NO: PC-384 PRODUCT: SYSMAC STUDIO DATE: July 2019 TYPE: Software Update
Sysmac Studio (SYSMAC-SE200D) Version 1.29 Release Note (Contains expanded product capabilities and significant bug fixes)
Updates: Support of New Hardware
Controllers: NJ101/NJ301/NJ501-[]000 Ver. 1.40 NX102-[] []00Ver. 1.40 NX102[][]20 Ver. 1.33 NX1P2 Ver. 1.40 NX701 Ver. 1.21 NY512 Ver. 1.21 NY532 Ver. 1.21 NJ501-1340 Ver. 1.21 NJ501-4[]00 Ver. 1.21 NJ5010-4310 Ver. 1.21 NJ501-5300 Ver. 1.21 EtherNet/IP Connections for: FHV7 Series V430-F Series
Effective July 16, 2019, the following Sysmac Studio software will be updated to Version 1.29. Changes in Version 1.29 are listed below and this update will be available ONLY via Auto Update.
2
Enhanced/Improved Functions
Easier to Make Changes to Functions/Function Blocks
Improved Visibility of Last Rung
3
Axis/Axes groups can be a local variable
IO-Link Master Auto Configuration
4
Drag and Drop IO-Link devices
Use Measured EtherCAT delay for Transmission Delay Time
5
Offline EtherCAT Diagnostics
Offline Access to Event Log
6
Simple to add/delete ESI Files
Easier to Toggle Bits in the Watch Window
7
CIP Safety Monitor Function
Comment Language Switching
8
Improved/Enhanced Functions
Controllers
Solved the problem that system-defined retained variables cannot be selected as targets of variable/memory backup.
Solved the problem that calculation of memory consumption does not progress if string literal of ST contains "(*", but does not contain "*)".
Solved the problem that variables might not be monitored if array variables of zero-padded element numbers and zero-suppressed element numbers are mixed.
Solved the problem that jump to next variable might fail, if there is variation in writing style of element numbers of array variables.
Improved the edit functions of data type editor. Solved the problem that global variables in inline ST might not be copied by
Copy with Dependents. Solved the problem that presence of unassigned task settings cannot be
detected. Solved the problem that variable element comments cannot be applied by
detailed comparison. Solved the problem that change in namespace of data type might not be applied
to other devices, though sharing setting between devices is enabled. Solved the problem that Sysmac Studio might terminate abnormally if Sysmac
Studio is connected online when data in inline ST is invalid. Solved the problem that project download might take long time after definition
of data type is changed. Solved the problem that variable/memory backup might fail in a project that
contains a variable with variable name starting with "String". Solved the problem that focus moves to Watch Tab Page (Table) after definition
of data type is changed. Solved the problem that the graph of trace target variables might not be
displayed if Independent Y Axis Mode is specified for display format of trace result.
Solved the problem that the correct instance might not be monitored in the FB instance monitor when clicking FB on the ladder rung.
Solved the problem that building a ladder rung with multiple rung branches might cause application errors.
HMI Solved the problem that a recipe registered on the NA might not be
uploaded. Solved the problem that images might not be registered when they are
copied and pasted from other projects. Improved so that the corresponding line is displayed when adding a new
resource. Improved uploading performance.
9
Safety Solved the problem that variable names might be displayed as entry options
for data types of published variables. Solved the problem that "F" mark is not displayed correctly in FBD editor
when force-refreshing is performed from Watch Tab Page. Solved the problem that force-refreshing can not be executed from FBD
editor while simulator is running. Solved the problem that focus does not move to the function block name
after an empty function block is added on FBD editor. Solved the problem that a user-defined function block might not be inserted
correctly if the function block was dragged and dropped from the toolbox to FBD editor.
Solved the problem that offline comparison of projects containing safety data might not be executed.
Solved the problem that the external variable comment cannot be edited when the tool option "Use global variable comment" is enabled.
Simulator Solved the problem that the MC_Power instruction is not executed in
simulation of NX102. Solved the problem that Sysmac Studio might be shut down when writing
data by Transfer All Variable Present Values. Drives
Supported adjustment method that tracks the position command in Easy Tuning of 1S-series Servo Drive when one-degree-of-freedom control is specified for Control Method.
Improved so that trajectory error can be displayed in two-dimensional plane in operation check step of Easy Tuning (with multiple Servo Drives)