Tank Monitoring Sensor

Installation Guide

360Tanks.com Feb 2017

Tank Monitoring Sensor Installation Guide

Support If at any time during your installation you need help, please contact: [email protected]

Box Contents

Installation Tools Required 1. Ladder - to safely reach the top of the tank 2. 50mm / 2 inch Hole Saw 3. Cordless drill 4. Outdoor silicone sealant 5. Spirit Level

Safety

● Do not open the sensor when on top of the tank. Ensure you are on the ground. ● The sensor contains internal batteries. Do not open the unit enclosure unless the area is

known to be free of ignitable concentrations. ● Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry.

ESD damage occurs when electronic components are improperly handled and can result in complete or intermittent failures.

● The sensor is intended for fixed installation, where the installation is intended to minimize the risk from ESD.

www.360Tanks.com Tank Monitoring Sensor Installation Guide Feb 20172 / 8

Tank Monitoring Sensor Installation Guide

Installation Steps

1

Make a note of the IMEI number of the sensor you are installing. This can be found on the sensor label.

The IMEI is found on the sensor label and uniquely identifies the sensor

2 ↑

Carefully undo the 4 screws on the sensor using the Allen key provided and open the sensor.

Make sure you are on the ground and in a safe environment when you are doing steps 1 - 4. Do not open the unit when on top of the tank.

3

Plug in the battery to the black battery terminal on the board.

The LED lights on the unit will start flashing every time the unit takes a reading. Once the battery is connected, this will occur hourly or if you manually swipe with the magnet.

4 ↓

Put the lid and screws back on the sensor. Ensure the lid is orientated correctly. Line up the battery holding compartment on the inside of the lid with the battery.

www.360Tanks.com Tank Monitoring Sensor Installation Guide Feb 20173 / 8

Tank Monitoring Sensor Installation Guide

5

Locate and mark suitable position on the tank for the sensor.

1. Sensor must be mounted horizontally, not at an angle on pitched roof tanks

2. Sensor to the maximum liquid level distance must be greater than 300mm. Max liquid level is often the bottom of the overflow.

3. Sensor horizontal distance to the tank wall must be greater than 500mm

4. On corrugated roofs, mount on the top of the corrugation, not in the channel

5. Drill a 50mm hole at the marked location For your safety, stay on the ladder. Tank manufacturers do not recommend climbing on the tank roof.

6

1. Fix the sensor to the mount by inserting the sensor into the mount hole

2. Screw the mount adapter to the sensor

www.360Tanks.com Tank Monitoring Sensor Installation Guide Feb 20174 / 8

Tank Monitoring Sensor Installation Guide

7

1. Position the mounted sensor over the hole

8

On pitched roofs, ensure the sensor is horizontal. To do this,

1. Loosen the mount wing nuts, adjust the angle of the sensor cradle then retighten the nuts.

2. You may also need to swivel the base of the sensor to ensure the cradle is rotating up the slope, not sideways to the slope.

9

1. Secure the mount to the tank with the 4 screws. Screw into the mount channel

2. Run a bead of silicone sealant around the threaded adapter in the 50mm hole to seal it.

www.360Tanks.com Tank Monitoring Sensor Installation Guide Feb 20175 / 8

Tank Monitoring Sensor Installation Guide

10 Measure and record the 1. Sensor to Overflow distance in mm 2. Overflow to Base distance in mm

11

1. Sign in to 360Tanks.com 2. Select the Status chart (the chart shows a

Pending sensor) 3. Find the Pending activation sensor that

matches the IMEI number of the unit you have installed.

4. Select

5. Follow the configuration screens entering in the tank installation measurements you took earlier.

6. Once the configuration screens are complete, your sensor view will now show ‘Waiting for first time connection’.

You can sign in and configure with your phone while still onsite. You can also update the configuration and

measurement settings at any time.

www.360Tanks.com Tank Monitoring Sensor Installation Guide Feb 20176 / 8

Tank Monitoring Sensor Installation Guide

12

1. Cellular/Mobile and GPS LED 2. Battery LED

Wake up the unit to force it to take and upload an immediate measurement. Swipe the magnet provided along the side of the unit next to the magnet sticker. The unit will wake up and the LED lights will flash.

Check the tank level measurement on the monitoring application. If you need to adjust the configuration measurements you can anytime through the application by selecting the

sensor from the sensor page (select its name) then select Edit.

LED Lights

Cellular/Mobile and GPS LED

Purple ● The sensor is awake

Red ● Slowly Blinking: Performing GPS location. The LED slowly blinks red for an extended period the first time the device performs a GPS location acquisition

● Quickly blinking: Searching for the cellular network.

Blue ● Blinking: Connected to the cellular/mobile network and attempting to communicate with 360Tanks services.

● Solid light: Successfully sent data to 360Tanks service; turns off after a few seconds.

Battery LED Purple ● The sensor is awake

Red ● Red blinking: Indicates the battery life is low and the battery is due for replacement.

Blue ● Blue blinking: Indicates the battery life is ok.

www.360Tanks.com Tank Monitoring Sensor Installation Guide Feb 20177 / 8

Tank Monitoring Sensor Installation Guide

Installation FAQs Please check our online Frequently Asked Questions regarding installations. Find these at www.360tanks.com then select to FAQ at the top of the page. If your question is not answered here please contact us at: [email protected]

Limited Warranty Upon Your payment in full of Your Sensors Purchase Price and Our delivery to You of Your Sensors, we warrant to You that for a period of the earlier of: (a) three years following the delivery of Your Sensors to You; or (b) the expiration or termination of Your Subscription to the 360Tanks Service (the “Limited Warranty Period”), Your Sensors will operate in accordance with the written specifications for the Sensors (the “Sensor Specifications”) located at www.360tanks.com (the “Limited Warranty”). The Limited Warranty does not apply in the event that any part of Your Sensors (including any of Our Software therein) have been: (i) used other than in accordance with these T&Cs, the Sensor Specifications or other written operating instructions provided by Us or Our agents to You; (ii) modified, repaired, serviced, maintained or altered by anyone other than Us or one of Our authorized agents without Our prior written approval in each instance; (iii) combined with or installed on/with operating systems, hardware or other equipment that do not constitute Our Hardware or Our Software; (iv) used or installed not in accordance with the Sensor Specifications; (v) damaged by causes beyond the Our reasonable control; or (vi) sold or transferred to any Person other than You. The Limited Warranty extends only to You and does not extend to any other Person. EXCEPT FOR THE LIMITED WARRANTY, YOUR SENSORS ARE PROVIDED ON AN “AS IS” BASIS WITHOUT ANY WARRANTY OR CONDITION WHATSOEVER, AND WE EXPRESSLY DISCLAIM ALL OTHER IMPLIED OR STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY, TITLE, NON-INFRINGEMENT, AND FITNESS FOR A PARTICULAR PURPOSE. WE DO NOT WARRANT THAT YOUR SENSORS WILL MEET YOUR REQUIREMENTS OR THAT THE OPERATION OF YOUR SENSORS WILL BE UNINTERRUPTED OR ERROR-FREE.