16
SYSTEMS OVERVIEW

SYSTEMS OVERVIEW

  • Upload
    tracen

  • View
    44

  • Download
    0

Embed Size (px)

DESCRIPTION

SYSTEMS OVERVIEW. Subsea Buoy Interior / Tanks Legs Topsides / Superstructure. CONTENTS | 2. SYSTEMS OVERVIEW Subsea. SUBSEA | 3. Subsea Process Equipment / under insulation. Structural Steel. SUBSEA | 4. SYSTEMS OVERVIEW Buoy. BUOY | 5. Buoy Atmospheric. - PowerPoint PPT Presentation

Citation preview

Page 1: SYSTEMS  OVERVIEW

SYSTEMS OVERVIEW

Page 2: SYSTEMS  OVERVIEW

• Subsea• Buoy• Interior / Tanks• Legs• Topsides / Superstructure

CONTENTS | 2

Page 3: SYSTEMS  OVERVIEW

SUBSEA | 3

SYSTEMS OVERVIEWSubsea

Page 4: SYSTEMS  OVERVIEW

SUBSEA | 4

CERTIFIED NORSOK M501 rev 5 - System 1 µm

PHENGUARD 930 100

PHENGUARD 935 100

PHENGUARD 940 100

SubseaProcess Equipment / under insulation

CERTIFIED NORSOK M501 rev 5 - System 1 µm

SIGMAPRIME 700 175

SIGMAPRIME 700 175

CERTIFIED NORSOK M501 rev 5 - System 1 µm

PHENGUARD 930 100

PHENGUARD 935 100

PHENGUARD 780 100

Structural Steel

CERTIFIED NORSOK M501 rev 5 - System 7 µm

SIGMASHIELD 1200 400

SIGMASHIELD 1200 400

Page 5: SYSTEMS  OVERVIEW

BUOY | 5

SYSTEMS OVERVIEWBuoy

Page 6: SYSTEMS  OVERVIEW

BUOY | 6

Splash and atmospheric, 3 coatCERTIFIED NORSOK M501 rev 5 - System 7

µm

SIGMASHIELD 1200 400

SIGMASHIELD 1200 400

SIGMASHIELD 550* 50

BuoyAtmospheric

Splash and atmospheric, 2 coatCERTIFIED NORSOK M501 rev 5 - System 7 µm

SIGMASHIELD 1200 400

SIGMASHIELD 1200 400

Splash Zone

Splash and atmospheric, 4 coatCERTIFIED NORSOK M501 rev 5 - System 7

µm

SIGMAWELD 199 20

SIGMAPRIME 200 100

SIGMASHIELD 460 250

SIGMADUR 550* 50

3 coatCERTIFIED NORSOK M501 rev 5 - System 7

µm

SIGMAZINC 109 HS 100

SIGMASHIELD 420 250

SIGMADUR 550* 50

2 coatCERTIFIED NORSOK M501 rev 5 - System 7 µm

SIGMAZINC 109 HS 100

SIGMASHIELD 420 250

Splash and atmospheric, 3 coatCERTIFIED NORSOK M501 rev 5 - System 7 µm

SIGMAWELD 199 20

SIGMAPRIME 200 100

SIGMASHIELD 460 250

Page 7: SYSTEMS  OVERVIEW

INTERIOR / TANKS | 7

SYSTEMS OVERVIEWInterior / Tanks

Page 8: SYSTEMS  OVERVIEW

INTERIOR / TANKS | 8

ISO 12944-5 C3 µm

SIGMAPRIME 200 100

SIGMAPRIME 200 100

InteriorEngine RoomNew Build & Full Maintenance

ISO 12944-5 C3 High solids µm

SIGMAPRIME 700 100

SIGMAPRIME 700 100

New Build & Full Maintenance

CERTIFIED ISO 12944-6 C5 High µm

SIGMACOVER 280 50

SIGMACOVER 630 130

SIGMADUR 550 60

Pump RoomNew Build & Full Maintenance

CERTIFIED ISO 12944-6 C5 High µm

SIGMACOVER 280 50

SIGMACOVER 630 130

SIGMADUR 550 60

ForecastleNew Build & Full Maintenance

Page 9: SYSTEMS  OVERVIEW

INTERIOR / TANKS | 9

IMO-PSPC µm

SIGMAPRIME 700 160

SIGMAPRIME 700 160

TanksBalast WaterNew Build & Full Maintenance

Crude oil – 60°C µm

SIGMAGUARD CSF 650 300

CargoNew Build & Full Maintenance

CERTIFIED ISO 12944-6 C5 High µm

PHRNGUARD 930 100

PHRNGUARD 935 100

PHRNGUARD 940 100

Slop / Produced WaterNew Build & Full Maintenance

CERTIFIED ISO 12944-6 C5 High µm

SIGMACOVER 280 50

SIGMACOVER 630 130

SIGMADUR 550 60

Coffer DamNew Build & Full Maintenance

Crude oil - 90°C µm

NOVAGUARD 840 300

Page 10: SYSTEMS  OVERVIEW

INTERIOR / TANKS | 10

CERTIFIED KIWA approved µm

SIGMAGUARD CSF 585 300

TanksDrinking WaterNew Build & Full Maintenance

CERTIFIED ISO 12944-6 C5 High µm

SIGMACOVER 280 50

SIGMACOVER 630 130

SIGMADUR 550 60

Void SpacesNew Build & Full Maintenance

Page 11: SYSTEMS  OVERVIEW

LEGS | 11

SYSTEMS OVERVIEWLegs

Page 12: SYSTEMS  OVERVIEW

LEGS | 12

CERTIFIED NORSOK M501 rev 5 - System 7Splash zone, 2 coat

µm

SIGMASHIELD 1200 400

SIGMASHIELD 1200 400

Underwater-BoottopNew Build & Full Maintenance

CERTIFIED NORSOK M501 rev 5 - System 1 µm

SIGMAZINC 109 HS 75

SIGMAPRIME 200 200

SIGMADUR 550 50

Topside-BoottopNew Build & Full Maintenance

CERTIFIED NORSOK M501 rev 5 - System 7Splash zone, 3 coat

µm

SIGMAWELD 199 20

SIGMAPRIME 200 100

SIGMASHIELD 460 250

CERTIFIED NORSOK M501 rev 5 - System 72 coat

µm

SIGMAZINC 109 HS 100

SIGMASHIELD 420 250

CERTIFIED NORSOK M501 rev 5 - System 1 µm

SIGMAZINC 109 HS 75

SIGMAPRIME 200 200

SIGMADUR 550 50

DeckNew Build & Full Maintenance

Page 13: SYSTEMS  OVERVIEW

TOPSIDES / SUPERSTRUCTURES | 13

SYSTEMS OVERVIEWTopsides / Superstructures

Page 14: SYSTEMS  OVERVIEW

TOPSIDES / SUPERSTRUCTURES | 14

NORSOK system 1 µm

SIGMAZINC 109 HS 75

SIGMAPRIME 200 200

SIGMADUR 550 50

Structural SteelNew Build & Full Maintenance

CERTIFIED ISO 12944-6 C5 High µm

SIGMACOVER 280 50

SIGMACOVER 630 130

SIGMADUR 550 60

Accommodation InternalNew Build & Full Maintenance

CERTIFIED NORSOK M501 rev 5 - System 1 µm

SIGMAZINC 109 HS 75

SIGMAPRIME 200 200

SIGMADUR 550 50

Accommodation ExternalNew Build & Full Maintenance

Page 15: SYSTEMS  OVERVIEW

TOPSIDES / SUPERSTRUCTURES | 15

120°C µm

SIGMAZINC 109 HS 75

SIGMAPRIME 200 200

SIGMADUR 550 50

PipingNew Build & Full Maintenance

120°C - 150°C µm

SIGMAGUARD 730 125

SIGMAGUARD 730 125

New Build & Full Maintenance

150°C - 230°C µm

SIGMATHERM 230 125

SIGMATHERM 230 125

450°C - 540°C µm

SIGMATHERM 540 25

SIGMATHERM 540 25

230°C - 450°C µm

SIGMAZINC 158 75

SIGMATHERM 540 25

Page 16: SYSTEMS  OVERVIEW

TOPSIDES / SUPERSTRUCTURES | 16

120°C µm

SIGMAZINC 109 HS 75

SIGMAPRIME 200 200

SIGMADUR 550 50

Process Equipment ExternalNew Build & Full Maintenance

120°C - 150°C µm

SIGMAGUARD 730 125

SIGMAGUARD 730 125

New Build & Full Maintenance

150°C - 230°C µm

SIGMATHERM 230 125

SIGMATHERM 230 125

450°C - 540°C µm

SIGMATHERM 540 25

SIGMATHERM 540 25

230°C - 450°C µm

SIGMAZINC 158 75

SIGMATHERM 540 25