door per day (switch door from lock to unlock).

· Yearly calendar: is updated every month automatically by the wireless system.

· Automatic DST: Daylight Saving Time change. Updated with calendar.

· Maintains clock/calendar for 96h without power supply (internal batttery shall be previously charged within 1 day).

· Operating modes:· Standard: Default operating mode. No

access until valid credential presented, then allows to open the door for 4-10 seconds (configurable).

· Standard ADA: Standard with double opening time.

· Passage mode: door is always in open mode (configured by time zones or by authorized user after double badging).

· Double user: Two valid credentials needed to open de door.

· First user: door in standard mode until first valid user enters, then will remain in passage mode (until closed by authorized user or automatically by time zone, state tables).

RF Module · 868MHz or 915MHz selectable in field.· 30 configurable channels:

· From 868,00 to 875,25 in steps of 0,25Mhz each channel.

· From 915,00 to 922,25 in steps of 0,25Mhz each channel.

· Auto-link with communication Hubs (easy setup).· Upgradeable firmware.

Electronic Technical Characteristics

LECTOR MURAL R4

Page 4: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

The relay board is the ideal complement for wall readers when it is necessary to manage an electrically controlled locking element from a single point, deciding for each user which elements must be activated. Encrypted communication between reader & relay board, no manipulation on the wiring between these devices can open the door. · Box & mounting:

· Relay board is supplied in a box that allows surface mounting.

· The electric board can be mounted in DIN rails (DIN rail enclosure not included). Tamper switch must be overridden or added separately.

· The two relays SMARTair™ board is a new generation product with following connections:

· Connector for reader.· Power supply connector.· Door position (sensor not included): Intrusion

or door left open will be reported. · Push Button: Request to exit.· Tamper alarm against relay board

manipulation: tamper included in the board.· 2 output relays:

· Relay 1 commands the electromechanical lock (not included).

· Relay 2 can be used for other purposes. This relay functionality is configured by software or the dip switch on the board.

· Configuration Dip switch. It can be configured from the Management Software of by this Dip.

· Other type of relay boards available for wall readers, can be acquired as spare part:

· Simple 1 relay board with reduced size.· 8 output relay board: typically used in

elevators. 5 of this elevator boards can be connected in serial (40 output relays).

Relay Board

CAJA 2 RELES

36120,5

105,5

SMARTair™ Relay Board.

Page 5: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.

www.assaabloy.com

Talleres de Escoriaza S.A.U.Barrio de ventas 3520305 IrunGipuzkoa · EspañaT: +34 943 669 100F: +34 943 633 [email protected]/smartair

TESA is the leading Spanish manufacturer and supplier of locking solutions and access control technology for the residential and institutional markets. TESA has a wide and complete range of products including panic exit devices, cylinders, security locks, knobs and handles, door closers, access control solutions with electronic cylinders, electromechanical and electromagnetic solutions and armoured doors. TESA exports to markets such as Latin America, Middle East, Europe, Asia Pacific and the North African countries.

SMARTair™ is a powerful access control system that offers an intelligent, yet simple, step up from keys. SMARTair™ is the cost-effective alternative to a full high-security system. SMARTair™ contactless, smart card technology is easily incorporated into existing systems, with multiple management solutions. No bells, whistles, or wires, just sleek, reliable security.

We

rese

rve

the

right

to m

ake

tech

nica

l mod

ifica

tions

. Ver

sion

: TES

A SM

ARTa

ir™ Te

chni

cal I

nfor

mat

ion

06 2

016

ENG

Page 6: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

An ASSA ABLOY Group brand

ABLOY® EL460, EL461, EL560, EL561Europrofile handle controlled locks

ABLOY® Europrofile locks offer intelligent solution for medium traffic doors. Locks can be installed with long plates or roses.

Europrofile handle controlled locks

ABLOY® Europrofile locks offer intelligent solution for medium traffic doors. Locks can be installed with long plates or roses.

Page 7: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

Convenience, High security, High durability - Europrofile handle controlled locks

FUNCTIONHandle controlled locks can be set to function as fail locked or as fail unlocked. In the fail locked setting, the lock can be opened by controlled handle when power is on, and it can not be opened by controlled handle, when power is off. In the fail unlocked setting, the electrical function is the opposite.

ABLOY® EL560 and ABLOY® EL460 Only outside handle is electrically controlled. The lock can always be opened by inside handle. Mechanical opening by cylinder is always possible.

ABLOY® EL561 and ABLOY® EL461Both inside and outside handles are electrically controlled. Mechanical opening by cylinder or thumbturn is always possible.

EN STANDARDSEN 179:2008 Exit EN 1125:2008 Panic exitEN 1634-1 Fire resistanceEN 61000-6-1:2007 EMCEN 61000-6-3:2007 EMCEN 12209:2004 Mechanical resistance

LOCAL STANDARDS NEN 5089:1995 SKG, mechanical strength and burglary resistance

GOST-R

STANDARDS

STANDARD DELIVERYStandard delivery includes:

- Lock case with opening direction 4 or 2,4- Fixing screws- Spindle adapters- Lock case manual

Please specify when ordering:- Lock type- Backset- Forend- Strike plate- Split spindle EA288 or EA289 (EL460 and EL560)

OPENING DIRECTIONS (HANDINGS)

ABLOY® DIN

1 Right inwards Left inwards2 Left inwards Right inwards 3 Left outwards Left outwards4 Right outwards Right outwards

4

3

2

1

APPLICATIONSThe locks are recommended to be used in the interior doors of business premises, public buildings, hospitals, educational premises etc. Typical applications are the doors of:

- Offices- Meeting rooms - Storage rooms - Technical maintenance rooms- Consulting rooms- Fire doors (medium traffic)

ABLOY® EL560 and ABLOY® EL561 are used in wooden and metal doors. ABLOY® EL460 and ABLOY® EL461 are used in narrow profile doors. EL560 or EL460 with split spindle is chosen, when exit by handle is needed. EL561 or EL461 is used, when both access and exit are electrically controlled. Handle controlled locks are best suited in medium traffic doors. The locks can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button. The locks can be used both in exit and fire rated doors (EN). The locks are not suitable for use with door automatics.

Also available:

- Microswitch locks EL360 for wooden and metal doors EL260 for narrow profile doors

- Mechanical locks EL160 for wooden and metal doors EL060 for narrow profile doors

Also available lock cases for Swiss cylinder (RZ):- EL562 (split spindle), EL563 (through spindle) for

wooden and metal doors- EL462 (split spindle), EL463 (through spindle) for narrow profile doors- EL362 microswitch lock for wooden and metal doors- EL262 microswitch lock for narrow profile doors- EL162 mechanical lock for wooden and metal doors- EL062 mechanical lock for narrow profile doors

locks can be electrically controlled by access control system or by a remote control system such as timer, keypad or push button. The locks can be used both in exit and fire rated doors (EN). The locks are not suitable for use with door automatics.

Also available:

Also available lock cases for Swiss cylinder (RZ):

Page 8: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

Max

45 Max 4

5

Max 7

Operating voltage: 12 – 24 V DC STAB (-10%, +15%)Current: Max. 0.55 A (12V DC), 0.27 A (24V DC) Idle 0.24 A (12V DC), 0.11 A (24V DC)Microswitches: Max. 0.5 A 30 V AC/DC resist, 10 WOperating temperature: -20°C - +60°CBolt throw: 20 mm (deadbolt), 10 mm (double action bolt)Backset: 55, 60, 65, 80, 100 mm (EL560, EL561) 30, 35, 40, 45 mm (EL460, EL461)Forend: 20, 24 mm (EL560, EL561) 24, 28 mm (EL460, EL461)Spindle: 9 mm (8 mm with spindle adapters)Settable functions: Mechanical functions: - Handing of trigger bolt - Electrically controlled side (EL560, EL460) Electrical function: - Fail locked / Fail unlockedMonitoring outputs: Bolt deadlocked Bolt inside the lock case Trigger bolt in Handle used Cylinder used Cable sabotage

TECHNICAL DETAILS

CONTROL PRINCIPLE AND AVAILABLE MONITORING OUTPUTS

CAM ANGLE

*) For further information, please contact Abloy Architectural Hardware.**) Handing must be defined.

DOOR ENVIRONMENT

Wooden and metal doors

Door closer

Door closer

Narrow profile doors

Leave some extra cable on both sides of the lead cover

Leave some extra cable on both sides of the lead cover

Ø 10 mm drilling for cable

Ø 15 mm pipe to lead cable inside the profile

Ø 20 mm pipes to lead cable inside the wall

Ø 20 mm pipes to lead cable inside the wall

CYLINDERS, FITTINGS AND ACCESSORIES (Please order separately)

ABLOY PROTEC

ABLOY DISKLOCK PRO

EUROPROFILE DIN CYLINDERFITTINGS

CABLESSPLIT SPINDLES

LEAD COVERS

STRIKE PLATES

SingleCY321NCY331N CY321D

Double CY322NCY332N

CY322DEA218 (6m)EA219 (10m)

EA288 (8mm)EA289 (9mm)

ABLOY®*)IKON Ruko

BEZAULT others

EA280EA281

EA321**)EA322EA323**)EA324EA325EA326EA327EA328EA329EA330EA331EA332**)

Single with thumbturn

CY323NCY333N CY323D

*) Not microswitch or mechanical locks**) Not mechanical locks

+–

12V DC (-10%) - 24V DC (+15%) STAB. *)**)

LOCKED / OPEN *)**)(POTENTIAL FREE CONTROL)

CYLINDER USEHANDLE DOWN

BOLT OUT

COMMON FOR BOLT OUT

TRIGGER BOLT IN

BOLT INCOMMON FOR BOLT IN /TRIGGER BOLT IN

SABOTAGE LOOP

MO

NIT

OR

ING

OU

TPU

TS **

)COMMON FOR HANDLE DOWN / CYLINDER USE

ABLOY NOVEL

CY321UCY331U

CY322UCY332U

CY323UCY333U

Oy

Page 9: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

ABLOYEA321

152

170

20

2 8

ABLOYEA323

232

250

202

25,1

EA321**)

EA326

EA331

EA322

EA327

EA332**)

EA323**)

EA328

EA324

EA329

EA325

EA330

**) Handing must be defined

STRIKE PLATES

Page 10: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

3530

022

10

20

6 8

10.5

20.5

9176

10.5

25

24 / 28

3

20

45 / 50 / 55 / 60

30 / 35 / 40 / 45

2521

.5

92 (P

Z) /

94 (R

Z)8.5

5.58

8

152217

4.5 x 2

8 / 9

5.5

101

1239

3032

254

EL560-MITTA-31.08.10

168.

566

.5

38

98/

38

21.5

8

R7

3

20 / 24

35

20

6

8

10

235

22

35

6 x 2

80 / 1005 / 60 / 65 /88 / 93 / 98 / 113 / 133

6 x 2

63

72 (

PZ

) /

74 (

RZ

)16.5

8

57

3515

ABLOY® EL460, EL461

ABLOY® EL560, EL561

DIMENSIONS

5

Page 11: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

Abloy OyWahlforssinkatu 20P.O.Box 108FI-80101 JOENSUUFINLANDTel. +358 20 599 2501Fax +358 20 599 2209

www.abloy.com

An ASSA ABLOY Group brand

Abloy Oy is one of the leading manufacturers of locks, locking systems and architectural hardware and the world’s leading developer of products in the field of electromechanical locking technology.

ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.

PANIC EXIT DEVICES INSTALLATION ACCORDING TO EN 1125The following locks and push bars are approved to be installed together in an panic exit door to conform EN 1125. The push bars can be installed for example with above mentioned outside fittings (Table EN 179) to conform EN 1125.

The safety features of this product are essential to its compliance with EN 1125. No modification of any kind, other than those described in the installation manual, are permitted.

EN179 and EN1125 standards are comformed, when the above mentioned lock is installed with ABLOY® strike plates listed in this brochure.

This document may not be used in the installation of a lock. Drilling and wiring diagrams and installation instructions are included in the installation manual, which is included in each lock case package.

We reserve the right to make alterations to the products described in this leaflet.

EMERGENCY EXIT DEVICES ACCORDING TO EN 179The following locks and handles are approved to be installed together in an emergency exit door to conform EN 179.

The safety features of this product are essential to its compliance with EN 179. No modification of any kind, other than those described in the installation manual, are permitted.

Profile door locks

EL460

EL260EL060

Wooden and metaldoor locks

EL560

EL360EL160

IKONDO 20.15.02

e.g. S6B3, S6B6

e.g. S6B8

IKONDO 20.15.02

e.g. S326, S426, S4K3

e.g. S4K6

FSBDO 20.03.01, DO 20.03.02

1016, 1023, 1056, 1070, 1080, 1088, 1090, 1117, 1118, 1119, 1137, 1146, 1155, 1160, 1161, 1162, 1177, 1178, 1191, 0612,0616, 0617, 0619, 0625, 0627, 0628, 0646, 0662, 0665, 0680, 0681, 0682, 0688

HEWIDO 20.13.01, DO 20.13.02

111, 111.23, 114.23GK, 131, 132, 111X, 113X, 114X, 161X, 163X, 171X, 112X, 165X, 166X

HEWIDO 30.10

SAPEXDO 20.32.01DO 20.32.02

e.g. 60-00819

SAPEXDO 20.32.01DO 20.32.02

e.g. 60-0419, 60-0319

ABLOY®

DO 20.33.01DO 20.33.02

e.g. ABLOY® INOXI 3-19/013

PZ+BL

ABLOY® INOXI 3-19/013/120 PZ+BL

ABLOY®

DO 20.33.01DO 20.33.02

e.g. ABLOY® INOXI 3-19/012

PZ+BL

ABLOY® INOXI 3-19/012/120 PZ+BL

Profile door locks

EL460, EL260, EL060

EL462, EL262, EL062

Wooden and metaldoor locks

EL560, EL360, EL160

EL562, EL362, EL162

effeffDO 30.04

8000-00-1100 (-), 8000-10-1100 (PZ)

8000-00-1100 (-), 8000-11-1100 (RZ)

effeffDO 30.04

8000-00-1100 (-), 8000-20-1100 (PZ)

8000-00-1100 (-), 8000-21-1100 (RZ)

JPMDO 30.05

NORMA 990000-XX-0A990100-XX-0A990001-XX-0A990101-XX-0A991000-XX-0A991100-XX-0A991001-XX-0A991101-XX-0A

TESADO 30.06

TESADO 30.06

8801

046

2/2

011

200

0 kp

l S

uom

en P

aino

tuot

e, J

oens

uu

UNIVERSAL SERIE19709G9xx

HEWI PS 160XA 400

Page 12: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

42 TESA catalogue | Cylinders

High security cylinder TX80

» Type: Patented dimple key with security sensor.

» NO. of rows: 2

» NO. of pins: 8

» Technology: Tumbler regular.

» Permutation level: Grade 6.

» Corrosion resistance: Grade B

» Anti pick cylinder lock (High resistance.)

» Bump proof system.

» Drill protection grade 2.

» Lifespan: 100,000 test cycles.

» Key copies protected with security card.

» Clutch of double security.

» 5 patented keys made of nickel silver.

» Conform to EN-1303 regulation.

» Master key systems: High capability using side pins and multi

profile key ways.

Options

» Finishes: Brass / Nickel.

» Cam: DIN R15 and R13.

» Formats available: Key different, mater keyed, key alike and

specific codes.

» Wide measurement and profile range.

» Colour points to differentiate master key levels.

Master key systems

The patented character of the system will let the owner control,

in every moment, the key copies thanks to the property card

provided with each cylinder or master key suite.

Tx80 cylinders have been designed according to the highest

quality protection systems. It is a model in constant evolution

that incorporates the most advanced security developments

(bumping, picking…etc). A design thought to offer to the user

the higher security grade in all its extension.

Technical data

Characteristics

Security Masterkeying

In the same way as the main models included in the catalogue,

TX80 is certified according to the European standard regulation.

European standard regulation

» Use TESA lubricant to lengthen the maximum lifespan of the

cylinder.

» TESA recomends to the user of the TX80 to keep the property

card in a safe and secure location. Only by presenting this card,

can one obtain key and cylinder copies.

» For safety reasons, when you install a new cylinder, remember

that once installed, it should not project more than 1mm.

Recommendations

1 6 0 1 0 B 6 0

Key re

sistan

ce

(Grade 0-1

)

Lifesp

an(G

rade 4-6

)

Door m

ass

(Not ap

plie

d in

cylinder)

Fire

resistan

ce(G

rade 0-1

)

Safety of the people

(Not ap

plie

d in

cyliders)

Corrosion and tem

peratu

re

resistan

ce(G

rade 0-A

-B-C

)

Key re

late

d secu

rity

(Grade 1 to 6)

Attac

k re

sistan

ce(G

rade 0 to 2)

*Note; with the shield E700 the attack resistance rise to the level 2.

Page 13: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

D

Cylinders | TESA catalogue 43

High security cylinder TX80

Double european. L A B Cam = 15 mm Finish Cam = 15 mm Finish

60 30 30 TX85 30 30 L Brass TX85 30 30 N Nickel

65 30 35 TX85 30 35 L Brass TX85 30 35 N Nickel

70 30 40 TX85 30 40 L Brass TX85 30 40 N Nickel

70 35 35 TX85 35 35 L Brass TX85 35 35 N Nickel

75 30 45 TX85 30 45 L Brass TX85 30 45 N Nickel

75 35 40 TX85 35 40 L Brass TX85 35 40 N Nickel

80 30 50 TX85 30 50 L Brass TX85 30 50 N Nickel

80 35 45 TX85 35 45 L Brass TX85 35 45 N Nickel

80 40 40 TX85 40 40 L Brass TX85 40 40 N Nickel

85 35 50 TX85 35 50 L Brass TX85 35 50 N Nickel

90 30 60 TX85 30 60 L Brass TX85 30 60 N Nickel

90 35 55 TX85 35 55 L Brass TX85 35 55 N Nickel

90 40 50 TX85 40 50 L Brass TX85 40 50 N Nickel

90 45 45 TX85 45 45 L Brass TX85 45 45 N Nickel

100 30 70 TX85 30 70 L Brass TX85 30 70 N Nickel

100 40 60 TX85 40 60 L Brass TX85 40 60 N Nickel

100 50 50 TX85 50 50 L Brass TX85 50 50 N Nickel

110 30 80 TX85 30 80 L Brass TX85 30 80 N Nickel

110 50 60 TX85 50 60 L Brass TX85 50 60 N Nickel

120 30 90 TX85 30 90 L Brass TX85 30 90 N Nickel

120 40 80 TX85 40 80 L Brass TX85 40 80 N Nickel

120 60 60 TX85 60 60 L Brass TX85 60 60 N Nickel

130 30 100 TX85 31 00 L Brass TX85 31 00 N Nickel

140 40 100 TX85 41 00 L Brass TX85 41 00 N Nickel

150 50 100 TX85 51 00 L Brass TX85 51 00 N Nickel

160 60 100 TX85 61 00 L Brass TX85 61 00 N Nickel

Single european L A B Cam = 15 mm Finish Cam = 15 mm Finish

40 30 10 TX85 30 10 L Brass TX85 30 10 N Nickel

45 35 10 TX85 35 10 L Brass TX85 35 10 N Nickel

50 40 10 TX85 40 10 L Brass TX85 40 10 N Nickel

60 50 10 TX85 50 10 L Brass TX85 50 10 N Nickel

70 60 10 TX85 60 10 L Brass TX85 60 10 N Nickel

80 70 10 TX85 70 10 L Brass TX85 70 10 N Nickel

90 80 10 TX85 80 10 L Brass TX85 80 10 N Nickel

100 90 10 TX85 90 10 L Brass TX85 90 10 N Nickel

Knob european L A B Cam = 15 mm Finish Cam = 15 mm Finish

60 30 30 TX8B 30 30 L Brass TX8B 30 30 N Nickel

65 30 35 TX8B 30 35 L Brass TX8B 30 35 N Nickel

70 35 35 TX8B 35 35 L Brass TX8B 35 35 N Nickel

70 40 30 TX8B 40 30 L Brass TX8B 40 30 N Nickel

80 30 50 TX8B 30 50 L Brass TX8B 30 50 N Nickel

80 40 40 TX8B 40 40 L Brass TX8B 40 40 N Nickel

85 35 50 TX8B 35 50 L Brass TX8B 35 50 N Nickel

90 30 30 TX8BTB3030L Latón TX8BTB3030N Níquel

90 35 30 TX8BTB3530L Latón TX8BTB3530N Níquel

European with assistant function L A B Cam = 15 mm Finish Cam = 15 mm Finish

60 30 30 TX85 30 30 LLIM Brass TX85 30 30 NLIM Nickel

70 30 40 TX85 30 40 LLIM Brass TX85 30 40 NLIM Nickel

70 35 35 TX85 35 35 LLIM Brass TX85 35 35 NLIM Nickel

80 40 40 TX85 40 40 LLIM Brass TX85 40 40 NLIM Nickel

90 40 50 TX85 40 50 LLIM Brass TX85 40 50 NLIM Nickel

90 45 45 TX85 45 45 LLIM Brass TX85 45 45 NLIM Nickel

European profile

Patented

12 units.

These cylinders are provided with 4 owner keys and one for the assistant.

Both side A and B includes the function.

* To process “master keyed” and “cylinders alike” orders add either AM or KA in each part number, respectively.

** The butler system lets operate with the key from the outside even if knob is blocked. Is a solution thought for schools, geriatrics..

etc.

SYST EM* *

BUTL ER

BT

A B

L

10 AL

A B

L

L

A B

Page 14: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

22 TESA catalogue | Handles

Institutional stainless AISI 316L handle

Sena AISI 316LThe pack with a rosette includes

» A set of handles with an internal plate and a cover, 1 8x105

mm spindle, 2 recoil springs, 4 coach screws, 2 bolts and an

Allen key.

The pack with a long plate includes

» A set of handles with an internal plate and a cover, a 8x105

mm spindle, 2 recoil springs, 4 coach screws, 2 bolts and an

Allen key.

» Rectangular plate also available

The pack with a squared plate includes

» A set of handles with a 1’5 mm-thick internal plate and a

cover, a 8x105 mm spindle, 2 recoil springs, 5 floating through

bolts, 5 screws, 2 bolts and an Allen key.

Functions

» Entrance: keyhole at 85, 72, 70 and 47 mm.

» Privacy: deadbolt at 85, 72, 70 and 47 mm.

» Passage.

Rosette Product code Finishes

Rosette MS5R800 IS16 (includes through bolts)

Rosette MMTFR800 IS16 1/2 Fixed knob + CUADRAE

Rosette MSTFR800IS16 1/2 Fixed knob + CUADRAE

+ 1/2 Sena

Rosette MTF5R800IS16 Double Fixed knob

+ 2 CUADRAE

Long plate Product code Finishes

Passage MS5L800 IS16 (no through bolts included)

Rectangular MS5LR800 IS16 (no through bolts included)

Cylinder at 47 mm MS0L847 IS16 (no through bolts included)

Cylinder at 70 mm MS0L870 IS16 (no through bolts included)

Cylinder at 72 mm MS0L872 IS16 (no through bolts included)

Cylinder at 85 mm MS0L885 IS16 (no through bolts included)

Deadbolt at 47 mm MSEL847 IS16 (no through bolts included)

Deadbolt at 70 mm MSEL870 IS16 (no through bolts included)

Deadbolt at72 mm MSEL872 IS16 (no through bolts included)

Deadbolt at 85 mm MSEL885 IS16 (no through bolts included)

Square plate Product code Finishes

Pasagge MS5C800 IS16 (includes through bolts)

Cylinder at 47 mm MS0C847 IS16 (includes through bolts)

Cylinder at 70 mm MS0C870 IS16 (includes through bolts)

Cylinder at 72 mm MS0C872 IS16 (includes through bolts)

Cylinder at 85 mm MS0C885 IS16 (includes through bolts)

Deadbolt at 47 mm MS3C847 IS16 (includes through bolts)

Deadbolt at 70 mm MS3C870 IS16 (includes through bolts)

Deadbolt at 72 mm MS3C872 IS16 (includes through bolts)

Deadbolt at 85 mm MS3C885 IS16 (includes through bolts)

215

45 8

62

55

135

180 1,5

Page 15: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

G

Handles | TESA catalogue 31

Institutional stainless AISI 316L handlecomplements

Key holes

Blank

The pack includes:

» A set with support pieces and

covers.

» 4 coach screws.

Finish

» IS16

The pack includes:

» A set with support pieces and

covers.

» 4 coach screws.

Finish

» IS16

Product code Finish

MB0RBOM IS16

Product code Finish

MB0R000 IS16

Thumb turnsThe pack includes:

» A set with support pieces and

covers.

» 4 coach screws.

Finish

» IS16

Product code Finish

MB0REME IS16

Page 16: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

76 Door closers

Cam-Motion® guide rail system

DC500

88,5 23,5 100

270

485

505

43

38

10

3

57

64

39 ( 32)

23

(20

,5)

ASSA ABLOY DC500

· Door closer with Cam-Motion® technology and

height-adjustable guide rail G195 or standard guide

rail G193

· Fulfils barrier-free building requirements (DDA / CEN

TR 15894)

· Certified in compliance with EN 1154, size 1-4

· Suitable for fire and smoke protection doors

· For single action doors up to 1100 mm wide

· Can be used in four installation types: hinge and

non-hinge sides in standard and frame installation

Characteristics DC500

· Can be used with integrated concealed mounting

plate, suitable for fire and smoke protection doors

· Can be used for left and right-handed doors

· Axis continuously height adjustable up to 14 mm

· Closing speed, latching speed and backcheck adjus-

table via front facing regulating valves

· Thermodynamic valves for consistent performance

· Variable adjustable closing force

· Opening angle up to 170°

· Effective backcheck and latching speed range adjus-

table

· Large range of applications

· Standard colours: silver EV1; white, similar to

RAL9016; brown, similar to RAL8014; black, similar

to RAL9005, stainless steel

· Customised finishes available on request

Characteristics for guide rail G195

· Height-adjustable by 2 mm for tolerance

· Concealed fastening screws

· Installation dimensions: see diagram

Characteristics of standard guide rail G193

· Without protective cover

· Visible fastening screws

· Installation dimensions: see diagram (dimensions in

brackets)

13

8 41 1

13 41162-CPD-0629 EN 1154:1996+A1:2002

Abloy OYPO Box 10880101 Joensuu,Finland

Door closer with Cam-Motion® technology and guide

rail

Page 17: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

77 Door closers

Cam-Motion® guide rail system

DC500

Project planners - Extensive range of uses: Fire and smoke protection doors as well as standard doors- Modern design- Compact design- Fulfils barrier-free building requirements (DDA / CEN TR 15894)- Same dimensions and design with and without mounting plate

Builders - One drilling template overall- Adjustable to nearly all door and frame types- Quick and easy installation- Quickly and easily adjustable- Suitable for left and right handed doors for standard and frame mounting on hinge and non-hinge side

Trade - Reduced inventory costs due to modular product range- One single product suitable for a large variety of mounting positions- Complementary accessories available for the whole product range

User - Largely unaffected by temperature fluctuations thanks to thermodynamic valves- Easier door opening and improved accessibility due to reapidly decreasing torque

Our service for you: here

you can see the indivi-

dual advantages of our

door closer models for

your respective field of

business.

You can find the

complete specifica-

tions on the Internet

at: www.assaabloy.de,

under „Service“ in the

support section.

The advantages at a glance

Technical attributes

Customer segment Advantages

Specifications for DC500

ASSA ABLOY Door Closer DC500 with Cam-Motion®

technology and guide rail in compliance with EN 1154

· Closing power continuously adjustable, EN size 1-4,

for doors up to 1100 mm wide

· Closing speed, latching speed and backcheck conti-

nuously adjustable

· Can be used with integrated concealed mounting

plate, suitable for fire and smoke protection doors

· CE approved

· 14 mm height adjustable arm system for ease of

fitting

· Standard and frame mounting on hinge and non-

hinge side of the door

· Suitable for left and right handed doors

Accessories:

Standard guide rail

G193

Height-adjustable gui-

de rail G195

Mounting plate A120

Mounting plate A130

for guide rail G193

and G195

Angle bracket A104

for guide rail G193

Mechanical opening

damper A153

Mechanical hold-open

device A152 (not for

fire and smoke pro-

tection doors)

Glass door shoe A166

Colour:

Silver EV1

White, similar to

RAL9016

Brown, similar to

RAL8014

Black, similar to

RAL9005

Stainless steel

Customised finish

Variable adjustable closing force EN 1-4

Door width up to 1100 mm

Fire and smoke protection yes

DIN door swing directions left / right handed

Standard and frame installation yes

Closing speed Variable between 170°-10°

Latching speed Variable between 10°-0°

Backcheck Variable above 75°

Opening angle hinge side ca. 170°

Opening angle non-hinge side ca. 120°

Weight 2.7 kg

Height 64 mm

Depth 57 mm

Width 270 mm

Certified in compliance with EN 1154

CE marking for building products yes

Technical attributes

Page 18: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

78 Door closers

Cam-Motion® guide rail system

DC500

Dimensional drawings

371,5

605

10

3

68

,5

Space required on doors

for standard installation

on hinge side

Left handed shown in diagramRight handed is the re-verse

13max.

15

43

38

213,5

43

485110

100

15

38

Installation dimensions

for direct standard

mounting on hinge side

Left handed shown in diagramRight handed is the re-verse

110 485

142 160

16

4265

Installation dimensions

with mounting plate for

standard mounting on

hinge side

In compliance with EN 1154, Supplement 1, or for doors where direct mounting is not possible. Left handed shown in diagramRight handed is the re-verse

43

485110

100

11

38

213,5Installation dimensions

for direct frame moun-

ting on hinge side

Closer on hinge side of door frame.Left handed shown in diagramRight handed is the re-verse

110 485

142 160

65

16

11

Installation dimensions

with mounting plate for

frame mounting on hinge

side

Closer on hinge side of door frame. For doors where direct mounting is not possible.Left handed shown in diagramRight handed is the re-verse

Page 19: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

79 Door closers

Cam-Motion® guide rail system

DC500

Dimensional drawings

110 485

100176,5

113

8

43

Installation dimensions

for direct standard

mounting non hinge side

Right handed door

shown in diagram

Left handed door is the

reverse

16

105 160

110 485

1165

Installation dimensions

with mounting plate for

standard mounting non

hinge side

For doors where direct

mounting is not possible

Right handed door

shown in diagram

Left handed door is the

reverse

110 485

100

43

213,5

1538

Installation dimensions

when mounted directly

onto the frame non-

hinge side

Closer on non-hinge side

of door frame

Right handed door

shown in diagram

Left handed door is the

reverse

16 42

142 160

65

110 485

Installation dimensions

with mounting plate for

frame mounting non-

hinge side

Closer on non-hinge side

of door frame. For doors

where direct mounting is

not possible.

Right handed door

shown in diagram

Left handed door is the

reverse

Page 20: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

80 Door closers

Cam-Motion® guide rail system

DC500

Accessories

ISO 15065-5

7

6,5

16

33

,51

6183

56

160

Mounting plate A120

For mounting with dril-

ling template acc. to EN

1154 Supplement 1 and

for universal use

42

16

65

10

505

485

71

3

30

Mounting plate A130

For guide rail G193 and

G195

42

16

52

71

3

65

( )

10 485

505

242,5 242,5

15

23

9

Angle bracket A104

Only for standard guide

rail G193

65

8

15

23

81

16

R4

A

A

16020,8

210

6,5

33

,5 16

16

56

Replacement plate A124

For renovation applica-

tions

Ø

Ø

6,5

90

°

11

4

A-A

270

67

Glass door shoe A166

For mounting the door

closer on the all-glass

door leaf.

10max.

Page 21: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

81 Door closers

Cam-Motion® guide rail system

DC500

Accessories and order placement information

Stainless steel full cover

For DC500 and DC700

Stainless steel design cover

For DC500 and DC700

Hold-open device A152

Mechanical hold-open device for doors which sometimes need to be secured in the

open position.

Simple fitting into guide rail G193 and G195.

Hold-open angle max. 130°

Adjustable hold-open force

Not approved for use on fire and smoke protection doors.

Opening damper A153

Helps to prevent the door and door handle from hitting a return wall.

Simple fitting into guide rail.

Opening damper continuously adjustable up to an opening angle of max. 130°.

Does not replace a door stop.

Description Order no.

DC500, EN size 1-4, silver EV1

DC500, EN size 1-4, white, similar to RAL9016

DC500, EN size 1-4, brown, similar to RAL8014

DC500, EN size 1-4, black, similar to RAL9005

DC500, EN size 1-4, stainless steel, ASSA ABLOY design

DC500, EN size 1-4, stainless steel full cover

DC500, EN size 1-4, customised finish

Guide rail G193, silver EV1

Guide rail G193, white, similar to RAL9016

Guide rail G193, brown, similar to RAL8014

Guide rail G193, black, similar to RAL9005

Guide rail G195, silver EV1

Guide rail G195, white, similar to RAL9016

Guide rail G195, brown, similar to RAL8014

Guide rail G195, black, similar to RAL9005

Guide rail G195, stainless steel

Description Order no.

Guide rail G195, bespoke finish

Mounting plate A120, galvanised

Replacement�plate�A124,�galvanised

Mounting plate A130, silver EV1

Mounting plate A130, white, similar to RAL9016

Mounting plate A130, brown, similar to RAL8014

Mounting plate A130, black, similar to RAL9005

Mounting plate A130, customised finish

Mounting plate A136, non-hinge�side,�for�Gui-de�Rail�G193�and�G195,�40�mm,�silver�EV1

Glass door shoe A166, silver EV1

Angle bracket A104, silver EV1

Angle bracket A104, RAL9016 white

Angle bracket A104, brown, similar to RAL8014

Angle bracket A104, black, similar to RAL9005

Hold-open device A152

Opening damper A153

Page 22: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

42 TESA catalogue | Handles

Accessories - Institutional stainless AISI 304Stopper

The pack includes:

» Rubber plug with fixing screws.

Finish

» IS304

The pack includes:

» Rubber plug with fixing screws.

Finish

» IS304

The pack includes:

» Rubber plug with fixing screws.

Finish

» IS304

The pack includes:

» Rubber plug with fixing screws.

Finish

» IS304

Product code Finishes

TOPINOX45IS IS-

Product code Finishes

TOPINOX4320IS IS-

Product code Finishes

TOPERCHAIS IS-

Product code Finishes

TOPINOXRIS IS-

Half-dome door stopper ø45

Wall door stopper Coath hook w/ rubber buffer

Full-dome door stopper

30

45

30

615

16

46 19

84

7

11

66

6

20

9.1X 90°

19

50

24

13.7

20

35

16

3.0

68 9

Page 23: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

ASSA ABLOY, the global leader in door opening solutions

Communication HubPro Wireless Online

· Communication hubs are the nexus between the management software server and the Pro Wireless Online devices, which allows:

· Automatic access plan modifications.· Real- time audit trail.· Inmediate cancellation of lost credentials.· Remote opening.

· Bi-directional communication allows for direct control of doors, and active warnings with maximum flexibility.

· SMARTair™ Hubs do not require their own wiring as they are connected to the existing TCP/IP network.

· PoE connection allows the Hubs to be powered directly from the communications network.

· Each Hub can manage up to 30 access points (doors, barriers, lifts, etc.) at a distance of 30m, which again positively impacts the cost effectiveness of the system.

· Certificates: · CE (EMC, R&TTE).· ROHS, REACH, WEE.

140

120

60

59.9970

164.9

144.9

36

Page 24: TESA ASSA ABLOY Tel: +34 91 6785565 · EN 1125:2008 Panic exit EN 1634-1 Fire resistance EN 61000-6-1:2007 EMC EN 61000-6-3:2007 EMC EN 12209:2004 Mechanical resistance LOCAL STANDARDS

Electronic Technical Features Installation recommendationMain control· Encrypted wireless radio frequency

communication.· Secure end-to-end encryption:

· TCP/IP SSL encrypted communication between server & communication Hubs.

· 868 MHz or 915 MHz radio communication with door devices, with AES128 encryption.

· Power, 2 ways:· 12-24 DC: max consumption 1A @12DC (0,5A

@24 VDC).· PoE: directly from the network cable (switches

must also be PoE). IEEE802.3af compliant.· Ethernet communication: RJ45 connector for TCP/

IP. UTP CAT5 cable recommended. · Upgradeable firmware.· Non-volatile event memory· Autolink of wireless devices with the Hub to allow

a quick and easy set up· Manual link that allows to assign and/or reassign

wireless devices to the various Hubs with no need of being physically at the door.

RF module· 868MHz or 915MHz selectable in field.· 30 configurable channels:

· From 868,00 to 875,25 in steps of 0,25Mhz each channel.

· From 915,00 to 922,25 in steps of 0,25Mhz each channel.

Mechanical Technical features· ABS plastic.· RAL 7035· Dimensiones: 144,9 (L) x 164,9 (W) x 36 (D) mm.

Environmental performance· Hubs shall be installed in the inside part of the

building. · Temperature range: 0ºC - 60°C.· Humidity: 10-90%. Vapour and humidity may

affect wireless signal.

Recommended Communication Hub position The following picture shows the recommended location where the SMARTair™ communication Hub should be installed. It should be on the wall, halfway up the ground in a vertical position, and the RF module (antenna) oriented in horizontal.

Other recommendations to install the Communication Hub correctly:· Do not install a Hub in outer walls. · Do not install a Hub near metallic elements, such

as grids or structure cables.· Avoid any mirrors between the Hubs and the

wireless devices. Mirrors reflect the signal and do not cross them.

· Avoid installing Hubs where there is a possibility to have more than two walls between it and the wireless devices to communicate with.

· Avoid having microwaves within a distance of 5 meters to the Hub.

· When installing a Hub consider the RF modules of the devices are in the inside part of the door and in the wall readers these are in the outside part.

· Do not install any Hub in metallic doors when possible.

Antenna