1 NO: PC-384 PRODUCT: SYSMAC STUDIO DATE: July 2019 TYPE: Software Update Sysmac Studio (SYSMAC-SE200D) Version 1.29 Release Note (Contains expanded product capabilities and significant bug fixes) Updates: Support of New Hardware Controllers: NJ101/NJ301/NJ501-[]000 Ver. 1.40 NX102-[] []00Ver. 1.40 NX102[][]20 Ver. 1.33 NX1P2 Ver. 1.40 NX701 Ver. 1.21 NY512 Ver. 1.21 NY532 Ver. 1.21 NJ501-1340 Ver. 1.21 NJ501-4[]00 Ver. 1.21 NJ5010-4310 Ver. 1.21 NJ501-5300 Ver. 1.21 EtherNet/IP Connections for: FHV7 Series V430-F Series Effective July 16, 2019, the following Sysmac Studio software will be updated to Version 1.29. Changes in Version 1.29 are listed below and this update will be available ONLY via Auto Update.

Sysmac studio v1.29 software update - Omron€¦ · Effective July 16, 2019, the following Sysmac Studio software will be updated to Version 1.29. Changes in Version 1.29 are listed

  • Upload
    others

  • View
    29

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Sysmac studio v1.29 software update - Omron€¦ · Effective July 16, 2019, the following Sysmac Studio software will be updated to Version 1.29. Changes in Version 1.29 are listed

1

NO: PC-384 PRODUCT: SYSMAC STUDIO DATE: July 2019 TYPE: Software Update

Sysmac Studio (SYSMAC-SE200D) Version 1.29 Release Note (Contains expanded product capabilities and significant bug fixes)

Updates: Support of New Hardware

Controllers: NJ101/NJ301/NJ501-[]000 Ver. 1.40 NX102-[] []00Ver. 1.40 NX102[][]20 Ver. 1.33 NX1P2 Ver. 1.40 NX701 Ver. 1.21 NY512 Ver. 1.21 NY532 Ver. 1.21 NJ501-1340 Ver. 1.21 NJ501-4[]00 Ver. 1.21 NJ5010-4310 Ver. 1.21 NJ501-5300 Ver. 1.21 EtherNet/IP Connections for: FHV7 Series V430-F Series

Effective July 16, 2019, the following Sysmac Studio software will be updated to Version 1.29. Changes in Version 1.29 are listed below and this update will be available ONLY via Auto Update.

Page 2: Sysmac studio v1.29 software update - Omron€¦ · Effective July 16, 2019, the following Sysmac Studio software will be updated to Version 1.29. Changes in Version 1.29 are listed

2

Enhanced/Improved Functions

Easier to Make Changes to Functions/Function Blocks

Improved Visibility of Last Rung

Page 3: Sysmac studio v1.29 software update - Omron€¦ · Effective July 16, 2019, the following Sysmac Studio software will be updated to Version 1.29. Changes in Version 1.29 are listed

3

Axis/Axes groups can be a local variable

IO-Link Master Auto Configuration

Page 4: Sysmac studio v1.29 software update - Omron€¦ · Effective July 16, 2019, the following Sysmac Studio software will be updated to Version 1.29. Changes in Version 1.29 are listed

4

Drag and Drop IO-Link devices

Use Measured EtherCAT delay for Transmission Delay Time

Page 5: Sysmac studio v1.29 software update - Omron€¦ · Effective July 16, 2019, the following Sysmac Studio software will be updated to Version 1.29. Changes in Version 1.29 are listed

5

Offline EtherCAT Diagnostics

Offline Access to Event Log

Page 6: Sysmac studio v1.29 software update - Omron€¦ · Effective July 16, 2019, the following Sysmac Studio software will be updated to Version 1.29. Changes in Version 1.29 are listed

6

Simple to add/delete ESI Files

Easier to Toggle Bits in the Watch Window

Page 7: Sysmac studio v1.29 software update - Omron€¦ · Effective July 16, 2019, the following Sysmac Studio software will be updated to Version 1.29. Changes in Version 1.29 are listed

7

CIP Safety Monitor Function

Comment Language Switching

Page 8: Sysmac studio v1.29 software update - Omron€¦ · Effective July 16, 2019, the following Sysmac Studio software will be updated to Version 1.29. Changes in Version 1.29 are listed

8

Improved/Enhanced Functions

Controllers

Solved the problem that system-defined retained variables cannot be selected as targets of variable/memory backup.

Solved the problem that calculation of memory consumption does not progress if string literal of ST contains "(*", but does not contain "*)".

Solved the problem that variables might not be monitored if array variables of zero-padded element numbers and zero-suppressed element numbers are mixed.

Solved the problem that jump to next variable might fail, if there is variation in writing style of element numbers of array variables.

Improved the edit functions of data type editor. Solved the problem that global variables in inline ST might not be copied by

Copy with Dependents. Solved the problem that presence of unassigned task settings cannot be

detected. Solved the problem that variable element comments cannot be applied by

detailed comparison. Solved the problem that change in namespace of data type might not be applied

to other devices, though sharing setting between devices is enabled. Solved the problem that Sysmac Studio might terminate abnormally if Sysmac

Studio is connected online when data in inline ST is invalid. Solved the problem that project download might take long time after definition

of data type is changed. Solved the problem that variable/memory backup might fail in a project that

contains a variable with variable name starting with "String". Solved the problem that focus moves to Watch Tab Page (Table) after definition

of data type is changed. Solved the problem that the graph of trace target variables might not be

displayed if Independent Y Axis Mode is specified for display format of trace result.

Solved the problem that the correct instance might not be monitored in the FB instance monitor when clicking FB on the ladder rung.

Solved the problem that building a ladder rung with multiple rung branches might cause application errors.

HMI Solved the problem that a recipe registered on the NA might not be

uploaded. Solved the problem that images might not be registered when they are

copied and pasted from other projects. Improved so that the corresponding line is displayed when adding a new

resource. Improved uploading performance.

Page 9: Sysmac studio v1.29 software update - Omron€¦ · Effective July 16, 2019, the following Sysmac Studio software will be updated to Version 1.29. Changes in Version 1.29 are listed

9

Safety Solved the problem that variable names might be displayed as entry options

for data types of published variables. Solved the problem that "F" mark is not displayed correctly in FBD editor

when force-refreshing is performed from Watch Tab Page. Solved the problem that force-refreshing can not be executed from FBD

editor while simulator is running. Solved the problem that focus does not move to the function block name

after an empty function block is added on FBD editor. Solved the problem that a user-defined function block might not be inserted

correctly if the function block was dragged and dropped from the toolbox to FBD editor.

Solved the problem that offline comparison of projects containing safety data might not be executed.

Solved the problem that the external variable comment cannot be edited when the tool option "Use global variable comment" is enabled.

Simulator Solved the problem that the MC_Power instruction is not executed in

simulation of NX102. Solved the problem that Sysmac Studio might be shut down when writing

data by Transfer All Variable Present Values. Drives

Supported adjustment method that tracks the position command in Easy Tuning of 1S-series Servo Drive when one-degree-of-freedom control is specified for Control Method.

Improved so that trajectory error can be displayed in two-dimensional plane in operation check step of Easy Tuning (with multiple Servo Drives)