2
CAPACITIVE AND RESISTIVE T . E . CA . R . DIACARE 7000 DIACARE 7000 RE RECHARGEABLE You pay just when you use it! NEW! MADE IN ITALY

T E CA R - FISIORENT...STRONG POINTS • MULTIFREQUENCYDIFFERENT SELECTABLE WORKING FREQUENCIES: 400kHz - 470kHz - 700kHz - 1000kHz - 1200kHz. THE ABILITY TO HAVE MULTIPLE FREQUENCIES

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: T E CA R - FISIORENT...STRONG POINTS • MULTIFREQUENCYDIFFERENT SELECTABLE WORKING FREQUENCIES: 400kHz - 470kHz - 700kHz - 1000kHz - 1200kHz. THE ABILITY TO HAVE MULTIPLE FREQUENCIES

C A PA C I T I V E A N D R E S I S T I V ET .E .CA .R .

DIACARE 7000DIACARE 7000 RERECHARGEABLEYou pay just when you use it!

NEW!

MADE IN ITALY

Page 2: T E CA R - FISIORENT...STRONG POINTS • MULTIFREQUENCYDIFFERENT SELECTABLE WORKING FREQUENCIES: 400kHz - 470kHz - 700kHz - 1000kHz - 1200kHz. THE ABILITY TO HAVE MULTIPLE FREQUENCIES

STRONG POINTS• MULTIFREQUENCYDIFFERENT SELECTABLE WORKING FREQUENCIES: 400kHz - 470kHz - 700kHz - 1000kHz - 1200kHz.THE ABILITY TO HAVE MULTIPLE FREQUENCIES ALLOWS THE OPERATOR TO WORK IN A TIMELY MANNER TO DIFFERENT DEPTHS.

• AUTOMATIC FREQUENCY SCANNINGTHE AUTOMATIC SCANNING PROGRAM ALLOWS, WITHIN THE SAME TREATMENT, TO TRANSPORT ENERGY IN AN UNIFORM WAY, BEFORE IN THE DEEPER TISSUES, THEN IN THE MIDDLE, AND FINALLY IN THE MORE SUPERFICIAL TISSUES.

• TRANSDERMAL DELIVERYTHE PROGRAM ALLOWS TO FACILITATE THE ABSORPTION OF THE ACTIVE PRINCIPLE OF A DRUG OR CREAM.

• AUTOMATIC APPLICATION MODEAFTER CHOOSING THE PARAMETERS AND PLACING THE ELECTRODES, SIMPLY START THE AUTOMATIC PROGRAM.THE OPERATOR, IN THIS WAY, WILL HAVE THE POSSIBILITY TO INTEGRATE THE THERAPY WITH MANUAL TECHNIQUES.

• ATHERMY TREATMENTSBIOSTIMULATION OF TISSUES WITHOUT HEAT GENERATION THANKS TO THE CONTROLLED PULSED OUTPUT.

• PULSED TREATMENTSABILITY TO USE PROGRAMS WITH PULSED EMISSION OF DIFFERENT RATIO (DUTY CYCLE).THIS, FOR EXAMPLE, ALLOWS TO MAINTAIN HIGH THE ENERGY TRANSFERRED TO THE TISSUES PRESERVING, AT THE SAME TIME, A GOOD TEMPERATURE CONTROL.

TECHNICAL FEATURES

Automatic application mode

Athermy treatments

Automatic frequency scanning

Transdermal delivery

Preset programs

Treatment modality: capacitive and resistive

Power: 320 W ±5%

Outputs: 2

Power supply: mains

CAP-RES monopolar electrode size: Ø 30-50-70 mm

Frequency: 400 - 470 - 700 - 1000 - 1200 kHz ± 10%

Pulsed treatments

Size: 515x170x340 mm

CAPACITIVE RESISTIVE MONOTRODE TOUCH SCREEN COLOR DISPLAY MULTIFREQUENCY AUTOMATIC FREQ.SCANNING

TRANSDERMALDELIVERY

AUTOMATIC APPLICATION MODE

ATHERMY TREATMENTS

PULSED TREATMENTS

DOMINO S.R.L. - Via Vittorio Veneto, 52 - 31013 Codognè (TV) - ITALY - Phone (+39) 0438.7933

www.globuscorporation.com