HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 1 of 29
Table of Contents
1. General Information ....................................................................................................................................... 2
1.1 Product Information ............................................................................................................................ 3
1.2 Test Methodology ............................................................................................................................... 5
1.3 Test Facility ......................................................................................................................................... 6
1.4 System Test Configuration .................................................................................................................. 7
1.4.1 Tested of Setup System ........................................................................................................... 7
1.4.1.1Configuration of Test System ....................................................................................... 7
1.4.1.2 Support Equipment List ............................................................................................... 8
1.4.2 EUT Exercise Software ........................................................................................................... 9
1.4.3 Justification .............................................................................................................................. 9
2. EMI Test ...................................................................................................................................................... 10
2.1 Conducted Emission .......................................................................................................................... 10
2.1.1 Conducted Emission Limit .................................................................................................... 10
2.1.2 Conducted Emission Test Equipment .................................................................................... 10
2.1.3 Conducted Emission Test ...................................................................................................... 11
2.1.3.1 Conducted Emission Test Data .................................................................................. 11
2.2 Radiated Emission ............................................................................................................................. 15
2.2.1 Radiated Emission Limit ....................................................................................................... 15
2.2.2 Radiated Emission Test Equipment ....................................................................................... 15
2.2.3 Radiated Emission Test ......................................................................................................... 16
2.2.3.1 Radiated Emission Test Data ..................................................................................... 16
2.2.4 Field Strength Calculation ..................................................................................................... 18
3. Photographs of Test Setup ........................................................................................................................... 19
3.1 Test Setup of Radiated Emission Test ............................................................................................... 19
3.2 Test Setup of Conducted Emission Test ............................................................................................ 20
4. Photographs of EUT .................................................................................................................................... 21
5. Attached Test Data for BR1000G-JP : ......................................................................................................... 23
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 2 of 29
1. General Information
Applicant : American Power Conversion Holding Inc. Taiwan Branch
Address : 3F, No. 205, Sec. 3, Beishin Rd., Shindian City, Taipei, Taiwan, 231, R.O.C.
Manufacturer : American Power Conversion Holding Inc. Taiwan Branch
Address : 3F, No. 205, Sec. 3, Beishin Rd., Shindian City, Taipei, Taiwan, 231, R.O.C.
Description of EUT : Uninterruptible Power System
Trade Name : APC
Model Number : BR1200G-JP; BR1000G-JP
Serial Model : BR1200XXXXXXXXXX; BR1000GXX-XXXX ("X" can be any alphanumeric or blank)
Report Number : HA090238-SAVI
Receipt Date : 19-OCT-2009
Issued Date : 19-JAN-2010
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 3 of 29
1.1 Product Information EUT Information
Description of EUT : Uninterruptible Power System
Trade Name : APC
Model Number : BR1200G-JP
Serial Number : N/A
Power during test : 100VAC/50Hz
Power Cable Type : 3 Pins, Unshielded, 2m (Undetachable).
I/O Port of EUT
I/O Port Type Q’TY Tested With Cable
1.) Data port ( USB to RJ45 TYPE ) 1 1 Shielded, 2m with core*1.
2.) Tel/Network port 2 2 Unshielded, 1m.
3.) Coaxial port 2 2 Shielded, 1m.
4.) AC Outlet ( Surge Only ) 5 5 Unshielded, 1.8m.
5.) AC Outlet ( Battery Back Up ) 5 5 Unshielded, 1.8m.
6.) AC Inlet 1 1 Unshielded, 2m.
7.) Battery Pack 1 1 Unshielded, 0.3m
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 4 of 29
Specifications
Model BR1200G-JP
Input
Norminal Voltage 100Vac
Rated Voltage 100Vac
Frequency 50/60Hz
Rated Current 12A
Input Voltage Range for Utility Operation 79~126Vac
Output
Voltage(on-line) 91.8~108.2Vac
Voltage(on-battery) 100Vac +/-8%
Frequency 50 or 60Hz +/-1%
Rated VA 1200VA
Rated Watts 720W
Rated Current 6A
Outlets 10 outlets
Pack RJ45 Connector Tel/network
USB Connector 10P10C RJ45 Full speed The model number as listed had been investigated which compliance with the requirement standard,
there are the same appearance function and schematic but the model number is difference for customer. Model Number: BR1200G-JP; BR1200XXXXXXXXXX ("X" can be any alphanumeric or blank). Specifications: Model Number BR1000G-JP
VA 1000VA
Maximum Load 600W
Nominal Input Voltage 100V
Online Input Voltage Range 82-123V
Automatic Voltage Regulation +11.2% Boost Only
Frequency Range 50/60 Hz ±1Hz
On-battery Wave shape Step-approximated sine-wave
Typical Recharge Time 8 hours
Transfer time 10ms, maximum
Operating temperature 32 to 104(0 to 40)
Storage temperature 23 to 113(-15 to 45)
Unit dimensions 3.93*9.84*15 in(10*25*38cm)
Unit weight 10.6kg(23.2lbs)
The model number as listed had been investigated which compliance with the requirement standard, there are the same appearance function and schematic but the model number is difference for difference customer. Model Number: BR1000G-JP; BR1000GXX-XXXX ("X" can be any alphanumeric or blank).
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 5 of 29
1.2 Test Methodology
a. The emission tests was performed according to the following methods and procedures:
VCCI (2008)
V-1/2007.09
Agreement of Voluntary Control Council for Interference by Information Technology Equipment
V-2/2008.04
Rules for Voluntary Control Measures
V-3/2008.04
Normative Annex 1: Technical Requirements
V-4/2007.04
Normative Annex 1-1: Supplementary Test Conditions for Equipment under Test
V-12/2008.04
Normative Annex 1-2: Procedure for Measuring the Normalized Site Attenuation by Use of a Dipole
Antenna and General Guidance on It
V-10/2008.04
Normative Annex 1-3: Calibration and Inspection of Measurement Equipment
V-5/2008.04
Normative Annex 2: Rules for Registration of Measurement Facilities
V-6/2006.04
Normative Annex 2-1: Guidelines for Management of Measurement Facilities
V-11/2008.04
Normative Annex 2-2: Outline how to fill Registration Documents of Measurement Facilities
V-7/2008.04
Normative Annex 3: Rules for Market Sampling Test
V-A2/2006.04
Rules of Voluntary Control Measure for Kit Module
V-A3/2006.04
Technical requirements for Kit Module
V-A4/2005.04
Normative Annex 1-1: Conditions for measuring disturbances from kit module under test
V-A5/2006.04
Normative Annex 2: Rules for Submission of Measurement Facilities for Kit Module
b. Description of departing from standard test method & any other specific: NONE
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 6 of 29
1.3 Test Facility The HongAn TECHNOLOGY CO., LTD. test site located at: No 15-1, Cweishuh Keng, Cweipin
Village,Linkou, Taipei County, Taiwan, R. O. C.
It is an open field test site, capable of measuring ITE products with the product on turntable (dimension
of 1.2 meters) to antenna at distance of 3 and 10 meters.
Anechoic chamber 9m (H) X 6m (W) X 6m (L) is compliance with the sixteen point uniform field
requirement as stated in IEC 61000-4-3/EN 61000-4-3.
It is an EMS test site, Capable of measuring Industrial, Scientific and Medical Instrument, Information
Technology Equipment, broadcast receivers and related equipments and household appliances/tools.
It is owned and operated by HongAn TECHNOLOGY CO., LTD.
A site description and calibration report to ANSI C 63.4 is available upon request.
A site description and calibration report to EN61000-6-3 & EN55024 is available upon request.
The test site is authorized for testing Industrial, Scientific and Medical Instrument, Information
Technology Equipment, broadcast receivers and related equipments and household Appliances / tools
by BSMI.
Nemko authorizes the test site for testing Uninterruptible Power System and Automatic Voltage
Regulator.
BSMI certification #: SL2-IS-E-0023, SL2-IN-E-0023, SL2-R1-E-0023, SL2-R2-E-0023,
And SL2-A1-E-0023.
Nemko authorization #: ELA 184
VCCI Certificate #: R-2156,C-2329,T-219
TAF Accreditation Number: 1163
FCC Designation Number: TW1001
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 7 of 29
1.4 System Test Configuration 1.4.1 Tested of Setup System 1.4.1.1Configuration of Test System
EUT EUT
Battery
Box
Lamp
Lamp
PC Monitor
Modem
Keyboard
DUP*10
UUP
UUP
DSD
UTP*2
DUP
DUP
DUP
DSD
DSD
USD
USD
Mouse
DSD
DSD
75Ω
100Ω
75Ω
Legend:
UTP:Unshielded Data Twisted Pair Cable.
DUP:Detachable Unshielded Power Cord.
UUP:Undetachable Unshielded Power Cord.
USP:Undetachable Shielded Power Cord.
USD:Undetachable Shielded Data Cable.
DSD:Detachable Shielded Data Cable
UUD:Undetachable Unshielded Data Cable
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 8 of 29
1.4.1.2 Support Equipment List
Equipment Model
Number Serial
Number EMC
Approved Manufacturer
Description
Data Cable Power Cable
Data Cable USB To
RJ45 Type N/A N/A APC
Shielded (Braid) , 2m
with core*1 N/A
Coaxial Cable RG59 Type N/A N/A HongAn Shielded (Braid),
1m. N/A
Tel/Network Cable
RJ45 Type N/A N/A HongAn Unshielded ,
1m N/A
AC Power Cable
18AWGX3C N/A N/A N/A N/A Unshielded,
1.8m
R 75 ohm N/A N/A HongAn Coaxial Cable N/A
R 100 ohm N/A N/A HongAn Tel/Network Cable N/A
Light Box LAMP 700W N/A N/A HongAn N/A
AC Power Cable
(Battery Backup)
Light Box LAMP 20W N/A N/A HongAn N/A AC Power
Cable (Surge only)
Light Box LAMP 10W N/A N/A HongAn N/A AC Power
Cable (Surge only)
Monitor SDM-X73 9273312 FCC DoC SONY Shielded (Braid),
1.8m, with core*2
Unshielded, 1.8m
PC DCTA 5MCGJ1S FCC DoC, CE Mark
DELL Data Cable Unshielded,
1.8m
Modem E210 106-02100258FCC DoC, CE Mark
MITAC Shielded (Braid),
1m
Unshielded, 1.5m
with core*1
Keyboard Y-UR83 868017-0121FCC DoC, CE Mark
Logitech Shielded (Foil),
1.8m N/A
Mouse M-BT83 810-000361 FCC DoC Logitech Shielded (Foil),
1.8m N/A
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 9 of 29
1.4.2 EUT Exercise Software
1.Turn on the power of all support equipment.
2.Turn on the power of EUT.
3.PC read messages by EUT connect cable when Execution software of EUT. 1.4.3 Justification
The tested setup for EUT in the report was appointed according to the customer.
The worse case of the conducted disturbance at the telecommunication port measurement occurred at
0.150MHz (Phase), -8.360dB (Average).
The worst case of the radiated measurements is -4.07dB(Quasi Peak) occurred at 192.01MHz (Vertical),
110cm antenna height and 86degree turn table angle.
※The test data of tasted serial models is attached in the attachment
※AC power outlet cable is 1m (3Pins, unshielded) for BR1000G-JP.
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 10 of 29
2. EMI Test 2.1 Conducted Emission 2.1.1 Conducted Emission Limit Limits for conducted disturbance at main ports of Class B ITE
Frequency range Quasi-Peak Average
0.15~0.50 66~56 56~46
0.50~5.0 56 46
5.0~30 60 50
Notes 1- At the transition frequencies the lower limit applies. Notes 2- The limit decreases linearly with the logarithm of the frequency in the range0.15MHz to 0.50MHz. Limits for conducted common-mode (asymmetric mode) disturbance at telecommunication ports
for class B equipment
Frequency range MHz
Voltage limits dB (uV)
Current limits dB(uA)
Quasi-peak Average Quasi-peak Average
0.15 ~ 0.5 84 ~ 74 74 ~ 64 40 ~ 30 30 ~ 20
0.5 ~ 30 74 64 30 20
NOTE 1-The limits decrease linearly with the logarithm of the frequency in the range 0.15 MHz to 0.5 MHz. NOTE 2-The current and voltage disturbance limits are derived for use with an impedance stabilization network
(ISN)which presents a common mode (asymmetric mode) of 150 Ω to the telecommunication port under test (conversion factor is 20 log10 150 / 1 = 44 dB).
2.1.2 Conducted Emission Test Equipment
Instrument Name Manufacture Model Serial Number Last Cal. Date Next Cal. Date
EMI Test Signal Analyzer
PMM PMM 9000 4410J10302 13-JUL-2009 13-JUL-2010
LISN EMCO 3810/2NM 9702-1820 21-JUL-2009 21-JUL-2010
LISN Rolf Heine
Hochfrequenztechnik NNB-4/32T 00001 06-FEB-2009 06-FEB-2010
※ The test equipment used is calibrated and can be traced to National ITRI and International Standards ※ The result of the measurement, after all appropriate corrections have been made, is y and may typically be reported as follows:
The measured result is : y dBμ V ± 3.95 dB
for a level of confidence of approximately 95%, (K=2).
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 11 of 29
2.1.3 Conducted Emission Test
2.1.3.1 Conducted Emission Test Data Location : HA2 Power Mains : 100V/60Hz
Model : BR1200G-JP Humidity : 60%
Description : Phase Temperature : 23
Frequency (MHz)
MeasureddB (µV)
Corr. Factor dB
Total dB (µV)
Limit (AV)dB (µV)
Limit (QP)dB (µV)
Margin dB
Note
0.150 47.400 0.240 47.640 56.000 66.000 -8.360 P AV 0.150 53.600 0.240 53.840 56.000 66.000 -12.160 P QP 0.776 30.900 0.200 31.100 46.000 56.000 -24.900 P QP 0.776 25.200 0.200 25.400 46.000 56.000 -20.600 P AV 1.476 17.100 0.250 17.350 46.000 56.000 -28.650 P AV 1.476 26.900 0.250 27.150 46.000 56.000 -28.850 P QP 2.828 28.200 0.310 28.510 46.000 56.000 -27.490 P QP 2.828 19.100 0.310 19.410 46.000 56.000 -26.590 P AV 3.350 28.100 0.330 28.430 46.000 56.000 -27.570 P QP 3.350 19.800 0.330 20.130 46.000 56.000 -25.870 P AV 9.791 32.000 0.660 32.660 50.000 60.000 -17.340 P AV 9.791 38.300 0.660 38.960 50.000 60.000 -21.040 P QP
Peak, Average. And QP signifies the measurement detector used for performing measurements.
Negative number in the margin column indicates the amount (in dB) that the recorded emission is below the limit.
P denotes Phase, N denotes Neutral, AV denotes Average, QP denotes Quasi-Peak.
For the same frequency only the highest reading of Phase or Neutral conductor is reported.
Calculation of result for Frequency (MHz): Measured (dBµV) + Correction Factor = Total (dBµV)
Correction Factor =Insertion loss+ Cable loss. Margin value = (Measured+ Correction Factor) – limit value. Test Number: 2CEA1904 Test Date: 19-OCT-2009 Tested By: H.B.LIANG
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 12 of 29
Conducted Test Data Location : HA2 Power Mains : 100V/60Hz
Model : BR1200G-JP Humidity : 60%
Description : Neutral Temperature : 23
Frequency (MHz)
MeasureddB (µV)
Corr. Factor dB
Total dB (µV)
Limit (AV)dB (µV)
Limit (QP)dB (µV)
Margin dB
Note
0.150 42.700 0.210 42.910 56.000 66.000 -13.090 N AV 0.150 50.400 0.210 50.610 56.000 66.000 -15.390 N QP 0.525 36.100 0.160 36.260 46.000 56.000 -19.740 N QP 0.525 28.800 0.160 28.960 46.000 56.000 -17.040 N AV 1.049 24.500 0.190 24.690 46.000 56.000 -21.310 N AV 1.049 30.900 0.190 31.090 46.000 56.000 -24.910 N QP 1.951 28.100 0.230 28.330 46.000 56.000 -27.670 N QP 1.951 19.700 0.230 19.930 46.000 56.000 -26.070 N AV 2.973 19.600 0.280 19.880 46.000 56.000 -26.120 N AV 2.973 27.500 0.280 27.780 46.000 56.000 -28.220 N QP 9.775 28.600 0.570 29.170 50.000 60.000 -30.830 N QP 9.775 23.700 0.570 24.270 50.000 60.000 -25.730 N AV
Peak, Average. And QP signifies the measurement detector used for performing measurements.
Negative number in the margin column indicates the amount (in dB) that the recorded emission is below the limit.
P denotes Phase, N denotes Neutral, AV denotes Average, QP denotes Quasi-Peak.
For the same frequency only the highest reading of Phase or Neutral conductor is reported.
Calculation of result for Frequency (MHz): Measured (dBµV) + Correction Factor = Total (dBµV)
Correction Factor =Insertion loss+ Cable loss. Margin value = (Measured+ Correction Factor) – limit value. Test Number: 2CEA1904 Test Date: 19-OCT-2009 Tested By: H.B.LIANG
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 13 of 29
Conducted Test Data Location : HA2 Power Mains : Battery mode
Model : BR1200G-JP Humidity : 60%
Description : Phase Temperature : 23
Frequency (MHz)
MeasureddB (µV)
Corr. Factor dB
Total dB (µV)
Limit (AV)dB (µV)
Limit (QP)dB (µV)
Margin dB
Note
0.245 26.800 0.170 26.970 51.920 61.920 -34.950 P QP 0.245 26.200 0.170 26.370 51.920 61.920 -25.550 P AV 0.982 18.100 0.210 18.310 46.000 56.000 -27.690 P AV 0.982 23.900 0.210 24.110 46.000 56.000 -31.890 P QP 2.397 32.900 0.300 33.200 46.000 56.000 -22.800 P QP 2.397 26.700 0.300 27.000 46.000 56.000 -19.000 P AV 3.869 33.700 0.350 34.050 46.000 56.000 -11.950 P AV 3.869 39.700 0.350 40.050 46.000 56.000 -15.950 P QP 5.394 38.500 0.460 38.960 50.000 60.000 -21.040 P QP 5.394 31.800 0.460 32.260 50.000 60.000 -17.740 P AV 11.540 29.000 0.730 29.730 50.000 60.000 -20.270 P AV 11.540 38.600 0.730 39.330 50.000 60.000 -20.670 P QP
Peak, Average. And QP signifies the measurement detector used for performing measurements.
Negative number in the margin column indicates the amount (in dB) that the recorded emission is below the limit.
P denotes Phase, N denotes Neutral, AV denotes Average, QP denotes Quasi-Peak.
For the same frequency only the highest reading of Phase or Neutral conductor is reported.
Calculation of result for Frequency (MHz): Measured (dBµV) + Correction Factor = Total (dBµV)
Correction Factor =Insertion loss+ Cable loss. Margin value = (Measured+ Correction Factor) – limit value. Test Number: 2CEA1903 Test Date: 19-OCT-2009 Tested By: H.B.LIANG
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 14 of 29
Conducted Test Data Location : HA2 Power Mains : Battery mode
Model : BR1200G-JP Humidity : 60%
Description : Neutral Temperature : 23
Frequency (MHz)
MeasureddB (µV)
Corr. Factor dB
Total dB (µV)
Limit (AV)dB (µV)
Limit (QP)dB (µV)
Margin dB
Note
0.164 26.800 0.180 26.980 55.250 65.250 -28.270 N AV 0.164 31.800 0.180 31.980 55.250 65.250 -33.270 N QP 1.035 22.100 0.190 22.290 46.000 56.000 -33.710 N QP 1.035 17.100 0.190 17.290 46.000 56.000 -28.710 N AV 2.506 35.000 0.260 35.260 46.000 56.000 -20.740 N QP 2.506 29.000 0.260 29.260 46.000 56.000 -16.740 N AV 3.757 35.700 0.300 36.000 46.000 56.000 -10.000 N AV 3.757 41.600 0.300 41.900 46.000 56.000 -14.100 N QP 5.722 33.500 0.410 33.910 50.000 60.000 -16.090 N AV 5.722 40.200 0.410 40.610 50.000 60.000 -19.390 N QP 11.165 36.400 0.600 37.000 50.000 60.000 -23.000 N QP 11.165 26.200 0.600 26.800 50.000 60.000 -23.200 N AV
Peak, Average. And QP signifies the measurement detector used for performing measurements.
Negative number in the margin column indicates the amount (in dB) that the recorded emission is below the limit.
P denotes Phase, N denotes Neutral, AV denotes Average, QP denotes Quasi-Peak.
For the same frequency only the highest reading of Phase or Neutral conductor is reported.
Calculation of result for Frequency (MHz): Measured (dBµV) + Correction Factor = Total (dBµV)
Correction Factor =Insertion loss+ Cable loss. Margin value = (Measured+ Correction Factor) – limit value. Test Number: 2CEA1903 Test Date: 19-OCT-2009 Tested By: H.B.LIANG
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 15 of 29
2.2 Radiated Emission 2.2.1 Radiated Emission Limit Limits for radiated disturbance of Class B ITE at a measuring distance of 10m
Frequency range Quasi-peak
30 MHz – 230 MHz 30 dB
230 MHz - 1000 MHz 37 dB
Note 1: The lower limit shall apply at the transition frequency. Note 2: A measuring distance of 10 m is a primary requirement. However, distance of either 3 m or 30 m may also
be allowed for the measurement with facilities registered as such in accordance. 2.2.2 Radiated Emission Test Equipment
Instrument Name Manufacture Model Serial Number Last Cal. Date Next Cal. Date
EMI Test Signal Analyzer
PMM PMM 9000 4410J10302 13-JUL-2009 13-JUL-2010
Spectrum Analyzer ADVANTEST R3172 101202158 24-JUN-2009 24-JUN-2010
Preamplifier CHASE CPA 9231A 3310 09-JUL-2009 09-JUL-2010
Bilog Antenna CHASE CBL 6112B 2860 12-AUG-2009 12-AUG-2010
※ The test equipment used is calibrated and can be traced to National ITRI and International Standards. ※ The result of the measurement, after all appropriate corrections have been made, is y and may typically be reported as follows:
The measured result is : y dBμ V ± 5.04dB
for a level of confidence of approximately 95%, (K=2).
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 16 of 29
2.2.3 Radiated Emission Test 2.2.3.1 Radiated Emission Test Data The following data lists the significant emission frequencies measured levels, correction factor
(includes cable and antenna corrections) plus the limit. Explanation of the correction factor is
given in paragraph 2.2.4
Location : HA2
Model : BR1200G-JP Humidity : 60%
Serial Number : N/A Temperature : 25
Description : 100V/60Hz
Frequency (MHz)
Receiver Reading dB(µV/m)
Correction Factor
dB
CorrectionReading dB(µV/m)
Limit dB(µV/m)
Margin limit dB
Pol.Antenna Height ( cm )
Table Ang.
( deg. ) Note
30.52 5.08 19.19 24.27 30.00 -5.73 H 400 0 QP
30.62 6.80 19.13 25.93 30.00 -4.07 V 100 340 QP
58.47 16.05 8.25 24.30 30.00 -5.70 V 100 27
59.52 11.75 8.07 19.82 30.00 -10.18 H 392 82
74.71 14.32 8.18 22.50 30.00 -7.50 V 105 206
84.86 9.92 9.48 19.40 30.00 -10.60 H 398 316
113.20 6.68 13.63 20.31 30.00 -9.69 H 393 218
113.71 7.50 13.64 21.14 30.00 -8.86 V 100 74
148.31 7.77 12.20 19.97 30.00 -10.03 H 400 206
152.62 8.32 11.92 20.24 30.00 -9.76 V 108 112
192.01 14.30 10.73 25.03 30.00 -4.97 V 113 348 QP
192.01 9.42 10.73 20.15 30.00 -9.85 H 384 193
Negative number in the margin column indicates the amount (in dB) that the recorded emission is Below the limit.
V means in Vertical Antenna Polarization, H means in Horizontal, and QP means in Quasi-Peak.
Unless stated otherwise, all readings are measured peak with an IF bandwidth not less than 120KHz.
If a spectrum analyzer is used, the sweep time and video filter settings will not affect the readings.
Radiated emissions for this type of product do not change with the AC power operating voltage.
Test Number: 2REA2010 Test Date: 20-OCT-2009 Tested By: H.B.LIANG
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 17 of 29
Radiated Test Data Location : HA2
Model : BR1200G-JP Humidity :60%
Serial Number : N/A Temperature : 25
Description : Battery mode
Frequency (MHz)
Receiver Reading dB(µV/m)
Correction Factor
dB
CorrectionReading dB(µV/m)
Limit dB(µV/m)
Margin limit dB
Pol.Antenna Height ( cm )
Table Ang.
( deg. ) Note
30.58 5.26 19.15 24.41 30.00 -5.59 H 400 0 QP
30.70 6.60 19.08 25.68 30.00 -4.32 V 100 339 QP
58.42 16.36 8.26 24.62 30.00 -5.38 V 103 35
59.58 11.57 8.06 19.63 30.00 -10.37 H 397 64
79.30 10.67 8.48 19.15 30.00 -10.85 H 392 173
84.46 14.72 9.41 24.13 30.00 -5.87 V 108 309
112.84 8.67 13.62 22.29 30.00 -7.71 H 390 352
125.03 8.24 13.68 21.92 30.00 -8.08 V 105 183
142.25 10.17 12.75 22.92 30.00 -7.08 H 400 196
145.03 10.78 12.49 23.27 30.00 -6.73 V 100 164
192.00 14.28 10.73 25.01 30.00 -4.99 H 388 265
192.01 15.20 10.73 25.93 30.00 -4.07 V 110 86 QP
Negative number in the margin column indicates the amount (in dB) that the recorded emission is Below the limit.
V means in Vertical Antenna Polarization, H means in Horizontal, and QP means in Quasi-Peak.
Unless stated otherwise, all readings are measured peak with an IF bandwidth not less than 120KHz.
If a spectrum analyzer is used, the sweep time and video filter settings will not affect the readings.
Radiated emissions for this type of product do not change with the AC power operating voltage.
Test Number: 2REA2009 Test Date: 20-OCT-2009 Tested By: H.B.LIANG
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 18 of 29
2.2.4 Field Strength Calculation
The field strength is calculated by adding the Correction factor to the receiver or analyzer reading
to determine the resultant field strength.
The correction factor is determined by adding the antenna factor and the loss of the cables
connection the antenna to the receiver.
Front-end amplifier gain - if any - is accounted for in the receiver reading. The basic equation
with a sample calculation is as follows:
FS = RA + CF
Where the Correction factor CF is the sum of the Antenna Factor AF and the Cable loss factor CL;
CF = AF + CL
FS = Field Strength
AF = Antenna Factor
CL = Cable Loss factor
RA = Receiver Amplitude
Assume a receiver reading of 22dB(V/m) is obtained. The Antenna factor of 7.4dB and a cable
loss factor of 1.1dB are added to yield 8.5dB Correction Factor.
The Calculated Field Strength is the sum of 22 + 8.5 = 30.5dB(V/m).
All values are listed as dB, either referenced to 1V or 1V/m .
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 19 of 29
3. Photographs of Test Setup 3.1 Test Setup of Radiated Emission Test
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 20 of 29
3.2 Test Setup of Conducted Emission Test
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 21 of 29
4. Photographs of EUT 4.1 EUT Front Side (BR1200G-JP)
4.2 EUT Rear Side (BR1200G-JP)
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 22 of 29
4.3 EUT Front Side (BR1000G-JP)
4.4 EUT Rear Side (BR1000G-JP)
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 23 of 29
5. Attached Test Data for BR1000G-JP :
Conducted Emission Test Data…………………………………………………………24
Radiated Emission Test Data……………………………………………………………28
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 24 of 29
Conducted Emission Test Data Location : HA2 Power Mains : 100V/60Hz
Model : BR1000G-JP Humidity : 57%
Description : Phase Temperature : 20
Frequency (MHz)
MeasureddB (µV)
Corr. Factor dB
Total dB (µV)
Limit (AV)dB (µV)
Limit (QP)dB (µV)
Margin dB
Note
0.150 23.500 0.220 23.720 56.000 66.000 -32.280 P AV 0.150 40.000 0.220 40.220 56.000 66.000 -25.780 P QP 0.185 26.100 0.150 26.250 54.250 64.250 -38.000 P QP 0.185 17.400 0.150 17.550 54.250 64.250 -36.700 P AV 4.258 11.500 0.240 11.740 46.000 56.000 -34.260 P AV 4.258 19.400 0.240 19.640 46.000 56.000 -36.360 P QP 7.052 21.400 0.410 21.810 50.000 60.000 -38.190 P QP 7.052 15.400 0.410 15.810 50.000 60.000 -34.190 P AV
13.808 13.500 0.640 14.140 50.000 60.000 -35.860 P AV 13.808 18.500 0.640 19.140 50.000 60.000 -40.860 P QP 18.439 24.100 0.800 24.900 50.000 60.000 -35.100 P QP 18.439 17.100 0.800 17.900 50.000 60.000 -32.100 P AV
Peak, Average. And QP signifies the measurement detector used for performing measurements.
Negative number in the margin column indicates the amount (in dB) that the recorded emission is below the limit.
P denotes Phase, N denotes Neutral, AV denotes Average, QP denotes Quasi-Peak.
For the same frequency only the highest reading of Phase or Neutral conductor is reported.
Calculation of result for Frequency (MHz): Measured (dBµV) + Correction Factor = Total (dBµV)
Correction Factor =Insertion loss+ Cable loss. Margin value = (Measured+ Correction Factor) – limit value. Test Number: 2CE10604 Test Date: 06-JAN-2010 Tested By: H.B.LIANG
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 25 of 29
Conducted Emission Test Data Location : HA2 Power Mains : 100V/60Hz
Model : BR1000G-JP Humidity : 57%
Description : Neutral Temperature : 20
Frequency (MHz)
MeasureddB (µV)
Corr. Factor dB
Total dB (µV)
Limit (AV)dB (µV)
Limit (QP)dB (µV)
Margin dB
Note
0.152 20.300 0.200 20.500 55.880 65.880 -35.380 N AV 0.152 35.600 0.200 35.800 55.880 65.880 -30.080 N QP 0.210 28.200 0.110 28.310 53.200 63.200 -34.890 N QP 0.210 18.900 0.110 19.010 53.200 63.200 -34.190 N AV 4.797 17.600 0.290 17.890 46.000 56.000 -38.110 N QP 4.797 9.900 0.290 10.190 46.000 56.000 -35.810 N AV 7.140 16.200 0.430 16.630 50.000 60.000 -33.370 N AV 7.140 22.100 0.430 22.530 50.000 60.000 -37.470 N QP
15.423 26.100 0.740 26.840 50.000 60.000 -33.160 N QP 15.423 20.500 0.740 21.240 50.000 60.000 -28.760 N AV 18.728 18.700 0.880 19.580 50.000 60.000 -30.420 N AV 18.728 28.000 0.880 28.880 50.000 60.000 -31.120 N QP
Peak, Average. And QP signifies the measurement detector used for performing measurements.
Negative number in the margin column indicates the amount (in dB) that the recorded emission is below the limit.
P denotes Phase, N denotes Neutral, AV denotes Average, QP denotes Quasi-Peak.
For the same frequency only the highest reading of Phase or Neutral conductor is reported.
Calculation of result for Frequency (MHz): Measured (dBµV) + Correction Factor = Total (dBµV)
Correction Factor =Insertion loss+ Cable loss. Margin value = (Measured+ Correction Factor) – limit value. Test Number: 2CE10604 Test Date: 06-JAN-2010 Tested By: H.B.LIANG
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 26 of 29
Conducted Emission Test Data Location : HA2 Power Mains : Battery mode
Model : BR1000G-JP Humidity : 57%
Description : Phase Temperature : 20
Frequency (MHz)
MeasureddB (µV)
Corr. Factor dB
Total dB (µV)
Limit (AV)dB (µV)
Limit (QP)dB (µV)
Margin dB
Note
0.155 38.000 0.210 38.210 55.720 65.720 -17.510 P AV 0.155 60.600 0.210 60.810 55.720 65.720 -4.910 P QP 0.549 47.800 0.110 47.910 46.000 56.000 -8.090 P QP 0.549 31.700 0.110 31.810 46.000 56.000 -14.190 P AV 0.698 30.600 0.110 30.710 46.000 56.000 -15.290 P AV 0.698 47.200 0.110 47.310 46.000 56.000 -8.690 P QP 1.200 36.700 0.130 36.830 46.000 56.000 -19.170 P QP 1.200 22.700 0.130 22.830 46.000 56.000 -23.170 P AV 2.600 19.800 0.180 19.980 46.000 56.000 -26.020 P AV 2.600 36.500 0.180 36.680 46.000 56.000 -19.320 P QP
12.384 38.300 0.600 38.900 50.000 60.000 -21.100 P QP 12.384 12.500 0.600 13.100 50.000 60.000 -36.900 P AV
Peak, Average. And QP signifies the measurement detector used for performing measurements.
Negative number in the margin column indicates the amount (in dB) that the recorded emission is below the limit.
P denotes Phase, N denotes Neutral, AV denotes Average, QP denotes Quasi-Peak.
For the same frequency only the highest reading of Phase or Neutral conductor is reported.
Calculation of result for Frequency (MHz): Measured (dBµV) + Correction Factor = Total (dBµV)
Correction Factor =Insertion loss+ Cable loss. Margin value = (Measured+ Correction Factor) – limit value. Test Number: 2CE10605 Test Date: 06-JAN-2010 Tested By: H.B.LIANG
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 27 of 29
Conducted Emission Test Data Location : HA2 Power Mains : Battery mode
Model : BR1000G-JP Humidity : 57%
Description : Neutral Temperature : 20
Frequency (MHz)
MeasureddB (µV)
Corr. Factor dB
Total dB (µV)
Limit (AV)dB (µV)
Limit (QP)dB (µV)
Margin dB
Note
0.153 39.000 0.200 39.200 55.830 65.830 -16.630 N AV 0.153 60.400 0.200 60.600 55.830 65.830 -5.230 N QP 0.598 46.800 0.110 46.910 46.000 56.000 -9.090 N QP 0.598 30.700 0.110 30.810 46.000 56.000 -15.190 N AV 0.700 29.900 0.120 30.020 46.000 56.000 -15.980 N AV 0.700 48.300 0.120 48.420 46.000 56.000 -7.580 N QP 4.917 32.800 0.300 33.100 46.000 56.000 -22.900 N QP 4.917 6.100 0.300 6.400 46.000 56.000 -39.600 N AV 7.799 14.400 0.470 14.870 50.000 60.000 -35.130 N AV 7.799 32.600 0.470 33.070 50.000 60.000 -26.930 N QP
18.880 32.500 0.880 33.380 50.000 60.000 -26.620 N QP 18.880 29.600 0.880 30.480 50.000 60.000 -19.520 N AV
Peak, Average. And QP signifies the measurement detector used for performing measurements.
Negative number in the margin column indicates the amount (in dB) that the recorded emission is below the limit.
P denotes Phase, N denotes Neutral, AV denotes Average, QP denotes Quasi-Peak.
For the same frequency only the highest reading of Phase or Neutral conductor is reported.
Calculation of result for Frequency (MHz): Measured (dBµV) + Correction Factor = Total (dBµV)
Correction Factor =Insertion loss+ Cable loss. Margin value = (Measured+ Correction Factor) – limit value. Test Number: 2CE10605 Test Date: 06-JAN-2010 Tested By: H.B.LIANG
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 28 of 29
Radiated Emission Test Data
Location : HA2
Model : BR1000G-JP Humidity : 45%
Serial Number : N/A Temperature : 18
Description : 100V/60Hz
Frequency (MHz)
Receiver Reading dB(µV/m)
Correction Factor
dB
CorrectionReading dB(µV/m)
Limit dB(µV/m)
Margin limit dB
Pol.Antenna Height ( cm )
Table Ang.
( deg. ) Note
30.34 6.27 19.29 25.56 30.00 -4.44 V 100 0 QP
32.72 6.58 17.98 24.56 30.00 -5.44 H 400 290
57.14 16.50 8.48 24.98 30.00 -5.02 V 100 214 QP
57.66 14.86 8.39 23.25 30.00 -6.75 H 400 165 QP
69.84 17.95 7.85 25.80 30.00 -4.20 V 100 331 QP
79.70 13.37 8.51 21.88 30.00 -8.12 H 400 301
114.73 8.07 13.66 21.73 30.00 -8.27 V 100 139
120.87 4.67 13.76 18.43 30.00 -11.57 H 400 137
135.03 6.09 13.27 19.36 30.00 -10.64 H 397 313
143.13 9.50 12.67 22.17 30.00 -7.83 V 101 228
191.99 14.90 10.72 25.62 30.00 -4.38 V 104 286 QP
192.01 13.43 10.73 24.16 30.00 -5.84 H 398 291 QP
Negative number in the margin column indicates the amount (in dB) that the recorded emission is Below the limit.
V means in Vertical Antenna Polarization, H means in Horizontal, and QP means in Quasi-Peak.
Unless stated otherwise, all readings are measured peak with an IF bandwidth not less than 120KHz.
If a spectrum analyzer is used, the sweep time and video filter settings will not affect the readings.
Radiated emissions for this type of product do not change with the AC power operating voltage.
Test Number: 2RE11205 Test Date: 12-JAN-2010 Tested By: H.B.LIANG
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 29 of 29
Radiated Emission Test Data
Location : HA2
Model : BR1000G-JP Humidity :45%
Serial Number : N/A Temperature : 18
Description : Battery mode
Frequency (MHz)
Receiver Reading dB(µV/m)
Correction Factor
dB
CorrectionReading dB(µV/m)
Limit dB(µV/m)
Margin limit dB
Pol.Antenna Height ( cm )
Table Ang.
( deg. ) Note
30.63 6.79 19.12 25.91 30.00 -4.09 V 100 341 QP
39.16 6.23 15.03 21.26 30.00 -8.74 H 400 23 QP
45.77 10.60 11.53 22.13 30.00 -7.87 V 100 197 QP
54.59 10.67 8.93 19.60 30.00 -10.40 H 400 92 QP
71.99 12.61 7.99 20.60 30.00 -9.40 V 100 62 QP
85.39 6.58 9.58 16.16 30.00 -13.84 H 400 277 QP
110.44 4.21 13.57 17.78 30.00 -12.22 H 399 314 QP
120.06 7.42 13.77 21.19 30.00 -8.81 V 100 203 QP
142.84 7.32 12.69 20.01 30.00 -9.99 V 103 296 QP
152.38 6.53 11.93 18.46 30.00 -11.54 H 397 183 QP
192.00 15.24 10.72 25.96 30.00 -4.04 V 106 180 QP
192.01 13.77 10.73 24.50 30.00 -5.50 H 393 261 QP
Negative number in the margin column indicates the amount (in dB) that the recorded emission is Below the limit.
V means in Vertical Antenna Polarization, H means in Horizontal, and QP means in Quasi-Peak.
Unless stated otherwise, all readings are measured peak with an IF bandwidth not less than 120KHz.
If a spectrum analyzer is used, the sweep time and video filter settings will not affect the readings.
Radiated emissions for this type of product do not change with the AC power operating voltage.
Test Number: 2RE11204 Test Date: 12-JAN-2010 Tested By: H.B.LIANG
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 1 of 15
Attached Photographs of EUT
1. EUT Front Side .............................................................................................................................................. 2
2. EUT Rear Side ............................................................................................................................................... 2
3. EUT Inner View Front Side ........................................................................................................................... 3
5. EUT Main Board Front Side .......................................................................................................................... 4
6. EUT Main Board Rear Side ........................................................................................................................... 4
8. EUT Panel Board Rear Side .......................................................................................................................... 5
9. EUT AC Socket Front Side ............................................................................................................................ 6
11. EUT Transformer Front Side ....................................................................................................................... 7
12. EUT Transformer Rear Side ........................................................................................................................ 7
13. EUT Tel-Network Board Front Side ............................................................................................................ 8
14. EUT Tel-Network Board Rear Side ............................................................................................................. 8
15. EUT TVBS Board Front Side ...................................................................................................................... 9
16. EUT TVBS Board Rear Side ....................................................................................................................... 9
17. EUT Fan Front Side ................................................................................................................................... 10
18. EUT Fan Rear Side .................................................................................................................................... 10
19. EUT Battery Front Side ............................................................................................................................. 11
20. EUT Battery Rear Side .............................................................................................................................. 11
21. EUT Battery Box Front Side ...................................................................................................................... 12
22. EUT Battery Box Rear Side ....................................................................................................................... 12
23. EUT Battery Box Inner View Front Side ................................................................................................... 13
24. EUT Battery Box Inner View Rear Side .................................................................................................... 13
25. EUT Battery Front Side For Battery Box .................................................................................................. 14
26. EUT Battery Rear Side For Battery Box ................................................................................................... 14
27. EUT AC Pin Type ...................................................................................................................................... 15
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 2 of 15
1. EUT Front Side
2. EUT Rear Side
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 3 of 15
3. EUT Inner View Front Side
4. EUT Inner View Rear Side
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 4 of 15
5. EUT Main Board Front Side
6. EUT Main Board Rear Side
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 5 of 15
7. EUT Panel Board Front Side
8. EUT Panel Board Rear Side
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 6 of 15
9. EUT AC Socket Front Side
10. EUT AC Socket Rear Side
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 7 of 15
11. EUT Transformer Front Side
12. EUT Transformer Rear Side
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 8 of 15
13. EUT Tel-Network Board Front Side
14. EUT Tel-Network Board Rear Side
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 9 of 15
15. EUT TVBS Board Front Side
16. EUT TVBS Board Rear Side
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 10 of 15
17. EUT Fan Front Side
18. EUT Fan Rear Side
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 11 of 15
19. EUT Battery Front Side
20. EUT Battery Rear Side
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 12 of 15
21. EUT Battery Box Front Side
22. EUT Battery Box Rear Side
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 13 of 15
23. EUT Battery Box Inner View Front Side
24. EUT Battery Box Inner View Rear Side
HongAn TECHNOLOGY CO., LTD. Report Number: HA090238-SAVI Page 14 of 15
25. EUT Battery Front Side For Battery Box