Models 11000, 11001, 11002, 11003, T00074 IMPORTANT SAFETY INSTRUCTIONS Read all warnings and instructions. Save these instructions. The most up-to-date warnings and instructions are available at www.axon.com MMU0042 Rev: L August 2020 TASER X26P CEW User Manual

TASER X26P CEW User Manual

  • Upload
    others

  • View
    18

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TASER X26P CEW User Manual

Models 11000, 11001, 11002, 11003, T00074

IMPORTANT SAFETY INSTRUCTIONSRead all warnings and instructions. Save these instructions.

The most up-to-date warnings and instructions are available at www.axon.com

MMU0042 Rev: L

August 2020

TASER X26P CEWUser Manual

Page 2: TASER X26P CEW User Manual

Contents

i

1 Chapter 1: Warnings1 Important Safety and Health Information

2 LASER Information

2 Use of Force Policy

3 Firmware Update

4 Chapter 2: General Information4 What is the TASER X26P CEW?

4 Neuro Muscular Incapacitation (NMI)

5 Basic X26P CEW Electrical Theory

6 Chapter 3: Features6 X26P CEW Features

6 Safety Switch

7 LASER

7 Mechanical Sights

7 Performance Power Magazine (PPM) Battery Pack

8 Changing the Battery Pack

8 Tactical Performance Power Magazine (TPPM) Battery Pack

9 eXtended Performance Power Magazine (XPPM) Battery Pack

9 Automatic Shut-Down Performance Power Magazine (APPM) Battery Pack

9 ReplacingtheAPPMwithaDifferentBatteryPack

10 eXtended Automatic Shut-Down Performance Power Magazine (XAPPM) Battery Pack

10 Signal Performance Power Magazine (SPPM) Battery Pack (Model T00074)

10 Automatic Shut-Down Option

10 SPPM Transmit in Safe Option

11 Signal Mute Mode

11 Updating the SPPM Firmware

Page 3: TASER X26P CEW User Manual

ii

TASER X26P CEW User Manual

Contents

11 Advanced Central Information Display (CID)

11 SystemStatusIcons

12 BatteryLevelIcons

13 SparkDuration

13 SampleCIDDisplays

14 LED Flashlight

14 Selector Switch (LASER and LED Flashlights)

15 Enabling SPPM Signal Mute Mode

16 Trigger Switch

17 Chapter 4: Cartridges & CEW operation17 Removing the Shipping Cover from the Cartridge

17 15, 21, LS, and XP25 TASER Cartridges

18 AFID

18 Load the TASER Cartridge

18 Loading

19 Unloading

19 Aiming and Probe Placement

20 “Silence is Golden”

20 Audible Pulse Rate Changes

20 PotentialCausesofReducedorNoEffectiveness

21 Electrodes

21 Drive-Stun Backup

22 RecommendedDrive-StunAreasforMaximumEffect

23 Chapter 5: Maintenance/Troubleshooting23 Function Test

23 Function Test Instructions

24 What to Do following CEW Use

24 Considerations for Handling Used Probes

24 EffectsonAnimals

24 Police/Military K-9 Caution

25 Downloading Firmware Revisions

25 Dataport Download Kit

25 USB Connection Status

25 EvidenceSyncOfflineSoftware

25 Trilogy Log

Page 4: TASER X26P CEW User Manual

iii

TASER X26P CEW User Manual

Contents

26 Event Log

26 Pulse Log

26 Engineering Log

27 Time Synchronization

27 X26P CEW Maintenance and Care

27 Dropped or Wet X26P CEW

29 Online Troubleshooting Guide

29 Product Returns

30 Chapter 6: Optional Accessories30 Axon Evidence Services

30 EvidenceSyncOfflineSoftware

30 TASER CAM HD Recorder

31 Holsters

32 Chapter 7: Additional items32 Additional information

32 Axon Academy

32 Medical Research

33 Radio Waves

34 DeclarationofConformity

34 Compliance Marks

Page 5: TASER X26P CEW User Manual

1

Chapter 1: Warnings

Important Safety and Health InformationRead,understandand follow themost currentproductwarnings, safety instructions, and trainingmaterials. All product warnings are not included in this Manual. A Product Warnings document is includedwith thisconductedenergyweapon (CEW)andthemostcurrentwarningsarepostedonourwebsiteatwww.axon.com.ThemostcurrenttrainingmaterialsareavailablebycontactingAxon’sTrainingDepartment.DonotattempttousethisCEWuntilyouhavecompletedtrainingwithanAxonEnterprise,Inc.(Axon)CertifiedTASERInstructor.

! WARNING!

CompletetrainingfirstSignificantdifferencesexistbetweeneachoftheTASERCEWmodels.DonotuseorattempttouseanyCEWmodelunlessyouhavebeentrainedandcertifiedbyaCertifiedTASERInstructoronthatparticularmodel.

Read and obeyRead,study,understand,andfollowallinstructions,warnings,information,trainingbulletinsandrelevantTASERtrainingmaterialsbeforeusingtheTASERX26PCEW.Failuretocomplywiththeproductinstructions,warnings,information,trainingbulletins,andTASERtrainingmaterialscouldresultindeathorseriousinjuryto the user, force recipient, and others.

Obey applicable lawsUseofCEWsmustbelegallyjustifiedandcomplywithapplicablefederal,state,andlocallawsandregulations.The decision to use a CEW in a particular manner or circumstance must follow applicable law enforcement agencyGuidance.

Inprobe-deploymentmode,TASERCEWsaredesignedtotemporarilyincapacitateapersonfromasaferdistancewhilereducingthelikelihoodofseriousinjuriesordeath.Whenusedasdirected,TASERCEWshavebeenfoundtobesaferandmoreeffectivethanothertraditionaluse-of-forcetoolsandtechniques.However,itisimportanttorememberthattheuseofforceandphysicalincapacitation,bytheirverynature,involveriskthatsomeonewillgethurtormayevendiefromfactorsthatinclude,butarenotlimitedto:physicalresistance,exertion,individualsusceptibilities,and/orunforeseencir-cumstances.Anyuseofforce,includingtheuseofaCEW,orphysicalexertioninvolvesrisksthatapersonmaygethurtordie.

Page 6: TASER X26P CEW User Manual

2

TASER X26P CEW User Manual

Chapter 1: Warnings

LASER Information

! WARNING!

LASER RADIATION

DONOTSTAREINTOBEAM

CLASS 2 LASER PRODUCT

! WARNING!

LASER RADIATION

AVOID DIRECT EYE EXPOSURE

CLASS 3R LASER PRODUCT

! WARNING!

AVOID EXPOSURE – LASER RADIATION IS EMIT-TED FROM THIS APERTURE

! CAUTION! RADIATION EXPOSUREUseofcontrolsoradjustmentsorperformanceofproceduresother than thosespecifiedhereinmayresultinhazardousradiationexposure.

Use of Force PolicyEachagencyisresponsibleforcreatingitsownuse-of-forcepolicyanddetermininghowTASERCEWsfititsuse-of-forcematrixbasedonlegalandcommunitystandards.Makesureyouragencyhasause-of-forcepolicythataddressesTASERCEWuseandthatthispolicyisclearlyaddressedduringend-usertraining.

Page 7: TASER X26P CEW User Manual

3

TASER X26P CEW User Manual

Chapter 1: Warnings

Firmware UpdateBeforeusingyourX26PCEW,confirmwithyourarmorerorotherqualifiedpersonthattheX26Pfirm-ware has been updated.

Page 8: TASER X26P CEW User Manual

4

Chapter 2: General Information

What is the TASER X26P CEW?TheX26PCEWisafirmware-upgradableweaponmanufacturedbyAxonEnterprise,Inc.

The X26P CEWuses a replaceable cartridge containing compressed nitrogen to deploy two smallprobesthatareattachedtotheX26PCEWcartridgebyinsulatedconductivewires.Thecartridgesareavailablewithvariouswirelengthsfrom15to25feet(4.6to7.6meters).Saleofcartridgeswithwirelengthlongerthan15feetislimitedtolawenforcementandmilitaryonly.

TheX26PCEW’sTrilogylogcanbeuploadedsecurelytoAxonEvidence(Evidence.com)services.TheX26PCEWhasaninternalmemorythatstorestheoperatingfirmwareandadeploymentrecord.SeeTrilogy Log (Chapter5) for more details. Those who do not have an Axon Evidence account can use theOfflineEvidenceSyncsoftwaretodownloadasimplifiedlogtoalocalcomputer.

TheX26PCEWhasanestimatedusefullifeoffiveyears.

Neuro Muscular Incapacitation (NMI)

TASERtechnologyisdesignedtouseelectricalimpulsessimilartothoseinyourbody’snervoussystemtocausestimulationofthesensoryandmotornerves.NeuroMuscularIncapacitation(NMI)occurswhenaCEWisabletocauseinvoluntarystimulationofboththesensorynervesandthemotornerves.Itisnotdependentonpainandcanbeeffectiveonsubjectswithahighlevelofpaintolerance.

Previous generations of stun guns primarily affected the sensory nerves only, resulting in paincompliance. A subject with a very high tolerance to pain (e.g., a drug abuser, person in seriouspsychologicaldistress,oratrained,focusedfighter)maynotbeaffectedbythepainormightbeabletofightthroughthepainofatraditionalstungun.

Page 9: TASER X26P CEW User Manual

5

TASER X26P CEW User Manual

Chapter2:GeneralInformation

Basic X26P CEW Electrical Theory• Electricitymustbeabletoflowbetweentheprobestodeliveranelectricalchargeandwillgenerally

follow the path of least resistance.

• Generally,thegreaterthespreadbetweentheprobesonthetarget,thegreatertheeffectiveness.

• Electricitywillgenerallynotpasstoothersincontactwiththesubjectunlesscontactismadedirectlybetween or on the probes, or the wires are touched.

• Electricitycanarcthroughmostclothing,andevensomebullet-resistantmaterials.

• Exposure to water will not cause electrocution or increase the power to the subject. The electrical chargeisfixedinsidetheTASERCEW,andwillnotincreasesignificantlyevenwithenvironmentalchanges.

• TheCurrentMeteringtechnologyisdesignedtodeliveroptimalcharge.

Page 10: TASER X26P CEW User Manual

6

X26P CEW FeaturesGettoknowtheX26PCEW:

Note:Theserialnumberislocatedinsidethecartridgebay.

EnsuretheCEWisunloaded,thesafetyisinthedown(SAFE)position,andyourfingersareawayfrom the trigger before reading the serial number.

Safety SwitchAmbidextroussafetycanbeoperatedfromeithersideoftheCEW.

• Safety switch down(SAFE).

• Safety switch up(ARMED)andreadytodeploy.

• Do not block thesafetyononesideofthe X26P CEW while attempting to move it ontheotherside.ThiscanbreakthesafetyanddisabletheCEW.

• Withdefaultsettings,iftheX26PCEW’ssafetyswitchisleftintheup(ARMED)positionformorethan20minutes,thesystemgoesintolowpowermodetoreducetheamountofpowerconsumed,andtheCEWwillnotfire.AlthoughtheCEWwillnotfire,powerisstillconsumedandwilleventually

LASER

Low Intensity Lights

(LEDs)

Cartridge Release Tab

Performance Power Magazine (PPM)

Textured Grip Zones

Illumination SelectorSafety Switch

PPM Release Button

Trigger

AFIDs

Wire

Mechanical Sights

TASER Cartridge

Smart Probe

Blast Door

Chapter 3: Features

Up (ARMED)Down (SAFE)

Page 11: TASER X26P CEW User Manual

7

TASER X26P CEW User Manual

Chapter 3: Features

drainthebatteryifthesafetyswitchremainsintheARMEDposition.Tore-armtheCEW,shiftthesafetytothedown(SAFE)position,andthenshiftitbacktotheup(ARMED)position.

LASERTheLASERinstalledintheX26PCEWisorientedwiththemechanicalsights.At15feet(4.6m),theaimingpointisalignedtotheapproximatetrajectoryofacartridge’stopprobe.

Mechanical Sights The mechanical sights on the X26P CEW are molded to provide manual aiming of the CEW. The mechanicalsightsaresettocoincidewithatopprobe’strajectoryata15-foot(4.6m)distance.

Performance Power Magazine (PPM) Battery PackThePerformancePowerMagazineisalithiumenergycellpowersupplysystemfortheX26PCEW.

Note:X26PbatterypackswillnotworkwiththeTASER7,X3,orX26CEWs.BatterypacksdesignedfortheX2CEWwillworkintheX26PCEW.

Batterypacksshouldbestoredintheiroriginalpackaging,includingthedesiccantbag,untiltheyaretobeused.DonotstorethePPManywherethatthegoldcontactsonthetopofthePPMmaytouchmetalobjects.Ifyoucauseanelectricalshortbetweenthesecontacts,theshortwilldrainthebatteryandmaycausethepackitselftobecomedangerouslyhot.

The PPM battery has enough power for approximately 500 five-second discharges depending ontemperature,environment,useoftheflashlight,andotherfactors.ThePPMbatterywilldepletefasterin colderweather thanwarmweather. Likewise, thebatterywill deplete fasterwith theflashlightactive.

For more information on installing the PPM, see Changing the Battery Pack.

Note:Other battery pack options are available for the X26PCEW. See Tactical Performance Power Magazine (TPPM) Battery Pack, eXtended Performance Power Magazine (XPPM) Battery Pack, Automatic Shut-Down Performance Power Magazine (APPM) Battery Pack, eXtended Automatic Shut-Down Performance Power Magazine (XAPPM) Battery Pack, and Signal Performance Power Magazine (SPPM) Battery Pack (Model T00074).

Rear Mechanical SightFront Mechanical Sight

Page 12: TASER X26P CEW User Manual

8

TASER X26P CEW User Manual

Chapter 3: Features

Changing the Battery PackTochangethebatterypack:

1 Point the CEW in a safe direction.

2 Ensurethesafetyswitchisinthedown(SAFE)position.

3 SafelyremovetheTASERcartridge(donotplaceanybodypartsinfrontofthecartridge).SeeUnloading (Chapter4) for more information.

4 Tounloadthebatterypack,depressthebatterypackreleasebuttonandremovethebatterypackfromthehandleoftheCEW.

5 Inspectthebatterycontacts.EnsurethattheyareappearinworkingorderandarefreefromdirtorotherresiduethatmayinterruptthebatteryconnectiontotheCEW.

6 InstallthenewbatterypackandensurethatitisfullyinsertedintheX26PCEW.Applysufficientforce to ensure the battery pack is fully seated.When thebattery pack seats properly, thereleasebuttonshouldpopoutfromtherecessedportionwithanaudibleclick.

Tactical Performance Power Magazine (TPPM) Battery PackThe optional TPPM has an extension to provide a larger grip on the CEW. The TPPM does not hold an extra cartridge.

Release Button

Page 13: TASER X26P CEW User Manual

9

TASER X26P CEW User Manual

Chapter 3: Features

eXtended Performance Power Magazine (XPPM) Battery Pack

To install a TASER standard cartridge in an XPPM:

1 Ensure the cartridge cover is removed. See Removing the Shipping Cover from the Cartridge (Chapter4).

2 Keepingyourhandawayfromtheblastdoors,depressthetabsonthesidesofthecartridge.

3 Insert the cartridge in the XPPM so the blast doors face forward, toward the front of the CEW.

Toremovethecartridge,keepingyourhandawayfromtheblastdoors,depressthetabsagainandpull the cartridge out of the XPPM.

Automatic Shut-Down Performance Power Magazine (APPM) Battery PackTheoptionalAPPMisamodifiedbatterypackthatshutsdowntheoutputoftheX26PCEWafterfivesecondsandalsocontainsabuilt-inspeakerthatalertsyoutotheimpendingshutdown.TheAPPMiconwillbedisplayedinthetopleftcorneroftheCIDwhentheCEWdetectsthatanAPPMisinstalled.

Under stressful situations, audio exclusion might prevent you from hearing the alert from the APPM.

TheAPPMprovidesanaudiblebeepingalertforthelasttwosecondsofatrigger-initiatedcyclebeforeautomaticallyshuttingdownthecycle.Aftera5-seconddeploymentduration,theenergyburstwillstopevenifyourfinger isstillpullingthetriggerswitch.Theaudiblebeepingalertwillcontinuetosounduntilthetriggerswitchisreleased.Tore-energizethedeployedcartridge,firstensurethatyourfingerisoffthetriggerswitch,andthenpressthetriggeragain.

ReplacingtheAPPMwithaDifferentBatteryPackYourCEWwill recognizetheAPPMasauniquetypeofbatterypack. IfyouremovetheAPPMandreplaceitwithadifferenttypeofbatterypack,theX26PCEWwillreturntoitsnormalconfiguration.Thatis,therewillnolongerbeanaudioalert,andtheenergycyclewillcontinueafterfivesecondsifyourfingerisstillholdingdownthetriggerswitch.AlwaysconfirmthattheCEWperformsasexpectedbeforereturningittodutyafterchanginganybatterypack.

Remove the cartridge before testing the CEW function. See Unloading (Chapter 4) for more information.

Page 14: TASER X26P CEW User Manual

10

TASER X26P CEW User Manual

Chapter 3: Features

eXtended Automatic Shut-Down Performance Power Magazine (XAPPM) Battery PackTheXAPPMholdsanextraTASERstandardcartridgeliketheXPPMandenablestheautomaticoutputshut-down functionality of the CEW like the APPM. See Automatic Shut-Down Performance Power Magazine (APPM) Battery Pack for more information.

Signal Performance Power Magazine (SPPM) Battery Pack (Model T00074)

The optional Signal Performance Power Magazine (SPPM) is a battery packdesignedtoworkwithdevicesthatareequippedwithAxonSignaltechnology.

WhenanX26PCEWisequippedwithanSPPM,shiftingtheCEW’ssafetyswitchtotheup(ARMED)positioncausestheSPPMtosendasignal.Uponreceiptofthissignal, a compatible device can perform a programmed response.

Note:Your CEWmust have firmware version 4.032 or greater tomake use oftheSPPM’sspecialfeatures.Withoutthefirmwareupdate,theSPPMonlyfunctionsasabatterypacklikethePPM.EvidenceSyncversion3.15.30orgreaterisrequiredtoconfiguretheSPPM.SeetheEvidence Sync User Manualformoreinformationonfirmwareupdates.

TheSPPMtransmissionbeginsafterthesafetyswitchisshiftedtotheup(ARMED)position.Thesignalhasarangeofupto30feet(9.1meters)line-of-sight.

TheSPPMiconwillbedisplayedinthetopleftcorneroftheCIDwhentheSPPMhasstartedtransmittingtheCEWstatus(seethetablebelow).

ThesearethetypesofinformationtheSPPMtransmissionsends:

Event DescriptionARMED event Thesafetyswitchwasshiftedtotheup(ARMED)position.ARMED + 10 seconds Tensecondshaveelapsedsincethesafetyswitchwasshiftedtotheup

(ARMED)position.Trigger event The trigger was pressed.Signal Mute Mode SignalMuteModehasbeenactivatedbytheuser.

Automatic Shut-Down OptionThe SPPM can enable the automatic shut-down feature when used in a CEW. The X26P will function thesamewayasifitwereequippedwiththeAPPMbatterypack.SeeAutomatic Shut-Down Performance Power Magazine (APPM) Battery Pack for more information. To enable the automatic shut-down feature, theagencymustconfiguretheCEWthroughAxonEvidenceservices.

SPPM Transmit in Safe OptionTheX26PCEWcanbeconfiguredtoremainpoweredafterthesafetyswitchisshiftedtothedown(SAFE)position,whichallowstheSPPMtofinishthetransmissionofanypendingstatusforthefull30seconds.TheCIDwillcontinuetodisplaytheSPPMiconanddisplayamessage“DONOTREMOVEBATTERY.”Ifthesafetyswitchisshiftedtotheup(ARMED)positionwhilethedeviceisstillsendingaSignal transmission, the 30-second timers for each status event will be restarted. Do not remove the SPPMfromtheCEWuntilthedevicehasfinisheditsSignaltransmissionandtheCIDgoesblank.To

Page 15: TASER X26P CEW User Manual

11

TASER X26P CEW User Manual

Chapter 3: Features

enabletheTransmitinSafefeature,theagencymustconfiguretheCEWthroughtheAxonEvidencewebsite.Enablingthissettingwilldecreaseexpectedbatterylifetimefirings.

Signal Mute ModeIfyourCEWisequippedwithanSPPMbatteryback,SignalMuteModecanbeenabledtoNOTalertAxoncamerastorecord.Thismaybeusefulwhenperformingafunctiontest.SeeFunction Test (Chapter5)formoreinformation.MuteModeisenabledbytheuserwhentheCEWisinconfigurationmode;see Enabling SPPM Signal Mute Mode.Thedevicewillreturntonormaloperationafterthesafetyswitchisplacedinthedown(SAFE)position.Anypending30-secondtransmissionswillbediscontinued.

Updating the SPPM FirmwareToupdatetheSPPMfirmware,thedevicemustbeconnectedtoaTASERcentraldeviceovertheair(OTA).TheCEWsendsacommandtotheSPPMtostartatransmissionforthisconnectionwhentheCEWisinconfigurationmode.Withthesafetyswitchinthedown(SAFE)position,presstheselectorswitch on the top of the X26P CEW. After a connection with a central device has been established, the CIDwillchangetodisplaytheSPPMbatteryiconandamessage“DONOTREMOVEBATTERY.”Oncethe connection to the central device has ended, the CEW will return to the standard selector mode menuortheCEWwillexitconfigurationmode.

Advanced Central Information Display (CID)TheAdvancedCIDisamonochromeorganiclightemittingdisplayonthebackoftheX26PCEW.Whenthesafetyswitchisshiftedintotheup(ARMED)position,theCIDwilldisplaythebatterystatus.

Energy Cell Indicator:61-80% Remaining

System Status IconsThe system status icons are designed to inform you of the system status of the X26P CEW. It is a fault indicator only, and it is the user’s responsibility to conduct proper maintenance, and ensure that the CEW is working properly before any use. Failure to heed the system status icons could cause serious injury or death.

Major fault indication. Ayellowtriangle indicates that the logging,dateand time functions,orability for theCEW to successfully read thePPMinformation are not working properly. The CEW will still produce anelectricaloutput(e.g.,theCEWshouldstillarcanddeploycartridges),buttheaccountabilityfunctionsarecompromised.

Shift the safety switch to the down (SAFE) position and then to the up(ARMED)position;thefaultmayclear.

Whether the fault clears or not, it will be recorded in the Engineering log. Ifthefaultdoesnotclear,doNOTattempttousetheCEW.TheCEWmayneed to be repaired or replaced. See Product Returns (Chapter 5) for instructions

Page 16: TASER X26P CEW User Manual

12

TASER X26P CEW User Manual

Chapter 3: Features

Critical fault indication.Ayellowstopsignintheupper-rightsideoftheCIDindicatesasystemfailure.

Critical faults are rare.DoNOTattempt touse theCEW. TheCEWmayneed to be repaired or replaced. See Product Returns (Chapter 5) for instructions.

Invalid battery pack.Ifyouseeablinkingexclamationpointandbatteryicon,this indicatesthattheCEWdidnotrecognizethebatterycorrectly.Remove thebatterypackand reinsert it. If theerror is still present, tryanotherbatterypack.Iftheiconstilldisplays,theCEWshouldbesentinfor service if it is still under warranty. See Product Returns (Chapter 5) for instructions.

AnAPPMorXAPPMbatterypackisinstalledintheCEW.

A TASER CAM HD recorder is installed in the CEW. See TASER CAM HD Recorder Operating Manual for more information.

A TASER CAM HD recorder with the automatic shut-down feature is installed intheCEW.Thisrecorderoffersanaudiowarningandshut-downfeaturelikethatofanAPPMbatterypack.SeeTASER CAM HD Recorder Operating Manual for more information.

AnSPPMbatterypackisinstalledintheCEW.SeeSignal Performance Power Magazine (SPPM) Battery Pack (Model T00074) for more information.

AnSPPMbatterypackisinstalledintheCEW,andtheCEWisinMuteMode.See Enabling SPPM Signal Mute Mode for more information.

X21234567

When you plug the USB download cable into the X2 CEW, the USBconnection status icon and the device serial number will appear. See USB Connection Status (Chapter5) for more information.

DO NOT REMOVEBATTERY

When there is an SPPM transmission in the safe mode or the SPPM is connecting for updates, the warning DO NOT REMOVE BATTERY isdisplayed.

Battery Level IconsWhenthesafetyswitch is in theup (ARMED)position, theCIDwilldisplay thepercentageofbatterypowerremaining.Remainingcapacitywilldisplayin20percentincrements.

When thebattery leveldropsbelow20percent,Axonrecommends that thebatterypackbereplaced.

Page 17: TASER X26P CEW User Manual

13

TASER X26P CEW User Manual

Chapter 3: Features

Battery Battery Battery Battery81–100% 61–80% 41–60% 21–40%

Ifthebatterycapacityisat1–10percent,theCIDwillflashthewarning LO BATT ontheCIDwhenthesafetyswitchiscycledtotheup(ARMED)positionwhenusinganyPPMtype.

The LO BATT warning will be displayed when the batterycapacityisbetween1–40percentforTASERCAMHD.

Battery01–20%Blinking

Ifthebatterycapacityisat1–20percent,thisicondisplaysinthe lower-right portion the CID.

WhentheTASERCAMHDbatteryisdepleted,theCIDwillflashthe warning RECHARGE BATTERYontheCIDwhenthesafetyswitchiscycledtotheup(ARMED)position.

WhenusinganyPPM-typebatterypack that isdepleted, theCIDwillflashthewarningCHANGE BATTERY on the CID when thesafetyswitchiscycledtotheup(ARMED)position.

Spark DurationTheCIDdisplaysacountindicatinghowmanysecondsthedeploymentcyclelasts.TheCEWwillcountup from the number 1 up to 99. At 99 seconds, the count will restart at 1.

Sample CID DisplaysTheCIDbelowshowstheX26PCEWwithaTASERCAMHDrecorderinstalledandabatterycapacityof 61–80 percent.

TASER CAM HD Recorder

Battery:61-80% Remaining

TheCIDbelowshowsaCEWthathasbeendischargingforfourseconds,withabatterypackthatisat41–60percentcapacity.

Battery:41- 60% Remaining

Count

TheCIDbelowshowsaCEWwithanAPPMbatterypackinstalledthathasabatterycapacityof61–80

Page 18: TASER X26P CEW User Manual

14

TASER X26P CEW User Manual

Chapter 3: Features

percent.

APPM Installed

Battery:61-80% Remaining

TheCIDbelowshowsaCEWwithabatterypackerror.

InvalidBattery Pack

TheCIDbelowshowsaCEWthatis4secondsintoanenergyburst,hasabatterypackthatis81–100percent charged, and a major fault with the CEW.

Battery:81- 100% Remaining

CountMajor Fault

LED FlashlightTheX26PCEWhasahighintensitywhiteLEDtoaidtheuserindarkenvironments.

Selector Switch (LASER and LED Flashlights)You can select four modes of illumination when using the X26P CEW. To change the illumination setting:

1 Point the CEW in a safe direction.

2 Ensurethesafetyswitchisinthedown(SAFE)position.

3 Keepingyourhandawayfromtheblastdoors,depressthetabsonthesidesofthecartridgeand remove.

4 PressandholdtheselectorswitchforapproximatelyoneseconduntiltheCIDdisplayilluminates.

Page 19: TASER X26P CEW User Manual

15

TASER X26P CEW User Manual

Chapter 3: Features

Note:Usingpensorpaper clips topress theselector switchmaydamage it.Onlyuseyourfingertopresstheselectorswitch.

5 Press and release the selector switch to toggle through the four available settings on the CID. Stopwhenthesettingyoudesireishighlighted.

OO: Neither the LASER nor the Flashlight will illuminate.

LO:OnlyLASERwillilluminate

OF:OnlyFlashlightwillilluminate

LF: LASER and Flashlight both illuminate

Theselectedmodedisplaysfor30seconds,andwillbethedefaultmodethenexttimethesafetyswitchismovedtotheup(ARMED)position.

TheselectorswitchmayalsobeusedtoactivatetheStealthMode,whichwillshutofftheLASERandflashlight,anddimtheCIDdisplay.Todothis,presstheselectorswitchwhenthesafetyisintheup(ARMED)position.TotaketheCEWoutofStealthMode,presstheselectorswitchagainorshiftthesafetytothedown(SAFE)position.YouwillhavetoreactivatetheStealthmodeeachtimeyouplacethesafetyintheup(ARMED)position.

Enabling SPPM Signal Mute ModeIfyourCEWisequippedwithanSPPMbatteryback,SignalMuteModecanbeenabledtoNOTalertAxon cameras to record. Thismay be useful when performing a function test. See Function Test (Chapter5) for more information.

1 With the safety in the down (SAFE) position, press and hold the selector switch until theilluminationmenudisplays.

2 Press and release the selector switch until the LF setting is highlighted.

3 Pressandreleasetheselectorswitchand“SPPMMUTE”willbedisplayedontheCID.

4 If the safety switch is placed in theup (ARMED)positionwhile this screen is displayed, theCEW will enter Mute Mode for the session. In Signal Mute Mode, an inverted SPPM icon will be displayedintheupperleftcornerofCID.SeeSignal Mute Mode for more information. The device willreturntonormaloperationafterthesafetyswitchisplacedinthedown(SAFE)position.

SPPM MUTE

Page 20: TASER X26P CEW User Manual

16

TASER X26P CEW User Manual

Chapter 3: Features

Anypending30secondtransmissionswillbediscontinued.SeeSPPM Transmit in Safe Option for more information.

Trigger SwitchUnlikeafirearmtrigger,theX26PCEWtriggerisamomentaryelectricalswitch.Theswitchisoperationalonlywhenthesafetyswitchisintheup(ARMED)position.Pullingandreleasingthetriggerswitchwillresultinanapproximately5-seconddischargecycleunlessthesafetyswitchisshiftedtothedown(SAFE)positiontodiscontinuethe5-secondcycle.Pullingandholdingthetriggerswitchformorethanfivesecondswillresultinacontinuousdischargeuntilthetriggerswitchisreleased,orthebatteryisdepleted—whichevercomesfirst.

AnX26PCEWequippedwiththeAPPMbatterypackislimitedto5-seconddischargesandemitsanaudio alert two secondsbefore the endof the cycle. SeeAutomatic Shut-Down Performance Power Magazine (APPM) Battery Pack for more information. An X26P CEW equipped with an SPPM can be configuredtoenabletheCEW’sautomaticshutdownfeature.SeeSignal Performance Power Magazine (SPPM) Battery Pack (Model T00074) for more information.

In the event of an accidental discharge, immediately move the safety switch to the down (SAFE) position to stop the discharge cycle.

Trigger Switch

Page 21: TASER X26P CEW User Manual

17

Chapter 4: Cartridges & CEW operation

Removing the Shipping Cover from the Cartridge

CartridgesaresoldseparatelyfromtheCEW.Cartridgesareshippedwithashippingcoverinplace.CarefullyremovethesecoversbeforeattemptingtoloadacartridgeintotheX26PCEW.Becarefultonotallowanybodyparttobeinfrontofthecartridge.Staticelectricitycandischargeacartridge,andinjuries have occurred. A cartridge cannot be loaded into the CEW with the cover in place. Once the cartridge cover is removed, it can be disposed of.

1 Beforeremovingthecovers,makesurethefrontofthecartridgedoesnotpointatanybodypartoratanyone.

2 Carefullyplacethecartridgewithcoverfacedown(blastdoordown)ontoastable/solidsurface,i.e., a table.

3 Placeyourindexandmiddlefingersontothesidesofthecartridgewherethewedges/electrodesarelocatedandplaceyourthumbsontothelockingportionsofthecover.

4 Pushinwithyourfingersandpulloutwardwithyourthumbsandthecartridgewillpopupward,releasing it from the cover.

Note:Thecartridgemaypopupwardquicklywhenthepressureisreleasedfromthelockingportions of the cover.

15, 21, LS, and XP25 TASER CartridgesNever attempt to open or modify a TASER cartridge. Tampering with a live TASER cartridge could causeittofireormalfunction(whichmayresultinseriousinjury).

Handle all TASER cartridges with care. Probes may deploy unexpectedly if exposed to physical shock, or static electricity.

TASERcartridgesshouldbekeptawayfromconditionsknowntocreateanelectrostaticdischarge,suchasrubbingcloth(e.g.,jacketlineroruniformpants)acrossacartridgeinanenvironmentknowntocreatestaticshocks.

Page 22: TASER X26P CEW User Manual

18

TASER X26P CEW User Manual

Chapter 4: Cartridges & CEW operation

Cartridgeblastdoorscanbeknockedoffthefrontofacartridge.Becausethosecartridgescannotbereliedupontoconsistentlydischarge,TASERrecommendsremovingthosecartridgesfromservice.Attemptingtodeployacartridgewithnoblastdoorscouldresultinachargebeingcreatedandheldinthewires.Anyconductivematerialthatcomesintocontactwiththefrontofthecartridge,evenafterthecyclehasended,coulddrawthechargetotheignitionpinanddeploytheprobes.

TASERoffersaBlastDoorRepairKitthatcanbeusedtoreplaceblastdoorsthatcomeoff.Cartridgeswithreplacedblastdoorsshouldonlybeusedfortrainingandshouldnotbedeployedtothefield.Gotowww.axon.comformoreinformationontheBlastDoorRepairKit.

AFIDEvery time a TASER cartridge is deployed, approximately 20–30 small confetti-like Anti-FelonIdentification (AFID) tags are ejected. Cartridges can be assigned to individual users, as each isserialized.EachAFIDtagisprintedwiththecorrespondingserialnumberofthecartridgedeployed,allowingdeterminationofwhichuserdeployedtheparticularcartridge.

Load the TASER CartridgeNever place your hands or fingers in front of the cartridge. This is especially importantwhenloading and unloading the cartridge. Serious injury could result. When loading and unloading always hold the cartridge on the sides or top.

TASER cartridges are shipped with a shipping cover in place. Remove these covers before attempting to load a cartridge into an X26P CEW. See Removing the Shipping Cover from the Cartridge for more information.

Loading1 Point the CEW in a safe direction.

2 Ensurethatthesafetyswitchisinthedown(SAFE)position.

Loaded Unloaded

Page 23: TASER X26P CEW User Manual

19

TASER X26P CEW User Manual

Chapter 4: Cartridges & CEW operation

3 MakesuretheprotectiveshippingcoverisremovedfromtheTASERcartridge.

4 Keepingyourhandaway fromtheblastdoors,place thecartridge (with thecartridgecoverremoved)intothefrontoftheCEWuntilanaudibleclickisheard.

5 Verifythatthecartridgeissecurebypullingonthesidesofthecartridge.

Unloading1 Point the CEW in a safe direction.

2 Ensurethatthesafetyswitchisinthedown(SAFE)position.

3 Keepingyourhandawayfromtheblastdoors,depressthetabsonthesidesofthecartridgeand remove.

The 15-, 21-, and 25-foot (4.6-, 6.4-, and 7.6-meter, respectively) TASER cartridges are specificallydesignedsothere isno“up”or“down”position–enablingyoutoquicklyreloadoneinastressfulsituationwithoutworryingaboutputtingitinupsidedown.

Aiming and Probe Placement

Formost deployments, hold the CEW level.Tilt the CEW when necessary to align theprobes with the target.

All TASER CEW deployments should be inaccordance with current TASER training and warnings, and department training, policies, and procedures.

When practicable, aim the LASER at the preferredtargetareasofthebody,whicharethelowercenter-mass(belowthechest)andlegs when the subject is facing you, or thesubject’s back if the subject is turned awayfromyou.

When possible, avoid intentionally targeting the CEW on sensitive areas of the body such as the head, throat, chest/breast, or known pre-existing injury areas without legal justification.

The top probe impacts the target near the LASER beam; however, the probe impactdistancefromtheLASERwillvarydependingon the distance between the CEW and the

Level Tilted

Page 24: TASER X26P CEW User Manual

20

TASER X26P CEW User Manual

Chapter 4: Cartridges & CEW operation

target,typeofcartridge,etc.At15feet(4.6m),theLASER’spositioncorrespondstothetrajectoryofa25-foot(7.6m)cartridge’stopprobeatthesamerange.

The bottom probe impacts at an 8-degree angle from the top probe. This results in a spread of approximately1foot(0.3m)forevery7feet(2.1m)ofdistancefromtheCEW.Greaterprobespreadincreaseseffectiveness.

“Silence is Golden”TheTASERCEW’selectricalcurrentisrelativelyquietwhenbothprobesmakedirectcontactwithahumanorananimal. Incontrast,somepracticeconductivetargetsare loudbecausetheenergy isarcing in the air.

Ifelectricalcurrentisloudduringfielddeploymentandthesubjectisnotreactingasexpected,theelectricalcircuitmaynotbecompletedorthecurrentmaybeshortingoutandmaynotbeeffective.Deployasecondcartridgeorconsiderotheroptionsinaccordancewithyouragency’spolicies.

Audible Pulse Rate ChangesTheCEWnormallyarcsatanaveragerateof19pulsespersecond(PPS).ToimprovetheservicelifeoftheCEWandbatterylife,firmwareversion4.029allowsthePPSratetodroptoapproximately9PPSwhenthereisnoconnection(e.g.,asingleprobehit,clothingdisconnect,etc.).Thus,firingprobesintoanon-conductive targetwill likelycause thisPPSreduction tooccur.Upondetectingaclosedcircuit,thePPSwillimmediatelyreturnto19PPS.ThischangeinPPSdoesnotaffectdailyfunctionalitychecks,drive-stuns,oreffectiveprobedeployments.

PotentialCausesofReducedorNoEffectiveness• Loose or Thick Clothing.Iftheprobeslodgeinclothingandaretoofarawayfromthesubject,CEW

effectivenessmaybereduced.

• Miss or Single Probe Hit. The electrical current must pass between the probes. If one probe misses, theCEWwillnotbeeffective.

• Low Nerve or Muscle Mass.Iftheprobesimpactinanareawherethereisverylittlemusclemass(e.g.,thesideoftheribcage),theeffectivenessmaybereduced.

• Limited Probe Spread.Probespreadsoflessthan12inches(30cm)mayresultinreducedCEWeffectiveness.

• Wires Break.Ifawirebreaks(e.g.,duringastruggle),thecurrentwillnotflowtotheprobesandtheCEWwillnotbeeffective.

Inanyoftheabovescenarios,asecondcartridgemaybedeployedoradrive-stunfollowupmaybeusedifpractical,justified,andwithinyouragency’spolicy.

Page 25: TASER X26P CEW User Manual

21

TASER X26P CEW User Manual

Chapter 4: Cartridges & CEW operation

Do not become over-dependent on the TASER CEW. No force option, including CEWs, is 100% effective in every situation. Do not deploy the CEW without following your department policies and procedures.

ElectrodesThe front of the X26P CEW has two metal electrodes. These electrodes direct the charge to the electrodesonthecartridgetoinitiatedeploymentoftheprobes.Inaddition,theelectrodesprovidetheabilitytousetheX26PCEWina“drive-stun”modeasatraditionalstun-guntypeCEW.

Drive-Stun Backup Drive-stuncapability isavailablewithorwithoutaTASERcartridge installed.Toapplyadrive-stun,placethesafetyintheup(ARMED)positionandpullthetrigger.

Whenusingthedrive-stun,push(drive)thefrontoftheCEWfirmlyagainstthebodyofthesubject.Simply“touching”theCEWagainstthesubjectisnotsufficient.ThesubjectislikelytorecoilandtrytogetawayfromtheCEW.ItisnecessarytoaggressivelydrivethefrontoftheCEWintothesubjectformaximumeffect.

Drive-stunmodeisnotdesignedtocauseincapacitationandprimarilybecomesapaincomplianceoption.Drive-stunisonlyeffectivewhiletheCEWisincontactwiththesubjectorwhenpushedagainstthesubject’sclothing.AssoonastheCEWismovedaway,theenergybeingdeliveredtothesubjectstops.

Iftheprobesaredeployed,evenatverycloserange,theusermaydrive-stuntoanotherportionofthebodythatisfurtherawayfromtheprobes,therebyincreasingthepossibilityofinducingincapacitation.

Electrode

Electrode

Page 26: TASER X26P CEW User Manual

22

TASER X26P CEW User Manual

Chapter 4: Cartridges & CEW operation

RecommendedDrive-StunAreasforMaximumEffectUsetheCEWpursuanttoyouragency’spoliciesandprocedures.Formaximumeffectiveness,drivethe X26P CEW into the highlighted green areas as outlined below.

Suggested pressure points are highlighted in the green areas. Use care when applyingthedrive-stuntotheneckorgroin(yellowareas–usersshouldonlytarget theseareaswhen theyaredefending themselves against a violentattacker).Stayawayfromthetracheaandbackoftheneck.Thetracheaissofttissueandcouldeasilybecrushed.Thecervicalportionofthespineisverysensitivetopressure.Also,careshouldbetakenwhenapplyingadrive-stuntothepelvictriangletoavoidthepossibilityofcrushingthetesticles.

Refer to your department’s policy regarding drive-stuns in these and other sensitive areas.

Page 27: TASER X26P CEW User Manual

23

Chapter 5: Maintenance/Troubleshooting

Function TestAxonrecommendsconductingafunctiontestevery24hoursorpriortothestartofyourshiftforyourindividuallyissuedX26PCEW.ThefunctiontestisdonetoverifythattheCEW’scoreelectronicsareworkingproperly.

Function Test Instructions 1 Point the CEW in a safe direction.

2 Shiftthesafetyswitchtothedown(SAFE)position.

3 Remove the TASER cartridge. A function test should never be conducted with a TASER cartridge in the CEW.

4 EnsurethatyourfingersandnootherpartofyourbodyareinfrontoftheX26PCEW.

5 Shiftthesafetyswitchtotheup(ARMED)position.

6 Pullthetriggerandvisuallyconfirmsparkingacrosstheelectrodes.Allowthefull5-secondcycleto run.

View the arc from the top or side of the CEW. Do not point the CEW at your face or have it near your face.

7 LookattheCIDdisplayandverifythefollowing:

• NofaulticonsdisplayontheCID.

• LOBATTisnotdisplayingontheCID.

Ifanyoftheaboveverificationsfail,returntheunittoyouragency’sCEWtechnicianforservice.

8 Shiftthesafetyswitchtothedown(SAFE)position.

Page 28: TASER X26P CEW User Manual

24

TASER X26P CEW User Manual

Chapter5:Maintenance/Troubleshooting

What to Do following CEW UseConsiderations for Handling Used Probes

Eachagencywillestablishitsownprocedureforproberemoval,collection,biohazards,evidencecol-lectionandmaintenance.Treatprobesthathavepenetratedthebodyascontaminatedneedles(bio-hazard).Remember,however,thattheprobesmayalsobevaluableevidence.

If the probes must be removed from the subject, follow all department policies and procedures, in-cludingforhandlingbiohazards.

Belowaresuggestedmethodsforproberemoval.

• Grabtheprobefirmlyandquicklypullitstraightout.Donottwisttheprobeasthebarbedtipmaycauseadditionalinjury.

• Iftheprobesarenotgoingtobecollectedandmaintainedforevidence,carefullyplaceusedprobessharp-tipfirstintoasharpscontainer,secureinplace,andplaceinasecurelocationwherenoonewillaccidentallytouchtheprobes.

• Once the subject is restrained, prior to removing the probes, evaluate the need for medical atten-tionasyouwouldwithanyotheruse-of-forceincident.*

• Takephotosofanyinjuries,placethephotosintoevidence.*

• Collecttheexpendedcartridge,probes,andAFIDsandplacethemintoevidence.*

*Asdirectedbydepartmentpolicy.TheTASERtrainingmaterialsprovideadditionalinformationonforensicevidencecollectionprocedures.Theprobes,wires,AFIDs,andcartridgecanyieldimportantforensicevidenceifproperlycollected,maintained,andanalyzed.EnsurethattheCEWisdownloadedandthedownloadedlogsarecollectedperyouragency’spolicy.

EffectsonAnimalsTASERCEWscanbeaneffectiveoptionfordealingwithaggressiveanimalsandhavegenerallybeensuccessfulindeployments.

Note: Ifaprobedeploymentcompletedcircuitisinitiatedandmaintained,theaggressiveanimalsareusuallyincapacitated/stunnedmomentarilyinCEWdeployments,butrecoverquickly.Typically,theanimalsquicklyleftthesceneandbrokethewires.

Ifdeployedonadomesticanimal,considerhavinganimalcontrolavailabletorestraintheanimal.

Police/Military K-9 Caution CEWoperatorsandK-9officersmustworkcloselytogethertodeveloppoliciesandproceduresforde-

Page 29: TASER X26P CEW User Manual

25

TASER X26P CEW User Manual

Chapter5:Maintenance/Troubleshooting

ployingtheCEWwhenaK-9ispresent.IfaK-9bitesaprobeorbitesthesuspectbetweentheprobes,theK-9couldreceiveashock.ThiscouldhaveanegativeimpactonthefuturedutyuseoftheK-9.

Downloading Firmware RevisionsTheX26PCEWinternalfirmwareprovidesfunctionalityforallaspectsoftheCEW.ThefirmwarecanbeupgradedtothemostrecentversionbyusinganX26P/X2CEWDataportDownloadKitandEvidenceSyncsoftware(OnlineorOffline).

Do not remove the USB cable or press the reset button on the Dataport USB pack during the reprogramming cycle.

Dataport Download KitOptionaldownloadkitsareavailabletopermitagenciestoaccessthedeploymentinformationintheX26PCEWmemorythroughtheAxonEvidenceservicesortheSyncOfflineorOnlineClientsoftware.

Note: IfyouhaveaTASERCAMHDrecorder,pleaseseetheTASER CAM HD Recorder Operating Manual and the Evidence Sync User Manual for downloading instructions.

TheX26PCEWusesaUSBadapter(downloadcable)toconnecttoanyWindows7orWindows10com-puter.ThesimplicityofUSBmakesusingthedataportdownloadkitaneasy,fastprocess.ThecableconnectstotheCEWthroughthebatterycompartment.

USB Connection StatusTheUSBiconwillflashontheCIDwhentheCEWissearchingfortheEvidenceSyncclientsoftware.TheiconwilldisplaysolidwhentheCEWisconnectedtothesoftware.

EvidenceSyncOfflineSoftwareIfyoudonothaveanAxonEvidenceaccount,theEvidenceSyncsoftwarecanbeusedintheOfflinemodetodownloadthesimplifiedEvent logtoyour localcomputerandprint it.TheEvidenceSyncOfflinesoftwarewillnotenableyoutoviewthefullTrilogylog.

EvidenceSyncOfflinewillnotallowyouto:

• Enable hard stop

• Disable the SPPM automatic shut-down

• Enable or disable signal transmission in safe

• Enable sharing of the engineering logs with Axon

Trilogy Log UponuploadtoAxonEvidence,thesystemcollectstheinformationintothreerelateddatalogscalledtheTrilogylogs:

Page 30: TASER X26P CEW User Manual

26

TASER X26P CEW User Manual

Chapter5:Maintenance/Troubleshooting

• Event log

• Pulse log

• Engineering log

ThedatasetfromtheTrilogylogisuploadedsecurelytoAxonEvidenceservices,wheretheinforma-tion isencrypted,storedsecurely,andorganized intodashboardsthatallowyouragencytoeasilymonitortheusageandsystemstatusofyourentirearsenalofX26PCEWs.

UponuploadtoAxonEvidenceservices,thesystemdisplaystheinformationfromtheEventandPulselogs.YourtypeofAxonEvidenceaccountwilldeterminewhatdatacanbeviewedfromtheselogs.

Event LogTheEventlogtrackseventsandmayhelpprotectauserfromclaimsofexcessiveuseofforcebypro-vidingdocumentationofthetimeanddateforeachCEWdeployment.TheEventlogalsoprovidesagencieswithapowerfulmanagementtooltotrackusagepatternsandhelppreventmisuse.Youdonot need to download the X26P to Axon Evidence services to obtain the Event log – this can be down-loadeddirectlytoyourPCusingtheEvidenceSync(Offline)software.

TheEventlogincludesthefollowinginformationforthemostrecent(approximately)16,000entries:

• Eachentrycontainsthedateandtimeofeachevent.

• Entries includeArmed,Safe,Trigger,USBconnection,PowerSavemode,firmwareupdates, timesynchronizations,PPMchanges,SPPMEndoftransmission,agencysettingchanges,etc.

• The duration of each Trigger event.

• ThedurationofeachSafeevent(howlongtheCEWwasarmedwhenthesafetyswitchwasmovedtothedown[SAFE]position).

• The internal temperature is shown for Armed and Safe events.

• Batterypercentageisshownforallarmedsessionevents(Armed,Trigger,Safe).

Whenthelogfillstoapproximately16,000entries,itwilldeletetheoldest4,096recordsandwritenewones. This process will continue in 4,096-record increments.

Pulse LogThePulselogrecordsanypulseactivity.TherecordsincludehowlongtheCEWwasdischarged,andthechargeofeverypulse.

Engineering LogTheEngineeringlogmonitorstheperformanceofkeysub-systemswithintheX26PCEW.Itprovidesalertsifasubsystemisnotperformingproperlyandifmaintenanceisadvisable.Anyinternalcircuitryerrors that occur inside the X26P CEW are written to this log. This information is used for diagnostics.

Page 31: TASER X26P CEW User Manual

27

TASER X26P CEW User Manual

Chapter5:Maintenance/Troubleshooting

Time Synchronization TheCEWhasareal-timeclockpoweredbythebatterypackandaninternalbatteryaswell.TheCEWshouldkeepaccuratetimeevenwhenthebatterypackisremoved.

Every time theX26PCEW is connected toAxonEvidence services, the systemwillperforma timesynchronization.Theconversiontolocaltime,includingadjustmentstodaylightsavingstime,areallcomputedbyEvidenceSyncsoftware.ThereisnoneedtoprogramtheX26PCEWtolocaltimeortoreprogramtheCEWtodaylightsavingstime.

IfyoudonothaveanAxonEvidenceaccount,theCEWwillsynchronizewithyourlocalcomputer’stime.

Note: InEvidenceSyncOfflinemode, ifyourcomputer time is incorrect, the incorrect timewillbedisplayedinyourEvidenceSync-generatedreport.

X26P CEW Maintenance and CareEachagencyshouldestablishamaintenanceandhandlingprogram.

The X26P product is a sensitive piece of electronic equipment, and should be handled with care. Avoid dropping an X26P CEW. Do not use an X26P CEW that has a cracked handle.

• Checkthebatterypackregularly.Replaceitwhenthebatterypercentagereaches20%.

• OccasionallywipeouttheX26Pcartridgedeploymentbaywithadrycloth.Multiplecartridgefiringscreatecarbonbuild-up(particularlyaftertrainingcourses)thatshouldberemoved.

Do not wipe out the X26P cartridge bay immediately after the CEW has been fired as you might receive a latent short electrical shock. Wait at least five minutes after the last dis-charge of the X26P CEW before wiping out the bay.

• Secure the X26P CEW in a protective holster when the CEW is not in use.

• Function test the CEW before each shift.

• UpdatetheCEW’sfirmwarewhenupdatedfirmwareisreleased.

• DownloadyourX26PCEWdatatoAxonEvidenceservicesoryourlocalPCatleastonceperquarterandalwaysbeforesendingtheCEWforrepairorwarrantywork.

• Avoid immersing the X26P CEW in water or exposing the X26P CEW to excessive moisture or water.

• See the troubleshooting guide at www.axon.com for additional maintenance instructions.

CheckexpirationofTASERcartridges(5-yearexpirationdateislistedonthebaseofthecartridge).DonotuseanexpiredTASERcartridgeinthefield.Theyshouldonlybeusedfortraining.

Dropped or Wet X26P CEWDo not immerse the CEW in water.

Follow these steps for a CEW that has been completely submerged in water or exposed to a significant amount of water for an extended period of time.

1 SecuretheCEWinaholsterandremovethebatterypackassoonaspossible.

2 Ensurethatthesafetyswitchisinthedown(SAFE)position.

3 Remove the CEW from the holster.

Page 32: TASER X26P CEW User Manual

28

TASER X26P CEW User Manual

Chapter5:Maintenance/Troubleshooting

4 Remove the cartridge. See Unloading (Chapter 4) for more information on removing the cartridge.

5 FollowtheRMAprocesstosubmittheCEW,cartridge(s),andbatterypacktoAxonEnterprise.

Follow these steps for a CEW exposed to some moisture but not submerged in water.

1 PointtheCEWinasafedirectionandawayfromyourbody.

2 Shiftthesafetyswitchtothedown(SAFE)position.

3 Safelyremovethebatterypack.

4 SafelyremovetheTASERcartridge.

5 LettheCEWdryout.

Dry the X26P CEW thoroughly (at least 24 hours). Do not use an external heat source such as a microwave oven or hair dryer to dry the X26P CEW.

6 PointtheCEWinasafedirectionandawayfromyourbodyandensurethatthesafetyswitchisinthedown(SAFE)position.

7 Safelyreinstallthebatterypack.

8 Waitoneminutebeforeproceedingtothenextstep.ConfirmthattheCEWorbatterypackisnot getting warm.

9 Shiftthesafetytotheup(ARMED)position.

• IftheCEWdischargeswithoutthetriggerbeingpressed,shiftthesafetyswitchtothedown(SAFE)positionimmediately,removethebatterypack,returntheCEWtoAxonEnterpriseperthereturnpoliciesiftheCEWisstillunderwarranty.

• If the CEW does not discharge, go to step 10.

10 LookattheCIDtoensuretheX26PCEWisfunctioningproperlyandtheCIDisnotshowinganyfault icons.

11 ConfirmthattheLASERandflashlightareworkingproperly.

12 Press the trigger switch to test the functioning. Conduct three complete 5-second discharges to confirmtheproperpulserateandobservethatthecyclestopsatfiveseconds.Seetheinstruc-tions under Function Test for more information.

13 Ifthetriggerswitchdoesnotwork,oriftheCIDshowsacriticalerroricon,shiftthesafetyswitchtothedown(SAFE)positionimmediately,removethebatterypack,andreturntheCEWtoAxonEnterpriseperthereturnpoliciesiftheCEWisstillunderwarranty.

14 IftheCEWdoesfunctionnormally,shiftthesafetyswitchtothedown(SAFE)position.

15 ConnecttheCEWtoEvidenceSyncandconfirmtheinternaltimeiscorrect.SeetheEvidence Sync User Manual for more information.

16 Confirmthatthethreetriggerdischargeswererecordedproperlyinthedownloadrecords.

17 Return the CEW to service.

Page 33: TASER X26P CEW User Manual

29

TASER X26P CEW User Manual

Chapter5:Maintenance/Troubleshooting

Online Troubleshooting GuideAtroubleshootingguideisavailablebyvisitingwww.axon.com.Ifyouneedproductsupportonacces-soriesorhaveanyotherquestions,pleasecontactAxonEnterpriseTechnicalSupportonlineatwww.axon.com or at:

U.S.: 1-800-978-2737

Australia: 1800512069

Visitwww.axon.com/supportforotherinternationaltelephonenumbers.

Product ReturnsToreturnaTASERproductforservice,firstfollowtheproceduresatwww.axon.com.

Always perform a complete download from the CEW before returning it for warranty or repair work. Any data information will be lost during servicing work performed by Axon.

If the TASER CEW has been exposed to bodily fluids or other biohazards, please contact the cus-tomer service department at U.S.: 1-800-978-2737, Australia: 1800512069 (other international numbers can be found at www.axon.com/support) for specific instructions BEFORE returning the X26P CEW.

Page 34: TASER X26P CEW User Manual

30

Chapter 6: Optional Accessories

Axon Evidence ServicesYoucanuploadthedatafromyourX26PCEWtoAxonEvidenceorEvidence.comLiteservices.Evi-dence.comLiteisafreeversionofAxonEvidence(Evidence.com)servicesandallowsdownloadingtheX26P CEW, viewing the Event and Pulse logs, and updating the CEW software.

ThefullAxonEvidencepayserviceallowsyoutomanagevideorecordsinadditiontoyourCEWre-cords. Visit www.evidence.com for details.

EvidenceSyncOfflineSoftwareTheEvidenceSyncsoftwarecanbeusedintheOfflinemodeforCEWuserswhodonothaveanAxonEvidenceorEvidence.comLiteaccount.EvidenceSyncOfflineenablesyoutodownloadtheEventlogtoyourlocalcomputerandprintit.Visitwww.evidence.comorwww.axon.comfordetails.

TASER CAM HD RecorderThe TASER CAM HD recorder allows users to capture vital information prior to, during, and after de-ploymentorpotentialdeploymentoftheX26PCEW.TheTASERCAMHDrecorderisanaudio-videorecordingdevice inserted intoa rechargeableX26PCEWpowersupply that replaces thestandardbatterypack.TheTASERCAMHDrecorderisactivatedwhenthesafetyswitchisintheup(ARMED)position.Thereisaboot-uptimedelayofapproximatelytwosecondsafterthesafetyswitchismovedtotheup(ARMED)positionbeforeitstartstorecord.

TheTASERCAMHDbatteryisrechargeableandiscapableofapproximately100five-secondfirings

Page 35: TASER X26P CEW User Manual

31

TASER X26P CEW User Manual

Chapter 6: Optional Accessories

whencompletelycharged.Chargingisaccomplishedthrougha110-voltwalladapterthroughtheUSBcable.

TheTASERCAMHDcanrecordapproximatelyonehourofvideoatmaximumresolutionbeforere-cordingoverpreviousfiles(continuousloopsystem).

VideoandaudioisdownloadedviaaUSBcableandEvidenceSyncsoftwaretoyourlocalcomputerorto Axon Evidence services.

Therealsoisanautomaticshut-down(AS)versionoftheTASERCAMHDrecorderthatemitsanalarmandshutsdowntheenergycycleafterfiveseconds,liketheAPPMandXAPPMbatterypacks.

HolstersSeveralholstersaredesignedforusewiththeX26PCEW.Bothright-andleft-handedconfigurationsare available. Visit our website at www.axon.com for details.

Page 36: TASER X26P CEW User Manual

32

Chapter 7: Additional items

Additional information New TASER brand products are under development. Visit our website at www.axon.com for the latest information.

Seethecurrentproductwarnings,trainingmaterials,licensingagreements,andspecificationsheetsformoreinformationaboutyourTASERproduct.

Product functionsand specificationsmay changewithoutnoticeand theactualproductmay varyfrom the illustrations in this manual.

Axon AcademyTheAxonAcademyisdesignedtoprovidetrainingontheuseofTASER-brandCEWsandAxonEvidence(Evidence.com) services. Training is geared toward the special needs of law enforcement officers,correctionalofficers,medicalpersonnel,themilitary,professionalsecurity,andprivatecitizens.CEWfunctions,medicalissues,devicemaintenance,andpersonalsafetyarejustafewofthetopicscoveredintheofferedcourses.

Ourcadreofinstructorsconsistsofactiveandformerlawenforcementofficersandmilitarytrainers.Many are internationally recognized experts in use of force at all levels with extensive trainingbackgrounds.

All of our instructors are committed to providing high-level training and to forming lasting relationships tosupportourstudentslongaftertheyleavetheAxonAcademy.

For more information visit our website www.axon.com or give us a call at 1.800.978.2737 option 7 or +1.480.905.2000.

Coursescurrentlyofferedorindevelopment:

• TASERConductedEnergyWeaponBasicInstructorCourse

• TASERConductedEnergyWeaponMasterInstructorCourse

• EvidenceCollectionandAnalysisCourse

• BodyWornCameraCertification

Medical ResearchTASERCEWsareamongthemostextensivelystudiedforceoptions.Medicalstudieshavefoundthat

Page 37: TASER X26P CEW User Manual

33

TASER X26P CEW User Manual

Chapter 7: Additional items

modernpacemakersandimplantedcardiacdefibrillatorswithstandautomatedexternaldefibrillators(AEDs)thatareordersofmagnitudestrongerthantheTASERCEWconductedenergypulses.NumerousCEW-relatedmedicalandfieldstudieshavebeenpublished.Formoreinformationgotowww.axon.com.

Seethecurrentproductwarnings,trainingmaterials,licensingagreements,andspecificationsheetsformoreinformationaboutyourTASERproduct.

Radio Waves

AnSPPMtransmissionisinthefrequencyrangeof2402to2480MHz.

Changesormodificationstotheequipmentnotexpresslyapprovedbythemanufacturercouldvoidtheproductwarrantyandtheuser’sauthoritytooperatetheequipment.

Your wireless device is a radio transmitter and receiver. It is designed and manufactured not to exceed theemissionlimitsforexposuretoradiofrequency(RF)energysetbytheFederalCommunicationsCommission (FCC) of the U.S. Government. These limits are part of comprehensive guidelinesand establish permitted levels of RF energy for the general population. The guidelines are basedon standards that were developed by independent scientific organizations through periodic andthoroughevaluationofscientificstudies.Thestandardsincludeasubstantialsafetymargindesignedtoassurethesafetyofallpersons,regardlessofageandhealth.Beforeadevicemodelisavailablefor sale to thepublic, itmustbe testedand certified to the FCC that it doesnotexceed the limitestablishedby thegovernment-adoptedrequirement forsafeexposure.ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttopart15oftheFCCRules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which canbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.

Consult Axon Enterprise Technical Support for help.

FCC/ICNOTICE:ThisdevicemeetsthebodywornhumanexposurelimitsfoundinOETBulletin65,2001,andANSI/IEEEC95.1,1992.Properoperationofthisequipmentaccordingtotheinstructionsfound in this guidewill result in exposure substantially below the FCC’s recommended limits. TocomplywiththeFCCandANSIC95.1RFexposurelimits,thisdevicehasbeentestedforcompliancewithFCCRFExposurelimitsinthetypicalconfiguration.TheradiatedoutputpowerofthiswirelessdeviceisfarbelowtheFCCradiofrequencyexposurelimits.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.

Section8.4ofRSS-GEN

Page 38: TASER X26P CEW User Manual

34

TASER X26P CEW User Manual

Chapter 7: Additional items

ThisDevicecomplieswithIndustryCanadaLicense-exemptRSSstandard(s).Operationissubjecttothefollowingtwoconditions:1)thisdevicemaynotcauseinterference,and2)thisdevicemustacceptanyinterference,includinginterferencethatmaycauseundesiredoperationofthedevice.

Cetappareilestconformeauxnormesd’exemptiondelicenceRSSd’IndustrieCanada.Sonutilisationest soumiseaux conditions suivantes : 1) cet appareil nedoitpas causerdebrouillage, et 2)doitacceptertoutbrouillage,ycomprislebrouillagepouvantentraînerunfonctionnementindésirable.

Section8.3ofRSS-GEN

UnderIndustryCanadaregulations,thisradiotransmittermayonlyoperateusinganantennaofatypeandmaximum(orlesser)gainapprovedforthetransmitterbyIndustryCanada.Toreducepotentialradiointerferencetootherusers,theantennatypeanditsgainshouldbechosensothattheequivalentisotropicallyradiatedpower(e.i.r.p.)isnotgreaterthannecessaryforsuccessfulcommunication.

Conformémentàlaréglementationd’IndustrieCanada,leprésentémetteurradionepeutfonctionnerqu’aumoyend’uneantenned’unseultypeetd’ungainmaximal(ouinférieur)approuvépourl’émetteurparIndustrieCanada.Danslebutderéduirelesrisquesdebrouillageradioélectriquepourlesautresutilisateurs,ilfautchoisirletyped’antenneetsongaindesortequelapuissanceisotroperayonnéeéquivalente(p.i.r.e.)nedépassepascellerequisepourétablirunecommunicationsatisfaisante.

THISMODELDEVICEMEETSTHEGOVERNMENT’SREQUIREMENTSFOREXPOSURETORADIOWAVES.

Declaration of ConformityAxonEnterprise,Inc.declaresthatthisAxonsystemisincompliancewiththerequirementsandotherrelevantprovisionsoftheRadioEquipmentDirective (RED)2014/53/EUandtheDirective2014/30/EUregardingelectromagneticcompatibility.AcopyoftheoriginalDeclarationofConformitycanbefound at www.axon.com.

Compliance MarksMSIP (South Korea) Compliance Information

Applicant Name: Axon Enterprise, Inc.

Manufacturer/ManufacturerCountry:AxonEnterprise,Inc./USA

Nameofequipment/modelname:Specificlowpowerwirelessdevice(wirelessdeviceforwirelessdatacommunicationsystem)/T00074

CertificationNumber:R-CRM-CEW-T00074

Yearofmanufacture:separatemarking

Thisequipmentisintendedforhomeuse(ClassB)forelectromagneticcompatibilityandisintendedforhomeuseandmaybeusedinallareas.

Page 39: TASER X26P CEW User Manual

35

TASER X26P CEW User Manual

Chapter 7: Additional items

RCPAXT018-0158

NOMOR: 55876/SDPPI/2018;

PLG ID: 7277

AGREE PART L’ANRT MAROC

Numéro d´agrément: MR 18066 ANRT 2018

Date d´agrément: 26 NOV 2018

Page 40: TASER X26P CEW User Manual

Productfunctionsandspecificationsmaychangewithoutnoticeandtheactualproductmayvaryfromtheillustrationsinthismanual.

WindowsisatrademarkofMicrosoftCorporation.

a, c, Axon, Axon Evidence, Axon Flex, X2, X26, TASER, d, and ©aretrademarksofAxonEnterprise,Inc.,someofwhichareregisteredintheUSandothercountries.Formoreinformation,visitwww.axon.com/legal.Allrightsreserved.

© 2020 Axon Enterprise, Inc.

MMU0042 Rev: L