TECHNICAL STANDARDSTO
MANAGEAIR POLLUTION
Version 51
Published by the
Minister of the Environment and Climate Change
February 27th 2018
PIBs 7306e05
Technical Standards to Manage Air Pollution
Cette publication hautement speacutecialiseacutee Technical Standards to Manage Air Pollution nest disponible quen anglais conformeacutement au Regraveglement 67192 selon lequel il nrsquoest pas obligatoire de la traduire en vertu de la Loi sur les services en franccedilais Pour obtenir des renseignements en franccedilais veuillez communiquer avec le ministegravere de lEnvironnement et de lrsquoAction en matiegravere de changement climatique au 327-5519 ou par courriel agrave SDBTechStdontarioca
Translation This highly specialized publication Technical Standards to Manage Air Pollution is available in English only in accordance with Regulation 67192 which exempts it from translation under the French Language Services Act To obtain information in French please contact the Ministry of the Environment and Climate Change at (416) 327-5519 or SDBTechStdontarioca
Ontario Ministry of the Environment and Climate Change
February 2018
As Minister of the Environment and Climate Change I am pleased to publish Version 51 of this ldquoTechnical Standards to Manage Air Pollutionrdquo (the Technical Standards publication) under section 38 of Ontario Regulation 41905 Air Pollution - Local Air Quality
This publication now includes amendments to the Petroleum Refining ndash Industry Standard the Petrochemical ndash Industry Standard and other minor administrative edits
All technical standards are available on our ministry website as well as through the ministryrsquos Public Information Centre
Technical Standards to Manage Air Pollution
Ministry of the Ministegravere de Environment lEnvironnemen and Climate t et de lrsquoAction Change en matiegravere de
changement Office of the Minister climatique
77 Wellesley Street West 11th Floor Ferguson Block Bureau du ministre Toronto ON M7A 2T5 Tel Fax
416-314-6790 416-314-6748 77 rue Wellesley Ouest
11e eacutetage edifice Ferguson Toronto ON M7A 2T5 Teacutel 416-314-6790 Teacuteleacutec 416-314-6748
Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
FOREWORD
This document ldquoTechnical Standards to Manage Air Pollution February 27th 2018 version 51rdquo (the Technical Standards publication) sets out the requirements that facilities must follow if they are registered for a technical standard As per section 38 of Ontario Regulation 41905 Air Pollution - Local Air Quality a technical standard can be either an industry standard or an equipment standard All technical standards will be made available through a website maintained by the Ministry of the Environment and Climate Change on the Internet and through the Ministryrsquos Public Information Centre
The Technical Standards publication will include both industry standards and equipment standards It will specify the classes of facilities the technical standard applies to with reference to the North American Industry Classification System (NAICS) codes the contaminants the technical standard applies to the steps that shall be taken to comply with the technical standard and the time periods within which the steps shall be taken It will describe requirements relating to technology to be used at the facility the operation of the facility the monitoring and reporting of information relating to the facility and any other related matter In the event of a conflict between this document and the references to sections in O Regulation 41905 the language in O Regulation 41905 shall be used
The contents of this document may also be updated from time to time Any changes will be based upon public consultation consistent with the Ontario Environmental Bill of Rights legislation All web site addresses referred to in this document were current at the time of release
For any addenda or revisions to the Technical Standards publication please visit the MOECC website or contact
Ontario Ministry of the Environment and Climate Change Environmental Assessment and Permissions Branch 40 St Clair Avenue West 7th Floor Toronto Ontario M4V 1M2
Telephone (416) 327-5519 Fax (416) 327-2936
Ontario Ministry of the Environment and Climate Change i
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Table of Contents
TECHNICAL STANDARDS TO MANAGE AIR POLLUTION
FOREWORD i
11 INTRODUCTION 1
12 Industry Standards 313 Equipment Standards 414 Combination of industry standards and equipment standards 415 Updating of Technical Standards 5
20 FOUNDRIES ndash INDUSTRY STANDARD 6
30 FOREST PRODUCTS ndash INDUSTRY STANDARD73
40 PULP AND PAPER ndash INDUSTRY STANDARD87
50 METAL FINISHERS ndash INDUSTRY STANDARD156
60 PETROLEUM REFINING ndash INDUSTRY STANDARD187
70 PETROCHEMICAL ndash INDUSTRY STANDARD 239
Appendix A Record of Publications292
Ontario Ministry of the Environment and Climate Change ii
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
CHAPTER 1 INTRODUCTION
Ontario Regulation 41905 Air Pollution ndash Local Air Quality (the Regulation or O Reg 41905) made under the Environmental Protection Act (EPA) is the regulation that is intended to protect communities against adverse effects from local sources of air emissions The Regulation places limits on the concentration of contaminants in the natural environment that are caused by emissions from a facility Under certain conditions the Regulation also allows for a person to register for a technical standard in respect of a facility for certain contaminants as identified in this Technical Standards publication document Registering for and complying with a technical standard is an alternative to complying with the air standards that are based on contaminant concentrations
This Technical Standards publication is published under the authority of section 38 of the Regulation
Technical Standards publication - O Reg 41905 s 38
38 (1) The Minister shall ensure that with respect to the Technical Standards publication all of the following criteria are met
1 Every technical standard set out in the Technical Standards publication is specifically identified in thepublication as an industry standard or an equipment standard
2 For each industry standard that is set out in the Technical Standards publicationi the Technical Standards publication specifies which classes of facilities the industry
standard applies to and those classes are identified with reference to NAICS codesii the Technical Standards publication specifies which contaminants the industry standard
applies toiii the Technical Standards publication sets out the steps that shall be taken to comply with the
industry standard andiv the Technical Standards publication sets out the time periods if any within which the steps
specified under subparagraph iii shall be taken3 The Technical Standards publication indicates that with respect to each class specified under
subparagraph 2 i to which an industry standard applies and with respect to at least one contaminantto which that standard applies the Minister is of the opinion that
i with respect to at least two facilities in the class that are located in OntarioA it is not technically feasible to comply with section 19 or 20 whichever is applicable orB it is not economically feasible to comply with section 19 or 20 whichever is applicable
ii compliance in accordance with subsection 42 (5) with the industry standard that applies tothe class and the contaminantA is technically and economically feasible with respect to at least one facility in the class
that is located in Ontario and
B will permit efforts that would otherwise be made to comply with section 19 or 20 to be putto better use to protect the natural environment having regard to subparagraph I
iii including the industry standard that applies to the class and the contaminant in theTechnical Standards publication is more efficient than having the Director consider separaterequests under section 32 for approval of alterations to the standard for the contaminant thatwould otherwise apply to facilities in the class
Ontario Ministry of the Environment and Climate Change 1
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
4 For each equipment standard that is set out in the Technical Standards publicationi the Technical Standards publication specifies which classes of facilities the equipment
standard applies to and those classes are identified with reference to NAICS codesii the Technical Standards publication specifies which contaminants the equipment standard
applies toiii the Technical Standards publication specifies which sources of contaminant the
equipment standard applies toiv the Technical Standards publication sets out the steps that shall be taken to comply with
the equipment standard andv the Technical Standards publication sets out the time periods if any within which the
steps specified under subparagraph iv shall be taken5 The Technical Standards publication indicates that with respect to each class specified under
subparagraph 4 i to which a equipment standard applies and with respect to at least onecontaminant and source of contaminant to which that standard applies the Minister is of theopinion that
i at least two facilities in the class that are located in Ontario have the source ofcontaminant and
ii compliance in accordance with subsection 43 (4) with the equipment standard thatapplies to the class the contaminant and the source of contaminant is technically andeconomically feasible with respect to at least one facility in the class that is located inOntario
(2) Before a technical standard is set out in the Technical Standards publication the Minister shallconsider whether provisions dealing with the following matters should be included in thetechnical standard
1 Notification of and consultation with affected persons before making an application forregistration in respect of the technical standard
2 The making and retention of records3 Circumstances in which notice is required to be given to the Ministry4 Progress reports relating to implementation of the technical standard
(3) Before an industry standard that applies to a class of facilities is set out in the TechnicalStandards publication the Minister shall consider whether compliance in accordance withsubsection 42 (5) with the industry standard may reduce the regulatory burden applicable tofacilities in that class for which compliance with section 19 or 20 would otherwise be required
(4) Before an equipment standard that applies to a class of facilities and a source of contaminant isset out in the Technical Standards publication the Minister shall consider whether compliancein accordance with subsection 43 (4) with the equipment standard may reduce the regulatoryburden applicable to facilities in that class for which consideration of the source of contaminantwould otherwise be necessary when using an approved dispersion model for the purposes ofthis Part
A facility may be registered for an industry standard an equipment standard or a combination of industry standard and equipment standard A brief description of these technical standards is provided below For more information please refer to the Regulation
Ontario Ministry of the Environment and Climate Change 2
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
11 Industry Standards
In general a person is exempt from Part II of the Regulation for a contaminant if the person is registered with respect to a sufficient number of industry standards to address all sources of that contaminant at their facility Subsections 42(1) and (2) provide that
42 (1) Subject to subsection (2) this Part except for this section and sections 24 271 and 38 to 41does not apply to a person in respect of a facility and contaminant if one or more industry standards set out in the Technical Standards publication apply to the facility and the contaminant and
(a) the facility is part of only one class identified by a NAICS code and the person isregistered on the Ministryrsquos Technical Standards Registry ndash Air Pollution in respect of allof the industry standards that apply to the facility and the contaminant or
(b) the facility is part of two or more classes that are identified by NAICS codes industrystandards apply to all of those classes and to the contaminant and the person isregistered on the Ministryrsquos Technical Standards Registry ndash Air Pollution in respect of allof those industry standards
(2) This Part applies for the purpose of determining whether the Director may give a person a noticeunder section 24 or 271 and for the purpose of preparing a report required by a notice undersection 24 or 271
In other words if all of the sources of a contaminant at that facility are addressed in one or more industry standards and that facility is registered for all of the industry standards then that facility is exempt from the air standards in Schedules 2 or 3 of O Reg 41905 for the contaminant(s) for which the person is registered for in respect of the facility As such it is not necessary for such a facility to assess any other sources of the contaminant(s) for which the facility is registered
If a person is registered for an industry standard(s) in respect of a facility and a contaminant but all sources of the contaminant at the facility are not addressed by the industry standard(s) (ie there are sources of contaminant at the facility that are part of another NAICs code) the person may exclude the sources of contaminant that are associated with the NAICS code addressed in the industry standard when modelling under the Regulation Section 42(4) provides
42 (4) A person who uses an approved dispersion model for the purposes of this Part in respect of a facility and a contaminant is not required to consider a source of contaminant that discharges the contaminant if
(a) subsection (1) does not apply to the person in respect of the facility and the contaminant
(b) the source of contaminant is in a part of the facility that is a part of a class of facilities towhich an industry standard applies in respect of the facility and the contaminant and
(c) the person is registered on the Ministryrsquos Technical Standards Registry ndash Air Pollution inrespect of the industry standard facility and contaminant
Ontario Ministry of the Environment and Climate Change 3
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
12 Equipment Standards
In general a person is exempt from Part II of the Regulation for a contaminant if the person is registered with respect to a sufficient number of equipment standards to address all sources of that contaminant at their facility Section 43(1) and (2) provide that
43 (1) Subject to subsection (2) this Part except for this section and sections 24 271 and 38 to 41 does not apply to a person in respect of a facility and contaminant if
(a) equipment standards set out in the Technical Standards publication apply to everysource of the contaminant in the facility and
(b) the person is registered on the Ministryrsquos Technical Standards Registry ndash Air Pollution inrespect of the facility the contaminant and every equipment standard that applies to asource of contaminant in the facility
(2) This Part applies for the purpose of determining whether the Director may give a person a noticeunder section 24 or 271 and for the purpose of preparing a report required by a notice undersection 24 or 271
However if an equipment standard or combination of equipment standards does not address all sources of contaminants from that facility then a person who uses an approved dispersion model for the purposes of Part II of the Regulation in respect of a facility and a contaminant is not required to consider the source of contaminant referenced in the equipment standard(s) for which the person is registered Section 43(3) of the Regulation provides
43 (3) A person who uses an approved dispersion model for the purposes of this Part in respect of a facility and a contaminant is not required to consider a source of contaminant that discharges the contaminant if
(a) subsection (1) does not apply to the person in respect of the facility and the contaminant
(b) an equipment standard set out in the Technical Standards publication applies to thefacility the contaminant and the source of contaminant and
(c) the person is registered on the Ministryrsquos Technical Standards Registry ndash Air Pollution inrespect of the equipment standard facility contaminant and source of contaminant
13 Combination of industry standards and equipment standards
In general a person is exempt from Part II of the Regulation for a contaminant if the person is registered with respect to a combination of one or more industry standards and one or more equipment standards such that all sources of that contaminant at their facility are addressed Section 44(1) and (2) provide that
Ontario Ministry of the Environment and Climate Change 4
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
44 (1) Subject to subsection (2) this Part except for this section and sections 24 271 and 38 to 41does not apply to a person in respect of a facility and contaminant if
(a) the person is registered on the Ministryrsquos Technical Standards Registry ndash Air Pollution inrespect of one or more industry standards the facility and the contaminant
(b) there is one or more sources of contaminant in a part of the facility that is not part of aclass of facilities to which any of the industry standards referred to in clause (a) applyand
(c) with respect to each source of contaminant to which clause (b) applies the person isregistered on the Ministryrsquos Technical Standards Registry ndash Air Pollution in respect of anequipment standard the facility the contaminant and the source of contaminant
(2) This Part applies for the purpose of determining whether the Director may give a person a noticeunder section 24 or 271 and for the purpose of preparing a report required by a notice undersection 24 or 271
In other words if all of the sources of a contaminant at that facility are addressed in one or more industry standards and one or more equipment standards and that facility is registered for all of those industry and equipment standards then that facility is exempt from the air standards in Schedules 2 or 3 of O Reg 41905 for the contaminant(s) for which the person is registered for in respect of the facility As such it is not necessary for such a facility to assess any other sources of the contaminant(s) for which the facility is registered
14 Updating of Technical Standards
Part IV (Application for Review) of the Environmental Bill of Rights (EBR) gives the people of Ontario a formal process for proposing that an existing policy Act regulation or instrument of Ontario should be reviewed changed or improved in order to protect the environment A person may also ask the government to consider establishing new ones Under this authority any two people may request the Minister to review a technical standard The following are factors that could be considered in making this request
1 The length of time the technical standard has been in place
2 New technically andor economically feasible options that have become commerciallyavailable
3 Any new scientific information relating to the nature of any contaminant to which thetechnical standard applies
For more information on how to request a review please go to httpwwwecoonca
Ontario Ministry of the Environment and Climate Change 5
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
CHAPTER 2 - FOUNDRIES ndash INDUSTRY STANDARD
Version 20 Created March 8 2016
Preamble
bull This technical standard is an industry standard as defined in section 1 of O Reg41905
bull With respect to facilities this industry standard applies to every facility that is part of aclass identified by NAICS code 3315 (Foundries) Facilities in this class include 33151(Ferrous Metal Foundries) 331511 (Iron Foundries) 331514 (Steel Foundries) 33152(Non-ferrous Metal Foundries) 331523 (Non-ferrous Die-casting Foundries) and 331529(Non-ferrous Foundries (except Die-casting)) but do not include secondary lead smelters
bull With respect to contaminants this standard applies to contaminants listed in Appendix2 - 1
bull Each source of contaminant associated with NAICS code 3315 that discharges acontaminant mentioned in the above bullet has been considered in development of thisindustry standard As such a person that meets the criteria set out in subsection 42 (1)or subsection 44 (1) of O Reg 41905 is in general exempt from Part II of theRegulation in respect of the facility and contaminant(s) for which it is registered In otherwords there is no need to model in a facilityrsquos Emission Summary and DispersionModelling report discharges of a registered contaminant from any source ofcontaminant associated with NAICS code 3315 (For more information please see theIntroduction to the Technical Standards Publication)
bull In accordance with subsection 38 (3) of O Reg 41905 compliance with this industrystandard in accordance with subsection 42 (5) or subsection 44 (3) may reduce theregulatory burden applicable to facilities in this class
bull This standard contains requirements that relate to a source of contaminant that is part ofone or more of the following processes
bull a metal melting processbull a furnace tapping processbull a molten metal pouring processbull a casting cooling processbull a process that involves trimming grinding cutting finishing or media
blasting of castingsbull a sand reclamation processbull a materials handling process ndash scrap charge sand slag and molten
metal handling processes and material storage are considered to bematerials handling processes
bull a mold production process (hot box and warm box)bull a core production process (shell core and cold box)bull a casting process including a cooling breakout and shakeout processbull a process that involves using a torch to cut metalbull a liquid spray coating process
Ontario Ministry of the Environment and Climate Change 6
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
bull For this industry standard with respect to lead and lead compounds and suspendedparticulate matter the publication of this industry standard indicates that the followingcriteria of paragraph 3 of subsection 38 (1) of O Reg 41905 are met(a) with respect to at least two facilities located in Ontario to which this standard appliesit is not economically feasible to comply with section 19 or 20 of O Reg 41905whichever is applicable(b) compliance in accordance with subsection 42 (5) of O Reg 41905 with thisstandard
(i) is technically and economically feasible with respect to at least one facilitylocated in Ontario to which this industry standard applies and
(ii) will permit efforts that would otherwise be made to comply with section 19 or20 of O Reg 41905 to be put to better use to protect the naturalenvironment having regard to clause (a) and
(iii) including this industry standard in the ldquoTechnical Standards to Manage AirPollutionrdquo is more efficient than having the Director consider separaterequests under section 32 of O Reg 41905 to set site-specific standards forthe contaminant that would otherwise apply to facilities in the class
Ontario Ministry of the Environment and Climate Change 7
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
CONTENTS1 Definitions2 Application21 Transition3 Reduction of priority metals4 Operational practices ndash minimization of SPM from roadways and indoor and outdoor
material handling processes41 Operational practices ndash minimization of SPM from foundry processes that operate
outdoors 5 Reducing fugitive emissions51 Ventilation program52 Volumetric flow rates in and out of the building areas53 Building differential pressure54 Change management ndash proposed changes to ventilation55 Multi-tenant buildings ndash SPM6 Ventilation assessment ndash optimizing capture of lead61 Notice ndash ventilation assessment report ndash optimizing capture7 Ventilation and pollution control ndash optimizing capture of lead8 Ventilation and pollution control ndash optimizing capture of SPM ndash new or modified facilities9 Ventilation and pollution control ndash optimizing capture of lead ndash new or modified facilities91 Vertical and unimpeded discharges10 Coke-fired cupola furnaces101 Thermal sand reclaimers ndash chlorinated or fluorinated compounds102 Thermal sand reclaimers ndash VOCs103 Thermal sand reclaimers ndash SPM104 Thermal oxidizers ndash temperature and residence time105 Catalytic oxidizers ndash temperature and residence time106 Liquid spray coating process107 Electric arc furnace or argon oxygen decarburizer108 Pollution control ndash torch cutting metal to charge a furnace109 Pollution control ndash aluminum reverberatory furnace ndash scrap metal11 Operating Parameter Summary Table111 Measurement of operating parameters112 Deviations from operating parameters113 Notification of deviations from operating parameters114 Phase-in for new air pollution control devices115 Inspection and maintenance table116 Inspection and maintenance activities117 Deviations ndash inspection and maintenance118 Recurring malfunctions12 Operational practices ndash minimization of VOCs13 Pollution control ndash minimization of total amines14 Operational practices ndash minimization of sulphur dioxide15 Pollution control ndash minimization of sulphur dioxide16 Complaint procedure17 Identifying managed sources171 Requirement to continue the management of sources172 Changes to managed sources173 Specified management of sources174 Notification of changes to management of sources
Ontario Ministry of the Environment and Climate Change 8
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
18 Summary reports19 Records
APPENDIX 2-1 All Contaminants APPENDIX 2-2 Priority Metals APPENDIX 2-3 Suspended Particulate Matter APPENDIX 2-4 Volatile Organic Compounds APPENDIX 2-5 Hydrogen Chloride and Fluorides (as HF) APPENDIX 2-6 Amines APPENDIX 2-7 Sulphur Dioxide APPENDIX 2-8 Lead and Lead Compounds
Ontario Ministry of the Environment and Climate Change 9
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Definitions 1 (1) For the purposes of this industry standard for foundry facilities
ldquoActrdquo means the Environmental Protection Act ldquoair pollution control devicerdquo means a device that removes contaminants from a gaseous stream
and includes electrostatic precipitators wet scrubbers lime scrubbers baghouses cyclones adsorption systems thermal oxidizers catalytic oxidizers and afterburners
ldquoadsorption systemrdquo means a technology where a pollutant is adsorbed on the surface (mostly the internal surface) of a granule bead or crystal of adsorbent material Typically fixed beds of adsorbents such as activated carbon are used to remove VOCs
ldquoafterburnerrdquo means a device in which combustible waste gases pass over or around a burner flame where oxidation of the waste gases is furthered
ldquobag leak detection systemrdquo means a system that detects leaks in a baghouse and includes systems that measure pressure drop opacity or an electrical signal to detect leaks
ldquobaghouserdquo means a device that uses fabric bags or cartridge filters to remove particulate from a gaseous stream prior to its discharge into the air
ldquoblock averagerdquo means an average of the values measured during a discrete block of time that does not consider measurements before or after that time period For example a 30-minute block average calculated from 431 pm to 500 pm would not consider any values from 401pm to 430pm
ldquobuilding differential pressurerdquo means the difference between the pressure measured inside a facility building and the pressure measured outside of the facility building
ldquoCAS Nordquo has the same meaning as in subsection 1 (1) of O Reg 41905 ldquocatalytic oxidizerrdquo means a technology that passes a gas over a support material coated with a
catalyst that promotes oxidation of organic material in the gas ldquocoke-fired cupola furnacerdquo means a coke-fired continuous type furnace generally used as a
melt furnace ldquocold boxrdquo means a technology that uses cold setting resins that include the addition of a
gaseous catalyst such as sulphur dioxide ldquocold setting resinsrdquo means resins that cure at ambient temperatures and include resins that
may require the addition of a catalyst to cure at ambient temperatures ldquocupola afterburnerrdquo means an afterburner that treats combustion gases from a cupola furnace ldquoDistrict Managerrdquo means the District Manager of the appropriate local district office of the
Ministry where the foundry facility is geographically located ldquoexisting foundry facilityrdquo means a foundry facility
(a) the construction of which was completed or began on or before February 1 2010 or(b) for which an application was made on or before February 1 2010 for a certificate of
approval in respect of the facilityldquofoundry facilityrdquo means a facility at which molten metal is poured into a mold or die to form a
casting and that is part of a class identified by NAICS code 3315 and includes a ferrous metal foundry facility iron foundry facility steel foundry facility non-ferrous metal foundry
Ontario Ministry of the Environment and Climate Change 10
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
facility non-ferrous die-casting foundry facility and non-ferrous foundry facilities (except die-casting) and does not include secondary lead smelters
ldquogeneral exhaust ventilationrdquo means an opening in a building designed to exhaust directly from the building into the air For the purpose of this industry standard general exhaust ventilation excludes a washroom fan
ldquohighest-ranking individualrdquo means the most senior individual at a foundry facility who has management responsibilities relating to the facility
HVLP spray equipment means high volume low pressure spray equipment that (a) bears a permanent label identifying the piece of equipment as HVLP spray equipment or
is otherwise identifiable as HVLP spray equipment(b) is used to apply coating at a high volume and under low pressure and(c) is designed and operated with an atomizing air pressure between 01 and 10 pounds per
square inch as measured at the centre of the air cap and the centre of the air cap hornsldquoindustry standardrdquo has the same meaning as in subsection 1 (1) of O Reg 41905 ldquolocal exhaust ventilation systemrdquo means a system used to capture a contaminant at or near the
point where the contaminant is generated and may be composed of one or more of the following pieces of equipment a hood blast gate ductwork damper and fan
ldquomajor modificationrdquo means any modification made to a foundry facility that involves adding or replacing a source of contaminant that is part of one or more of the following processes 1 A metal melting process2 A furnace tapping process3 A molten metal pouring process4 A casting cooling process5 A process that involves trimming grinding cutting finishing or media blasting of
castings6 A sand reclamation process7 A breakout or shakeout process
ldquomake-up air unitrdquo means equipment used to supply air into a building or an area of a building in a controlled manner
Minister means the Minister of the Environment and Climate Change or such other member of the Executive Council as may be assigned the administration of this Act under the Executive Council Act
Ministry means the ministry of the Minister ldquoNAICSrdquo has the same meaning as in subsection 1 (1) of O Reg 41905 ldquonaphthalene depleted solvent resinrdquo means a resin where the maximum naphthalene
(CAS91-20-3) concentration within the solvent fraction is less than three per cent ldquonew foundry facilityrdquo means a foundry facility the construction of which began after February 1
2010 and no application was made on or before that day for a certificate of approval in respect of the facility
Ontario Ministry of the Environment and Climate Change 11
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
ldquonon-ferrous metal foundry facility that uses leadrdquo means a foundry facility that uses non-ferrous metal to form castings and is part of a class identified by NAICS code 33152 and uses raw materials containing greater than 02 per cent by weight of lead and lead compounds
ldquoO Reg 41905rdquo means Ontario Regulation 41905 (Air Pollution ndash Local Air Quality) made under the Act
ldquopriority metalrdquo means a contaminant listed in Appendix 2-2 ldquoraw materialrdquo means an ingredient that is used in the production of castings and includes
incoming scrap ldquorecordrdquo includes a written procedure a measurement result a written notification a table a
report a document information provided to the highest-ranking individual for review a written practice anything required by this industry standard to be recorded and an update to any of the preceding
ldquoregistered contaminantrdquo means a contaminant that may be discharged into the air from a foundry facility if a person is registered in respect of this industry standard the facility and the contaminant
ldquoregistered personrdquo means a person that is registered on the Ministryrsquos Technical Standards Registry ndash Air Pollution in respect of this industry standard a foundry facility and one or more contaminants listed in Appendix 2-1
ldquoregistrationrdquo means registration on the Ministryrsquos Technical Standards Registry ndash Air Pollution in respect of this industry standard
ldquoSPMrdquo means suspended particulate matter that has a diameter of less than 44 microns and includes the contaminants that are listed in Appendix 2-3
ldquospray boothrdquo means a structure used for coating operations by spray application and incorporating the capability of entrapping and capturing coating overspray
ldquostatic pressurerdquo means pressure exerted by a gas For example when a gas is flowing static pressure is measured perpendicular to the direction of flow and when a gas is at rest static pressure is the pressure exerted in all directions by the gas
ldquosulphur dioxiderdquo means the contaminant that has a CAS No of 7446-09-5 ldquotechnical standardrdquo has the same meaning as in subsection 1 (1) of O Reg 41905 ldquothermal oxidizerrdquo means a technology where combustible waste gases pass over or around a
burner flame into a residence chamber where oxidation of the waste gases is completed ldquoVOCsrdquo means volatile organic compounds and includes the contaminants that are listed in
Appendix 2-4 ldquoventilation coordinatorrdquo means an individual appointed in writing by a registered person who
has a level of authority adequate to be responsible for the design installation modification operation and maintenance requirements related to optimizing the capture of contaminants by the ventilation systems at a foundry facility
ldquowet scrubberrdquo means a device that uses a scrubbing liquid to remove contaminants from a gaseous stream prior to its discharge into the air
(2) In this industry standard a reference to the Director means(a) the Director appointed under section 5 of the Act in respect of the section of this
industry standard in which the reference appears or
Ontario Ministry of the Environment and Climate Change 12
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(b) if no Director described in clause (a) has been appointed in respect of a section ofthis industry standard any Director appointed under section 5 of the Act in respect ofsection 271 or paragraph 3 of subsection 11 (1) of O Reg 41905
Application 2 (1) This industry standard applies in accordance with subsections (2) and (4) to a
person who is registered on the Ministryrsquos Technical Standards Registry ndash Air Pollution in respect of
(a) this industry standard(b) a foundry facility and(c) one or more of the contaminants listed in Appendix 2-1
(2) If the person mentioned in subsection (1) is registered with respect to a facility type setout in Column 1 of Table 2-2 and one or more of the contaminants listed in an Appendix set out opposite the facility in Column 2 of Table 2-2 the sections set out opposite the Appendix in Column 3 of Table 2-2 apply in respect of the person
(3) For greater clarity(a) the contaminants listed in Appendix 2-2 to 2-8 are also listed in Appendix 2-1(b) the contaminants listed in Appendix 2-2 are also listed in Appendix 2-3(c) the contaminants listed in Appendix 2-8 are also listed in Appendix 2-2 and 2-3 and(d) the contaminants listed in Appendix 6 are also listed in Appendix 2-4
(4) Subject to section 21 a person mentioned in subsection (1) is required to comply withthe sections of this industry standard that apply to the person in accordance with subsection (2) on or before the date the person registers on the Ministryrsquos Technical Standards Registry ndash Air Pollution unless a different date is specified in this industry standard
TABLE 2-2 Application
Item Column 1 Facility Type
Column 2 Appendix
Column 3 Applicable Sections
1 Foundry facility Appendix 2-1 1 2 21 51 52 53 54 61 91 10 11except for 11 (5) and 11 (9) 111 112 114 to 118 16 to 19
2 Foundry facility Appendix 2-2 3
3 Foundry facility Appendix 2-3 4 41 5 55 8 103 107 108 109
4 Foundry facility Appendix 2-4 102 104 105 106 11 (5) (b) 113 12
5 Foundry facility Appendix 2-5 101 11 (5) (b) 113
6 Foundry facility Appendix 2-6 13
7 Foundry facility Appendix 2-7 11 (5) (b) 113 14 15
8 Non-Ferrous Metal Foundry Facility That Uses Lead
Appendix 2-8 6 7 9 11 (5) (a) and 11 (9) 113
Transition 21 (1) For the purposes of this section
ldquotransition periodrdquo means the period that is after March 8 2016 and before March 8 2017 (2) Subject to subsections (3) and (5) subsection 2 (4) does not apply during the transition
period
13Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(3) Subsection (2) does not apply in respect of a registered contaminant listed in anAppendix set out in Column 2 of Table 2-21 and a section set out in Column 1 of Table 2-21 if prior to March 8 2016 a person is registered for the contaminant
(4) Subsection 2 (4) does not apply to a person mentioned in subsection (3) during thetransition period if the person complies with the section set out in Column 3 of Table 2-21 opposite the section mentioned in subsection (3) set out in Column 1 of Table 2-21
(5) Subsection (2) does not apply with respect to this section and section 2
TABLE 2 ndash 21 Transition
Item Column 1 Section in industry standard published [March 2016]
Column 2 Appendix
Column 3 Section in industry standard published in December 2009
1 3 Appendix 2-2 3 2 4 Appendix 2-3 4 3 5 51 to 53 Appendix 2-3 5 4 54 Appendix 2-3 2-4 or 2-7 17 (3) to 17 (5) 5 6 Appendix 2-8 6 6 7 Appendix 2-8 7 7 8 Appendix 2-3 8 8 9 Appendix 2-8 9 9 10 Appendix 2-1 10 10 11 to 114 Appendix 2-1 11 and 18 (3) 11 115 to 118 Appendix 2-1 11 12 12 Appendix 2-4 12 13 13 Appendix 2-6 13 14 14 Appendix 2-7 14 15 15 Appendix 2-7 15 16 16 Appendix 2-1 16 17 17 to 174 Appendix 2-1 17 (1) and (2) 18 18 Appendix 2-1 18 19 19 Appendix 2-1 19
Reduction of priority metals 3 (1) If a registered contaminant listed in Appendix 2-2 may be discharged into the air
from a foundry facility the registered person shall ensure that a written procedure is developed and implemented to reduce where feasible the weight percent of each registered contaminant listed in Appendix 2-2 in raw materials and products
(2) Where appropriate the procedure mentioned in subsection (1) shall include arequirement to offer customers products that contain less of a registered contaminant listed in Appendix 2-2 than other commercially available similar products
Operational practices ndash minimization of SPM from roadways and indoor and outdoormaterial handling processes
4 (1) A registered person shall ensure that a written procedure is developed andimplemented in accordance with good engineering practices to minimize the discharge of registered contaminants listed in Appendix 2-3 from each roadway at the foundry facility and each source of contaminant that is part of one or more of the following processes
1 An incoming scrap handling process
Ontario Ministry of the Environment and Climate Change 14
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
2 A charge handling process3 A sand handling process4 A slag handling process5 Other materials handling processes such as material storage and molten metal
handling(2) The procedure mentioned in subsection (1) shall where appropriate include
(a) methods to minimize the discharge of fugitive dust from roadways includingmethods to ensure
(i)vehicles travel at low speeds on roads at the foundry facility(ii) signs that clearly display the low speed limits mentioned in subclause (i) are
posted(iii) frequently used unpaved roads are graded with large aggregate or gravel(iv) paved roads are cleaned on a regular basis and(v) water or other dust suppressant is used on unpaved roads at the foundry
facility on a regular basis(b) methods to minimize the discharge of fugitive dust from outdoor storage piles
including methods to ensure(i) barriers are placed around outdoor storage piles(ii) covers are placed on top of outdoor storage piles(iii) fine materials are removed from materials prior to storing outdoor and(iv) water or other dust supressant is used on outdoor storage piles as
necessary to maintain adequate moisture(c) methods to minimize the discharge of fumes during molten metal handling including
during the transfer of molten metal from one vessel to another including methods toensure that
(i) fumes are minimized by ensuring that molten metal is poured at the lowestfeasible temperature
(ii) ladle covers are used when holding ladles of molten metal and whenmoving ladles of molten metal to a pouring area and
(iii) molten metal is poured carefully and(d)general good housekeeping practices
Operational practices ndash minimization of SPM from foundry processes that operate outdoors
41 (1) Subject to subsection (4) a registered person shall ensure that written procedures are developed and implemented in accordance with good engineering practices to minimize the discharge of a registered contaminant listed in Appendix 2-3 from a source of contaminant that is part of one or more of the following processes during any period when the source of contaminant is operated outside of an enclosed structure
1 A molten metal pouring process2 A casting cooling process in which the casting is confined within a mold3 A breakout process4 A process that involves trimming grinding cutting finishing or media blasting of
castings(2) The procedures mentioned in subsection (1) shall
(a) identify each process mentioned in subsection (1) carried out at the foundry facility inwhich a source of contaminant may be operated outside of an enclosed structure
(b) describe steps to be taken to ensure that each source of contaminant mentioned inclause (a) is operated inside an enclosed structure if feasible
Ontario Ministry of the Environment and Climate Change 15
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(c) include methods to minimize discharges associated with molten metal pouringincluding where appropriate methods to ensure that molten metal is pouredcarefully
(d) include methods to minimize discharges associated with cooling including whereappropriate methods to ensure that where a cooling canopy is unavailable a castingthat is cooling in a mold is left undisturbed until cool to minimize fugitive emissionsand
(e) describe steps to be taken after a source of contaminant has been operated outsideof an enclosed structure to ensure that the operational area is returned to a state ofcleanliness
(3) If a source of contaminant mentioned in subsection (1) is located outside of an enclosedstructure the registered person shall ensure that the following information is recorded
1 An identification of the source of contaminant that was operated outside of anenclosed structure
2 The date time and duration that the source of contaminant was operated outside ofan enclosed structure
3 The reason that the source of contaminant was operated outside of an enclosedstructure during the period of time mentioned in paragraph 2
4 A description of any steps taken to prevent or minimize the discharge of a registeredcontaminant listed in Appendix 2-3 into the air during the period of time mentioned inparagraph 2
(4) The requirement in subsection (1) to develop and implement written procedures doesnot apply with respect to a source of contaminant that is operated inside a structure comprised of three walls and a roof
Reducing fugitive emissions 5 (1) A registered person shall ensure that a written procedure is developed and
implemented to ensure that fugitive emissions of a registered contaminant listed in Appendix 2-3 are reduced from the following processes
1 A metal melting process2 A furnace tapping process3 A molten metal pouring process4 A casting cooling process5 A breakout or shakeout process6 A process that involves trimming grinding cutting finishing or media blasting of
castings(2) A procedure mentioned in subsection (1) relating to a process set out in paragraph 1 of
that subsection shall include where appropriate practices to ensure that molten metal in furnaces is covered with ceramic blankets or protective atmosphere
(3) A procedure mentioned in subsection (1) relating to a process set out in paragraph 3 ofthat subsection shall include where appropriate practices to ensure empty ladles are covered or stored upside down
(4) For greater clarity subsection (1) applies to a person registered in respect of lead andlead compounds
Ventilation program 51 (1) A registered person shall appoint a ventilation coordinator and ensure that the
ventilation coordinator develops and implements a ventilation program in accordance with this section
(2) For the purpose of the ventilation program one of the following actions shall be takenOntario Ministry of the Environment and Climate Change 16
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 1 A table is prepared in accordance with section 522 Measurements are taken in accordance with section 53
(3) The following information shall be recorded as part of the ventilation program1 A description of each ventilation system at the foundry facility2 For each ventilation system described for the purposes of paragraph 1 the
specifications of each fan in the system including the volumetric flow rate of the fan3 A process flow diagram of each ventilation system described for the purposes of
paragraph 1 drawn to scale that includes the following informationi Each piece of equipment from which emissions may be captured by the
ventilation systemii Each air pollution control device associated with a piece of equipment
mentioned in subparagraph iiii Key information about the ventilation system including volumetric flow
rates4 A drawing of each ventilation system described for the purposes of paragraph 1 that
reflects as-built condition The drawing shall be based on the specifications of thesystem that was installed not the design specifications
5 One of the followingi A table prepared in accordance with section 52ii Each block average recorded in accordance with section 53
6 For each 30-minute block average mentioned in subparagraph 5 ii that is positiveand for which an operational adjustment is required by subsection 7 (3)
i the date and time that the 30-minute block average of building differentialpressure was positive
ii the measured values of the building differential pressure expressed in 30shyminute block averages taken during the time that the area was positivelypressured
iii an explanation of the suspected cause of the positive pressureiv a description of the operational adjustments required to be made under
subsection 7 (3) and the date each operational adjustment was completedand
v the position title of personnel who assigned a person to make anoperational adjustment mentioned in subsection 7 (3)
(4) A ventilation system mentioned in subsection (3) includes general exhaust ventilation alocal exhaust ventilation system and an make-up air unit but does not include a ventilation system contained wholly within an area that is isolated from foundry processes
Volumetric flow rates in and out of the building areas 52 The table mentioned in paragraph 1 of subsection 51 (2) shall set out for each area of
the foundry facility in which a foundry process is enclosed the following information in the manner illustrated by Table 2-52
1 Each make-up air unit in the area shall be listed in Column 1 of the table2 Opposite each make-up air unit mentioned in paragraph 1 the volumetric flow rate
of the unit shall be set out in Column 2 of the table3 Each local exhaust ventilation system and each general exhaust ventilation in
the area shall be listed in Column 3 of the table4 Opposite each ventilation system mentioned in paragraph 3 the flow rate of
the ventilation system shall be set out in Column 4 of the table5 The sum of the flow rates listed in Column 2 of the table shall be set out in the
last row of Column 26 The sum of the flow rates listed in Column 4 of the table shall be set out in the
last row of Column 47 The table shall contain an indication of whether the sum mentioned in
Ontario Ministry of the Environment and Climate Change 17
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 paragraph 5 is greater than the sum mentioned in paragraph 6
TABLE 2-52 Volumetric flow rates in and out of the building areas
Item Column 1 Make-up Air Units
Column 2 Volumetric Flow Rate
Column 3 Local Exhaust Ventilation Systems and General Exhaust Ventilation
Column 4 Volumetric Flow Rate
1 2 3
Total Flow Rate Entering Enclosed Area Total Flow Rate Exiting Enclosed Area
Building differential pressure 53 (1) The measurements required to be taken by paragraph 2 of subsection 51 (2)
shall be taken by continuously measuring the building differential pressure for each area that contains a pouring operation or a melt furnace and recording the building differential pressure in 30-minute block averages
(2) Each measurement required by subsection (1) shall be taken by at least twomonitors that in the opinion of the Director accurately measure the building differential pressure
(3) For greater clarity at least one monitor required by subsection (2) shall belocated inside the building and at least one monitor shall be located outside of the building
(4) In determining whether the monitors mentioned in subsection (2) accuratelymeasure building differential pressure the Director shall consider the following information
1 The number of monitors used to take the measurements2 The location of each monitor3 The frequency of measurement4 The wind rose or predominant wind direction5 The configuration of the building6 The roof heights of the building
(5) The location of each monitor required by subsection (2) shall be depicted in adiagram drawn to scale of the foundry facility
(6) If a change is proposed that would alter the information contained in thediagram required by subsection (5) the diagram shall be updated with the proposed change and submitted to the Director no later than 60 days before the proposed change occurs
Change management - proposed changes to ventilation 54 (1) Subject to subsection (5) prior to implementing any change to a ventilation
system at a foundry facility a registered person shall ensure that the following information is recorded
1 A description of the proposed change to the ventilation system2 An evaluation of the possible impacts of the proposed change to the ventilation
system on the ability of the ventilation system to capture contaminants underanticipated operating scenarios
3 An evaluation of the impact of the proposed change to the ventilation system on the
18Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 balance of volumetric flow rates entering and exiting the enclosed area in which the ventilation system is located The evaluation may be based on information such as an analysis of volumetric flow rates or an analysis of building differential pressures
(2) If an evaluation performed under paragraph 2 or 3 of subsection (1) indicates that thecapture of the ventilation system would be reduced a registered person shall not implement or cause or permit the implementation of the proposed change to the ventilation system without a written record indicating that the highest-ranking individual at the foundry facility has reviewed the proposal and has confirmed that the proposed change meets the requirements set out in subsection 172 (2)
(3) No later than three months after a change mentioned in subsection (1) is implementedthe registered person shall ensure that the information required by subsection 51 (3) is updated and a record is made of the date on which the change was implemented
(4) A ventilation system mentioned in subsection (1) includes general exhaust ventilation alocal exhaust ventilation system and a make-up air unit but does not include a ventilation system contained wholly within an area that is isolated from foundry processes
(5) Subsection (1) does not apply if the following criteria are met1 The ventilation system is associated only with natural gas or propane combustion2 The proposed change to the ventilation system will result in a change to the
volumetric flow rate entering or exiting the enclosed area of the foundry facility inwhich the ventilation system is located that is less than the absolute valuedetermined according to the following equation
|005 (A ndash B)| where
A is the sum determined under paragraph 5 of section 52 and B is the sum determined under paragraph 6 of section 52
Multi-tenant buildings ndash SPM 55 (1) For the purposes of this section
ldquocommunity userdquo means use of part of a building for any of the following uses 1 Indoor recreational activities2 An indoor gathering of people for civic religious or social purposes
ldquonon-foundry facility tenantrdquo means a tenant that (a) is an occupant in a building that contains a foundry facility and(b) does not
(i) provide raw materials products or services to the foundry facility or
(ii) use raw materials products or services from the foundry facility(2) Subject to subsections (3) and (4) if a foundry facility is located in a building that may
have one or more non-foundry facility tenants the registered person shall (a) at least one time in every six-month period ensure that each filter of every make-up air
unit in the building that supplies air to a non-foundry facility tenant is replaced and
Ontario Ministry of the Environment and Climate Change 19
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(b) at least one time in every 12-month period ensure that the following ducts in the buildingare cleaned
(i) Ducts that supply air to a non-foundry facility tenant that is a place listed insubsection 30 (8) of O Reg 41905
(ii) Ducts that supply air to a non-foundry facility tenant that is a place used for acommunity use
(3) Clause (2) (a) does not apply with respect to a make-up air filter that is designed to becleaned if at least one time in the preceding six-month period the registered person ensures that the filter is cleaned
(4) Subsection (2) does not apply to a make-up air unit or ducts if the registered persondoes not have access to the make-up air unit or ducts and the registered person
(a) requests in writing access to the make-up air unit or ducts(b) receives either
(i) no response to the request mentioned in clause (a) or
(ii) a denial to the request mentioned in clause (a)
(c) makes a written record of the date of the request the date of the response if any and anindication of the response to the request if any and
(d) provides the person responsible for the make-up air unit with a replacement filter for themake-up air unit
(5) The registered person mentioned in subsection (2) shall ensure that the followinginformation is recorded
1 For each filter required to be replaced or cleaned under this section theidentification of the make-up air unit for which the filter was replaced or cleaned
2 The date that each filter mentioned in paragraph 1 was replaced or cleaned asapplicable
Ventilation assessment ndash optimizing capture of lead 6 (1) The ventilation coordinator shall ensure that a report entitled ldquoVentilation
Assessment Reportrdquo is prepared in accordance with this section and submitted to the Director of the Standards Development Branch of the Ministry
(2) The report required by subsection (1) shall contain the following information withrespect to each ventilation system at the foundry facility
1 The measured duct velocity of the ventilation system2 The measured static pressure of the ventilation system including where feasible
the static pressure of each branch of each local exhaust ventilation system that maycapture or convey lead and lead compounds
3 The volumetric flow rate of the ventilation system The report shall also include themethods used to determine the volumetric flow rate including any calculations
(3) Based on the information required by subsection (2) the report required by subsection(1) shall contain the following information
1 A comparison of total make-up air flow rates to the total combined flow rates ofgeneral exhaust and the local exhaust ventilation systems
2 A comparison where feasible of the measured static pressure within productionareas of the building to the measured ambient static pressure outside of the building
Ontario Ministry of the Environment and Climate Change 20
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(4) If a ventilation system may capture emissions of lead and lead compounds from afurnace operation a molten metal pouring operation or a casting cooling process the report required by subsection (1) shall in addition to the information required by subsections (2) and (3) include the following information
1 The face velocity of each hood in the ventilation system2 The results of a visual evaluation of fugitive fume capture by the ventilation system3 If the ventilation system is associated with a furnace operation the results of a visual
evaluation of fugitive fume capture by the ventilation system during melting chargingand tapping
4 The exit velocity for each exhaust stack if any in the ventilation system5 A depiction that shows the orientation and the configuration of each exhaust stack in
the ventilation system(5) Based on the information required by subsections (2) to (4) the report required by
subsection (1) shall contain an indication of (a) whether the ventilation systems at the foundry facility as a whole adequately captures
fumes of lead and lead compounds and(b) whether any part of a ventilation system is inadequate to capture fumes of lead and lead
compounds(6) If a report required by subsections (1) or (9) indicates that fumes of lead and lead
compounds are not being adequately captured the registered person shall ensure that (a) a written plan is prepared and implemented that sets out actions to be taken to
ensure that fugitive fumes of lead and lead compounds are adequately captured byventilation systems and the dates by which each action shall be taken and
(b) a written record is made of the date that each action mentioned in clause (a) isimplemented
(7) The Director mentioned in subsection (1) may deem a report submitted before July 12016 to be the report required by subsection (1) if in the opinion of the Director the information contained in the report substantially meets the information requirements set out in subsections (2) to (5)
(8) A ventilation system mentioned in this section includes general exhaust ventilation alocal exhaust ventilation system and a make-up air unit but does not include a ventilation system contained wholly within an area that is isolated from foundry processes
(9) The Director mentioned in subsection (1) may give a registered person written noticerequiring the registered person to prepare an updated version of the report mentioned in subsection (1) in accordance with the notice and to submit the updated report to the Director if the Director is of the opinion that
(a) a ventilation system or part thereof is not adequately capturing fumes of lead andlead compounds or
(b) the report was not prepared in accordance with this section(10) Before the Director gives a person a notice under subsection (9) the Director shall
give the person a draft of the notice and an opportunity to make written submissions to the Director during the period that ends 30 days after the draft is given
Notice ndash ventilation assessment report ndash optimizing capture 61 (1) The Director may give a registered person written notice requiring that a Ventilation
Assessment Report is prepared in accordance with the notice if
Ontario Ministry of the Environment and Climate Change 21
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(a) the Ministry is aware of two or more complaints related to a matter addressed in thisindustry standard having been made in respect of the foundry facility in the previous 12month period
(b) an area of the building that contains melting or pouring areas is not likely operating atnegative pressure or
(c) a static pressure measurement in respect of a local exhaust ventilation system is outsidethe range set out in Column 7 in the Operating Parameter Summary Table required bysection 11
(2) A notice given under subsection (1) shall specify each area at the foundry facility that issubject to the notice
(3) The report required by subsection (1) shall contain the following information withrespect to each registered contaminant ventilation system and area at the foundry facility that is specified in the notice
1 The measured duct velocity of the ventilation system2 The measured static pressure of the ventilation system including where feasible
the static pressure of each branch of each local exhaust ventilation system that maycapture and convey a registered contaminant
3 The volumetric flow rate of the ventilation system The report shall also include themethods used to determine the volumetric flow rate including any calculations
(4) Based on the information required by subsection (3) the report required by subsection(1) shall contain the following information
1 A comparison of total make-up air flow rates to the total combined flow rates ofgeneral exhaust ventilation and the local exhaust ventilation systems
2 A comparison where feasible of the measured static pressure within areas of thefoundry facility specified in the notice that contain foundry processes to themeasured ambient static pressure outside of the building
(5) If a ventilation system in an area of the foundry facility specified in the notice maycapture discharges of a registered contaminant in a non-negligible amount from a process set out in subsection (6) the report required by subsection (1) shall in addition to the information required by subsections (3) and (4) include the following information
1 The face velocity of each hood in the ventilation system2 The results of a visual evaluation of fugitive emissions from those processes3 If the ventilation system is associated with a furnace operation the results of a visual
evaluation of fugitive fume capture by the ventilation system during melting chargingand tapping
4 The exit velocity for each exhaust stack in the ventilation system if any5 A depiction that shows the orientation and the configuration of each exhaust stack in
the ventilation system(6) A process mentioned in subsection (5) includes the following processes
1 A metal melting process2 A furnace tapping process3 A molten metal pouring process4 A casting cooling process
(7) Based on the information mentioned in subsections (3) to (5) the report required bysubsection (1) shall contain an indication of
(a) whether the ventilation systems in each area specified in the notice adequatelycapture fugitive emissions of one or more registered contaminants and
(b) whether any part of a ventilation system in an area specified in the notice isinadequate to capture fugitive emissions of one or more registered contaminants
Ontario Ministry of the Environment and Climate Change 22
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(8) If in accordance with subsection (7) the report indicates that fugitive emissions of theregistered contaminants are not being adequately captured the registered person shall ensure that
(a) a written plan is prepared and implemented that sets out actions to be taken toensure that fugitive emissions of registered contaminants are adequately capturedby ventilation systems and the dates by which each action shall be taken and
(b) a written record is made of the date that each action mentioned in clause (a) isimplemented
(9) A ventilation system mentioned in this section includes general exhaust ventilationlocal exhaust ventilation system and a make-up air unit but does not include a ventilation system contained wholly within an area that is isolated from the foundry processes
(10) The registered person mentioned in subsection (1) shall ensure that the reportrequired by subsection (1) is submitted to the Director and to the Manager of the Standards Development Branch of the Ministry no later than the date specified in the notice
(11) Before the Director gives a person a notice under subsection (1) the Director shallgive the person a draft of the notice and an opportunity to make written submissions to the Director during the period that ends 30 days after the draft is given
Ventilation and pollution control ndash optimizing capture of lead 7 (1) If for the purposes of subsection 51 (2) a table mentioned in paragraph 1 of
subsection 51 (2) is prepared in respect of a non-ferrous metal foundry facility that uses lead the registered person shall maintain each of the following areas at a negative pressure
1 An area that contains a melt furnace that may be used to melt an alloy containinggreater than 02 per cent by weight of lead and lead compounds
2 An area that contains a pouring operation that may be used to pour an alloycontaining greater than 02per cent by weight of lead and lead compounds
(2) If for the purposes of subsection 51 (2) measurements mentioned in paragraph 2 ofsubsection 51 (2) are taken in respect of a non-ferrous metal foundry facility that uses lead the registered person shall ensure that no more than one 30-minute block average of building differential pressure in the following areas is positive in a calendar day
1 An area that contains a melt furnace that may be used to melt an alloy containinggreater than 02 per cent by weight of lead and lead compounds
2 An area that contains a pouring operation that may be used to pour an alloycontaining greater than 02 per cent by weight of lead and lead compounds
(3) If a measurement taken for the purpose of paragraph 2 of subsection 51 (2) in an areamentioned in subsection (2) is positive the registered person shall ensure that one or more operational adjustments are made as soon as practicable to return the area to negative pressure
(4) A registered person shall ensure that as soon as practicable a provincial officer isnotified in writing if an update of a table mentioned in paragraph 1 of subsection 51 (2) demonstrates that for an area mentioned in subsection (1) the value in Column 2 of the table is greater than the value in Column 4
(5) No later than 30 days after notification is required to be given under subsection (4) theregistered person shall ensure that the following information is submitted in writing to the District Manager
1 The date that the table was updated2 A copy of the updated table3 An identification of each melt furnace and pouring operation that relates to an area
mentioned in subsection (1)
Ontario Ministry of the Environment and Climate Change 23
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(6) A registered person shall ensure that as soon as practicable a provincial officer isnotified in writing of a contravention of subsection (2)
(7) If a person contravenes subsection (2) more than once in a calendar day the personmay instead of complying with subsection (6) notify a provincial officer in writing as soon as practicable after the end of the calendar day of the number of contraventions that occurred during the day
(8) No later than 30 days after notification is required to be given under subsection (6) or(7) the registered person shall ensure that the following information is submitted in writing to the District Manager
1 The date of the contravention2 The number of contraventions that occurred on the date mentioned in paragraph 1
and the time each contravention occurred3 For each contravention mentioned in paragraph 2 the measured values of the
building differential pressure4 An identification of each monitor that indicated the positive building differential
pressure5 An identification of each piece of equipment located near each monitor mentioned in
paragraph 4(9) A registered person shall not operate or cause or permit the operation of a source of
contaminant set out in subsection (10) unless the discharges from the source of contaminant are captured by a local exhaust ventilation system that is
(a) designed installed and operated in accordance with good engineering practices and(b) connected to
(i) a baghouse that has(A) a bag leak detection system that operates continuously when the
baghouse is operating(B) audio and visual alarm equipment and(C) mechanized cleaning of bags or cartridges or
(ii) a wet scrubber that has a flow monitor and audio and visual alarmequipment
(10) A source of contaminant mentioned in subsection (9) includes each source ofcontaminant that is part of one or more of the following processes
1 A metal melting process that uses lead and lead compounds2 A furnace tapping process that uses lead and lead compounds3 A molten metal pouring process that uses lead and lead compounds4 A casting cooling process that uses lead and lead compounds
(11) The registered person mentioned in subsection (9) shall ensure that each alarmrequired by that subsection is located where employees can clearly hear and see the alarm
Ventilation and pollution control ndash optimizing capture of SPM ndash new or modified facilities 8 (1) On and after July 1 2016 a registered person shall ensure that the ventilation
coordinator complies with the requirements set out in this section (2) Subject to subsection (3) no later than three months after a piece of ventilation
equipment is installed at a new foundry facility or at a foundry facility that has undergone a major modification after the later of July 1 2016 and the date the foundry facility was first registered to this industry standard the following actions shall be taken
1 Perform ventilation balancing on each local exhaust ventilation system associatedwith the piece of ventilation equipment
Ontario Ministry of the Environment and Climate Change 24
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
2 Determine whether the ventilation balancing required by paragraph 1 demonstratesthat the local exhaust ventilation system is adequate to capture and convey eachregistered contaminant associated with the ventilation system
3 Perform a visual evaluation to determine whether the local exhaust ventilationsystem is adequately capturing and conveying SPM
4 Update the record required by subsection 51 (3) to include the following informationi The results of the ventilation balancing required by paragraph 1 including
the determination required by paragraph 2ii The results of the visual evaluation required by paragraph 3iii A summary of the commissioning activities performed with respect to each
local exhaust ventilation system associated with the piece of ventilationequipment
(3) Subsection (2) only applies if the installed piece of ventilation equipment is part of alocal exhaust ventilation system that is capturing SPM emissions from a source of contaminant that is part of one or more of the following processes
1 A metal melting process2 A furnace tapping process3 A molten metal pouring process4 A casting cooling process5 A breakout or shakeout process6 A process that involves trimming grinding cutting finishing or media blasting of
castings7 A sand reclamation process
Ventilation and pollution control ndash optimizing capture of lead ndash new or modified facilities 9 (1) A registered person shall not operate or cause or permit the operation of a source of
contaminant set out in subsection (2) at a foundry facility unless the discharges from the source of contaminant are captured by a local exhaust ventilation system that is connected to at least one baghouse
(2) A source of contaminant mentioned in subsection (1) includes each source ofcontaminant at a new foundry facility or source of contaminant that was added in a major modification after February 1 2010 that is part of one or more of the following processes if the process uses an alloy containing greater than 02 per cent by weight of lead and lead compounds
1 A metal melting process2 A furnace tapping process3 A molten metal pouring process4 A casting cooling process5 A process that involves trimming grinding cutting finishing or media blasting of castings
(3) A baghouse required by subsection (1) shall have(a)automatic cleaning of bags and cartridges(b)a bag leak detection system that operates continuously when the baghouse isoperating and(c)audio and visual leak detection alarms that will alert employees to leaks
(4) The registered person mentioned in subsection (1) shall ensure that each alarmrequired by subsection (3) is located where employees can clearly hear and see the alarm
Ontario Ministry of the Environment and Climate Change 25
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Vertical and unimpeded discharges 91 (1) On and after January 1 2018 subject to subsection (2) a registered person shall
not install or cause or permit the installation of a stack at a foundry facility unless the stack is vertical and the discharges from the stack are unimpeded
(2) Subsection (1) only applies to a stack that may discharge a registered contaminant
Coke-fired cupola furnaces 10 (1) If a foundry facility has a coke-fired cupola furnace a registered person shall not
operate or cause or permit the operation of the furnace unless (a)the furnace is designed with a sufficient number of cupola afterburners to ensure thatthe combined firing rate of the cupola afterburners is at least 300000 BTU per ton ofmetal melted per hour and(b)the coke-fired cupola furnace has a local exhaust ventilation system that is connectedto a baghouse
(2) A registered person shall not operate or cause or permit the operation of a furnacementioned in subsection (1) unless each cupola afterburner required by clause (1) (a) operates continuously during the operation of the coke-fired cupola furnace
Thermal sand reclaimers ndash chlorinated or fluorinated compounds 101 (1) On and after January 1 2019 a registered person shall not operate or cause or
permit the operation of a thermal sand reclaimer that is associated with a registered contaminant set out in Appendix 2-5 at a foundry facility unless the thermal sand reclaimer is equipped with
(a) an afterburner operated at a temperature of at least 1200oC at all times when thethermal sand reclaimer is processing sand or(b)subject to subsection (2) lime scrubber and an afterburner operated at a temperatureof at least 870oC at all times when the thermal sand reclaimer is processing sand
(2) Clause (1) (b) does not apply if the thermal sand reclaimer is equipped with limescrubber and the afterburner is operated at a temperature specified in an Environmental Compliance Approval
(3) The Director appointed under section 5 of the Act for the purposes of section 203 of theAct may in an Environmental Compliance Approval specify an operating temperature of less than 870oC for an afterburner mentioned in clause (1) (b) if the Director is of the opinion that
(a)no adverse effect is likely to occur if the afterburner is operated at or above thetemperature specified by the Director or(b)each registered contaminant set out in Appendix 2 - 5 would be discharged from theafterburner in an amount that is negligible if the afterburner is operated at or above thetemperature specified by the Director
Thermal sand reclaimers ndash VOCs 102 (1) On and after January 1 2019 subject to subsection (2) a registered person shall
not operate or cause or permit the operation of a thermal sand reclaimer that is associated with a registered contaminant set out in Appendix 2-4 at a foundry facility unless the gas in the thermal sand reclaimer attains a temperature of at least 760oC for a residence time of at least 075 seconds
(2) Subsection (1) does not apply if the gas in the thermal sand reclaimer attains atemperature specified in an Environmental Compliance Approval
Ontario Ministry of the Environment and Climate Change 26
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(3) The Director appointed under section 5 of the Act for the purposes of section 203 of theAct may in an Environmental Compliance Approval specify an operating temperature of less than 760degC for a thermal sand reclaimer mentioned in subsection (1) if the Director is of the opinion that
(a)no adverse effect is likely to occur if the thermal sand reclaimer is operated at or abovethe temperature specified by the Director or(b)each registered contaminant set out in Appendix 2-4 would be discharged from thethermal sand reclaimer in an amount that is negligible if the thermal sand reclaimer isoperated at or above the temperature specified by the Director
Thermal sand reclaimers ndash SPM 103 On and after January 1 2019 a registered person shall not operate or cause or
permit the operation of a thermal sand reclaimer that is associated with a registered contaminant set out in Appendix 2-3 at a foundry facility unless the discharges from the thermal sand reclaimer are captured and conveyed to a baghouse
Thermal oxidizers ndash temperature and residence time 104 On and after January 1 2019 a registered person shall not operate or cause or
permit the operation of a thermal oxidizer at a foundry facility unless the gas in the thermal oxidizer attains a temperature of at least 760oC for a residence time of at least 075 seconds
Catalytic oxidizers ndash temperature and residence time 105 On and after January 1 2019 a registered person shall not operate or cause or
permit the operation of a catalytic oxidizer at a foundry facility unless the gas in the catalytic oxidizer attains a temperature of at least 400oC for a residence time of at least 075 seconds
Liquid spray coating process 106 (1) On and after January 1 2019 subject to subsection (2) a registered person shall
ensure that the following requirements are complied with 1 The liquid spray coatings that are used at a foundry facility shall be applied only
iwithin a spray booth andiiby use of one of the following pieces of equipment
A HVLP spray equipment that is identified by the manufacturer of the equipment ashaving a minimum transfer efficiency of 65 per cent
B Electrostatic spraying equipmentC Any other coating application equipment that is accompanied by documentation
from the manufacturer of the equipment that states the equipment has aminimum transfer efficiency of 65 per cent
2 A foundry facilitys spray booth exhaust stacks shall be vertical with no flowimpediments and shall discharge at a velocity of not less than 12 metres per second
3 A foundry facilitys spray booths shall be equipped with filters that are specified bythe manufacturer of the filters to remove at least 95 per cent of particles from thespray booth exhaust stacks emissions
(2) Subsection (1) does not apply if either of the following criteria is met
Ontario Ministry of the Environment and Climate Change 27
Technical Standards to Manage Air Pollution Version 51 ndash February 20th 2018
1 The liquid spray coating is being applied with an applicator that is not refillable2 The liquid spray coating is being applied with an applicator that is not capable of
applying the coating at a rate of greater than one litre per hour
Electric arc furnace or argon oxygen decarburizer 107 A registered person shall not operate or cause or permit the operation of the following
equipment unless the discharges from the equipment are captured by a local exhaust ventilation system that is connected to at least one baghouse
1 An electric arc furnace installed at a foundry facility on or after July 1 20192 An argon oxygen decarburizer installed at a foundry facility on or after July 1 2019
Pollution control - torch cutting metal to charge a furnace 108 On and after July 1 2017 a registered person shall not prepare or cause or permit the
preparation of material for charging a furnace in a process that involves using a torch to cut metal unless the discharges from the process are captured and conveyed to a baghouse
Pollution control ndash aluminum reverberatory furnace - scrap metal 109 A registered person shall not operate or cause or permit the operation of an aluminum
reverberatory furnace that uses as raw material scrap metal that is not generated at the foundry facility and that was installed at the foundry facility on or after July 1 2018 unless the discharges from the aluminum reverberatory furnace are where technically and economically feasible captured and conveyed to at least one baghouse
Operating Parameter Summary Table 11 (1) A registered person shall ensure that a table entitled ldquoOperating Parameter
Summary Tablerdquo is prepared in accordance with this section (2) The columns of the Operating Parameter Summary Table shall contain the following
information 1Column 1 If there is a method set out in Table 2-11 that is at a foundry facility eachpiece of equipment at the foundry facility from which the discharge of a registeredcontaminant is prevented minimized or reduced by the method2Column 2 Opposite each piece of equipment required to be set out by paragraph 1each local exhaust ventilation system and general ventilation associated with the piece ofequipment3Column 3 Opposite each piece of equipment required to be set out by paragraph 1each method set out in Table 2-11 that prevents minimizes or reduces the discharge ofa registered contaminant from the piece of equipment4Column 4 Opposite each method required to be set out by paragraph 3 each relevantoperating parameter for the method Relevant operating parameters may includetemperature and pressure differential5Column 5 Subject to subsection (6) opposite each operating parameter required to beset out in by paragraph 4 the frequency with which the operating parameter will bemeasured If an operating parameter cannot be measured the frequency with which theoperating parameter will be monitored
Ontario Ministry of the Environment and Climate Change 28
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
6Column 6 Subject to subsection (6) opposite each measurement frequency required tobe set out by paragraph 5 the location at which the operating parameter will bemeasured7Column 7 Opposite each measurement location required to be set out by paragraph 6the range of values in which the method will be considered to be operating normally8Column 8 Subject to subsection (5) opposite each normal operating range required tobe set out by paragraph 7 the range of values outside of which notification must be givento the Ministry in accordance with section 113
(3) For each piece of equipment listed in Column 1 of the Operating Parameter SummaryTable that is a furnace or that is located in a pouring area the information in Columns 1 to 3 for the piece of equipment shall be repeated in a new row of the Operating Parameter Summary Table and information for the row shall be as follows
1Column 4 Opposite each local exhaust ventilation system required to be set out inColumn 2 each relevant operating parameter for the local exhaust ventilation systemincluding static pressure in critical ducts2Column 5 Opposite each operating parameter required to be set out by paragraph 1the frequency with which the operating parameter for the local exhaust ventilation systemwill be measured3Column 6 Opposite each measurement frequency required to be set out by paragraph2 the location at which the operating parameter for the local exhaust ventilation systemwill be measured4Column 7 Opposite each measurement location required to be set out by paragraph 3the range of values in which the local exhaust ventilation system will be considered to beoperating normally
(4) A requirement in subsections (2) or (3) to set out a range of values may be satisfied bysetting out a single value or a different indicator of normal operation such as a pilot light being on or off
(5) Paragraph 8 of subsection (2) applies only to(a) an operating parameter set out in Column 3 of Items 1 to 4 of Table 2-11 at a nonshyferrous metal foundry facility that uses lead for which a registered contaminant is lead andlead compounds if the method is associated with alloys that contain greater than 02 percent by weight of lead and lead compounds and(b) an operating parameter set out in Column 3 of Items 8 to 12 of Table 2-11
(6) The Operating Parameter Summary Table required by subsection (1) does not need toinclude the following information if the date is before March 31 2017 and the information is recorded in another document
1 The measurement frequency required by paragraph 5 of subsection (2)2 The measurement location required by paragraph 6 of subsection (2)
(7) Subject to subsections (8) and (10) for each method set out in Column 3 of Table 2-11that is at a foundry facility the information set out in Columns 4 to 8 of an Operating Parameter Summary Table shall include the information set out in Columns 4 to 8 of Table 2-11
(8) If an Operating Parameter Summary Table lists a baghouse in Column 3 the Tablemay set out a range of values in Column 7 other than a range of values set out in Column 7 of Table 2-11 if the substituted range of values is consistent with a recommendation made by a professional
(9) Subject to subsection (10) if an operating range is substituted in accordance withsubsection (8) with respect to a method mentioned in clause (5) (a) the values for the notification range set opposite the operating range in Column 8 of Table 2-11 shall be substituted with the values of the substituted normal operating range
Ontario Ministry of the Environment and Climate Change 29
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(10) The information set out in Columns 4 to 8 of an Operating Parameter Summary Tablefor a baghouse that meets the criteria set out in subsection (11) may be as follows
1Column 4 Consistent with a recommendation made by a professional each operatingparameter that is considered relevant to determining the proper operation of thebaghouse2Column 5 For each operating parameter required by paragraph 1 a measurementfrequency that is consistent with a recommendation made by a professional and is no lessthan daily3Column 6 For each operating parameter required by paragraph 1 a location at whichthe operating parameter will be measured that is consistent with a recommendation madeby a professional4Column 7 For each operating parameter required by paragraph 1 the range of valuesrecommended by a professional as indicating that the air pollution control device isoperating normally5Column 8 For a method mentioned in clause (5) (a) a range of values that is no morethan 15 per cent greater range than the range required by paragraph 4
(11) The information mentioned in subsection (10) may be set for a baghouse that meetsthe following criteria
1The baghouse has a bag leak detection system that operates continuously when thebaghouse is operating2The baghouse has audio and visual leak detection alarms that will alert employees toleaks
(12) Where this section or Table 2-11 refers to an operating parameter frequencylocation or range that is to be consistent with a recommendation made by a professional the recommendation and the source of the recommendation shall be set out in the Operating Parameter Summary Table
(13) The source of a professional recommendation mentioned in subsection (12) shall beone of the following
1 An operating and maintenance manual provided by a manufacturer of the thing forwhich the recommendation is being given
2 Written instructions provided by a supplier of the thing for which the recommendationis being given
3A letter from a manufacturer mentioned in paragraph 1 or supplier mentioned inparagraph 2 setting out the recommendation4A letter from a professional engineer setting out the recommendation the rationale forthe recommendation and a description of the relevant experience with respect to therecommendation being made The engineer must have relevant experience with respectto the recommendation being made
(14) The Director may order a registered person to(a)include information in Columns 4 to 8 of the Operating Parameter Summary Table if theDirector is of the opinion that the information is necessary to ensure the normal operationof the method or local exhaust ventilation system as applicable or(b)remove information from Columns 4 to 8 of the Operating Parameter Summary Table ifthe Director is of the opinion that the information is not appropriate to ensure the normaloperation of the method or local exhaust ventilation system as applicable
(15) No later than five days after a change is made at the foundry facility that would affectthe information in the Operating Parameter Summary Table the Table shall be updated to reflect the change
(16) A reference in Column 3 of Table 2-11 to a scrubber that is new is a reference toa scrubber that is installed at the facility after the later of
Ontario Ministry of the Environment and Climate Change 30
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(a)the date on which the foundry facility is first registered with respect to this industrystandard and a contaminant set out in Appendix 2-6 and(b)July 1 2018
TABLE 2-11 Structure for Operating Parameter Summary Table
Item Column 1
Equipment
Column 2
Associated Ventilation Systems
Column 3 Associated
Method
Column 4
OperatingParameter (Method)
Column 5
MonitoringFrequency(Method)
Column 6
Monitoring
Location (Method)
Column 7
Normal Operating
Range(Method)
Column 8
Notification Range
(Method)
1 Equipment Ventilation System
Baghouse ndash Cartridge Type with Pulse Jet Cleaning
Pressure differential
Daily A location consistent with professional recommendations
2-6 inches ofwater gauge
1-8 inchesof watergauge
2 Equipment Ventilation System
Baghouse ndash Fabric Filter Mechanical Shaker Cleaned
Pressure differential
Daily A location consistent with professional recommendations
2-5 inches ofwater gauge
1-8 inchesof watergauge
3 Equipment Ventilation System
Baghouse ndash Fabric Filter Pulse Jet Cleaned
Pressure differential
Daily A location consistent with professional recommendations
4-8 inches ofwater gauge
3-10 inchesof watergauge
4 Equipment Ventilation System
Baghouse ndash Reverse-AirReverse- Jet Cleaned Type with amp without
Pressure differential Daily
A location consistent with professional recommendations
2-6 inches ofwater gauge
1-8 inchesof watergauge
Sonic Horn enhancement
5 Equipment Ventilation System
Wet Scrubber ndash Venturi Scrubber
1 Scrubbing Liquid Flowrate
2 PressureDifferential
3 pH ofscrubbing liquid ifmethod isassociatedwith aregisteredcontaminantthat is set outin Appendix 2shy7
Daily A location consistent with professional recommendations
Consistent with a recommendatio n made by a professional
NA
31Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Equipment
Column 2
Associated Ventilation Systems
Column 3 Associated
Method
Column 4
OperatingParameter (Method)
Column 5
MonitoringFrequency(Method)
Column 6
Monitoring
Location (Method)
Column 7
Normal Operating
Range(Method)
Column 8
Notification Range
(Method)
6 Equipment Ventilation System
Wet Scrubber ndash Packed Bed Scrubber
1 Scrubbing Liquid Flowrate
2 PressureDifferential
One time in every 48-hour period for an existing foundry facility
A location consistent with professional recommendations
Consistent with a recommendatio n made by a professional
NA
7 Equipment Ventilation System
Wet Scrubber ndash New Packed Bed Scrubber associated with a source of contaminant mentioned in subsection 13 (1) and a
1 Scrubbing Liquid FlowRate2 PressureDifferential 3 pH of
Continuously as required by subsection 13 (2)
A location consistent with professional recommendations
Consistent with a recommendatio n made by a professional
NA
registeredcontaminantthat is set out inAppendix 2-6
Scrubbing Liquid ifrecommended by aprofessional
8 Equipment Ventilation System
Wet Scrubber ndash Packed Bed Scrubber associated with a registered contaminant that is set out in Appendix 2-7
1 Scrubbing Liquid Flowrate
2 pH ofScrubbing Liquid
Continuously A location consistent with professional recommendations
Consistent with a recommendatio n made by a professional
The value of the operating parameter not within the range set out in Column 7
9 Equipment Ventilation System
Thermal Oxidizer Temperature Continuously
A location consistent with professional recommendations
At least 760 degC as required by section 104
Less than 760 degC
10 Equipment Ventilation System
Catalytic Oxidizer Temperature Continuously
A location consistent with professional recommendations
At least 400 degC as required by section 105
Less than 400 degC
32Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Equipment
Column 2
Associated Ventilation Systems
Column 3 Associated
Method
Column 4
OperatingParameter (Method)
Column 5
MonitoringFrequency(Method)
Column 6
Monitoring
Location (Method)
Column 7
Normal Operating
Range(Method)
Column 8
Notification Range
(Method)
11 Equipment Ventilation System
Afterburner associated with a thermal sand reclaimer at a foundry facility for which a registered contaminant is set out in Appendix 2-5
Temperature Continuously A location consistent with professional recommendations
Not less than the temperature required by section 101
Less than the applicable temperature set out in section 101
12 Equipment Ventilation System
Thermal sand reclaimer at a foundry facility for which a registered contaminant is set out in Appendix 2-4
Temperature Continuously A location consistent with professional recommendations
Not less than the temperature required by section 102
Less than the applicable temperature set out in section 102
13 Equipment Ventilation System
Lime Scrubber associated with a thermal sand reclaimer at a foundry facility for which a registered contaminant is set out in Appendix 2-5
1 Scrubbing Liquid
Flow rate
2 Anoperatingparameter thatis consistentwith arecommendati on made by aprofessional
Continuously
A location consistent with professional recommendations
Consistent with a recommendatio n made by a professional
NA
14 Equipment NA Cupola afterburner
Pilot light is on or off
Daily At the pilot light Pilot light is on Pilot light is off
33Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Equipment
Column 2
Associated Ventilation Systems
Column 3 Associated
Method
Column 4
OperatingParameter (Method)
Column 5
MonitoringFrequency(Method)
Column 6
Monitoring
Location (Method)
Column 7
Normal Operating
Range(Method)
Column 8
Notification Range
(Method)
15 Equipment Ventilation System
A method required by section 17 and any other section in this industry standard that requires a method
One or more operating parameters that are consistent with a recommendatio n made by a professional
A frequency consistent with professional recommendati ons
A location consistent with professional recommendations
Consistent with a recommendatio n made by a professional
NA
Equipment Associated Ventilation Systems
Associated Method
OperatingParameter (LEV)
MonitoringFrequency(LEV)
Monitoring
Location (LEV)
Normal OperatingRange (LEV)
NA
16
Furnaces and Pouring Lines
Local Exhaust Ventilation (LEV)
Method Static Pressure in critical ducts of the LEV
A frequency consistent with professional recommendati ons
A location consistent with professional recommendations
An operating range consistent with a recommendati on made by a professional
NA
Measurement of operating parameters 111 (1) A registered person shall ensure that measurements are taken and recorded in
accordance with this section (2) Each operating parameter set out in Column 4 of the Operating Parameter Summary
Table required by section 11 shall be measured with the frequency set out in Column 5 of the Table at the location set out in Column 6 of the Table
(3) If an Operating Parameter Summary Table sets out an operating parameter for abaghouse which is required to be measured on a daily basis the measurement taken and recorded for the purposes of this section shall be taken when the baghouse is not in a bag cleaning cycle
(4) Subject to subsection (5) the following information shall be recorded1Each measurement required to be taken under subsection (1)2The date on which each measurement mentioned in paragraph 1 was taken
(5) Subsection (4) does not apply to equipment set out in an Operating ParameterSummary Table for the purpose of Item 15 of Table 2-11 or with respect to a baghouse if the bag house has
(a)a bag leak detection system that operates continuously when the baghouse isoperating and
34Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(b)audio and visual leak detection alarms that will alter employees to leaks
Deviations from operating parameters 112 (1) Subject to subsection (4) for each method and local exhaust ventilation system
set out in the Operating Parameter Summary Table required by section 11 a registered person shall ensure the following steps are taken
1 Determine if the measured value for each operating parameter set out opposite themethod or ventilation system deviates from the normal operating range of values setout in Column 7 opposite the operating parameter
2 Subject to subsection (3) if it is determined under paragraph 1 that a value deviatedfrom the normal operating range make one or more operational adjustments assoon as practicable so that the value of the operating parameter is within the normaloperating range
(2) If an operational adjustment is required to be made under paragraph 2 of subsection(1) the registered person shall ensure that the following information is recorded
1 The operating parameter for which the value was measured2 The method or local exhaust ventilation system to which the operating parameter
mentioned in paragraph 1 relates3 The normal operating range for the parameter mentioned in paragraph 14 The measured value of the operating parameter mentioned in paragraph 1 taken
during the duration of the deviation5 The date time and duration of the deviation6 An explanation of the suspected cause of the deviation7 A description of each operational adjustment required to be made under paragraph 2
of subsection (1) and the date each operational adjustment was completed8 The position title of personnel who assigned a person to make each operational
adjustments(3) Paragraph 2 of subsection (1) does not apply with respect to a value for a baghouse
operating parameter that was recorded during a bag cleaning cycle (4) Subsection (1) does not apply with respect to a method set out in items 9 to 12 of
Table 2-11 if the date is before January 1 2019
Notification of deviations from operating parameters 113 (1) Subject to subsections (2) to (4) if in accordance with section 11 a notification
range is required to be set out in Column 8 of an Operating Parameter Summary Table a registered person shall ensure that as soon as practicable a provincial officer is notified in writing if the value of an operating parameter deviates from the notification range
(2) Subsection (1) does not apply with respect to an operating parameter set out for abaghouse if
(a) the value for the operating parameter was measured during a bag cleaning cycle or(b) a new filter was installed in the baghouse less than 31 days before the deviation
occurred(3) If a person is required to notify under subsection (1) more than one time in a 24-hour
period the person may instead of complying with subsection (1) notify a provincial officer in writing as soon as practicable after the end of the 24-hour period of the number of deviations that occurred during the period
(4) Subsection (1) does not apply with respect to an operating parameter set out in items 9to 12 of Table 2-11 if the date is before January 1 2019
Ontario Ministry of the Environment and Climate Change 35
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Phase-in for new air pollution control devices 114 Sections 11 to 113 do not apply in respect of an air pollution control device or local
exhaust ventilation system at a foundry facility for a period of six months after the installation of the device or system if the device or system is installed after the date on which the foundry facility is first registered with respect to this industry standard
Inspection and maintenance summary table 115 (1) A registered person shall ensure that a table entitled ldquoInspection and Maintenance
Summary Tablerdquo is prepared in accordance with this section (2) The columns of the Inspection and Maintenance Summary Table shall contain the
following information 1 The first column shall contain
ieach air pollution control device at the foundry facility that is associated with aregistered contaminantiieach local exhaust ventilation system associated with a furnace or pouringoperation andiiieach monitoring device at the foundry facility used to take a measurement that isrequired by this industry standard including pressure gauges flow meters pHmeters and building differential pressure monitors
2 Opposite each thing required to be set out by paragraph 1 the frequency with whicheach thing is to be inspected to ensure its proper operation
3 Opposite each inspection frequency required to be set out by paragraph 2 themaintenance objectives to be verified by the inspection
(3) Subject to subsection (4) for each thing identified in Column 1 of Table 2-115 theinformation set out in the Inspection and Maintenance Summary Table opposite the item shall include the information set out in Columns 2 to 3 of Table 2-115
(4) An Inspection and Maintenance Summary Table may set out a frequency other than afrequency set out in Column 2 of Table 2-115 if the substituted frequency is based on a recommendation made by a professional
(5) Where this section or Table 2-115 refers to a thing that is to be consistent with arecommendation made by a professional the recommendation and the source of the recommendation shall be set out in the Inspection and Maintenance Summary Table
(6) The source of a recommendation mentioned in subsection (5) shall be one of thefollowing documents
1 An inspection frequency set out in an operating and maintenance manual providedby a manufacturer of the thing for which the recommendation is being given
2 An inspection frequency set out in written instructions provided by a supplier of thething for which the recommendation is being given
3 A letter from a manufacturer mentioned in paragraph 1 or a supplier mentioned inparagraph 2 that has relevant experience with foundry processes and equipmentsetting out the recommended inspection frequency
4 A letter from a professional engineer setting out the recommended inspectionfrequency the rationale for the recommendation and a description of the relevantexperience with respect to the recommendation being made The engineer musthave relevant experience with respect to the recommendation being made
(7) The Director may order a registered person to(a) include information in Columns 1 to 3 of the Inspection and Maintenance Summary
Table if the Director is of the opinion that the information is necessary to ensure thenormal operation of the air pollution control device ventilation system or monitoringdevice as applicable or
Ontario Ministry of the Environment and Climate Change 36
olumn 1
ir Pollution Control evice Monitoring evice Local Exhaust entilation System
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 (b) remove information from Columns 1 to 3 of the Inspection and Maintenance
Summary Table if the Director is of the opinion that the information is notappropriate to ensure the normal operation of the air pollution control deviceventilation system or monitoring device as applicable
(8) No later than five days after a change is made at the foundry facility that would affectthe information in the Inspection and Maintenance Summary Table the Table shall be updated to reflect the change
TABLE 2- 115 Structure for Inspection and Maintenance Summary Table
Item
Column 1
Air Pollution Control Device Monitoring Device Local Exhaust Ventilation System
Column 2
Inspection Frequency
Column 3
Maintenance Objective
1 Baghouse (fabric filter or cartridge)
Monthly
i Bag leak detection system required by sub-subclause 7(9) (b) (i) (A) is working
ii If baghouse has a dust hopper alarm alarm is workingproperly
iii If baghouse does not have a dust hopper alarm dusthopper is not likely to overflow
iv No visual evidence of holes or evidence of wear in ductshoods expansion joints or flex connections of fumecapture equipment
v No visual evidence of flow constructions caused by dentsin ducts or misaligned expansion joints and flexconnections of fume capture equipment
vi No visual evidence of fan housing erosionvii Dampers are at the proper settings
2 Baghouse (fabric filter or cartridge)
At least one time in every six-month period
i No visual evidence damaged bags cleaning mechanism components dampers and spare parts are available ifneeded
ii No loose or worn belts in the fan or bloweriii Impellers in the fanblower are properly balancediv No wear erosion or dust accumulation on an impeller in
the fan or blower v No erosion of airlock or conveyor system housings in the
dust removal conveyor systemvi No unusual vibration or squealing with respect to the
fanblower dust removal system (including airlocks andscrew conveyor)
vii All bearings in the fan and blower and dust removalsystem are adequately lubricated
3 Baghouse (fabric filter or cartridge)
Yearly
i No signs of corrosion on any weld joint or sealii No sign of excessive wear on baffle plates and tubesheetiii All fasteners tightly in placeiv All welds joints and seals are clean and painted to avoid
rusting v Ducts are free of accumulation of dust
4 Wet Scrubber Weekly
i Each chemical metering pump is operating properlyii The system is not leakingiii Each damper system is operating properlyiv Fan and fan bearings are free of leaks cracks and loose
fittingsv No pump or fan motor is making unusual vibration heat or
noise
37Ontario Ministry of the Environment and Climate Change
Column 1
Air Pollution Control Device Monitoring Device Local Exhaust Ventilation System
Item Column 2
Inspection Frequency
Column 3
Maintenance Objective
5 Wet Scrubber Monthly
i No spray nozzle or bar is clogged or worn as indicated byits distribution pattern
ii No flow strainer or fan housing drain is cloggediii The fan bearings belts and seals are in good conditioniv The fan impeller and blades are free of solids build-up and
erosionv Pressure gauges are accurate
6 Wet Scrubber At least one time in every three-month period
i No excessive wear corrosion or build-up on the mainbody
ii Piping is not eroding or clogged
7 Wet Scrubber At least one time in every six-month period
i Sump and ductwork are free of solids build-upii No internal breakages or excessive corrosioniii Ductwork fan and structural supports are free of
deterioration and damageiv Flow meter is accurate (verify) v Calibrate instrumentation where feasible
8 Local Exhaust Ventilation System
At least one time every calendar month
i Slide gates are correctly positionedii Dampers that are not secured in place on critical ducts for
furnace and pouring operations are correctly positioned
9 Local Exhaust Ventilation System Yearly i Dampers that are secured in place on critical ducts for
furnace and pouring operations are correctly positioned
10 Cupola Afterburner
A frequency consistent with a professional recommendation
i Cupola afterburner maintained consistent withmanufacturerrsquos recommendation
11 Oxidizer (Thermal or Catalytic) Monthly
i Fan bearings and belts are free of excessive wear anddamage
ii Fan motor oil level is acceptableiii Dampers for regenerative thermal oxidizers are
operating properly
12 Oxidizer (Thermal or Catalytic)
At least one time in every three-month period
i Ductwork is free of leaks ii Fan motor bearings are lubricatediii Burner is free of corrosion and warpingiv Burner jets are free of corrosion and depositsv Electrical valves and interlock switches are free of
moisture leaks contacts are clean and insulation is notdeteriorating
vi Interlocks are working properly
13 Oxidizer (Thermal or Catalytic)
At least one time in every six-month period
i Outer shell is free of weld cracks and hot spotsii Ductwork is free of blockages and excessive dirt
14 Monitoring Device Yearly i Monitoring device is measuring accurately
Column 1
Air Pollution Control Device Monitoring Device Local Exhaust Ventilation System
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Inspection and maintenance activities 116 (1) A registered person shall ensure that each thing set out in Column 1 of the
Inspection and Maintenance Summary Table required by section 115 is inspected with the frequency set out in Column 2 of the Table to verify whether the maintenance objectives set out in Column 3 are met
(2) A registered person shall ensure that the following information is recorded
38Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
1 The date of each inspection performed for the purpose of subsection (1)2 Based on the date in paragraph 1 and the date of the previous inspection performed
for the purpose of subsection (1) an indication of whether the inspection wasperformed with the required frequency
3 An indication of which maintenance objectives were not met4 The position title of personnel who assigned a person to perform the inspection
mentioned in paragraph 1
Deviations - inspection and maintenance 117 (1) No later than the last day of each month a registered person shall ensure that
the records required by section 116 are reviewed to determine if (a) each inspection required by section 116 was performed with the frequency set out
opposite the activity during the month and(b) an inspection revealed that any maintenance objectives were not met
(2) If it is determined under clause (1) (a) that an inspection was not performed with therequired frequency the registered person shall ensure that the following information is recorded
1 A description of the inspection that was to be performed2 The date on which the inspection was to be performed3 The reason the inspection was not performed with the required frequency4 A description of actions to be taken to ensure the inspection will be performed with
the required frequency5 The position title of personnel who assigned a person to take the actions mentioned
in paragraph 4(3) If it is determined under clause (1) (b) that a maintenance objective was not met the
registered person shall ensure that one or more actions are taken as soon as practicable to meet the maintenance objective
(4) If an action is required to be taken under subsection (3) the registered person shallensure that the following information is recorded
1 A description of the maintenance objective that was not met2 The reason the maintenance objective was not met3 A description of each action to be taken to ensure that the maintenance objective is
met4 The date on which each action was taken5 The position title of personnel who assigned a person to take each action
Recurring malfunctions 118 (1) Subject to subsection (3) if an air pollution control device or a local exhaust
ventilation system at a foundry facility malfunctions in the same way more than one time in any six-month period the registered person shall ensure that the highest-ranking individual at the foundry facility is notified in writing of the malfunction no later than five days after the second malfunction
(2) If notification is required to be made under subsection (1) the registered person shallensure that the ventilation coordinator as soon as practicable after the date of the second malfunction prepares and implements a plan to address and prevent a recurrence of the malfunction
(3) Subsection (1) applies only to(a) an air pollution control device that may discharge a registered contaminant and
Ontario Ministry of the Environment and Climate Change 39
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(b) a local exhaust ventilation system that may capture or convey a registeredcontaminant
Operational practices ndash minimization of VOCs 12 (1) The registered person shall ensure that a written procedure is developed and
implemented in accordance with good engineering practice to minimize the discharge of and odour associated with registered contaminants listed in Appendix 2-4 from each source of contaminant that is part of one or more of the following processes
1 A mold production process (hot box and warm box)2 A core production process (shell core)3 A core production process (cold box using amine catalyst)4 A casting cooling process5 A breakout or shakeout process6 A liquid spray coating process
(2) Subject to subsection (5) the Director may give a written notice to a registered personrequiring the registered person to ensure that
(a) an analysis of the methods set out in subsection (3) and combinations of thosemethods is performed to determine which are technically and economically feasiblewith respect to the sources of odour emissions listed in the written notice
(b) a record is made of the methods and combinations of methods that are determinedunder clause (a) to be technically and economically feasible
(c) a plan to implement one or more of the technically and economically feasible optionsmentioned in clause (b) is submitted to the Director and
(d) no later than 24 months after receiving written notification that the Director issatisfied with the plan mentioned in clause (c) the plan is implemented inaccordance with good engineering practices
(3) The analysis of technically and economically feasible options to address odour impactsrequired by clause (2) (a) shall consider only the following material substitutions process changes and air pollution control technologies
1 Cold setting resins2 Subject to subsection (4) non-aromatic solvents that do not contain chemicals with a
ring of carbon atom such as benzene and naphthalene3 Naphthalene depleted solvent resin4 Vacuum forming5 Thermal oxidizer6 Catalytic oxidizer
61 Mold Gas Vent Light-off 7 Adsorption system8 Wet scrubbers
81 HVLP spray equipment 82 Low VOC coatings
9 Another material substitution process change or air pollution control technology thatin the opinion of the Director is equivalent to a technology listed in paragraphs 1 to82
(4) The use of a non-aromatic solvent as a material substitution option to address odourimpacts applies only in respect of an amine-hardened urethane-bonded cold-box core preparation process
(5) The Director may give a notice under subsection (2) only if the Director is aware ofcomplaints with respect to odour related to the foundry facility and is of the opinion that the
Ontario Ministry of the Environment and Climate Change 40
Technical Standards to Manage Air Pollution Version 51 ndash February 20th 2018
cause of the complaint may be due to the discharge of a registered contaminant listed in Appendix 2-4 into the air from a source of contaminant that is part of a process described in subsection (1)
(6) Before the Director gives a person a notice under subsection (2) the Director shall givethe person a draft of the notice and an opportunity to make written submissions to the Director during the period that ends 30 days after the draft is given
Pollution control ndash minimization of total amines 13 (1) A registered person shall not operate or cause or permit the operation of a source
of contaminant at a foundry facility that is part of a core production process (cold box using amine catalyst) unless the discharges from the source of contaminant are captured by a local exhaust ventilation system that where technically and economically feasible is connected to a wet scrubber
(2) Each operating parameter set out in the Operating Parameter Summary Table requiredby section 11 in respect of a wet scrubber referred to in subsection (1) shall be monitored continuously if the wet scrubber is
(a) a packed bed scrubber and(b) installed on or after the later of
(i) the date on which the foundry facility is first registered with respect to thisindustry standard and a contaminant set out in Appendix 2-6 and
(ii) July 1 2018
Operational practices ndash minimization of sulphur dioxide 14 A registered person shall ensure that a written procedure is developed and
implemented in accordance with good engineering practices to minimize the discharge of sulphur dioxide from a source of contaminant present at the foundry facility that is part of a core production process (cold box using sulphur dioxide catalyst) The procedure shall include steps to minimize the discharge of sulphur dioxide during during start up shut down and malfunction of the source of contaminant
Pollution control ndash minimization of sulphur dioxide 15 A registered person shall not operate or cause or permit the operation of a source of
contaminant that is part of a core production process (cold box using sulphur dioxide catalyst) unless the discharges from the source of contaminant are captured by a local exhaust ventilation system that where technically and economically feasible is connected to a wet scrubber
Complaint procedure 16 (1) A registered person shall ensure that the following steps are taken to properly
respond to each complaint that relates to the discharge of a contaminant into the air from a foundry facility
1A prompt response is made to the person who made the complaint unless the personrequests that a response not be made or fails to provide contact information2Action is taken to remedy the cause of the complaint3A written record of the complaint is prepared that includes the following information
Ontario Ministry of the Environment and Climate Change 41
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
i A description of the complaintii The date and time that the complaint was receivediii The date time and suspected cause of the incident to which the complaint
relates including whether any outdoor activities may have given rise to thecomplaint
iv Ambient temperature at the time of the incident to which the complaintrelates
v The approximate wind direction and wind speed at the time of the incidentto which the complaint relates
vi The general weather conditions at the time of the incident to which thecomplaint relates
vii A description of any actions taken to address the incident to which thecomplaint relates and the date each action was completed
viii A description of any actions taken to prevent a future incident similar to theincident to which the complaint relates and the date each action wascompleted
(2) If a complaint is made that relates to a matter addressed in this industry standard theregistered person shall ensure that the Ministryrsquos Spills Action Centre is notified of the complaint as soon as practicable after the complaint is made
(3) No later than five days after notification is required to be given under subsection (2) theregistered person shall ensure that the following information is submitted in writing to a provincial officer
1 A description of the complaint2 The time and date of the incident to which the complaint relates3 A description of any actions taken or that will be taken to address the incident to
which the complaint relates4 The dates on which each action mentioned in paragraph 3 was completed or is
anticipated to be completed
Identifying managed sources 17 (1) A registered person shall ensure that a table is prepared in accordance with this
section and updated in accordance with section 172 (2) The table required by subsection (1) shall contain the following information
1 Column 1 Each piece of equipment at the foundry facility from which the dischargeof a registered contaminant is prevented minimized or reduced by a methodmentioned in subsection (3)
2 Column 2 Opposite each piece of equipment required to be set out by paragraph 1each local exhaust ventilation system and general ventilation associated with thepiece of equipment
3 Column 3 Opposite each piece of equipment required to be set out by paragraph 1each method that prevents minimizes or reduces the discharge of a registeredcontaminant from the piece of equipment
(3) A method mentioned in paragraph 3 of subsection (2) includes a method such as(a)the use of an air pollution control device(b)the selection and use of equipment that more effectively prevents minimizes orreduces the discharge of a registered contaminant than the selection or use of otherequipment
Ontario Ministry of the Environment and Climate Change 42
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(c)the operation of a process or piece of equipment in a manner that prevents minimizesor reduces the discharge of a registered contaminant into the air from the process or pieceof equipment(d)the design installation and operation of a stack in a manner that increases thedispersion of contaminants and(e)the use of an additive to prevent minimize or reduce the discharge of a registeredcontaminant
(4) If a method mentioned in paragraph 3 of subsection (2) is the selection of equipment inaccordance with clause (3) (b) the equipment shall be listed as the method Column 3 of the table and as the equipment in Column 1 of the table
(5) If a new foundry facility is not constructed at the time of registration the equipmentventilation systems and methods required to be listed in the table required by subsection (1) shall until the construction is complete be the proposed equipment ventilation systems and methods
Requirement to continue the management of sources 171 A registered person shall not operate or cause or permit the operation of a piece of
equipment set out in the table required by section 17 unless (a)the discharge of registered contaminants from the piece of equipment is preventedminimized or reduced by a method that is at least as effective at preventing minimizing orreducing the discharge into the air as the associated method required to be listed oppositethe piece of equipment in Column 3 of the table and(b)the discharge of registered contaminants from the piece of equipment is captured by aventilation system that is at least as effective at capturing the discharge as the associatedventilation system required to be listed opposite the piece of equipment in Column 2 of thetable
Changes to managed sources 172 (1) No later than 30 days after any of the following changes occur at a foundry facility
the table required by section 17 shall having regard to subsection (2) be updated in accordance with the following rules
1If a method to prevent minimize or reduce the discharge of a registered contaminant isadded or replaced at the foundry facility the table shall be updated to reflect the change2If a ventilation system that captures a registered contaminant is added or replaced at thefoundry facility the table shall be updated to reflect the change3If a piece of equipment that may discharge or from which may be discharged aregistered contaminant is added or replaced at the foundry facility the table shall beupdated to reflect the change4If a piece of equipment set out in the table is removed from the foundry facility thepiece of equipment shall be removed from the table5If all equipment associated with a method set out in the table has been removed fromthe table the method shall be removed from the table6If all equipment associated with a ventilation system set out in the table have beenremoved from the table the ventilation system shall be removed from the table7If a notice given under subsection (4) indicates that a method is no longer necessarythe method shall be removed from the table8If a notice given under subsection (4) indicates that a ventilation system is no longernecessary the ventilation system shall be removed from the table
Ontario Ministry of the Environment and Climate Change 43
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
9If the table is updated in accordance with paragraphs 7 and 8 such that no method orventilation system is set out opposite a piece of equipment in the table the piece ofequipment shall be removed from the table
(2) Subject to subsections (3) and (4) a change mentioned in subsection (1) shall not bemade unless the following criteria are met
1A change that adds replaces or otherwise alters a method shall add replace or alter themethod in a manner that is at least as effective at preventing reducing or minimizing thedischarge of registered contaminants as the method that was listed in the tableimmediately prior the change2A change that adds replaces or otherwise alters a ventilation system shall add replaceor alter the ventilation system in a manner that is at least as effective at capturingregistered contaminants as the ventilation system that was listed in the table immediatelyprior the change3A change that adds a piece of equipment that is similar to a piece of equipment requiredto be set out in the table shall only be made if
i Column 2 of the table contains a ventilation system that is at least aseffective at capturing contaminants as the most effective ventilation systemassociated with a similar piece of equipment and
ii Column 3 of the table contains a method that is at least as effective atpreventing minimizing or reducing the discharge of registered contaminantsas the most effective method associated with a similar piece of equipment
(3) Subsection (2) does not apply if the change is required by a section of this industrystandard other than this section
(4) The Director may upon request give a registered person written notice indicating that achange that does not meet the requirements mentioned in subsection (2) may be made in accordance with the notice if the Director is of the opinion that at least one of the following statements is true
1The method or system that is the subject of the request is comparable to theeffectiveness of the method or system that would be required by subsection (2)2Any adverse effect would likely not be better prevented eliminated or ameliorated if amethod or system required by subsection (2) were used3No adverse effect is likely to occur4The registered contaminants affected by the change are discharged in an amount that isnegligible
(5) A request mentioned in subsection (4) shall be made by a registered person and shallinclude the following information
1A rationale for the request2Each piece of equipment associated with the method or system that is the subject of therequest
(6) Before the Director gives a person a notice under subsection (4) the Director shall givethe person a draft of the notice and an opportunity to make written submissions to the Director during the period that ends 30 days after the draft is given
Specified management of sources 173 The Director may order a registered person to use a method or ventilation system if
(a)a change was made to a method or ventilation system that in the opinion of theDirector does not meet the criteria set out in subsection 172 (2) or
Ontario Ministry of the Environment and Climate Change 44
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(b)a piece of equipment is or was previously listed in the table required by section 17 andthe Director is of the opinion that discharges from the piece of equipment may cause anadverse effect
Notification of changes to management of sources 174 (1) Subject to subsection (2) no later than 30 days after a change mentioned in
section 172 or 173 is made at a foundry facility the registered person shall ensure that a provincial officer is notified in writing of the change
(2) Subsection (1) does not apply if the thing affected by the change is a thing which maydischarge or from which may be discharged a registered contaminant in an amount that is negligible
(3) The notification required by subsection (1) shall include the following information1 A description of the change including a description of the equipment methods and
ventilation systems affected by the change and the date the change was made2 One of the following with respect to the change mentioned in paragraph 1
i An explanation of how the change meets the criteria set out in subsection172 (2)
ii If the change was authorized by a notice given under subsection 172 (4)the reference number of the notice
iii If the change was required by an order given under section 173 thereference number of the order
Summary reports 18 (1) A registered person shall ensure that annual summaries are prepared and
reviewed in accordance with this section (2) No later than March 31 each year the following summaries shall be prepared and the
information therein shall pertain to the preceding calendar year 1 A table labelled ldquoImplementation Summary Tablerdquo that for the calendar year sets
outi a summary of the provisions of this industry standard that apply to the
foundry facility in accordance with section 2 andii for each provision mentioned in subparagraph i
A an indication of the date on which the provision applies to the foundry facilityand
B if compliance with the provision has been achieved an indication of the date onwhich compliance was achieved
2 A summary that for the calendar yeari sets out changes made to ventilation systems at the foundry facilityii summarizes the information that was required to be updated in accordance
with subsection 54 (3) andiii summarizes the information required by subsection 54 (2) to be recorded
3 If during a calendar year an action is required to be taken in accordance withclause 6 (6) (a)
i a description of each action taken during the year to ensure fugitiveemissions of lead and lead compounds are adequately captured
ii a summary of the information that was required to be recorded inaccordance with clause 6 (6) (b)
Ontario Ministry of the Environment and Climate Change 45
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
iii a summary of all actions taken to date and actions still to be taken andiv any information that was required to be updated by subsection 6 (9)
4 If during a calendar year an action is required to be taken in accordance withsubsection 61 (8)
i a description of each action taken during the year to ensure fugitiveemissions of registered contaminants are adequately captured
ii a summary of the information that was required to be recorded inaccordance with subsections 61 (8) and
iii a summary of all actions taken to date and actions still to be taken5 A summary that for the calendar year sets out changes made to the Operating
Parameter Summary Table and summarizes the information that was required to beupdated in accordance with subsection 11 (15)
6 A record labelled ldquoSummary of Deviationsrdquo that for the calendar year sets outi a summary of the information required by paragraph 6 of subsection 51 (3)
and subsections 112 (2) 117 (2) and 117 (4)ii an indication of any changes in the number of deviations from the summary
of the previous yeariii the number of times an event that caused one or more deviations occurred
at the facility during the calendar yeariv an indication of whether any of the events mentioned in subparagraph iii
were of particular concernv an assessment of whether the number of events mentioned in
subparagraph iii indicate a recurring issue both in respect of the calendaryear and in respect of previous calendar years and
vi an explanation of any actions taken to address the events mentioned insubparagraph iii
7 A table labelled ldquoPerformance Summary Tablerdquo that for the calendar year sets outi a summary of all notices required to be given under subsections 7 (6) or (7)
and all notices required to be given under subsection 113 (1) that relate amethod set out in Column 3 of Items 9-12 and 14 of Table 2-11
ii an indication of whether a notice has been given to the foundry facility undersubsections 6 (9) 61 (1) 12 (2) 172 (4) and
iii an indication of whether an order has been given to the foundry facilityunder subsections 11 (14) or 115 (7) or section 173
8 A summary that for the calendar year sets outi the number of notifications given under subsection 118 (1)ii for each notification mentioned in subparagraph i a summary of the plan
that was required to be prepared by subsection 118 (2) andiii for each plan mentioned in subparagraph ii a summary of the actions taken
and the dates by which remaining actions are anticipated to be taken9 A summary that for the calendar year sets out changes made to the Inspection and
Maintenance Summary Table and summarizes the information that was required tobe updated in accordance with subsection 115 (8)
10 A table labelled ldquoAnnual Summary of Changes to Source Informationrdquo that for thecalendar year sets out the following information
i Column 1 Each piece of equipment required to be set out in Column 1 ofthe Table required by subsection 17 (1)
ii Column 2 Opposite each piece of equipment required to be set out byparagraph 1 each local exhaust ventilation system and general ventilationassociated with the piece of equipment
Ontario Ministry of the Environment and Climate Change 46
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
iii Column 3 Opposite each piece of equipment required to be set out byparagraph 1 each method that prevents minimizes or reduces thedischarge of a registered contaminant from the piece of equipment
iii Column 4 Opposite each piece of equipment required to be set out byparagraph 1 an indication whether the information in Columns 1 2 or 3 haschanged from information set out in the previous calendar year
11 A table labelled ldquoComplaint Summary Tablerdquo that sets out the total number ofcomplaints described in subsection 16 (2) that have been received by the foundryfacility in the calendar year and compares the number to the number of complaintsreceived by the foundry facility in the previous calendar year
(3) No later than March 31 each year the highest-ranking individual at the foundry facilityshall certify in writing that the summaries required by paragraphs 1to 8 and 11 of subsection (2) have been prepared in accordance with this industry standard and that the information contained in the summaries is
(a)accurate and complete and(b)true to the best of his or her knowledge
(4) The summary tables required by paragraphs 1 and 7 of subsection (2) shall be(a) made available for examination by any person without charge by ensuring it is
posted and available on the website for the foundry facility or by making it availableduring regular business hours at the place to which the report relates and
(b) given without charge to any person within 15 days after the person requests it
Records 19 (1) A registered person shall ensure that each record required in accordance with
section 2 of this industry standard is retained at the foundry facility for at least five years and made available to a provincial officer or Director upon request as soon as practicable
(2) A person required to make a record available under subsection (1) shall make itavailable in a form approved by the Director including if required by the Director an electronic format specified by the Director
(3) In addition to the records mentioned in subsection (1) a registered person shall ensurethat each document relating to the recommendations of the manufacturer for each device at the foundry facility with respect to the use operation and maintenance of the device is retained for the period during which the device is used or operated
Ontario Ministry of the Environment and Climate Change 47
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Appendix 2-1 All Contaminants
Number CAS Number Contaminant Name
1 95-93-2 1245-Tetramethylbenzene
2 33329-35-0 13-Propanediamine NN-Bis[3shy(Dimethylamino)Propyl]-NN-Dimethylshy
3 616-47-7 1-Methylimidazole
4 90-12-0 1-Methylnaphthalene
5 1120-36-1 1-Tetradecene
6 90-72-2 246-Tris(Dimethylaminomethyl)Phenol
7 91-57-6 2-Methylnaphthalene
8 617-94-7 2-Phenylisopropanol
9 996-35-0 2-Propanamine NN-Dimethylshy
10 110-26-9 2-Propenamide NN-Methylenebisshy
11 68540-66-9 2-Propenoic Acid Polymer With Ethyl 2-PropenoateAnd Isooctyl 2-Propenoate
12 208-96-8 Acenaphthylene - As B[A]P
13 75-07-0 Acetaldehyde
14 64-19-7 Acetic Acid
15 67-64-1 Acetone
16 98-86-2 Acetophenone
17 260-94-6 Acridine
18 107-02-8 Acrolein
19 79-10-7 Acrylic Acid
20 68551-13-3 Alcohols C12-15 Ethoxylated Propoxylated
21 7429-90-5 Aluminum [And Other Compounds]
22 1344-28-1 Aluminum Oxide
23 637-12-7 Aluminum Tristearate
48Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
24 7664-41-7 Ammonia
25 62-53-3 Aniline
26 120-12-7 Anthracene - As B[A]P
27 191-26-4 Anthranthrene - As B[A]P
28 7440-36-0 Antimony [And Other Compounds]
29 7440-37-1 Argon
30 70693-06-0 Aromatic Hydrocarbons C9-11
31 64742-95-6 Aromatic Naphtha Type I
32 7440-38-2 Arsenic And Compounds
33 7440-39-3 Barium [And Other Compounds]
34 10361-37-2 Barium Chloride (BaCl2)
35 1302-78-9 Bentonite
36 71-43-2 Benzene
37 26447-40-5 Benzene 11-Methylenebis(Isocyanatoshy
38 527-53-7 Benzene 1235-Tetramethylshy
39 141-93-5 Benzene 13-Diethylshy
40 105-05-5 Benzene 14-Diethylshy
41 5873-54-1 Benzene 1-Isocyanato-2-[(4shyIsocyanatophenyl)Methyl]shy
42 104-15-4 Benzenesulfonic Acid 4-Methylshy
43 25321-41-9 Benzenesulfonic Acid Dimethylshy
44 56-55-3 Benzo(A)Anthracene - As B[A]P
45 203-33-8 Benzo(A)Fluoranthene - As B[A]P
46 50-32-8 Benzo(A)Pyrene
47 205-99-2 207-08-9 Benzo(B)+(K)Fluoranthene ndash As B[A]P
48 205-99-2 Benzo(B)Fluoranthene ndash As B[A]P
49Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
49 192-97-2 Benzo(E)Pyrene - As B[A]P
50 191-24-2 Benzo(GHI)Perylene - As B[A]P
51 207-08-9 Benzo(K)Fluoranthene ndash As B[A]P
52 69-72-7 Benzoic Acid 2-Hydroxyshy
53 7440-41-7 Beryllium And Compounds
54 7440-69-9 Bismuth [And Other Compounds]
55 14075-53-7 Borate(1-) Tetrafluoro- Potassium
56 1303-96-4 Borax
57 10043-35-3 Boric Acid
58 7440-42-8 Boron
59 7726-95-6 Bromine
60 106-97-8 Butane
61 123-86-4 Butyl Acetate Nshy
62 1328-53-6 CI Pigment Green 7
63 7440-43-9 Cadmium And Cadmium Compounds
64 7440-70-2 Calcium [And Other Compounds]
65 75-20-7 Calcium Carbide
66 471-34-1 Calcium Carbonate
67 10043-52-4 Calcium Chloride Anhydrous
68 592-01-8 Calcium Cyanide (As Total Salt)
69 7789-75-5 Calcium Fluoride (CaF2)
70 1305-62-0 Calcium Hydroxide
71 1305-78-8 Calcium Oxide
72 1592-23-0 Calcium Stearate
73 86-74-8 Carbazole
50Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
74 7440-44-0 Carbon
75 1333-86-4 Carbon Black
76 630-08-0 Carbon Monoxide
77 7782-50-5 Chlorine
78 7440-47-3 Chromium And Chromium Compounds (Metallic Divalent And Trivalent)
79 7440-47-3 Chromium Compounds (Hexavalent)
80 218-01-9 Chrysene - As B[A]P
81 - Coal Dust (Anthracite Bituminous Lignite amp Seacoal)
82 7440-48-4 Cobalt [And Other Compounds]
83 65996-77-2 Coke (Coal)
84 7440-50-8 Copper [And Other Compounds]
85 1319-77-3 Cresols
86 80-15-9 Cumene Hydroperoxide
87 41556-26-7 Decanedioic Acid Bis(12266-Pentamethyl-4shyPiperidinyl) Ester
88 103-23-1 Di-(2-Ethylhexyl) Adipate
89 53-70-3 Dibenz(AH)Anthracene ndash As B[A]P
90 53-70-3 215-58-7 Dibenzo(AH)+(AC) Anthracene - As B[A]P
91 132-64-9 Dibenzofuran
92 84-74-2 Dibutyl Phthalate (Dbp Di-N-Butyl Phthalate)
93 25340-17-4 Diethylbenzene
94 111-46-6 Diethylene Glycol
95 112-34-5 Diethylene Glycol Monobutyl Ether
96 84-69-5 Diisobutyl Phthalate
97 28553-12-0 Diisononyl Phthalate
98 1119-40-0 Dimethyl Glutarate
51Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
99 131-11-3 Dimethyl Phthalate (Dmp)
100 106-65-0 Dimethyl Succinate
101 See Schedule 8 in OReg 41905 Dioxins Furans And Dioxin-Like Pcbs
102 64742-47-8 Distillates (Petroleum) Hydrotreated Light
103 64741-44-2 Distillates (Petroleum) Straight-Run Middle
104 64-17-5 Ethanol (Ethyl Alcohol)
105 141-78-6 Ethyl Acetate
106 100-41-4 Ethyl Benzene
107 763-69-9 Ethyl-3-Ethoxy Propionate
108 74-85-1 Ethylene
109 111-76-2 Ethylene Glycol Butyl Ether (Butyl Cellosolve)
110 111-55-7 Ethylene Glycol Diacetate
111 122-99-6 Ethylene Glycol Monophenyl Ether
112 67762-63-4 Fatty Acids Tall-Oil Bu Esters
113 1309-37-1 Ferric Oxide
114 206-44-0 Fluoranthene - As B[A]P
115 7664-39-3 Fluorides (As HF) ndash Gaseous (Growing Season)
116 7664-39-3 Fluorides (As HF) ndash Total (Growing Season)
117 7664-39-3 Fluorides (As HF) ndash Total (Non-Growing Season)
118 50-00-0 Formaldehyde
119 64-18-6 Formic Acid
120 98-00-0 Furfuryl Alcohol
121 7440-55-3 Gallium [And Other Compounds]
122 96-48-0 Gamma-Butyrolactone
123 7782-42-5 Graphite
52Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
124 28182-81-2 Hdi Polyisocyanate (Hdi-Bt amp Hdi-Ic)
125 142-82-5 Heptane Nshy
126 118-74-1 Hexachlorobenzene
127 822-06-0 Hexamethylene Diisocyanate (Hdi) Monomer
128 110-54-3 Hexane N- (N-Hexane And Hexane Isomers Only)
129 110-54-3 Hexane N- (Part Of A Mixture)
130 627-93-0 Hexanedioic Acid Dimethyl Ester
131 112926-00-8 Hydrated Silica
132 7647-01-0 Hydrogen Chloride
133 74-90-8 Hydrogen Cyanide
134 7722-84-1 Hydrogen Peroxide
135 7783-06-4 Hydrogen Sulphide
136 496-11-7 Indane
137 193-39-5 Indeno(123-Cd)Pyrene - As B[A]P
138 7440-74-6 Indium [And Other Compounds]
139 7439-89-6 Iron [And Other Compounds]
140 15438-31-0 Iron ion Fe+2
141 1317-61-9 Iron Oxide (Fe3O4)
142 110-19-0 Isobutyl Acetate
143 4098-71-9 Isophorone Diisocyanate
144 67-63-0 Isopropanol (Isopropyl Alcohol)
145 98-82-8 Isopropyl Benzene
146 8008-20-6 Kerosine (Petroleum)
147 64742-81-0 Kerosine (Petroleum) Hydrodesulfurized
148 7439-91-0 Lanthanum
53Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
149 7439-92-1 Lead And Lead Compounds
150 68920-61-6 Light Oil (Coal) Coke Oven Distn Residues
151 8032-32-4 Ligroine
152 8001-26-1 Linseed Oil
153 67746-08-1 Linseed Oil Polymd
154 68476-85-7 Liquid Petroleum Gas
155 7439-95-4 Magnesium [And Other Compounds] (excluding Magnesium Carbonate Magnesium Chloride Magnesium Oxide and Magnesium Stearate)
156 546-93-0 Magnesium Carbonate
157 7786-30-3 Magnesium Chloride
158 1309-48-4 Magnesium Oxide
159 557-04-0 Magnesium Stearate
160 7439-96-5 Manganese And Manganese Compounds
161 7439-97-6 Mercury (As Hg) ndash Alkyl Compounds
162 7439-97-6 Mercury (Hg) [And Other Compounds]
163 74-82-8 Methane
164 101-68-8 Methane Diphenyl Diisocyanate (Mdi Monomer)
165 67-56-1 Methanol (Methyl Alcohol)
166 70657-70-4 Methoxy-1-Propyl Acetate 2shy
167 78-93-3 Methyl Ethyl Ketone (2-Butanone)
168 1338-23-4 Methyl Ethyl Ketone Peroxide
169 107-31-3 Methyl Formate
170 108-10-1 Methyl Isobutyl Ketone
171 107-87-9 Methyl Propyl Ketone
172 872-50-4 Methyl-2-Pyrrolidone Nshy
173 5124-30-1 Methylene Bis(4-Cyclohexylisocyanate)
54Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
174 101-77-9 Methylene Dianiline
175 12001-26-2 Mica
176 See definition in OReg 41905 Mineral Spirits
177 7439-98-7 Molybdenum [And Other Compounds]
178 1302-93-8 Mullite (Al6O5(SiO4)2)
179 108-38-3 M-Xylene
180 1760-24-3 N-(3-Trimethoxysilylpropyl)-Ethylenediamine
181 64741-65-7 Naphtha (Petroleum) Heavy Alkylate
182 64742-82-1 Naphtha (Petroleum) Hydrodesulfurized Heavy
183 64742-48-9 Naphtha (Petroleum) Hydrotreated Heavy
184 64742-49-0 Naphtha (Petroleum) Hydrotreated Light
185 68527-24-2 Naphtha (Petroleum) Light Steam-Cracked Arom C5-12 Cycloalkadiene Fraction Polymers
186 91-20-3 Naphthalene
187 575-41-7 Naphthalene 13-Dimethylshy
188 571-58-4 Naphthalene 14-Dimethylshy
189 2245-38-7 Naphthalene 167-Trimethylshy
190 569-41-5 Naphthalene 18-Dimethylshy
191 581-40-8 Naphthalene 23-Dimethylshy
192 581-42-0 Naphthalene 26-Dimethylshy
193 582-16-1 Naphthalene 27-Dimethylshy
194 7440-00-8 Neodymium [And Other Compounds]
195 7440-02-0 Nickel And Nickel Compounds
196 7440-03-1 Niobium [And Other Compounds]
197 14797-55-8 Nitrates
198 98-95-3 Nitrobenzene
55Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
199 7727-37-9 Nitrogen
200 10102-43-9 Nitrogen Oxide (NO)
201 10102-44-0 Nitrogen Oxides
202 10024-97-2 Nitrous Oxide
203 - Organic Carbon
204 95-48-7 Orthocresol
205 144-62-7 Oxalic Acid
206 25085-99-8 Oxirane 22-[(1-Methylethylidene) Bis(41shyPhenyleneoxymethylene)]Bis- Homopolymer
207 90438-79-2 Oxo-Heptyl Acetate
208 95-47-6 O-Xylene
209 7440-05-3 Palladium[And Other Compounds]
210 198-55-0 Perylene
211 8030-30-6 Petroleum Ether
212 68476-86-8 Petroleum Gases Liquefied Sweetened
213 85-01-8 Phenanthrene - As B[A]P
214 108-95-2 Phenol
215 9003-35-4 Phenol-Formaldehyde Resin
216 103-71-9 Phenyl Isocyanate
217 7664-38-2 Phosphoric Acid
218 7723-14-0 Phosphorus
219 147-14-8 Pigment Blue 15
220 7440-06-4 Platinum [And Other Compounds]
221 65530-85-0 Poly(Difluoromethylene) Α-(Cyclohexylmethyl)-ΩshyHydroshy
222 9004-82-4 Poly(Oxy-12-Ethanediyl) Α-Sulfo-Ω-(Dodecyloxy)- Sodium Salt
56Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 20th 2018
Number CAS Number Contaminant Name
223 25723-16-4 Poly[Oxy(Methyl-12-Ethanediyl)] Α-Hydro-ΩshyHydroxy- Ether With 2-Ethyl-2-(Hydroxymethyl)-13shyPropanediol (31)
224 63148-62-9 Polydimethylsiloxanes
225 9016-45-9 Polyethylene Glycol Nonylphenyl Ether
226 9016-87-9 Polymeric Methane Diphenyl Diisocyanate (Pmdi)
227 7440-09-7 Potassium [And Other Compounds]
228 7447-40-7 Potassium Chloride (KCl)
229 151-50-8 Potassium Cyanide
230 1310-58-3 Potassium Hydroxide
231 7757-79-1 Potassium Nitrate
232 12136-45-7 Potassium Oxide (K2O)
233 74-98-6 Propane
234 123-38-6 Propionaldehyde
235 108-65-6 Propylene Glycol Monomethyl Ether Acetate
236 106-42-3 P-Xylene
237 129-00-0 Pyrene - As B[A]P
238 2057-49-0 Pyridine 4-(3-Phenylpropyl)shy
239 71011-26-2 Quaternary Ammonium Compounds Benzyl(Hydrogenated Tallow Alkyl)Dimethyl Chlorides Compds With Hectorite
240 73891-99-3 Rape Oil Me Ester
241 108-46-3 Resorcinol
242 7440-16-6 Rhodium [And Other Compounds]
243 8050-09-7 Rosin
244 7440-17-7 Rubidium [And Other Compounds]
245 7440-20-2 Scandium [And Other Compounds]
246 7782-49-2 Selenium [And Other Compounds]
57Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
247 14464-46-1 Silica - Respirable (lt10 microm Diameter) Cristabolite
248 14808-60-7 Silica - Respirable (lt10 microm Diameter) Quartz
249 16893-85-9 Silicate(2-) Hexafluoro- Disodium
250 1312-76-1 Silicic Acid Potassium Salt
251 1344-09-8 Silicic Acid Sodium Salt
252 7440-21-330194 12597-37shy40 Silicon
253 7631-86-9 Silicon Dioxide
254 71750-80-6 Siloxanes And Silicones Di-Me [[[3-[(2shyAminoethyl)Amino] Propyl]Dimethoxysilyl]Oxy]shyTerminated
255 68554-67-6 Siloxanes And Silicones Di-Me Polymers With Me Silsesquioxanes Hydroxy-Terminated
256 7440-22-4 Silver [And Other Compounds]
257 7440-23-5 Sodium [And Other Compounds]
258 497-19-8 Sodium Carbonate
259 1310-73-2 Sodium Hydroxide
260 12401-86-4 Sodium Monoxide
261 7631-99-4 Sodium Nitrate
262 1313-59-3 Sodium Oxide (Na2O)
263 1330-43-4 Sodium Tetraborate
264 64742-96-7 Solvent Naphtha (Petroleum) Heavy Aliphatic
265 64742-94-5 Solvent Naphtha (Petroleum) Heavy Aromatic
266 64742-89-8 Solvent Naphtha (Petroleum) Light Aliph
267 64742-88-7 Solvent Naphtha (Petroleum) Medium Aliph
268 8052-41-3 Stoddard Solvent
269 7440-24-6 Strontium [And Other Compounds]
270 18480-07-4 Strontium Hydroxide
58Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
271 1314-11-0 Strontium Oxide
272 100-42-5 Styrene
273 7704-34-9 Sulfur Elemental
274 - Sulphates
275 7446-09-5 Sulphur Dioxide
276 7664-93-9 Sulphuric Acid
277 - Suspended Particulate Matter (lt 44 microm Diameter)
278 112945-52-5 Synthetic Amorphous Silica
279 14807-96-6 Talc - Fibrous
280 7440-25-7 Tantalum [And Other Compounds]
281 68131-40-8 Tergitol 15-S-4
282 7440-28-0 Thallium [And Other Compounds]
283 7440-31-5 Tin [And Other Compounds]
284 7440-32-6 Titanium [And Other Compounds]
285 13463-67-7 Titanium Dioxide
286 108-88-3 Toluene
287 - Total Aldehydes (C2-C25)
288 - Total Amines
289 102-76-1 Triacetin
290 79-01-6 Trichloroethylene (Tce)
291 121-44-8 Triethylamine
292 112-27-6 Triethylene Glycol
293 526-73-8 Trimethylbenzene 123- (Individual Isomer Or Trimethylbenzene Mixture)
294 95-63-6 Trimethylbenzene 124- (Individual Isomer Or Trimethylbenzene Mixture)
295 108-67-8 Trimethylbenzene 135- (Individual Isomer Or
59Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
Trimethylbenzene Mixture)
296 15625-89-5 Trimethylolpropane Triacrylate
297 420-56-4 Trimethylsilyl Fluoride
298 7440-62-2 Vanadium [And Other Compounds]
299 1330-20-7 Xylenes
300 7440-65-5 Yttrium [And Other Compounds]
301 7440-66-6 Zinc [And Other Compounds]
302 7646-85-7 Zinc Chloride
303 557-05-1 Zinc Stearate
304 14940-68-2 Zircon (Zr(SiO4))
305 7440-67-7 Zirconium [And Other Compounds]
306 1314-23-4 Zirconium Oxide (ZrO2)
Appendix 2-2 Priority Metals
Number CAS Number Contaminant Name
1 7440-38-2 Arsenic And Compounds
2 7440-41-7 Beryllium And Compounds
3 7440-43-9 Cadmium And Cadmium Compounds
4 7440-47-3 Chromium And Chromium Compounds (Metallic Divalent And Trivalent)
5 7440-47-3 Chromium Compounds (Hexavalent)
6 7439-92-1 Lead and Lead Compounds
7 7439-96-5 Manganese And Manganese Compounds
8 7439-97-6 Mercury (As Hg) ndash Alkyl Compounds
9 7439-97-6 Mercury (Hg) [And Other Compounds]
10 7440-02-0 Nickel And Nickel Compounds
60Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
11 7440-62-2 Vanadium [And Other Compounds]
Appendix 2-3 Suspended Particulate Matter
Number CAS Number Contaminant Name
1 996-35-0 2-Propanamine NN-Dimethylshy
2 68540-66-9 2-Propenoic Acid Polymer With Ethyl 2-PropenoateAnd Isooctyl 2-Propenoate
3 7429-90-5 Aluminum [And Other Compounds]
4 1344-28-1 Aluminum Oxide
5 637-12-7 Aluminum Tristearate
6 7440-36-0 Antimony [And Other Compounds]
7 7440-38-2 Arsenic And Compounds
8 7440-39-3 Barium [And Other Compounds]
9 10361-37-2 Barium Chloride (BaCl2)
10 1302-78-9 Bentonite
11 5873-54-1 Benzene 1-Isocyanato-2-[(4shyIsocyanatophenyl)Methyl]shy
12 7440-41-7 Beryllium And Compounds
13 7440-69-9 Bismuth [And Other Compounds]
14 14075-53-7 Borate(1-) Tetrafluoro- Potassium
15 1303-96-4 Borax
16 7440-42-8 Boron
17 7726-95-6 Bromine
18 1328-53-6 CI Pigment Green 7
19 7440-43-9 Cadmium And Cadmium Compounds
20 7440-70-2 Calcium [And Other Compounds]
61Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
21 75-20-7 Calcium Carbide
22 471-34-1 Calcium Carbonate
23 10043-52-4 Calcium Chloride Anhydrous
24 592-01-8 Calcium Cyanide (As Total Salt)
25 7789-75-5 Calcium Fluoride (CaF2)
26 1305-62-0 Calcium Hydroxide
27 1305-78-8 Calcium Oxide
28 1592-23-0 Calcium Stearate
29 7440-44-0 Carbon
30 1333-86-4 Carbon Black
31 7782-50-5 Chlorine
32 7440-47-3 Chromium And Chromium Compounds (Metallic Divalent And Trivalent)
33 7440-47-3 Chromium Compounds (Hexavalent)
34 7440-48-4 Cobalt [And Other Compounds]
35 65996-77-2 Coke (Coal)
36 7440-50-8 Copper [And Other Compounds]
37 80-15-9 Cumene Hydroperoxide
38 41556-26-7 Decanedioic Acid Bis(12266-Pentamethyl-4shyPiperidinyl) Ester
39 1309-37-1 Ferric Oxide
40 7440-55-3 Gallium [And Other Compounds]
41 7782-42-5 Graphite
42 28182-81-2 Hdi Polyisocyanate (Hdi-Bt amp Hdi-Ic)
43 822-06-0 Hexamethylene Diisocyanate (Hdi) Monomer
44 112926-00-8 Hydrated Silica
45 7440-74-6 Indium [And Other Compounds]
62Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
46 7439-89-6 Iron [And Other Compounds]
47 15438-31-0 Iron ion Fe+2
48 1317-61-9 Iron Oxide (Fe3O4)
49 7439-91-0 Lanthanum
50 7439-92-1 Lead and Lead Compounds
51 7439-95-4 Magnesium [And Other Compounds] (excluding Magnesium Carbonate Magnesium Chloride Magnesium Oxide and Magnesium Stearate)
52 546-93-0 Magnesium Carbonate
53 7786-30-3 Magnesium Chloride
54 1309-48-4 Magnesium Oxide
55 557-04-0 Magnesium Stearate
56 7439-96-5 Manganese And Manganese Compounds
57 7439-97-6 Mercury (As Hg) ndash Alkyl Compounds
58 7439-97-6 Mercury (Hg) [And Other Compounds]
59 12001-26-2 Mica
60 7439-98-7 Molybdenum [And Other Compounds]
61 1302-93-8 Mullite (Al6O5(Sio4)2)
62 1760-24-3 N-(3-Trimethoxysilylpropyl)-Ethylenediamine
63 68527-24-2 Naphtha (Petroleum) Light Steam-Cracked Arom C5-12 Cycloalkadiene Fraction Polymers
64 7440-00-8 Neodymium [And Other Compounds]
65 7440-02-0 Nickel And Nickel Compounds
66 7440-03-1 Niobium [And Other Compounds]
67 14797-55-8 Nitrates
68 Not Applicable Organic Carbon
69 25085-99-8 Oxirane 22-[(1-Methylethylidene) Bis(41shyPhenyleneoxymethylene)]Bis- Homopolymer
63Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
70 7440-05-3 Palladium [And Other Compounds]
71 9003-35-4 Phenol-Formaldehyde Resin
72 7723-14-0 Phosphorus
73 147-14-8 Pigment Blue 15
74 7440-06-4 Platinum [And Other Compounds]
75 65530-85-0 Poly(Difluoromethylene) Α-(Cyclohexylmethyl)-ΩshyHydroshy
76 63148-62-9 Polydimethylsiloxanes
77 7440-09-7 Potassium [And Other Compounds]
78 7447-40-7 Potassium Chloride (KCl)
79 151-50-8 Potassium Cyanide
80 1310-58-3 Potassium Hydroxide
81 7757-79-1 Potassium Nitrate
82 12136-45-7 Potassium Oxide (K2O)
83 71011-26-2 Quaternary Ammonium Compounds Benzyl(Hydrogenated Tallow Alkyl)Dimethyl Chlorides Compds With Hectorite
84 108-46-3 Resorcinol
85 7440-16-6 Rhodium [And Other Compounds]
86 8050-09-7 Rosin
87 7440-17-7 Rubidium [And Other Compounds]
88 7440-20-2 Scandium [And Other Compounds]
89 7782-49-2 Selenium [And Other Compounds]
90 14464-46-1 Silica - Respirable (lt10 microm Diameter) Cristabolite
91 14808-60-7 Silica - Respirable (lt10 microm Diameter) Quartz
92 16893-85-9 Silicate(2-) Hexafluoro- Disodium
93 1312-76-1 Silicic Acid Potassium Salt
64Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
94 1344-09-8 Silicic Acid Sodium Salt
95 7440-21-330194 12597-37shy40 Silicon
96 7631-86-9 Silicon Dioxide
97 7440-22-4 Silver [And Other Compounds]
98 7440-23-5 Sodium [And Other Compounds]
99 497-19-8 Sodium Carbonate
100 1310-73-2 Sodium Hydroxide
101 12401-86-4 Sodium Monoxide
102 7631-99-4 Sodium Nitrate
103 1313-59-3 Sodium Oxide (Na2O)
104 1330-43-4 Sodium Tetraborate
105 7440-24-6 Strontium [And Other Compounds]
106 18480-07-4 Strontium Hydroxide
107 1314-11-0 Strontium Oxide
108 7704-34-9 Sulfur Elemental
109 Not Applicable Sulphates
110 Not Applicable Suspended Particulate Matter (lt 44 microm Diameter)
111 112945-52-5 Synthetic Amorphous Silica
112 14807-96-6 Talc - Fibrous
113 7440-25-7 Tantalum [And Other Compounds]
114 7440-28-0 Thallium [And Other Compounds]
115 7440-31-5 Tin [And Other Compounds]
116 7440-32-6 Titanium [And Other Compounds]
117 13463-67-7 Titanium Dioxide
118 7440-62-2 Vanadium [And Other Compounds]
65Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
119 7440-65-5 Yttrium [And Other Compounds]
120 7440-66-6 Zinc [And Other Compounds]
121 7646-85-7 Zinc Chloride
122 557-05-1 Zinc Stearate
123 14940-68-2 Zircon (Zr(SiO4))
124 7440-67-7 Zirconium [And Other Compounds]
125 1314-23-4 Zirconium Oxide (ZrO2)
Appendix 2-4 Volatile Organic Compounds
Number CAS Number Contaminant Name
1 95-93-2 1245-Tetramethylbenzene
2 33329-35-0 13-Propanediamine NN-Bis[3shy(Dimethylamino)Propyl]-NN-Dimethylshy
3 616-47-7 1-Methylimidazole
4 90-12-0 1-Methylnaphthalene
5 1120-36-1 1-Tetradecene
6 90-72-2 246-Tris(Dimethylaminomethyl)Phenol
7 91-57-6 2-Methylnaphthalene
8 617-94-7 2-Phenylisopropanol
9 110-26-9 2-Propenamide NN-Methylenebisshy
10 208-96-8 Acenaphthylene - As B[A]P
11 75-07-0 Acetaldehyde
12 64-19-7 Acetic Acid
13 67-64-1 Acetone
14 98-86-2 Acetophenone
66Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
15 260-94-6 Acridine
16 107-02-8 Acrolein
17 79-10-7 Acrylic Acid
18 68551-13-3 Alcohols C12-15 Ethoxylated Propoxylated
19 7664-41-7 Ammonia
20 62-53-3 Aniline
21 120-12-7 Anthracene - As B[A]P
22 191-26-4 Anthranthrene - As B[A]P
23 70693-06-0 Aromatic Hydrocarbons C9-11
24 64742-95-6 Aromatic Naphtha Type I
25 71-43-2 Benzene
26 26447-40-5 Benzene 11-Methylenebis(Isocyanatoshy
27 527-53-7 Benzene 1235-Tetramethylshy
28 141-93-5 Benzene 13-Diethylshy
29 105-05-5 Benzene 14-Diethylshy
30 104-15-4 Benzenesulfonic Acid 4-Methylshy
31 25321-41-9 Benzenesulfonic Acid Dimethylshy
32 56-55-3 Benzo(A)Anthracene - As B[A]P
33 203-33-8 Benzo(A)Fluoranthene - As B[A]P
34 50-32-8 Benzo(A)Pyrene
35 205-99-2 207-08-9 Benzo(B)+(K)Fluoranthene ndash As B[A]P
36 205-99-2 Benzo(B)Fluoranthene ndash As B[A]P
37 192-97-2 Benzo(E)Pyrene - As B[A]P
38 191-24-2 Benzo(GHI)Perylene - As B[A]P
39 207-08-9 Benzo(K)Fluoranthene ndash As B[A]P
67Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
40 106-97-8 Butane
41 123-86-4 Butyl Acetate Nshy
42 86-74-8 Carbazole
43 218-01-9 Chrysene - As B[A]P
44 1319-77-3 Cresols
45 53-70-3 Dibenz(AH)Anthracene ndash As B[A]P
46 53-70-3 215-58-7 Dibenzo(AH)+(AC) Anthracene - As B[A]P
47 132-64-9 Dibenzofuran
48 84-74-2 Dibutyl Phthalate (Dbp Di-N-Butyl Phthalate)
49 25340-17-4 Diethylbenzene
50 111-46-6 Diethylene Glycol
51 112-34-5 Diethylene Glycol Monobutyl Ether
52 84-69-5 Diisobutyl Phthalate
53 28553-12-0 Diisononyl Phthalate
54 1119-40-0 Dimethyl Glutarate
55 131-11-3 Dimethyl Phthalate (Dmp)
56 106-65-0 Dimethyl Succinate
57 See Schedule 8 in OReg 41905 Dioxins Furans And Dioxin-Like Pcbs
58 64742-47-8 Distillates (Petroleum) Hydrotreated Light
59 64741-44-2 Distillates (Petroleum) Straight-Run Middle
60 64-17-5 Ethanol (Ethyl Alcohol)
61 141-78-6 Ethyl Acetate
62 100-41-4 Ethyl Benzene
63 763-69-9 Ethyl-3-Ethoxy Propionate
64 74-85-1 Ethylene
68Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
65 111-76-2 Ethylene Glycol Butyl Ether (Butyl Cellosolve)
66 111-55-7 Ethylene Glycol Diacetate
67 122-99-6 Ethylene Glycol Monophenyl Ether
68 206-44-0 Fluoranthene - As B[A]P
69 50-00-0 Formaldehyde
70 64-18-6 Formic Acid
71 98-00-0 Furfuryl Alcohol
72 96-48-0 Gamma-Butyrolactone
73 142-82-5 Heptane Nshy
74 118-74-1 Hexachlorobenzene
75 110-54-3 Hexane N- (N-Hexane And Hexane Isomers Only)
76 110-54-3 Hexane N- (Part Of A Mixture)
77 627-93-0 Hexanedioic Acid Dimethyl Ester
78 74-90-8 Hydrogen Cyanide
79 7783-06-4 Hydrogen Sulphide
80 496-11-7 Indane
81 193-39-5 Indeno(123-Cd)Pyrene - As B[A]P
82 110-19-0 Isobutyl Acetate
83 4098-71-9 Isophorone Diisocyanate
84 67-63-0 Isopropanol (Isopropyl Alcohol)
85 98-82-8 Isopropyl Benzene
86 8008-20-6 Kerosine (Petroleum)
87 64742-81-0 Kerosine (Petroleum) Hydrodesulfurized
88 8032-32-4 Ligroine
89 68476-85-7 Liquid Petroleum Gas
69Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
90 74-82-8 Methane
91 101-68-8 Methane Diphenyl Diisocyanate (Mdi Monomer)
92 67-56-1 Methanol (Methyl Alcohol)
93 70657-70-4 Methoxy-1-Propyl Acetate 2shy
94 78-93-3 Methyl Ethyl Ketone (2-Butanone)
95 1338-23-4 Methyl Ethyl Ketone Peroxide
96 107-31-3 Methyl Formate
97 108-10-1 Methyl Isobutyl Ketone
98 107-87-9 Methyl Propyl Ketone
99 872-50-4 Methyl-2-Pyrrolidone Nshy
100 5124-30-1 Methylene Bis(4-Cyclohexylisocyanate)
101 101-77-9 Methylene Dianiline
102 See definition in OReg 41905 Mineral Spirits
103 108-38-3 M-Xylene
104 64741-65-7 Naphtha (Petroleum) Heavy Alkylate
105 64742-82-1 Naphtha (Petroleum) Hydrodesulfurized Heavy
106 64742-48-9 Naphtha (Petroleum) Hydrotreated Heavy
107 64742-49-0 Naphtha (Petroleum) Hydrotreated Light
108 91-20-3 Naphthalene
109 575-41-7 Naphthalene 13-Dimethylshy
110 571-58-4 Naphthalene 14-Dimethylshy
111 2245-38-7 Naphthalene 167-Trimethylshy
112 569-41-5 Naphthalene 18-Dimethylshy
113 581-40-8 Naphthalene 23-Dimethylshy
114 581-42-0 Naphthalene 26-Dimethylshy
70Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
115 582-16-1 Naphthalene 27-Dimethylshy
116 98-95-3 Nitrobenzene
117 95-48-7 Orthocresol
118 90438-79-2 Oxo-Heptyl Acetate
119 95-47-6 O-Xylene
120 198-55-0 Perylene
121 8030-30-6 Petroleum Ether
122 68476-86-8 Petroleum Gases Liquefied Sweetened
123 85-01-8 Phenanthrene - As B[A]P
124 108-95-2 Phenol
125 103-71-9 Phenyl Isocyanate
126 25723-16-4 Poly[Oxy(Methyl-12-Ethanediyl)] Α-Hydro-ΩshyHydroxy- Ether With 2-Ethyl-2-(Hydroxymethyl)-13shyPropanediol (31)
127 9016-45-9 Polyethylene Glycol Nonylphenyl Ether
128 9016-87-9 Polymeric Methane Diphenyl Diisocyanate (Pmdi)
129 74-98-6 Propane
130 123-38-6 Propionaldehyde
131 108-65-6 Propylene Glycol Monomethyl Ether Acetate
132 106-42-3 P-Xylene
133 129-00-0 Pyrene - As B[A]P
134 2057-49-0 Pyridine 4-(3-Phenylpropyl)shy
135 71750-80-6 Siloxanes And Silicones Di-Me [[[3-[(2shyAminoethyl)Amino] Propyl]Dimethoxysilyl]Oxy]shyTerminated
136 68554-67-6 Siloxanes And Silicones Di-Me Polymers With Me Silsesquioxanes Hydroxy-Terminated
137 64742-96-7 Solvent Naphtha (Petroleum) Heavy Aliphatic
71Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant Name
138 64742-94-5 Solvent Naphtha (Petroleum) Heavy Aromatic
139 64742-89-8 Solvent Naphtha (Petroleum) Light Aliph
140 64742-88-7 Solvent Naphtha (Petroleum) Medium Aliph
141 8052-41-3 Stoddard Solvent
142 100-42-5 Styrene
143 68131-40-8 Tergitol 15-S-4
144 108-88-3 Toluene
145 Not Applicable Total Aldehydes (C2-C25)
146 Not Applicable Total Amines
147 102-76-1 Triacetin
148 79-01-6 Trichloroethylene (Tce)
149 121-44-8 Triethylamine
150 112-27-6 Triethylene Glycol
151 526-73-8 Trimethylbenzene 123- (Individual Isomer Or Trimethylbenzene Mixture)
152 95-63-6 Trimethylbenzene 124- (Individual Isomer Or Trimethylbenzene Mixture)
153 108-67-8 Trimethylbenzene 135- (Individual Isomer Or Trimethylbenzene Mixture)
154 15625-89-5 Trimethylolpropane Triacrylate
155 420-56-4 Trimethylsilyl Fluoride
156 1330-20-7 Xylenes
72Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Appendix 2-5 Hydrogen Chloride and Fluorides (as HF)
Number CAS Number Contaminant Name
1 7664-39-3 Fluorides (As HF) ndash Gaseous (Growing Season) Total (Growing Season) Total (Non-Growing Season)
2 7647-01-0 Hydrogen Chloride
Appendix 2-6 Amines
Number CAS Number Contaminant Name
1 Not Applicable Total Amines
Appendix 2-7 Sulphur Dioxide
Number CAS Number Contaminant Name
1 7446-09-5 Sulphur Dioxide
Appendix 2-8 Lead and Lead Compounds
Number CAS Number Contaminant Name
1 7439-92-1 Lead and Lead Compounds
Record of Publications for Foundries - Industry Standard
Tracking Date Publishing Minister
Version 20
Foundries - Industry Standard
Created March 8 2016 Murray
Version 10
Foundries - Industry Standard
Created December 4 2009 Gerretsen
73Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
CHAPTER 3 - FOREST PRODUCTS ndash INDUSTRY STANDARD
Version 20 Created March 5 2015
Preamble
bull This technical standard is an industry standard as defined in section 1 of O Reg41905
bull With respect to facilities this standard applies to every facility that is part of a classidentified by NAICS code 3211 (Sawmills and Wood Preservation) or 3212 (VeneerPlywood and Engineered Wood Product Manufacturing) other than a facility that is partof the class identified by NAICS code 321114 (Wood Preservation) or 321211(Hardwood Veneer and Plywood Mills)
bull With respect to contaminants this standard applies only to acrolein
bull In accordance with subsection 38(3) of O Reg 41905 compliance with this industrystandard in accordance with subsection 42 (5) or subsection 44(3) may reduce theregulatory burden applicable to facilities in this class
bull All of the sources of contaminant that discharge acrolein that are associated with theabove NAICs codes have been considered in this industry standard As such a personregistered for this industry standard that meets the criteria set out in subsection 42(1) orsubsection 44(1) of OReg 41905 is in general exempt from Part II of the Regulationin respect of the facility and acrolein In other words a facility that is registered underthis industry standard does not have to include any source of contaminant associatedwith the NAICs code that applies to them in any future Emission Summary andDispersion Modelling reports for acrolein (For more information please see theIntroduction to the Technical Standards Publication)
bull This standard contains requirements that relate to the following sources of contaminantbull oriented strand board direct fired rotary dryersbull particle board rotary dryersbull particle board dry dryersbull fiberboard atmospheric refinersbull small-scale lumber kilnsbull full-scale lumber kilnsbull wood-fired combustors
bull With respect to acrolein the publication of this industry standard indicates that thefollowing criteria in paragraph 31 of subsection 38(1) of O Reg 41905 are met(a) with respect to at least two facilities located in Ontario to which this standard
applies it is not economically feasible to comply with section 19 or 20 of O Reg41905 whichever is applicable
(b) compliance in accordance with subsection 42 (5) of O Reg 41905 with thisstandard
1 With respect to acrolein the Minister of the Environment is of the opinion that the criteria set out in paragraph 3 of subsection 38(1) of O Reg 41905 are met
Ontario Ministry of the Environment and Climate Change 74
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(i) is technically and economically feasible with respect to at least one facilitylocated in Ontario to which this industry standard applies and
(ii) will permit efforts that would otherwise be made to comply with section 19 or20 of O Reg 41905 to be put to better use to protect the naturalenvironment having regard to subclause (i) and
(iii) including this industry standard in ldquoTechnical Standards to Manage AirPollutionrdquo is more efficient than having the Director consider separate requestsunder section 32 of O Reg 41905 for approval of alterations to the standardfor acrolein that would otherwise apply to facilities to which this industrystandard applies
Definitions
1 (1) For the purposes of this forest products industry standard
ldquo24-hour block averagerdquo means an average taken over 24 consecutive hours and does notmean a rolling average For example an average of values recorded every hour frommidnight to midnight would be a 24-hour block average
ldquoacroleinrdquo means the contaminant with a CAS Number of 107-02-8
ldquoCAS Nordquo has the same meaning as in section 1 of OReg 41905
ldquodry dryerrdquo means a dryer that dries furnish that has an inlet moisture content less than 50percent (on a dry basis)
ldquodryerrdquo means a device that removes moisture and includes an oriented strand board directfired rotary dryer particle board rotary dryer and particle board dry dryer
ldquodryer exhaust diversionrdquo means the diversion of a portion of the total volumetric flow rate ofthe dryer exhaust to an operating source of combustion
ldquoexisting facilityrdquo means a facility
(i) the construction of which was completed or began on or before February 12010 or
(ii) for which an application was made on or before February 1 2010 for acertificate of approval in respect of the facility
ldquofurnishrdquo means wood fibres particles or strands used for making board
ldquogreen sortingrdquo means the lumber industry practice of on-site ranking of raw (green) wood feedstock based on the relative moisture content of the wood
ldquoindustry standardrdquo has the same meaning as in section 1 of O Reg 41905
ldquomajor modificationrdquo means any process added to the facility after February 1 2010 which
Ontario Ministry of the Environment and Climate Change 75
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
includes a source of contaminant listed in subsection 3(1) and any replacement after February 1 2010 of a source of contaminant listed in subsection 3(1) It does not include repairs or maintenance For example a new or replaced dryer at a facility would be a major modification
ldquoMOErdquo means the Ontario Ministry of the Environment
ldquoNAICSrdquo has the same meaning as in section 1 of OReg 41905
ldquonew facilityrdquo means a facility the construction of which began after February 1 2010 and no application was made on or before that day for a certificate of approval in respect of the facility
ldquoO Reg 41905rdquo means Ontario Regulation 41905 Air Pollution ndash Local Air Quality (as amended) made under the Environmental Protection Act
ldquorefinerrdquo means an atmospheric refiner not a pressurized refiner (sealed vessel)
ldquosawmill facilityrdquo means a facility at which lumber is produced and which is part of a class identified by NAICS code 3211(Sawmills and Wood Preservation) but does not include NAICS code 321114 (Wood Preservation) Examples of sawmill facilities include sawmills and shingle and shake mills
ldquotechnical standardrdquo has the same meaning as in section 1 of O Reg 41905
ldquoveneer plywood or engineered wood products manufacturing facilityrdquo means a facility at which veneer plywood or an engineered wood product is produced and which is part of a class identified by NAICS code 3212 (Veneer Plywood and Engineered Wood Product Manufacturing) but does not include NAICS code 321211 (Hardwood Veneer and Plywood Mills) Examples of veneer plywood or engineered wood products manufacturing facilities include softwood veneer and plywood mills structural wood product manufacturing particle board and fibreboard mills waferboard mills and
ldquotemperature sensor validationrdquo means the check of a process temperature sensor with a second temperature sensor (eg different or extra) placed nearby the process temperature sensor that must yield a reading within 20oC of the first process temperature sensor
(2) References in this industry standard to per cent moisture content of furnish is to beexpressed on dry basis and for the purposes of this industry standard an amount of percent moisture content on a wet basis shall be converted to dry basis in accordance with thefollowing formula
A = [B100] [1-(B100)] x100
where
A = the per cent moisture content of the furnish on a dry basis
and B = the per cent moisture content of the furnish on a wet
basis and
Ontario Ministry of the Environment and Climate Change 76
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Application
2 (1) A person who registers on the Ministrys Technical Standards Registry - Air Pollution bythe date listed in Column 2 of Table 3-2A in respect of (i) this industry standard (ii) afacility of a type listed in Column 1 and (iii) acrolein shall comply with the sections listedin Column 3 by the dates specified in Column 4
Table 3-2A Application
Item Column 1
Facility Type
Column 2
RegistrationDate
Column 3
Section of the Industry Standard
Column 4
Date for Compliance with section
1 Existing Facility
Before February 1
123567910 August 1 2011
2011 4 February 1 2015
2 Existing Facility
On or after February 1 2011
123567910 The later of (i) the date the facility applies for registration and (ii) August 1 2011
4 The later of (i) the date the facility applies for registration and (ii) February 1 2015
3 New Facility On or after February 1 2010
All The later of (i) the date the facility applies for registration and (ii) February 1 2011
4 Registered Existing or New Facility that has a major modification after February 1 2010
--shy
All The later of (i) the date that any source of contaminant related to the major modification begins operation and (ii) February 1 2011
Operational Practices
3 (1) This section applies to
1 a veneer plywood and engineered wood products manufacturing facility that hasany of the following sources of contaminant that discharge acrolein
i oriented strand board direct fired rotary dryersii particle board rotary dryeriii particle board dry dryersiv fiberboard atmospheric refiners
wood-fired combustors and
2 a sawmill facility that has any of the following sources of contaminant that dischargeacrolein
77Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
i a small-scale lumber kilnii full-scale lumber kilniii wood-fired combustors
(2) A person who discharges or causes or permits the discharge of a contaminantmentioned in subsection (1) shall develop and implement written procedures to ensure thedischarge of acrolein is minimized for each source of contaminant described in subsection(1)
(3) The procedures mentioned in subsection (2) shall include for each source ofcontaminant mentioned in subsection (1) procedures to ensure that
(a) relevant operating parameters are identified for the source of contaminant whichmay include temperature and moisture content
(b) for each parameter identified in clause (a) a range of values is established inwhich the source of contaminant will be considered to be operating normally
(c) the source of contaminant is monitored at established intervals to ensure that eachparameter identified in clause (a) is within the range of values identified in clause(b)
(d) the date time and value of the parameters identified in clause (a) are recordedeach time the source of contaminant is monitored as required by clause (c)
(e) any device used for monitoring is inspected on a regular basis to ensure properoperation and calibrated at least annually or when technically feasible
(f) the source of contaminant is inspected for any damage and to ensure properoperation on a regular basis
(g) the date and results of inspections required by clause (e) and (f) are recorded(h) maintenance activities are performed on the source of contaminant on a regular
basis(i) the date and details of the maintenance activities required by clause (h) are
recorded(j) discharges from the source of contaminant are minimized during start up shut
down and malfunction of the equipment and(k) recurring malfunctions of the source of contaminant are brought to the attention of
the highest ranking person at the facility mentioned in subsection (1) and areaddressed promptly
(l) the following information with respect to a deviation from a requirement of thisindustry standard is recordedi the date time and duration of the deviationii the values mentioned in clause (d) for the duration of the deviation including
a comparison to the range of values required to be established under clause(b)
iii an explanation of the suspected cause of the deviationiv a description of the corrective actions taken and the dates the corrective
actions were completed andv the names of the personnel assigned to complete the corrective actions
(4) Subsection (2) does not apply for a period of 6 months after the installation of a source
Ontario Ministry of the Environment and Climate Change 78
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
of contaminant if
(a) the source of contaminant is installed after the date on which a facility mentioned insubsection (1) is registered with respect to this industry standard and
(b) the facility mentioned in subsection (1) is meeting the requirements set out insubsection 42(5) or subsection 44(3)of O Reg 41905 whichever applies
Veneer Plywood and Engineered Wood Products ndashDryer Operating Parameters
4 (1) This section applies to a veneer plywood and engineered wood products manufacturingfacility that has any of the following sources of contaminant that discharge acrolein
i oriented strand board direct fired rotary dryersii particle board rotary dryeriii particle board dry dryers
(2) Subject to subsection (4) the parameters required to be identified in clause (a) ofsubsection 3(3) shall include
(a) the parameters set out in Column 1 of Table 3-1 or(b) the parameters set out in Column 1 of Table 3-2
(3) Subject to subsections (4) and (5) the range of values required to be established inclause (b) of subsection 3(3) shall include
(a) the range of values set out in Column 3 of Table 3-1 if the parameters required tobe identified in clause (a) of subsection 3(3) are the parameters set out in clause(2)(a) or
(b) the range of values set out in Column 3 of Table 3-2 if the parameters required tobe identified in clause (a) of subsection 3(3) are the parameters set out in clause(2)(b)
(4) On or before February 1 2020 subsections (2) and (3) do not apply to a source ofcontaminant mentioned in subsection (1) at an existing facility mentioned in subsection (1)if the procedures mentioned in subsection 3(2) include procedures to ensure that thefollowing parameters are optimized to reduce discharges from each source of contaminantmentioned in subsection (1) as much as practicable
1 moisture consistency2 flake size3 inlet moisture content of furnish on a dry basis
(5) On or before February 1 2020 subsection (3) does not apply to a source of contaminantmentioned in subsection (1) at an existing facility mentioned in subsection (1) if the rangesof values required to be established in clause (b) of subsection 3(3) include
(a) the range of values set out in Column 2 of Table 3-1 if the parameters required tobe identified in clause (a) of subsection 3(3) are the parameters set out in clause(2)(a) or
(b) the range of values set out in Column 2 of Table 3-2 if the parameters required tobe identified in clause (a) of subsection 3(3) are the parameters set out in clause(2)(b)
Ontario Ministry of the Environment and Climate Change 79
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Veneer Plywood and Engineered Wood Products - Monitoring
5 (1) This section applies to a veneer plywood and engineered wood products manufacturingfacility that has any of the following sources of contaminant that discharge acrolein
i oriented strand board direct fired rotary dryersii particle board rotary dryeriii particle board dry dryer
(2) The intervals for monitoring required to be established in clause (c) of subsection 3(3)shall be
(a) intervals that are at least as frequent as those set out in Column 4 of Table 3-1 ifthe parameters required to be identified in clause (a) of subsection 3(3) are theparameters set out in clause (a) of subsection 4(2) or
(b) intervals that are at least as frequent those as set out in Column 4 of Table 3-2 ifthe parameters required to be identified in clause (a) of subsection 3(3) are theparameters set out in clause (b) of subsection 4(2) or paragraph 3 of subsection4(4)
(3) For the purpose of clause (l) of subsection 3(3) failure to monitor in accordance withsubsection (2) shall be deemed not to be a deviation from clause (c) of subsection 3(3) if atleast 75 of the required recordings were made
(4) For clarity subsection (3) does not relieve a person from making the record required byclause (d) of subsection 3(3) each time the source of contaminant is monitored
Veneer Plywood and Engineered Wood Products - Devices
6 (1) This section applies to a veneer plywood and engineered wood products manufacturingfacility that has identified parameters under clause (b) of subsection 4(2) and that has any ofthe following sources of contaminant that discharge acrolein
i oriented strand board direct fired rotary dryersii particle board rotary dryeriii particle board dry dryer
(2) The devices mentioned in clause (e) of subsection 3(3) shall include the devices set outin Column 1 of Table 3-3 and shall meet the requirements set out in Column 2 of Table 3-3
(3) The inspection required to be performed in clause (e) of subsection 3(3) shall include therequirements in Column 3 of Table 3-3 and be done at least as frequently as set out inColumn 4 of Table 3-3
Ontario Ministry of the Environment and Climate Change 80
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(4) The calibration required to be performed in clause (e) of subsection 3(3) shall include therequirements in Column 5 of Table 3-3 and be done at least as frequently as set out inColumn 6 of Table 3-3
Saw Mills
7 (1) This section applies to a sawmill facility that has a small or full-scale lumber kiln thatdischarges acrolein
(2) The procedures mentioned in subsection 3(2) shall include procedures to ensure thatdischarges from each source of contaminant mentioned in subsection (1) are reduced asmuch as practicable by reducing the long-term average moisture variability of the lumberexiting the kiln
(3) The procedures mentioned in subsection (2) shall address
i the use of air flow bafflingii the use of stickeringiii optimization of in-kiln wood moistureiv the use and optimization of kiln operating control systemsv the use and optimization of humidity tracking andvi the maintenance of air circulation and heat source components
(4) The parameters required to be identified in clause (a) of subsection 3(3) shall include theparameters set out in Column 1 of Table 3-4
(5) The intervals for monitoring required to be established in clause (c) of subsection 3(3)shall intervals that are least as frequent as those set out in Column 2 of Table 3-4
(6) The devices mentioned in clause (e) of subsection 3(3) shall include the devices set outin Column 1 of Table 3-5
(7) The inspection required to be performed in clause (e) of subsection 3(3) shall include therequirements in Column 2 of Table 3-5 and be done at least as frequently as set out inColumn 3 of Table 3-5
(8) The calibration required to be performed in clause (e) of subsection 3(3) shall include therequirements in Column 4 of Table 3-5 and be done at least as frequently as set out inColumn 5 of Table 3-5
Ontario Ministry of the Environment and Climate Change 81
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Sawmills ndash Green Sorting
8 (1) Subject to subsection (4) a person who discharges or causes or permits the dischargeof acrolein from a sawmill facility shall not operate the sawmill facility unless the facility isdesigned and operated to facilitate green sorting
(2) The parameter mentioned in subsection 7(4) shall be deemed to be the moisture contentof green lumber
(3) The devices mentioned in subsection 7(6) shall be deemed to be green lumber moisturemeters
(4) Subsection (1) does not apply to an existing sawmill facility unless there is a majormodification to a sorting process
Summary Reports 9 (1) This section applies to
1 a veneer plywood and engineered wood products manufacturing facility that hasany of the following sources of contaminant that discharge acrolein
i oriented strand board direct fired rotary dryersii particle board rotary dryeriii particle board dry dryersiv fiberboard atmospheric refinersv wood-fired combustors and
2 a sawmill facility that has any of the following sources of contaminant that dischargeacrolein
i a small-scale lumber kilnii full-scale lumber kilniii wood-fired combustors
(2) A person who discharges or causes or permits the discharge of a contaminantmentioned in subsection (1) shall develop and implement written procedures to inform thehighest ranking employee at the facility mentioned in subsection (1) of the performance ofthe facility in relation to the requirements set out in this industry standard
(3) The procedures mentioned in subsection (2) shall include procedures to ensure that thefollowing tables are prepared
(a) a table labelled ldquoOperating Parameter Summary Tablerdquo that sets out the followingi each source of contaminant mentioned in subsection (1) that is part of the
facility mentioned in subsection (1)ii the parameters identified in clause (a) of subsection 3(3) for the source of
contaminant mentioned in paragraph i and
Ontario Ministry of the Environment and Climate Change 82
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
iii for each parameter identified in paragraph ii the range of values establishedunder clause (b) of subsection 3(3)
(b) a table labelled ldquoDeviation Summary Tablerdquo that for the calendar year sets out asummary of the information described in clause (l) of subsection 3(3) and anexplanation of any changes from the summary of the previous year
(c) a table labelled ldquoImplementation Summary Tablerdquo that for the calendar year setsouti a summary of the requirements of this industry standard that need to be metii the timeframe in accordance with section 2 in which the requirements are
required to be met andiii an indication of whether the requirement has been met and if so the date on
which the requirement was met
(4) If during a calendar year there is a change to the information in the table mentioned inclause (a) of subsection (3) not later than March 31 in the following year the table shall beupdated to reflect the change
(5) The procedures mentioned in subsection (2) shall ensure that not later than March 31 ofthe year following the calendar year mentioned in subsection (3) the tables required bysubsection (3) are provided to the highest ranking employee at the facility mentioned insubsection (1)
(6) No later than March 31 of each year for the previous year the highest ranking employeeat the facility mentioned in subsection (1) shall certify in writing that the tables mentioned insubsection (3) have been received
(7) A person who discharges or causes of permits the discharge of a contaminant describedin subsection (1) shall on request submit a copy of the tables mentioned in clausesubsection (3) to the Director or to a provincial officer as soon as practicable
Ontario Ministry of the Environment and Climate Change 83
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Records 10 (1) A person who discharges or causes or permits the discharge of a contaminant
mentioned in this industry standard shall retain a record required by this industry standard atthe facility for at least five years and make it available to a provincial officer or Director uponrequest as soon as practicable
(2) Despite subsection (1) installation records and equipment specifications must beretained for the life of all equipment installed in relation to a requirement of this industrystandard including thermocouples pollution control equipment and other instrumentation
Table 3-1 Veneer Plywood and Engineered Wood Products (Dryer Exhaust)
Item Column 1 OperatingParameter
Column 2 Range ofValues1
Column 3
Range of Values2
Column 4
Monitoring Frequency
1 Dryer Exhaust Diversion3
At least 10 over a 24-hour block average
At least 15 over a 24-hour blockaverage
Diverted Volumetric Flow Rate At least every 15 minutes 4
Total Hourly Volumetric Exhaust Flow Rate at Maximum Dryer Capacity At least annually5
1Column 2 does not apply to an individual source of contaminant listed in subsection 4(1) if the person who discharges or causes or permits the discharge of the contaminant demonstrates that the combined average percentage diversion of dryer exhaust for all sources of contaminant for which parameters are identified under clause (a) of subsection 4(2) is at least 10
2 Column 3 does not apply to an individual source of contaminant listed in subsection 4(1) if the person who discharges or causes or permits the discharge of the contaminant demonstrates that the combined average percentage diversion of dryer exhaust for all sources of contaminant for which parameters are identified under clause (a) of subsection 4(2) is at least 15
3 Dryer Exhaust Diversion must be determined in accordance with Footnote 6 or 7 4 Diverted Volumetric Flow Rate may be determined using the position of the damper relative the position of the damper at full flow of the over-fire air fan (ie 100 open damper position) For example if the damper were 50 open the diverted volumetric flow rate would be determined by multiplying the maximum flow rate of the over-fire air fan by 50
5 Column 4 does not apply to a source of contaminant listed in subsection 4(1) in respect of Total Volumetric Exhaust Flow Rate if the flow rate recorded is the flow rate based on original manufacturerrsquos specifications
6 Determination of Average Dryer Exhaust Diversion for an Individual Dryer over a 24-Hour Block When determining the percentage Dryer Exhaust Diversion for an Individual Dryer the following steps shall be followed
1 measure the diverted volumetric low rate for the dryer at least every 15 minutes for a one hourperiod
2 determine the average hourly diverted volumetric flow rate for the dryer3 determine the total hourly volumetric exhaust flow rate at maximum dryer capacity4 divide the value in step 2 by the value in step 35 repeat steps 1 through 4 for every hour that the dryer operated with furnish during a period of 24
consecutive hours6 add up the values determined under step 5 and divide by the number of hours that the dryer operated
with furnish during the period
84Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
7 Determination of combined average percentage diversion of Dryer Exhaust Diversion over a 24-Hour Block When determining the combined percentage Dryer Exhaust Diversion for all dryers to which this parameter applies the following steps shall be followed
1 For each dryer to which the dryer exhaust diversion parameter appliesa measure the diverted volumetric low rate for the dryer at least every 15 minutes for a one hour
period b determine the average hourly diverted volumetric flow rate for the dryerc determine the total hourly volumetric exhaust flow rate at maximum dryer capacity
2 For each dryer to which the dryer exhaust diversion parameter applies sum each value determinedunder step 1b for every hour that the dryer operated during a period of 24 consecutive hours anddivide by the total number of hours that the dryer operated during the period
3 For each dryer to which the dryer exhaust diversion parameter applies sum each value determinedunder step 1c for every hour that the dryer operated with furnish during a period of 24 consecutivehours divide by the total number of hours that the dryer operated with furnish during the period
4 Sum the values determined in step 3 for all dryers to which the dryer exhaust diversion parameterapplies
5 Sum the values determined in step 4 for all dryers to which the dryer exhaust diversion parameterapplies
6 Divide the value determined in step 5 by step 6
Table 3-2 Veneer Plywood and Engineered Wood Products (Inlet Temperature andMoisture Content)
Item Column 1
Operating Parameter
Column 2
Range of Values
Column 3
Range of Values
Column 4
Monitoring Frequency
1 Inlet temperature Less than 316oC (600F) over a 24-hour block average
Less than 232oC (450F) over a 24-hour block average
At least every 15 minutes
2 Inlet moisture content of furnish
Less than 30 by weight on a dry basis over a 24shyhour block average
Less than 30 by weight on a dry basis over a 24shyhour block average
At least every 15 minutes
85Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Table 3-3 Inspection and Calibration ndash Veneer Plywood and Engineered Wood Products
Item Column 1
Device
Column 2
General Requirements
Column 3
InspectionRequirements
Column 4
InspectionFrequency
Column 5
Calibration
Column 6
Calibration Frequency
1 Inlet Temperature
1 Inlet Dryertemperature sensormust be in aposition thatprovides arepresentativetemperature
Inspection of all temperature monitor components and all electrical connections for continuity oxidation and galvanic corrosion
Quarterly 1 Calibration of inlettemperature monitors withan accurate within 075 ofsensor range or +- 25oC
2 Temperature sensorvalidation of the inlettemperature is required
1 Asrecommendedby themanufacturer
2 If 1 is notapplicable atleast two
2 If a chartrecorder is usedthen the minordivisions must benot more than10oC
when sensor exceeds themanufacturerrsquos maximumoperating temperaturerange
times peryear or
3 If 1 and 2are notapplicablewhentechnicallyfeasible
2 Inlet Moisture
Inlet moisture monitor in a position that provides a representative measure of furnish moisture
Inspection of all moisture meter components and all electrical connections for continuity oxidation and galvanic corrosion
Quarterly Calibration of inlet moisture meters accurate within 1 (dry basis) moisture of 25shy35 moisture content range
1 Asrecommendedby themanufacturer
2 If 1 is notapplicable at least twotimes peryear or
3 If 1 and 2are notapplicablewhentechnicallyfeasible
86Ontario Ministry of the Environment and Climate Change
Tracking Date Publishing Minister
Version 20
Forest Products - Industry Standard
Created March 5 2015 Bradley
Version 10
Forest Products - Industry Standard
Created December 4 2009 Gerretsen
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Table 3-4 Operating Parameters ndash Sawmills
Item Column 1
Operating Parameter
Column 2
Monitoring Frequency
1 Wood moisture content Once per load
Table 3-5 Inspection and Calibration ndash Sawmills
Item Column 1 Device
Column 2 Inspection
Requirements
Column 3 InspectionFrequency
Column 4 Calibration
Column 5 Calibration Frequency
1 Moisture meter Consistent with manufacturerrsquos recommendations
Quarterly Consistent with manufacturerrsquos recommendations
1 As recommendedby the manufacturer
2 If 1 is notapplicable at leasttwo times per yearor
3 If 1 and 2 are notapplicable whentechnically feasible
Record of Publications for Forest Products - Industry Standard
87Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
CHAPTER 4 - PULP AND PAPER ndash INDUSTRY STANDARD
Version 10 Created March 5 2014
Preamble
bull This technical standard is an industry standard as defined in section 1 of O Reg41905
bull With respect to facilities this standard applies to every facility that is part of a classidentified by NAICS code 3221 (Pulp Paper and Paperboard Mills) but does not apply topulp and paper facilities using an ldquoacid-sulphite processrdquo
bull With respect to contaminants this standard applies to contaminants listed in Appendix4 - A
bull Each source of contaminant associated with NAICS code 3221 that discharges acontaminant mentioned in the above bullet has been considered in development of thisindustry standard As such a person that meets the criteria set out in subsection 42 (1)or subsection 44 (1) of O Reg 41905 is in general exempt from Part II of theRegulation in respect of the facility and contaminant(s) for which it is registered In otherwords there is no need to model in a facilityrsquos Emission Summary and DispersionModelling report discharges of a registered contaminant from any source ofcontaminant associated with NAICS code 3221 (For more information please see theIntroduction to the Technical Standards Publication)
bull In accordance with subsection 38 (3) of O Reg 41905 compliance with this industrystandard in accordance with subsection 42 (5) or subsection 44 (3) may reduce theregulatory burden applicable to facilities in this class
bull This standard contains requirements that relate to the following sources of contaminant
bull digester systemsbull evaporator systemsbull turpentine recovery systemsbull steam stripper systemsbull systems that collect non-condensable gasbull wastewater treatment systemsbull unbleached kraft linerboard paper machinesbull tall oil reactorsbull weak black liquor storage tank ventsbull black liquor salt cake mix tank ventsbull brownstock washersbull oxygen delignification systemsbull bleach plant ventsbull thermo-mechanical pulping ventsbull large wood-fired combustorsbull slakerbull smelt dissolving tankbull recovery boiler
Ontario Ministry of the Environment and Climate Change 88
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
bull lime kilnbull thermal oxidizerbull bleach plant chlorinated-stage washer hoodbull bleach plant chlorine dioxide generatorbull bleach plant chlorine dioxide storage vents
bull For this industry standard with respect to total reduced sulphur (TRS) compounds thepublication of this industry standard indicates that the following criteria of paragraph 3 ofsubsection 38 (1) of O Reg 41905 are met
(a) with respect to at least two facilities located in Ontario to which this standard appliesit is not economically feasible to comply with section 20 of O Reg 41905
(b) compliance in accordance with subsection 42 (5) of O Reg 41905 with thisstandard
(i) is technically and economically feasible with respect to at least one facilitylocated in Ontario to which this industry standard applies and
(ii) will permit efforts that would otherwise be made to comply with section 19 or20 of O Reg 41905 to be put to better use to protect the naturalenvironment having regard to clause (a) and
(iii) including this industry standard in the ldquoTechnical Standards to Manage AirPollutionrdquo is more efficient than having the Director consider separaterequests under section 32 of O Reg 41905 to set site-specific standards forthe contaminant that would otherwise apply to facilities in the class
Ontario Ministry of the Environment and Climate Change 89
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
CONTENTSPART I ndash GENERAL 1 Definitions2 Facility Expansion3 Application
PART II ndash PERFORMANCE 4 Performance Limit ndash TRS Compounds in Wastewater Treatment System5 Performance Limit ndash Community Ambient TRS Monitor6 Performance Limit ndash Wastewater TRS Monitor7 Large Wood-fired Combustor - Carbon Monoxide Concentration Limit8 Large Wood-fired Combustor - Nitrogen Oxides Concentration Limit9 Large Wood-fired Combustor ndash Suspended Particulate Matter Stack-Test Concentration Limit10 Large Wood-fired Combustor ndash Dioxins etc Stack-Test Concentration Limit11 Large Wood-fired Combustor ndash Limit Exemptions12 Notification ndash Exceedence of Limit13 Implementation of Procedures14 Corrective Action Procedures15 Order for Specified Corrective Action Procedures
PART III ndash OPERATIONAL PRACTICES 16 Steam Stripping of Process Condensate Streams17 Steam Stripper System By-Pass ndash Notification18 Incineration ndash Semi-Chemical Process19 Failure of Incineration Device Semi-chemical Process - Notification20 Incineration of NCGs ndash Kraft Process21 Failure of a Back-up Incineration Device (Concentrated NCG) Kraft Process ndash Notification22 Failure of an Incineration Device (Dilute NCG) Kraft Process - Notification23 Procedures to Minimize Acrolein24 Large Wood-fired Combustors - Combustion Air Requirements25 Large Wood-fired Combustors - Air Pollution Control Devices26 Large Wood-fired Combustors - Fuel Management27 New Large Wood-Fired Combustors - Residence Time amp Temperature28 Thermal Oxidizers ndash Residence Time29 Brownstock Shower Water30 Bleaching of Pulp31 Heat Recovery32 New Pulp and Paper Facility that Uses the Kraft Process - Wastewater Treatment System33 Air Pollution Control ndash Requirement to Continue34 Specified Air Pollution Control Devices35 Facility ndash Parameter Summary Table36 Facility ndash Deviation from Operational Parameters37 Inspection and Maintenance38 Process Loss ndash Best Management Practices39 Bi-Annual Adjustment of Large Wood-fired Combustor Operation
PART IV ndash OPERATIONAL OPTIMIZATION ASSESSMENTS 40 Treatment of Process Condensate Streams ndash Assessment Report41 Treatment of Process Condensate Streams ndash Optimization Report42 Steam Stripping Assessment and Optimization Update43 Process Loss Assessment Report44 Process Loss Minimization Report45 Process Loss Assessment and Minimization Update46 Wastewater Treatment System ndash Assessment Plan and Report47 Wastewater Treatment System ndash Optimization Report amp Implementation
Ontario Ministry of the Environment and Climate Change 90
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
48 Wastewater Treatment System Assessment and Optimization Update
PART V ndash MONITORING 49 In-Facility Monitoring50 Ambient Monitoring51 Baseline TRS Monitoring Data ndash Wastewater52 Statistical Analysis of TRS Concentration from Wastewater Monitor53 Large Wood-fired Combustor - Continuous Monitoring ndash Nitrogen Oxides54 Large Wood-fired Combustor - Continuous Monitoring ndash Carbon Monoxide Oxygen and
Temperature55 Large Wood-fired Combustor - In-Stack Concentration Testing ndash After Commissioning Period56 Large Wood-fired Combustor - Periodic In-Stack Concentration Testing57 Large Wood-fired Combustor - In-Stack Testing Approval
PART VI ndash RECORDS AND REPORTING 58 Complaint Procedure59 Removal Efficiency Report ndash Steam Stripper60 Removal Efficiency Report ndash Chlorine Dioxide Scrubber61 Annual Summaries62 Records
APPENDIX 4-A All Contaminants
APPENDIX 4-B Products of Combustion ndash Large Wood-fired Combustors
APPENDIX 4-C Products of Combustion ndash Large Wood-fired Combustors Burning Some Municipal Waste
APPENDIX 4-D Volatile Organic Compounds
Ontario Ministry of the Environment and Climate Change 91
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
PART I ndash GENERAL
Definitions 1 (1) For the purposes of this pulp and paper industry standard
ldquoacid-sulphite processrdquo means a chemical pulping process that uses a mixture of sulphurousacid and bisulphites as the cooking liquid this process may be in use at a facility in a classidentified by the following NAICS codes 322112 322121 322122 or 322130
ldquoactivated sludge systemrdquo means a system for the secondary treatment of wastewater in whichan aerated biological process that uses flocculated micro-organisms occurs and in which aportion of the resulting biomass settles out in a downstream sedimentation tank a portion ofthe biomass is recycled to an aeration tank and a portion of the biomass is removed asexcess sludge
ldquoActrdquo means the Environmental Protection Act RSO 1990 c E19 ldquoadsorption systemrdquo means a system that uses the technology of adsorbing a pollutant on the
surface of a granule bead or crystal of adsorbent material ldquoADUPrdquo means air-dried unbleached pulp ldquoaerated stabilization basin systemrdquo means a system for the secondary treatment of wastewater
that meets the following criteria 1 A system that uses a series of aerated stabilization basins in which an aerated biological
process occurs2 The process mentioned in paragraph 1 produces biomass that settles to the bottom of
each basin3 The biomass mentioned in paragraph 2 is stabilized by microbial decomposition and is not
recycledldquoaerated stabilization basin cellrdquo means (a) if an area of an individual aerated stabilization basin is distinguishable from other areas
within that basin due to physical separation of the area or a unique characteristic of thewastewater in the area that area of the basin or
(b) if there are no distinguishable areas within an aerated stabilization basin the basin itselfldquoair pollution control devicerdquo means a device that removes contaminants from air and includes
electrostatic precipitators scrubbers baghouses cyclones adsorption systems thermal oxidizers biofilters and spray towers
ldquoaverage daily production raterdquo means the amount in tonnes of ADUP that the facility produceson average in one day and is calculated by summing the amount of ADUP that each digesterat the facility typically produces in a 24-hour period
ldquobaghouserdquo means a device that uses fabric bags or cartridge filters to remove particulate froma gaseous stream prior to its discharge of the gaseous stream into the air
ldquoblack liquorrdquo means the aqueous solution containing lignin residues and other compoundswhich is separated from cellulose fibres during the process of digesting wood at a pulp andpaper facility that uses the kraft process
ldquoBOD5rdquo means biochemical oxygen demand a measure of the dissolved oxygen used by microshyorganisms to decompose organic matter in water at 20degC over the course of five consecutivedays
ldquoCAS Nordquo has the same meaning as in subsection 1 (1) of O Reg 41905
Ontario Ministry of the Environment and Climate Change 92
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
ldquoclosed systemrdquo means a system of piping ductwork and connections that transmits a gasvapour or liquid from a point of generation to another location without discharging the gasvapour or liquid into the air
ldquocombustorrdquo means a device in which combustible material is oxidized resulting in release ofheat and products of combustion
ldquocommissioning periodrdquo means the 90-day period following the first start-up of a new or significantly modified large wood-fired combustor
ldquoconcentrated NCGrdquo means subject to subsection 20 (6) a non-condensable gas generated byan evaporator system digester system turpentine recovery system or steam stripper systemat a pulp and paper facility that uses the kraft process
ldquodaily production raterdquo means the amount in tonnes of ADUP produced by the facility in oneday and is calculated by summing the amount of ADUP that each digester at the facilityproduces on that day
ldquodaily production rate capacityrdquo means the amount in tonnes of ADUP that the facility iscapable of producing in one day and is calculated by summing the amount of ADUP that eachdigester at the facility is designed to produce in a 24-hour period
ldquodefectrdquo means a failure in a closed system that could result in the emission of gas vapour orliquid into the air and includes (a) cracks holes or gaps in the ductwork or piping(b) loose connections and(c) broken or missing caps on closure devices
ldquodigesterrdquo means a pressurized tank that is used to cook and chemically treat wood chips eitherby batch or continuous process
ldquodigester systemrdquo means a system consisting of all associated digesters and equipmentsupporting the operation of the digester including flash tanks blow tanks chip steamersblow heat accumulators and relief gas condensers
ldquodilute NCGrdquo means a non-condensable gas that is not a concentrated NCG ldquodioxins furans and dioxin-like PCBsrdquo has the same meaning as in subsection 1 (1) of O Reg
41905 and is calculated in accordance with subsection 1 (202) of O Reg 41905 ldquodistrict managerrdquo means in respect of a facility the district manager of the local Ministry office
located closest to the facility ldquodirect contact dryerrdquo means a large wood-fired combustor that is used to dry wood material in a
manner such that the flue gas from the combustor comes into direct contact with the woodmaterial that is to be dried
ldquoECArdquo means environmental compliance approval as defined in subsection 1 (1) of the Act ldquoelectrostatic precipitatorrdquo means a device which removes dust or other finely divided particles
from a gas by charging the particles inductively with an electric field then attracting them tohighly charged collector plates
ldquoevaporatorrdquo means a device used to increase the solids content of the spent cooking liquorproduced by the pulp washing system
ldquoevaporator systemrdquo means a system consisting of all associated evaporators and equipment supporting the operation of the evaporator including pre-evaporators multiple effects evaporators concentrators hotwells and surface condensers
ldquoexisting large wood-fired combustorrdquo means a large wood-fired combustor that has not undergone a significant modification and (a) construction of the large wood-fired combustor was completed or began on or before
March 31 2014 or(b) an application was made on or before March 31 2014 for an ECA in respect of the large
wood-fired combustor
Ontario Ministry of the Environment and Climate Change 93
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
ldquoexisting pulp and paper facilityrdquo means a pulp and paper facility (a) the construction of which was completed or began on or before March 31 2014 or(b) in respect of which an application was made on or before March 31 2014 for an ECA
ldquoflue gasrdquo means a gas that is generated by a combustion process ldquofurnacerdquo means a part of a combustor where combustion takes place ldquoheat input capacityrdquo means the ability of a large wood-fired combustor to combust a maximum
amount of fuel based on the physical design of the large wood-fired combustor and is calculated by multiplying the flow rate of the fuel by the higher heating value of the fuel
ldquohigher heating valuerdquo means the amount of heat released during the complete combustion of aunit quantity of fuel In contrast the net or lower heating value is obtained by subtracting thelatent heat of vapourization of the water vapour formed by the combustion
ldquohogged wood fuelrdquo means an unprocessed mix of coarse chips of bark and wood fibre generated by grinding or chipping action
ldquoindustry standardrdquo has the same meaning as in subsection 1 (1) of O Reg 41905 ldquokraft processrdquo means a chemical pulping process that uses a mixture of sodium hydroxide and
sodium sulphide as the cooking liquor this process may be in use at a facility in a classidentified by the following NAICS codes 322112 322121 322122 or 322130
ldquolarge wood-fired combustorrdquo means subject to subsection 3 (2) a combustor that has a heatinput capacity of at least three megawatts and that is designed to burn wood fuel
ldquolime kilnrdquo means a combustion device used to calcine lime mud into calcium oxide ldquolime mudrdquo means mud that consists primarily of calcium carbonate ldquomgRm3rdquo means milligrams per cubic metre at reference conditions ldquoMinistry means the Ministry of the Government of Ontario responsible for the Act and its
regulations and includes all officials employees or other persons acting on its behalf ldquomunicipal wasterdquo has the same meaning as in Ontario Regulation 347 RRO 1990 ldquoMWrdquo means megawatt and is equal to 3600 megajoules per hour ldquoNAICSrdquo has the same meaning as in subsection 1 (1) of O Reg 41905 ldquoNCGrdquo means a non-condensable gas which is a gas that is not easily condensed by cooling ldquonew large wood-fired combustorrdquo means a large wood-fired combustor the construction of
which began after March 31 2014 and no application was made on or before that day foran ECA in respect of the large wood-fired combustor
ldquonew pulp and paper facilityrdquo means a pulp and paper facility the construction of which beganafter March 31 2014 and no application was made on or before that day for an ECA inrespect of the facility
ldquoO Reg 41905rdquo means Ontario Regulation 41905 (Air Pollution ndash Local Air Quality) made under the Act
ldquopower boilerrdquo means a device that has the primary purpose of recovering thermal energy in theform of steam through combustion of wood and other fuels
ldquoppmrdquo means parts per million and is a measure of concentration ldquoprimary treatmentrdquo means a process that
(a) is located upstream of the secondary treatment process in a wastewater treatmentsystem and
(b) uses a basin or tank to settle out suspended solids in wastewater under the influence ofgravity
ldquoprocess condensate streamrdquo means a condensate stream that has come into contact with totalreduced sulphur (TRS) compounds or turpentine and includes condensate streams from (a) evaporator systems and
Ontario Ministry of the Environment and Climate Change 94
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(b) any system that collects NCGsldquoprocess lossrdquo means the loss of a material that would otherwise be used in a process at a pulp
and paper facility and includes (a) black liquor turpentine and tall oil soap that enters the wastewater treatment system and(b) a process condensate stream that is required by this industry standard to be treated for
example transmitted to a steam stripper but is instead enters the wastewater treatmentsystem
ldquoprovincial officerrdquo has the same meaning as in the Act ldquopulp and paper facilityrdquo means a facility at which pulp paper or paperboard is produced and
which is part of a class identified by NAICS code 3221 (Pulp Paper and Paperboard Mills)but for the purposes of this industry standard does not include a facility that uses an acidshysulphite process
ldquorecordrdquo includes a written procedure a measurement result a written notification a table areport a document information provided to the highest ranking employee for review a writtenpractice anything required by this industry standard to be recorded and an update to any ofthe preceding
ldquorecovery boilerrdquo means a device used at a pulp and paper facility that uses the kraft processthat has the primary purpose of recovering chemicals through burning black liquor
ldquoreference conditionsrdquo mean conditions at which the temperature is 25 degrees Celsius and thepressure is 1013 kilopascals
ldquorefinerrdquo means a device which mechanically separates wood chip fibre ldquoregistered contaminantrdquo means a contaminant that is discharged into the air from a facility if a
person is registered in respect of this industry standard the facility and the contaminant ldquoregistrationrdquo means registration on the Ministryrsquos Technical Standards Registry ndash Air Pollution
in respect of this industry standard ldquoresidence timerdquo means the average amount of time that a gas spends in a furnace and is
calculated by dividing the volume of the furnace by the volumetric flow rate of the gas throughthe furnace
ldquosecondary treatmentrdquo means a process that (a) occurs in a wastewater treatment system downstream of the primary treatment processand(b) uses micro-organisms and sedimentation to remove dissolved and suspended organicmatter from wastewater under managed conditions
ldquosemi-chemical processrdquo means a process that makes pulp by using chemical pre-treatments tosoften the wood chips and mechanically separating the fibres in an atmospheric or pressurized refiner this process may be in use at a facility in a class identified by thefollowing NAICS codes 322111 322121 322122 or 322130
ldquoshut-downrdquo means an operating condition during which the operation of a source of contaminant is decreased from normal operating conditions to an inoperative state
ldquosignificant modificationrdquo means a modification that (a) increased the intensity measured as mass of emissions per unit heat input capacity of
emissions of suspended particulate matter or benzo-a-pyrene(b) increased the heat input capacity of the large wood-fired combustor(c) resulted in the large wood-fired combustor having a heat input capacity of greater than 20
MW and(d) began after July 1 2015 and no application was made on or before that date with respect
to the modificationldquosignificantly modified large wood-fired combustorrdquo means a large wood-fired combustor that
has undergone a significant modification
Ontario Ministry of the Environment and Climate Change 95
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
ldquostart-uprdquo means an operating condition during which the operation of a source of contaminantis increased from an inoperative state to normal operating conditions
ldquosteam stripperrdquo means a device that uses steam to remove contaminants from incoming streams of liquid
ldquosteam stripper systemrdquo means a system that consists of all associated steam strippers andequipment supporting the operation of the steam stripper including steam stripper feed tankscondensers heat exchangers and stripped condensate storage tanks
ldquosuspended particulate matterrdquo means particulate matter that has an aerodynamic diameter ofless than 44 microns
ldquotechnical standardrdquo has the same meaning as in subsection 1 (1) of O Reg 41905 ldquothermal oxidizerrdquo means a device in which a combustible waste gas passes over or around a
burner flame into a chamber where oxidation of the waste gas is completed ldquothermo-mechanical processrdquo means a process that makes pulp by heating wood chips with
steam and mechanically separating the fibres in a pressurized refiner this process may be inuse at a facility in a class identified by the following NAICS codes 322111 322121 322122or 322130
ldquototal reduced sulphur (TRS) compoundsrdquo has the same meaning as in subsection 1 (1) of OReg 41905
ldquotreatmentrdquo with respect to a process condensate stream means a process by which VOCs ortotal reduced sulphur (TRS) compounds or both are removed from a process condensatestream
ldquoturpentine recovery systemrdquo means a system that includes all equipment associated with recovering turpentine from the gas produced by the digesting process in a digester systemincluding decanters condensers and storage tanks
ldquoVOCsrdquo means volatile organic compounds which are organic chemical compounds excludingcarbon monoxide carbon dioxide carbonic acid metallic carbides or carbonates and ammonium carbonate whose composition makes it possible for them to evaporate undernormal atmospheric conditions of temperature and pressure and includes the contaminantsthat are listed in Appendix 4-D
ldquowastewater treatment systemrdquo means a system at a pulp and paper facility that is a part of a sewage works as defined in the Ontario Water Resources Act RSO 1990 c O40 and includes all parts of the system upstream of the point of discharge of the sewage from thesewage works to the natural environment
weekday means any Monday Tuesday Wednesday Thursday or Friday that is not a holidayas defined in the Legislation Act 2006 SO 2006 c 21 Schedule F
ldquowet scrubberrdquo means a device that is used to separate and collect gaseous liquid and particulate pollutants from a gas stream into a water-based solution
ldquowoodchiprdquo means a piece of wood of a defined size cut or chipped from a larger piece of wood
ldquowood fuelrdquo means fuel comprised of one or more of the following materials hogged wood fuelwood chips wood pellets bark sawdust woodwaste cellulosic plant material paper andpaper sludge
ldquowood pelletrdquo means a pellet made by compacting sawdust woody cellulosic plant material orother woodwaste
ldquowoodwasterdquo has the same meaning as in Ontario Regulation 347 RRO 1990 (2) In this industry standard a reference to the Director means(a) the Director appointed under section 5 of the Act in respect of the section of this industry
standard in which the reference appears(b) if no Director described in clause (a) has been appointed in respect of subsection 49 (9)
53 (1) 54 (1) 57 (1) or 57 (3) of this industry standard any Director appointed undersection 5 of the Act in respect of paragraph 2 of subsection 11 (1) of O Reg 41905 or
Ontario Ministry of the Environment and Climate Change 96
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(c) if no Director described in clause (a) has been appointed in respect of a provision otherthan a provision mentioned in clause (b) any Director appointed under section 5 of theAct in respect of section 271 or paragraph 3 of subsection 11 (1) of O Reg 41905
(3) In this industry standard reference to a concentration as it relates to requirements forlarge wood-fired combustors is a reference to a concentration by volume on a dry basiscorrected to 11 per cent oxygen-dry in the flue gas(4) In this industry standard reference to a percentage of oxygen is a reference topercentage oxygen by volume on a dry basis(5) If this industry standard requires a measurement of total reduced sulphur (TRS)compounds in process condensate or wastewater the measurement shall be performed byone of the following methods1 The method entitled ldquoMethod RSC-0202 Reduced Sulfur Compounds by Direct Injection
GCPFPDrdquo published by the National Council for Air and Stream Improvement Inc inMarch 2007 as amended from time to time
2 If the concentration is being measured for the purpose of sections 40 or 46 the methodentitled ldquoA Method for the Analysis of Total Reduced Sulphur (TRS) Compounds in KraftMill Aqueous Process Streams Pulp and Paper Report PPR 1300rdquo published by Papricanin July 1997 as amended from time to time
3 A method of measurement that in the opinion of the Director would measure theconcentration of total reduced sulphur (TRS) compounds at least as accurately as amethod mentioned in paragraph 1 or 2
(6) If a provision of this industry standard specifies a period of time over which a series ofmeasurements of total reduced sulphur (TRS) compounds are required to be taken onemethod mentioned in subsection (5) shall be used for all measurements in the series over thespecified period of time(7) For further certainty reference to a concentration of 27 ppb of total reduced sulphur(TRS) compounds in section 4 5 and 61 may be expressed as 27 ppb or 40 microgm3
Facility Expansion 2 (1) No later than the date of registration the owner and operator of a pulp and paper
facility that uses the kraft process shall ensure that the total amount of ADUP in tonnes thatthe facility is capable of producing in a one-year period calculated by summing the amount ofADUP that each digester at the facility is designed to produce is submitted in writing to theDirector
(2) If the facility mentioned in subsection (1) intends to increase the capacity of the facility toproduce ADUP to a value that exceeds the value submitted under subsection (1) the ownerand operator of the facility shall ensure that the Director is notified in writing of this intention nolater than one year prior to the date when the increase is anticipated to be implemented
(3) The notice required to be given under subsection (2) shall include(a) an indication of the amount of ADUP that the facility will be capable of producing when the
increase is implemented(b) an explanation of the anticipated effect of the increase on the discharge of total reduced
sulphur (TRS) compounds to the air from the facility and(c) a summary of actions that have been taken or that will be taken to inform the public of
the anticipated effect mentioned in clause (b)(4) The amount of ADUP indicated in clause (a) of subsection (3) shall from the date the
increase is implemented be considered the amount for the purposes of subsection (1)(5) If the Director is of the opinion that the actions summarized for the purpose of clause (c)
of subsection (3) are inadequate to inform the public of the impact of the increase on discharges of contaminants to the air from the facility the Director may give a person who isrequired to give notice under subsection (2) a notice specifying actions to be taken to explainthe impact of the intended increase in capacity of the facility to produce ADUP on the dischargeof contaminants to the air from the facility
Ontario Ministry of the Environment and Climate Change 97
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(6) Before the Director gives a person a notice under subsection (5) the Director shall givethe person a draft of the notice and an opportunity to make written submissions to the Directorduring the period that ends 30 days after the draft is given
Application 3 (1) This industry standard applies in accordance with subsections (2) to (11) to a person
who is registered on the Ministryrsquos Technical Standards Registry ndash Air Pollution in respect of (a) this industry standard(b) a pulp and paper facility and(c) one or more of the contaminants listed in Appendix 4-A(2) A person mentioned in subsection (1) may not register in respect of a pulp and paper
facility and a contaminant listed in Appendix 4-C if either of the following criteria is met 1 The facility has a large wood-fired combustor that burns municipal waste that does not
contain wood2 The facility has a large wood-fired combustor that burns municipal waste other than
woodwaste and such waste comprises more than 75 per cent by weight of the fuel beingburned
(3) If the person mentioned in subsection (1) is registered with respect to a pulp and paperfacility and one or more of the contaminants listed in Appendix 4-A the following sections applyin respect of the person 1 3 28 33 35 36 37 49 58 61 and 62
(4) If the facility mentioned in subsection (3) has a large wood-fired combustor that does notburn municipal waste and the person mentioned in subsection (1) is registered with respect tothat facility and one or more of the contaminants listed in Appendix 4-B the following sections apply with respect to the person 7 8 9 11 12 13 14 as it relates to carbonmonoxide 15 24 25 26 27 39 53 54 section 55 with respect to paragraphs 1 and 2 ofsubsection 55 (1) 56 and 57 in addition to the sections that apply to the person under subsection (3)
(5) If the facility mentioned in subsection (3) has a large wood-fired combustor that may burnmunicipal waste and the person mentioned in subsection (1) is registered with respect to thatfacility and one or more of the contaminants listed in Appendix 4-B or 4-C the followingsections apply with respect to the person 7 8 9 10 11 12 13 14 as it relates to carbonmonoxide 15 24 25 26 27 39 53-57 in addition to the sections that apply to the personunder subsection (3)
(6) Subject to subsection (7) if a facility mentioned in subsection (3) (4) or (5) uses the kraftprocess and the person mentioned in subsection (1) is registered with respect to that facilityand one or more contaminant set out in Column 1 of Table 4-3 the sections set out in Column 2 of Table 4-3 opposite the contaminant apply with respect to the person in addition to the sections that apply to the person under subsection (3) (4) or (5) as applicable
(7) If the facility mentioned in subsection (6) does not have any aerated stabilization basinsthe following sections set out in Item 1 of Table 4-3 do not apply in respect of the facility 4 6paragraphs 1 to 4 of subsection 14 (1) 41 (2) 46 47 48 clause (b) of subsection 50 (1) 51and 52
(8) If a facility mentioned in subsection (3) (4) or (5) uses the semi-chemical process and theperson mentioned in subsection (1) is registered with respect to that facility and one or morecontaminants listed in Appendix 4 - D sections 18 and 19 apply with respect to the personin addition to the sections that apply to the person under subsection (3) (4) or (5) as applicable
(9) If a facility mentioned in subsection (3) (4) or (5) uses the thermo-mechanical processthe following sections apply
1 If the person mentioned in subsection (1) is registered with respect to that facility and oneor more contaminants listed in Appendix 4-D section 31 applies with respect to theperson in addition to the sections that apply to the person under subsection (3) (4) or(5) as applicable
2 If the person mentioned in subsection (1) is registered with respect to that facility andacrolein section 23 applies with respect to the person in addition to the sections thatapply to the person under subsection (3) (4) or (5) as applicable
(10) If a facility mentioned in subsection (3) (4) or (5) has an unbleached kraft linerboardpaper machine and is registered with respect to that facility and acrolein section 23 applies with
Ontario Ministry of the Environment and Climate Change 98
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
respect to the person in addition to the sections that apply to the person under subsection (3)(4) or (5) as applicable
(11) A person mentioned in subsection (1) is required to comply with the sections of thisindustry standard that apply to the person in accordance with subsections (3) to (10) on orbefore the date the person registers on the Ministryrsquos Technical Standards Registry ndash Air Pollution unless a different date is specified in this industry standard
Table 4-3 Application
Item Column 1 Contaminant
Column 2 Sections
1 Total reduced sulphur (TRS) compounds
2 4 5 6 12 13
14 as it relates to total reduced sulphur (TRS) compounds
15 16 17 20 21 22 29
34 with respect to Items 1 and 2 of Table 4-34
38 40 41 42 43 44 45 46 47 48 50 51 52 59
2
Chlorine
Chlorine Dioxide
Chloroform
2
34 with respect to Items 4 5 and 6 of Table 4-34
60
3 Any contaminant listed in Appendix 4-D 2 20 21 59
4 Benzo(a)pyrene 2
34 with respect to Items 2 7 and 8 of Table 4-34
5 Suspended particulate matter
2
34 with respect to Items 2 37 and 8 of Table 4-34
6 Acrolein 2 23
7 Any contaminant listed in Appendix 4-A 30 32
PART II ndash PERFORMANCE
Performance Limit ndash TRS Compounds in Wastewater Treatment System 4 (1) Subject to subsections (2) and (3) no person shall cause or permit the daily loading of
total reduced sulphur (TRS) compounds in the water entering the wastewater treatment systemat a pulp and paper facility that uses the kraft process to exceed 0335 kilograms of totalreduced sulphur (TRS) compounds per tonne of ADUP
99Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(2) Subsection (1) does not apply to an existing pulp and paper facility during a period of timebetween
(a) March 31 2014 and July 1 2015(b) July 1 2015 and June 30 2016 if during the period the daily loading of total reduced
sulphur (TRS) compounds in the water entering the wastewater treatment system doesnot exceed 098 kilograms of total reduced sulphur (TRS) compounds per tonne of ADUPor
(c) July 1 2016 and June 30 2020 if during the period the daily loading of total reducedsulphur (TRS) compounds in the water entering the wastewater treatment system doesnot exceed 0658 kilograms of total reduced sulphur (TRS) compounds per tonne ofADUP
(3) Subsection (1) does not apply if during the 14-day period following the date on which acontravention of subsection (1) occurred no wastewater ambient monitor identified as adequateunder section 50 measures a concentration of total reduced sulphur (TRS) compounds thatexceeds 27 ppb over a 10-minute averaging period
Performance Limit ndash Community Ambient TRS Monitor 5 (1) Subject to subsection (2) no person shall discharge or cause or permit the discharge
of total reduced sulphur (TRS) compounds into the air from a pulp and paper facility that usesthe kraft process if the discharge results in the concentration of total reduced sulphur (TRS)compounds at a community ambient monitor identified as adequate under section 50 exceeding27 ppb over a 10-minute averaging period more than two times in any six-month period
(2) Subsection (1) does not apply to an existing pulp and paper facility if the date is beforeJuly 1 2016 and the concentration of total reduced sulphur (TRS) compounds at the monitordescribed in subsection (1) does not exceed 27 ppb over a 30-minute averaging period morethan two times in any six-month period
Performance Limit ndash Wastewater TRS Monitor 6 (1) Subject to subsection (2) no person shall discharge or cause or permit the discharge
of total reduced sulphur (TRS) compounds into the air from a pulp and paper facility that usesthe kraft process if it is determined under section 52 that there has been a statistically significant increase in the concentration of total reduced sulphur (TRS) compounds at a wastewater ambient monitor identified as adequate under section 50
(2) Subsection (1) does not apply if written notice has been given by the Director undersubsection 52 (8)
Large Wood-fired Combustor - Carbon Monoxide Concentration Limit 7 (1) Subject to subsection (2) no person shall operate or cause or permit the operation of
an existing large wood-fired combustor at a pulp and paper facility if the concentration of carbonmonoxide in the flue gas of the combustor averaged over a ten-day period exceeds 500 ppm
(2) Subsection (1) does not apply during a period between(a) March 31 2014 and July 1 2016 or(b) July 1 2016 and June 30 2021 if during the period the concentration of carbon monoxide
in the flue gas of the combustor averaged over a ten-day period does not exceed 800ppm
(3) No person shall operate or cause or permit the operation of a new or significantlymodified large wood-fired combustor at a pulp and paper facility if the concentration of carbonmonoxide in the flue gas of the combustor averaged over a 24-hour period exceeds 400 ppm
Large Wood-fired Combustor - Nitrogen Oxides Concentration Limit 8 (1) Subject to subsection (2) no person shall operate or cause or permit the operation of
a new large wood-fired combustor at a pulp and paper facility if the concentration of nitrogenoxides in the flue gas of the combustor averaged over a 24-hour period exceeds 198 mgRm3
100Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(2) Subsection (1) does not apply if the large wood-fired combustor has a heat input capacityof less than 100 MW
Large Wood-fired Combustor ndash Suspended Particulate Matter Stack-Test ConcentrationLimit
9 (1) Subject to subsection (4) no person shall on or after July 1 2016 operate or causeor permit the operation of an existing large wood-fired combustor at a pulp and paper facility ifthe testing required by sections 55 or 56 results in a measurement of suspended particulatematter that exceeds 120 mgRm3
(2) Subject to subsections (3) and (4) no person shall operate or cause or permit theoperation of a new or significantly modified large wood-fired combustor at a pulp and paperfacility if the testing required by sections 55 or 56 results in a measurement of suspendedparticulate matter that exceeds 25 mgRm3
(3) If the large wood-fired combustor mentioned in subsection (2) is a new large wood-firedcombustor with a heat input capacity of 20 MW or less subsection (2) does not apply
(a) with respect to a measurement obtained under section 55 if the measurement ofsuspended particulate matter does not exceed 50 mgRm3 or
(b) with respect to a measurement obtained under section 56 if the measurement ofsuspended particulate matter does not exceed 50 mgRm3
(4) If the large wood-fired combustor mentioned in subsections (1) or (2) is a direct contactdryer subsections (1) and (2) do not apply
(a) with respect to a measurement obtained under section 55 if the measurement ofsuspended particulate matter does not exceed 250 mgRm3 or
(b) with respect to a measurement obtained under section 56 if the measurement ofsuspended particulate matter does not exceed 250 mgRm3
Large Wood-fired Combustor ndash Dioxins etc Stack-Test Concentration Limit 10 No person shall operate or cause or permit the operation of a large wood-fired
combustor at a pulp and paper facility if the testing required by sections 55 or 56 results in ameasurement of dioxins furans and dioxin-like PCBs that exceeds 80 pgRm3
Large Wood-fired Combustor ndash Limit Exemptions 11 Sections 7 to 10 do not apply during the following periods1 The commissioning period of the large wood-fired combustor2 The period during which the large wood-fired combustor is starting up or shutting down if
i the shut-down does not last for more than six hoursii the start-up does not last for more than 24 hoursiii the start-up or shut-down is conducted according to a written plan that minimizes
discharges into the air during the period of start-up or shut-downiv if opacity is required to be measured by Item 4 of Table 4 - 3 5 all
measurements required by Item 5 of Table 4-49 are recorded during the start-up orshut-down and
v all measurements required by section 53 and 54 are recorded during the start-up orshut-down
Notification ndash Exceedence of Limit 12 (1) The owner and operator of a pulp and paper facility shall ensure that as soon as
practicable a provincial officer is notified in writing of any contravention of sections 4 to 10
101Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(2) No later than 30 days after notice is required to be given under subsection (1) the ownerand operator shall ensure that the following information is submitted in writing to the districtmanager
1 The date and time of the contravention2 The details of the contravention including any measured or calculated values relating to
an exceedence of a limit3 An explanation of suspected cause of the contravention including the suspected cause of
each exceedence of a limit4 A description of any steps taken or that will be taken to prevent or minimize the risk of
future contraventions(3) Subject to subsection (4) if notice is required to be given under subsection (1) for a
contravention of section 4 to 7 the steps required to be described in paragraph 4 of subsection(2) shall include
1 A list of procedures that will be implemented as required by section 132 Based on the time requirements set out under subsection 14 (4) for each listed
procedure an indication of the date by which each element of the procedure will beimplemented
3 A written explanation of how each of the listed procedures will prevent or minimize the riskof any future contraventions of the section
(4) Subsection (3) does not apply if(a) the facility is an existing facility and the date is before July 1 2015 or(b) all of the information set out in subsection (3) has previously been submitted to the district
manager and the district manager is satisfied that the suspected cause of thecontravention and steps taken to prevent or minimize the risk of future contraventionswould be the same as in the information previously submitted
Implementation of Procedures 13 (1) Subject to subsection (4) if information is required to be submitted under subsection
12 (3) the owner and operator shall ensure that at least one of the procedures developed undersubsection 14 (3) is implemented at the facility
(2) Subject to subsection (3) the procedure required to be implemented under subsection (1)shall address the contravention for which the notice was given
(3) If no procedure developed under subsection 14 (3) addresses the contravention theowner and operator shall ensure that
(a) no later than 15 days after the notice is required to be given an action that addresses thecontravention is identified under subsection 14 (1) and
(b) the procedures developed under subsection 14 (3) in relation to the action areimplemented at the facility
(4) This section does not apply if the facility is an existing facility and the date is before July1 2015
Corrective Action Procedures 14 (1) Subject to subsection (6) for each of the following improvements the owner and
operator of a pulp and paper facility shall ensure that at least one action that could be taken toachieve the improvement is identified in a document entitled ldquoCorrective Action Proceduresrdquo
1 An increased removal of total reduced sulphur (TRS) compounds from processcondensate streams
2 A reduced loading of total reduced sulphur (TRS) compounds entering the wastewatertreatment system
102Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
3 A reduction in discharges into the air of total reduced sulphur (TRS) compounds from thewastewater treatment system
4 A reduced concentration of total reduced sulphur (TRS) compounds at the wastewaterambient monitor
5 A reduced concentration of total reduced sulphur (TRS) compounds at the communityambient monitor
6 A reduced concentration of carbon monoxide in the flue gas of a large wood-firedcombustor
(2) The actions required to be identified under subsection (1) shall include the actionsmentioned in the following subsections
1 Subsection 41 (2)2 Subsection 44 (3)3 Subsection 47 (2)(3) For each action identified in subsection (1) the owner and operator shall ensure that a
written procedure to implement the action is developed and included in the document entitledldquoCorrective Action Proceduresrdquo
(4) Each procedure developed under subsection (3) shall set out the time required toimplement each element of the procedure
(5) Actions identified with respect to the improvement mentioned in paragraph 5 ofsubsection (1) may include controlling discharges from lime kilns into the air and minimizing thedischarge of NCGs into the air
(6) This section does not apply if the facility mentioned in subsection (1) is an existing facilityand the date is before July 1 2015
Order for Specified Corrective Action Procedures 15 (1) If the Director has reasonable grounds to believe that a person has contravened any
of sections 4 to 7 the Director may order the person to take an action specified in the order toachieve one or more of the improvements mentioned in subsection 14 (1) that would addressthe contravention and to develop a written procedure to implement that action
(2) The order mentioned in subsection (1) may specify the following1 The date by which the action must be implemented2 Elements of the procedure mentioned in subsection (1) and dates by which the elements
shall be implemented3 An action that in the opinion of the Director may prevent or minimize the likelihood of an
adverse effect
PART III ndash OPERATIONAL PRACTICES
Steam Stripping of Process Condensate Streams 16 (1) No person shall transmit or cause or permit the transmission of any of the following
streams at a pulp and paper facility that uses the kraft process unless the streams are collectedin a closed system and transmitted to a steam stripper system
1 Process condensate streams from the blow steam generated in a batch digester2 Process condensate streams from the gas released from a batch digester relief gas vent3 Process condensate streams from the flash steam generated in a continuous digester4 Underflow stream from a turpentine decanter5 Process condensate streams from a system that collects concentrated NCGs(2) No person shall transmit or cause or permit the transmission of a process condensate
stream from an evaporator system at an existing pulp and paper facility that uses the kraft
103Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
process unless at least one of the process condensate streams is collected in a closed systemand transmitted to a steam stripper system
(3) No person shall transmit or cause or permit the transmission of a process condensatestream from an evaporator system at a new pulp and paper facility that uses the kraft processunless at least two of the process condensate streams are collected in a closed system andtransmitted to a steam stripper system
(4) A steam stripper system referred to in subsections (1) to (3) shall be capable ofaccommodating the volume of the streams that are required to be transmitted
(5) The Director may order the owner and operator of a pulp and paper facility that uses thekraft process to remove total reduced sulphur (TRS) compounds from a process condensatestream if
(a) the owner and operator were required to give notice with respect to the facility undersubsection 2 (2)
(b) the Director is of the opinion that the process condensate stream is contributing to thedischarge of total reduced sulphur (TRS) compounds into the air from the facility and thatthe discharge may cause an adverse effect and
(c) the adverse effect mentioned in clause (b) may be better prevented eliminated orameliorated if total reduced sulphur (TRS) compounds were removed from the processcondensate stream
Steam Stripper System By-Pass ndash Notification 17 (1) The owner and operator of a pulp and paper facility that uses a kraft process shall
ensure that a provincial officer is notified immediately if for more than one hour a processcondensate stream is redirected from treatment including if a process condensate stream isredirected from a steam stripper
(2) No later than 30 days after the notice under subsection (1) is required to be given theowner and operator shall ensure that the following information is submitted in writing to aprovincial officer
1 The date and time that the process condensate stream was redirected from treatment 2 The duration of the redirection mentioned in paragraph 1
3 An explanation of the suspected reason that the process condensate stream wasredirected
4 A description of any steps taken to prevent or minimize the risk of the process condensatestream being redirected in the future
Incineration ndash Semi-Chemical Process 18 No person shall transmit or cause or permit the transmission of a gas from a steam
reformer sodium carbonate pellet cooling conveyer sodium carbonate dissolving tank or aliquor concentrator at a pulp and paper facility that uses a semi-chemical pulp process unlessthe following conditions are met
1 The gas is collected and transmitted in a closed system2 The gas is incinerated by at least one of
i a power boiler orii a thermal oxidizer dedicated to the incineration of the gas
Failure of Incineration Device Semi-Chemical Process - Notification 19 (1) The owner and operator of a facility mentioned in section 18 shall ensure that a
provincial officer is notified immediately if both of the following circumstances occur 1 The gas mentioned in section 18 is discharged into the air
104Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
2 None of the devices mentioned in paragraph 2 of section 18 is available to incinerate thegas mentioned in section 18 and remains unavailable for more than one hour
(2) No later than 30 days after the notice under subsection (1) is required to be given theowner and operator shall ensure that the following information is submitted in writing to aprovincial officer
1 The date and time that the device mentioned in paragraph 2 of subsection (1) wasunavailable
2 The duration of the period that the device mentioned in paragraph 1 remained unavailable
3 An explanation of the suspected reason that the device was unavailable4 A description of any steps taken to prevent or minimize the risk of
i a future contravention of section 18 andii the gas being discharged into the air in the event of a future contravention of section
18
Incineration of NCGs ndash Kraft Process 20 (1) Subject to subsections (2) (3) and (6) no person shall transmit or cause or permit
the transmission of a concentrated NCG at a pulp and paper facility that uses the kraft processunless the following conditions are met
1 The concentrated NCG is collected and transmitted in a closed system2 The concentrated NCG is incinerated by at least one of the following devices
i A recovery boilerii A lime kilniii A power boileriv A thermal oxidizer dedicated to the incineration of the gas
3 No concentrated NCGs are discharged into the air(2) Subsection (1) does not apply if one of the devices in paragraph 2 of subsection (1) fails
to operate and the concentrated NCG is treated by a scrubber that uses alkaline solution(3) Subsection (1) does not apply if the following conditions are met1 In addition to the device required by paragraph 2 of subsection (1) at least one of
following devices capable of treating the concentrated NCG is also present at the facilityi A recovery boilerii A lime kilniii A power boileriv A thermal oxidizer dedicated to the incineration of the gasv A scrubber that uses alkaline solution to treat the gas
2 The discharge of the concentrated NCG into the air is prevented or minimized inaccordance with a written procedure
3 The concentrated NCG is discharged into the air for no more than 88-hours in any one-year period
4 The highest ranking employee is notified in writing as soon as practicable of the dischargeof the concentrated NCG into the air
(4) For the purpose of paragraph 3 of subsection (3) the discharge into the air of aconcentrated NCG remaining in the connection between a device mentioned in paragraph 2 ofsubsection (1) and one of the additional devices mentioned in subparagraphs 1 i to iv ofsubsection (3) shall be deemed not to be a discharge into the air
105Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(5) For the purpose of paragraph 3 of subsection (3) the discharge into the air of aconcentrated NCG from a defect shall be deemed not to be a discharge into the air if the defectis repaired by the date set out in section 37
(6) The Director may give a written notice to the person mentioned in subsection (1)indicating that subsection (1) does not apply to the person in respect of a specified concentrated NCG subject to such conditions as are specified by the Director if
(a) the person requests the notice in writing(b) the request mentioned in clause (a) identifies the source of contaminant that discharges
the specified concentrated NCG into the air and(c) the Director is satisfied that no adverse effect is likely to occur if the specified
concentrated NCG is not collected and incinerated in accordance with subsection (1)(7) No person shall operate or cause or permit the operation of a new pulp and paper facility
that uses the kraft process unless all dilute NCGs generated at the facility are collected in aclosed system and incinerated
(8) The Director may order the owner and operator of an existing pulp and paper facility thatuses the kraft process to collect in a closed system and incinerate dilute NCGs generated at thefacility if
(a) the owner and operator were required to give notice with respect to the facility undersubsection 2 (2)
(b) the Director is of the opinion that the dilute NCGs are contributing to discharges of totalreduced sulphur (TRS) compounds into the air from the facility and that such dischargesmay cause an adverse effect and
(c) the adverse effect mentioned in clause (b) may be better prevented eliminated orameliorated if the dilute NCGs were collected and incinerated
Failure of a Back-up Incineration Device (Concentrated NCG) Kraft Process ndash Notification 21 (1) Subject to subsections (2) and (5) the owner and operator of a pulp and paper facilitythat uses the kraft process shall ensure that a provincial officer is notified immediately if aconcentrated NCG is discharged into the air for more than 10 minutes
(2) If notice is required to be given under subsection (1) more than one time during acalendar day and a provincial officer has been notified of the discharge that first occurred in thecalendar day in accordance with subsection (1) subsection (1) does not apply to the subsequent discharges that would require that notice be given under subsection (1) if as soonas practicable after the end of the calendar day a provincial officer is notified of the number oftimes that notice would have to have been given under subsection (1) were this subsection notto apply
(3) If a discharge mentioned in subsection (1) continues for longer than a 24-hour period theowner and operator shall ensure that a provincial officer is notified at least once in every 24shyhour period that the discharge continues
(4) No later than 10 days after the notice under subsection (1) is required to be given theowner and operator shall ensure that the following information is submitted in writing to aprovincial officer
1 The date time and duration of the discharge2 The total amount of time that concentrated NCGs have been discharged into the air in the
preceding one-year period3 An explanation of the suspected reason for the discharge of the concentrated NCG into
the air and why it was not collected and incinerated in accordance with subsection 20 (1)4 A description of any steps taken to prevent or minimize the risk of
i a future contravention of subsection 20 (1) andii the gas being discharged into the air in the event of a future contravention of
subsection 20 (1)(5) Subsection (1) does not apply if the only concentrated NCG discharged into the air is the
gas remaining in the connection between a device mentioned in paragraph 2 of subsection 20
106Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(1) and a device used in the event of a failure of a device mentioned in paragraph 2 ofsubsection 20 (1)
(6) Despite subsection (5) subsection (1) does apply if the device used in the event of afailure of a device mentioned in paragraph 2 of subsection 20 (1) is a wet scrubber that uses analkaline solution
(7) If the Director is of the opinion that the steps required to be described in paragraph 4 ofsubsection (4) are insufficient to prevent or minimize the risks described in that paragraph theDirector may order a person mentioned in subsection (1) to take steps to prevent or minimizethe risks described in paragraph 4 of subsection (4)
Failure of an Incineration Device (Dilute NCG) Kraft Process - Notification 22 (1) If a dilute NCG is required by this industry standard to be incinerated the owner and
operator of a pulp and paper facility that uses the kraft process shall ensure that a provincialofficer is notified immediately if both of the following criteria are met
1 The incinerator is unavailable to incinerate the gas for more than one hour2 The dilute NCG is discharged into the air(2) No later than 30 days after the notice under subsection (1) is required to be given the
owner and operator shall ensure that the following information is submitted in writing to aprovincial officer
1 The date and time that the incinerator was unavailable 2 The duration of the period that the incinerator remained unavailable
3 An explanation of the suspected reason that the incinerator was unavailable4 A description of any steps taken to prevent or minimize the risk of
i the incinerator being unavailable in the future andii the gas being discharged into the air in the event that the incinerator is unavailable in
the future(3) If a dilute NCG is required by this industry standard to be treated using a method of
treatment other than incineration this section applies with necessary modifications to the othermethod of treatment
Procedures to Minimize Acrolein 23 (1) The owner and operator of a pulp and paper facility shall ensure that procedures to
prevent or minimize the discharge of acrolein into the air are developed and implemented withrespect to each of the following sources of contaminant at the facility
1 Unbleached kraft linerboard paper machine2 Tall oil reactor3 Weak black liquor storage tank vent4 Black liquor salt cake mix tank vent5 Brownstock washer6 Oxygen delignification system7 Bleach plant vent8 Thermo-mechanical pulping vent(2) For each source of contaminant listed in subsection (1) that is at the facility the
procedure mentioned in subsection (1) shall set out at least one method of preventing orminimizing the discharge of acrolein into the air
(3) A method mentioned in subsection (2) may include(a) the use of an air pollution control device
107Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(b) the selection and use of a source of contaminant that more effectively prevents orminimizes the discharge of a registered contaminant than another source of contaminantand
(c) the operation of a process in a manner that prevents or minimizes the discharge ofacrolein into the air from one or more sources of contaminant
(4) No person shall discharge or cause or permit the discharge of acrolein into the air from asource of contaminant listed in subsection (1) unless the discharge is made in accordance withthe procedure required by subsection (1)
Large Wood-fired Combustors - Combustion Air Requirements 24 No person shall operate or cause or permit the operation of a large wood-fired
combustor at a pulp and paper facility unless the air entering the furnace of the large wood-firedcombustor is sufficient to maintain the following levels of oxygen in the flue gas of the combustor
1 If the large wood-fired combustor uses suspension burners an oxygen level of at least 15per cent oxygen averaged over a three-hour period
2 If the large wood-fired combustor does not use suspension burners an oxygen level of atleast 40 per cent oxygen averaged over a three-hour period
Large Wood-fired Combustors - Air Pollution Control Devices 25 (1) If a large wood-fired combustor at a pulp and paper facility is attached to a baghouse
no person shall operate or cause or permit the operation of the baghouse unless it has at leastone bag leakage detection monitor operating
(2) If a large wood-fired combustor at a pulp and paper facility is attached to a wet scrubberno person shall operate or cause or permit the operation of the wet scrubber unless it has atleast one pressure drop monitor and at least one liquid flow monitor operating
(3) If a large wood-fired combustor at a pulp and paper facility is attached to an electrostaticprecipitator no person shall operate or cause or permit the operation of the electrostatic precipitator unless it has at least one power input monitor operating
Large Wood-fired Combustors - Fuel Management 26 (1) No person shall store or cause or permit the storage of wood fuel at a pulp and paper
facility that has a large wood-fired combustor unless the wood fuel is stored in accordance witha written wood fuel management plan
(2) The owner and operator of a facility mentioned in subsection (1) shall ensure that thewood fuel management plan mentioned in subsection (1) is developed and implemented
(3) The wood fuel management plan mentioned in subsection (1) shall contain the followinginformation
1 A list of the types of wood fuel that may be stored at the facility2 For each type of wood fuel listed in paragraph 1 an identification of parameters that will
demonstrate the storage quality of the wood fuel including size and moisture content3 For each parameter identified under paragraph 2 a determination of a range of values
within which the wood fuel will be considered of acceptable quality for storage at thefacility
4 A procedure to ensure that the wood fuel is tested to ensure that the value for eachparameter identified under paragraph 2 is within the range determined under paragraph 3for the parameter
5 A procedure to ensure the wood fuel is inspected on a regular basis and that theinspection includes an inspection of the pile and of the feed system
108Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
6 A procedure to ensure that wood fuel not considered acceptable for storage at the facilityis rejected and not stored at the facility
7 An indication of the maximum time that a wood fuel may be stored at the facility8 A pile turn-over procedure to ensure that wood fuel that has been at the facility longest is
used first9 A procedure to ensure that records are prepared and retained at the facility that set out
i the quantity of wood fuel purchased by the facility and the source from which it waspurchased
ii the quantity of wood fuel generated at the facility andiii the quantity of wood fuel rejected for storage at the facility in accordance with
paragraph 6 and the reasons for the rejection
New Large Wood-Fired Combustors - Residence Time amp Temperature 27 (1) Subject to subsection (2) no person shall operate or cause or permit the operation of
a new large wood-fired combustor at a pulp and paper facility unless it is designed to operate ina manner that ensures the flue gas in the furnace attains a temperature set out in Column 1 ofTable 4 - 2 7 for a residence time of at least the period set out opposite the residence time in Column 2 of Table 4-27
(2) Subsection (1) does not apply if the new large wood-fired combustor incorporatesfluidized-bed technology and is designed to operate in a manner that ensures the flue gas in thefurnace attains a temperature of 800oC for a residence time of at least 1 second
Table 4-27 New Large Wood-Fired Combustors ndash Residence Time amp Temperature
Item Column 1 Combustion Temperature
Column 2 Residence Time
1 1000 Degrees Celsius 1 second 2 900 Degrees Celsius 15 seconds 3 850 Degrees Celsius 2 seconds
Thermal Oxidizers ndash Residence time 28 (1) No person shall discharge or cause or permit the discharge of a gas from a thermal
oxidizer at a pulp and paper facility into the air unless the gas in the thermal oxidizer attains atemperature of at least 760oC for a residence time of at least 075 seconds
Brownstock Shower Water 29 (1) Subject to subsections (2) and (3) no person shall use or cause or permit the use of
a process condensate stream as shower water in the last stage of washing in the brownstockwasher at a pulp and paper facility that uses the kraft process
(2) Subsection (1) does not apply if(a) the facility is an existing facility and the date is before January 1 2015 or(b) all dilute NCGs generated by the brownstock washer are collected and incinerated(3) The Director may give written notice to the person mentioned in subsection (1) indicating
that subsection (1) does not apply to the person if (a) the person requests the notice in writing and(b) the Director is satisfied that the concentration of total reduced sulphur (TRS) compounds
in the process condensate stream would not result in a significant discharge of totalreduced sulphur (TRS) compounds into the air
109Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Bleaching of Pulp 30 No person shall use or cause or permit the use of elemental chlorine gas for the
bleaching of pulp at a pulp and paper facility that uses the kraft process
Heat Recovery 31 No person shall discharge or cause or permit the discharge of a gas from a refiner at a
pulp and paper facility that uses a thermo-mechanical process into the air unless the gas is at atemperature of less than 150oC
New Pulp and Paper Facility that Uses the Kraft Process - Wastewater Treatment System 32 No person shall operate or cause or permit the operation of a new pulp and paper facility
that uses the kraft process unless the wastewater generated by the facility is treated using anactivated sludge system
Air Pollution Control ndash Requirement to Continue 33 (1) For the purpose of this section ldquosourcerdquo means a thing that(a) is a source of contaminant or(b) would be a source of contaminant were it not attached to an air pollution control device
into which contaminants have been discharged from that thing(2) Subject to subsection (5) the owner and operator of a pulp and paper facility shall ensure
that a table is prepared in the following manner 1 The Table shall at a minimum contain 2 columns2 The first column shall be entitled ldquoTechnologyrdquo The column shall list each method used at
the facility to prevent or minimize the discharge of a registered contaminant3 The second column shall be entitled ldquoAssociated Sourcesrdquo The column shall opposite
each method listed in Column 1 list each source at the facility that is associated with themethod
(3) A method mentioned in paragraph 2 of subsection (2) includes a method such as(a) the use of an air pollution control device(b) the selection and use of a source that more effectively prevents or minimizes the
discharge of a registered contaminant than another source and(c) the operation of a process in a manner that prevents or minimizes the discharge of a
registered contaminant into the air from one or more sources(4) If a method mentioned in paragraph 2 of subsection (2) is the selection of a source in
accordance with clause (3) (b) the source shall be listed as the method in Column 1 of theTable required by subsection (2) and as the source in Column 2 of the Table
(5) If a new facility is not constructed at the time of registration the methods required to belisted in Column 1 and the sources required to be listed in Column 2 of the Table required bysubsection (2) shall until the construction is complete be the proposed methods and sources
(6) Each method used by the facility to collect and treat dilute NCGs shall be listed in Column1 of the Table required by subsection (2)
(7) If a source that may discharge a registered contaminant is replaced or added to thefacility the owner and operator shall ensure that the following steps are performed
1 Determine if the replaced or added source is of a similar type to a source listed in Column2 of the Table required by subsection (2)
2 If the determination required by paragraph 1 is affirmativei identify the method listed in Column 1 opposite the sourceii if there is more than one source listed in Column 2 that is similar to the replaced or
added source identify the method listed in Column 1 opposite each similar source
110Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
iii if more than one method is required to be identified under subparagraph ii identify themethod that is the most effective at preventing or minimizing the discharge of aregistered contaminant
(8) No later than 30 days after any of the following changes occur the owner and operator ofa pulp and paper facility shall ensure that the Table required by subsection (2) is updated in thefollowing manner
1 If a new method to prevent or minimize the discharge of a registered contaminant is beingused at the facility the method shall be listed in Column 1 of the Table and each sourceassociated with the method shall be listed opposite the method in Column 2 of the Table
2 If the determination required by paragraph 1 of subsection (7) is affirmative the sourceshall be listed in Column 2 of the Table and a method that is at least as effective as themethod identified in paragraph 2 of subsection (7) shall be listed opposite the source inColumn 1
3 Subject to subsection (9) if there is a change to a method required to be listed in Column1 of the Table the change in method shall be listed in Column 1 of the Table
4 If a source listed in Column 2 of the Table is removed from the facility the source shall beremoved from the Table
5 If all sources associated with a method listed in Column 1 of the Table have beenremoved from the Table the method shall be removed from the Table
6 If a notice issued under subsection (11) indicates that a method is no longer necessarythe method shall be removed from Column 1 of the Table and the associated sourceslisted opposite the method shall be removed from Column 2 of the Table
(9) A change mentioned in paragraph 3 of subsection (8) shall be one of one of the followingchanges
1 A change to a method that results in a method that is at least as effective at preventing orminimizing the discharge of registered contaminants as the method that was previouslylisted in the Table
2 A change to a method that is authorized by a notice issued under subsection (11)3 A change to a method that is required by an order issued under subsection (12)4 A change to a method that is required by a section of this industry standard other than
this section(10) Subject to subsection (11) no person shall operate or cause or permit the operation of a
source required to be listed in Column 2 of the Table required by subsection (2) unless thedischarge of registered contaminants from the source is prevented or minimized by a methodthat is at least as effective at preventing or minimizing the discharge into the air as the associated method listed opposite the source in Column 1 of the Table
(11) The Director may give written notice to the person mentioned in subsection (2) indicatingthat a person may operate in accordance with the notice a source required to be listed inColumn 2 of the Table required by subsection (2) if the discharge of registered contaminantsfrom the source is prevented or minimized by a method that is less effective at preventing orminimizing the discharge into the air than the associated method listed opposite the source inColumn 1 of the Table if
(a) the person requests the notice in writing(b) the notice required by clause (a) contains a rationale for the request(c) the source specified in the request is not a source subject to a requirement under this
industry standard other than a requirement under this section and(d) the Director is of the opinion that
(i) the specified source is controlled by a method that is less effective at preventing orminimizing the discharge of registered contaminants into the air than the methodrequired to be recorded under subsection (2) and the effectiveness of the method iscomparable to the effectiveness of the method required to be recorded undersubsection (2)
111Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(ii) the specified source is controlled by a method that is less effective at preventing orminimizing the discharge of registered contaminants into the air than the methodrequired to be recorded under subsection (2) and any adverse effect that may becaused by discharges of the contaminant from the specified source into the air wouldlikely not be better prevented eliminated or ameliorated if the method required to berecorded under subsection (2) were used
(iii) no adverse effect is likely to occur if the specified source is not controlled by amethod or
(iv) the registered contaminants discharged from the specified source are discharged inan amount that is negligible
(12) The Director may order the person mentioned in subsection (2) to use a specifiedmethod to prevent or minimize the discharge of a registered contaminant into the air from asource if
(a) an assertion is made in accordance with subclause (16) (c) (i) in a notice required to begiven under subsection (13) and the Director is of the opinion that the method is not aseffective at preventing or minimizing the discharge into the air as the method previouslylisted in the Table or
(b) the source is or in an earlier version has been listed in Column 2 of the Table requiredby subsection (2) and the Director is of the opinion that the discharge may cause anadverse effect
(13) No later than 30 days after a source that discharges a registered contaminant isreplaced or added to the facility the owner and operator of a pulp and paper facility shallensure that a provincial officer is notified in writing of the replacement or addition
(14) Subsection (13) does not apply if the source discharges a registered contaminant in anamount that is negligible
(15) If the notice required by subsection (13) is with respect to a source for which adetermination required by paragraph 1 of subsection (7) is affirmative the notice shall include
(a) a description of the source(b) a description of the method required to be listed under paragraph 2 of subsection (8)(c) a description of the method required to be identified in paragraph 2 of subsection (7)(d) an explanation of how the method mentioned in clause (b) is at least as effective as the
method mentioned in clause (c)(16) If the notice required by subsection (13) is with respect to a source that is a method
listed in Column 1 of the Table required by subsection (2) the notice shall include (a) a description of the method(b) a list of the sources set out in Column 2 of the Table opposite the method and(c) one of the following assertions
(i) an explanation of how the method is at least as effective at preventing or minimizingthe discharge of registered contaminants as the method that was previously listed inthe Table
(ii) a reference to the notice issued under subsection (11) that authorized the change inmethod
(iii) a reference to the order issued under subsection (12) that required the change inmethod or
(iv) a reference to the section of this industry standard that requires the change inmethod
(17) No later than 30 days after a significant modification has been made to a large wood-fired combustor the owner and operator of a pulp and paper facility shall ensure that
(a) a provincial officer is notified in writing of the significant modification and(b) the notification required by clause (a) includes the following information
(i) the intensity expressed as a mass per unit heat input capacity of the emissions ofparticulate and benzo(a)pyrene prior to the significant modification
112Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(ii) an estimate of the intensity expressed as a mass per unit heat input capacity of theemissions of particulate and benzo(a)pyrene after the significant modification iscompleted and
(iii) a description of the significant modification and an explanation of how the modificationresulted in an increase in the intensity of the emissions of particulate andbenzo(a)pyrene
Specified Air Pollution Control Devices 34 (1) No person shall operate or cause or permit the operation of a source of contaminant
set out in Column 1 of Table 4-34 at a pulp and paper facility that uses the kraft process unless all contaminants that may be discharged to the air generated by the source are collected and transmitted to the air pollution control device set out opposite the source ofcontaminant in Column 2
(2) Subject to subsection (3) and for the purposes of subsection (1) the air pollution controldevice set out in Items 4 5 and 6 of Column 2 of Table 4-34 shall
(a) remove at least 99 per cent of chlorine dioxide from the gas entering the device or(b) not discharge into the air a gas that contains more than 10 ppm of chlorine dioxide(3) Before July 1 2015 the following provisions do not apply to an existing pulp and paper
facility 1 Subsection (1) with respect to Items 4 5 and 6 of Table 4-342 Subsection (2)
Table 4-34 Specified Air Pollution Control Devices
Item Column 1
Source of Contaminant
Column 2
Air Pollution Control Device
1 A tall oil reactor A wet scrubber that uses an alkaline solution
2 A smelt dissolving tank A wet scrubber that uses an alkaline solution or a recovery boiler
3 A slaker A wet scrubber
4 A bleach plant chlorine dioxide storage vent A wet scrubber that uses alkaline solution
5 A bleach plant chlorine dioxide generator A wet scrubber that uses alkaline solution
6 A bleach plant chlorinated-stage washer hood A wet scrubber that uses alkaline solution
7 A recovery boiler An electrostatic precipitator
8 A lime kiln An electrostatic precipitator or wet scrubber
113Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Facility ndash Parameter Summary Table 35 (1) Subject to subsections (2) and (4) the owner and operator of a pulp and paper facility
shall ensure that a table labelled ldquoParameter Summary Tablerdquo is prepared that reproducesTable 4-35 in a manner that includes all technologies listed in Column 1 of Table 4 - 3 5 that are at the facility and associated with a registered contaminant
(2) Subject to subsection (3) the value in Columns 5 and 6 for Item 7 of Table 4-35 shallbe at least 80 solids in the black liquor for a recovery boiler if either of the following criteria is met
1 The recovery boiler is part of a new pulp and paper facility2 The recovery boiler was installed at an existing facility after March 31 2014(3) The Director may give written notice to the person mentioned in subsection (1) indicating
that paragraph 2 of subsection (2) does not apply to the person if (a) the person requests the notice in writing and(b) the Director is satisfied that it is not feasible to operate the recovery boiler with at least
80 solids in the black liquor(4) Subject to subsection (5) a person who is required under subsection (1) to reproduce
Item 4 in the Parameter Summary Table for the facility does not have to set out the informationin Columns 3 to 7 of Item 4 of Table 4-35 if the person sets out the information in the followingmanner
1 Column 3 Corona Power Input2 Column 4 A location that would allow measurement of voltage and current from the field3 Column 5 A value that is consistent with professional recommendations4 Column 6 A value that does not meet the criteria set out in Column 55 Column 7 In three days of any seven-day period the parameter is a value that does not
meet the criteria set out in Column 5 averaged over a 12-hour period(5) Subsection (4) does not apply with respect to an electrostatic precipitator at the facility if(a) the electrostatic precipitator is associated with a large wood-fired combustor that has a
heat input capacity greater than 50 MW(b) the large wood-fired combustor mentioned in clause (a) is not a direct contact dryer and(c) the date is on or after July 1 2016(6) For the purpose of subsection (1) where Table 4-35 refers to a parameter location or
value that is to be consistent with a recommendation made by a professional the owner andoperator shall ensure that the Parameter Summary Table sets out the recommended parameterlocation or value and the source of the recommendation
(7) If a range of values is provided by a professional pursuant to subsection (6) the range ofvalues shall be considered the value for the purposes of this section
(8) The source of the recommendation made by a professional mentioned in subsection (6)shall be one of the following documents
1 The manufacturerrsquos operating manual2 A letter from the manufacturer specifying the recommendation3 A letter from a professional engineer who has experience with the technology
specifying a recommendation and the rationale for the recommendation(9) The person mentioned in subsection (1) shall ensure that the Parameter Summary Table
is updated to reflect any of the following changes no later than 30 days after the change occurs 1 A revision is made to a recommendation made by a professional2 A technology referred to in Item 10 of Table 4-35 is added or changed if the technology is
associated with a registered contaminant3 A source of contaminant associated with a technology set out in Column 1 is added or
replaced (10) If the Director has reasonable grounds to believe that a value recommended for the
purposes of subsection (6) is inappropriate for proper operation of the technology the Director
114Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
may give written notice to the owner and operator of a pulp and paper facility specifying adifferent value
(11) Before the Director gives a person notice under subsection (10) the Director shall givethe person a draft of the notice and an opportunity to make written submissions to the Directorduring the period that ends 30 days after the draft is given
Table 4-35 Facility ndash Structure for Parameter Summary Table
Item Column 1
Technology
Column 2
Associated Sources
Column 3
Parameter
Column 4
Measurement Location
Column 5
Normal Value
Column 6
Deviation Value
Column 7
Notification Value
1 Wet scrubber
Sources of contaminant that are controlled by the technology set out in Column 1
Scrubbing liquid flow rate (Lmin)
Inlet to the scrubber
A value that is consistent with professional recommendations
A value that does not meet the criteria set out in Column 5
In three days of any seven-day period the parameter is a value that does not meet the criteria set out in Column 5 averaged over a 12shyhour period
Pressure differential (inches of water)
1Inlet to thescrubber
2Outlet of thescrubber
A value that is consistent with professional recommendations
A value that does not meet the criteria set out in Column 5
In three days of any seven-day period the parameter is a value that does not meet the criteria set out in Column 5 averaged over a 12shyhour period
115Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Technology
Column 2 Associated Sources
Column 3
Parameter
Column 4 Measurement Location
Column 5
Normal Value
Column 6 Deviation Value
Column 7 Notification Value
2
Wet scrubber ndash with alkaline solution
Sources of contaminant that are controlled by the technology set out in Column 1
Scrubbing liquid flow rate (Lmin)
Inlet to the scrubber
A value that is consistent with professional recommendations
A value that does not meet the criteria set out in Column 5
In three days of any seven-day period the parameter is a value that does not meet the criteria set out in Column 5 averaged over a 12shyhour period
Pressure differential (inches of water)
1 Inlet to thescrubber
2 Outlet of thescrubber
A value that is consistent with professional recommendations
A value that does not meet the criteria set out in Column 5
In three days of any seven-day period the parameter is a value that does not meet the criteria set out in Column 5 averaged over a 12shyhour period
pH of scrubbing liquid
The locations required to be recorded under subsection 49 (5)
A value that is consistent with professional recommendations
A value that does not meet the criteria set out in Column 5
In three days of any seven-day period the parameter is a value that does not meet the criteria set out in Column 5 averaged over a 12shyhour period
116Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1 Column 2 Column 3 Column 4 Column 5 Column 6 Column 7
Technology Associated Sources Parameter Measurement
Location Normal Value Deviation Value
Notification Value
Sources of contaminant
A value that is consistent with professional recommendations A value that
In three days of any seven-day period the parameter is
3 Thermal oxidizer
that are controlled by the
Temperature At the point that represents a residence time of
does not meet the criteria set
a value that does not meet the
technology 075 seconds The out in criteria set set out in recommendation Column 5 out in Column 1 shall be a
temperature of at least 760oC
Column 5 averaged over a 12shyhour period
4
Electrostatic precipitator subject to subsection (4)
Sources of contaminant that are controlled by the technology set out in Column 1
Opacity Immediately before the outlet of the stack of the electrostatic precipitator
20 averaged over a six-minute averaging period
Opacity is greater than 20 per cent averaged over a six-minute period
117Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Technology
Column 2 Associated Sources
Column 3
Parameter
Column 4 Measurement Location
Column 5
Normal Value
Column 6 Deviation Value
Column 7 Notification Value
5
Lime kiln Sources of contaminant that are controlled by the technology set out in Column 1
Percentage of the flue gas that is oxygen
Outlet of the kiln
1 If the lime kilnis incineratingconcentratedNCGs at least15 oxygen byvolume on a drybasis
2 If the lime kilnis only beingused to calcineat least 05oxygen byvolume on a drybasis
1 If the limekiln isincineratingconcentratedNCGs theper centoxygen isless than15averagedover a half-hour period
2 If the limekiln is onlybeing usedto calcinethe per centoxygen isless than05averagedover a half-hour period
1 If the limekiln isincineratingconcentratedNCGs ineach day ofany three-day periodthe per centoxygen isless than15averagedover a three-hour period
2 If the limekiln is onlybeing usedto calcine ineach day ofany three-day periodthe per centoxygen isless than05averagedover a three-hour period
Percentage of sodium in lime mud
Kiln feed from the lime mud filter
No more than 15 sodium in lime mud
The per cent sodium exceeds 15
In three days of any seven-day period the per cent sodium in lime mud exceeds 15
6 Steam stripper
Sources of contaminant that are controlled by the
Steam-toshycondensate ratio
1 Steam inlet tosteam stripper At least 015 kg
of steam kg of condensate
The ratio of steam to condensate is less than 015
In three days of any seven-day period the ratio of steam to condensate
technology set out in Column 1
2Condensateinlet to steamstripper
averaged over a one-hour period
is less than 015 averaged over a 12shyhour period
118Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Technology
Column 2 Associated Sources
Column 3
Parameter
Column 4 Measurement Location
Column 5
Normal Value
Column 6 Deviation Value
Column 7 Notification Value
7
Recovery boiler subject to subsection (2)
Sources of contaminant that are controlled by the technology set out in Column 1
Percentage solids that is in black liquor
Black liquor feed at a point immediately before entering the boiler
At least 60 solids in the black liquor
Less than 60 solids in the black liquid averaged over a one-hour period
NA
8
Aerated stabilization basin system
NA
pH Inlet to aerated stabilization basin system
68
pH is less than 68 averaged over a six-hour period
In three days of any seven-day period pH is less than 68 averaged over a 12shyhour period
Dissolved oxygen (DO)
Outlet of each aerated stabilization basin cell that contains an aerator
At least 04 ppm
Dissolved oxygen is less than 04 ppm
In three days of any five-day period the dissolved oxygen is less than 04 ppm
9 Wastewater treatment system
NA pH
Inlet to primary treatment 68
pH is less than 68 averaged over a six-hour period
In three days of any seven-day period pH is less than 68 averaged over a 12shyhour period
10
Method required by s 23 (1) ors 33 (2)
Sources of contaminant that are controlled by the technology set out in Column 1
A parameter consistent with professional recommendations
A location consistent with professional recommendations
A value that is consistent with professional recommendations
A value that does not meet the criteria set out in Column 5
In three days of any seven-day period the parameter is a value that does not meet the criteria set out in Column 5
Facility ndash Deviation from Operational Parameters 36 (1) For each technology listed in Column 1 of the Parameter Summary Table required by
section 35 the owner and the operator of a pulp and paper facility shall ensure that theinformation set out in subsection (2) is recorded if the value for a parameter set out in Column 3
119Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
of the Table opposite the technology measured at each location set out in Column 4 of theTable opposite the parameter deviates from the value set out in Column 6 of the Table
(2) For the purposes of subsection (1) the following information is required to be recorded1 The date time and duration of the deviation2 The value measured for the parameter set out in Column 3 of the Parameter Summary
Table required by section 35 and a comparison to the value set out in Column 5 of theTable
3 An explanation of the suspected cause of the deviation4 A description of the operational adjustments made to correct the deviation and the dates
the adjustments were made5 The names of the personnel assigned to make the operational adjustments(3) Subject to subsection (4) the owner and operator of a pulp and paper facility shall ensure
that as soon as practicable a provincial officer is notified in writing if the value of a parameterlisted in Column 3 of the Parameter Summary Table required by section 35 at a location set outopposite the parameter in Column 4 deviates from the value set out opposite in Column 7 of theTable
(4) Subsection (3) does not apply with respect to the pH requirements set out in Item 8 or 9of Table 4-35 if
(a) the result of the most recent calculation of the daily hydrogen sulphide loading determinedin accordance with Item 10 of Table 4 - 4 9 is less than 005 kg hydrogen sulphideper tonne of ADUP or
(b) the facility is not pulping
Inspection and Maintenance 37 (1) If one or more of the following technologies are associated with a registered
contaminant the owner and operator of a pulp and paper facility shall ensure the technology isinspected and maintained in accordance with a recommendation made by a professional
1 Evaporator system2 Digester system3 Turpentine recovery system4 Steam stripper system5 System that collects NCGs6 Any technology listed in Column 1 of Table 4-35(2) The source of the recommendation made by a professional mentioned in subsection (1)
shall be one the following documents 1 The manufacturerrsquos operating manual2 A letter from the manufacturer specifying the recommended inspection or maintenance3 A letter from a professional engineer who has experience with the technology specifying
recommended inspection or maintenance practices and the rationale for the specification(3) At least once in every 30-day period the inspection required by subsection (1) shall
include an inspection for visible evidence of defects of each duct pipe enclosure and connection in the following closed systems
1 If section 18 applies in respect of the facility each closed system required by section 182 If section 20 applies in respect of the facility each closed system required by section 203 Each closed system recorded for the purpose of subsection 33 (6)(4) Subject to subsection (5) if the facility is a pulp and paper facility that uses the kraft
process the owner and operator of the facility shall ensure that each defect observed as aresult of the inspection required by subsection (3) is repaired no later than 15 days after thedefect was observed
120Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(5) Subsection (4) does not apply if(a) a device connected to the closed system must be shut down in order to repair a defect
and(b) the device is shut down and the repair is completed by the earlier of
(i) the date on which the device begins operation again and(ii) a date specified in writing by the district manager
(6) The person mentioned in subsection (1) shall ensure that the following information isrecorded
1 The date and results of inspections and maintenance required by subsection (1)2 The source of the recommendation made by a professional required by subsection (2)
Process Loss ndash Best Management Practices 38 (1) The owner and operator of a pulp and paper facility that uses the kraft process shall
ensure that written practices to prevent or minimize process loss at the facility are prepared(2) No person shall act in a manner that is inconsistent with the practices required by
subsection (1)(3) The owner and operator of a pulp and paper facility that uses the kraft process shall
ensure that the practices required by subsection (1) are set out in a document entitled lsquorsquoProcessLoss ndash Best Management Practicesrdquo
(4) The owner and operator of a pulp and paper facility that uses the kraft process shallensure that the practices required by subsection (1) are updated to include
(a) as required by subsection 44 (4) any action identified in the report required by subsection44 (1) that is reasonably feasible to implement at the facility
(b) any action identified in the report required by subsection 44 (1) that is implemented at thefacility and
(c) any action required by an order issued under subsection 15 (1) if the action relates to theminimization of process loss
(5) The owner and operator of a pulp and paper facility that uses the kraft process shallensure that the following information is recorded for any abnormal process loss
1 The date time and duration of the process loss2 A description and estimated amount of the process loss3 An explanation of the suspected cause of the process loss4 A description of the activities performed to address the process loss and the dates the
activities were completed5 The names of the personnel assigned to perform the activities mentioned in paragraph 4
Bi-Annual Adjustment of Large Wood-fired Combustor Operation 39 (1) Subject to subsection (3) at least one time in every two-year period the owner and
operator of a pulp and paper facility with a large wood-fired combustor shall for each largewood-fired combustor at the facility ensure that the following actions are taken
1 Determine whether the large wood-fired combustor is operating properly by inspectingi fuel handling equipmentii fuel distribution equipmentiii air dampersiv air measurement devices andv grates and burners
2 Conduct a combustion test that includes
121Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
i visually observing the combustion occurring in the large wood-fired combustorii measuring the amount of air entering the large wood-fired combustoriii measuring the oxygen and carbon monoxide in the flue gas in accordance with
section 54iv determining the ratio of the amount of air entering the large wood-fired combustor to
the amount of wood fuel entering the large wood-fired combustorv comparing the ratio determined under paragraph iv with the ratio at which the large
wood-fired combustor was designed to operate andvi determining the ratio of energy output from the large wood-fired combustor to the heat
input of the large wood-fired combustor for example the steam flow to bark ratio3 Determine if the large wood-fired combustor is performing well by reviewing
i the results of the combustion test required by paragraph 2ii the concentration of carbon monoxide and oxygen in the flue gas measured in
accordance with section 54 andiii information including any calibration information to demonstrate whether the
continuous emissions monitoring system required by subsection 54 (1) is operating inaccordance with the manufacturerrsquos recommendations
(2) If the determination required by paragraph 3 of subsection (1) indicates that the largewood-fired combustor is not performing well the owner and operator shall ensure that the ratiomentioned in subparagraph 2 iv of subsection (1) is adjusted in a manner that will improve theperformance of the large wood-fired combustor
(3) If any of the requirements set out in subsection (1) conflict with a manufacturerrsquosrecommendation the requirement does not apply to the person mentioned in subsection (1) tothe extent that it conflicts with the manufacturerrsquos recommendation
(4) For greater certainty subsection (1) does not replace any inspection or preventativemaintenance program recommended by the manufacturer and such recommendations shall beimplemented in addition to the requirements in subsection (1)
PART IV ndash OPERATIONAL OPTIMIZATION ASSESSMENTS
Treatment of Process Condensate Streams ndash Assessment Report 40 (1) The owner and operator of a pulp and paper facility that uses the kraft process shall
ensure that a report is prepared that identifies all process condensate streams at the facility andthe following information for each process condensate stream
1 The source from which the process condensate stream originates2 Subject to subsection (2) the highest daily flow rate of the process condensate stream
that would occur under normal operating conditions3 Subject to subsection (2) the concentration of total reduced sulphur (TRS) compounds in
the process condensate stream determined byi measuring in accordance with subsection 1 (5) the concentration of total reduced
sulphur (TRS) compounds at least once in every three-month period during a 12shymonth period
ii for each day when a measurement is made under subparagraph i recording the dailyproduction rate
iii subject to subparagraph iv assigning the highest measurement taken undersubparagraph i to be the concentration of total reduced sulphur (TRS) compounds inthe process condensate stream and
iv if the concentration assigned under subparagraph iii is not representative of thehighest concentration of total reduced sulphur (TRS) compounds in the process
122Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
condensate stream that would occur under normal operating conditions assigning aconcentration that would be representative and providing rationale for the assignment
4 The highest daily loading of total reduced sulphur (TRS) compounds in the processcondensate stream calculated by multiplying the value determined under paragraph 2 bythe value determined under paragraph 3
5 The destination of the process condensate stream including whether it is destined fori use as wash waterii treatment by a steam stripper systemiii a method of treatment other than by a steam stripper system oriv the wastewater treatment system
(2) The values required to be determined under paragraphs 2 and 3 of subsection (1) may beestimated in the first report prepared in respect of the facility mentioned in subsection (1) if thefacility is
(a) a new facility that has not started to operate on or before the date that the report requiredunder subsection (1) must first be completed or
(b) an existing facility that has not used the kraft process during the 12-month periodpreceding the date that this section first applies in respect of the facility in accordance withsection 3
(3) For each steam stripper system identified as a destination in subparagraph 5 ii ofsubsection (1) the report required by subsection (1) shall include an indication of the designcapacity of the steam stripper expressed in litres of process condensate treated per minute anda quantification of any unused capacity
(4) For each method of treatment identified as a destination under subparagraph 5 iii ofsubsection (1) the report required by subsection (1) shall include an evaluation of the percentage of total reduced sulphur (TRS) compounds that is removed from each processcondensate stream by the method of treatment
Treatment of Process Condensate Streams ndash Optimization Report 41 (1) Subject to subsection (3) the owner and operator of a pulp and paper facility that
uses the kraft process shall ensure that a report is prepared that (a) ranks the process condensate streams identified in subsection 40 (1) based on the
concentration of total reduced sulphur (TRS) compounds as determined under paragraph3 of subsection 40 (1)
(b) ranks the process condensate streams identified in subsection 40 (1) based on theloading of total reduced sulphur (TRS) compounds as determined under paragraph 4 ofsubsection 40 (1)
(c) for each of the highly ranked streams under clause (a) and for each of the highly rankedstreams under clause (b) identifies actions that could be taken to ensure the stream istreated including at least one of(i) redirecting the process condensate stream to a steam stripper system identified in
subsection 40 (3) as having unused capacity(ii) replacing a process condensate stream currently being treated by a steam stripper
system with a process condensate stream that has a higher concentration or loadingof total reduced sulphur (TRS) compounds
(iii) increasing steam stripper system capacity and(iv) treating the process condensate stream by a method other than by a steam stripper
system if the method would remove at least as much of the total reduced sulphur(TRS) compounds as a steam stripper system and
(d) for each process condensate stream that is not being treated by a steam stripper systemprovides reasons why the stream is not being treated including whether the treatment is
123Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
feasible for the stream and whether the stream is not being treated so that anotherprocess condensate stream can be treated instead
(2) The owner and operator shall ensure that each action identified under clause (c) ofsubsection (1) is identified as an action under subsection 14 (1) and that procedures to implement the action are developed under subsection 14 (3)
(3) If the date of application for registration in respect of the facility mentioned in subsection(1) is on or before March 31 2015 this section does not apply to the facility for the six-monthperiod following the date of registration
Steam Stripping Assessment and Optimization Update 42 (1) The owner and operator of a pulp and paper facility that uses the kraft process shall
ensure that the reports required by sections 40 and 41 are updated in accordance with thissection
(2) Subject to subsection (7) the reports required by sections 40 and 41 shall be updated if(a) notice is required to be given under subsection 12 (1) of a contravention of sections 4 5
or 6 and(b) the procedure required to be implemented under subsection 13 (1) is one of the
procedures mentioned in subsection 41 (2)(3) The update required by subsection (2) shall be completed no later than six months after
the last date specified in paragraph 2 of subsection 12 (3) and shall at minimum includeupdating the following information
1 The destination of each process condensate stream at the facility as required byparagraph 5 of subsection 40 (1)
2 Actions that could be taken to treat process condensate streams as required by clause (c)of subsection 41 (1)
(4) Subject to subsection (5) at least one time in every four-year period all of the informationin the reports required under subsection 40 and 41 shall be updated
(5) The Director may give written notice to the person mentioned in subsection (1) indicatingthat subsection (4) does not apply to the person in respect of the facility mentioned in subsection (1) for a specified four-year period if the person requests the notice in writing nolater than the first day of the fourth year in the four-year period and no earlier than the first dayof the third year in the four-year period and
(a) the person has not been given a notice under this section in respect of the previous four-year period and at the time that the request is made a procedure under subsection 41 (2)is being implemented at the facility or
(b) in the two-year period preceding the date of the request no notice has been required tobe given under subsection 12 (1) of a contravention of sections 4 5 or 6 and the Directoris of the opinion that it is not necessary to identify additional actions under clause (c) ofsubsection 41 (1)
(6) In considering a request made under clause (a) of subsection (5) the Director mayconsider the number of previous requests made under subsection (4)
(7) This section does not apply if the facility mentioned in subsection (1) is an existing facilityand the date is before July 1 2015
Process Loss Assessment Report 43 The owner and operator of a pulp and paper facility that uses the kraft process shall
ensure that a report is prepared that contains the following information 1 Identification of key process areas which have the potential to produce a process loss2 For each process area identified in paragraph 1 identification of equipment that may be
the source of a process loss including storage tanks and pipelines3 For each piece of equipment identified in paragraph 2 identification of controls and
procedures that are in place to minimize process loss including secondary containmentalarms detection and sumps
124Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Process Loss Minimization Report 44 (1) Subject to subsection (5) the owner and operator of a pulp and paper facility that
uses the kraft process shall ensure that a report is prepared that based on the informationcontained in the report required by section 43 identifies actions that are different than oradditional to those required by section 38 that would minimize the amount of process loss at thefacility
(2) The report required by subsection (1) shall identify the following actions1 Installing controls to prevent or minimize process loss from the equipment identified in
paragraph 2 of section 432 Installing instrumentation to monitor process loss3 Implementing procedures to ensure the instrumentation mentioned in paragraph 2 is
calibrated and maintained on a regular basis4 Implementing procedures to alert personnel who operate the facility that process loss is
imminent and to ensure that appropriate steps are taken to prevent minimize or respondto the process loss
5 Implementing procedures to educate operators maintenance personnel and othertechnical and supervisory personnel at the facility with respect to the significance ofprocess loss
6 Implementing procedures to train operators maintenance personnel and other technicaland supervisory personnel at the facility in process loss prevention minimization andresponse
(3) The owner and operator shall ensure that each action identified in subsection (1) isidentified as an action under subsection 14 (1) and that procedures to implement the action aredeveloped under subsection 14 (3)
(4) Subject to subsection (5) the owner and operator of a pulp and paper facility that usesthe kraft process shall ensure that the best management practices required by section 38include all actions identified in the report required by subsection (1) that are reasonably feasibleto implement
(5) If the date of application for registration in respect of the facility mentioned in subsection(1) is on or before March 31 2015
(a) Subsection (1) does not apply to the facility for the three-month period following the dateof registration and
(b) Subsection (4) does not apply to the facility for the six-month period following the date ofregistration
Process Loss Assessment and Minimization Update 45 (1) The owner and operator of a pulp and paper facility that uses the kraft process shall
ensure that the reports required by sections 43 and 44 are updated in accordance with thissection
(2) Subject to subsection (4) the reports required by sections 43 and 44 shall be updated if(a) notice is required to be given under subsection 12 (1) of a contravention of sections 4 5
or 6 and(b) the procedure required to be implemented under subsection 13 (1) is one of the
procedures mentioned in subsection 44 (3)(3) The update mentioned in subsection (2) shall be completed no later than six months after
the last date specified in paragraph 2 of subsection 12 (3)(4) If during a three-year period the reports required by sections 43 and 44 have not been
updated the reports shall be updated no later than the last day of the month that immediatelyfollows the three-year period
(5) This section does not apply if the facility mentioned in subsection (1) is an existing facilityand the date is before July 1 2015
125Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Wastewater Treatment System ndash Assessment Plan and Report 46 (1) Subject to subsection (6) the owner and operator of a pulp and paper facility that
uses the kraft process and that has an aerated stabilization basin system shall ensure that anassessment plan is prepared that
(a) identifies all operating parameters that affect the discharge of total reduced sulphur (TRS)compounds into the air from the wastewater treatment system including all of theparameters set out in Column 1 of Table 4-46
(b) for each parameter identified in clause (a) specifies the locations at which the parametershall be measured including the locations set out opposite the parameter in Column 2 ofTable 4-46 and
(c) for each location identified in clause (b) establishes a procedure that will result in anaccurate measurement including the procedure set out opposite the location in Column 3of Table 4-46
(2) The owner and operator of the facility shall ensure that all of the parameters mentioned inclause (1) (a) are measured at the locations mentioned in clause (1) (b) using the measurementprocedures mentioned in clause (1) (c)
(3) The measurements required by subsection (2) shall be taken during a period ofassessment in which the date of the final measurement taken for the purposes of subsection (2)is no later than five days after the date of the first measurement taken for the purposes ofsubsection (2)
(4) On each day that a measurement required by subsection (2) is taken the owner andoperator of the facility shall ensure that the daily production rate of the facility is recorded
(5) The owner and operator of the facility shall ensure that an assessment report iscompleted that includes the following information
1 The value of each measurement required by subsection (2) and the date on which eachmeasurement was taken
2 The daily production rate information required by subsection (4) and a calculation of thedaily production rate averaged over the period of assessment described in subsection (3)
3 The daily production rate calculated under paragraph 2 expressed as a percentage ofi the daily production rate capacity of the facility andii the average daily production rate of the facility
4 A diagram of the aerated stabilization basin system showingi the flow patternii the type and location of each aerator andiii each location at which a measurement required by subsection (2) was taken
(6) With respect to the first report required to be completed under subsection (5) the Directormay deem information gathered before February 1 2013 to be the information required bysubsection (5) if
(a) the information is submitted to the Director on or before the date that this section firstapplies in respect of the facility in accordance with section 3 and
(b) in the opinion of the Director the information substantially meets the requirements of thissection
126Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Table 4-46 Wastewater Treatment System ndash Assessment Plan and Report
Item
Column 1 OperatingParameter
Column 2
Measurement Location
Column 3
Measurement Procedure
1
Concentration of dissolved total reduced sulphur (TRS) compounds
Inlet to primary treatment
1 Measure the parameter in Column 1 on threeconsecutive days
2 On each day the measurement required byparagraph 1 shall be performed by taking atleast two grab samples during daylight hours
3 There shall be at least five hours between thegrab samples taken in paragraph 2
4 Analyse each grab sample to determine thevalue of the parameter in Column 1 in eachgrab sample
5 Calculate the average value for the parameterin Column 1 by averaging all of the valuesdetermined in paragraph 4
6 The analysis required by paragraph 4 shallidentify the concentration of methylmercaptan dimethyl disulphide dimethylsulphide and total dissolved sulphide
For wastewater by-passing the primary treatment the point where the wastewater discharges from the bypass to the aerated stabilization system
1 Measure the parameter in Column 1 on threeconsecutive days
2 On each day the measurement required byparagraph 1 shall be performed by taking atleast one grab sample during daylight hours
3 Analyse each grab sample to determine thevalue of the parameter in Column 1 in eachgrab sample
4 Calculate the average value for the parameterin Column 1 by averaging all of the valuesdetermined in paragraph 3
5 The analysis required by paragraph 3 shallidentify the concentration of methylmercaptan dimethyl disulphide dimethylsulphide and total dissolved sulphide
The point of discharge from primary treatment to the aerated stabilization basin system
Exit of each aerated stabilization basin cell
At least one point in each aerated stabilization basin cell The point must be representative of the range of total reduced sulphur (TRS) compounds concentrations in the aerated stabilization basin cell No point shall be in close proximity to an aerator
2 Concentration of dissolved oxygen
Exit of each aerated stabilization basin cell that contains an aerator
1 Measure the parameter in Column 1 on threeconsecutive days
2 On each day the measurement required byparagraph 1 shall be performed by taking atleast one grab sample or using in-situ testingwith a luminescent probe
3 The measurements described in paragraph 2shall be taken during daylight hours
4 Analyse each grab sample and probe result todetermine the value of the parameter inColumn 1
5 Calculate the average value for the parameterin Column 1 by averaging all of the valuesdetermined in paragraph 4
At least one point in each aerated stabilization basin cell The point must be representative of the range of dissolved oxygen concentrations in the aerated stabilization basin cell No point shall be in close proximity to an aerator
127Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item
Column 1 OperatingParameter
Column 2
Measurement Location
Column 3
Measurement Procedure
3 pH
Inlet to primary treatment
1 Measure the parameter in Column 1continuously during the period of assessmentmentioned in subsection (3)
2 Calculate an average value for the parameterin Column 1 by averaging the valuesdetermined in paragraph 1 at least one time inevery five-minute period
3 Calculate the average value for the parameterin Column 1 by averaging all of the valuesdetermined in paragraph 2
For any wastewater by-passing the primary treatment the point where the wastewater discharges from the bypass to the aerated stabilization system
Either of the following measurement procedures
1 A daily grab sample taken each day in athree-day period
2 Use of a probe to obtain an in-situmeasurement taken each day in a three-dayperiod
The point of discharge from primary treatment to the aerated stabilization basin system
At least one point in each aerated stabilization basin cell The point must be representative of the range of pH concentrations in the aerated stabilization basin cell No point shall be in close proximity to an aerator
4 Temperature
Inlet to primary treatment
Either of the following measurement procedures
1 A daily grab sample taken each day for threedays
2 Use of a probe to obtain an in-situ measurement taken each day in a three-day period
For any wastewater by-passing the primary treatment the point where the wastewater discharges from the bypass to the aerated stabilization system
The point of discharge from primary treatment to the aerated stabilization basin system
At least one point in the aerated stabilization basin cell The point must be representative of the range of temperature in the aerated stabilization basin cell No point shall be in close proximity to an aerator
128Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item
Column 1 OperatingParameter
Column 2
Measurement Location
Column 3
Measurement Procedure
5 Concentration of BOD5 (total and soluble)
Inlet to primary treatment
1 Measure the parameter in Column 1 on threeconsecutive days
2 On each day the measurement required byparagraph 1 shall be performed by takingsamples at least every 20 minutes duringdaylight hours
3 The sample mentioned in paragraph 2 shallbe obtained by taking fixed volume grabsamples or by using a composite sampler
4 On each day the samples required byparagraph 2 shall be combined to form a dailycomposite sample
5 Analyse each daily composite sample todetermine the value of the parameter inColumn 1 for each daily composite sample
6 The analysis required by paragraph 5 shallinclude the incubation of the daily compositesample for 5 days at 20degC
7 Calculate the average value for the parameterin Column 1 by averaging all of the values determined in paragraph 5
8 The parameter in Column 1 shall beexpressed in mg of oxygen consumed per Lof sample
For any wastewater by-passing the primary treatment the point where the wastewater discharges from the bypass to the aerated stabilization system
1 Measure the parameter in Column 1 on threeconsecutive days
2 On each day the measurements required byparagraph 1 shall be performed by taking atleast one grab sample during daylight hours
3 Analyse each grab sample to determine thevalue of the parameter in Column 1 in eachgrab sample
4 Calculate the average value for the parameterin Column 1 by averaging all of the valuesdetermined in paragraph 3
5 The analysis required by paragraph 3 shallinclude the incubation of the grab sample for5 days at 20degC
6 The parameter in Column 1 shall beexpressed in mg of oxygen consumed per Lof sample
The point of discharge from primary treatment to the aerated stabilization basin system
The exit of each aerated stabilization basin cell
Outlet of the wastewater treatment system
6 BOD5 loading rate
The point of discharge from primary treatment to the aerated stabilization basin system
For each location set out in Column 2 calculate the parameter in Column 1 by multiplying the concentration measured in Item 5 of this Table for the corresponding location by the flow rate measured in Item 9 of this Table The exit of each aerated
stabilization basin cell
7 Historical frequency of dredging
Primary settling basin List the dates on which the basin was dredged in the last five years
Each aerated stabilization basin cell List the dates on which each cell was dredged in the last 20 years
129Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
OperatingParameter
Column 2
Measurement Location
Column 3
Measurement Procedure
8 Hydraulic retention time Aerated stabilization basin system -shy
9 Wastewater flow rate
Outlet of wastewater treatment system
1 Measure the parameter in Column 1continuously during the period of assessmentmentioned in subsection (3) by using acontinuous flow meter
2 Calculate an average value for the parameterin Column 1 by averaging the valuesdetermined in paragraph 1 at least one time inevery one-hour period
3 Calculate the average value for the parameterin Column 1 by averaging all of the valuesdetermined in paragraph 2
10 Aeration potential Each aerated stabilization basin cell
1 Count the number of aerators installed
2 Count the number of aerators in use
3 Calculate the energy input or aeration rate ofeach aerator in use
Wastewater Treatment System ndash Optimization Report amp Implementation 47 (1) Subject to subsection (5) the owner and operator of a pulp and paper facility that
uses the kraft process and that has an aerated stabilization basin shall ensure that a report isprepared that contains the following information
1 Using the information set out in the report required by subsection 46 (5) the results of apredictive model that determines the daily emission rate of total reduced sulphur (TRS)compounds discharged into the air for the wastewater treatment system
2 All operating scenarios that would reduce the emission rate determined under paragraph1
3 For each operating scenario set out under paragraph 2 a range of values for eachoperating parameter identified in clause (a) of subsection 46 (1) that is related to theoperating scenario
4 For each operating scenario set out under paragraph 2 the results of a predictive modelthat determines the daily emission rate of total reduced sulphur (TRS) compoundsdischarged into the air for the wastewater treatment system
5 Using the results from the predictive modelling required by paragraph 4 a ranking of theoperating scenarios set out under paragraph 2 based on the effectiveness of the scenarioto prevent or minimize the discharge of total reduced sulphur (TRS) compounds into theair from the wastewater treatment system
(2) The owner and operator shall ensure that at least one of the operating scenariosdetermined under subsection (1) is identified as an action under subsection 14 (1) and thatprocedures to implement the action are developed under subsection 14 (3)
(3) The operating scenarios mentioned in subsection (2) shall include the highest rankedoperating scenario under paragraph 5 of subsection (1) that is feasible to implement at thefacility
(4) For each operating scenario that is determined not to be feasible for the purposes ofsubsection (3) the report required by subsection (1) shall include
(a) an explanation of why the operating scenario is not feasible and
130Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(b) the next highest ranked operating scenario under paragraph 5 of subsection (1) that isfeasible to implement at the facility
(5) If the date of application for registration in respect of the facility mentioned in subsection(1) is on or before March 31 2015 this section does not apply to the facility for the six-monthperiod following the date of registration
Wastewater Treatment System Assessment and Optimization Update 48 (1) The owner and operator of a pulp and paper facility that uses the kraft process shall
ensure that the reports required by subsections 46 (5) and 47 (1) are updated in accordancewith this section
(2) Subject to subsection (7) the reports required by subsections 46 (5) and 47 (1) shall beupdated if
(a) notice is required to be given under subsection 12 (1) of a contravention of section 5 or 6and
(b) the procedure required to be implemented under subsection 13 (1) is one of theprocedures mentioned in subsection 47 (2)
(3) The update required by subsection (2) shall be completed no later than six months afterthe last date specified in paragraph 2 of subsection 12 (3) and shall at minimum includeupdating the information required by section 47
(4) Subject to subsection (5) at least one time in every 10-year period all of the information inthe reports required by subsections 46 (5) and 47 (1) shall be updated
(5) The Director may give written notice to the person mentioned in subsection (1) indicatingthat subsection (4) does not apply to the person for a specified 10-year period if the personrequests the notice in writing no later than the first day of the tenth year in the 10-year periodand no earlier than the first day of the ninth year in the 10-year period and
(a) the person has not been given a notice under this section with respect to the previous 10shyyear period and at the time that the request is made a procedure under subsection 47 (2)is being implemented at the facility or
(b) in the two-year period preceding the date of the request no notice has been required tobe given under subsection 12 (1) of a contravention of section 5 or 6 and the Director is ofthe opinion that it is not necessary to identify additional operating scenarios underparagraph 2 of subsection 47 (1)
(6) In considering a request made under clause (a) of subsection (5) the Director mayconsider the number of previous requests made under subsection (5)
(7) This section does not apply if the facility mentioned in subsection (1) is an existing facilityand the date is before July 1 2015
PART V ndash MONITORING
In-Facility Monitoring 49 (1) The owner and operator of a pulp and paper facility shall ensure that measurements
are taken and recorded in accordance with this section (2) Subject to subsection (3) for each technology listed in Column 1 of Table 4 - 4 9 that
is associated with a registered contaminant the parameters set out in Column 2 of Table 4-49shall be measured at the locations set out opposite the parameter in Column 3 with the frequency set out in Column 4
(3) If in accordance with subsection 35 (4) Item 4 of the Parameter Summary Table refers tothe parameter of Corona Power Input Item 5 of 4-49Table shall be set out as follows
Column 2 Voltage (V) Current (I)
131Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Column 3 A location that would allow measurement of voltage and current from each field
Column 4 Continuously Column 5 Calculate Vav and Iav averaged over a one-hour period Calculate Corona Power Input = sum (Vav Iav) for each field
(4) If for the purpose of subsection 35 (1) a parameter was set out in the ParameterSummary Table with respect to Item 10 of Table 4 - 3 5 the parameter shall be measured at a location and in a manner consistent with the recommendations made by a professional
(5) The measurement locations of pH for the purposes of Item 2 of Table 4-49 shall berecorded
(6) The results of the measurements required under subsection (2) and (4) shall be recordedand used to determine the calculated parameter in Column 5 of Table 4-49
(7) For each parameter required to be measured under subsections (2) and (4) a writtenprocedure that will result in an accurate measurement shall be developed
(8) If having regard to subsection (3) opacity is required to be measured for the purpose ofItem 5 of Table 4-49 the measurement shall be performed by a device installed in accordance with the document entitled ldquoProtocols and Performance Specifications for Continuous Monitoring of Gaseous Emissions from Thermal Power Generationrdquo (Report EPS 1PG7 December 2005) published by Environment Canada as amended from time to time and operated in accordance with the manufacturerrsquos recommendations
(9) A measurements required by Item 3 of Table 4-49 and a measurement ofconcentration required by Item 7 of Table 4-49 shall be performed in accordance with a plan approved by the Director
(10) If the Director has reasonable grounds to believe that a measurement required to betaken in subsection (2) or (4) is inaccurate the Director may give written notice to the ownerand operator of a pulp and paper facility requiring the use in accordance with the notice of
(a) a specified type of monitor(b) procedures to be followed when taking the measurement and(c) a specified method of analysis of the measurement(11) Before the Director gives a person notice under subsection (10) the Director shall give
the person a draft of the notice and an opportunity to make written submissions to the Directorduring the period that ends 30 days after the draft is given
Table 4-49 In-Facility Monitoring
Item Column 1
Technology
Column 2 Measured Parameter
Column 3 Measurement Location
Column 4 Measurement Frequency
Column 5 Calculated Parameter
1 Wet scrubber
Scrubbing liquid flow rate
Pressure
Inlet to the scrubber
1 Inlet to thescrubber
Continuously
Continuously
Average flow rate calculated at least one time in every five-minute period
1 Averagepressure (Pavg)calculated atleast one time inevery five-minuteperiod
132Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Technology
Column 2 Measured Parameter
Column 3 Measurement Location
Column 4 Measurement Frequency
Column 5 Calculated Parameter
2 Outlet of the 2 Pressurescrubber Differential =
Pavgoutlet ndashPavginlet
2 Wet scrubber ndash with alkalinesolution
Scrubbing liquid flow rate
1 Inlet to thescrubber Continuously
Average flow rate calculated at least one time in every five-minute period
Pressure
1 Inlet to thescrubber
2 Outlet of thescrubber
Continuously
1 Averagepressure (Pavg)calculated atleast one time inevery five-minuteperiod
2 PressureDifferential =Pavgoutlet ndashPavginlet
pH of scrubbing liquid
At least one of
1 Inlet to thescrubber
2 Outlet of thescrubber
3 The scrubberrecirculation line
Continuously
Average pH calculated at least one time in every five-minute period
3
Wet scrubber ndash with alkalinesolution at a bleach plant
Concentration of chlorine dioxide (ppm)
1 Inlet of thescrubber
2 Outlet of thescrubber
At least one time in every 12-month period
Per cent removal of chlorine dioxide = [1 ndash ( CoutletCinlet)]
4 Thermal oxidizer Temperature
At the point that represents a residence time of 075 seconds
Continuously
Average temperature calculated at least one time in every five-minute period
5 Electrostatic precipitator Opacity
Immediately before the outlet of the stack of
Continuously Average opacity calculated at least one time in
133Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Technology
Column 2 Measured Parameter
Column 3 Measurement Location
Column 4 Measurement Frequency
Column 5 Calculated Parameter
the electrostatic precipitator
every one-minute period
6 Lime kiln
Percentage of flue gas that is oxygen Outlet of the kiln Continuously
Average percentage oxygen calculated at least one time in every five-minute period
Percentage of sodium in lime mud
Kiln feed from the lime mud filter
Continuously or at least one grab sample per day
Mass flow rate of steam
Steam inlet to steam stripper
1 Average massflow rate of steam(Flow-avgteam)calculated atleast one time inevery five-minuteperiod
Mass flow rate of process condensate
Condensate inlet to steam stripper
Continuously
2 Average massflow rate ofprocesscondensate(Flowshyavgcondensate)calculated at
7 Steam stripper
least one time inevery five-minuteperiod
3 Steam-to-CondensateRatio = Flowshyavgsteam Flowshyavgcondensate
Concentration of total reduced sulphur (TRS) compounds
1 Inlet of thesteam stripper
2 Outlet of thesteam stripper
At least one time in every 12-month period
Per cent removal of TRS = [1 ndash ( CoutletCinlet)]
Concentration of 1 Inlet of the At least one time in Per cent removal
134Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Technology
Column 2 Measured Parameter
Column 3 Measurement Location
Column 4 Measurement Frequency
Column 5 Calculated Parameter
methanol steam stripper
2 Outlet of thesteam stripper
every 12-month period of methanol = [1 ndash ( CoutletCinlet)]
8
Recovery boiler Percentage solids
that is in black liquor
Black liquor feed at a point immediately before entering the boiler
Continuously
Average percentage solids the is in black liquor calculated at least one time in every five-minute period
9 Aerated stabilization basin system
pH Inlet to aerated stabilization basin system
Continuously
Average pH calculated at least one time in every five-minute period
Dissolved oxygen (DO)
Outlet of each aerated stabilization basin that contains an aerator
At least one grab sample taken during daylight hours every weekday
10
Wastewater treatment system
1 Concentration oftotal reducedsulphur (TRS)compoundsmeasured in amanner that alsoidentifies theconcentration ofhydrogen sulphide
Inlet to primary treatment
At least one grab sample taken at least one time in every 3shymonth period during daylight hours including the second Tuesday of every 3shymonth period unless the Director specifies another date in writing
Daily TRS Loading = CTRS Flow Daily Production Rate
Daily H2 S Loading =
CH2S Flow Daily Production Rate
2 Flow rate of thewastewater
At the time the concentrations in paragraph 1 of this Item were measured
3 Daily ProductionRate
On the day that the concentrations in paragraph 1 of this Item were measured
pH Inlet to primary treatment Continuously Average pH
calculated at
135Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Technology
Column 2 Measured Parameter
Column 3 Measurement Location
Column 4 Measurement Frequency
Column 5 Calculated Parameter
least one time in every five-minute period
Ambient Monitoring 50 (1) The owner and operator of a pulp and paper facility that uses the kraft process shall
ensure that (a) the concentration of total reduced sulphur (TRS) compounds discharged into the air from
facility is effectively measured by one or more community ambient monitors that havebeen identified by the Director under subsection (5) and
(b) the concentration of total reduced sulphur (TRS) compounds discharged into the air fromthe wastewater treatment system is effectively measured by one or more wastewaterambient monitors that have been identified by the Director under subsection (5)
(2) Each ambient monitor mentioned in subsection (1) shall(a) measure and record the concentration of total reduced sulphur (TRS) compounds in the
air every minute(b) meet the applicable requirements set out in the Operations Manual for Air Quality
Monitoring in Ontario PIBS 6687e as amended from time to time and(c) if the monitor is a community ambient monitor be located at a point that is not on the
property of the facility(3) The person mentioned in subsection (1) shall ensure that each ambient monitor identified
by the Director under subsection (5) effectively measures the concentration of total reducedsulphur (TRS) compounds discharged into the air
(4) The person mentioned in subsection (1) shall ensure that a diagram drawn to scale thataccurately depicts the location of all ambient monitors related to the facility including all community ambient monitors and wastewater ambient monitors is submitted to the Director
(5) The Director may identify in writing which ambient monitors depicted in the diagramsubmitted for the purpose of subsection (4) or (9) are in the opinion of the Director adequate toeffectively measure the concentration of total reduced sulphur (TRS) compounds dischargedinto the air
(6) If the Director is of the opinion that an ambient monitor depicted in the diagram submittedfor the purpose of subsection (4) or (9) is not adequate to effectively measure the concentrationof total reduced sulphur (TRS) compounds discharged into the air the Director may give writtennotice to the person mentioned in subsection (1) requiring steps to be taken in accordance withthe notice including one or more of the following steps
1 Relocate one or more ambient monitors2 Install an additional ambient monitor(7) Before the Director gives a person a notice under subsection (6) the Director shall give
the person a draft of the notice and an opportunity to make written submissions to the Directorduring the period that ends 30 days after the draft is given
(8) The Director may indicate in writing that an ambient monitor is no longer identified forthe purpose of subsection (5) if
(a) the Director is of the opinion that the ambient monitor is not necessary to effectivelymeasure the concentration of total reduced sulphur (TRS) compounds discharged into theair
(b) at least one community ambient monitor remains identified under subsection (5) and(c) at least one wastewater ambient monitor remains identified under subsection (5)
136Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(9) If there is a change to any of the information contained in the diagram required bysubsection (4) the person mentioned in subsection (1) shall ensure that the diagram is updatedand the updated diagram is submitted to the Director no later than 30 days after the change occurs
Baseline TRS Monitoring Data ndash Wastewater 51 (1) The owner and operator of a pulp and paper facility that uses the kraft process shall
ensure that a baseline is determined in accordance with this section (2) No later than March 31 in the year following the first full calendar year in which this
section applies in respect of the facility mentioned in subsection (1) a baseline shall be determined by performing the following steps with respect to each wastewater ambient monitoridentified as adequate under section 50
1 For each day in the previous calendar year record one of the followingi if the monitor indicates a measurement of a concentration of total reduced sulphur
(TRS) compounds use all of the measurements from the day to calculate and recordthe daily average concentration of total reduced sulphur (TRS) compounds and
ii if the monitor indicates that all measurements of the concentration of total reducedsulphur (TRS) compounds for the day were below the detection limit of the monitorrecord half of the detection limit of the monitor as the daily average concentration oftotal reduced sulphur (TRS) compounds
iii if the monitor provides no indication of any measurements with respect to theconcentration of total reduced sulphur (TRS) compound for the day do not record adaily average concentration but instead record an explanation of why nomeasurements of total reduced sulphur (TRS) compound were taken
2 Translate each daily average calculated in paragraph 1 to its equivalent natural logarithm3 Calculate the mean of all of the values translated in paragraph 24 Calculate the square of the standard deviation of all of the values translated in paragraph
2 using the following equation
Where
S is the standard deviation
m is the number of daily average concentrations recorded in paragraph 1
xi is each value translated in paragraph 2 and
X is the value calculated in paragraph 3 (3) Subject to subsection (4) no later than March 31 in the year following the first full
calendar year after an operating scenario determined under subsection 47 (1) has beenimplemented at the facility the baseline mentioned in subsection (1) shall be re-determined byperforming the steps set out in subsection (2) using concentrations of total reduced sulphur(TRS) compounds measured by the monitor in the previous calendar year
(4) Subsection (3) does not apply if the concentration of total reduced sulphur (TRS)compounds measured by the monitor averaged over the calendar year mentioned in subsection(3) is higher than
137Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(a) if no re-determination has previously been made under subsection (3) the concentrationof total reduced sulphur (TRS) compounds measured by the monitor averaged over thecalendar year mentioned in subsection (2) or
(b) if a re-determination has previously been made under subsection (3) the concentration oftotal reduced sulphur (TRS) compounds measured by the monitor averaged over thecalendar year associated with the most recent re-determination under subsection (3)
(5) The results of each step required to be performed under subsection (2) shall be recorded
Statistical Analysis of TRS Concentration from Wastewater Monitor 52 (1) For the purpose of this section reference to a statistically significant increase in the
concentration of total reduced sulphur (TRS) compounds is a reference to the determination ofwhether the concentration of total reduced sulphur (TRS) compounds measured at a monitorduring a calendar year is higher than the concentration of total reduced sulphur (TRS)compounds measured at the monitor during the year in which the most recent baseline wasdetermined under section 51 and if so whether the increase in concentration is statisticallysignificant
(2) The owner and operator of a pulp and paper facility that uses the kraft process shallensure that a determination of whether a statistically significant increase in the concentration oftotal reduced sulphur (TRS) compounds has occurred in a year is made in accordance with thissection
(3) No later than March 31 in each year following the second full calendar year in which thissection applies in respect of the facility mentioned in subsection (2) a statistical analysis shallbe completed by performing the following steps with respect to each wastewater ambient monitor identified as adequate under section 50
1 For each day in the previous calendar year record one of the followingi if the monitor indicates a measurement of a concentration of total reduced sulphur
(TRS) compounds use all of the measurements from the day to calculate and recordthe daily average concentration of total reduced sulphur (TRS) compounds and
ii if the monitor indicates that all measurements of the concentration of total reducedsulphur (TRS) compounds for the day were below the detection limit of the monitorrecord half of the detection limit of the monitor as the daily average concentration oftotal reduced sulphur (TRS) compounds
iii if the monitor provides no indication of any measurements with respect to theconcentration of total reduced sulphur (TRS) compound for the day do not record adaily average concentration but instead record an explanation of why nomeasurements of total reduced sulphur (TRS) compound were taken
2 Translate each daily average calculated in paragraph 1 to its equivalent natural logarithm3 Calculate the mean of all of the values translated in paragraph 24 Calculate the square of the standard deviation of all of the values translated in paragraph
2 using the following equation
Where
S is the standard deviation
n is the number of daily average concentrations recorded in paragraph 1
138Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
xi is each value translated in paragraph 2 and
X is the value calculated in paragraph 3
5 Calculate the test statistic using the following equation
Where
T is the test statistic
Y is the value calculated in paragraph 3
X is the most recent value calculated in paragraph 3 of subsection 51 (2)
S1 is the most recent value calculated in paragraph 4 of subsection 51 (2)
S2 is the value calculated in paragraph 4
m is the most recent number of values calculated in paragraph 1 of subsection 51 (2) and
n is the number of values calculated in paragraph 1
6 Calculate the degrees of freedom using the following equation
Where
(v) is the degrees of freedom and
S1 S2 m and n have the same meanings as set out in paragraph 5
7 Find the value calculated in paragraph 6 in Column 1 of Table 4 - 5 2 and determinethe value set out opposite that value in Column 2
8 Determine whether there has been a statistically significant increase in the concentrationof total reduced sulphur (TRS) compounds at the monitor by assessing whether the valuecalculated in paragraph 5 exceeds the value determined under paragraph 7
(4) If the value calculated in paragraph 5 of subsection (3) exceeds the value determinedunder paragraph 7 of subsection (3) the Director may upon the written request of the personmentioned in subsection (2) give written notice to the person indicating that one or more of thefollowing steps may be performed in accordance with the notice to determine whether therehas been a statistically significant increase in the concentration of total reduced sulphur (TRS)compounds at the monitor
1 Re-perform the steps set out in subsection (3) and when calculating each daily averageconcentration of total reduced sulphur (TRS) compounds under paragraph 1 of subsection(3) exclude concentrations that were measured when the wind was blowing from a
139Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
direction that did not pass over the wastewater treatment system before reaching themonitor
2 When making the determination under paragraph 8 of subsection (3) use a statisticalmethod other than the method set out in paragraphs 2 to 7 of subsection (3) if theDirector is of the opinion that
i the values translated under paragraph 2 of subsection (3) are not normally distributedand
ii the other method would more accurately determine whether there has been astatistically significant increase in the concentration of total reduced sulphur (TRS)compounds at the monitor
(5) A request for a notice under subsection (4) shall be made no later than March 1 of theyear and shall contain the following information
1 The statistical analysis performed in accordance with subsection (3)2 If the request pertains to the step described in paragraph 1 of subsection (4)
i all relevant information regarding wind direction including wind directionmeasurements taken by an anemometer located and operated in accordance with theOperations Manual for Air Quality Monitoring in Ontario PIBS 6687e as amendedfrom time to time and
ii for each concentration that is proposed to be excluded an indication of the cause ofthe measurement and a justification for the exclusion of the measurement
3 If the request pertains to the step described in paragraph 2 of subsection (4)i a description of the statistical method proposed to be usedii an explanation of why the proposed statistical method would more accurately
determine whether there has been a statistically significant increase in theconcentration of total reduced sulphur (TRS) compounds at the monitor than thestatistical method set out in subsection (3) and
iii the statistical analysis performed in accordance with the proposed statistical method(6) If it is determined that there has been a statistically significant increase in the
concentration of total reduced sulphur (TRS) compounds at the monitor the person mentionedin subsection (2) may submit in writing the following information to the Director
1 Information indicating that the statistically significant increase in the concentration of totalreduced sulphur (TRS) compounds at the monitor for the previous calendar year iscaused by a source of contaminant other than the wastewater treatment system
2 A plan that will prevent or minimize discharges of total reduced sulphur (TRS) compoundsinto the air from each source of contaminant mentioned in paragraph 1
3 Dates by which the plan mentioned in paragraph 2 will be implemented(7) The information mentioned in subsection (6) shall be submitted by the following date1 If no notice has been given under subsection (4) in respect of the previous calendar year
March 1 of the year2 If a notice has been given under subsection (4) in respect of the previous calendar year
no later than 30 days after the date the notice was given(8) If the Director is of the opinion that the information submitted under subsection (6)
demonstrates that the statistically significant increase in the concentration of total reduced sulphur (TRS) compounds at the monitor is caused by a source of contaminant other than thewastewater treatment system he or she may give a written notice to the person mentioned insubsection (2) indicating that subsection 6 (1) does not apply in respect of the statistically significant increase
(9) The results of each step performed for the purpose of this section shall be recorded
140Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Table 4-52 Statistical Analysis of TRS Concentration from Wastewater Monitor
Item Column 1 Column 2
Degrees of Freedom (v) Test Statistic (T) with level of significance () = 00005
1 1 6366
2 2 3160
3 3 1292
4 4 8610
5 5 6869
6 6 5959
7 7 5408
8 8 5041
9 9 4781
10 10 4587
11 11 4437
12 12 4318
13 13 4221
14 14 4141
15 15 4073
16 16 4015
17 17 3965
18 18 3922
19 19 3883
20 20 3850
21 21 3819
22 22 3792
23 23 3768
24 24 3745
25 25 3725
26 26 3707
141Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1 Column 2
Degrees of Freedom (v) Test Statistic (T) with level of significance () = 00005
27 27 3690
28 28 3674
29 29 3659
30 30 3646
31 40 3551
32 60 3460
33 120 3373
34 infin 3291
Large Wood-fired Combustor - Continuous Monitoring ndash Nitrogen Oxides 53 (1) The owner and operator of a pulp and paper facility that has a new large wood-fired
combustor with a heat input capacity of at least 100 MW shall ensure that the concentration ofnitrogen oxides in the flue gas of the combustor is measured with a continuous emissionsmonitoring system at a point approved by the Director
(2) The point of measurement mentioned in subsection (1) shall be a point between(a) the exit of the furnace and(b) a point immediately before the flue gas is discharged into the air(3) For further certainty if a large wood-fired combustor is attached to an air pollution control
device the flue gas is discharged into the air when it exits the air pollution control device(4) The measurements required by subsection (1) shall be recorded at least every 15
minutes (5) The person mentioned in subsection (1) shall ensure that the continuous emissions
monitoring system is selected installed in accordance with the document entitled ldquoProtocols and Performance Specifications for Continuous Monitoring of Gaseous Emissions from ThermalPower Generationrdquo (Report EPS 1PG7 December 2005) published by Environment Canada as amended from time to time and operated in accordance with the manufacturerrsquos recommendations
Large Wood-fired Combustor - Continuous Monitoring ndash Carbon Monoxide Oxygen andTemperature
54 (1) Subject to subsection (5) the owner and operator of a pulp and paper facility that hasa large wood-fired combustor shall ensure that the following parameters in the flue gas of thecombustor are measured with a continuous emissions monitoring system at a point approvedby the Director
1 The percentage of the flue gas that is oxygen2 The concentration of carbon monoxide3 Temperature(2) The point of measurement mentioned in subsection (1) shall be a point between(a) the exit of the furnace and(b) the exit of the large wood-fired combustor
142Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(3) The measurements mentioned in subsection (1) shall be recorded at least every 15minutes
(4) The person mentioned in subsection (1) shall ensure that the continuous emissionsmonitoring system is selected installed in accordance with the document entitled ldquoProtocols and Performance Specifications for Continuous Monitoring of Gaseous Emissions from ThermalPower Generationrdquo (Report EPS 1PG7 December 2005) published by Environment Canada as amended from time to time and operated in accordance with the manufacturerrsquos recommendations
(5) This section does not apply to an existing large wood-fired combustor before July 1 2016
Large Wood-fired Combustor - In-Stack Concentration Testing ndash After CommissioningPeriod
55 (1) The owner and operator of a pulp and paper facility that has a new or significantlymodified large wood-fired combustor shall ensure that no later than 12 months after the end ofthe commissioning period the flue gas of the combustor is tested to measure the concentrationof the following contaminants
1 The filterable portion of suspended particulate matter2 Benzo(a)pyrene3 Dioxins furans and dioxin-like PCBs reported as toxic equivalency4 All metals that may be present in the fuel(2) The measurements required by subsection (1) shall be made in accordance with section
57
Large Wood-fired Combustor - Periodic In-Stack Concentration Testing 56 (1) Subject to subsection (2) the owner and operator of a pulp and paper facility that has
a large wood-fired combustor shall ensure that at least once in a 12-month period the flue gasof the large wood-fired combustor is tested to measure the concentration of the following contaminants
1 The filterable portion of suspended particulate matter2 Benzo(a)pyrene3 Dioxins furans and dioxin-like PCBs reported as toxic equivalency4 All metals that may be present in the wood(2) Subsection (1) does not apply to a large wood-fired combustor that does not burn
municipal waste other than woodwaste if the person mentioned in subsection (1) ensures thatat least once in a four-year period the flue gas of the combustor is tested to measure theconcentration of the filterable portion of suspended particulate matter and benzo(a)pyrene
(3) The measurements required by subsections (1) and (2) shall be made in accordance withsection 57
(4) If the Director has reasonable grounds to believe that discharges of a contaminantmentioned in subsection (1) into the air from a large wood-fired combustor may be causing anadverse effect the Director may give written notice to the person required to perform themeasurements required by subsection (1) and (2) requiring the person to take measurementsin accordance with the notice at such regular intervals that may be specified by the Director
(5) Before the Director gives a person notice under subsection (4) the Director shall give theperson a draft of the notice and an opportunity to make written submissions to the Directorduring the period that ends 30 days after the draft is given
Large Wood-fired Combustor - In-Stack Testing Approval 57 (1) The measurements required in sections 55 and 56 shall be obtained by performing
the following steps
143Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
1 Submit a stack-testing plan to the Director for approval at least 120 days before themeasurements are proposed to be taken
2 After receiving approval of the plan mentioned in paragraph 1 provide written notice to theDirector at least 30 days before the measurements are taken
3 Provide an opportunity for representatives of the Ministry to witness the taking of themeasurements
4 No later than four months after the measurements are taken submit the measurements tothe Director for approval as being an accurate reflection of concentrations of contaminantsmeasured
(2) Subject to subsection (3) the plan mentioned in paragraph 1 of subsection (1) shallensure that the measurements are taken
(a) comprehensively and across a range of operating conditions(b) if the large wood-fired combustor is attached to an air pollution control device at a point
that is downstream of the device and that is immediately before the gas is discharged intothe air
(c) if the large wood-fired combustor is not attached to an air pollution control device at apoint that is immediately before the gas is discharged into the air and
(d) at least three separate times and that an average concentration is calculated from themeasurements
(3) The Director may deem a plan to meet the requirements of subsection (2) if in theopinion of the Director the plan sets out an alternate method of taking measurements that willresult in an accurate reflection of concentrations of contaminants measured
PART VI ndash RECORDS AND REPORTING
Complaint Procedure 58 (1) The owner and operator of a pulp and paper facility shall ensure that the following
steps are taken to properly respond to each complaint that relates to the discharge of a contaminant into the air from the facility
1 A prompt response is made to the person who made the complaint if a response isrequested by the person
2 Action is taken to remedy the cause of the complaint3 A written record of the complaint is prepared that includes the following information
i a description of the complaintii the date and time that the complaint was receivediii the date time and suspected cause of the incident to which the complaint relatesiv ambient temperature at the time of the incident to which the complaint relates if
relevantv the approximate wind direction and wind speed at the time of the incident to which the
complaint relates if relevantvi the general weather conditions at the time of the incident to which the complaint
relates if relevant andvii a description of any actions taken to address the incident to which the complaint
relates and the date each action was completed
144Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(2) If a complaint is made that relates to a matter addressed in this industry standard theowner and operator of a pulp and paper facility shall ensure that a provincial officer is notified ofthe complaint as soon as practicable after the complaint is made
(3) No later than five days after a notice is required to be given under subsection (2) theowner and operator shall ensure that the following information is submitted in writing to aprovincial officer
1 A description of the complaint2 The time and date of the incident to which the complaint relates3 A description of any actions taken or that will be taken to address the incident to which
the complaint relates4 The dates on which the actions mentioned in paragraph 3 were completed or are
anticipated to be completed
Removal Efficiency Report ndash Steam Stripper 59 (1) No later than March 31 in each year following the first full calendar year in which this
section applies in respect of a pulp and paper facility that uses the kraft process the owner andoperator of the facility shall ensure that a report entitled ldquoRemoval Efficiency Report - Steam Stripperrdquo is prepared that sets out the following information with respect to the concentration oftotal reduced sulphur (TRS) compounds measured in accordance with Item 7 of Table 4-49 1 The concentration of total reduced sulphur (TRS) compounds measured at the inlet
2 The concentration of total reduced sulphur (TRS) compounds measured at the outlet3 The per cent removal of total reduced sulphur (TRS) compounds4 The date that each measurement mentioned in paragraphs 1 and 2 was taken(2) The report mentioned in subsection (1) shall also set out the information required by
subsection (1) with necessary modifications as it pertains to the concentration of methanolmeasured in accordance with Item 7 of Table 4-49
Removal Efficiency Report ndash Chlorine Dioxide Scrubber 60 No later than March 31 in each year following the first full calendar year in which this
section applies in respect of a pulp and paper facility that uses the kraft process the owner andoperator of the facility shall ensure that a report entitled ldquoRemoval Efficiency Report - ChlorineDioxide Scrubberrdquo is prepared that sets out the following information with respect the to theconcentration of chlorine dioxide measured in accordance with Item 3 of Table 4-49
1 The concentration of chlorine dioxide in ppm measured at the inlet2 The concentration of chlorine dioxide in ppm measured at the outlet3 The per cent removal of chlorine dioxide4 The date that each measurement mentioned in paragraphs 1 and 2 was taken
Annual Summaries 61 (1) The owner and operator of a pulp and paper facility shall ensure that annual
summaries are prepared and reviewed in accordance with this section(2) A table entitled ldquoImplementation Summary Tablerdquo shall be prepared that sets out the
following information 1 A summary of the provisions of this industry standard that apply in accordance with
section 32 For each provision mentioned in paragraph 1
145Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
i an indication of whether the provision applies on the date of registration on a dateafter the date of registration or on a recurring basis
ii if the provision applies after the date of registration an indication of the date by whichcompliance with the provision is required
iii if compliance with the provision has been achieved an indication of the date on whichcompliance was achieved and
iv if the provision applies on a recurring basis an indication of the date on whichcompliance was last achieved and an indication of the next date by which compliancewith the provision is required
(3) A table entitled ldquoPerformance Summary Tablerdquo shall be prepared that sets out thefollowing information
1 If in accordance with section 3 one or more of sections 4 to 10 applyi the date and time of each contravention of each applicable section andii the duration of each contravention mentioned in subparagraph i
2 A description of the steps taken to address each contravention mentioned underparagraph 1 including each corrective action required to be implemented undersubsection 13 (1)
3 The Order Number of each order issued under section 15 in respect of the facility if any(4) If in accordance with section 3 one or more of the following provisions apply the
information required by the applicable provision shall be made available to the highest rankingemployee for review
1 The information regarding failure of a back-up incineration device required by subsection21 (4)
2 The information regarding the deviation of an operational parameter required bysubsection 36 (2)
3 The information regarding process loss required by subsection 38 (5)4 The measurements required by clause (a) of subsection 50 (2)5 For each parameter required to be measured under sections 53 to 56 of this industry
standardi the maximum measurementii the minimum measurement andiii the average measurement
6 The dates of each start-up or shut-down of a large wood-fired combustor in accordancewith paragraph 2 of section 11
7 A summary of any deviations from the fuel management procedures required by section26
8 A summary of the results from the most recent bi-annual adjustment required undersection 39
9 For each air pollution control device associated with a source of contaminant addressed inthis industry standard the dates when the air pollution control device did not operateduring a period when the source of contaminant was operating
10 The information regarding complaints required by subsection 58 (3)11 A summary of each notice required to be given under sections 2 17 19 21 22 33 and
3612 A summary of the removal efficiencies set out in the reports required by sections 59 and
60(5) An annual summary shall be prepared and the summary shall include at minimum the
following information 1 With respect to the events mentioned in paragraphs 1 to 3 6 8 and 9 of subsection (4)
146Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
i the number of times each of the events occurred at the facility during the calendaryear
ii an indication of whether any of the occurrences mentioned in subparagraph i were ofparticular concern
iii an assessment of whether the number of occurrences mentioned in subparagraph iindicate a recurring issue both in respect of the calendar year and in respect ofprevious calendar years and
iv an explanation of any actions taken to address the occurrences mentioned insubparagraph i
2 For each community ambient monitor identified as adequate under section 50i the number of 10-minute periods over which the average measurement of the
concentration of total reduced sulphur (TRS) compounds exceeded 27 ppb and thedate and time of each 10-minute period and
ii if the date is before July 1 2016 the number of 30-minute periods over which theaverage measurement of the concentration of total reduced sulphur (TRS)compounds exceeded 27 ppb and the date and time of each 30-minute period
3 For each wastewater ambient monitor identified as adequate under section 50 themeasurement of the concentration of total reduced sulphur (TRS) compounds averagedover
i each day of the calendar year andii the calendar year
4 The number of complaints mentioned in paragraph 10 of subsection (4) received by thefacility during the calendar year and for each complaint a description of any actions takento address the incident to which the complaint relates
5 The number of notices mentioned in paragraph 11 of subsection (4) given in respect of thefacility during the calendar year and with respect to a notice required to be given undersection 2 a summary of the information required by subsection 2 (3)
(6) The summary tables required by subsections (2) and (3) and the summary required bysubsection (5) shall be completed in hardcopy no later than March 31 each year and theinformation therein shall pertain to the preceding calendar year
(7) No later than March 31 each year the highest ranking employee at the facility shall certifyin writing that the summary tables required by subsections (2) and (3) and the summaryrequired by subsection (5) have been prepared in accordance with this industry standard andthat the information contained in the summaries is
(a) accurate and complete and(b) true to the best of his or her knowledge(8) The summary tables required by subsections (2) and (3) and the information required by
clause (a) of subsection 2 (3) shall be (a) made available for examination by any person without charge by posting it on the
Internet or by making it available during regular business hours at the place to which thereport relates and
(b) given without charge to any person within 15 days after the person requests it
Records 62 (1) Subject to subsection (2) the owner and operator of a pulp and paper facility shall
ensure that a record required to be prepared by this industry standard is retained at the facilityfor at least five years and is made available to a provincial officer or Director upon request assoon as practicable
(2) If a record mentioned in subsection (1) is a report required by sections 40 to 48 theowner and operator of a pulp and paper facility shall ensure that the report is retained for atleast five years or until an update of the report is completed whichever is later
147 Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(3) For greater certainty as set out in subsection 1 (1) every measurement result is a recordfor the purpose of this industry standard and is subject to the requirements set out in subsection(1)
(4) A person required to make a record available under subsection (1) shall make it availablein a form approved by the Director including if required by the Director an electronic formatspecified by the Director
(5) In addition to the records mentioned in subsection (1) the owner and operator of a pulpand paper facility shall ensure that each document relating to the recommendations of themanufacturer for each device at the facility with respect to the use operation and maintenanceof the device is retained for the period during which the device is used or operated
(6) If a record required to be prepared by this industry standard is required to be updated itshall contain the date that the record was first prepared and all subsequent dates upon which itwas updated
148Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
APPENDIX 4-A All Contaminants
Item CAS No Contaminant
1 75-07-0 Acetaldehyde
2 64-19-7 Acetic Acid
3 67-64-1 Acetone
4 107-02-8 Acrolein
5 7664-41-7 Ammonia
6 7440-38-2 Arsenic
7 71-43-2 Benzene
8 50-32-8 Benzo(a)pyrene [as a surrogate for total Polycyclic Aromatic Hydrocarbons (PAHs)]
9 7440-41-7 Beryllium and Beryllium compounds
10 92-52-4 Biphenyl
11 71-36-3 Butanol nshy
12 7440-43-9 Cadmium and Cadmium Compounds
13 1305-78-8 Calcium Oxide
14 124-38-9 Carbon Dioxide
15 630-08-0 Carbon Monoxide
16 56-23-5 Carbon Tetrachloride
17 7782-50-5 Chlorine
18 10049-04-4 Chlorine Dioxide
19 75-00-3 Chloroethane
20 67-66-3 Chloroform
21 7440-47-3 Chromium and Chromium Compounds
22 7440-50-8 Copper and Copper compounds
23 1319-77-3 Cresols
24 110-82-7 Cyclohexane
25 75-34-3 Dichloroethane 11shy
149Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item CAS No Contaminant
26 - Dioxins and Furans and Dioxin-like PCBs
27 100-41-4 Ethyl Benzene
28 107-06-2 Ethylene Dichloride
29 1309-37-1 Ferric Oxide
30 50-00-0 Formaldehyde
31 64-18-6 Formic Acid
32 110-54-3 Hexane nshy
33 7647-01-0 Hydrogen Chloride
34 98-82-8 Isopropyl Benzene (Cumene)
35 7439-92-1 Lead and Lead Compounds
36 1309-48-4 Magnesium Oxide
37 7439-96-5 Manganese and Manganese Compounds
38 7439-97-6 Mercury and Mercury Compounds
39 67-56-1 Methanol (Methyl Alcohol)
40 74-87-3 Methyl Chloride
41 78-93-3 Methyl Ethyl Ketone (2-Butanone)
42 108-10-1 Methyl Isobutyl Ketone
43 75-09-2 Methylene Chloride
44 91-20-3 Naphthalene
45 7440-02-0 Nickel and Nickel compounds
46 139-13-9 Nitrilotriacetic Acid
47 10102-44-0 Nitrogen Oxides
48 108-95-2 Phenol
49 123-38-6 Propionaldehyde
50 7440-22-4 Silver and Silver compounds
51 100-42-5 Styrene
52 7446-09-5 Sulphur Dioxide
150Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item CAS No Contaminant
53 7664-93-9 Sulphuric Acid
54 - Suspended Particulate Matter (lt 44 um Diameter)
55 108-88-3 Toluene
56 Total reduced sulphur (TRS) Compounds (facilities that are part of the class identified by NAICS code 3221 (Pulp Paper and Paperboard Mills)
57 79-01-6 Trichloroethylene (TCE)
58 95-63-6 Trimethylbenzene 124- (individual isomer or trimethylbenzene mixture)
59 1330-20-7 Xylenes
151Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
APPENDIX 4-B Products of Combustion ndash Large Wood-fired Combustors
Number CAS No Contaminant
1 107-02-8 Acrolein
2 50-32-8 Benzo(a)pyrene [as a surrogate for total Polycyclic Aromatic Hydrocarbons (PAHs)]
3 630-08-0 Carbon Monoxide
4 10102-44-0 Nitrogen Oxides
5 - Suspended Particulate Matter (lt 44 um Diameter)
152Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
APPENDIX 4-C Products of Combustion ndash Large Wood-fired Combustors Burning SomeMunicipal Waste
Number CAS No Contaminant
1 7440-38-2 Arsenic
2 7440-41-7 Beryllium and Beryllium compounds
3 7440-43-9 Cadmium and Cadmium Compounds
4 7440-47-3 Chromium and Chromium Compounds
5 7440-50-8 Copper and Copper compounds
6 - Dioxins and Furans and Dioxin-like PCBs
7 7647-01-0 Hydrogen Chloride
8 7439-92-1 Lead and Lead Compounds
9 7439-96-5 Manganese and Manganese Compounds
10 7439-97-6 Mercury and Mercury Compounds
11 7440-02-0 Nickel and Nickel compounds
12 7440-22-4 Silver and Silver compounds
153Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 20th 2018
APPENDIX 4-D Volatile Organic Compounds
Number CAS Number Contaminant
1 75-07-0 Acetaldehyde
2 64-19-7 Acetic Acid
3 67-64-1 Acetone
4 107-02-8 Acrolein
5 71-43-2 Benzene
6 92-52-4 Biphenyl
7 71-36-3 Butanol nshy
8 56-23-5 Carbon Tetrachloride
9 75-00-3 Chloroethane
10 67-66-3 Chloroform
11 1319-77-3 Cresols
12 110-82-7 Cyclohexane
13 75-34-3 Dichloroethane 11shy
14 100-41-4 Ethyl Benzene
15 107-06-2 Ethylene Dichloride
16 50-00-0 Formaldehyde
17 64-18-6 Formic Acid
18 110-54-3 Hexane nshy
19 98-82-8 Isopropyl Benzene (Cumene)
20 67-56-1 Methanol (Methyl Alcohol)
21 74-87-3 Methyl Chloride
22 78-93-3 Methyl Ethyl Ketone (2-Butanone)
23 108-10-1 Methyl Isobutyl Ketone
24 75-09-2 Methylene Chloride
154Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Number CAS Number Contaminant
25 108-95-2 Phenol
26 123-38-6 Propionaldehyde
27 100-42-5 Styrene
28 108-88-3 Toluene
29 79-01-6 Trichloroethylene (TCE)
30 95-63-6 Trimethylbenzene 124- (individual isomer or trimethylbenzene mixture)
31 1330-20-7 Xylenes
Record of Publications for Pulp and Paper - Industry Standard
Tracking Date Publishing Minister
Version 10
Pulp and Paper - Industry Standard
Created March 5 2014 Bradley
155Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
CHAPTER 5 - METAL FINISHERS ndash INDUSTRY STANDARD
Version 20 Created July 27 2016
Preamble
bull This technical standard is an industry standard as defined in section 1 of O Reg41905
bull With respect to facilities this industry standard applies to every facility that is part of aclass identified by NAICS code 332810 Coating Engraving Heat Treating and AlliedActivities
bull With respect to contaminants this industry standard applies to contaminants listed inAppendix 5-A
bull Each source of contaminant associated with NAICS code 332810 that discharges acontaminant mentioned in the above bullet has been considered in development of thisindustry standard As such a person that meets the criteria set out in subsection 42 (1)or subsection 44 (1) of O Reg 41905 is in general exempt from Part II of theRegulation in respect of the facility and contaminant(s) for which it is registered In otherwords there is no need to model in a facilityrsquos Emission Summary and DispersionModelling report discharges of a registered contaminant from any source ofcontaminant associated with NAICS code 332810 (For more information please see theIntroduction to the Technical Standards Publication)
bull In accordance with subsection 38 (3) of O Reg 41905 compliance with this industrystandard in accordance with subsection 42 (5) or subsection 44 (3) may reduce theregulatory burden applicable to facilities in this class
bull This standard contains requirements that relate to sources of contaminant associatedwith the following
bull decorative chromium electroplatingbull hard chromium electroplatingbull chromium anodizingbull chromium reverse etchingbull nickel electroplatingbull electroless nickel platingbull ventilation systems
bull For this industry standard with respect to chromium compounds (hexavalent) thepublication of this industry standard indicates that the following criteria of paragraph 3of subsection 38 (1) of O Reg 41905 are met
(a) with respect to at least two facilities located in Ontario to which this standardapplies it is not economically feasible to comply with section 20 of O Reg 41905
(b) compliance in accordance with subsection 42 (5) of O Reg 41905 with thisstandard
156Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(i) is technically and economically feasible with respect to at least one facility locatedin Ontario to which this industry standard applies
(ii) will permit efforts that would otherwise be made to comply with section 19 or 20of O Reg 41905 to be put to better use to protect the natural environment havingregard to clause (a) and
(iii) including this industry standard in the ldquoTechnical Standards to Manage AirPollutionrdquo is more efficient than having the Director consider separate requests undersection 32 of O Reg 41905 to set site-specific standards for the contaminant thatwould otherwise apply to facilities in the class
157Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
CONTENTS
PART I ndash GENERAL
1 Definitions2 Application
PART II - TECHNOLOGY SPECIFICATION
3 Specified technology ndash chromium compounds (hexavalent )4 Specified technologies - Nickel and nickel compounds5 Vertical and unimpeded discharges
PART III ndash OPERATION AND MAINTENANCE
6 Operating Parameter Summary Table7 Measurement of operating parameters8 Deviations from operating parameters9 Notification of deviations from operating parameters10 Phase-In for new air pollution control devices11 Inspection and Maintenance Table12 Inspection and maintenance activities13 Deviations - inspection and maintenance14 Recurring malfunctions
PART IV ndashINDUSTRIAL VENTILATION
15 Building areas to be negatively pressured16 Ventilation program17 Volumetric flow rates in and out of building areas18 Building differential pressure19 Change management - proposed changes to ventilation20 Notice - ventilation assessment report21 Commissioning of new ventilation equipment22 Multi-tenant buildings
PART V ndash REQUIREMENT TO CONTINUE THE USE OF VENTILATION SYSTEMS AND METHODS TO MANAGE EMISSIONS
23 Identifying managed sources24 Requirement to continue the management of sources25 Changes to managed sources26 Specified management of sources27 Notification of change
PART VI ndash COMPLAINTS ANNUAL SUMMARY REPORTS AND RECORDS
28 Complaint procedure29 Summary reports30 Records
APPENDIX 5-A ALL CONTAMINANTS APPENDIX 5-B CHROMIUM COMPOUNDS (HEXAVALENT) APPENDIX 5-C NICKEL AND NICKEL COMPOUNDS
158Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
PART I ndash GENERAL
Definitions 1 (1) For the purposes of this industry standard for metal finishing facilities
ldquoActrdquo means the Environmental Protection Act ldquoair pollution control devicerdquo means a device that removes contaminants from a gaseous stream
and includes packed bed scrubbers composite mesh pad scrubbers baghouses and cyclones
ldquobaghouserdquo means a device that uses fabric bags or cartridge filters to remove particulate froma gaseous stream prior to its discharge into the air
ldquobathrdquo means the solution in a tank used at a metal finishing facility for metal finishing processes such as electroplating reverse etching or anodizing
ldquoblock averagerdquo means an average of the values measured during a discrete block of time thatdoes not consider measurements before or after that time period For example a 30-minuteblock average calculated from 431 pm to 500 pm would not consider any values from401pm to 430pm
ldquobuilding differential pressurerdquo means the difference between the pressure measured inside afacility building and the pressure measured outside of the facility building
ldquocalendar weekrdquo means a seven-day period starting on Monday and ending on Sunday ldquoCAS Nordquo has the same meaning as in subsection 1 (1) of O Reg 41905 ldquochromium anodizingrdquo means the passage of an electrical current through a solution containing
one or more chromium compounds (hexavalent) in a tank connected to a rectifier in order toproduce an oxide layer on the surface of a metal or other substrate
ldquochromium electroplatingrdquo means the passage of an electrical current through a solution containing one or more chromium compounds (hexavalent) in a tank connected to a rectifierin order to produce a layer of chromium on the surface of a metal or other substrate andincludes decorative chromium electroplating and hard chromium electroplating
ldquoDistrict Managerrdquo means the District Manager of the appropriate local district office of theMinistry where the metal finishing facility is geographically located
ldquoevacuation devicerdquo means equipment that is attached to a tank cover that contains a HEPAfilter and that is used to remove any chromium compounds (hexavalent) remaining in thevolume of gas beneath the closed tank cover at the completion of the chromium electroplating chromium anodizing or reverse etching and before the tank cover is opened
ldquoexisting metal finishing facilityrdquo means a metal finishing facility (a) the construction of which was completed or began before July 1 2016 or(b) for which an application was made on or before July 1 2016 for an environmental
compliance approval in respect of the facilityldquofacility expansionrdquo means an addition or replacement of a source that discharges a registered
contaminant at a metal finishing facility after the later of January 1 2020 and the date onwhich the metal finishing facility is first registered in respect of this industry standard standardand the registered contaminant that (a) increases the total rectifier capacity of the metal finishing facility above the total rectifier
capacity of the facility as of December 31 2019 and(b) is part of one or more of the following processes
(i) decorative chromium electroplating(ii) chromium anodizing
159Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(iii) chromium reverse etching(iv) hard chromium electroplating(v) nickel electroplating(vi) electroless nickel plating
ldquofume suppressantrdquo means a compound that reduces the surface tension of a bath ldquogeneral exhaust ventilationrdquo means an opening in a building designed to exhaust directly from
the building into the air For the purpose of this industry standard general exhaust ventilationexcludes a washroom fan
ldquohighest-ranking individualrdquo means the most senior individual at a metal finishing facility whohas management responsibilities relating to the facility
ldquoHEPA filterrdquo means a high-efficiency particulate air filter ldquoindustry standardrdquo has the same meaning as in subsection 1(1) of O Reg 41905 ldquolocal exhaust ventilation systemrdquo means a system used to capture a contaminant at or near the
point where the contaminant is generated and may be composed of one or more of thefollowing pieces of equipment a hood blast gate ductwork damper and fan
ldquomake-up air unitrdquo means equipment used to supply air into a building or an area of a building ina controlled manner
ldquometal finishing facilityrdquo means a facility that is part of a class identified by NAICS code 332810at which at least one of the following processes takes place 1 Decorative chromium electroplating2 Hard chromium electroplating3 Chromium anodizing4 Chromium reverse etching5 Nickel electroplating6 Electroless nickel plating
ldquometal finishing tankrdquo means a container in which decorative chromium electroplating hardchromium electroplating chromium anodizing chromium reverse etching nickel electroplatingor electroless nickel plating takes place
ldquoMinisterrdquo means the Minister of the Environment and Climate Change or such other member ofthe Executive Council as may be assigned the administration of this Act under the Executive Council Act
ldquoMinistryrdquo means the ministry of the Minister ldquoNAICSrdquo has the same meaning as in subsection 1 (1) of O Reg 41905
ldquonew metal finishing facilityrdquo means a metal finishing facility the construction of which beganafter July 1 2016 and no application was made on or before that day for an environmentalcompliance approval in respect of the facility
ldquonickel electroplatingrdquo means the passage of an electrical current through a solution containingnickel and nickel compounds in order to produce a layer of nickel on the surface of a metal orother substrate
ldquoO Reg 41905rdquo means Ontario Regulation 41905 (Air Pollution ndash Local Air Quality) made under the Act
ldquorecordrdquo includes a written procedure a measurement result a written notification a table areport a document information provided to the highest-ranking individual for review a writtenpractice anything required by this industry standard to be recorded and an update to any ofthe preceding
160Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
ldquoregistered contaminantrdquo means a contaminant that may be discharged into the air from a facility if a person is registered in respect of this industry standard the facility and thecontaminant
ldquoregistered personrdquo means a person that is registered on the Ministryrsquos Technical StandardsRegistry ndash Air Pollution in respect of this industry standard a metal finishing facility and oneor more contaminants listed in Appendix 5-A
ldquoregistrationrdquo means registration on the Ministryrsquos Technical Standards Registry ndash Air Pollution in respect of this industry standard
ldquoreverse etchingrdquo means the passage of an electrical current through a solution containing oneor more chromium compound (hexavalent) in a tank connected to a rectifier in order toproduce an etch on the surface of a metal or other substrate
ldquosurface tensionrdquo means the molecular force measured in dynes per centimetre (dyncm) thatexists at the interface between a solution and a gas
ldquotechnical standardrdquo has the same meaning as in subsection 1 (1) of O Reg 41905
ldquoventilation coordinatorrdquo means an individual appointed in writing by a registered person whohas a level of authority adequate to be responsible for the design installation modificationoperation and maintenance requirements related to optimizing the capture of contaminants bythe ventilation systems at a metal finishing facility
ldquowet scrubberrdquo means a device that uses a scrubbing liquid to remove contaminants from agaseous stream prior to its discharge into the air and
ldquowetting agentrdquo means a compound that reduces surface finishing defects and may also reducethe surface tension of the bath
(2) In this industry standard a reference to the Director means(a) the Director appointed under section 5 of the Act in respect of the section of this industry
standard in which the reference appears(b) if no Director described in clause (a) has been appointed in respect of a section of this
industry standard any Director appointed under section 5 of the Act in respect of section271 or paragraph 3 of subsection 11 (1) of O Reg 41905
(3) If this industry standard requires a measurement of surface tension in a tank themeasurement shall be performed using one of the following monitoring methods
1 A tensiometer used in accordance with an operating manual provided by the manufactureror instructions provided by the supplier
2 A stalagmometer used in accordance with an operating manual provided by themanufacturer or the method entitled ldquoReference Method for Measuring the SurfaceTension of Chromium Electroplating Chromium Anodizing and Reverse EtchingSolutions with a Stalagmometerrdquo published by Environment Canada as amended fromtime to time
3 A method of measurement that in the opinion of the Director would measure surfacetension in the tanks at least as accurately as a method mentioned in paragraph 1 or 2
Application 2 (1) This industry standard applies in accordance with subsections (2) and (3) to a person
who is registered on the Ministryrsquos Technical Standards Registry - Air Pollution in respect of (a) this industry standard(b) a metal finishing facility and(c) one or more of the contaminants listed in Appendix 5-A
161Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(2) If the person mentioned in subsection (1) is registered with respect to a facility set out inColumn 1 of Table 5-2 and one or more of the contaminants listed in an Appendix set out in Column 2 of Table 5-2 the sections set out opposite the Appendix in Column 3 of Table 5-2 apply in respect of the person
(3) Subject to subsection (4) a person mentioned in subsection (1) is required to comply withthe sections of this industry standard that apply to the person in accordance with subsection (2)on or before the date the person registers on the Ministryrsquos Technical Standards Registry ndash AirPollution unless a different date is specified in this industry standard
(4) Sections 6 to 22 do not apply to a person mentioned in subsection (1) in respect of aregistered contaminant before the later of
(a) the date on which the metal finishing facility is first registered in respect of this industrystandard and the registered contaminant and
(b) January 1 2018
TABLE 5-2 Application
Item Column 1 Facility Type
Column 2 Appendix
Column 3 Applicable Sections
1 Metal Finishing Facility
Appendix 5-A Chromium compounds (hexavalent) and Nickel and nickel compounds
1 2 5 6 except for 6 (2) 8 7 8 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
2 Metal Finishing Facility
Appendix 5-B Chromium compounds (hexavalent)
3 6 (2) 8 9
3 Metal Finishing Facility
Appendix 5-C Nickel and nickel compounds
4
PART II - TECHNOLOGY SPECIFICATION
Specified technology ndash chromium compounds (hexavalent) 3 (1) A registered person shall not use or cause or permit the use of a metal finishing tank
for decorative chromium electroplating hard chromium electroplating chromium anodizing orchromium reverse etching unless the tank meets at least one of the following requirements
1 The discharges of chromium compounds (hexavalent) from the tank are captured by alocal exhaust ventilation system and conveyed to an air pollution control device
2 A fume suppressant is used in the tank3 The tank is covered by a tank cover that meets the following criteria
i the cover is capable of enclosing the open surface area of the tank completelyii the cover has a seal that joins the tank cover to the tankiii the cover has a membrane inset with a minimum surface area of 028 m2kA of
currentiv the cover has a membrane inset with pore openings that are less than or equal to
1microm and
162Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
v an evacuation device is attached to the outside of the tank cover The evacuationdevice must contain a HEPA filter with pore openings that are less than or equal to01microm
(2) If the metal finishing tank mentioned in subsection (1) is in a new metal finishing facility oris a metal finishing tank added or replaced as part of a facility expansion the air pollutioncontrol device mentioned in paragraph 1 of subsection (1) shall be one of the following devices
1 A packed bed scrubber with or without a HEPA filter attached2 A composite mesh pad scrubber with or without a HEPA filter attached3 A device that in the opinion of the Director when operated in a specified manner has a
removal efficiency that is equivalent to or better than the removal efficiency of a devicementioned in paragraph 1 or 2
(3) Paragraph 3 of subsection (2) only applies if the registered person has submitted arequest to the Director in respect of the device and the request includes the following information
1 A rationale for the request2 Each metal finishing tank associated with the device3 Documentation that demonstrates the removal efficiency of the device
Specified technologies - Nickel and nickel compounds 4 (1) Subject to subsection (2) a registered person shall not use or cause or permit the use
of a metal finishing tank for nickel electroplating unless the tank meets at least one of thefollowing requirements
1 The discharges of nickel and nickel compounds from the tank are captured by a localexhaust ventilation system and conveyed to an air pollution control device
2 A wetting agent is used in the tank(2) Subsection (1) does not apply to an existing metal finishing facility except in respect of a
tank that is part of a bright or semi-bright nickel electroplating process(3) If the metal finishing tank mentioned in subsection (1) is in a new metal finishing facility or
is a metal finishing tank added or replaced as part of a facility expansion the air pollutioncontrol device mentioned in paragraph 1 of subsection (1) shall be one of the following devices
1 A packed bed scrubber with or without a HEPA filter attached2 A composite mesh pad scrubber with or without a HEPA filter attached3 A device that in the opinion of the Director when operated in a specified manner has a
removal efficiency that is equivalent to or better than the removal efficiency of a devicementioned in paragraph 1 or 2
(4) Paragraph 3 of subsection (3) only applies if the registered person has submitted arequest to the Director in respect of the device and the request includes the following information
1 A rationale for the request2 Each metal finishing tank associated with the device3 Documentation that demonstrates the removal efficiency of the device
Vertical and unimpeded discharges 5 (1) Subject to subsection (2) a registered person shall not on or after January 1 2018
install or cause or permit the installation of a stack at a metal finishing facility unless the stack isvertical and the discharges from the stack are unimpeded
(2) Subsection (1) only applies to a stack that may discharge a registered contaminant
163Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
PART III ndash OPERATION AND MAINTENANCE
Operating Parameter Summary Table 6 (1) A registered person shall ensure that a table entitled ldquoOperating Parameter Summary
Tablerdquo is prepared in accordance with this section (2) The columns of the Operating Parameter Summary Table shall contain the following
information 1 Column 1 If there is a method set out in Table 5 - 6 that is at a metal finishing
facility each piece of equipment at the metal finishing facility from which thedischarge of a registered contaminant is prevented minimized or reduced by the method
2 Column 2 Opposite each piece of equipment required to be set out by paragraph 1 eachlocal exhaust ventilation system and general exhaust ventilation associated with the pieceof equipment
3 Column 3 Opposite each piece of equipment required to be set out by paragraph 1 eachmethod set out in Table 5 - 6 that prevents minimizes or reduces the discharge of aregistered contaminant from the piece of equipment
4 Column 4 Opposite each method required to be set out by paragraph 3 each relevantoperating parameter for the method Relevant operating parameters may include surfacetension and pressure differential
5 Column 5 Opposite each operating parameter required to be set out in by paragraph 4the frequency with which the operating parameter will be measured If an operatingparameter cannot be measured the frequency with which the operating parameter will bemonitored
6 Column 6 Opposite each frequency required to be set out by paragraph 5 the location atwhich the operating parameter will be measured or monitored
7 Column 7 Opposite each location required to be set out by paragraph 6 the range ofvalues in which the method will be considered to be operating normally
8 Column 8 If an operating parameter is set out in Table 5-6 for a method mentioned inItem 1 2 4 5 6 7 8 9 10 11 12 13 14 or 15 of Table 5-6 that is associated with aregistered contaminant that is chromium compounds (hexavalent) opposite eachnormal operating range required to be set out by paragraph 7 the range of values outsideof which notification must be given to the Ministry in accordance with section 9 Afrequency above which notification must be given to the Ministry may also be set out inColumn 8
(3) If a metal finishing tank that is subject to section 3 or 4 is associated with a local exhaustventilation system the information in Columns 1 to 3 for the tank shall be repeated in a new rowof the Operating Parameter Summary Table and information for the row shall be as follows
1 Column 4 Opposite each local exhaust ventilation system required to be set in Column 2each relevant operating parameter for the local exhaust ventilation system including staticpressure in critical ducts
2 Column 5 Opposite each operating parameter required to be set out by paragraph 1 thefrequency with which the operating parameter for the local exhaust ventilation system willbe measured
3 Column 6 Opposite each measurement frequency required to be set out by paragraph 2the location at which the operating parameter for the local exhaust ventilation system willbe measured
164Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
4 Column 7 Opposite each measurement location required to be set out by paragraph 3the range of values in which the local exhaust ventilation system will be considered to beoperating normally
(4) A requirement in subsection (2) or (3) to set out a range of values may be satisfied bysetting out a single value or a different indicator of normal operation such as a power source or pilot light being on or off
(5) Subject to subsection (6) for each method set out in Column 3 of Table 5-6 that is at ametal finishing facility the information set out in Columns 4 to 8 of an Operating ParameterSummary Table shall include the information set out in Columns 4 to 8 of Table 5-6
(6) The information set out in Columns 4 to 7 of an Operating Parameter Summary Table fora baghouse that meets the criteria set out in subsection (7) may be as follows
1 Column 4 Consistent with a recommendation made by a professional each operatingparameter that is considered relevant to determining the proper operation of thebaghouse
2 Column 5 For each operating parameter required by paragraph 1 a measurementfrequency that is consistent with a recommendation made by a professional and is no lessthan daily
3 Column 6 For each operating parameter required by paragraph 1 a location at which theoperating parameter will be measured that is consistent with a recommendation made bya professional
4 Column 7 For each operating parameter required by paragraph 1 the range of valuesrecommended by a professional as indicating that the baghouse is operating normally
(7) The information mentioned in subsection (6) may be set for a baghouse that meets thefollowing criteria
1 The baghouse has a continuously operating bag leak detection system2 The baghouse has audio and visual leak detection alarms that will alert employees to
leaks(8) Where this section or Table 5-6 refers to an operating parameter frequency location or
range that is to be consistent with a recommendation made by a professional the recommendation and the source of the recommendation shall be set out in the Operating Parameter Summary Table
(9) The source of a professional recommendation mentioned in subsection (8) shall be one ofthe following documents
1 An operating and maintenance manual provided by a manufacturer of the thing for whichthe recommendation is being given
2 Written instructions provided by a supplier of the thing for which the recommendation isbeing given
3 A letter from a manufacturer mentioned in paragraph 1 or a supplier mentioned inparagraph 2 setting out the recommendation
4 A letter from a professional engineer setting out the recommendation the rationale for therecommendation and a description of the relevant experience with respect to therecommendation being made The engineer must have relevant experience with respectto the recommendation being made
(10) The Director may order a registered person to(a) include information in Columns 4 to 8 of the Operating Parameter Summary Table if the
Director is of the opinion that the information is necessary to ensure the normal operationof the method or local exhaust ventilation system as applicable or
(b) remove information from Columns 4 to 8 of the Operating Parameter Summary Table ifthe Director is of the opinion that the information is not appropriate to ensure the normaloperation of the method or local exhaust ventilation system as applicable
165Ontario Ministry of the Environment and Climate Change
Column 7
Normal Operating
Range (Method)
Item
Column 8
Notification Range (Method)
Equipment Ventilation Fume Surface Daily Tensiometer in Less than 35 Less than 35 dynescm 1 System Suppressant Tension the Metal dynescm
(dynescm) Finishing Tank
2
Equipment Ventilation System
Fume Suppressant
Surface Tension (dynescm)
Daily Stalagmometer in the Metal Finishing Tank
Less than 45 dynescm
Less than 45 dynescm
Equipment Ventilation Wetting Surface A frequency Metal Finishing A range Not applicable
3 System Agent Tension
(dynescm) consistent with a professional
Tank consistent with a professional
recommendation recommendation
4
Equipment Ventilation System
Venturi Scrubber
Scrubbing liquid flow rate
Daily Inlet to the scrubber
A range consistent with a professional recommendation
The value of the operating parameter is not within the range set out in Column 7 for three or more days in a calendar week
5
Equipment Ventilation System
Venturi Scrubber
Pressure differential
Daily 1Inlet to thescrubber
2Outlet to thescrubber
A range consistent with a professional recommendation
The value of the operating parameter is not within the range set out in Column 7 for three or more days in a calendar week
Normal Operating
Range (Method)
Column 7 Column 6
Measurement
(Method) Location
Column 5
Measurement Frequency (Method)
Column 4
Operating Parameter (Method)
Column 3
Associated Method
Column 2
Associated Ventilation Systems
Column 1
Equipment
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(11) No later than five days after a change is made at the metal finishing facility that wouldaffect the information in the Operating Parameter Summary Table the Table shall be updated to reflect the change
(12) A reference in Column 5 of Table 5-6 to a scrubber that is new is a reference to ascrubber that discharges a registered contaminant that is installed at the facility after the later of
(a) the date on which the metal finishing facility is first registered in respect of this industrystandard and the registered contaminant and
(b) July 1 2018
TABLE 5-6 Structure for Operating Parameter Summary Table
166Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Equipment
Column 2
Associated Ventilation Systems
Column 3
Associated Method
Column 4
Operating Parameter (Method)
Column 5
Measurement Frequency (Method)
Column 6
Measurement Location (Method)
Column 7
Normal Operating
Range (Method)
Column 8
Notification Range (Method)
6
Equipment Ventilation System
Venturi Scrubber
pH of scrubbing liquid (if applicable)
Daily A location consistent with a professional recommendation
A range consistent with a professional recommendation
The value of the operating parameter is not within the range set out in Column 7 for three or more days in a calendar week
7
Equipment Ventilation System
Packed Bed Scrubber
Scrubbing liquid flow rate
Daily (if not a new scrubber)
Inlet to the scrubber
A range consistent with a professional recommendation
The value of the operating parameter is not within the range set out in Column 7 for three or more days in a calendar week
8
Equipment Ventilation System
Packed Bed Scrubber
Scrubbing liquid flow rate
Continuously (if a new scrubber)
Inlet to the scrubber
A range consistent with a professional recommendation
The value of the operating parameter is not within the range set out in Column 7 on any three days in a calendar week
9
Equipment Ventilation System
Packed Bed Scrubber
Velocity Pressure
Daily A location consistent with a professional recommendation
A range consistent with a professional recommendation
The value of the operating parameter is not within the range set out in Column 7 for three or more days in a calendar week
10
Equipment Ventilation System
Packed Bed Scrubber
Pressure Differential
Daily (if not a new scrubber)
1Inlet to thescrubber
2Outlet to thescrubber
A range consistent with a professional recommendation
The value of the operating parameter is not within the range set out in Column 7 for three days or more in a calendar week
11
Equipment Ventilation System
Packed Bed Scrubber
Pressure Differential
Continuously (if a new scrubber)
1Inlet to thescrubber
2Outlet to thescrubber
A range consistent with a professional recommendation
The value of the operating parameter is not within the range set out in Column 7 on any three days in a calendar week
12
Equipment Ventilation System
Packed Bed Scrubber
pH of scrubbing liquid (if applicable)
Daily (if not a new scrubber)
A location consistent with a professional recommendation
A range consistent with a professional recommendation
The value of the operating parameter is not within the range set out in Column 7 for three or more days in a calendar week
167Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Equipment
Column 2
Associated Ventilation Systems
Column 3
Associated Method
Column 4
Operating Parameter (Method)
Column 5
Measurement Frequency (Method)
Column 6
Measurement Location (Method)
Column 7
Normal Operating
Range (Method)
Column 8
Notification Range (Method)
13
Equipment Ventilation System
Packed Bed Scrubber
pH of scrubbing liquid (if applicable)
Continuously (if a new scrubber)
A location consistent with a professional recommendation
A range consistent with a professional recommendation
The value of the operating parameter is not within the range set out in Column 7 on any three days in a calendar week
14
Equipment Ventilation System
Composite Mesh Pad Scrubber
Pressure Differential
Daily (if not a new scrubber)
1Inlet to thescrubber
2Outlet to thescrubber
A range consistent with a professional recommendation
The value of the operating parameter is not within the range set out in Column 7 for three or more days in a calendar week
15
Equipment Ventilation System
Composite Mesh Pad Scrubber
Pressure Differential
Continuous (if a new scrubber)
1Inlet to thescrubber
2Outlet to thescrubber
A range consistent with a professional recommendation
The value of the operating parameter is not within the range set out in Column 7 on any three days in a calendar week
16
Equipment Ventilation System
Baghouse Pressure Differential
Daily 1Inlet to thebaghouse
2Outlet to thebaghouse
A range consistent with a professional recommendation
Not applicable
17
Equipment Ventilation System
A method required by section 24 and any other section in this industry standard that requires a method
One or more operating parameters consistent with a profession al recommen dation
A frequency consistent with a professional recommendation
A location consistent with a professional recommendation
A range consistent with a professional recommendation
Not applicable
Item Equipment Associated Ventilation Systems
Associated Method
Operating Parameter
(LEV)
Measurement Frequency
(LEV)
Measurement Location (LEV)
Normal Operating
Range (LEV)
Notification Range (LEV)
18
Equipment Local Exhaust Ventilation System (LEV)
Method Static Pressure
A frequency consistent with a professional recommendation
Critical ducts of the LEV
A range consistent with a professional recommendation
Not applicable
168Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Measurement of operating parameters 7 (1) A registered person shall ensure that measurements are taken and recorded in
accordance with this section (2) Each operating parameter set out in Column 4 of the Operating Parameter Summary
Table required by section 6 shall be measured at least as often as the frequency set out inColumn 5 of the Table at the location set out in Column 6 of the Table
(3) If an Operating Parameter Summary Table sets out an operating parameter for abaghouse that is required to be measured on a daily basis the measurement taken and recorded for the purposes of this section shall be taken when the baghouse is not in a bagcleaning cycle
(4) Immediately before using a metal finishing tank that has not been used in the preceding24-hour period the surface tension in the tank shall be measured if the tank is
(a) a metal finishing tank subject to section 3 that uses a fume suppressant or(b) a metal finishing tank subject to section 4 that uses
(i) a wetting agent and a carbon pack or(ii) a batch treatment
(5) Subject to subsection (6) the following information shall be recorded1 Each measurement required to be taken under subsections (1)2 If a measurement mentioned in paragraph 1 is surface tension the methodology used to
take the measurement having regard to subsection 1 (3)3 The date on which each measurement mentioned in paragraph 1 was taken(6) Subsection (5) does not apply with respect to a baghouse that meets the criteria set out in
subsection 6 (7) or to equipment set out in an Operating Parameter Summary Table for thepurpose of Item 17 of Table 5-6
Deviations from operating parameters 8 (1) For each method and local exhaust ventilation system set out in the Operating
Parameter Summary Table required by section 6 a registered person shall ensure the followingsteps are taken
1 Determine if the measured value for each operating parameter set out opposite themethod or system deviates from the normal operating range of values set out in Column 7opposite operating parameter
2 Subject to subsection (3) if it is determined under paragraph 1 that a value deviated fromthe normal operating range make one or more operational adjustments as soon aspracticable so that the value of the operating parameter is within the normal operatingrange
(2) If an operational adjustment is required to be made under paragraph 2 of subsection (1)the registered person shall ensure that the following information is recorded
1 The operating parameter for which the value was measured2 The method or local exhaust ventilation system to which the operating parameter
mentioned in paragraph 1 relates3 The normal operating range for the operating parameter mentioned in paragraph 14 The measured values of the operating parameter mentioned in paragraph 1 taken during
the duration of the deviation5 If the operating parameter is surface tension the method that was used in accordance
with subsection 1 (3)6 The date time and duration of the deviation7 An explanation of the suspected cause of the deviation
169Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
8 A description of each operational adjustment required to be made under paragraph 2 ofsubsection (1) and the date each operational adjustment was completed
9 The position title of each personnel who assigned a person to make an operationaladjustment mentioned in paragraph 8
(3) Paragraph 2 of subsection (1) does not apply with respect to a value for a baghouseoperating parameter that was recorded during a bag cleaning cycle
Notification of deviations from operating parameters 9 (1) Subject to subsection (2) if in accordance with section 6 a notification range is
required to be set out in Column 8 of an Operating Parameter Summary Table a registeredperson shall ensure that as soon as practicable a provincial officer is notified in writing if thevalue of an operating parameter deviates from the notification range with the frequency set outin the Table if any
(2) If a person is required to notify under subsection (1) more than one time in a 24-hourperiod the person may instead of complying with subsection (1) notify a provincial officer inwriting as soon as practicable after the end of the 24-hour period of the number of deviationsthat occurred during the period
Phase-In for new air pollution control devices 10 Sections 6 to 9 do not apply in respect of an air pollution control device or local ventilation
system at a metal finishing facility for a period of six months after the installation of the deviceor system if the device or system is installed after the date on which the metal finishing facility is first registered with respect to this industry standard
Inspection and Maintenance Summary Table 11 (1) A registered person shall ensure that a table entitled ldquoInspection and Maintenance
Summary Tablerdquo is prepared in accordance with this section(2) The columns of the Inspection and Maintenance Summary Table shall contain the
following information 1 The first column shall contain
i each air pollution control device at the metal finishing facility that is associated with aregistered contaminant
ii each local exhaust ventilation systemA required by paragraph 1 of subsection 3(1)B required by paragraph 1 of subsection 4(1) orC that is the subject of a plan required by subsection 20 (7) and
iii each monitoring device at the metal finishing facility used to take a measurement thatis required by this industry standard including stalagmometers tensiometerspressure gauges flow meters pH meters and building differential pressure monitors
2 Opposite each thing required to be set out by paragraph 1 the frequency with which eachthing is to be inspected to ensure its proper operation
3 Opposite each inspection frequency required to be set out by paragraph 2 themaintenance objectives to be verified by the inspection
(3) Subject to subsection (4) for each thing identified in Column 1 of Table 5-11 theinformation set out in the Inspection and Maintenance Summary Table opposite the item shall include the information set out in Columns 2 and 3 of Table 5-11
(4) An Inspection and Maintenance Summary Table may set out a frequency other than afrequency set out in Column 2 of Table 5-11 if the substituted frequency is based on a recommendation made by a professional
(5) Where this section or Table 5-11 refers to a thing that is to be consistent with arecommendation made by a professional the recommendation and the source of the recommendation shall be set out in the Inspection and Maintenance Summary Table
170Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(6) The source of a recommendation mentioned in subsection (5) shall be one of thefollowing documents
1 An inspection frequency set out in an operating and maintenance manual provided by amanufacturer of the thing for which the recommendation is being given
2 An inspection frequency set out in written instructions provided by a supplier of the thingfor which the recommendation is being given
3 A letter from a manufacturer mentioned in paragraph 1 or a supplier mentioned inparagraph 2 that has relevant experience with metal finishing processes and equipmentsetting out the recommended inspection frequency
4 A letter from a professional engineer setting out the recommended inspection frequencythe rationale for the recommendation and a description of the relevant experience withrespect to the recommendation being made The engineer must have relevant experiencewith respect to the recommendation being made
(7) The Director may order a registered person to(a) include information in Columns 1 to 3 of the Inspection and Maintenance Summary
Table if the Director is of the opinion that the information is necessary to ensure thenormal operation of the air pollution control device ventilation system or monitoringdevice as applicable or
(b) remove information from Columns 1 to 3 of the Inspection and Maintenance SummaryTable if the Director is of the opinion that the information is not appropriate to ensurethe normal operation of the air pollution control device ventilation system or monitoringdevice as applicable
(8) No later than five days after a change is made at the metal finishing facility that wouldaffect the information in the Inspection and Maintenance Table the Table shall be updated toreflect the change
TABLE 5-11 Structure for Inspection and Maintenance Summary Table
Item Column 1
Air Pollution Control DeviceVentilation SystemMonitoring Device
Column 2
Inspection Frequency
Column 3
Maintenance Objective
1 Wet Scrubber Weekly i Each chemical metering pump is operating properly ii Each probe is operating properly
iii No flow strainer is clogged
2 Wet Scrubber Monthly i No fan housing drain is clogged ii No solids build-up or erosion on each fan impeller and blade
iii No leaks anywhere in the wet scrubber system iv Each damper system is operating properly
3 Wet Scrubber Quarterly i No excessive wear corrosion or build-up of residue on the wet scrubber media or the main body of the wet scrubber
ii Piping is not eroding or clogged
4 Wet Scrubber At least one time in every six-month period
i No excessive current draw on pumps and fans (measure the current draw to verify)
171Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Air Pollution Control DeviceVentilation SystemMonitoring Device
Column 2
Inspection Frequency
Column 3
Maintenance Objective
5 Wet Scrubber A frequency consistent with a professional recommendation
i No leaks cracks or loose fittings on the fan and fan bearings ii No pump or fan motor is making unusual vibration heat or noise
iii No spray nozzle or bar is clogged iv The distribution pattern for spray nozzles and bars do not indicate
excessive wear v The fan bearings belts and seals are in good condition
vi The pumps and fans have been greased with the recommended frequency
6 Packed Bed Scrubber
A frequency consistent with a professional recommendation
i Packing media and trays are maintained as per professional recommendations
ii No breakthrough in the back portion of packed bed scrubber iii No leaks in the ductwork from tank to the scrubber
7 Composite Mesh Pad Scrubber
A frequency consistent with a professional recommendation
i Each mesh pad has been washed with the recommended frequency ii No build-up of residue on the mesh pads iii No mesh pad is corroding iv No breakthrough in the back portion of the mesh pads v No leaks in the ductwork from tank to the scrubber
8 Baghouse Weekly i No visual evidence of abnormal discharges
9 Baghouse Monthly i Dust hopper is not likely to overflowii No visual evidence of holes or wear in ducts hoods expansion
joints or flex connections of fume capture equipment iii No visual evidence of flow constrictions caused by dents in ducts or
misaligned expansion joints and flex connections of ventilation equipment
iv No visual evidence of fan housing erosionv Dampers are at the proper settings
10 Baghouse At least one time in every six-month period
i No visual evidence of damaged bags cleaning mechanism components dampers and spare parts are available if needed
ii No loose or worn belts in the fan or blower iii Impellers in the fanblower are properly balancediv No wear erosion or dust accumulation on an impeller in the fan or
blower v No erosion of air lock or conveyor system housings in the dust
removal conveyor system vi No unusual vibration or squealing with respect to the fanblower or
dust removal system (including airlocks and screw conveyor)
vii All bearings in the fan and blower and dust removal system are adequately lubricated
11 Baghouse Annually i No sign of corrosion on any weld joint or seal ii All fasteners are tightly in place
iii All welds joints and seals are clean and painted to avoid rusting
12 Local Exhaust Monthly i Slide gates are correctly positioned
172Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1
Air Pollution Control DeviceVentilation SystemMonitoring Device
Column 2
Inspection Frequency
Column 3
Maintenance Objective
Ventilation System ii Dampers that are not secured in place on critical ducts fora metal finishing tank that is subject to section 3 or 4 arecorrectly positioned
13 Local Exhaust Ventilation System
Annually i Dampers that are secured in place on critical ducts for a metalfinishing tank that is subject to section 3 or 4 are correctlypositioned
14 Tank Cover A frequency consistent with a professional recommendation
Maintenance objectives consistent with a professional recommendation
15 Monitoring Device A frequency consistent with a professional recommendation
Monitoring device is measuring accurately
Inspection and maintenance activities 12 (1) A registered person shall ensure that each thing set out in Column 1 of the Inspection
and Maintenance Summary Table required by section 11 is inspected with the frequency set outin Column 2 of the Table to verify whether the maintenance objectives set out in Column 3 aremet
(2) A registered person shall ensure that the following information is recorded1 The date of each inspection performed for the purpose of subsection (1)2 Based on the date in paragraph 1 and the date of the previous inspection performed for
the purpose of subsection (1) an indication of whether the inspection was performed withthe required frequency
3 An indication of which maintenance objectives were not met4 The title of each personnel who assigned a person to perform the inspection mentioned in
paragraph 1
Deviations - inspection and maintenance 13 (1) No later than the last day of each month a registered person shall ensure that the
records required by section 12 are reviewed to determine if (a) complying with each inspection required by section 12 was performed with the frequency
set out opposite the activity during the month and(b) an inspection revealed that any maintenance objectives were not met
(2) If it is determined under clause (1)(a) that an inspection was not performed with therequired frequency the registered person shall ensure that the following information isrecorded
1 A description of the inspection that was to be performed2 The date on which the inspection was to be performed
173Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
3 The reason the inspection was not performed with the required frequency4 A description of actions to be taken to ensure the inspection will be performed with the
required frequency5 The title of each personnel who assign a person to take the actions mentioned in
paragraph 4(3) If it is determined under clause (1)(b) that a maintenance objective was not met the
registered person shall ensure that one or more actions are taken as soon as practicable tomeet the maintenance objective
(4) If an action is required to be taken under subsection (3) the registered person shallensure that the following information is recorded
1 A description of the maintenance objective that was not met2 The reason the maintenance objective was not met3 A description of each action to be taken to ensure the maintenance objective is met4 The date on which each action was taken5 The title of personnel who assigned a person to take an action mentioned in paragraph 3
Recurring malfunctions 14 (1) Subject to subsection (3) if an air pollution control device or a local exhaust
ventilation system at a metal finishing facility malfunctions in the same way more than one timein any six-month period the registered person shall ensure that the ventilation coordinatornotifies the highest-ranking individual at the metal finishing facility in writing of the malfunctionno later than five days after the second malfunction
(2) If notification is required to be made under subsection (1) the registered person shallensure that the ventilation coordinator as soon as practicable after the date of the secondmalfunction prepares and implements a plan to address and prevent a recurrence of themalfunction
(3) Subsection (1) applies only to(a) an air pollution control device that may discharge a registered contaminant and(b) a local exhaust ventilation system that may capture or convey a registered contaminant
PART IV ndash INDUSTRIAL VENTILATION
Building areas to be negatively pressured 15 (1) If paragraph 1 of subsection 16 (2) applies in respect of an area of a metal finishing
facility the registered person shall maintain the area at a negative pressure(2) If paragraph 2 of subsection 16 (2) applies in respect of an area of a metal finishing
facility the registered person shall ensure that no more than one 30-minute block average ofbuilding differential pressure in the area is positive in a calendar day
(3) A registered person shall ensure that as soon as practicable a provincial officer isnotified in writing if an update of a table mentioned in paragraph 1 of subsection 16 (2)demonstrates that the sum of Column 2 of the table is greater than the sum of Column 4
(4) No later than 30 days after notification is required to be given under subsection (3) theregistered person shall ensure that the following information is submitted in writing to theDistrict Manager
1 The date the table was updated2 A copy of the updated table3 An identification of each metal finishing tank that is subject to sections 3 or 4 in the area to
which the table relates(5) A registered person shall ensure that as soon as practicable a provincial officer is
notified in writing of a contravention of subsection (2)
174Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(6) If a person contravenes subsection (2) more than once in a calendar day the personmay instead of complying with subsection (5) notify a provincial officer in writing as soon aspracticable after the end of the calendar day of the number of contraventions that occurredduring the day
(7) No later than 30 days after notification is required to be given under subsection (5) or (6)the registered person shall ensure that the following information is submitted in writing to theDistrict Manager
1 The date of the contravention2 The number of contraventions that occurred on the date mentioned in paragraph 1 and
the time each contravention occurred3 For each contravention mentioned in paragraph 2 the measured value of the building
differential pressure4 An identification of each monitor that indicated the positive building differential pressure5 An identification of each piece of equipment located near each monitor mentioned in
paragraph 4
Ventilation program 16 (1) A registered person shall appoint a ventilation coordinator and ensure that the
ventilation coordinator develops and implements a ventilation program in accordance with thissection
(2) For the purpose of the ventilation program one of the following actions shall be taken foreach area of the metal finishing facility in which a metal finishing tank that is subject to section 3or 4 is enclosed
1 A table is prepared in accordance with section 172 Measurements are taken in accordance with section 18(3) If a 30-minute block average measurement taken for the purpose of paragraph 2 of
subsection (2) is positive the registered person shall ensure that one or more operationaladjustments are made as soon as practicable to return the area to negative pressure
(4) The following information shall be recorded as part of the ventilation program1 A description of each ventilation system at the metal finishing facility2 For each ventilation system described for the purposes of paragraph 1 the specifications
of each fan in the system including the volumetric flow rate of the fan3 A process flow diagram of each ventilation system described for the purposes of
paragraph 1 drawn to scale that includes the following informationi Each piece of equipment from which emissions may be captured by the ventilation
systemii Each air pollution control device associated with a piece of equipment mentioned in
subparagraph iiii Key information about the ventilation system including volumetric flow rates
4 A drawing of each ventilation system described for the purposes of paragraph 1 thatreflects as-built condition The drawing shall be based on the specifications of the systemthat was installed not the design specifications
5 For each area of the metal finishing facility in which a metal finishing tank that is subject tosection 3 or 4 is enclosed either
i a table prepared in accordance with section 17 orii each block average recorded in accordance with section 18
6 For each block average mentioned in subparagraph 5 ii that is a positive valuei the date and time that the 30-minute block average of building differential pressure
was positive
175Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
ii an explanation of the suspected cause of the positive pressureiii a description of each operational adjustment required to be made under subsection
(3) and the date each operational adjustment was completed andiv the position title of personnel who assigned a person to make an operational
adjustment mentioned in subparagraph iii(5) A ventilation system mentioned in subsection (4) includes general exhaust ventilation a
local exhaust ventilation system and a make-up air unit but does not include a ventilationsystem contained wholly within an area that is isolated from metal finishing processes
Volumetric flow rates in and out of building areas 17 (1) The table mentioned in paragraph 1 of subsection 16 (2) shall set out the following
information in the manner illustrated by Table 5-17 1 Each make-up air unit in the area shall be listed in Column 1 of the Table2 Opposite each make-up air unit mentioned in paragraph 1 the volumetric flow rate of the
unit shall be set out in Column 2 of the Table3 Each local exhaust ventilation system and each general exhaust ventilation in the area
shall be listed in Column 3 of the Table4 Opposite each thing mentioned in paragraph 3 the flow rate of the system shall be set out
in Column 4 of the Table5 The sum of the flow rates listed in Column 2 of the Table shall be set out in the last row of
Column 26 The sum of the flow rates listed in Column 4 of the Table shall be set out in the last row of
Column 47 The Table shall contain an indication of whether the sum mentioned in paragraph 5 is
greater than the sum mentioned in paragraph 6
TABLE 5-17 Volumetric flow rates in and out of building areas
Item Column 1 Make-up Air Units
Column 2 Volumetric Flow Rate
Column 3 Local Exhaust Ventilation Systems and General ExhaustVentilation
Column 4 Volumetric Flow Rate
1 2 3
Total Flow Rate Entering Enclosed Area Total Flow Rate Exiting Enclosed Area
Building differential pressure 18 (1) The measurements required to be taken by paragraph 2 of subsection 16 (2) shall be
taken by continuously measuring the building differential pressure and recording the building differential pressure in 30-minute block averages
(2) Each measurement required by subsection (1) shall be taken by at least two monitorsthat in the opinion of the Director accurately measure the building differential pressure
(3) For greater clarity at least one monitor required by subsection (2) shall be located insidethe building and at least one monitor shall be located outside of the building
(4) In determining whether the monitors mentioned in subsection (2) accurately measurebuilding differential pressure the Director shall consider the following information
176Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
1 The number of monitors used to take the measurements2 The location of each monitor3 The frequency of measurement4 The wind rose or predominant wind direction5 The internal and external configuration of the building6 The roof heights of the building(5) The location of each monitor required by subsection (2) shall be depicted in a diagram
drawn to scale of the metal finishing facility(6) If a change is proposed that would alter the information contained in the diagram required
by subsection (5) the diagram shall be updated with the proposed change and submitted to theDirector no later than 60 days before the proposed change occurs
Change management - proposed changes to ventilation 19 (1) Subject to subsection (5) prior to implementing a change to a ventilation system at a
metal finishing facility a registered person shall ensure that the following information is recorded
1 A description of the proposed change to the ventilation system2 An evaluation of the possible impacts of the proposed change to the ventilation system on
the ability of the ventilation system to capture contaminants under anticipated operatingscenarios
3 An evaluation of the impact of the proposed change to the ventilation system on thebalance of volumetric flow rates entering and exiting the enclosed area in which theventilation system is located The evaluation may be based on information such as ananalysis of volumetric flow rates or an analysis of building differential pressures
(2) If an evaluation performed under paragraph 2 or 3 of subsection (1) indicates that thecapture of the ventilation system would be reduced a registered person shall not implement orcause or permit the implementation of the proposed change to the ventilation system without awritten record indicating that the highest-ranking individual at the metal finishing facility hasreviewed the proposal and has confirmed that the proposed change meets the requirements setout in subsection 25 (2)
(3) No later than three months after a change mentioned in subsection (1) is implementedthe registered person shall ensure that the information required by subsection 16 (4) is updatedand a record is made of the date on which the changed was implemented
(4) A ventilation system mentioned in subsection (1) includes general exhaust ventilation alocal exhaust ventilation system and a make-up air unit but does not include a ventilationsystem contained wholly within an area that is isolated from metal finishing processes
(5) Subsection (1) does not apply if the following criteria are met1 The ventilation system is associated only with natural gas or propane combustion2 The proposed change to the ventilation system will result in a change to the volumetric
flow rate entering or exiting the enclosed area of the metal finishing facility in which theventilation system is located that is less than the absolute value determined according tothe following equation
|005(A-B)| Where A is the sum determined under paragraph 5 of section 17 and B is the sum determined under paragraph 6 of section 17
Notice - ventilation assessment report 20 (1) The Director may give a registered person a written notice requiring that a Ventilation
Assessment Report is prepared in accordance with the notice if
177Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(a) the ministry is aware of two or more complaints related to a matter addressed in thisindustry standard having been made in respect of the metal finishing facility in theprevious 12-month period
(b) an area of the metal finishing facility in which a metal finishing tank that is subject tosection 3 or 4 is enclosed is not likely operating at negative pressure or
(c) a static pressure measurement in respect of a local exhaust ventilation system is outsideof the range set out in Column 7 of the Operating Parameter Summary Table required bysection 6
(2) A notice given under subsection (1) shall specify each registered contaminant area andventilation system at the metal finishing facility that is subject to the notice
(3) The report required by subsection (1) shall contain the following information with respectto each registered contaminant ventilation system and area specified in the notice
1 The measured duct velocity of the ventilation system2 The measured static pressure of the ventilation system including where feasible the
static pressure of each branch of each local exhaust ventilation system that may captureand convey registered contaminants
3 The volumetric flow rate of the ventilation system The report shall also include themethods used to determine the volumetric flow rate including any calculations
(4) Based on the information required by subsection (3) the report required by subsection (1)shall contain the following information
1 A comparison of total make-up air flow rates to the total combined flow rates of generalexhaust ventilation and the local exhaust ventilation systems
2 A comparison where feasible of the measured static pressure within areas of the buildingthat contain metal finishing processes to the measured ambient static pressure outside ofthe building
(5) If a ventilation system in an area of the metal finishing facility specified in the notice maycapture discharges of a registered contaminant in a non-negligible amount from a metal finishing tank that is subject to section 3 or 4 the report required by subsection (1) shall inaddition to the information required by subsections (3) and (4) include the following information
1 The face velocity of each hood in the ventilation system2 The results of a visual evaluation of fugitive emissions from the metal finishing tank3 The exit velocity for each exhaust stack in the ventilation system4 A depiction that shows the orientation and the configuration of each exhaust stack in the
ventilation system(6) Based on the information mentioned in subsections (3) to (5) the report required by
subsection (1) shall contain an indication of (a) whether the ventilation systems in each area specified in the notice adequately capture
fugitive emissions of one or more registered contaminants and(b) whether any part of a ventilation system in an area specified in the notice is inadequate to
capture fugitive emissions of one or more registered contaminants(7) If in accordance with subsection (6) the report indicates that fugitive emissions of the
registered contaminants are not being adequately captured the registered person shall ensurethat
(a) a written plan is prepared and implemented that sets out actions to be taken to ensurethat fugitive emissions of registered contaminants are adequately captured by theventilation systems and the dates by which each action shall be taken and
(b) a written record is made of the date that each action mentioned in clause (a) isimplemented
(8) A ventilation system mentioned in this section includes general exhaust ventilation a localexhaust ventilation system and a make-up air unit but does not include a ventilation systemcontained wholly within an area that is isolated from the metal finishing processes
(9) The registered person shall ensure that a copy of the report required by subsection (1) issubmitted to the Director and the Manager of the Standards Development Branch of theMinistry no later than the date set out in the notice
178Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(10) Before the Director gives a person a notice under subsection (1) the Director shall givethe person a draft of the notice and an opportunity to make written submissions to the Directorduring the period that ends 30 days after the draft is given
Commissioning of new ventilation equipment 21 (1) On and after July 1 2016 a registered person shall ensure that the ventilation
coordinator complies with the requirements set out in this section(2) Subject to subsection (3) no later than three months after a piece of ventilation
equipment is installed at a metal finishing facility the following actions shall be taken 1 Perform ventilation balancing on each local exhaust ventilation system associated with the
piece of ventilation equipment2 Determine whether the ventilation balancing required by paragraph 1 demonstrates that
each local exhaust ventilation system is adequate to capture and convey each registeredcontaminant associated with the local ventilation system
3 Perform a visual evaluation to determine whether the local exhaust ventilation system isadequately capturing and conveying each registered contaminant associated with thesystem
4 Update the record required by subsection 16 (4) to include the following informationi The results of the ventilation balancing required by paragraph 1 including the
determination required by paragraph 2ii The results of a visual evaluation required by paragraph 3iii A summary of the commissioning activities performed with respect to each local
exhaust ventilation system associated with the piece of ventilation equipment(3) Subsection (2) only applies if the installed ventilation equipment is part of a local exhaust
ventilation system that is associated with a metal finishing tank that is subject to section 3 or 4
Multi-tenant buildings 22 (1) For the purposes of this section a ldquonon-metal finishing tenantrdquo means a tenant that(a) is an occupant in a building that contains a metal finishing facility and(b) does not
(i) provide raw materials products or services to the metal finishing facility or(ii) use raw materials products or services from the metal finishing facility
(2) If a metal finishing facility is located in a building that may have one or more non-metalfinishing tenants the registered person shall on and after July 1 2021
(a) at least one time in every six-month period ensure that new make-up air unit filters foreach make-up air unit at the building is provided to the person responsible for the buildingor
(b) ensure that(i) each metal finishing tank that is subject to section 3 complies with paragraphs 1 and 2
of subsection 3(1) and(ii) each metal finishing tank that is subject to section 4 complies with paragraphs 1 and 2
of subsection 4(1)(3) Clause (2)(a) does not apply with respect to a make-up air filter that is designed to be
cleaned if at least one time in the preceding six-month period the registered person offers inwriting to clean the filter and if the offer is accepted ensures that the filter is cleaned
(4) The registered person mentioned in subsection (2) shall ensure that the followinginformation is recorded
1 For each filter required to be provided under this section the identification of the make-upair unit for which the filter was provided
179Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
2 For each filter required to be cleaned under this section the identification of the make-upair unit for which the filter was cleaned
3 The date that each filter mentioned in paragraphs 1 and 2 was provided or cleaned ifapplicable
PART V ndash REQUIREMENT TO CONTINUE THE USE OF VENTILATION SYSTEMS AND METHODS TO MANAGE EMISSIONS
Identifying managed sources 23 (1) A registered person shall ensure that a table is prepared in accordance with this
section and updated in accordance with section 25(2) The table required by subsection (1) shall contain the following information1 Column 1 Each piece of equipment at the metal finishing facility from which the discharge
of a registered contaminant is prevented minimized or reduced by a method mentioned insubsection (3)
2 Column 2 Opposite each piece of equipment required to be set out by paragraph 1 eachlocal exhaust ventilation system and general exhaust ventilation associated with the pieceof equipment
3 Column 3 Opposite each piece of equipment required to be set out by paragraph 1 eachmethod that prevents minimizes or reduces the discharge of a registered contaminantfrom the piece of equipment
(3) A method mentioned in paragraph 3 of subsection (2) includes a method such as(a) the use of an air pollution control device(b) the selection and use of equipment that more effectively prevents minimizes or reduces
the discharge of a registered contaminant than the selection or use of other equipment(c) the operation of a process or a piece of equipment in a manner that prevents minimizes
or reduces the discharge of a registered contaminant into the air from the process or pieceof equipment
(d) the design installation and operation of a stack in a manner that increases the dispersionof contaminants and
(e) the use of an additive to prevent minimize or reduce the discharge of a registeredcontaminant to the air
(4) If a method mentioned in paragraph 3 of subsection (2) is the selection of equipment inaccordance with clause (3) (b) the equipment shall be listed as the method in Column 3 of thetable and as the equipment in Column 1 of the table
(5) If a new metal finishing facility is not constructed at the time of registration theequipment ventilation systems and methods required to be listed in the table required bysubsection (1) shall until the construction is complete be the proposed equipment ventilationsystems and methods
Requirement to continue the management of sources 24 (1) A registered person shall not operate or cause or permit the operation of a piece of
equipment set out in the table required by section 23 unless (a) the discharge of registered contaminants from the piece of equipment is prevented
minimized or reduced by a method that is at least as effective at preventing minimizing orreducing the discharge into the air as the associated method required to be listed oppositethe piece of equipment in Column 3 of the table and
(b) the discharge of registered contaminants from the piece of equipment is captured by aventilation system that is at least as effective at capturing the discharge as the associated
180Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
ventilation system required to be listed opposite the piece of equipment in Column 2 of thetable
Changes to managed sources 25 (1) No later than 30 days after any of the following changes occur at a metal finishing
facility the table required by section 23 shall having regard to subsection (2) be updated inaccordance with the following rules
1 If a method to prevent minimize or reduce the discharge of a registered contaminant isadded or replaced at the metal finishing facility the table shall be updated to reflect thechange
2 If a ventilation system that captures a registered contaminant is added or replaced at themetal finishing facility the table shall be updated to reflect the change
3 If a piece of equipment that may discharge or from which may be discharged a registeredcontaminant is added or replaced at the metal finishing facility the table shall be updatedto reflect the change
4 If a piece of equipment set out in the table is removed from the metal finishing facility thepiece of equipment shall be removed from the table
5 If all equipment associated with a method set out in the table has been removed from thetable the method shall be removed from the table
6 If all equipment associated with a ventilation system set out in the table have beenremoved from the table the ventilation system shall be removed from the table
7 If a notice given under subsection (4) indicates that a method is no longer necessary themethod shall be removed from the table
8 If a notice given under subsection (4) indicates that a ventilation system is no longernecessary the ventilation system shall be removed from the table
9 If the table is updated in accordance with paragraphs 7 and 8 such that no method orventilation system is set out opposite a piece of equipment in the table the piece ofequipment shall be removed from the table
(2) Subject to subsections (3) and (4) a change mentioned in subsection (1) shall not bemade unless the following criteria are met
1 A change that adds replaces or otherwise alters a method shall add replace or alter themethod in a manner that is at least as effective at preventing reducing or minimizing thedischarge of registered contaminants as the method that was listed in the tableimmediately prior to the change
2 A change that adds replaces or otherwise alters a ventilation system shall add replace oralter the ventilation system in a manner that is at least as effective at capturing registeredcontaminants as the ventilation system that was listed in the table immediately prior to thechange
3 A change that adds a piece of equipment that is similar to a piece of equipment requiredto be set out in the table shall only be made if
i Column 2 of the table contains a ventilation system that is at least as effective atcapturing contaminants as the most effective ventilation system associated with asimilar piece of equipment and
ii Column 3 of the table contains a method that is at least as effective at preventingminimizing or reducing the discharge of registered contaminants as the most effectivemethod associated with a similar piece of equipment
(3) Subsection (2) does not apply if the change is required by a section of this industrystandard other than this section
(4) The Director may upon request give a registered person written notice indicating that achange that does not meet the requirements mentioned in subsection (2) may be made in
181Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
accordance with the notice if the Director is of the opinion that at least one of the followingstatements is true
1 The method or system that is the subject of the request is comparable to the effectivenessof the method or system that would be required by subsection (2)
2 Any adverse effect would likely not be better prevented eliminated or ameliorated if amethod or system required by subsection (2) were used
3 No adverse effect is likely to occur4 The registered contaminants affected by the change are discharged in an amount that is
negligible(5) A request that is made in respect of subsection (4) shall be made by a registered person
and shall include the following information 1 A rationale for the request2 Each piece of equipment associated with the method or system that is the subject of the
request3 Confirmation the piece of equipment mentioned in paragraph 2 does not include a metal
finishing tank that is subject to section 3 or 4(6) Before the Director gives a person a notice under subsection (4) the Director shall give
the person a draft of the notice and an opportunity to make written submissions to the Directorduring the period that ends 30 days after the draft is given
Specified management of sources 26 (1) The Director may order a registered person to use a method or ventilation system if(a) a change was made to a method or ventilation system that in the opinion of the Director
does not meet the criteria set out in subsection 25 (2) or(b) a piece of equipment is or was previously listed in the table required by section 23 and the
Director is of the opinion that discharges from the piece of equipment may cause anadverse effect
Notification of change 27 (1) Subject to subsection (2) no later than 30 days after a change mentioned in section
25 or 26 is made at a metal finishing facility the registered person shall ensure that a provincialofficer is notified in writing of the change
(2) Subsection (1) does not apply if the thing affected by the change is a thing which maydischarge or from which may be discharged a registered contaminant in an amount that isnegligible
(3) The notification required by subsection (1) shall include the following information1 A description of the change including a description of the equipment methods and
ventilation systems affected by the change and the date that the change was made2 One of the following with respect to the change mentioned in paragraph 1
i An explanation of how the change meets the criteria set out in subsection 25 (2)ii If the change was authorized by a notice given under subsection 25 (4) the reference
number of the noticeiii If the change was required by an order given under section 26 the reference number
of the order
182Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
PART VI ndash COMPLAINTS ANNUAL SUMMARY REPORTS AND RECORDS
Complaint procedure 28 (1) A registered person shall ensure that the following steps are taken to properly
respond to each complaint that relates to the discharge of a contaminant into the air from ametal finishing facility
1 A prompt response is made to the person who made the complaint unless the personrequests that a response not be made or fails to provide contact information
2 Action is taken to remedy the cause of the complaint3 A written record of the complaint is prepared that includes the following information
i A description of the complaintii The date and time that the complaint was receivediii The date time and suspected cause of the incident to which the complaint relates
including whether any outdoor activities may have given rise to the complaintiv Ambient temperature at the time of the incident to which the complaint relatesv The approximate wind direction and wind speed at the time of the incident to which
the complaint relatesvi The general weather conditions at the time of the incident to which the complaint
relatesvii A description of any actions taken to address the incident to which the complaint
relates and the date each action was completedviii A description of any actions taken to prevent a future incident similar to the incident to
which the complaint relates and the date each action was completed(2) If a complaint is made that relates to a matter addressed in this industry standard the
registered person shall ensure that the Ministryrsquos Spills Action Centre is notified of the complaintas soon as practicable after the complaint is made
(3) No later than five days after notification is required to be given under subsection (2) theregistered person shall ensure that the following information is submitted in writing to a provincial officer
1 A description of the complaint2 The time and date of the incident to which the complaint relates3 A description of any actions taken or that will be taken to address the incident to which the
complaint relates4 The dates on which each action mentioned in paragraph 3 was completed or is
anticipated to be completed
Summary reports 29 (1) On and after January 1 2019 a registered person shall ensure that annual
summaries are prepared and reviewed in accordance with this section (2) No later than March 31 each year the following summaries shall be prepared and the
information therein shall pertain to the preceding calendar year 1 A table labelled ldquoImplementation Summary Tablerdquo that for the calendar year sets out
i A summary of the provisions of this industry standard that apply to the metal finishingfacility in accordance with section 2
ii For each provision mentioned in subparagraph i
183Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
A an indication of the date on which the provision applies to the metal finishingfacility and
B if compliance with the provision has been achieved an indication of the date onwhich compliance was achieved
2 A summary that for the calendar year sets out changes made to ventilation systems atthe metal finishing facility and summarizes the information that was required to beupdated in accordance with subsections 19 (2) and (3)
3 If during a calendar year an action is required to be taken in accordance with clause 20(7) (a) a description of each action taken during the year to ensure fugitive emissions ofregistered contaminants are adequately captured a summary of the information that wasrequired to be recorded in accordance with subsections 20 (7) (b) and a summary of allactions taken to date and actions still to be taken
4 A summary that for the calendar year sets out changes made to the OperatingParameter Summary Table and summarizes the information that was required to beupdated in accordance with subsection 6 (11)
5 A record labelled ldquoSummary of Deviationsrdquo that for the calendar year sets outi a summary of the information required by subsections 8 (2) 13 (2) and (4) and
paragraph 6 of subsection 16 (4)ii an indication of any changes in the number of deviations from the summary of the
previous yeariii the number of times an event that caused one or more deviations occurred at the
facility during the calendar yeariv an indication of whether any of the events mentioned in subparagraph iii were of
particular concernv an indication of whether the number of events mentioned in subparagraph iii suggest
a recurring issue both in respect of the calendar year and in respect of previouscalendar years and
vi an explanation of any actions taken to address the events mentioned in subparagraphiii
6 A summary that for the calendar year sets outi the number of notifications given under subsection 14(1)ii for each notification mentioned in subparagraph i a summary of the plan that was
required to be prepared by subsection 14 (2)iii for each plan mentioned in subparagraph ii a summary of the actions taken and the
dates by which remaining actions are anticipated to be taken7 A table labelled ldquoPerformance Summary Tablerdquo that for the calendar year sets out
i a summary of all notifications required to be given under subsections 15 (5) and 15(6)
ii an indication of whether a notice has been given to the metal finishing facility undersubsections 20 (1) or 25 (4) and
iii an indication of whether an order has been given to the metal finishing facility undersubsections 6 (10) or 11 (7) or section 26
8 A summary that for the calendar year sets out changes made to the Inspection andMaintenance Summary Table and summarizes the information that was required to beupdated in accordance with subsection 11(8)
9 A table labelled ldquoAnnual Summary of Changes to Source Informationrdquo that for thecalendar year sets out the following information
184Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
i Column 1 Each piece of equipment at the metal finishing facility that discharges orfrom which may be discharged a registered contaminant
ii Column 2 Opposite each piece of equipment required to be set out by paragraph 1each local exhaust ventilation system and general exhaust ventilation associated withthe piece of equipment
iii Column 3 Opposite each piece of equipment required to be set out by paragraph 1each method that prevents minimizes or reduces the discharge of a registeredcontaminant from the piece of equipment
iv Column 4 Opposite each piece of equipment required to be set out by paragraph 1an indication if the information in Columns 1 2 or 3 has changed from information setout in the previous calendar year
10 A table labelled ldquoComplaint Summary Tablerdquo that sets out the total number of complaintsdescribed in subsection 28 (1) that have been received by the metal finishing facility in thecalendar year and compares the number to the number of complaints received by themetal finishing facility in the previous calendar year
11 On and after January 1 2020 a comparison of the total rectifier capacity of the metalfinishing facility during the year for which the summary report is being prepared to the totalrectifier capacity of the metal finishing facility on December 31 2019
(3) No later than March 31 each year the highest-ranking individual at the metal finishingfacility shall certify in writing that the summaries required by paragraphs 1 2 3 4 5 6 7 10and 11 of subsection (2) have been prepared in accordance with this industry standard and thatthe information contained in the summaries is
(a) accurate and complete and(b) true to the best of his or her knowledge(4) The summary tables required by paragraphs 1 and 7 of subsection (2) shall be(a) made available for examination by any person without charge by ensuring it is posted
and available on the website for the metal finishing facility or by making it available duringregular business hours at the place to which the report relates and
(b) given without charge to any person within 15 days after the person requests it
Records 30 (1) A registered person shall ensure that each record required in accordance with
section 2 of this industry standard is retained at the metal finishing facility for at least five yearsand made available to a provincial officer or Director upon request as soon as practicable
(2) A person required to make a record available under subsection (1) shall make it availablein a form approved by the Director including if required by the Director an electronic format specified by the Director
(3) In addition to the records mentioned in subsection (1) a registered person shall ensurethat each document relating to the recommendations of the manufacturer for each device at the metal finishing facility with respect to the use operation and maintenance of the device is retained for the period during which the device is used or operated
185Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Appendix 5-A All Contaminants
Item Column 1
CAS No
Column 2
Contaminant
1 7440-47-3 Chromium Compounds (Hexavalent)
2 7440-02-0 Nickel And Nickel Compounds
Appendix 5-B Chromium compounds (hexavalent )
Item Column 1
CAS No
Column 2
Contaminant
1 7440-47-3 Chromium Compounds (Hexavalent)
Appendix 5-C Nickel and nickel compounds
Item Column 1
CAS No
Column 2
Contaminant
1 7440-02-0 Nickel And Nickel Compounds
Record of Publications for Metal Finishers - Industry Standard
Tracking Date Publishing Minister
Version 20
Metal Finishers - Industry Standard
Created July 27 2016 Murray
Version 10
Metal Finishers - Industry Standard
Created March 8 2016 Murray
186Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
CHAPTER 6 ndash PETROLEUM REFINING ndash INDUSTRY STANDARD
Version 20 Created February 27th 2018
Preamble bull This technical standard is an industry standard as defined in section 1 of O Reg 41905
bull With respect to facilities this industry standard applies to every facility that is part of a classidentified by one or more of the following NAICS codes 324110 (Petroleum Refineries) and 324190(Other Petroleum and Coal Product Manufacturing) If the activities identified by NAICS code412110 (Petroleum Product Wholesaler-Distributors) take place on the same property as activitiesidentified by NAICS code 324110 (Petroleum Refineries) or 324190 (Other Petroleum and CoalProduct Manufacturing) then the facility is part of two or more classes that are identified by NAICScodes and this industry standard applies to all of those classes See also section 4 of O Reg41905 regarding properties that are deemed to be a single property
bull For clarity if a facility is part of a class identified by NAICS code 412110 (Petroleum ProductWholesaler-Distributors) and not on the same property as a facility that is part of a class identified byNAICS code 324110 (Petroleum Refineries) or 324190 (Other Petroleum and Coal ProductManufacturing) this industry standard does not apply to the facility
bull With respect to contaminants this industry standard applies to contaminants listed in Appendix 6shyA
bull Each source of contaminant associated with NAICS codes 324110 324190 and if on the sameproperty 412110 that discharges a contaminant mentioned in the above bullet has been consideredin development of this industry standard As such a person that meets the criteria set out insubsection 42 (1) or subsection 44 (1) of O Reg 41905 is in general exempt from Part II of theRegulation in respect of the facility and contaminant(s) for which it is registered In other wordsthere is no need to model in a facilityrsquos Emission Summary and Dispersion Modelling reportdischarges of a registered contaminant from any source of contaminant associated with NAICScodes 324110 324190 and if on the same property 412110 (For more information please see theIntroduction to the Technical Standards Publication)
bull In accordance with subsection 38 (3) of O Reg 41905 compliance with this industry standard inaccordance with subsection 42 (5) or subsection 44 (3) of O Reg 41905 may reduce theregulatory burden applicable to facilities in this class
bull This standard contains requirements that relate to sources of contaminant associated with thefollowing
bull storage vesselsbull equipment leaksbull sewage treatment operationsbull truck and railcar product loading racks and marine vessel loading berths
187Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
bull For this industry standard with respect to benzene the publication of this industry standardindicates that the following criteria of paragraph 3 of subsection 38 (1) of O Reg 41905 are met
(a) with respect to at least two facilities located in Ontario to which this standard applies it is nottechnically feasible to comply with section 20 of O Reg 41905 and
(b) compliance in accordance with subsection 42 (5) of O Reg 41905 with this standard
(i) is technically and economically feasible with respect to at least one facility located inOntario to which this industry standard applies
(ii) will permit efforts that would otherwise be made to comply with section 19 or 20 of O Reg41905 to be put to better use to protect the natural environment having regard to clause(a) and
(iii) including this industry standard in the ldquoTechnical Standards to Manage Air Pollutionrdquo ismore efficient than having the Director consider separate requests under section 32 of OReg 41905 to set site-specific standards for the contaminant that would otherwise applyto facilities in the class
188Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
CONTENTS
PART I ndash GENERAL 1 Definitions2 Application3 Leak Measurement Instrumentation
PART II ndash PERFORMANCE 4 Closed systems5 Flare6 Air pollution control devices7 Requirement to detect leaks8 Notification ndash performance requirements
PART III ndash STORAGE VESSELS 9 Storage vessels ndash identification10 Storage vessels - application11 Floating roof - requirement to float12 Internal floating roof ndash rim seal requirements13 External floating roof ndash rim seal requirements14 Floating roof deck fittings15 Deck covers ndash requirement to be closed16 Floating roof - visual inspection17 Storage vessels - OGI inspection18 Floating roof - seal gap inspection19 Storage vessel repair20 Requirement to notify ndash recurring repairs21 Storage vessels in benzene service ndash general record22 Storage vessel inspection record23 Rim seal gap report ndash storage vessels
PART IV ndash AIR EMISSIONS FROM INDUSTRIAL SEWAGE 231 Application sections 24 and 25 24 Primary oil-water separators ndash requirement selection25 Primary oil-water separators ndash monitoring and control requirements26 Primary oil-water separators floating roof ndash requirement to float27 Primary oil-water separators floating roof ndash rim seal gap inspection28 Primary oil-water separator ndash OGI inspection29 Primary oil-water separator repair30 Primary oil-water separator record - general31 Primary oil-water separator inspection record32 Rim seal gap report ndash Primary oil-water separator33 Drains and maintenance access points ndash measurement and control requirements34 Drain and maintenance access point record
PART V ndash PRODUCT LOADING 35 Benzene-containing product loading operations ndash application36 Cargo tank loading operations ndash general operating requirements37 Vapour-tight cargo tanks
PART VI ndash LEAK DETECTION AND REPAIR 38 Component identification39 Component leak survey ndash general
189Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
40 Component leak survey ndash assessment and measurement of leaks41 Component leak survey plan42 Additional leak measurements - pumps compressors and pressure relief devices43 Leaks - deviations and repair44 Delay of repair list45 Re-measurement following component repair or replacement46 Component replacement47 Leaking components - annual calculations48 Records - component leak survey49 Records ndash additional leak measurements
PART VII ndash OPERATION 50 Technology requirements ndash open-ended valves51 Technology requirements ndash surge control vessels and bottoms receivers52 Operating parameter summary table53 Measurement of operating parameters54 Phase-in for new air pollution control devices
PART VIII ndash REQUIREMENT TO CONTINUE THE USE OF METHODS TO MANAGE EMISSIONS 55 Identifying managed sources56 Requirement to continue the management of sources57 Changes to managed sources58 Specified source management59 Notification of changes to management of sources
PART IX ndash AMBIENT MONITORING 60 Ambient monitoring - benzene61 Benzene measurements baseline62 Statistical analysis of benzene measurements63 Notification ndash ambient monitoring
PART X ndash COMPLAINTS RECORDS AND REPORTING 64 Complaints procedure65 Annual summary reports66 Public reporting ndash ambient monitoring67 Records
Appendix 6-A All Contaminants Appendix 6-B Benzene Appendix 6-C Benzo(a)pyrene Appendix 6-D Portable Gas Detector - Methodology and Instrumentation Appendix 6-E Optical Gas Imaging - Methodology and Instrumentation Appendix 6-F Fixed Leak Detection System - Methodology and Instrumentation
190Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
PART I ndash GENERAL
Definitions 1 (1) For the purposes of this industry standard for petroleum refining facilities
ldquoActrdquo means the Environmental Protection Act
ldquoair pollution control devicerdquo means a device that removes contaminants from a gaseous stream and includes a carbon adsorber a thermal oxidizer a flare a condenser an absorber and an incinerator
ldquobenzene-containing productrdquo means a substance produced by a petroleum refining facility thatcontains two per cent or more benzene by weight and includes gasoline
ldquobottoms receiverrdquo means a tank that collects distillation bottoms ldquocarbon adsorberrdquo means an air pollution control device which uses a bed of activated carbon to
adsorb contaminants including VOCs ldquocargo tankrdquo means a container including all associated pipes and fittings that is designed to
contain liquid product and is constructed to be part of a transportation system including a truckrailcar or marine vessel
ldquoCAS Nordquo has the same meaning as in subsection 1 (1) of O Reg 41905 ldquocatalytic oxidizerrdquo means a technology that passes a gas over a support material coated with a
catalyst that promotes oxidation of organic material in the gas ldquoclosed systemrdquo means a system of piping ductwork and connections that conveys a gas or vapour
from a point of generation to another location without discharging the gas or vapour into the air ldquocomponentrdquo means an apparatus that is part of an industrial process and includes a compressor a
pump a valve a pressure relief device a sample point an instrumentation system an agitatorand a connector
ldquocooling water effluentrdquo has the same meaning as in O Reg 53793 ldquoconnectorrdquo means a flanged screwed or other joined fitting used to connect two pipes or a pipe and
a piece of equipment For the purpose of this industry standard joined fittings welded completelyaround the circumference of the component interface are not considered connectors
ldquodeck coverrdquo means a device that stops contaminants from being discharged to the air from an opening on a floating roof deck
ldquodeck fittingrdquo means a piece of equipment that is inserted through an opening in a floating roof deckand includes a sample port a vacuum breaker a deck leg an access hatch a deck drain anaccess ladder well a fixed-roof support column an unslotted guidepole and a slotted guidepole
ldquodistillation bottomsrdquo is the portion of crude oil raw material that is discharged from the bottom of thedistillation column
ldquodistillation columnrdquo is a column that heats and separates crude oil raw material into componentswith differing boiling points
ldquodrainrdquo means a work that collects and transmits sewage to a sewer line ldquoexisting storage vesselrdquo means a storage vessel that
(a) was installed at a petroleum refining facility before January 1 2018 and(b) has not undergone a major modification after January 1 2018
ldquoexternal floating roofrdquo means a floating roof located in a storage vessel or an oil-water separatorwithout a fixed roof
ldquoflarerdquo means a combustion device that uses an uncontrolled volume of air to burn gases A flareincludes the foundation flare tip structural support burner igniter flare controls air injection orsteam injection systems flame arrestors and the flare gas header system
191Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 ldquofixed leak detection systemrdquo means a permanently located system of sensors that are electrically
linked to an analyzer and an electronic data acquisition system For example a fixed leakdetection system may be located near a component sample the air at regular time intervals andanalyze and record the concentration of VOCs discharged to the air from the leaking component
ldquogasolinerdquo means a petroleum distillate or a petroleum distillate and alcohol blend having a Reid vapour pressure of 40 kilopascals or greater that may be used as a fuel for an internal combustion engine
ldquoinaccessible componentrdquo means a component that is located (a) at least two metres above a permanently available support surface(b) in such a manner that scaffolding or a harness is required in order to access the component
or(c) in such a manner that the component is made inaccessible by a protective cover or insulation
ldquointernal floating roofrdquo means a floating roof located in a storage vessel or an oil-water separator witha fixed roof
ldquoloading berthrdquo means the loading arms pumps meters shutoff valves relief valves and otherpiping and valves used to load product into a marine vessel cargo tank
ldquoloading rackrdquo means the loading arms pumps meters shutoff valves relief valves and other piping and valves used to load product into a truck or railcar cargo tank
ldquolow emission valverdquo means a valve that minimizes the discharge of contaminants from the valve tothe natural environment
ldquolow emission valve packingrdquo means a material that minimizes the discharge of contaminants from a valve to the natural environment
ldquoliquid-mounted rim sealrdquo means a rim seal that is foam-filled or liquid-filled and is designed to be in contact with liquid stored in a storage vessel or an oil-water separator
ldquomaintenance access pointrdquo means an access point to a sewer line sometimes referred to as a person-hole junction box maintenance hole manhole or grate
ldquomajor modificationrdquo means a modification to a piece of equipment the capital cost of which is atleast 50 per cent of the capital cost of replacing the equipment with a piece of equipment of thesame size
ldquomechanical shoe rim sealrdquo means a rim seal consisting of (a) a band of metal or other suitable material that is in sliding contact with the wall of a storage
vessel or oil-water separator and which extends into the liquid stored in the vessel orseparator and
(b) a fabric seal to close the annular space between the band and the floating roof deck of thestorage vessel or oil-water separator
Minister means the Minister of the Environment and Climate Change or such other member of theExecutive Council as may be assigned the administration of this Act under the Executive Council Act
Ministry means the ministry of the Minister ldquooil-water separatorrdquo means a works in a sewage treatment system that separates free oil from
sewage and consists of one or more of each of the following 1 Influent flumes or other inlet conduits2 Separation zones3 Effluent flumes or other outlet conduits4 Ancillary components which may include
i Forebaysii Skimmersiii Bafflesiv Weirs
192Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 v Grit chambersvi Sludge hoppersvii Bar screens
ldquoopen-ended valverdquo means a valve except a pressure relief valve having one side of the valve sealin contact with process fluid and one side open to the air either directly or through open piping
ldquoOGI instrumentrdquo means an instrument that makes emissions that may otherwise be invisible to the naked eye visible through the use of optical gas imaging
ldquoprimary oil-water separatorrdquo means an oil-water separator that separates free oil from sewage that (a) has not passed through an oil-water separator upstream and(b) is not solely cooling water effluent storm water effluent or a combination of cooling water
effluent and storm water effluentldquoprimary rim sealrdquo means
(a) a rim seal on a floating roof that has only one rim seal or(b) the lower rim seal on a floating roof that has two rim seals
ldquopetroleum refining facilityrdquo means a facility which is part of a class identified by one or more of the following NAICS codes 324110 and 324190 A petroleum refining facility includes activitiesdescribed by NAICS code 412110 if the activities take place on the same property as the activitiesdescribed by NAICS codes 324110 or 324190
ldquoportable gas detectorrdquo means a handheld instrument that when passed over a leaking componentmeasures the concentration of the gas leaking from the component
ldquoproductrdquo means a substance produced by a petroleum refining facility that is intended to be sold ortransferred
ldquoregistered contaminantrdquo means a contaminant that is discharged into the air from a facility if a person is registered in respect of this industry standard the facility and the contaminant
ldquoregistered personrdquo means a person that is registered on the Ministryrsquos Technical Standards Registry ndash Air Pollution in respect of this industry standard a petroleum refining facility and one ormore contaminants listed in Appendix 6-A
ldquoresidence timerdquo means the average amount of time that a gas spends in a furnace and is calculatedby dividing the volume of the furnace by the volumetric flow rate of the gas through the furnace
ldquorim sealrdquo means a device attached to the rim of a floating roof deck that spans the annular space between the deck and the wall of the storage vessel
ldquosecondary rim sealrdquo means the upper rim seal on a floating roof that has two rim seals ldquoseparation zonerdquo means the structure in an oil-water separator in which the separation of free oil
from sewage primarily takes place It may also be known as a separation or separator bayseparation or separator tank separation or separator chamber separation or separatorcompartment separation or separator channel separation or separator cell or separation orseparator basin In some oil-water separators the separation zone is preceded by a forebay
ldquosewer linerdquo means a work used to collect and transmit industrial sewage to a sewage treatmentsystem and includes a lateral trunk line a branch line a ditch and a channel
ldquostorage vesselrdquo means a tank used to store liquid petroleum liquid petroleum derivatives or liquidproduct
ldquostorm water effluentrdquo has the same meaning as in O Reg 53793 ldquosurge control vesselrdquo means a vessel that is used to manage flow rates in a process ldquothermal oxidizerrdquo means a device in which a combustible waste gas passes over or around a burner
flame into a chamber where oxidation of the waste gas is completed ldquounsafe componentrdquo means a component that if assessed for leaks is likely to
(a) expose personnel performing the assessment to imminent hazard from temperature pressureor explosive process conditions or
(b) lead to other dangerous circumstances as defined by the Occupational Health and Safety Act
Ontario Ministry of the Environment and Climate Change 193
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 ldquovapour-mounted rim sealrdquo means a rim seal that is designed to not be in contact with liquid stored
in a storage vessel or oil-water separator and includes foam-filled seals and flexible wiper seals ldquovolatile organic compoundrdquo (ldquoVOCrdquo) means an organic compound the composition of which makes
it possible for the compound to evaporate under normal atmospheric conditions of temperatureand pressure (2) For the purpose of this industry standard a floating roof inside a storage vessel with a
geodesic dome will be considered to be an internal floating roof (3) For the purpose of this industry standard a component surge control vessel or bottoms
receiver is in benzene service if (a) before January 1 2025 the component surge control vessel or bottoms receiver may contain
or come in contact with a liquid or gas that contains at least 20 per cent benzene by weightand
(b) on and after January 1 2025 the component surge control vessel or bottoms receiver maycontain or come in contact with a liquid or gas that contains at least 08 per cent benzene byweight
(4) For the purpose of this industry standard a storage vessel is in benzene service if(a) before January 1 2025 the storage vessel stores liquid that has a benzene concentration of at
least 20 per cent by weight and(b) on and after January 1 2025 the storage vessel stores liquid that has a benzene
concentration of at least 10 per cent by weight(5) For the purpose of this industry standard a component is in heavy liquid service if thecomponent contains a fluid(a) that is not in a gaseous state at operating conditions and(b) in which the percentage of pure organic compounds that have a vapour pressure of greater
than 03 kPA at 20oC is less than 20 per cent by weight(6) In this industry standard a reference to the Director means(a) the Director appointed under section 5 of the Act in respect of the section of this industry
standard in which the reference appears(b) [Revoked] or(c) if no Director described in clause (a) has been appointed in respect of a provision any Director
appointed under section 5 of the Act in respect of section 271 or paragraphs 2 or 3 ofsubsection 11 (1) of O Reg 41905
Application 2 (1) This industry standard applies in accordance with subsections (2) and (3) to a person who
is registered on the Ministryrsquos Technical Standards Registry ndash Air Pollution in respect of (a) this industry standard(b) a petroleum refining facility and(c) one or more of the contaminants listed in Appendix 6-A(2) If the person mentioned in subsection (1) is registered with respect to a petroleum refining
facility and one or more of the contaminants listed in an Appendix set out in Column 1 of Table 6-2 the sections set out opposite the Appendix in Column 2 of Table 6-2 apply in respect of the person
(3) A person mentioned in subsection (1) is required to comply with the sections of this industrystandard that apply to the person in accordance with subsection (2) on or before the date the person registers on the Ministryrsquos Technical Standards Registry ndash Air Pollution unless a different date is specified in this industry standard
TABLE 6-2 Application Item Column 1
Appendix Column 2 Applicable Sections
194Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1 Appendix
Column 2 Applicable Sections
1 Appendix 6-A All Contaminants 1 2 52 to 59 64 65 67 2 Appendix 6-B Benzene 3 to 51 60 to 63 66 3 Appendix 6-C Benzo(a)pyrene -
Leak Measurement Instrumentation 3 A registered person shall ensure that(a) if this industry standard requires the use of a portable gas detector the detector meets the
criteria set out in subsection 2 (1) of Appendix 6-D and is used in a manner set out in section 3of Appendix 6-D
(b) if this industry standard requires the use of an OGI instrument the instrument meets thecriteria set out in section 1 of Appendix 6-E and is used in a manner set out in section 2 ofAppendix 6-E and
(c) if this industry standard requires the use of a fixed leak detection system the system meetsthe criteria set out in section 1 of Appendix 6-F
PART II ndash PERFORMANCEClosed systems
4 (1) Subject to subsections (2) and (3) where this industry standard requires benzene to beconveyed in a manner set out in this section the registered person shall ensure that benzene isconveyed in a closed system to one or more of the following
1 A flare that meets the requirements set out in section 52 An air pollution control device other than a flare that meets the requirements set out in
section 63 A process that uses the benzene in a manner that
i recovers the benzeneii incorporates the benzene into a product to be sold or transferrediii converts the benzene into a substance that is not benzene oriv is similar to the manner in which another substance is used in the process
(2) Benzene that is required to be conveyed to a thermal oxidizer or catalytic oxidizer inaccordance with paragraph 2 of subsection (1) does not need to be conveyed to the air pollution control device if the air pollution control device is being repaired or maintained and the total number of hours that the air pollution control device was repaired and maintained in the preceding 12-month period does not exceed 240 hours
(3) Benzene that is required to be conveyed to a process in accordance with paragraph 3 ofsubsection (1) does not need to be conveyed to the process if the process is being repaired or maintained and the total number of hours that the process was repaired and maintained in the preceding 12-month period does not exceed 240 hours
(4) When calculating the number of hours for the purpose of subsections (2) and (3) the timewhen a thermal oxidizer catalytic oxidizer or process is being repaired or maintained does not need to be included in the total number of hours if benzene is not being conveyed to the air pollution device or process during the time
(5) The registered person shall ensure that each time an air pollution control device or processmentioned in subsection (2) or (3) is repaired or maintained the following information is recorded
195Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 1 The date of the repair or maintenance2 The duration of the repair or maintenance3 A description of the repair or maintenance4 The position title of the personnel who assigned an individual to complete the repair or
completed the maintenance5 An indication of whether benzene is being conveyed to the air pollution device or process
during the repair or maintenance(6) If the thing from which the benzene is being conveyed in the closed system required by
subsection (1) has a vent the registered person shall ensure that the vent is closed
Flare 5 On and after January 1 2020 a flare mentioned in paragraph 1 of subsection 4 (1) shall have
a pilot flame present when a substance is being conveyed to the flare
Air pollution control devices 6 An air pollution control device mentioned in paragraph 2 of subsection 4 (1) shall meet at least
one of the following criteria 1 The air pollution control device shall reduce the discharge of benzene to the air by at least 95
per cent on a mass basis2 The air pollution control device shall not discharge VOCs to the air in a concentration of
greater than 20 ppm by volume on a dry basis corrected to three per cent oxygen3 If the air pollution control device is a thermal oxidizer the gas in the thermal oxidizer shall be
maintained at a temperature of at least 760oC for a residence time of at least 075 seconds4 If the air pollution control device is a catalytic oxidizer the gas in the catalytic oxidizer shall be
maintained at a temperature of at least 400oC
Requirement to detect leaks 7 A registered person shall ensure that each component leak survey performed under subsection
39 (1) detects leaks from every leaking component that is part of the component leak survey
Notification ndash performance requirements 8 (1) The registered person shall ensure that as soon as practicable a provincial officer is
notified in writing of any contravention of sections 4 or 7 (2) No later than 30 days after notification is required to be given under subsection (1) the
registered person shall ensure that the following information is submitted in writing to a provincialofficer
1 The date and time of the contravention2 The details of the contravention including any measured or calculated values relating to an
exceedence of a limit3 An explanation of suspected cause of the contravention including the suspected cause of
each exceedence of a limit if any4 A description of any steps taken or that will be taken to prevent minimize or reduce the risk
of future contraventions
PART III ndash STORAGE VESSELSStorage vessels ndash identification
9 (1) A registered person shall ensure that each storage vessel at the petroleum refining facilityis identified and recorded in accordance with this section
196Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 (2) A record shall be made that sets out the following information for each storage vessel at the
petroleum refining facility 1 The identification number of the storage vessel2 A description of the liquid contained in the storage vessel including the nominal percent by
weight of benzene in the liquid during the previous 12-month period(3) A list shall be prepared that identifies each storage vessel that meets the following criteria1 The storage vessel has a design capacity of greater than 75 cubic metres2 The storage vessel is designed to operate at an absolute internal pressure of less than 205
kilopascals3 The storage vessel in accordance with subsection (4) is was or is anticipated to be in
benzene service(4) In determining if the criterion mentioned in paragraph 3 of subsection (3) is met the following
information shall be considered 1 The concentration of benzene in the liquid stored in the storage vessel for example the
nominal percent by weight of benzene in the liquid2 The average concentration of benzene in the liquid stored in the storage vessel in the previous
12-month period3 The anticipated concentration of benzene in the liquid to be stored in the storage vessel based
on process information(5) The list required by subsection (3) shall be updated in accordance with the following rules1 No later than 30 days after a change is made at the petroleum refining facility that results in a
storage vessel meeting the criteria set out in subsection (3) the storage vessel shall be addedto the list required by subsection (3)
2 If a change is made at the petroleum refining facility that results in a storage vessel no longermeeting the criteria set out in subsection (3) the registered person shall ensure that theDirector and a provincial officer are notified of the change at least 30 days before the storagevessel is removed from the list required by subsection (3)
3 If on or after January 1 2025 a storage vessel meets the criteria set out in subsection (3) thestorage vessel shall be added to the list required by subsection (3)
(6) The notification required by paragraph 2 of subsection (5) shall include all informationrelevant to demonstrating that the storage vessel no longer meets the criteria set out in subsection(3)
(7) No later than January 1 2023 a record shall be prepared that sets out each storage vessel atthe petroleum refining facility that is anticipated to meet the criteria set out in subsection (3) on orafter January 1 2025
(8) No later than 60 days after a change is made at the petroleum refining facility that would affectthe information in the record required by subsection (2) the record shall be updated to reflect the change
Storage vessels - application 10 (1) Subject to subsection (4) on and after January 1 2018 a registered person shall ensure
that each storage vessel identified on the list required by subsection 9 (3) meets at least one of the following criteria
1 Subject to subsection (2) the storage vessel shall be equipped with an internal floating roofthat meets the requirements set out in sections 12 and 14
2 Subject to subsection (3) the storage vessel shall be equipped with an external floating roofthat meets the requirements set out in sections 13 and 14
3 Benzene which would otherwise be discharged from the storage vessel to the air shall beconveyed in a manner set out in section 4
(2) The requirements set out in sections 12 and 14 do not apply to an existing storage vesselequipped with an internal floating roof
197Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 (3) The requirements set out in sections 13 and 14 do not apply to an existing storage vessel
equipped with an external floating roof unless (a) the date is on or after January 1 2020 and the vessel stores liquid which has an annual
average benzene concentration of more than 50 per cent by weight(b) the date is on or after January 1 2025 and the vessel stores liquid which has an annual
average benzene concentration of more than four per cent by weight or(c) the date is on or after January 1 2029(4) Subsection (1) does not apply to an existing storage vessel equipped with a fixed roof unless(a) the date is on or after January 1 2020 and the vessel stores liquid which has an annual
average benzene concentration of more than 50 per cent by weight(b) the date is on or after January 1 2025 and the vessel stores liquid which has an annual
average benzene concentration of more than four per cent by weight or(c) the date is on or after January 1 2029
Floating roof - requirement to float 11 (1) A registered person shall ensure that for each storage vessel that is required to comply
with paragraph 1 or 2 of subsection 10 (1) the floating roof floats on the surface of the liquid stored in the storage vessel
(2) As soon as practicable after a contravention of subsection (1) the registered person shallensure that at least one of the following actions are taken
1 The storage vessel shall be filled so that the roof floats on the surface of the liquid stored in thestorage vessel as required by subsection (1)
2 The storage vessel shall be emptied of liquid(3) A registered person shall ensure that the following information is recorded with respect to
each contravention of subsection (1) 1 The identification number of the storage vessel2 The date and time that the floating roof was identified as not floating3 The date and time that an action required by subsection (3) was taken
Internal floating roof ndash rim seal requirements 12 An internal floating roof mentioned in paragraph 1 of subsection 10 (1) shall have(a) a liquid-mounted rim seal(b) a mechanical shoe rim seal or(c) a vapour-mounted rim seal and a secondary rim seal
External floating roof ndash rim seal requirements 13 (1) An external floating roof mentioned in paragraph 2 of subsection 10 (1) shall have(a) a liquid-mounted rim seal and a secondary rim seal or(b) a mechanical shoe rim seal and a secondary rim seal(2) The mechanical shoe rim seal mentioned in clause (1) (b) shall meet the following criteria1 The top of the mechanical shoe rim seal shall be a minimum of 61 centimetres above the
surface of the liquid stored in the storage vessel2 The band of material of the mechanical shoe rim seal that is in sliding contact with the storage
vessel shall extend into the liquid stored in the storage vessel
Floating roof deck fittings
198Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 14 (1) The requirements set out in this section apply with respect to a floating roof mentioned in
paragraphs 1 and 2 of subsection 10 (1) and subparagraph 3 i of subsection 25 (1) (2) The lower edge of each deck fitting on a floating roof shall be below the surface of the liquid
stored in the storage vessel or primary oil-water separator unless the deck fitting is an automaticbleeder vent vacuum breaker vent or rim space vent
(3) Each automatic bleeder vent vacuum breaker vent and rim space vent shall be equippedwith
(a) a lid with a gasket(b) a pallet with a gasket or(c) a flapper with a gasket(4) The space between the floating roof deck and each fixed roof support column shall be filled by
a flexible fabric sleeve seal or covered by a gasketed deck cover (5) Each sample well and deck drain shall be covered by(a) a slit fabric seal that covers at least 90 per cent of the sample well or deck drain or(b) a gasketed deck cover(6) The space between the floating roof deck and each guidepole shall be filled by a pole wiper(7) Each slotted guidepole shall have(a) a pole float where the height of the pole float is at or above the height of the pole wiper or(b) an internal pole sleeve(8) Each unslotted guidepole shall have a gasketed cap on the top of the guidepole(9) With respect to a deck fitting that is not mentioned in subsections (3) to (8) the space
between the deck fitting and the floating roof deck shall be covered by a gasketed deck cover (10) A gasketed deck cover that covers an access hatch or gauge float well shall be bolted or
fastened when closed
Deck covers ndash requirement to be closed 15 (1) Subject to subsection (2) the registered person shall ensure that each deck cover
required by section 14 is closed when the storage vessel contains liquid (2) Subsection (1) does not apply if the deck cover is required to be open to(a) gauge the liquid level in the storage vessel or(b) take a sample of the liquid in the storage vessel(3) Subject to subsection (4) the registered person shall ensure that each lid pallet and flapper
mentioned in subsection 14 (3) is closed when the storage vessel contains liquid (4) Subsection (3) does not apply if the lid pallet or flapper is required to be open to relieve
excess pressure or vacuum in the storage vessel (5) The pressure above or below which is to be considered excess for the purpose of subsection
(4) shall be based on the recommendation of a professional(6) The source of the professional recommendation mentioned in subsection (5) shall be one of
the following documents 1 An operating and maintenance manual provided by a manufacturer of storage vessels2 Written instructions provided by a supplier of storage vessels3 A letter from a manufacturer mentioned in paragraph 1 or supplier mentioned in paragraph 2
setting out the recommendation4 A letter from a professional engineer setting out the recommendation the rationale for the
recommendation and a description of the relevant experience with respect to the
199Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 recommendation being made The engineer must have relevant experience with respect to pressure or vacuum in storage vessels
Floating roof - visual inspection 16 (1) On and after January 1 2018 a registered person shall ensure that each storage vessel
identified on the list required by subsection 9 (3) that is required to comply with paragraph 1 or 2 ofsubsection 10 (1) is visually inspected in accordance with this section to determine if any of the defects set out in subsection (7) are present
(2) The inspection required by subsection (1) shall include an inspection of each floating roofdeck each deck fitting and each rim seal
(3) The inspection required by subsection (1) shall be performed from the top of the floating roofeach time a storage vessel is empty
(4) If during a five-year period a storage vessel mentioned in subsection (1) that has an externalfloating roof has not been inspected under this section the inspection required by subsection (1)shall be performed from the top of the floating roof no later than 30 days after the end of the five-year period
(5) Subject to subsection (6) if during a five-year period a storage vessel described in subsection(1) that has an internal floating roof has not been inspected under this section the inspectionrequired by subsection (1) shall be performed no later than 30 days after the end of the five-yearperiod by observing the floating roof deck each deck fitting and each rim seal through an openingin the fixed roof
(6) The inspection mentioned in subsection (5) does not need to determine if the defects set outin paragraphs 5 to 9 of subsection (7) are present
(7) The defects mentioned in subsection (1) include the following1 Liquid on the floating roof of the storage vessel2 A hole or tear in the rim seal of the storage vessel3 A detachment of any part of the rim seal from either of two surfaces from which the rim seal is
intended to minimize air emissions that isi greater than 30 centimetres in length andii visible from a distance of three metres or more
4 The roof is not floating on the surface of the liquid as required by subsection 11 (1)5 An opening for a fixed roof support column is not equipped with a fabric sleeve or gasketed
deck cover6 A sample well is not equipped with a slit fabric seal7 A guidepole does not have a pole wiper pole float internal pole sleeve or gasketed cap as
applicable8 The lower edge of a deck fitting other than an automatic bleeder vent vacuum breaker vent or
rim space vent is not below the surface of the liquid9 The top of a mechanical shoe rim seal is less than 61 centimetres above the surface of the
liquid stored in the storage vessel
Storage vessels - OGI inspection 17 (1) On and after January 1 2018 a registered person shall ensure that each storage vessel
identified on the list required by subsection 9 (3) is inspected in accordance with this section (2) Subject to subsection (3) at least one time in every four-month period the registered person
shall ensure that each storage vessel mentioned in subsection (1) is inspected using an OGIinstrument to determine if VOCs are being discharged to the air from leaks in the storage vesselincluding from leaks in the floating roof
(3) Subsection (2) does not apply to a storage vessel that has been empty for the four-monthperiod
200Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 Floating roof - seal gap inspection
18 (1) On and after January 1 2018 the registered person shall ensure that the followingactions are performed in accordance with this section with respect to each storage vessel identified on the list required by subsection 9 (3) that is required to comply with paragraph 2 of subsection 10(1)
1 Inspect each rim seal to identify each gap between the rim seal and the two surfaces fromwhich the rim seal is intended to minimize air emissions in accordance with the procedure setout in subsection (3)
2 Inspect each deck fitting to identify each gap between a deck fitting gasket and the twosurfaces from which the gasket is intended to minimize air emissions in accordance with theprocedure set out in subsection (4)
3 Determine the ratio of accumulated area of rim seal gaps to storage vessel diameter inaccordance with the procedure set out in subsection (5)
(2) The actions required by subsection (1) shall be performed each time a storage vessel isempty
(3) Each location where a 032 centimetre diameter probe passes freely between the followingsurfaces shall be identified as a gap for the purpose of paragraph 1 of subsection (1)
1 The rim seal and the storage vessel wall2 The rim seal and the floating deck rim(4) Each location where a 032 centimetre diameter probe passes freely between the following
surfaces shall be identified as a gap for the purpose of paragraph 2 of subsection (1) 1 The gasket and the floating deck2 The gasket and the deck fitting(5) The ratio of accumulated area of rim seal gaps to storage vessel diameter mentioned in
paragraph 3 of subsection (1) shall be determined in accordance with the following procedure 1 Identify each gap in the rim seal by inserting a 032 centimetre diameter probe between the rim
seal and the storage vessel wall Each location where the probe passes freely between therim seal and the vessel wall constitutes a rim seal gap
2 Slide the probe along the storage vessel wall in each direction as far as it will travel freelywithout binding between the rim seal and the storage vessel wall The circumferential lengthalong which the probe can move freely is the rim seal gap length
3 Insert probes the diameters of which increase in increments of 032 centimetres between therim seal and the storage vessel wall The diameter of the largest probe that can be insertedfreely anywhere along the length of the gap is the maximum rim seal gap width
4 Determine the average width of each rim seal gap by averaging the minimum and maximumrim seal gap width
5 Calculate the area of a rim seal gap by multiplying the rim seal gap length determined underparagraph 2 by the average rim seal gap width determined under paragraph 4
6 Repeat steps 2 to 5 for each rim seal gap identified under paragraph 17 Calculate the ratio of accumulated area of rim seal gaps to storage vessel diameter by adding
the area of each rim seal gap determined under paragraphs 5 and 6 and dividing the sum bythe diameter of the storage vessel
Storage vessel repair 19 (1) A registered person shall ensure that each defect and gap is repaired in accordance with
this section if (a) an inspection required by subsection 16 (1) indicates a defect listed in subsection 16 (7)(b) an inspection required by subsection 17 (1) indicates that VOCs are being discharged to the
air from leaks in the storage vessel(c) an inspection required by paragraph 1 or 2 of subsection 18 (1) indicates one or more gaps or
201Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 (d) a re-inspection required by subsection (5) indicates that a repair required under this subsection
did not stop a leak(2) Each defect and gap required to be repaired by subsection (1) shall be repaired(a) prior to re-filling the storage vessel if the inspection is performed while the storage vessel is
not storing liquid or(b) subject to subsection (3) no later than 200 days after the date of the inspection if the
inspection is performed while the storage vessel is storing liquid(3) Clause (2) (b) does not apply if the storage vessel is completely emptied and de-gassed no
later than 200 days after the date of the inspection (4) The registered person shall ensure that each defect or gap is repaired prior to re-filling a
storage vessel described in subsection (3) (5) The registered person shall ensure that no later than 20 days following the repair required
under subsection (1) the storage vessel is re-inspected using an OGI instrument to determine whether the repair has stopped the leak
Requirement to notify ndash recurring repairs 20 (1) If a defect or gap in a floating roof of a storage vessel at a petroleum refining facility is
required to be repaired by subsection 19 (1) and two or more repairs have been required bysubsection 19 (1) in respect of the same storage vessel in the preceding 24-month period the registered person shall ensure that a provincial officer is notified in writing no later than five daysafter the inspection that identified the defect or gap
(2) No later than 30 days after notification is required to be given under subsection (1) theregistered person shall ensure that the following information is submitted in writing to a provincialofficer
1 A description of each gap or defect2 A description of the repair made3 An explanation of steps taken to prevent minimize or reduce the chance of the defect or gap
recurring in the future
Storage vessels in benzene service ndash general record 21 A registered person shall ensure that the following information is recorded for each storage
vessel identified on the list required by subsection 9 (3) 1 The design capacity in cubic metres of the storage vessel2 The absolute internal pressure in kilopascals at which the storage vessel is designed to
operate3 The date on which the storage vessel was last emptied4 The date on which the storage vessel is next anticipated to be emptied5 The type of roof on the storage vessel6 If benzene from the storage vessel is conveyed in a manner set out in section 4 a description
of how and to where the benzene is conveyed
Storage vessel inspection record 22 A registered person shall ensure that the following information is recorded for each inspection
required by subsections 16 (1) 17 (1) 18 (1) and 19 (5) 1 The identification number of the storage vessel for which the inspection was conducted2 The date of the inspection3 The type of inspection performed4 The position title of the personnel who assigned an individual to perform the inspection5 The results of the inspection including the following information
202Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 i If the inspection was an inspection required by subsection 16 (1) a summary of any
defects observed during the inspectionii If the inspection was an inspection required by subsection 17 (1) and it was determined
that VOCs were being discharged to the air a copy of the image produced by the OGIinstrument
iii If the inspection was an inspection required by subsection 18 (1) all gaps identified inaccordance with subsections 18 (3) and (4) and the ratio of accumulated area of rim sealgaps to storage vessel diameter calculated in accordance with paragraph 7 of subsection18 (5)
6 A description of any repairs required by section 19 including the date that the repair wasmade
7 A copy of the image produced by the OGI instrument in the re-inspection required bysubsection 19 (5)
Rim seal gap report ndash storage vessels 23 (1) No later than 30 days after an inspection required by subsection 18 (1) indicates that one
or more of the following criteria are met the registered person shall ensure that a report is prepared in accordance with subsection (2)
1 The ratio of accumulated area of rim seal gaps to storage vessel diameter exceeds 212 squarecentimetres per metre with respect to a primary rim seal
2 The ratio of accumulated area of rim seal gaps to storage vessel diameter exceeds 212square centimetres per metre with respect to a secondary rim seal
(2) The report mentioned in subsection (1) shall include the following information1 The date of the inspection that identified the rim seal gaps used to calculate the ratio
mentioned in subsection (1)2 The date of the previous inspection required by subsection 18 (1)3 A description of the results of the inspection that identified the rim seal gaps mentioned in
paragraph 1 including the area of each rim seal gap identified in the inspection4 A description of a plan of repair including the anticipated date of the repair required by clause
19 (1) (c)5 A written record indicating that the highest-ranking individual at the petroleum refining facility
has reviewed that the report has been prepared in accordance with this industry standardPART IV ndash AIR EMISSIONS FROM INDUSTRIAL SEWAGEApplication sections 24 and 25
231 (1) Sections 24 and 25 do not apply to a device if it is used as a primary oil-water separatorfor no more than 240 hours in the preceding 12-month period
Primary oil-water separators ndash requirement selection 24 (1) A registered person shall elect in writing to the Director with respect to each primary oil-
water separator at the petroleum refining facility whether the primary oil-water separator will meetthe requirements set out in paragraph 1 2 or 3 of subsection 25 (1)
(11) The election mentioned in subsection (1) shall be made or amended by the later of thefollowing dates
1 March 1 20182 The date the primary oil-water separator is first used at the facility(2) If a registered person does not make or amend an election in accordance with subsection
(11) with respect to a primary oil-water separator the registered person is deemed to have electedthat the primary oil-water separator will meet the requirements set out in paragraph 3 of subsection 25 (1)
(3) If a registered person elects under subsection (1) that a primary oil-water separator will meetthe requirements set out in paragraphs 1 or 2 of subsection 25 (1) the registered person may
203Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 change the election in writing to the Director to elect that the primary oil-water separator will meetthe requirements set out in paragraph 3 of subsection 25 (1)
(4) Unless a registered person is required to comply with subsection (5) the registered personshall ensure that each primary oil-water separator at a petroleum refining facility meets the requirements set out in the paragraph of subsection 25 (1) that the registered person elected underthis section
(5) No later than 24 months after a primary oil-water separator meets one or more of the followingcriteria a registered person shall ensure that the primary oil-water separator meets the requirements set out in paragraph 3 of subsection 25 (1)
1 The annual average concentration of benzene measured by a monitor required by paragraph 1of subsection 25 (1) in respect of the primary oil-water separator determined in accordancewith subsection 25 (21) is greater than 50 micrograms per cubic metre
2 The annual average emission rate of benzene from the primary oil-water separatordetermined in accordance with paragraph 2 of subsection 25 (1) is greater than 20 milligramsper second
Primary oil-water separators ndash monitoring and control requirements 25 (1) A registered person shall ensure that each primary oil-water separator at a petroleum
refining facility meets at least one of the following requirements in accordance with section 24 1 On and after July 1 2018 the concentration of benzene in the air shall be measured in
accordance with subsection (2) by at least one ambient monitor that is located no more than200 metres and no less than 100 metres downwind of the primary oil-water separator and theannual average concentration of benzene measured by a monitor shall be determined inaccordance with subsection (21)
2 On and after July 1 2018 the parameters in Table 6-25 shall be measured or otherwisedetermined and the annual average emission rate of benzene from the primary oil-waterseparator shall be determined all in accordance with subsection (3)
3 Subject to subsection (6) on and after January 1 2019 the primary oil-water separator shallmeet at least one of the following criteria
i Each separation zone of the primary oil-water separator shall be equipped with an internalor external floating roof that meets the requirements set out in subsection (5)
ii Benzene which would otherwise be discharged to the air from each separation zone of theprimary oil-water separator shall be conveyed in a manner set out in section 4
(2) A monitor mentioned in paragraph 1 of subsection (1) shall be located and operated inaccordance with a plan that in the opinion of the Director is adequate to result in the effective measurement of the concentration of benzene in the air in the vicinity of the primary oil-waterseparator
(21) The annual average concentration of benzene measured by a monitor mentioned in paragraph 1 of subsection (1) shall subject to subsection (22) be based on the measurementstaken during the period from January 1 to December 31 in a year and shall be determined before March 31 in the following year
(22) The first time the annual average concentration of benzene measured by a monitor isdetermined under paragraph 1 of subsection (1) the concentration shall be based on the first 12 months of measurements and shall be determined before the date that is three months after the end of the 12-month period
(3) The annual average emission rate of benzene mentioned in paragraph 2 of subsection (1)shall
(a) be determined in accordance with a plan that in the opinion of the Director meets therequirements set out in subsection (4) and is adequate to result in the effective determinationof the emission rate and
(b) subject to subsection (31) be based on the measurements taken during the period fromJanuary 1 to December 31 in a year and shall be determined before March 31 in the followingyear
204Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 (31) The first time the annual average emission rate of benzene is determined under paragraph 2
of subsection (1) the rate shall be based on the first 12 months of measurements and shall be determined before the date that is three months after the end of the 12-month period
(4) The plan mentioned in subsection (3) shall meet the following requirements1 The plan shall require that the annual average emission rate of benzene be calculated by
taking the average of benzene emission rates calculated for each week based on theparameters set out in Column 1 of Table 6-25
2 The plan shall require that each parameter set out in Column 1 of Table 6-25 is determined inaccordance with the rules set out opposite the parameter in Column 2 of the Table
3 Despite paragraph 2 the parameters set out in Column 1 of Table 6-25 may be determinedeach calendar month instead of each week if each annual average emission rate of benzenefrom the primary oil-water separator calculated with respect to the preceding two calendaryears is no more than 10 milligram per second
4 Despite paragraph 1 if the parameters set out in Column 1 of Table 6-25 are determined eachcalendar month instead of each week the annual average emission rate of benzene shall becalculated by taking the average of benzene emission rates calculated for each month basedon the parameters set out in Column 1 of Table 6-25
TABLE 6-25 Parameters and determination rules Item Column 1
Parameter Column 2 Determination Rules
1 The flow rate of sewage entering the primary oil-water separator
i Measure or otherwise determine thedaily average for each day on whichthe concentration of benzene in thesewage entering the primary oil-waterseparator is measured
2 The concentration of benzene in the sewage entering the primary oil-water separator
i Measure at least once per week
3 The flow rate of sewage leaving the primary oil-water separator
i Measure or otherwise determine thedaily average for each day on whichthe concentration of benzene in thesewage leaving the primary oil-waterseparator is measured or
ii Assume the value of the parameter tobe zero for the week
4 The concentration of benzene in the sewage leaving the primary oil-water separator
i Measure at least once per week orii Assume the value of the parameter to
be zero for the week5 The removal rate of skimmed oil waste
from the primary oil-water separator i Measure or otherwise determine for
each week the weekly average for theparameter
ii Assume the value of the parameter tobe zero for the week or
iii In circumstances in which skimmed oilwaste is accumulated over more thanone week determine an equivalentweekly average removal rate for eachweek in the accumulation period by
205Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1 Parameter
Column 2 Determination Rules
dividing the volume of accumulated oil waste removed from the primary oil-water separator by the number of weeks in the accumulation period
6 The concentration of benzene in the skimmed oil waste removed from the primary oil-water separator
i Measure at least once per weekii Assume the value of the parameter to
be zero for the week oriii If oil waste accumulates for more than
a week measure the concentration inthe accumulated oil waste removedfrom the primary oil-water separatorand use that concentration for eachweek in the accumulation period
7 The removal rate of waste sludge from the primary oil-water separator
i Measure or otherwise determine foreach week a weekly average for theparameter
ii Assume the value of the parameter tobe zero for the week or
iii In circumstances in which wastesludge is accumulated over more thanone week determine an equivalentweekly average removal rate for eachweek in the accumulation period bydividing the volume of accumulatedwaste sludge removed from theprimary oil-water separator by thenumber of weeks in the accumulationperiod
8 The mass fraction on a dry-weight basis of benzene in the waste sludge removed from the primary oil-water separator
i Measure at least once per weekii Assume the value of the parameter to
be zero for the week oriii If waste sludge accumulates for more
than a week measure the massfraction in the accumulated wastesludge removed from the primary oil-water separator and use that massfraction for each week in theaccumulation period
9 The concentration of Total Solids in the waste sludge removed from the primary oil-water separator
i Measure at the same time as themeasurement of the mass fraction ofbenzene in the waste sludge removedfrom the primary oil-water separator or
ii Assume the value of the parameter tobe zero for the week
206Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(5) A registered person shall ensure that each primary oil-water separator at a petroleum refiningfacility that is required to comply with subparagraph 3 i of subsection (1) complies with the followingrequirements
1 The floating roof shall have a secondary rim seal andi a liquid-mounted rim seal orii a mechanical shoe rim seal
2 Each deck fitting on the floating roof shall comply with the requirements set out in section 143 If the floating roof has a deck drain each deck drain shall be fitted with
i a slotted membrane fabric cover that covers at least 90 per cent of the deck drainii a flexible fabric sleeve seal oriii a gasketed deck cover
(6) If a separation zone has a device such as a skimmer that is required to operate at or abovethe liquid surface paragraph 3 of subsection (1) does not apply to the portion of the separation zone in which the device operates at or above the liquid surface if the surface area of the portion isnegligible relative to the surface area of the separation zone
(7) For the purposes of this sectionldquoaccumulation periodrdquo means the period of time since the last time that skimmed oil waste or waste sludge was removed from the primary oil-water separator
Primary oil-water separators floating roof ndash requirement to float 26 (1) A registered person shall ensure that for each primary oil-water separator that is required
to comply with subparagraph 3 i of subsection 25 (1) the floating roof floats on the surface of theliquid contained in the separation zone of the primary oil-water separator
(2) As soon as practicable after a contravention of subsection (1) the registered person shallensure that the primary oil-water separator is filled so that the roof floats on the surface of the liquidcontained in the separation zone of the primary oil-water separator
(3) The registered person shall ensure that a record of the following information is made withrespect to each contravention of subsection (1)
1 The identification number of the primary oil-water separator2 The date and time that the floating roof was identified as not floating3 The date and time that an action required by subsection (2) was taken
Primary oil-water separators floating roof ndash rim seal gap inspection 27 (1) For each primary oil-water separator at a petroleum refining facility that is required to
comply with subparagraph 3 i of subsection 25 (1) and which is equipped with an external floatingroof the registered person shall ensure that the following actions are performed in accordance withthis section
1 Inspect the primary rim seal to identify each gap between the rim seal and the primary oil-water separator wall in accordance with the procedure set out in subsection (4)
2 Determine the maximum rim seal gap width of each primary rim seal gap and determine theratio of accumulated area of primary rim seal gaps to perimeter of the floating roof inaccordance with the procedure set out in subsection (5)
3 Inspect the secondary rim seal to identify each gap between the rim seal and the primary oil-water separator wall in accordance with the procedure set out in subsection (4)
4 Determine maximum rim seal gap width of each secondary rim seal gap and determine theratio of accumulated area of secondary rim seal gaps to perimeter of the floating roof inaccordance with the procedure set out in subsection (5)
207Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 (2) The actions required by paragraphs 1 and 2 of subsection (1) shall be performed(a) no later than 60 days after the later of
(i) the date that sewage is first deposited in a primary oil-water separator at a petroleumrefining facility and
(ii) the date that the registered person is required to comply with subparagraph 3 i ofsubsection 25 (1) and
(b) no less than one time in every five-year period following the inspection required by clause (a)(3) The actions required by paragraphs 3 and 4 of subsection (1) shall be performed(a) no later than 60 days after the later of
(i) the date that sewage is first deposited in a primary oil-water separator at a petroleumrefining facility and
(ii) the date that the registered person is required to comply with subparagraph 3 i ofsubsection 25 (1) and
(b) no less than one time in every one-year period following the inspection required by clause (a)(4) Each location where a 032 centimetre diameter probe passes freely between a rim seal and
the primary oil-water separator wall shall be identified as a gap for the purpose of paragraphs 1 and3 of subsection (1)
(5) The ratio of accumulated area of rim seal gaps to perimeter of the floating roof mentioned inparagraphs 2 and 4 of subsection (1) shall be determined in accordance with the following procedure
1 Identify each gap in the rim seal by inserting a 032 centimetre diameter probe between the rimseal and the primary oil-water separator wall Each location where the probe passes freelybetween the rim seal and the primary oil-water separator wall constitutes a rim seal gap
2 Slide the probe along the primary oil-water separator wall in each direction as far as it willtravel freely without binding between the rim seal and the primary oil-water separator wall Thelength along which the probe can move freely is the rim seal gap length
3 Insert probes the diameters of which increase in increments of 032 centimetres between therim seal and the primary oil-water separator wall The diameter of the largest probe that can beinserted freely anywhere along the length of the gap is the maximum rim seal gap width
4 Determine the average width of each rim seal gap by averaging the minimum and maximumrim seal gap
5 Calculate the area of a rim seal gap by multiplying the rim seal gap length determined underparagraph 2 by the average rim seal gap width determined under paragraph 4
6 Repeat steps 2 to 5 for each rim seal gap identified under paragraph 17 Calculate the ratio of accumulated area of rim seal gaps to perimeter of the floating roof by
adding the area of each rim seal gap determined under paragraphs 5 and 6 and dividing thesum by the perimeter of the floating roof
Primary oil-water separator ndash OGI inspection 28 (1) A registered person shall ensure that each primary oil-water separator at a petroleum
refining facility that is required to comply with paragraph 3 of subsection 25 (1) is inspected using anOGI instrument at least one time in every four-month period to determine if VOCs are being discharged to the air from leaks in the primary oil-water separator
(2) If the primary oil-water separator mentioned in subsection (1) is required to comply withsubparagraph 3 i of subsection 25 (1) the inspection required by subsection (1) shall inspect thefloating roof to determine if VOCs are being discharged to the air from the floating roof
Primary oil-water separator repair 29 (1) A registered person shall ensure that each defect and gap is repaired in accordance withthis section if
(a) an inspection required by subsection 27 (1) indicates one or more rim seal gaps208Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 (b) an inspection required by subsection 28 (1) indicates that VOCs are being discharged to the
air from leaks in the primary oil-water separator or(c) a re-inspection required by subsection (3) indicates that a repair required under this subsection
did not stop a leak(2) Each defect and gap required to be repaired by subsection (1) shall be repaired no later than
200 days after the date of the inspection (3) The registered person shall ensure that no later than 20 days following the repair required
under subsection (1) the primary oil-water separator is re-inspected using an OGI instrument to confirm that the repair has stopped the leak
Primary oil-water separator record - general 30 (1) A registered person shall ensure that the following information is recorded for each primaryoil-water separator at the petroleum refining facility
1 Which requirement in subsection 25 (1) the primary oil-water separator is required to meet2 If the registered person has elected that the primary oil-water separator will meet the
requirement set out in paragraph 1 of subsection 25 (1)i Each measurement taken by each ambient monitorii The date and time of each measurement mentioned in subparagraph iiii The annual average of the concentration of benzene in the air measured by each ambient
monitor3 If the registered person has elected that the primary oil-water separator will meet the
requirements set out in paragraph 2 of subsection 25 (1) the annual average emission rate ofbenzene from the primary oil-water separator and all measurements and calculations requiredby subsection 25 (3)
4 If the registered person has elected that the primary oil-water separator will meet therequirement set out in paragraph 3 of subsection 25 (1) a description of the method set out inparagraph 3 of subsection 25 (1) associated with the primary oil-water separator
(2) The records required by paragraphs 2 and 3 shall be made at the same time as when themeasurement is taken or the calculation is made
Primary oil-water separator inspection record 31 A registered person shall ensure that the following information is recorded for each inspection
required by subsections 27 (1) and 28 (1) 1 The primary oil-water separator for which the inspection was conducted2 The date of the inspection3 The type of inspection performed4 The position title of the personnel who assigned an individual to perform the inspection5 If the inspection was an inspection required by subsection 27 (1) the following information
i Whether any primary rim seal gaps with a maximum rim seal gap width greater than 38centimetres were identified
ii The ratio of accumulated area of primary rim seal gaps to perimeter of the floating roofiii Whether any secondary rim seal gaps with a maximum rim seal gap width greater than 13
centimetres were identifiediv The ratio of accumulated area of secondary rim seal gaps to perimeter of the floating roof
6 If the inspection was an inspection required by subsection 28 (1) and it was determined thatVOCs were being discharged to the air from the primary oil-water separator a copy of theimage produced by the OGI instrument
7 A description of any repairs required by section 29 including the date that the repair wasmade
209Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 8 A copy of the image produced by the OGI instrument in the re-inspection required by
subsection 29 (3)
Rim seal gap report ndash primary oil-water separator 32 (1) No later than 30 days after an inspection required by subsection 27 (1) indicates that one
or more of the following criteria are met the registered person shall ensure that a report is prepared in accordance with subsection (2)
1 The width of a rim seal gap in the primary rim seal of a primary oil-water separator equals orexceeds 38 centimetres
2 The ratio of accumulated area of primary rim seal gaps to perimeter of the floating roofexceeds 67 square centimetres per metre of primary oil-water separator wall
3 The width of a rim seal gap in the secondary rim seal of a primary oil-water separator exceeds13 centimetres
4 The ratio of accumulated area of secondary rim seal gaps to perimeter of the floating roofexceeds 67 square centimetres per metre of primary oil-water separator wall
(2) The report mentioned in subsection (1) shall include the following information1 The date of the inspection that identified the rim seal gaps used to calculate the ratio
mentioned in subsection (1)2 The date of the previous inspection required by subsection 27 (1) of the primary oil-water
separator3 A description of the results of the inspection that identified the rim seal gaps mentioned in
paragraph 1 including the area of each rim seal gap identified in the inspection4 A description of a plan of repair including the anticipated date of the repair required by section
295 A written record indicating that the highest-ranking individual at the petroleum refining facility
has reviewed that the report has been prepared in accordance with this industry standard
Drains and maintenance access points ndash measurement and control requirements 33 (1) Subject to subsection (6) no later than July 1 2019 a registered person shall take one of
the actions set out in subsection (4) for each of the following things at the petroleum refining facility 1 Each drain that meets the criteria set out in subsection (2)2 Each maintenance access point that meets the criteria set out in subsection (3)(2) A drain meets the criteria mentioned in paragraph 1 of subsection (1) if the drain is not used
solely for storm water effluent and (a) is 200 metres or less from the property boundary of the facility or(b) is a drain that is directly connected by sewer line to a maintenance access point that is 200
metres or less from the property boundary of the facility(3) A maintenance access point meets the criteria mentioned in paragraph 2 of subsection (1) if
the maintenance access point is 200 metres or less from the property boundary of the facility (4) The registered person shall take at least one of the following actions in accordance with the
requirement set out in subsection (1) 1 Implement a plan that in the opinion of the Director will minimize benzene emissions from the
drain or maintenance access point2 Take one of the following actions for each drain and maintenance access point mentioned in
subsection (1) in accordance with a plan that in the opinion of the Director would effectivelydetermine the concentration or highest potential concentration of benzene in the sewage inthe drain or maintenance access point
i Measure the concentration of benzene in the sewage in the drain or maintenance accesspoint
210Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 ii Determine the highest potential concentration of benzene in the sewage in the drain or
maintenance access point by measuring the concentration of benzene in the sewage in anupstream drain or maintenance access point
(5) No later than 18 months after a measurement mentioned in paragraph 2 of subsection (4)indicates that the annual average concentration of benzene in sewage is greater than 100 milligrams per litre the registered person shall implement a plan mentioned in paragraph 1 ofsubsection (4)
(6) Subsection (1) does not apply with respect to a drain or maintenance access point if theDirector is satisfied that the sewage in the drain or maintenance access point does not contain benzene
(7) If a change may occur at the petroleum refining facility that may affect the concentration ofbenzene in the sewage in a drain or maintenance access point mentioned in subsection (6) the registered person shall notify the Director and provide the following information at least three months before the change is made
1 A description of the planned change2 A description of how the planned change may affect the benzene concentration in the sewage
in the drain or maintenance access point
Drain and maintenance access point record 34 A registered person shall ensure that the following information is recorded1 A map or schematic of the petroleum refining facility showing the location of each drain and
maintenance access point mentioned in subsection 33 (1)2 For each drain and maintenance access point at the petroleum refining facility mentioned in
subsection 33 (1)i a description of how benzene emissions are minimized in accordance with paragraph 1 of
subsection 33 (4) orii the results of the measurements or determinations required by paragraph 2 of subsection
33 (4)
PART V ndash PRODUCT LOADINGBenzene-containing product loading operations ndash application
35 (1) Subject to subsection (6) no later than March 31 2018 and March 31 in each followingyear the registered person shall ensure that the throughput of benzene-containing product for eachloading rack and loading berth at a petroleum refining facility during the preceding calendar year inlitres per year is determined and recorded
(2) Subject to subsection (4) the registered person shall ensure that benzene which wouldotherwise be discharged to the air from a cargo tank in a loading rack is conveyed in a manner setout in section 4 if the loading rack has a throughput of 14 million litres of benzene-containing productper year or greater
(3) Subject to subsection (4) the registered person shall ensure that benzene which wouldotherwise be discharged to the air from a cargo tank in a loading berth is conveyed in a manner setout in section 4 if the loading berth is located at a petroleum refining facility where the average totalthroughput of benzene-containing product for all loading berths at the petroleum refining facility is16 billion litres per year or greater in a three-year period
(4) Subsections (2) and (3) do not apply until the date that is 18 months after the throughputcriteria has been met
(5) For greater certainty the requirements set out in subsections (2) and (3) do not cease to applyif in a subsequent year the loading rack or loading berth does not meet the throughput criteria setout in those subsections
(6) Subsection (1) does not apply with respect to(a) a loading rack that meets or has previously met the throughput criteria set out in subsection
(2) or
211Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 (b) a loading berth that meets or has previously met the throughput criteria set out in subsection
(3)
Cargo tank loading operations ndash general operating requirements 36 A registered person shall ensure that the tank filling line used to load benzene-containing
product into a cargo tank is placed no higher than 10 centimetres above the bottom of the cargotank
Vapour-tight cargo tanks 37 On or after July 1 2018 a registered person shall ensure that vapour-tight cargo tanks are
used when benzene-containing product is loaded into a cargo tank at the petroleum refining facility
PART VI ndash LEAK DETECTION AND REPAIRComponent identification
38 (1) Subject to subsection (2) a registered person shall ensure that a written record is madeof each of the following components at the petroleum refining facility if the component is in benzene service
1 A compressor2 A pump3 A valve4 A pressure relief device5 A sample point6 An instrumentation system7 An agitator8 A connector(2) Subsection (1) does not apply to a component that(a) is operated at a pressure below atmospheric pressure(b) is a pump that is equipped with
(i) a dual mechanical seal(ii) a barrier fluid that is at a higher pressure than the operating pump pressure and(iii) a system that alerts the operator when the seal or barrier fluid has failed or
(c) is a valve or connector with a nominal diameter of less than 1875 centimetres or frac34 of an inch(3) Subject to subsection (4) a registered person shall ensure that each component required to
be recorded under subsection (1) is listed in a single electronic record with associated fields setting out the following information
1 The name and model number of the component2 The name of the manufacturer of the component3 The serial number of the component4 The purpose of the component5 The process unit of which the component is part6 Whether the component is in heavy liquid service7 Whether the component is an inaccessible component8 If in the opinion of the highest ranking individual at the petroleum refining facility the
component is an unsafe component the basis for the opinion that the component is unsafe9 The estimated percentage of benzene by weight to which the component is exposed
10 The date the component was installed212Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 11 If the component replaced a component the period of time the replaced component was in
service(4) Paragraphs 1 2 3 10 and 11 of subsection (3) do not apply with respect to a component that
was installed prior to January 1 2018 unless the component is a pump or a compressor (5) No later than 30 days after a change is made at the petroleum refining facility that would affect
the information in the record required by subsection (3) the registered person shall ensure that the record is updated to reflect the change
Component leak survey ndash general 39 (1) If the date is on or after January 1 2018 a registered person shall ensure that a
component leak survey is performed at the petroleum refining facility in accordance with this section (2) A component leak survey shall be completed(a) at least three times each calendar year with at least one component leak survey being
completed during each of the following periods(i) the period starting April 1 and ending June 30(ii) the period starting July 1 and ending September 30 and(iii) the period starting October 1 and ending December 31 or
(b) at least one time each calendar year if(i) the combined annual percentage of leaking valves in the previous calendar year
calculated in accordance with subsection 47 (1) is less than 10 per cent and(ii) the annual average concentration of VOCs from leaking components in the previous
calendar year calculated in accordance with subsection 47 (2) is less than 10000 ppm(3) A component leak survey required by clause (2) (b) shall be completed no later than 90 days
after the first component in the survey was assessed for leaks (4) Subject to subsection (5) a component leak survey required by subsection (1) shall assess
each component required to be recorded under subsection 38 (1) to determine if the component isleaking
(5) A component does not need to be included in a component leak survey if(a) the component was in benzene service for less than 300 hours in the previous calendar year
and the registered person has recorded the hours that the component was in benzene servicein the previous calendar year in accordance with paragraph 4 of subsection 48 (1)
(b) the component is identified in paragraph 6 of subsection 38 (3) as being in heavy liquidservice
(c) the date is on or before December 31 2022 and the component is identified in paragraph 7 ofsubsection 38 (3) as inaccessible or
(d) the component is identified in paragraph 8 of subsection 38 (3) as an unsafe component(6) No later than March 1 each year the registered person mentioned in subsection (1) shall
ensure that the Director and a provincial officer are given a written summary of the dates on which component leak surveys are anticipated to occur during the calendar year and ensure that representatives of the Ministry are given an opportunity to witness the survey Component leak survey ndash assessment and measurement of leaks
40 (1) A registered person shall ensure that a component leak survey required by subsection 39(1) is performed in accordance with this section
(2) Subject to subsection (3) each component that is part of a component leak survey required bysubsection 39 (1) shall be assessed using one of the following methods
1 A portable gas detector shall be used to assess for a gaseous leak and to measure theconcentration of VOCs discharged to air from a leaking component
2 An OGI instrument shall be used to assess for a gaseous leak3 A fixed leak detection system shall be used to assess for a gaseous leak and to measure the
concentration of VOCs discharged to air from a leaking component
213Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 (3) Subject to subsection (4) at least one time in each 12-month period a method set out in
paragraph 1 or 3 of subsection (2) shall be used to assess and measure each component mentioned in subsection (2)
(4) Subsection (3) does not apply to a component that is identified in paragraph 7 of subsection38 (3) as inaccessible
(5) On and after January 1 2023 each component that is part of a component leak surveyrequired by subsection 39 (1) that may contain a liquid shall be assessed for a liquid leak using anaudio or visual method to measure the leak rate of liquid discharged from each leaking componentThe liquid leak rate shall be measured in number of drops per minute
(6) A registered person shall ensure that a person who is required to perform a component leaksurvey receives training on the leak assessment methods mentioned in subsections (2) and (5) by aperson with experience in the relevant method
(7) No later than seven days after a leak is identified using an OGI instrument mentioned inparagraph 2 of subsection (2) the concentration of VOCs discharged to air from a leaking component shall be
(a) measured using a portable gas detector or(b) determined using an accessory device to the OGI instrument(8) For the purpose of this industry standard a determination made under clause (7) (b) is
deemed to be a measurement of the concentration of VOCs discharged to air from a leaking component
(9) The leak rate mentioned in subsection (5) shall be measured in accordance with the followingrules
1 Observe the component for at least one minute and count the number of drops seen or heard2 Repeat the observation required by paragraph 1 three times in a period of no more than ten
minutes3 Calculate the average of the leak rates observed under paragraphs 1 and 2
Component leak survey plan 41 (1) A registered person shall ensure that a component leak survey plan that meets the
requirements in this section is prepared prior to the initial component leak survey required bysubsection 39 (1)
(2) A component leak survey plan shall be in electronic form and shall include the followinginformation
1 A general description of the planned component leak survey including a description ofi the components that are to be part of the component leak surveyii the location of each component that will be part of the component leak surveyiii the method that will be used to assess each component for leaks in accordance with
subsections 40 (2) and (5)iv the percent by weight of benzene anticipated in leaks based on the percentage of
benzene by weight to which components in a process unit are exposed andv the training and experience of the individuals performing the component leak survey
2 If an OGI instrument will be used to perform the component leak survey the number of viewangles from which images will be taken for each component
3 A checklist of things to check or tasks to perform at the start of each day on which acomponent leak survey is performed including
i if a portable gas detector will be used to perform the component leak survey determiningand recording the calibration precision and the response time of the portable gas detectorin accordance with Appendix 6-D
ii if an OGI instrument will be used to perform the component leak survey confirmation thatthe date and time settings of the OGI instrument are correct and
214Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 iii if a fixed leak detection system will be used to perform any part of the component leak
survey an automated check for any malfunctioning sensors(3) No later than March 1 each year the registered person shall update the component leak
survey plan required by subsection (1) so that the information required in the plan is accurate for the surveys to be performed in the calendar year
(4) If the information required in the component leak survey plan required by subsection (1)changes after March 1 of a year the registered person shall ensure that the plan is updated so thatit is accurate
(5) If a change mentioned in subsection (4) affects the dates on which component leak surveysare anticipated to occur during the calendar year as set out under subsection 39 (6) the registered person shall ensure that the Director and a provincial officer are notified as soon as practicable ofthe change in dates
Additional leak measurements - pumps compressors and pressure relief devices 42 (1) Subject to subsection (2) a registered person shall ensure that a component required to
be recorded under subsection 38 (1) is observed visually and audibly to identify gaseous and liquid leaks at least one time in every 12-hour period if
(a) the date is on or after January 1 2023 and(b) the component is a pump compressor or pressure relief device(2) Subsection (1) does not apply with respect to a component if the component was in benzene
service for less than 300 hours in the previous calendar year and the registered person has made a record of the hours that the component was in benzene service in the previous calendar yearincluding the dates and times that the component was in benzene service in the previous calendar year
(3) The registered person shall ensure that the liquid leak rate from a leaking component ismeasured in accordance with the rules set out in subsection 40 (9) as soon as practicable after a liquid leak is identified under subsection (1)
(4) No later than seven days after a gaseous leak is identified under subsection (1) the registeredperson shall ensure that the concentration of VOCs discharged to air from a leaking component ismeasured using
(a) a portable gas detector or(b) a fixed leak detection system
Leaks - deviations and repair 43 (1) If the date is on or after January 1 2018 and before January 1 2020 and the
concentration of VOCs discharged to air from a leaking component is greater than or equal to 1000ppm by volume a registered person shall ensure that reasonable efforts are made to repair thecomponent within a reasonable timeframe so that the concentration of VOCs discharged to air fromthe component is less than 1000 ppm by volume
(2) A registered person shall ensure that repairs are made in accordance with subsection (3) ifone or more of the following criteria are met
1 A measurement required by this industry standard on or after January 1 2020 indicates thatthe concentration of VOCs discharged to air from a leaking component is greater than or equalto 1000 ppm by volume
2 A measurement required by this industry standard indicates that a component has a liquid leakrate of three drops per minute or greater
(3) Subject to subsection (4) and section 44 the repairs required by subsection (2) include(a) no later than five days after taking a measurement mentioned in subsection (2) making all
repairs to prevent minimize or reduce the leak that can feasibly be made in the five-day periodsuch as(i) if the component is a pump tightening the packing gland nuts and ensuring that the seal
flush is operating at design pressure and temperature and
215Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 (ii) if the component is a valve tightening the bonnet bolts replacing the bonnet bolts
tightening the packing gland nuts and injecting a lubricant into lubricated packing(b) if the date is on or after January 1 2020 and before January 1 2023 and the measurement is
in the range set out in Column 1 of Table 6-43 repairing the component within the repairperiod set out opposite the range in Column 2 of Table 6-43 so that the concentration of VOCsdischarged to air from the component is less than the concentration set out opposite the repairperiod in Column 3 of Table 6-43 and
(c) if the date is on or after January 1 2023 and the measurement is in the range set out inColumn 1 of Table 6-43 repairing the component within the repair period set out opposite therange in Column 4 of Table 6-43 so that the liquid leak rate or concentration of VOCsdischarged to air from the component is less than the leak rate or concentration set outopposite the repair period in Column 5 of Table 6-43
(4) A component does not need to be repaired within the applicable repair period set out in clause(3) (b) or (c) if the component is taken out of service no later than the last day in the repair periodset out in Column 2 or 4 of Table 6-43 as applicable
(5) A registered person shall ensure that a component mentioned in subsection (4) is repaired sothat concentration of VOCs discharged to air from the component is less than 1000 ppm by volumebefore the component is put back into service
TABLE 6-43 Leak Repair Item Column 1
Measuremen t Range
Column 2 Repair Period (2020-2022)
Column 3 Repair Range(2020-2022)
Column 4 Repair Period (2023 and later)
Column 5 Repair Range(2023 and later)
1 1000 ppm ndash less than 10 000 ppm of VOCs by volume
The 60-day period commencing the date the leak is measured
Less than 1000 ppm of VOCs by volume
The 30-day period commencing the date the leak is measured
Less than 1000 ppm of VOCs by volume
2 10000 ppm ndash 25000ppm of VOCs by volume
The 30-day period commencing the date the leak is measured
Less than 10000 ppm of VOCs by volume
The 15-day period commencing the date the leak is measured
Less than 10000 ppm of VOCs by volume
3 Greater than 25000 ppm of VOCs by volume
The 15-day period commencing the date the leak is measured
Less than 25000 ppm of VOCs by volume
The 7-day period commencing the time the leak is measured
Less than 25000 ppm of VOCs by volume
4 Greater than three drops per minute
NA NA The 7-day period commencing the date the leak is measured
0 drops per minute
Delay of repair list 44 (1) A component does not need to be repaired in accordance with the applicable repair
period set out in section 43 if the sum determined under subsection (3) is less than 250000 ppm byvolume and one or more of the following criteria are met
1 The process unit in which the component is located must be shut down in order to repair thecomponent
2 The component is a valve and the only repair that could be made to the valve withoutshutting down the process unit in which the valve is located is a drill and tap leak repair
216Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 (2) The registered person shall ensure that the following information is recorded with respect to
each component at a petroleum refining facility that is not repaired in accordance with the applicable repair period set out in section 43
1 The name of the component the component identifier and if the component was installedafter January 1 2018 the serial number of the component
2 The process unit of which the component is part3 The estimated fraction of benzene by volume that the component is exposed to4 The reason that the component could not be repaired within the applicable repair period set
out in section 435 The concentration of VOCs leaking from the component as measured under section 40 or 426 The calculated concentration of benzene leaking from the component calculated as the
product of the values set out in paragraphs 3 and 57 A description of any repairs made to the leaking component8 The date and time of the next anticipated shut-down of the process unit of which the
component is part(3) A registered person shall ensure the concentration of benzene recorded under paragraph 6 of
subsection (2) is summed for each component recorded for the purpose of subsection (2) that isexposed to 50 per cent or greater benzene by weight
(4) At least one time in each six-month period a registered person shall ensure that a report thatcontains the following information is signed by the highest-ranking individual at the petroleumrefining facility and submitted to a provincial officer
1 Each component set out in the record required by subsection (2)2 The length of time each component mention in paragraph 1 has been set out in the record
required by subsection (2)3 For each component mention in paragraph 1 the concentration of benzene leaking from the
component calculated in accordance with paragraph 6 of subsection (2)4 The sum determined under subsection (3)5 Each component that was set out in the previous report that is not set out in the report6 For each component mentioned in paragraph 5 the results of the measurement required by
section 45 following the repair to the component7 A comparison of the number of components set out in the report to the number of components
set out in the previous report8 A comparison of the sum mentioned in paragraph 4 to the sum set out in the previous report(5) A registered person shall ensure that the next time a process unit is shut down each
component set out in the record required by subsection (2) that is part of the process unit is repaired so that the concentration of VOCs discharged to air from each component is less than 1000 ppm byvolume
(6) Subject to subsection (7) if a component set out in the record required by subsection (2) is avalve a registered person shall ensure that the next time the process unit in which the valve islocated is shut down the valve is replaced with a low emission valve or repacked with low emission valve packing that meets the criteria set out in subsection 46 (2)
(7) Subsection (6) does not apply with respect to a valve for which there is no low-emissionreplacement or low emission packing if the registered person notifies the Director in writing no laterthan 30 days after the date that the process unit in which the valve is located is shut down that there is no low-emission replacement or low emission packing for the valve
(8) The notification required by subsection (7) shall include the following information1 The date of the shut-down of the process unit in which the component is located2 A description of the component3 An explanation of why there is no low-emission replacement4 A description of how the component was repaired instead of replaced
217Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 (9) No later than six months after a component set out in the record required by subsection (2) is
repaired the registered person shall submit the following information in writing to a provincialofficer
1 The date of the shut-down of the process unit in which the component is located2 The date the component was repaired3 A description of how the component was repaired4 The concentration of VOCs leaking from the component after the repair was made(10) In this section
ldquodrill and tap leak repairrdquo means a method of repairing a leaking valve by drilling a hole into the valvepacking gland tapping the gland so that a small valve and fitting can be attached to the gland andpumping new packing material into the gland
Re-measurement following component repair or replacement 45 (1) After a component is required to be repaired in accordance with section 43 or 44 or
replaced in accordance with section 46 a registered person shall ensure that the following measurements are made no later than the dates set out in subsection (2)
1 One of the following methods is used to measure the concentration of VOCs discharged to airfrom the component that was required to be repaired or replacedi a portable gas detector oriia fixed leak detection system
2 The liquid leak rate from the component required to be repaired or replaced is measured inaccordance with the rules set out in subsection 40 (9)
(2) The measurements required by subsection (1) shall be made(a) if the component is required to be repaired in accordance with subsection 43 (3) no later than
the last day in the repair period set out in Column 2 or 4 of Table 6-43 as applicable(b) if the component is required to be repaired in accordance with subsection 43 (5) no later than
seven days after the component is put back into service(c) if the component is required to be repaired in accordance with subsection 44 (5) no later than
30 days after the date that the process unit in which the component is located is placed backinto service and
(d) if the component is required to be replaced in accordance with section 46 no later than sevendays after the component is replaced
Component replacement 46 (1) A registered person shall ensure that a component required to be recorded under
subsection 38 (1) is replaced with a new component if the component has been repaired two timesin a 24-month period so that concentration of VOCs discharged to air from the component is lessthan 1000 ppm by volume and is required by this industry standard to be repaired a third time in theperiod
(2) Subject to subsection (3) if the component mentioned in subsection (1) is a valve the valveshall be replaced with a low emission valve or repacked with low emission valve packing that meetsthe following criteria
1 The valve or valve packing has been tested by the manufacturer to determine theconcentration of VOCs discharged from the valve or valve packing
2 The maximum concentration of VOCs determined under paragraph 1 shall not be greater than500 ppm by volume
3 The average concentration determined under paragraph 1 shall not be greater than 100 ppmby volume
(3) Subsection (2) does not apply with respect to a valve for which there is no low-emissionreplacement or low emission packing if the registered person notifies the Director in writing no later
218Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 than 30 days after the date that the process unit in which the valve is located is shut down that there is no low-emission replacement or low emission packing for the valve
(4) The notification required by subsection (3) shall include the following information1 The date of the shut-down of the process unit in which the component is located2 A description of the component3 An explanation of why there is no low-emission replacement4 A description of how the component was repaired instead of replaced(5) Subject to subsection (6) a registered person shall ensure that a component required to be
replaced under subsection (1) is replaced with a new component no later than the last day in the repair period associated with the third repair mentioned in subsection (1) set out in Column 2 or 4 ofthe Table 6-43 as applicable
(6) Subsection (5) does not apply to the replacement of a component if the component is takenout of service no later than the last day in the applicable replacement period set out in subsection(5)
(7) A registered person shall ensure that a component mentioned in subsection (6) is replacedbefore the component is put back into service Leaking components - annual calculations
47 (1) The combined annual percentage of leaking valves shall be calculated in accordance withthe following formula
where AT = the total number of valves that required repair under sections 43 and 44 following each
component leak survey required by subsection 39 (1) during a calendar year BT = the total number of valves assessed in each component leak survey required by subsection
39 (1) during a calendar year (2) The annual average concentration of VOCs from leaking components shall be calculated in
accordance with the following formula
where
XT = the sum of the concentration in ppm by volume of VOCs discharged to air from each component following each component leak survey required by subsection 39 (1) during acalendar year
YT = the total number of component for which a concentration was determined for XT
(3) The percentage of leaking components shall be calculated in accordance with the followingformula
where
RT = the total number of components that require repair under sections 43 and 44 CT = the total number of components assessed in the component leak survey required by
subsection 39 (1)
Records - component leak survey 48 (1) A registered person shall ensure that for each component required to be listed in the
electronic record required in subsection 38 (3) the following information is recorded in the electronicrecord with respect to each component leak survey required by subsection 39 (1)
219Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 1 The date the component was assessed for leaks2 The position title of the personnel who assigned an individual to assess the component for
leaks and the date the individual received the training required by subsection 40 (6)3 The method used to assess the component for leaks in accordance with section 40 including
i if a portable gas detector or OGI instrument is used to assess the component the uniqueidentifier of the detector or instrument used
ii if a fixed leak detection system is used to assess the component the distance from thecomponent assessed by the fixed leak detection system to each sensor that assessed thecomponent for leaks
4 If the component is not included in a component leak survey because the component was inbenzene service for less than 300 hours in the previous calendar year a notation that clause39 (5) (a) applies and the dates and times during which the component was in benzeneservice in the previous calendar year
5 If the component is not included in a component leak survey because it was identified insubsection 38 (3) as inaccessible or unsafe a notation that the component is identified asinaccessible or unsafe
6 The result of the assessment required by section 40 including if a leak is identifiedi if the assessment indicated that VOCs were being discharged to air in a concentration of
1000 ppm by volume or greater the measured concentration of VOCsii if an OGI instrument was used to assess the component and the follow-up measurement
required by subsection 40 (7) indicated that VOCs were being discharged to air in aconcentration of 1000 ppm by volume or greater
A the method used to perform the follow-up measurement required by subsection 40(7)
B a copy of the image or images produced by the OGI instrumentC the time that an image mentioned in sub-subparagraph B was takenD the wind speed that is published by Environment and Climate Change Canada for the
area in the vicinity of the facility on the date that the component was assessed forleaks
E an indication of whether it was sunny or overcast at the time that the component wasassessed for leaks and
iii if the assessment indicated that the component had a liquid leak rate of three drops perminute or greater the measured liquid leak rate
7 If a concentration indicated in accordance with subparagraphs 6 i or ii is 1000 ppm by volumeor greater the estimated mass emission rate of benzene in grams per second and adescription of how the mass emission rate was estimated
8 A description of each action taken to repair the leak including the date each action was taken9 The position title of the personnel who assigned an individual to make the repair
10 The likely cause of the leak11 The date that measurements required by subsection 45 (1) were made12 The method used to make to take the measurements required by subsection 45 (1)13 The result of the measurements required by subsection 45 (1) including the concentration of
VOCs or liquid leak rate measured as applicable(2) After the completion of each component leak survey performed at a petroleum refining facility aregistered person shall ensure that a record of the following information is made
1 The start date and end date of the component leak survey2 A summary of the methods used in the component leak survey3 The percentage of leaking components calculated in accordance with subsection 47 (3)
220Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 4 An indication of whether the operating conditions at the petroleum refining facility were normal
on each day of the component leak survey5 If a fixed leak detection system was used for any part of the component leak survey for each
fixed leak detection system usedi the number of sensors used to assess components for leaksii the manufacturer and model number of each sensoriii the type of each analyzer linked to each sensoriv the manufacturer and model number of each analyzerv the year each sensor was installedvi the year each analyzer was installed andvii a record of any sensors that malfunctioned during the automated checks required by
subparagraph 3 iii of subsection 41 (2)6 If a portable gas detector was used for any part of the component leak survey
i the manufacturer and model number of each portable gas detector andii for each day on which part of a component leak survey was performed using a portable
gas detectorA the unique identifier of each portable gas detector used on the dayB the concentration of calibration gas used to determine the calibration precision and
the response time of each portable gas detector used on the dayC the calibration precision and response time of each portable gas detector used on the
day determined in accordance with Appendix 6-D andD if a portable gas detector used on the day uses flame ionization to detect VOCs and
a calibration gas other than methane was used to determine the calibration precisionand response time of the portable gas detector the response factor used to adjustthe portable gas detector in accordance with subsection 1 (3) of Appendix 6-D
7 If an OGI instrument was used for any part of the component leak survey the manufacturermodel number and unique identifier of each OGI instrument
Records ndash additional leak measurements 49 If a measurement required by section 42 identifies that the concentration of VOCs discharged
to air from a leaking component is greater than or equal to 1000 ppm by volume or that a component has a liquid leak rate of three drops per minute or greater the registered person shallensure that the following information is recorded with respect to the leaking component in the electronic record required in subsection 38 (3)
1 The date and time that the component was identified as leaking2 The name of the individual who identified the component as leaking3 The concentration of VOCs discharged to air from the component or liquid leak rate measured
as required by subsection 42 (3) or (4)4 The date and time that the liquid leak rate or concentration of VOCs discharged to air from the
component was measured5 The name of the individual who measured the liquid leak rate or concentration of VOCs
discharged to air from the component6 The method used to measure the liquid leak rate or concentration of VOCs discharged to air
from the component7 If the concentration mentioned in paragraph 3 was measured using a portable gas detector
i the unique identifier of the portable gas detectorii the concentration of calibration gas used to determine the calibration precision and
response time of the portable gas detector
221Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 iii the calibration precision and response time of the portable gas detector determined in
accordance with Appendix 6-D andiv if the portable gas detector uses flame ionization to detect VOCs and a calibration gas
other than methane was used to determine the calibration precision and response time ofthe portable gas detector the response factor used to adjust the portable gas detector inaccordance with subsection 1 (3) of Appendix 6-D
8 If the leak is a gaseous leak the estimated mass emission rate of benzene in grams persecond and a description of how the mass emission rate was estimated
9 A description of each action taken to repair the leak including the date each action was taken10 The position title of the personnel who assigned an individual to make the repair11 The likely cause of the leak12 The date that measurements required by subsection 45 (1) were made13 The result of the measurements required by subsection 45 (1) including the concentration of
VOCs or liquid leak rate measured as applicable
PART VII ndash OPERATIONTechnology requirements ndash open-ended valves 50 A registered person shall ensure that each open-ended valve at the petroleum refining facilitythat is in benzene service is equipped with a cap blind flange plug or a second valve that seals theopen end
Technology requirements ndash surge control vessels and bottoms receivers 51 (1) A registered person shall ensure that on and after January 1 2020 benzene from each ofthe following things at the petroleum refining facility is conveyed in a manner set out in section 4
1 A surge control vessel that is in benzene service2 A bottoms receiver that is in benzene service(2) On and after January 1 2020 for each surge control vessel and bottoms receiver mentioned
in subsection (1) a registered person shall ensure that a written description is made that sets outhow and to where the benzene is conveyed
Operating parameter summary table 52 (1) Subject to subsections (2) (3) and (5) on and after January 1 2018 a registered person
shall ensure that a table labelled ldquoOperating Parameter Summary Tablerdquo is prepared thatreproduces Table 6-52 in a manner that includes each method listed in Column 1 of Table 6-52 thatis at the petroleum refining facility and that is associated with a registered contaminant
(2) A registered person who is required under subsection (1) to reproduce Item 4 of Table 6-52 inthe Operating Parameter Summary Table does not have to set out the information in Columns 3 to 6 of Item 4 of Table 6-52 if the person sets out the information in the following manner
1 Column 3 Concentration of VOCs (ppm)2 Column 4 Outlet3 Column 5 One time in each 24-month period4 Column 6 -shy(3) Where Table 6-52 refers to an operating parameter location or frequency that is to be
consistent with a recommendation made by a professional the recommendation and the source ofthe recommendation shall be set out in the Operating Parameter Summary Table
(4) The source of the professional recommendation mentioned in subsection (3) shall be one ofthe following
1 An operating and maintenance manual provided by a manufacturer of the thing for which therecommendation is being given
222Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 2 Written instructions provided by a supplier of the thing for which the recommendation is being
given3 A letter from a manufacturer mentioned in paragraph 1 or supplier mentioned in paragraph 2
setting out the recommendation4 A letter from a professional engineer setting out the recommendation the rationale for the
recommendation and a description of the relevant experience with respect to therecommendation being made The engineer must have relevant experience with respect tothe recommendation being made
(5) The Director may order a registered person to do one or more of the following1 Include information in Columns 3 to 6 of the Operating Parameter Summary Table if the
Director is of the opinion that the information is necessary to ensure the normal operation ofthe method
2 Remove information from Columns 3 to 6 of the Operating Parameter Summary Table if theDirector is of the opinion that the information is not appropriate to ensure the normal operationof the method
(6) No later than 30 days after a change is made at the petroleum refining facility that would affectthe information in the Operating Parameter Summary Table the Table shall be updated to reflectthe change
TABLE 6-52 Structure for Operating Parameter Summary Table
Item Column 1 Method
Column 2 Equipment Associated with the Method
Column 3 Operating Parameter
Column 4 Measurement Location
Column 5 Measurement Frequency
Column 6 Calculated Parameter
1 Flare Equipment Pilot Flame On or Off Pilot Flame
Continuously when a substance is being conveyed to the flare
-shy
2 Thermal Oxidizer Equipment Temperature
At the point that represents a residence time of 075 seconds
Continuously -shy
3 Catalytic Oxidizer Equipment Temperature
A location consistent with a professional recommendation
Continuously -shy
4
Air pollution control device required by paragraph 2 of subsection 4 (1) other than a thermal oxidizer or a catalytic oxidizer
Equipment Concentration of benzene
1 Inlet2 Outlet
One time in each 24-month period
Per cent removal of benzene = [1 ndash (CoutletCinlet)]
223Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1 Method
Column 2 Equipment Associated with the Method
Column 3 Operating Parameter
Column 4 Measurement Location
Column 5 Measurement Frequency
Column 6 Calculated Parameter
5
A method required by section 56
Equipment
One or more operating parameters consistent with a professional recommendation
A location consistent with a professional recommendation
A frequency consistent with a professional recommendation
-shy
Measurement of operating parameters 53 (1) A registered person shall ensure that each operating parameter set out in Column 3 of the
Operating Parameter Summary Table required by section 52 is measured at least as often as the frequency required to be set out in Column 5 of the Table at the location required to be set out in Column 4 of the Table
(2) The results of the measurements required by subsection (1) shall be used to determine thecalculated parameter in Column 6 of the Operating Parameter Summary Table required by section52
(3) The measurements required by subsection (1) for Item 4 of Table 6-52 shall be taken inaccordance with a plan that in the opinion of the Director is adequate to result in the effective measurement of the operating parameter mentioned in subsection (1)
(4) Each time a measurement is required to be taken by subsection (1) for Item 4 of Table 6-52the registered person shall ensure that
(a) written notice is provided to the Director at least 15 days before the measurement is taken(b) an opportunity is provided for representatives of the Ministry to witness the taking of the
measurement and(c) no later than four months after the measurements are taken the results of the measurements
are submitted to the Director and a provincial officer(5) Measurements required by subsection (1) with respect to Item 1 of Table 6-52 shall be taken
using one or more of the following technologies 1 A thermocouple2 An optical system that uses ultraviolet or infrared technology3 Flame ionization4 An acoustic system
(6) A registered person shall ensure that an instrument used to measure an operating parameter forthe purpose of this industry standard is calibrated in accordance with a recommendation made by aprofessional The source of the recommendation shall be one of the sources set out in subsection52 (4)(7) A registered person shall ensure that the following information is recorded
1 Each measurement required to be taken under subsection (1)2 Each calculation required to be made under subsection (2)3 The date on which the measurement in paragraph 1 was taken and the calculation in
paragraph 2 was made
Phase-in for new air pollution control devices 54 Sections 52 and 53 do not apply in respect of an air pollution control device at a petroleum
refining facility for a period of six months after the installation of the device if the device is installed
224Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 after the date on which the petroleum refining facility is first registered with respect to this industrystandard
PART VIII ndash REQUIREMENT TO CONTINUE THE USE OF METHODS TO MANAGE EMISSIONSIdentifying managed sources
55 (1) A registered person shall ensure that a table is prepared in accordance with this sectionand updated in accordance with section 57
(2) The table required by subsection (1) shall contain the following information1 Column 1 Each piece of equipment at the petroleum refining facility from which the discharge
of a registered contaminant is prevented minimized or reduced by a method mentioned insubsection (3)
2 Column 2 Opposite each piece of equipment required to be set out by paragraph 1 eachmethod mentioned in subsection (3) that prevents minimizes or reduces the discharge of aregistered contaminant from the piece of equipment
(3) A method mentioned in subsection (2) includes a method such as(a) the use of an air pollution control device(b) the selection and use of equipment that more effectively prevents minimizes or reduces the
discharge of a registered contaminant than the selection or use of other equipment(c) the operation of a process in a manner that prevents minimizes or reduces the discharge of a
registered contaminant into the air from one or more sources of contaminant(d) the design installation and operation of a stack in a manner that increases the dispersion of a
registered contaminant and(e) the use of material to prevent minimize or reduce the discharge of a registered contaminant to
the air for example material substitution(4) If a method mentioned in subsection (2) is the selection of equipment in accordance with
clause (3) (b) the equipment shall be listed as the method in Column 2 of the table required bysubsection (1) and as the equipment in Column 1 of the table
Requirement to continue the management of sources 56 A registered person shall not operate or cause or permit the operation of equipment set out in
the table required by section 55 unless the discharge of registered contaminants from the equipmentis prevented minimized or reduced by a method that is at least as effective at preventingminimizing or reducing the discharge into the air as the associated method required to be listed opposite the equipment in Column 2 of the table
Changes to managed sources 57 (1) No later than 30 days after any of the following changes occur at a petroleum refining
facility the table required by section 55 shall having regard to subsection (2) be updated inaccordance with the following rules
1 If a method to prevent minimize or reduce the discharge of a registered contaminant is addedor replaced at the petroleum refining facility the table shall be updated to reflect the change
2 If a piece of equipment that may discharge or from which may be discharged a registeredcontaminant is added or replaced at the petroleum refining facility the table shall be updatedto reflect the change
3 If a piece of equipment set out in the table is removed from the petroleum refining facility thepiece of equipment shall be removed from the table
4 If all equipment associated with a method set out in the table has been removed from thetable the method shall be removed from the table
5 If a notice given under subsection (4) indicates that a method is no longer necessary themethod shall be removed from the table
225Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 6 If the table is updated in accordance with paragraph 5 such that no method is set out opposite
a piece of equipment in the table the piece of equipment shall be removed from the table(2) Subject to subsections (3) and (4) a change mentioned in subsection (1) shall not be made
unless the following criteria are met 1 A change that adds replaces or otherwise alters a method shall add replace or alter the
method in a manner that is at least as effective at preventing minimizing or reducing thedischarge of registered contaminants as the method that was listed in the table immediatelyprior to the change
2 A change that adds a piece of equipment that is similar to a piece of equipment required to beset out in the table shall only be made if Column 2 of the table contains a method that is atleast as effective at preventing minimizing or reducing the discharge of registeredcontaminants as the most effective method associated with a similar piece of equipment
(3) Subsection (2) does not apply if the change is required by a section of this industry standardother than this section
(4) The Director may upon request give a registered person written notice indicating that achange that does not meet the requirements mentioned in subsection (2) may be made in accordance with the notice if the Director is of the opinion that at least one of the following statements is true
1 The method that is the subject of the request is comparable to the effectiveness of the methodthat would be required by subsection (2)
2 Any adverse effect would likely not be better prevented eliminated or ameliorated if a methodrequired by subsection (2) were used
3 No adverse effect is likely to occur4 The registered contaminants affected by the change are discharged in an amount that is
negligible(5) A request that is made in respect of subsection (4) shall be made by a registered person and
shall include the following information 1 A rationale for the request2 Each piece of equipment associated with the method that is the subject of the request(6) Before the Director gives a person a notice under subsection (4) the Director shall give the
person a draft of the notice and an opportunity to make written submissions to the Director during the period that ends 30 days after the draft is given
Specified source management 58 The Director may order a registered person to use a method if(a) a change was made to a method that in the opinion of the Director does not meet the criteria
set out in subsection 57 (2) or(b) a piece of equipment is or was previously listed in the table required by section 55 and the
Director is of the opinion that discharges from the equipment may cause an adverse effect
Notification of changes to management of sources 59 (1) Subject to subsection (2) no later than 30 days after a change mentioned in section 57 or
58 is made at a petroleum refining facility the registered person shall ensure that a provincial officeris notified in writing of the change
(2) Subsection (1) does not apply if the thing affected by the change is a thing which maydischarge or from which may be discharged a registered contaminant in an amount that is negligible
(3) The notification required by subsection (1) shall include the following information1 A description of the change including a description of the equipment and methods affected by
the change and the date that the change was made2 One of the following with respect to the change mentioned in paragraph 1
226Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 i An explanation of how the change meets the criteria set out in subsection 57 (2)ii If the change was authorized by a notice given under subsection 57 (4) the reference
number of the noticeiii If the change was required by an order given under section 58 the reference number of
the order
PART IX ndash AMBIENT MONITORINGAmbient monitoring - benzene
60 (1) On and after January 1 2018 a registered person shall ensure that the concentration ofbenzene discharged from the petroleum refining facility into the air is measured by
(a) at least 12 ambient monitors if the petroleum refining facility is on a property that is 80hectares or greater or
(b) at least six ambient monitors if the petroleum refining facility is on a property that is less than80 hectares
(2) Each monitor required by subsection (1) shall(a) sample the air continuously over a two-week period(b) be in the opinion of the Director adequate to effectively measure the concentration of
benzene in the air and(c) be in the opinion of the Director located in a manner that adequately reflects the benzene
discharged from the petroleum refining facility(3) In forming the opinion required under clause (2) (b) the Director shall have regard to(a) the type of monitor(b) the make and model of the monitor(c) the frequency of measurement of the monitor and(d) the sampling and analytical protocols to be used with the monitor(4) In forming the opinion required under clause (2) (c) the Director shall have regard to(a) the property boundary of the petroleum refining facility(b) the wind rose or predominant wind direction at the petroleum refining facility(c) the location and height of the sources of contaminant that discharge benzene to the air at the
petroleum refining facility including(i) storage vessels(ii) product loading areas and(iii) sewage treatment
(d) the presence of any of the following places near the petroleum refining facility(i) a health care facility(ii) a senior citizensrsquo residence or long-term care facility(iii) a child care facility(iv) an educational facility and(v) a dwelling
(e) whether a local First Nation may be interested in the location of the monitors and(f) the location of the other monitors required by subsection (1)(5) A registered person shall ensure that the air sampled over a two-week period by a monitor
required by subsection (1) is analysed in a laboratory as soon as reasonably possible to determine the concentration of benzene in micrograms per cubic metre
(6) A registered person shall ensure that the following information is recorded for each monitor
227Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 1 The location of the monitor2 Each measured concentration of benzene mentioned in subsection (5)3 For each value mentioned in paragraph 2 the dates of the period of time during which the
monitor sampled air
Benzene measurements baseline 61 (1) A registered person shall ensure that a baseline for benzene at a petroleum refining
facility is determined in accordance with this section (2) No later than March 31 in the year following the first full three calendar years in which this
section applies in respect of the petroleum refining facility mentioned in subsection (1) a baseline shall be determined by performing the following steps with respect to each ambient monitor required by subsection 60 (1)
1 For each two-week period in the previous three calendar years record one of the followingi if the monitor indicates a measurement of a concentration of benzene record the
measured concentration of benzeneii if the monitor indicates that the measurement of the concentration of benzene was below
the detection limit of the monitor record half of the detection limit of the monitor as theconcentration of benzene or
iii if the monitor provides no indication of any measurements with respect to theconcentration of benzene do not record a concentration but instead record an explanationof why no measurement of benzene was taken
2 Translate each concentration recorded in paragraph 1 to its equivalent natural logarithm3 Calculate the mean of all of the values translated in paragraph 24 Calculate the square of the standard deviation of all of the values translated in paragraph 2
using the following equation
Where S is the standard deviation m is the number of two-week average concentrations recorded in
paragraph 1 xi is each value translated in paragraph 2 and X is the value calculated in paragraph 3
(3) Subject to subsection (4) no later than March 31 in each year following the fourth full calendaryear after this section applies in respect of the petroleum refining facility the baseline mentionedin subsection (1) shall be re-determined by performing the steps set out in subsection (2) usingconcentrations of benzene measured by the monitor in the previous three calendar years(4) Subsection (3) does not apply if the concentration of benzene measured by the monitoraveraged over the calendar year mentioned in subsection (3) is higher than(a) if no re-determination has previously been made under subsection (3) the baseline
determined under subsection (2) or(b) if a re-determination has previously been made under subsection (3) the most recent reshy
determination under subsection (3)(5) The results of each step required to be performed under subsections (2) and (3) shall berecorded
Statistical analysis of benzene measurements 62 (1) For the purpose of this section reference to a statistically significant increase in the
concentration of benzene is a reference to the determination of whether the concentration of benzene measured at a monitor during a calendar year is higher than the concentration of benzene
Ontario Ministry of the Environment and Climate Change 228
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 measured at the monitor during the three-year period in which the most recent baseline wasdetermined under section 61 and if so whether the increase in concentration is statistically significant
(2) A registered person shall ensure that a determination of whether a statistically significantincrease in the concentration of benzene has occurred in a year is made in accordance with thissection
(3) No later than March 31 in each year following the fourth full calendar year in which this sectionapplies in respect of a petroleum refining facility a statistical analysis shall be completed byperforming the following steps with respect to each ambient monitor identified as adequate under section 60
1 For each two-week period in the previous calendar year record one of the followingi if the monitor indicates a measurement of a concentration of benzene record the
measured concentration of benzeneii if the monitor indicates that the measurement of the concentration of benzene was below
the detection limit of the monitor record half of the detection limit of the monitor as theconcentration of benzene or
iii if the monitor provides no indication of any measurements with respect to theconcentration of benzene do not record a concentration but instead record an explanationof why no measurement of benzene was taken
2 Translate each two-week average recorded in paragraph 1 to its equivalent natural logarithm3 Calculate the mean of all of the values translated in paragraph 24 Calculate the square of the standard deviation of all of the values translated in paragraph 2
using the following equation
WhereS is the standard deviationn is the number of two-week average concentrations recorded in paragraph 1x i is each value translated in paragraph 2 andX is the value calculated in paragraph 3
5 Calculate the test statistic using the following equation
Where T is the test statistic Y is the value calculated in paragraph 3 X is the most recent value calculated in paragraph 3 of subsection 61 (2) S1 is the most recent value calculated in paragraph 4 of subsection 61 (2) S2 is the value calculated in paragraph 4 m is the most recent number of two-week average concentrations recorded in
paragraph 1 of subsection 61 (2) and n is the number of two-week average concentrations recorded in paragraph 1
6 Calculate the degrees of freedom using the following equation
Where
(v) is the degrees of freedom andS1 S2 m and n have the same meanings as set out in paragraph 5
229Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 7 Find the value calculated in paragraph 6 in Column 1 of Table 6-62 and determine the value
set out opposite that value in Column 28 Determine whether there has been a statistically significant increase in the concentration of
benzene at the monitor by assessing whether the value calculated in paragraph 5 exceeds thevalue determined under paragraph 7
(4) A registered person shall ensure that the following information is recorded for each monitor1 The results of each step performed for the purpose of this section2 Any changes to the baseline for the monitor in accordance with section 61
TABLE 6-62 Statistical Analysis Item Column 1
Degrees of Freedom (v) Column 2 Test Statistic (T) with level of significance () =
00005 1 1 6366 2 2 3160 3 3 1292 4 4 8610 5 5 6869 6 6 5959 7 7 5408 8 8 5041 9 9 4781 10 10 4587 11 11 4437 12 12 4318 13 13 4221 14 14 4141 15 15 4073 16 16 4015 17 17 3965 18 18 3922 19 19 3883 20 20 3850 21 21 3819 22 22 3792 23 23 3768 24 24 3745 25 25 3725 26 26 3707 27 27 3690 28 28 3674 29 29 3659
230Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Item Column 1 Degrees of Freedom (v)
Column 2 Test Statistic (T) with level of significance () =
00005 30 30 3646 31 40 3551 32 60 3460 33 120 3373 34 infin 3291
Notification ndash ambient monitoring 63 (1) A registered person shall ensure that as soon as practicable a provincial officer is
notified in writing if it is determined under section 62 that there has been a statistically significantincrease in the concentration of benzene at an ambient monitor required by subsection 60 (1)
(2) No later than six months after notice is required to be given under subsection (1) theregistered person shall ensure that the following information is submitted in writing to a provincialofficer
1 The measured and calculated values relating to the statistically significant increase in theconcentration of benzene
2 An explanation of the suspected cause of the statistically significant increase in theconcentration of benzene
3 A description of any steps taken or that will be taken to prevent minimize or reduce the risk offuture statistically significant increases in the concentration of benzene if any
4 An indication of the date by which each step mentioned in paragraph 3 will be implemented5 A written explanation of how each step mentioned in paragraph 3 will prevent minimize or
reduce the risk of any future statistically significant increases in the concentration of benzene
PART X ndash COMPLAINTS RECORDS AND REPORTINGComplaints procedure 64 (1) A registered person shall ensure that the following steps are taken to properly respond toeach complaint that relates to a matter addressed in this industry standard
1 A prompt response is made to the person who made the complaint unless the personrequests that a response not be made or fails to provide contact information
2 Action is taken to remedy the cause of the complaint3 A written record of the complaint is prepared that includes the following information
i A description of the complaintii The date and time that the complaint was receivediii If the complaint relates to a discharge of a contaminant to air the date time and
suspected cause of the complaint including whether any activities at the facility may havegiven rise to the complaint
iv If the complaint relates to a discharge of a contaminant to air ambient temperature at thetime of the discharge to which the complaint relates
v If the complaint relates to a discharge of a contaminant to air the approximate winddirection and wind speed at the time of the discharge to which the complaint relates
vi If the complaint relates to a discharge of a contaminant to air the general weatherconditions at the time of the discharge to which the complaint relates
vii A description of any actions taken to address the matter to which the complaint relatesand the date each action was completed
231Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 viii A description of any actions taken to prevent a similar future complaint and the date each
action was completed(2) If a complaint mentioned in subsection (1) relates to the discharge of a contaminant to air from
the petroleum refining facility the registered person shall ensure that the Ministryrsquos Spills Action Centre is notified of the complaint as soon as practicable after the complaint is made
(3) No later than five days after notification is required to be given under subsection (2) theregistered person shall ensure that the record mentioned in paragraph 3 of subsection (1) issubmitted to a provincial officer
Annual summary reports 65 (1) On and after January 1 2019 a registered person shall ensure that annual summaries
are prepared and reviewed in accordance with this section (2) No later than March 31 each year the following summaries shall be prepared and the
information therein shall pertain to the preceding calendar year 1 A table labelled ldquoImplementation Summary Tablerdquo that for the calendar year sets out
i A summary of the provisions of this industry standard that apply to the petroleum refiningfacility in accordance with section 2
ii For each provision mentioned in subparagraph iA an indication of the date on which the provision applies to the petroleum refining
facility and
B if compliance with the provision has been achieved an indication of the date onwhich compliance was achieved
2 A report entitled ldquoAnnual Summary of Component Leak Detection and Repairsrdquo that sets outi the number of component leak surveys conducted during the calendar year at the
petroleum refining facility in accordance with subsection 39 (1)ii the start date and end date of each component leak survey conducted at the petroleum
refining facility during the calendar yeariii if less than three component leak surveys were conducted during the calendar year
A the combined annual percentage of leaking valves during the previous calendar yearcalculated in accordance with subsection 47 (1) and
B the annual average concentration of VOCs from leaking components during theprevious calendar year calculated in accordance with subsection 47 (2)
iv for each process unit at the petroleum refining facility that contains one or morecomponents required to be recorded under subsection 38 (1) the following information
A The name and a description of the process unitB Each date on which the process unit did not operate and the duration for which it did
not operateC The total number of components in the process unitD The number of inaccessible components and number of components that have been
identified as unsafe components in the process unitE The start date and end date of each component leak survey during the calendar year
that assessed a component in the process unitF The number of components in the process unit that were surveyed in the calendar
year and the method used to assess each componentG The number of components expressed as a percentage of the total components in
the process unitthat had leaks at the following concentrations1 Greater than 0 and less than or equal to 1000 ppm of VOCs by volume2 Greater than 1000 ppm and less than or equal to 5000 ppm of VOCs by
volume232 Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 3 Greater than 5000 ppm and less than or equal to 10000 ppm of VOCs by
volume4 Greater than 10000 ppm and less than or equal to 25000 ppm of VOCs by
volume5 Greater than 25000 ppm of VOCs by volume
H A summary by component type of the repairs to components made during thecalendar year including the shortest longest and average time between detecting aleak and repairing the component so that the concentration of VOCs discharged to airfrom the component was less than 1000 ppm by volume
I A summary by component type of the number of repairs to components in theprocess unit each calendar year for the shorter of1 the previous 10 calendar years and2 the calendar years since the date the petroleum refining facility was first
registered to this industry standardJ The number of components in the process unit expressed as a percentage of the
total components in the process unit that have been repaired more than one time inthe calendar year so that the concentration of VOCs discharged to air from thecomponent is less than 1000 ppm by volume
K The number of valves replaced with low-emission valves and the number of valvesreplaced with low emission valve packing during the calendar year and an indicationof how many of the valves were required by subsection 44 (6) and section 46 to bereplaced
v The most recent report mentioned in subsection 44 (4) for the petroleum refining facility3 A report entitled ldquoAnnual Summary of Defects and Repairs for Storage Vesselsrdquo that sets out
for each storage vessel identified on the list required by subsection 9 (3)i a summary of the information required by subsection 20 (2) paragraphs 5 to 7 of section
22 and subsection 23 (2)ii an indication of any changes in the number of defects or repairs from the summary of the
previous yeariii the number of times an event that caused one or more defects occurred at the facility
during the calendar yeariv an indication of whether any of the events mentioned in subparagraph iii were of particular
concernv an indication of whether the number of events mentioned in subparagraph iii suggest a
recurring issue both in respect of the calendar year and in respect of previous calendaryears and
vi an explanation of any actions taken to address the events mentioned in subparagraph iii4 A report entitled ldquoAnnual Summary of Air Emissions from Industrial Sewage Systemsrdquo that sets
outi for each primary oil-water separator at the petroleum refining facility a summary of the
information required by paragraph 2 or 3 of subsection 30 (1) paragraphs 5 to 8 of section31 and subsection 32 (2) and
ii a summary of the information required by subparagraph 2 ii of section 345 A report entitled ldquoAnnual Benzene-containing Product Loading Reportrdquo that sets out a
summary of the information required by subsection 35 (1) if any6 A report entitled ldquoAnnual Ambient Monitoring Report for Petroleum Refining ndash Industry
Standardrdquo that sets outi a map showing the location of each monitor required by subsection 60 (1) the information
required by clause 60 (4) (d) and other topographical information including any nearbywater bodies roadways and adjacent land uses
ii for each monitor required by subsection 60 (1)
233Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 A the information required by subsection 60 (6)B the results of calculations required by section 62 to identify whether a statistically
significant increase in the concentration of benzene occurredC a summary showing the annual average benzene concentration results from the time
that the monitor was first required by subsection 60 (1)iii a summary of the information required by section 63
7 A summary that for the calendar year sets out changes made to the Operating ParameterSummary Table and summarizes the information that was required to be updated inaccordance with subsection 52 (6)
8 A table labelled ldquoPerformance Summary Tablerdquo that for the calendar year sets outi a summary of all notifications required to be given under subsections 8 (1)ii a summary of the number of contraventions of subsections 11 (1) and 26 (1) andiii an indication of whether an order has been given to the petroleum refining facility under
subsection 52 (5) or section 589 A table labelled ldquoAnnual Summary of Changes to Source Informationrdquo that for the calendar
year sets out the table required by section 55 with an additional column setting out for eachpiece of equipment an indication if the information in columns 1 or 2 has changed frominformation set out in the previous calendar year If no changes have occurred in the calendaryear the words ldquono changerdquo shall be set out in the additional column
10 A table labelled ldquoComplaint Summary Tablerdquo that sets out the total number of complaintsdescribed in section 64 that have been received by the petroleum refining facility in thecalendar year and compares the number to the number of complaints received by thepetroleum refining facility in the previous calendar year
(3) No later than March 31 each year the highest-ranking individual at the petroleum refiningfacility shall certify in writing that the summaries required by paragraphs 1 to 10 of subsection (2)have been prepared in accordance with this industry standard and that the information contained in the summaries is
(a) accurate and complete and(b) true to the best of his or her knowledge(4) The summary tables required by paragraphs 1 and 8 of subsection (2) shall be(a) made available for examination by any person without charge by ensuring it is posted and
available on the website for the petroleum refining facility and by making it available duringregular business hours at the place to which the summaries relate and
(b) given without charge to any person within 15 days after the person requests it
Public reporting ndash ambient monitoring 66 (1) On and after January 1 2018 a registered person shall ensure that the following
information is made available for examination by any person without charge by ensuring it isposted and available on a website for the petroleum refining facility and by making it available during regular business hours at the place to which the information relates
1 A map showing the location of each monitor required by subsection 60 (1) the informationrequired by clause 60 (4) (d) and other relevant topographical information including any nearbywater bodies roadways and adjacent land uses
2 A table showing the information required by subsection 60 (6) for each monitor for the calendaryear updated in accordance with subsection (2) and set out in a manner that can beunderstood by persons without specialized scientific training
3 A copy of the report mentioned in paragraph 6 of subsection 65 (2)(2) No later than 60 days after a two-week air sample is taken by a monitor required by
subsection 60 (1) the information required by subsection 60 (6) shall be added to the table mentioned in paragraph 2 of subsection (1)
234Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Records 67 (1) Subject to subsection (2) a registered person shall ensure that each record required by
this industry standard is (a) retained at the petroleum refining facility for at least five years and(b) if applicable maintained on the website for the petroleum refining facility for at least five
years(2) A registered person shall ensure that each record mentioned in section 66 is retained at the
petroleum refining facility and maintained on the website for the petroleum refining facility for at least10 years
(3) A person required to make a record available under subsections (1) or (2) shall make therecord available
(a) to a provincial officer or Director upon request as soon as practicable and(b) in a form approved by the Director including if required by the Director an electronic format
specified by the Director(4) In addition to the records mentioned in subsection (1) a registered person shall ensure that
each document relating to the recommendations of the manufacturer for each device at the petroleum refining facility with respect to the use operation and maintenance of the device isretained for the period during which the device is used or operated
(5) In addition to the records mentioned in subsection (1) if a component is in the opinion of thehighest ranking individual at a petroleum refining facility an unsafe component the registered person shall ensure that each document relating to the opinion of the highest ranking individual isretained at the petroleum refining facility for the period during which the component is in benzene service
235Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Appendix 6-A All Contaminants
Item Column 1 CAS No
Column 2 Contaminant
1 71-43-2 Benzene 2 50-32-8 Benzo(a)pyrene
Appendix 6-B Benzene
Item Column 1 CAS No
Column 2 Contaminant
1 71-43-2 Benzene
Appendix 6-C Benzo(a)pyrene
Item Column 1 CAS No
Column 2 Contaminant
1 50-32-8 Benzo(a)pyrene
236Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Appendix 6-D Portable Gas Detector - Methodology and Instrumentation
Definitions 1 (1) For the purpose of this Appendix 6-D
ldquocalibration gasrdquo means a VOC used to adjust an instrument reading to a known value ldquocalibration precisionrdquo means the degree of agreement between a known concentration and an instrumentrsquos measurements of a known concentration ldquocylinder calibration gasrdquo means a calibration gas that is packaged in a cylinder ldquocomponent interfacerdquo means the surface of a component where a leak may occur ldquoresponse factorrdquo means the ratio of the known concentration of a VOC to an instrumentrsquos measurements of a known concentration ldquoresponse timerdquo means the time from introducing a VOC to an instrument to the time at which 90 percent of the corresponding final value is reached as displayed on the instrument readout ldquozero gasrdquo means a gas containing less than 10 ppmv VOCs that is used for calibrating the zero point of an instrument
(2) For the purposes of the procedures set out in this Appendix the calibration gas used shall be(a) if the portable gas detector uses flame ionization to detect VOCs methane and(b) if the portable gas detector uses photoionization technologies isobutylene gas of a
concentration that is between 900 ppm and 1100 ppm by volume(3) Despite clause (2) (a) a calibration gas used with a portable gas detector that uses flame
ionization may be a VOC other than methane if (a) the VOC has a published response factor and(b) the portable gas detector has been adjusted using the response factor to display a
concentration that is the methane-equivalent concentration of the VOC(4) For the purposes of subsections 2 (3) and (4) the calibration gas used with a portable gas
detector that uses flame ionization to detect VOCs shall have a methane or methane equivalentconcentration that is between 900 ppm and 1100 ppm by volume
VOCs Leak Measurement - Instrument Requirements 2 (1) As required by clause 3 (a) of this industry standard a portable gas detector shall meet the
following criteria 1 The portable gas detector shall be designed to detect VOCs The portable gas detector shall
use flame ionization or photoionization technologies to detect VOCs2 The portable gas detector shall be capable of measuring concentrations of VOCs that are as
low as 100 parts per million by volume3 The portable gas detector shall be capable of measuring and displaying to at least plusmn25
percent of 100 parts per million by volume4 The probe of the portable gas detector shall be fitted with a glass wool plug or filter to prevent
plugging of the portable gas detector5 The portable gas detector shall be equipped with an electrically-driven pump to ensure that a
sample is provided to the detector at a constant flow rate The nominal sample flow rate asmeasured at the sample probe tip shall be between 020 and 20 litres per minute
6 The portable gas detector shall be equipped with a probe probe extension or sampling systemnot to exceed 64 mm (14in) in outside diameter with a single end opening for admission ofsample
7 The portable gas detector shall be intrinsically safe for operation in explosive air8 The response factor of the portable gas detector shall be less than 109 The calibration precision of the portable gas detector determined in accordance with
subsection (3) shall be equal to or less than 10 per cent of the calibration gas value
Ontario Ministry of the Environment and Climate Change 237
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 10 The response time of the portable gas detector determined in accordance with subsection (4)
shall be equal to or less than 10 seconds(2) A portable gas detector shall be calibrated using a zero gas and a calibration gas and if the
portable gas detector uses flame ionization to detect VOCs it shall be calibrated (a) if the portable gas detector is not capable of multi-point calibration by single point calibration
using a calibration gas that has a methane or methane equivalent concentration of between900 ppm and 1100 ppm by volume or
(b) if the portable gas detector is capable of multi-point calibration by multi-point calibration using(i) for the lowest span a calibration gas that has a methane or methane equivalent
concentration of between 900 ppm and 1100 ppm by volume and(ii) for the highest span a calibration gas that has a methane or methane equivalent
concentration of between 9000 and 11000 ppm by volume(3) The calibration precision shall be determined by taking the following steps1 Introduce a calibration gas to the probe of the portable gas detector and record the observed
instrument reading2 Introduce a zero gas to the probe of the portable gas detector until a stable reading is
obtained3 Repeat the steps set out in paragraphs 1 and 2 two more times for a total of three repetitions4 Calculate the average algebraic difference between the three instrument readings taken under
paragraph 1 and the known concentration of the calibration gas5 Divide the average difference mentioned in paragraph 4 by the known concentration of the
calibration gas mixture and multiply the result by 100(4) The portable gas detector response time shall be determined by taking the following steps1 Introduce zero gas to the probe of the portable gas detector2 When the instrument reading for the zero gas has stabilized quickly introduce a calibration
gas to the probe of the portable gas detector3 After introducing the calibration gas measure and record the time required for the portable gas
detector to attain a reading of 90 percent of the known concentration of the calibration gas4 Repeat the steps set out in paragraphs 1 2 and 3 two more times for a total of three
repetitions5 Determine the response time of the portable gas detector by taking the average of the three
values recorded under paragraph 4(5) A cylinder calibration gas shall not be used for the purposes of this section unless(a) the concentration of the cylinder calibration gas has been certified by the manufacturer of the
gas to be accurate within two per cent and(b) the date is earlier than the expiry date set out on the label of the cylinder calibration gas
VOCs Leak Measurement - Methodology 3 (1) As required by clause 3 (a) of this industry standard a portable gas detector shall be used inthe following manner
1 At the beginning of each day on which a portable gas detector is used the following stepsshall be taken
i Assemble a portable gas detector that meets the criteria set out in subsection 2 (1) of thisAppendix
ii Warm up the portable gas detector according to the manufacturerrsquos instructionsiii Determine and record
A [Revoked]B the calibration precision of the portable gas detector in accordance with subsection 2
(3) of this Appendix and
238Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018 C the portable gas detector response time in accordance with subsection 2 (4) of this
Appendixiv [Revoked]v [Revoked]vi If a cylinder calibration gas was used for any of the steps in subparagraphs iii to v record
the manufacturer expiry date and concentration of the cylinder calibration gas2 To assess a component for leaks the following steps shall be taken
i1 Zero the instrument to adjust for the background concentration of VOCsi Place the probe of the portable gas detector at the component interfaceii Move the probe along the component interface periphery placing the probe as close as
possible to the component interface periphery while observing the portable gas detectorreadout
iii If an increased instrument reading is observed slowly sample the component interfaceuntil the maximum reading is obtained
iv Leave the probe at this maximum reading location for approximately two times theportable gas detector response time
v Record the maximum concentration of VOCs detected by the portable gas detector
(11) At the end of each day on which a portable gas detector is used the following steps shall betaken
1 Determine and recordi the calibration precision of the portable gas detector in accordance with subsection 2 (3)
of this Appendix andii the portable gas detector response time in accordance with subsection 2 (4) of this
Appendix2 If a cylinder calibration gas was used for any of the steps in paragraph 1 record the
manufacturer expiry date and concentration of the cylinder calibration gas
(2) If the component is a valve for the purpose of subparagraph 2 i of subsection (1) place theprobe at the component interface where the stem exits the packing gland and sample the stemcircumference Also place the probe at the component interface of the packing gland take-up flange seat and sample the periphery In addition sample valve housings of multipart assembly atthe surface of all component interfaces where a leak could occur
(3) If the component is a connector or pressure relief device that is not designed to discharge toair for the purpose of subparagraph 2 i of subsection (1) place the probe at the outer edge of the flange-gasket component interface and sample the circumference of the flange Sample other typesof non-permanent joints (such as threaded connections) in a similar manner
(4) If the component is a pump or compressor for the purpose of subparagraph 2 i of subsection(1) move the probe around the circumference of the outer surface of the pump or compressor shaftand seal component interface If sampling a rotating shaft position the probe within one centimetreof the shaft-seal component interface If the housing configuration prevents a complete traverse ofthe shaft periphery sample all accessible portions Sample all other joints on the pump or compressor housing where leakage could occur
(5) If the component is a pressure relief device that is equipped with an enclosed extension orhorn and that is designed to discharge to air for the purpose of subparagraph 2 i of subsection (1)place the probe inlet at approximately the centre of the exhaust area to the air
(6) If the component is an open-ended valve for the purpose of subparagraph 2 i of subsection(1) place the probe inlet at approximately the centre of the opening to the air
(7) If the component is a sample point instrumentation system or agitator for the purposes ofsubparagraph 2 i of subsection (1) move the probe around the circumference of the outer surface ofthe component
239Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Appendix 6-E Optical Gas Imaging - Methodology and Instrumentation
Optical Gas Imagingndash OGI Instrument Requirements 1 (1) As required by clause 3 (b) of this industry standard an OGI instrument shall meet the
following criteria 1 The OGI instrument must be designed to make visible VOC air emissions that would normally
be invisible to the naked eye2 The OGI instrument must be portable3 [Revoked]4 The OGI instrument must be capable of recording and storing images5 The OGI instrument must record the date time and an identifier code for each image taken by
the instrument6 [Revoked]
(2) The following information must be present at the petroleum refining facility where the OGIinstrument mentioned in subsection (1) is used
1 An operating manual that sets out how to operate the OGI instrument2 [Revoked]3 A written record of the detection limits of the OGI instrument for methane propane hexane
and benzene4 A written record of the maximum image storage capacity of the OGI equipment
Optical Gas Imagingndash Methodology 2 (1) As required by clause 3 (b) of this industry standard an OGI instrument shall be used in a
manner that meets the requirements set out in this section (2) An OGI instrument used in the performance of a component leak survey shall be calibrated at
the frequency set out in the operating manual (3) An OGI instrument used in the performance of a component leak survey shall operate
properly (4) Before using an OGI instrument on a day the maximum distance at which the OGI instrument
will detect VOCs shall be determined and recorded (5) On the day mentioned in subsection (4) the distance between an OGI instrument and the
component which is being assessed by the OGI instrument shall be no greater than the distancedetermined in accordance with that subsection
(6) If an OGI instrument is capable of determining the concentration of VOCs the concentrationshall be determined accurately
240Ontario Ministry of the Environment and Climate Change
Tracking
Version 20
Date
Created February 27th 2018
Publishing Minister
Ballard
Petroleum Refining
Version 10
- Industry Standard
Created July 27 2016 Murray
Petroleum Refining
- Industry Standard
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
Appendix 6-F Fixed Leak Detection System - Methodology and Instrumentation Fixed leak detection system ndash Instrument Requirements
1 As required by clause 3 (c) of this industry standard a fixed leak detection system shall meetthe following criteria
1 The fixed leak detection system shall be located close enough to a component to measure theconcentration of VOCs discharged from the component
2 The fixed leak detection system shall be located no farther from a component mentioned inparagraph 1 than the distance set out in the operating and maintenance manual provided by amanufacturer or supplier of fixed leak detection systems
3 The fixed leak detection system shall be capable of sampling the air at least one time every 60minutes
4 The results of the sampling and analysis shall be stored in an electronic data acquisitionsystem
Record of Publications for Petroleum Refining - Industry Standard
241Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
CHAPTER 7 - PETROCHEMICAL ndash INDUSTRY STANDARD
Version 20 Created February 27th 2018
PREAMBLE
bull This technical standard is an industry standard as defined in section 1 of O Reg 41905
bull With respect to facilities this industry standard applies to every facility that is part of a classidentified by NAICS code 325110 (Petrochemical Manufacturing)
bull With respect to contaminants this industry standard applies to contaminants listed in Appendix 7shyA
bull Each source of contaminant associated with NAICS code 325110 that discharges a contaminantmentioned in the above bullet has been considered in development of this industry standard Assuch a person that meets the criteria set out in subsection 42 (1) or subsection 44 (1) of O Reg41905 is in general exempt from Part II of the Regulation in respect of the facility andcontaminant(s) for which it is registered In other words there is no need to model in a facilityrsquosEmission Summary and Dispersion Modelling report discharges of a registered contaminant fromany source of contaminant associated with NAICS code 325110 (For more information please seethe Introduction to the Technical Standards Publication)
bull In accordance with subsection 38 (3) of O Reg 41905 compliance with this industry standard inaccordance with subsection 42 (5) or subsection 44 (3) of O Reg 41905 may reduce theregulatory burden applicable to facilities in this class
bull This standard contains requirements that relate to sources of contaminant associated with thefollowing
bull storage vesselsbull equipment leaksbull sewage treatment operationsbull truck and railcar product loading racks and marine vessel loading berths
bull For this industry standard with respect to benzene the publication of this industry standardindicates that the following criteria of paragraph 3 of subsection 38 (1) of O Reg 41905 are met
(a) with respect to at least two facilities located in Ontario to which this standard applies it is nottechnically feasible to comply with section 20 of O Reg 41905 and
(b) compliance in accordance with subsection 42 (5) of O Reg 41905 with this standard
(i) is technically and economically feasible with respect to at least one facility located inOntario to which this industry standard applies
(ii) will permit efforts that would otherwise be made to comply with section 19 or 20 of O Reg41905 to be put to better use to protect the natural environment having regard to clause(a) and
242Ontario Ministry of the Environment and Climate Change
Technical Standards to Manage Air Pollution Version 51 ndash February 27th 2018
(iii) including this industry standard in the ldquoTechnical Standards to Manage Air Pollutionrdquo ismore efficient than having the Director consider separate requests under section 32 of OReg 41905 to set site-specific standards for the contaminant that would otherwise applyto facilities in the class
243Ontario Ministry of the Environment and Climate Change