Tank Volumes & Conversions

Tank VolumesRectangular Tank (on its Side or Upright)Capacities per cmm30.173TANK INPUTbbls1.09Length of the Tank, m7.00ft36.117.263125Width of Tank, m2.50US gallons46Hight of Tank, m2.00Cdn gallons38Pump Intake (suction) hight, cm15.0or 1.0m3 perTank wall-thickness, mm12.5cm5.79FLUID INPUTor 1.0bbl perFluid added (bought) Yesterday, Litres12000in0.36Yesterday's Hight of fluid in the tank, m1.10Capacity per inToday's Hight of fluid in the tank, m1.00bbls2.76Total Holding CapacityTotal Net CapacityFluid Used last 24hrsTotal Fluid in TankNet Fluid in Tank6.9750.15Litres34095Litres31505Litres13726Litres17263Litres146742.4752.58946875m334.095m331.505m313.726m317.263m314.6741.975bbls214.45bbls198.16bbls86.34bbls108.58bbls92.29vol yesterdayft31204.0ft31112.6ft3484.7ft3609.6ft3518.218.9894375US gallons9007US gallons8323US gallons3626US gallons4560US gallons387613.726Cdn gallons7500Cdn gallons6930Cdn gallons3019Cdn gallons3797Cdn gallons3228Upright Cylindrical Flat Ended TankCapacities per cmm30.089bbls0.56TANK INPUTft33.2Width of Tank, m3.40US gallons24Hight of Tank, m7.00Cdn gallons20Pump Intake (suction) hight, cm15.0or 1.0m3 perTank wall-thickness, mm12.5cm11.18FLUID INPUTor 1.0bbl perFluid added (bought) Yesterday, Litres12000in0.70Yesterday's Hight of fluid in the tank, m1.40Capacity per inToday's Hight of fluid in the tank, m1.00bbls1.43Total Holding CapacityTotal Net CapacityFluid Used last 24hrsTotal Fluid in TankNet Fluid in TankLitres62400Litres61058Litres4454Litres8946Litres7604w3.3750.15m362.400m361.058m34.454m38.946m37.604h6.9751.3419263932bbls392.48bbls384.04bbls28.01bbls56.27bbls47.83a8.95ft32203.6ft32156.2ft3157.3ft3315.9ft3268.5y1.40US gallons16484US gallons16130US gallons1177US gallons2363US gallons20094.454Cdn gallons13726Cdn gallons13431Cdn gallons980Cdn gallons1968Cdn gallons1673Some Useful ConversionsINPUTOUTPUTINPUTOUTPUTfrom m1000.0to ft3280.8from ft7000.0to m2133.6from mm250.8to in9.87from in100.0to mm2540.00from kg100.0to lbs220.5from lbs100.0to kg45.4from daN18000to lbf40466from lbf3600to daN1601from kPa1000.0to psi145.04from psi14.50to kPa100.0from kg/m31150.0to ppg9.597from ppg8.345to kg/m31000.0from kg/m31150.0to lbs/BBL403.083from lbs/BBL10.000to kg/m328.5from kg/m31150.0to lbs/ft371.792from lbs/ft310.000to kg/m3160.2from cm31000.0to in361.0from in361.00to cm3999.6from Litres10.00to us gallons2.64fm us gallons10.00to Litres37.85from m31.00to BBLs6.29from BBLs10.00to m31.59from m31.00to us gallons264.17fm us gallons300.00to m31.14from m31.00to ft335.31from ft350.00to m31.42from m31.00to cdn gallons219.97fm cdn gallons500.00to m32.27Degrees oC15.0Degrees oF59.0Degrees oF60.0Degrees oC15.6

length of tankMeasured to a 2 or 3 cm above the suction line (from inside the tank).For Fluid used Last 24hrs calculations, enter here the value that is currently at Today (do it before you enter there today's new Hight value). Or you can enter 0.Written by Vass KaratzasWHITE TOWER CONSULTING Ltd.Comments: [email protected] of tankNet Capacity = Working Capacity = Tank Capacity above the Suction line.

Note: If Pump Intake Hightis = 0, then, the Net Capacity = Holding Capacity.Net Fluid = Fluid Amount above the pump intake.hight of tankfluid levelIf you enter here 0, calculations will assume that you have entered above, the inside Length, Width, and Hight dimentions of the tank.fluid hightwidth of tankhight of tankfluid levelfluid hightMeasured to a 2 or 3 cm above the suction line (from inside the tank).If you enter here 0, calculations will assume that you have entered above, the inside Width and Hight dimentions of the tank.For Fluid used Last 24hrs calculations, enter here the value that is currently at Today (do it before you enter there today's new Hight value). Or you can enter 0.Net Capacity = Working Capacity = Tank Capacity above the Suction line.

Note: If Pump Intake Hightis = 0, then, the Net Capacity = Holding Capacity.Net Fluid = Fluid Amount above the pump intake.

More TanksCylindrical Flat Ended Tank on its Sideover halfY0.2-0.1TANK INPUTR1.01.0Length of the Tank, m7.00tr. Area0.2-0.1Hight of Tank, OD, m2.0077.5784.92Pump Intake (suction) hight, cm20.02155.15169.83Tank wall-thickness, mm12.5Area1.94819742051.5322251933FLUID INPUTVolume13.588677007810.687270723Fluid added (bought) Yesterday, Litres12000less than halfYesterday's Hight of fluid in the tank, m0.90Y-0.2130.10.788Today's Hight of fluid in the tank, m1.20R1.01.00.6tr. Area-0.2050.0860.46977.5784.9237.11Total Holding CapacityTotal Net CapacityFluid Used last 24hrsTotal Fluid in TankNet Fluid in Tank2155.1466660089169.832983780274.2219529139Litres21368Litres20235Litres7892Litres13589Litres12456Area1.5252014481.35918575660.1624099371m321.368m320.235m37.892m313.589m312.456Volume10.63828009969.48032065221.1328093115bbls134.40bbls127.28bbls49.64bbls85.47bbls78.357.892ft3754.6ft3714.6ft3278.7ft3479.9ft3439.9L = 6.98m39.480US gallons5645US gallons5346US gallons2085US gallons3590US gallons3290d = 1.98Cdn gallons4700Cdn gallons4451Cdn gallons1736Cdn gallons2989Cdn gallons2740r = 0.988mCylindrical Round Ended Tank on its Sideover halfY-0.41.4-0.21.2TANK INPUTR0.90.91.01.0Length of the Tank, m7.00tr. Area-0.4-0.2Hight of Tank, OD, m2.0066.9079.05Pump Intake (suction) hight, cm20.02133.79158.11Tank wall-thickness, mm12.5Area1.57303431351.5362710967FLUID INPUTVolume11.90188171190.890641517312.20321908761.4493214109Fluid added (bought) Yesterday, Litres3000less than halfYesterday's Hight of fluid in the tank, m0.80Y0.38750.60.18750.60.7880.2Today's Hight of fluid in the tank, m0.60R0.90.91.01.00.60.6tr. Area0.3520.1820.46966.9079.0537.11Total Holding CapacityTotal Net CapacityFluid Used last 24hrsTotal Fluid in TankNet Fluid in Tank2133.7915350538158.109205807574.2219529139Litres25478Litres24226Litres5748Litres6397Litres5144Area0.78658069031.16369662510.1624099371m325.478m324.226m35.748m36.397m35.144Volume6.39670634910.89064151739.14490283970.99902646381.25258488940.1157153294bbls160.25bbls152.38bbls36.16bbls40.23bbls32.365.748ft3899.8ft3855.5ft3203.0ft3225.9ft3181.7L = 7.00m39.145US gallons6731US gallons6400US gallons1519US gallons1690US gallons1359d = 1.975Cdn gallons5604Cdn gallons5329Cdn gallons1264Cdn gallons1407Cdn gallons1132r = 0.988mSpherical TankConical TankTANK INPUTTANK INPUTWidth or Hight of Tank, m2.002.00m, Width of the BaseTank wall-thickness, mm12.503.00m, Hight of the TankFLUID INPUT20.00mm, Tank wall-thicknessHight of fluid in the tank, m1.00FLUID INPUT2.50m, Hight of fluid in the TankTotal Holding CapacityFluid in TankTotal Holding CapacityFluid in TankLitres4034Litres2055Litres2977Litres2966m34.034m32.055m32.977m32.966bbls25.37bbls12.93bbls18.72bbls18.65ft3142.4ft372.6ft3105.1ft3104.7US gallons1066US gallons543US gallons786US gallons783Cdn gallons887Cdn gallons452Cdn gallons655Cdn gallons6521.9752.960000.98750.98000abovetop angle18.31870.01.0r10.15229729730.98740.460002.0551251942below1.0-0.01251.02.0551251942

r = 0.988mfluid hightlength of tankhight of tankfluid levelMeasure to a 2 or 3 cm above the suction line (from inside the tank).For Fluid used Last 24hrs calculations, enter here the value that is currently at Today (do it before you enter there today's new Hight value). Or, you can enter 0.fluid hightlength of tankhight of tankFor Fluid used Last 24hrs calculations, enter here the value that is currently at Today (do it before you enter there today's new Hight value). Or you can enter 0.To Build a Deep-Stick Table, enter here the Hight increaments you like to use and record results as in the example: Tank length, 7.0m (22.97ft) Higth, 2.0m (6.56ft) Intake, 20.0cm (7.9in) Wall, 15.9mm (0.625in or 5/8") Todays Fluid Hight, 10cm (4in) increaments Fluid Higth Total Vol Net Vol cm in m3 bbl m3 bbl 20 8.0 1.1 7.1 0.0 0.0 30 12 2.0 12.8 0.9 5.7 40 16 3.1 19.4 2.0 12.3 50 20 4.2 26.7 3.1 19.6 60 24 5.5 34.4 4.3 27.3 70 .... ..... ..... ..... ..... .... ....If you enter here 0, calculations will assume that you have entered above, the inside Length and Hight dimentions of the tank.Net Capacity = Working Capacity = Tank Capacity above the Suction line.

Note: If Pump Intake Hightis = 0, then, the Net Capacity = Holding Capacity.Net Capacity = Working Capacity = Tank Capacity above the Suction line.

Note: If Pump Intake Hightis = 0, then, the Net Capacity = Holding Capacity.Measure to a 2 or 3 cm above the suction line (from inside the tank).If you enter here 0, calculations will assume that you have entered above, the inside Length and Hight dimentions of the tank.To Build a Deep-Stick Table, enter here the Hight increaments you like to use and record results as in the example: Tank length, 7.0m (22.97ft) Higth, 2.0m (6.56ft) Intake, 20.0cm (7.9in) Wall, 15.9mm (0.625in or 5/8") Todays Fluid Hight, 10cm (4in) increaments Fluid Higth Total Vol Net Vol cm in m3 bbl m3 bbl 20 8.0 1.3 7.9 0.0 0.0 30 12 2.3 14.5 1.1 6.6 40 16 3.5 22.2 2.3 14.3 50 20 4.9 30.8 3.7 23.0 60 24 6.4 40.1 5.1 32.3 70 .... ..... ..... ..... ..... ..... ....r = 0.988mNet Fluid = Fluid Amount above the pump intake.Net Fluid = Fluid Amount above the pump intake.Written by Vass KaratzasWhite Tower Consulting Ltd.Comments: [email protected] levelIf you enter here 0, calculations will assume that you have entered above, the inside Diametre of the tank.Width = Hight = the Diametre of a sphere.DiametreIf you enter here 0, calculations will assume that you have entered above, the inside Width and Hight of the tank.hight of tankwidth of tank