10
1 Terrain Amplification of Wind Loads in Northern Guam Terrain Amplification of Wind Loads in Northern Guam 2010 NAVFAC Pacific/Hawaii Designer & Builder Symposium Wednesday, 1 December, 2010 Hilton Hawaiian Village-Coral Ballroom

Terrain Amplification of Wind Loads in Northern Guam · 2018-04-03 · UFC 3-310-04 Seismic Design for Buildings – 22 Jun ‘07, with Change 1 – 27 Jan ’10 – Based on IBC

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Terrain Amplification of Wind Loads in Northern Guam · 2018-04-03 · UFC 3-310-04 Seismic Design for Buildings – 22 Jun ‘07, with Change 1 – 27 Jan ’10 – Based on IBC

1 Terrain Amplification of Wind Loads in Northern Guam

Terrain Amplification of Wind Loads in Northern Guam

2010 NAVFAC Pacific/HawaiiDesigner & Builder Symposium

Wednesday, 1 December, 2010Hilton Hawaiian Village-Coral Ballroom

Page 2: Terrain Amplification of Wind Loads in Northern Guam · 2018-04-03 · UFC 3-310-04 Seismic Design for Buildings – 22 Jun ‘07, with Change 1 – 27 Jan ’10 – Based on IBC

2 Terrain Amplification of Wind Loads in Northern Guam

Structural Criteria Update•UFC 1-200-01 General Building Requirements

–16 Aug ‘10–Adopts IBC 2009 and ASCE 7-05

•UFC 3-301-01 Structural Engineering–27 Jan ‘10, with Change 1 – 20 Jul ’10–Based on IBC 2006 and ASCE 7-05

•UFC 3-310-04 Seismic Design for Buildings–22 Jun ‘07, with Change 1 – 27 Jan ’10–Based on IBC 2003 and ASCE 7-02

Page 3: Terrain Amplification of Wind Loads in Northern Guam · 2018-04-03 · UFC 3-310-04 Seismic Design for Buildings – 22 Jun ‘07, with Change 1 – 27 Jan ’10 – Based on IBC

3 Terrain Amplification of Wind Loads in Northern Guam

Wind Design Criteria•170 mph Basic Wind Speed

•Exposure C (per IBC 2009, ASCE 7-05)

•Occupancy Categories & Importance Factors per UFC 3-301-01 Structural Engineering

So What’s Unique about Northern Guam?

TERRAIN AMPLIFICATIONof WIND LOADS

Page 4: Terrain Amplification of Wind Loads in Northern Guam · 2018-04-03 · UFC 3-310-04 Seismic Design for Buildings – 22 Jun ‘07, with Change 1 – 27 Jan ’10 – Based on IBC

4 Terrain Amplification of Wind Loads in Northern Guam

Terrain Can Affect Wind Speed

Page 5: Terrain Amplification of Wind Loads in Northern Guam · 2018-04-03 · UFC 3-310-04 Seismic Design for Buildings – 22 Jun ‘07, with Change 1 – 27 Jan ’10 – Based on IBC

5 Terrain Amplification of Wind Loads in Northern Guam

Crest of Cliff-line 300 ft high (west)to almost 600 ft high (east)

Finegayan

North Ramp

Andersen South

½ mile to 1 mile zoneWind loads up-to-doublebaseline Guam conditions

Northern Guam Wind Terrain Amplification

Page 6: Terrain Amplification of Wind Loads in Northern Guam · 2018-04-03 · UFC 3-310-04 Seismic Design for Buildings – 22 Jun ‘07, with Change 1 – 27 Jan ’10 – Based on IBC

6 Terrain Amplification of Wind Loads in Northern Guam

FinegayanTerrain Effects

12/14/2010

Crest of cliff-line

Shoreline

Route 3

Page 7: Terrain Amplification of Wind Loads in Northern Guam · 2018-04-03 · UFC 3-310-04 Seismic Design for Buildings – 22 Jun ‘07, with Change 1 – 27 Jan ’10 – Based on IBC

7 Terrain Amplification of Wind Loads in Northern Guam

Finegayan Cliff-line

12/14/2010

Page 8: Terrain Amplification of Wind Loads in Northern Guam · 2018-04-03 · UFC 3-310-04 Seismic Design for Buildings – 22 Jun ‘07, with Change 1 – 27 Jan ’10 – Based on IBC

8 Terrain Amplification of Wind Loads in Northern Guam

Terrain-amplified Wind Impacts

•Relatively small impact to Building “Shell.”

–Reinforced Concrete Systems usually governed by seismic.

–Some impact to precast/prestressed roof systems.

–Some impact to exterior walls that span high floor-to-floor heights.

•Potential Impact to Components and Cladding (i.e. window, roofing materials, etc.)

Page 9: Terrain Amplification of Wind Loads in Northern Guam · 2018-04-03 · UFC 3-310-04 Seismic Design for Buildings – 22 Jun ‘07, with Change 1 – 27 Jan ’10 – Based on IBC

9 Terrain Amplification of Wind Loads in Northern Guam

Components & Cladding Wind Loads

Wind Pressures (psf) for various building surfaces

Page 10: Terrain Amplification of Wind Loads in Northern Guam · 2018-04-03 · UFC 3-310-04 Seismic Design for Buildings – 22 Jun ‘07, with Change 1 – 27 Jan ’10 – Based on IBC

10 Terrain Amplification of Wind Loads in Northern Guam

Way Ahead• Are products commercially available

that meet terrain amplified wind loads requirements?

• What are the BEST commercially available products?

• Are customized products cost effective?

• What are the risks?