2
5/26/2018 TEMAStandardsUpdates-slidepdf.com http://slidepdf.com/reader/full/tema-standards-updates 1/2 28/3/2014 TEMA Standards Updates http://www.tema.org/users/updates.asp 1/1 TEMA STANDARDS UPDATES The following pages have been updated. The version number corresponds to the first three digits of the serial number of your book. For example, if you have 902 as your first three digits, then an update labeled 901 or 902 does not apply to you since it is already included in your copy (and therefore is not shown here), but a 903 or higher update does apply. Version Page Description of Change 901 5.11-2 Paragraph RCB-11.4 (which is the same as it was in the Eighth Edition) had  been inadvertently left out.  902 10-21 Paragraph RGP-RCB-10.7 revised: (πd2t) should be  (πd 2 t)  in three places 903 2-3 Dimension R3 was shown as 1/4" but should be 1/16" 903 3-7 G-7.13 REFERENCE (12) Moss, Dennis R., "Pressure Vessel Design Manual," 1987, Gulf Publishing Company. Changed to: (12) Moss, Dennis R., "Pressure Vessel Design Manual: Illustrated Procedures for Solving Major Pressure Vessel Design Problems” Edition: 3, Publisher: Gulf Pub Co (December 18, 2003)  903 10-20 Mr in figure RGP- RCB-10.6 changed to Mt for consistency with RGP- RCB-10.7  904 2-3 Figure F-3, in the top section, dimension D1 shown in leftmost  part of Standard Confined Joint Construction was  pointing at the wrong corner. Was: Should be: 906 5.4-2, 5.4-3 In Tables R-4.41 and CB-4.41 the conversion of 5/16" should be 7.9 mm not 7.5 mm  909 5.4-3 In Table CB-4.41, bottom row, the conversion of 5/8" should be 15.9 mm not 12.7 mm  User Area Index

TEMA Standards Updates

Embed Size (px)

DESCRIPTION

tema standard

Citation preview

  • 28/3/2014 TEMA Standards Updates

    http://www.tema.org/users/updates.asp 1/1

    TEMA STANDARDS UPDATES

    The following pages have been updated. The version number corresponds to the first three digits of the serial number ofyour book. For example, if you have 902 as your first three digits, then an update labeled 901 or 902 does not apply to

    you since it is already included in your copy (and therefore is not shown here), but a 903 or higher update does apply.

    Version Page Description of Change

    901 5.11-2 Paragraph RCB-11.4 (which is the same as it was in the Eighth Edition) hadbeen inadvertently left out.

    902 10-21 Paragraph RGP-RCB-10.7 revised: (d2t) should be (d2t) in three places

    903 2-3 Dimension R3 was shown as 1/4" but should be 1/16"

    903 3-7 G-7.13 REFERENCE (12) Moss, Dennis R., "Pressure Vessel Design Manual," 1987, Gulf

    Publishing Company.Changed to:(12) Moss, Dennis R., "Pressure Vessel Design Manual: IllustratedProcedures for Solving Major Pressure Vessel Design Problems Edition: 3,Publisher: Gulf Pub Co (December 18, 2003)

    903 10-20 Mr in figure RGP-RCB-10.6 changed to Mt for consistency with RGP-RCB-10.7

    904 2-3 Figure F-3, in thetop section,

    dimension D1shown in leftmost part of Standard

    Confined JointConstruction was

    pointing at thewrong corner.

    Was: Should be:

    906 5.4-2, 5.4-3 In Tables R-4.41 and CB-4.41 the conversion of 5/16" should be 7.9 mmnot 7.5 mm

    909 5.4-3 In Table CB-4.41, bottom row, the conversion of 5/8" should be 15.9 mm

    not 12.7 mm