University of Illinois Participating members: D. Errede Z. Conway M. Haney G. Qian J. Crnkovic D. Errede/UIUC Absorber Group Meeting 5/17/2004 Temperature Sensor Experiment

Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

University of Illinois

Participating members:D. ErredeZ. ConwayM. HaneyG. QianJ. Crnkovic

D. Errede/UIUCAbsorber Group Meeting5/17/2004

Temperature Sensor Experiment

Page 2: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

PurposeProviding temperature information for cooling channel energy absorber undergoing testing in Mucool Test Area

Study properties of fiberoptic gauges at cryogenic temperatures.

HistoryZ. Conway, M. Haney, (D. Errede) got the experiment going, purchasing equipment, setting up cryostat, installing sensors.

Zack wrote the daq for our test setup and absorber testing in situ.

Jason Crnkovic, D. Errede, M. Haney studied the systematic errors associated with the test setup.

Gefei Qian has added some nice modifications to the daq and written a temperature conversion program whose algorithm looks better than Lakeshores.

Page 3: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Cooling Channel Lattice CellIncludes UIUC

Page 4: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

New MUCOOL Test Facility

Fill & test absorbersHP 201 MHz (& 805 MHz ?) TestsIntegrate components into a unitTest in intense ionizing beam

Page 5: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Absorber InstrumentationThe absorber environment:

-The absorber will absorb 100-1000 Watts dependingon beam intensity in cooling channel muon beam.

-The MTA will provide a 400 MeV proton beam of ~1012-1013 protons/pulse @ 15 Hz to mimic the dE/dxdeposition of a muon beam.

-The absorber sits inside a solenoid of 4 Tesla (~1.5 T atabsorber in cooling channel design)

- The absorber is filled with liquid hydrogen thus operates at cryogenic temperature (14 –20K)

THUS the monitoring devices must be rad-hard, and able tooperate in high magnetic fields and cryogenic temps.

Page 6: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Absorber Aluminum Window Pressure/Burst Testing

Page 7: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Cryogenic Testing of Temperature Gauges

Jason Crnkovic2003 Summer REU Student at UIUC

8/8/2003

Page 8: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Figure 1: The apparatus

4 windows

Liquid helium

218: sensor monitor OR

Keithley multimeter

332: cryostat temperature controller

KeithleySwitch

amphenol connector:braid-shielded cable experiment’s sample cernox RTD: to 218 channels 1-4(using channels 1 and 2 ) through the Keithley sxitch

amphenol connector;3 twisted pairs: sample heater (+-X) not connected at the moment

“ diode sense (+-V)“ diode excite (+-I)

to 332 Input Bbanana clips

amphenol connector;3 twisted pairs: vapor heater (+-X)“ diode sense (+-V)“ diode excite (+-I)

to 332 Input Abanana clips

amp connectors to allow connectionthrough the Keithley switch.

amp connectors

amp connector: connects to 218channels 5,6,7,8 ;

amphenol connectorpt06A-12-10S (sr)0238

to Edwards vacuum pump

pressuregauge then valve (gas release)

Page 9: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Sensors under consideration

FISO Temperature Gauge

Cernox

Diode

Diagram found at:http://www.lakeshore.com/temp/sen/F017_00_00.pdf

Diagram found at:http://www.lakeshore.com/temp/sen/F031_00_00.pdf

Diagram found at:http://www.fiso.com/pdf.php?id=66

Page 10: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Temperature diode and resistive transducers (experiment in Urbana)

Page 11: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Figure 2: Electronic Connections

Keithley

switch 218

IEEE-488 Interface

amp

amp 5-8 channels

1-4 channels,experimentsample RTD

332

IEEE-488 Interface

Input

B

Input

A

amp

Amphenol pt06A-12-10S(sr) 0238

navy green connectorunconnected at the moment

to PC

to PC

2x amp connectors

braided shielded cable

3 twisted pairsvapor heater +-X

“ diode sense +-V“ diode excite +-I

3 twisted pairssample heater +-X

“ diode sense +-V“ diode excite +-I

3 amphenol connectors

heater outputlowhi

vapor heater

sample heaterunconnected

2 twisted pairsvapor diode excite

sense

2 twisted pairssample diode excite

sense

Page 12: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Picture of daq screen.

Page 13: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

precision 0.01% 1000 Ohm resistor

Cu clampcovering cernox RTD

2 pairs per device

2 connections per device

2 wires per connection I in,V in or I out, V out

3 twisted pairs+-I sample 332 diode+-V “ “ “+-X “ “ heater

4 twisted pairs +-I sample 218 cernox RTD | 1st pair +-V “ “ “ | 2nd pair

| 3rd pair| 4th pair

for 2 sensors (experiment)2 twisted pairs to sample diode

Cu core for sample heater

1 twisted pair to sample heater

Cu

brass

Figure 3: Sample Holder

Page 14: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Figure 4: Sensor Circuit Diagram

Rwire ~ 15 Ohms/m, length/wire about ½ meter

Rwire

I = 10.0001 +- 0.0001 µAmps

ε

I V

Rwire

Rwire

Rwire

I - ε Z = 10 GOhms

Page 15: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Figure 5: Sensor Circuit DiagramRwire ~ 15 Ohms/m, length/wire about ½ meter

I = 10.0001 +- 0.0001 µAmps

connectors with contact potentials + thermal potentials at Janisconnectors with contact potentials + thermal potentials at 218/Keithley

connectors with contact potentials + thermal potentials at 218(the two connectors depicted on the 218 are actually one connector)

Rwire

I - ε

Z = 10 GOhms

V I

Janis

218 monitor

Keithley Switch

Rwire

Page 16: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

TestWe examined the voltages and resistances of all loops in the circuit, both as 4 wire and 2-wire resistance measurements, with the sensors in and out of thecircuit. We reversed the current through the loops to look for current-direction independent potentials.

ε

I V

Rwire

Rwire

Rwire

I - ε

I

Rwire

Keithley

The temperature dependent potentials increase with an increase in temperature.

No significant effects were found under stable temperature conditions.

Page 17: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Cernox 21265 and 27990 Resistance vs. Temperature

59.1

468.7

322.9336.5

166.91

60.23

597.5

400.4418.65

196.51

0

100

200

300

400

500

600

700

0 50 100 150 200 250 300 350

Temperature (K)

Res

ista

nce

(Ohm

s)

Cernox 21265Cernox 27990Temperature Sample Chamber

Data from Teststand using Cernox RTDs

Page 18: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Status

The status of the commissioning of the Cernox is that the calibrated sensors work (+- 0.03K @ 20K) better than the specifications of our needs (+- 0.1K @ 20K).

The electronics (Lakeshore 218s) are not measuring resistances to within specifications (worse than 1% in the 100-1000 Ohm range). The Keithley multimeter (6 ½ digit precision, accurancy tested with high precision resistors; 100 & 1000 Ohms) that we bought demonstrates that the problem lies with the Lakeshore electronics.

One 218 has been sent back to Lakeshore for corrected calibration. All 218s demonstrate the same problem and will be sent back to Lakeshore.

The temperature sensor system is presently operational with the Keithleys and the simple daq provided by Keithley.

The Conway/Qian DAQ handles 218s, the IRM, the FISO fiber optic transducers, and the PCI-MIO-E16 ADC.

Page 19: Temperature Sensor Experiment - CAPP Maincapp/mucool/lh2/Errede17may04.pdf · Absorber Instrumentation The absorber environment: ... Figure 2: Electronic Connections Keithley switch

Conclusions

Recalibrate the 218s