Upload
tracen
View
44
Download
0
Embed Size (px)
DESCRIPTION
SYSTEMS OVERVIEW. Subsea Buoy Interior / Tanks Legs Topsides / Superstructure. CONTENTS | 2. SYSTEMS OVERVIEW Subsea. SUBSEA | 3. Subsea Process Equipment / under insulation. Structural Steel. SUBSEA | 4. SYSTEMS OVERVIEW Buoy. BUOY | 5. Buoy Atmospheric. - PowerPoint PPT Presentation
Citation preview
SYSTEMS OVERVIEW
• Subsea• Buoy• Interior / Tanks• Legs• Topsides / Superstructure
CONTENTS | 2
SUBSEA | 3
SYSTEMS OVERVIEWSubsea
SUBSEA | 4
CERTIFIED NORSOK M501 rev 5 - System 1 µm
PHENGUARD 930 100
PHENGUARD 935 100
PHENGUARD 940 100
SubseaProcess Equipment / under insulation
CERTIFIED NORSOK M501 rev 5 - System 1 µm
SIGMAPRIME 700 175
SIGMAPRIME 700 175
CERTIFIED NORSOK M501 rev 5 - System 1 µm
PHENGUARD 930 100
PHENGUARD 935 100
PHENGUARD 780 100
Structural Steel
CERTIFIED NORSOK M501 rev 5 - System 7 µm
SIGMASHIELD 1200 400
SIGMASHIELD 1200 400
BUOY | 5
SYSTEMS OVERVIEWBuoy
BUOY | 6
Splash and atmospheric, 3 coatCERTIFIED NORSOK M501 rev 5 - System 7
µm
SIGMASHIELD 1200 400
SIGMASHIELD 1200 400
SIGMASHIELD 550* 50
BuoyAtmospheric
Splash and atmospheric, 2 coatCERTIFIED NORSOK M501 rev 5 - System 7 µm
SIGMASHIELD 1200 400
SIGMASHIELD 1200 400
Splash Zone
Splash and atmospheric, 4 coatCERTIFIED NORSOK M501 rev 5 - System 7
µm
SIGMAWELD 199 20
SIGMAPRIME 200 100
SIGMASHIELD 460 250
SIGMADUR 550* 50
3 coatCERTIFIED NORSOK M501 rev 5 - System 7
µm
SIGMAZINC 109 HS 100
SIGMASHIELD 420 250
SIGMADUR 550* 50
2 coatCERTIFIED NORSOK M501 rev 5 - System 7 µm
SIGMAZINC 109 HS 100
SIGMASHIELD 420 250
Splash and atmospheric, 3 coatCERTIFIED NORSOK M501 rev 5 - System 7 µm
SIGMAWELD 199 20
SIGMAPRIME 200 100
SIGMASHIELD 460 250
INTERIOR / TANKS | 7
SYSTEMS OVERVIEWInterior / Tanks
INTERIOR / TANKS | 8
ISO 12944-5 C3 µm
SIGMAPRIME 200 100
SIGMAPRIME 200 100
InteriorEngine RoomNew Build & Full Maintenance
ISO 12944-5 C3 High solids µm
SIGMAPRIME 700 100
SIGMAPRIME 700 100
New Build & Full Maintenance
CERTIFIED ISO 12944-6 C5 High µm
SIGMACOVER 280 50
SIGMACOVER 630 130
SIGMADUR 550 60
Pump RoomNew Build & Full Maintenance
CERTIFIED ISO 12944-6 C5 High µm
SIGMACOVER 280 50
SIGMACOVER 630 130
SIGMADUR 550 60
ForecastleNew Build & Full Maintenance
INTERIOR / TANKS | 9
IMO-PSPC µm
SIGMAPRIME 700 160
SIGMAPRIME 700 160
TanksBalast WaterNew Build & Full Maintenance
Crude oil – 60°C µm
SIGMAGUARD CSF 650 300
CargoNew Build & Full Maintenance
CERTIFIED ISO 12944-6 C5 High µm
PHRNGUARD 930 100
PHRNGUARD 935 100
PHRNGUARD 940 100
Slop / Produced WaterNew Build & Full Maintenance
CERTIFIED ISO 12944-6 C5 High µm
SIGMACOVER 280 50
SIGMACOVER 630 130
SIGMADUR 550 60
Coffer DamNew Build & Full Maintenance
Crude oil - 90°C µm
NOVAGUARD 840 300
INTERIOR / TANKS | 10
CERTIFIED KIWA approved µm
SIGMAGUARD CSF 585 300
TanksDrinking WaterNew Build & Full Maintenance
CERTIFIED ISO 12944-6 C5 High µm
SIGMACOVER 280 50
SIGMACOVER 630 130
SIGMADUR 550 60
Void SpacesNew Build & Full Maintenance
LEGS | 11
SYSTEMS OVERVIEWLegs
LEGS | 12
CERTIFIED NORSOK M501 rev 5 - System 7Splash zone, 2 coat
µm
SIGMASHIELD 1200 400
SIGMASHIELD 1200 400
Underwater-BoottopNew Build & Full Maintenance
CERTIFIED NORSOK M501 rev 5 - System 1 µm
SIGMAZINC 109 HS 75
SIGMAPRIME 200 200
SIGMADUR 550 50
Topside-BoottopNew Build & Full Maintenance
CERTIFIED NORSOK M501 rev 5 - System 7Splash zone, 3 coat
µm
SIGMAWELD 199 20
SIGMAPRIME 200 100
SIGMASHIELD 460 250
CERTIFIED NORSOK M501 rev 5 - System 72 coat
µm
SIGMAZINC 109 HS 100
SIGMASHIELD 420 250
CERTIFIED NORSOK M501 rev 5 - System 1 µm
SIGMAZINC 109 HS 75
SIGMAPRIME 200 200
SIGMADUR 550 50
DeckNew Build & Full Maintenance
TOPSIDES / SUPERSTRUCTURES | 13
SYSTEMS OVERVIEWTopsides / Superstructures
TOPSIDES / SUPERSTRUCTURES | 14
NORSOK system 1 µm
SIGMAZINC 109 HS 75
SIGMAPRIME 200 200
SIGMADUR 550 50
Structural SteelNew Build & Full Maintenance
CERTIFIED ISO 12944-6 C5 High µm
SIGMACOVER 280 50
SIGMACOVER 630 130
SIGMADUR 550 60
Accommodation InternalNew Build & Full Maintenance
CERTIFIED NORSOK M501 rev 5 - System 1 µm
SIGMAZINC 109 HS 75
SIGMAPRIME 200 200
SIGMADUR 550 50
Accommodation ExternalNew Build & Full Maintenance
TOPSIDES / SUPERSTRUCTURES | 15
120°C µm
SIGMAZINC 109 HS 75
SIGMAPRIME 200 200
SIGMADUR 550 50
PipingNew Build & Full Maintenance
120°C - 150°C µm
SIGMAGUARD 730 125
SIGMAGUARD 730 125
New Build & Full Maintenance
150°C - 230°C µm
SIGMATHERM 230 125
SIGMATHERM 230 125
450°C - 540°C µm
SIGMATHERM 540 25
SIGMATHERM 540 25
230°C - 450°C µm
SIGMAZINC 158 75
SIGMATHERM 540 25
TOPSIDES / SUPERSTRUCTURES | 16
120°C µm
SIGMAZINC 109 HS 75
SIGMAPRIME 200 200
SIGMADUR 550 50
Process Equipment ExternalNew Build & Full Maintenance
120°C - 150°C µm
SIGMAGUARD 730 125
SIGMAGUARD 730 125
New Build & Full Maintenance
150°C - 230°C µm
SIGMATHERM 230 125
SIGMATHERM 230 125
450°C - 540°C µm
SIGMATHERM 540 25
SIGMATHERM 540 25
230°C - 450°C µm
SIGMAZINC 158 75
SIGMATHERM 540 25